Proper Installation of Insulated Metal Wall Panels

Similar documents
Panel Clip with (2) ¼ 14 x 2 Fasteners at Each Panel Joint. Base Angle. Fasteners to Concrete 24 O/C Base Z Flashing

ELEVATION FOR DETAIL REFERENCE ONLY

Flushglaze For Steel Tube Applications and Horizontal Panels. Façades Installation Guide

12 - V0 CFP-12 PANEL INDEX. Delta Series CONCEALED FASTENED PANELS BUILDING PRODUCTS VERTICAL PANELS

ELEVATION FOR DETAIL REFERENCE ONLY

ELEVATION FOR DETAIL REFERENCE ONLY

FACE CFP - HORIZONTAL PANELS - OPTION 'B'

Regarding the refusal to issue a code compliance certificate for a house constructed with structural insulated panels at 420 Blackrock Road, Masterton

ELEVATION FOR DETAIL REFERENCE ONLY

FACADES - ACM BASE AT OVERHANG (WITH BASE FLASHING) INDEX SHEET

Commercial Flashing Details

Magnum Board Section Digicon Information Inc. Page 1

Maximum thermal performance ISOLEREN INSULATED METAL PANELS INSTALLATION GUIDE

Pebbletex Wall System Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details

Exterior System installation instructions


WEB BASED APPLICATION SPECIFIC INSTALLATION INSTRUCTIONS

SECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system.

Pella 250 Series. Wood Frame Construction with Vinyl Siding... V250-ID-888 Wood Frame Construction with Brick Veneer...

Attachment of Exterior Wall Coverings Through Polyiso to Wood or Steel Wall Framing

KARRIER PANEL - BRICK

Architectural Wall Products Guide Specifications

KNIGHT WALL SYSTEMS GUIDE DETAILS:

KS SERIES - VERTICAL INSTALLATION

Building Envelope Solutions, Inc. Identifying solutions for better building performance

How do you install yours?

Siding and Soffit Installation Guidelines

Building Construction and Water Intrusion

Insulated Metal Panel (IMP) Systems

1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights

ARCHITECTURAL WALL PANELS APPLIED OVER A SHEATHED STUDWALL BY MEANS OF A FIELD ASSEMBLED TEN66 SUB-FRAME SYSTEM

Chapter 2 Understanding The Problem

MR2 SERVICES Site Reconstruction 54 College Street Des Moines, IA

AcroWall-ES System. Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details

Spec Master 5/7/ For each product requiring color and texture selection, provide full size samples.

10 EXTREME BASEMENT PANELS

SRP-AirOutshield UV Issued:

SECTION FABRICATED ENGINEERED STRUCTURES. A. Pre-engineered, shop-fabricated structural steel building with formed purlin framing.

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING

PANEL REPAIRS TECHNICAL BULLETIN Vol FEBRUARY 2017

WATERGATE COMMUNITY ASSOCIATION 8 Captain Drive Emeryville, California Office: / Fax: WINDOW REPLACEMENT GUIDELINES

Installation Instruction 3-D Model 3D 08/04/17. 0 Trespa Pura Siding System N/A WPS, Inc Wall Panel Systems Inc.

7.0 - EXAMPLE DETAILS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: ARCONIC ARCHITECTURAL PRODUCTS, LLC

Fundamentals of Insulated Panel Installation. MBCEA 2016 Clearwater, FL

A. Product Data: For each type of cold-formed steel framing product and accessory.

Vertigo Cladding Board

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

COMPOSITE PANEL SYSTEM SYSTEM OVERVIEW INDEX INSTALLATION SEQUENCE INSTALLATION SEQUENCE INSTALLATION SEQUENCE

ELEVATION FOR DETAIL REFERENCE ONLY

PROPERTY PRESERVATION AND CAPITAL PLANNING

rockspan installation guide horizontally laid panel

Corium Brick Rainscreen System Specifications

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

Product and System Specifications DuPont Flashing Systems

ARCHITECTURAL WALL PANELS APPLIED OVER A SHEATHED STUDWALL BY MEANS OF A FIELD ASSEMBLED RAINSCREEN SYSTEM

ARCHITECTURAL WALL PANELS APPLIED OVER A SHEATHED STUDWALL BY MEANS OF A FIELD ASSEMBLED RAINSCREEN SYSTEM

KNIGHT WALL SYSTEMS GUIDE DETAILS:

A M E R I C A N A R C H I T E C T U R A L M A N U F A C T U R E R S A S S O C I A T I O N

3310, 3315, 3310U, 3315U, 3371 & 3371U Picture Windows

rainspan installation guide horizontally laid panel

CONTOUR CORRUGATED PANEL

WeatherSmart Air Barrier Installation Guide

SECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents.

FMA / AAMA / WDMA Installation Committee Update. Jim Katsaros / DuPont Building Innovations FMA Installation Committee April 24, 2012

All Metals Fabrication AMF FUSION DRILLFREE ALUMINUM COMPOSITE METAL (ACM) WALL PANEL SPECIFICATION

Ameriplate. Rain Screen Wall System

SECTION TERRA COTTA CLAY TILE RAINSCREEN SYSTEM

WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS

HouseWrap Applications System R-Value: R-4.17 Horizontal Heat Flow Only

Exterior Wall Solutions Building Shell


900 SERIES PANEL SHEET INDEX ENDLAP INSTALLATION SEQUENCE L.E. W/ GUTTER VAPOR BARRIER CS-RK-01B-900

Siding and Soffit Installation Guidelines

ELEVATION FOR DETAIL REFERENCE ONLY

WEIGHT PER PIECE (LBS.)

Magnum Board Coatings

On Cold-Formed Steel Construction. Light Gauge Steel Engineers Association Washington, D.C Toll Free (866)

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

EIFS Rain Control EIFS. Face Sealed Perfect Barrier. Beware of EIFS: They must be done correctly They leak at joints Avoid moist sensitive substrate

BEARING METAL STUD FRAMING

Guide Specification for the OSI QUAD Window and Door Flashing System

Architectural Roof Products Guide Specifications

SC-01 Cross-Section. Cement Board Substrate Master Wall Mesh and Base Coat Superior Finish

The better way to build TM. Installation Manual NAILBASE PANELS

Installation Guidelines

INSTALLATION MANUAL. ZIP System R12 Sheathing. Contents. 07 ZIP System R12 Sheathing Window Installation 08 ZIP System R12 Sheathing Siding Guidelines

Arcwall. Rain Screen Wall System

Primary Concerns and Defects

Code Compliance Research Report CCRR-0228

TABLE OF CONTENTS. 1.0 INTRODUCTION 1.1 Greenstone Structural Engineered Panels 1.2 Drawing and Element Numbers

Issue Date: April 2003 Release: I. Product Specifications

WEB BASED APPLICATION SPECIFIC INSTALLATION INSTRUCTIONS

SURESILL WATER MANAGEMENT GUIDE

PROJECT TITLE PROJECT NO: CONTRACT TITLE GRANT NO: UNIVERSITY OF CALIFORNIA, DAVIS DAVIS, CALIFORNIA

Roof Replacement. Notes: T-1 (Title Sheet) Roof Key Plan Russell House Student Union 1400 Greene Street Columbia, South Carolina 29208

TerraClad TM General Specifications

PART 1 / GENERAL SECTION ALUMINUM PLATE PANEL SYSTEM. ALPLY Insulated Panels. Alply TECH WALL Aluminum Plate System 2002

Limited Leak Assessment

Insulated Concrete Forms (ICFs)

Transcription:

Proper Installation of Insulated Metal Wall Panels Insulated metal panels (IMPs) are an ideal cladding solution for pre-engineered metal buildings. They are available in lengths up to 50, and may also incorporate stack joint conditions for taller buildings. Panel thicknesses are from 2 through 6, with excellent R values of approximately 7.5 per inch. The key considerations when using IMPs with pre-engineered metal buildings are as follows: Structural alignment IMPs are fairly flexible, but not as flexible as single skin cladding. Typical structural alignment for vertically installed panels requires that wall girts be ± 1/8 in 5 feet in any direction along plane of framing, ± 3/8 in 20 feet cumulative in any direction along framing plane and ± ¾ from the framing plane on any elevation. In addition, panel supports must extend to the outer extremities at all panel terminations. 1-800-486-8415 info@steelbuildinginsulation.com www.steelbuildinginsulation.com

Failure to properly align structural components to these tolerances can result in numerous issues including: Difficulty in engaging panels upon attachment, panels will follow the contour of the girt system. As the next panel is hoisted into place, engagement can become difficult or nearly impossible as the original panel is now shaped by structural misalignment. This typically leads to the installer resorting to unapproved methods of forcing subsequent panels to conform to the misalignment, such as Banging on panels with mallets, hammers, wood blocking etc. Using come alongs to force engagement Using excessive torque on clip fasteners trying to force panel to contact supporting structural members. Each of these improper techniques can result in long term panel damage, including delamination, thermal blistering and panel kinks. Properly aligned secondary assures that panels will engage easily and without undue force, and will result in the best possible aesthetic for the panel (flat and with a minimum of visible distortion). There are several different details available for base conditions: Base details When designing panel alignment vs. slab edge, it is good to remember a basic principle of insulated panels. In commercial/industrial applications, the exterior panel joint serves as a wall drainage channel. In other words, it carries water via gravity down the panel system and out at the bottom of the wall. Bypass Condition: Bypass Condition: outside flange of wall girts are aligned with outside edge of slab. This allows the panels to be outboard of the slab at the base, and provides the most effective way to drain wall system water out and away.

Notched Slab Notched slab is where the concrete slab is constructed with a key way. This requires the use of back-flashing to drain water from the exterior joint out and away from the wall to Flush Condition Flush Condition is where the wall girts are inset the thickness of the panels, so that the outside face of the panels is flush with the slab edge.

All base details are sensitive to the proper placement of butyl sealant. In particular, non-skinning butyl sealant must be placed at the following areas: Between the vertical back leg of the Z flashing or base support and the interior face of the panel (all base details) Between the horizontal slab surface and the underside of the Z flashing to prevent wind driven rain from entering the building (notched slab and flush condition details) Between the base angle/support and concrete slab (overhang detail) Lap conditions for all Z flashings (2 rows of sealant recommended) Finish Grade Care must be taken to ensure that the base detail chosen is compatible with finish grade. The photo below shows an improper base condition, where the bottom of the panels are covered up by concrete. This poses several problems: Drainage is blocked from the exterior panel joint, causing water to build up within the joint. This particular situation resulted in leaks to the interior of the building. The metal skins of the panel are not designed to be below grade. This will lead to premature corrosion of the panel skins and associated paint system failure.

Window Details Proper trim installation is essential to prevent leaks at window areas. Typical trim details use two piece trims for head and jambs, and one piece trim for sill conditions. It is critical that the interior portion of the two piece trims be installed prior to the installation of wall panels. Non-skinning butyl sealant must be placed between the vertical legs of the interior trims and the supporting structural C girts to prevent wind driven rain from entering the opening. In addition, sealant must be placed between the vertical leg of the interior trims and the backside of the panels to prevent both water intrusion Each end of the one piece sill trim should employ field bent tabs (bent upwards) before installing the outer jamb trims. Then, seal the juncture of the sill and jamb trims with exposed sealant (typically silicone or urethane).

Following these simple guidelines should help you enjoy the benefits of insulated metal wall panels for the life of your building. 1-800-486-8415 info@steelbuildinginsulation.com www.steelbuildinginsulation.com