AN ASSESSMENT OF ENERGY AND EMISSIONS PERFORMANCE OF BUILDINGS AT TEACHERS MUTUAL BANK LTD

Similar documents
CAPABILITY STATEMENT SUSTAINABILITY ADVISORY SERVICES CLEAN ENERGY. CORPORATION AUSTRALIA

Emission Inventory Report. For the period 1 July 2006 to 30 June 2007

Building Upgrade Finance No worse off Methodology for Estimating Tenant Cost Savings 1

Westpac Banking Corporation.

Energy Innovation in the ACT

Energy Policy 2013 Annual Update

Carbon Footprint and Project Register Training

GLOBAL SUSTAINABILITY FRAMEWORK FY16 ENVIRONMENTAL DATA (ENERGY, EMISSIONS, WATER, WASTE & NORMALISATION DATA) AND SUMMARY BASIS OF PREPARATION

CARBON NEUTRAL PROGRAM PUBLIC DISCLOSURE SUMMARY Carbon Neutral Program

ENERGY EFFICIENCY OPPORTUNITIES REPORT July June 2012

CLIMATE CHANGE REQUIRED REPORTING CORPORATE EMISSIONS, TARGETS AND PROJECT DATA. 1 st September 2015

Strategies for measuring and reducing your carbon footprint

Carbon Management Plan Keele University

Marks and Spencer Group Plc. PAS 2060:2014 Specification for the demonstration of carbon neutrality

Not Protectively Marked. Scottish Ambulance Service September 2012 SUSTAINABILITY REPORT

Corporate Emissions Assessment Protocol

KPI METHODOLOGY DOCUMENT

PAS 2060: 2014 specification for the demonstration of carbon neutrality

1. Organisation and Product Information

2011 & 2012 Queen s University Greenhouse Gas (GHG) Inventory

Summary of Net Metered Projects as of June 30, Small Net Metered Projects as of 6/30/2016 Small Group Host Projects as of 6/30/2016

Greenhouse Gas Assessment

AGL Future Forests Program. Annual Report FY17

Energy Policy 2015 Annual Update

Small-scale technology certificates Data modelling for 2018 to 2020

Environmental excellence

included Included in FTSE4Good Index Carbon emissions (CO 2 Carbon Disclosure Project performance band FTSE Russell/JSE Responsible Investment Index

SOLAR REPORT JANUARY 2018

City of Carson City 3505 Butti Way Carson City, NV PUBLIC WORKS SOLAR PV SYSTEM PROJECT EXECUTIVE SUMMARY

Sustainability Report

Renewable Energy Index. December 2017

Greenhouse Gas Assessment

Reporting criteria for selected key performance indicators in the 2016 Responsible Business Reporting

Solar Program Design Study

SEGRO Methodology for Greenhouse Gas Reporting

Greenhouse Gas Assessment

QUEEN S UNIVERSITY GREENHOUSE GAS EMISSIONS INVENTORY SUMMARY 2015

SOUTH DUBLIN COUNTY COUNCIL ENERGY REVIEW

Re: Victorian Transitional Feed-in Tariff (TFiT)

Allens FY 2013/14. Page 1/8

WM2012 Conference, February 26 March 1, 2012, Phoenix, Arizona, USA. Hanford Site Sustainability Program, Richland, Washington 12464

Climate Change: Portfolio Analysis Views after Paris. Dr Fiona Wild Vice President, Sustainability & Climate Change

BBC ENVIRONMENTAL SUSTAINABILITY. Targets and performance 2017/18

Autonomous Energy Presentation to the ESSSN August 2014

A Holistic Approach to Energy Management Presented by Ari Kobb Manufacturing in America March 14-15, 2018

Supporting Documentation A Changing Industry and Marketplace 0

JTP 2016 carbon footprint

Renewable Energy Index. February 2018

Renewable Energy Index Benchmark Report

FOR MANAGING AND REDUCING THE

SSE s criteria used for GHG emissions reporting

Power Retail Corporation (Trading as Jacana Energy) Statement of Corporate Intent Public Version

CARBON FOOTPRINT REPORT

Renewable Energy Index. January 2018

The German solar rooftop experience Applicability in the Indian context. Indo-German Development Cooperation June 7 th, 2016

GREENHOUSE GAS EMISSIONS AND ENERGY USE ANNUAL REPORT

Amer Sports Carbon Footprint 2015

LENDLEASE CORPORATION GLOBAL SUSTAINABILITY FRAMEWORK

LOCAL GOVERNMENT PARTNERSHIP CITY OF BEAUMONT

THE VOLUNTARY CARBON OFFSET MARKET IN AUSTRALIA

3.2 Energy efficiency and renewable energy

Renewable Energy Index. October 2018

ENERGY MANAGEMENT PLAN JUNE UPDATED OCTBER 2017.

Introduction. Harrow College Carbon Footprint. Calendar Year 2017

33% 25% 17% 17% Energy and Carbon Management Strategy. Site electricity. Business travel and commuting. Vans. Site gas. Office electricity.

Unlock new value from your property

Carbon Reporting & Footprinting. Jean Lowes

CARBON FOOTPRINT PHILIPPINES :: MALAYSIA :: VIETNAM :: INDONESIA :: INDIA :: CHINA

Fact sheet. Photovoltaic systems. Why consider photovoltaics?

Renewable Energy Index. April 2018

THE 2012 JOHNS HOPKINS UNIVERSITY GREENHOUSE GAS REPORT

Global Wind Power; Wind Power opportunities in Australia; Why Wind Power for Australia? Wind Power for Australia. Wind Power environmental impacts;

The NGER Act underpins the current carbon pricing scheme by collating Australia s greenhouse gas emissions data.

Scope 2 Accounting Guidance: What it means for corporate decisions to purchase environmental instruments - January 2015

AEP Ohio. Combined Heat and Power (CHP) May 24 th, 2017 Steve Giles Vice President Alternative Energy Hull & Associates, Inc.

Carbon Neutrality Action Plan

Conservation and Demand Management Plan

QUEEN S UNIVERSITY GREENHOUSE GAS INVENTORY REPORT 2017

2012 Business Carbon Footprint (BCF) Report Commentary & Methodology. Clive Steed Head of Environment, Sustainability & Public Safety

Executive Order (EO) EO 13423, Strengthening Federal Environmental, Energy, and Transportation Management, Signed by President Bush on January 2

Coenraad Pretorius Energy Engineer Anglo American South Africa

Coenraad Pretorius Energy Engineer Anglo American South Africa

Education Services Australia Limited ENVIRONMENT REPORT

Public Sector Climate Change Duties 2016 Summary Report: The Scottish Children's Reporter Administration. Required TABLE OF CONTENTS

25,000. Energy use in Uralla Town and Shire. The energy context. MEGAwatt hours. Firewood in Uralla 45% Uralla's Electricty GRID

Scope 3 Emissions Reporting for Tertiary Education. Chris Wilson, Pangolin Associates Carmen Primo, University of Tasmania

GREENHOUSE GAS EMISSIONS AND ENERGY USE ANNUAL REPORT

IS THE SUN SETTING ON LOCAL GOVERNMENT SOLAR PROJECTS?

Carbon Management Plan. Executive Summary

THE ZERO ENERGY POOL SOLAR ELECTRICITY + POOL HEATING NATIONAL

Carbon Neutral Program Public Disclosure Summary

There is no duty on municipalities in the UK to manage or reduce CO 2 emissions.

Business Carbon Footprint 2016/17

TELUS Greenhouse Gas. Report

6/29/2017. Carbon Neutral Approach of Delhi Airport. GreenCo Platinum Certified Company. 23 rd June, 2017

SOLAR REPORT QUARTER 3, 2018

Voluntary Renewable Energy Markets 101

The White Certificate Scheme in New South Wales, Australia

Carbon Management Plan

National Carbon Offset Standard Public Disclosure Summary

Transcription:

AN ASSESSMENT OF ENERGY AND EMISSIONS PERFORMANCE OF BUILDINGS AT TEACHERS MUTUAL BANK LTD AUGUST 2016

Overview Teachers Mutual Bank Ltd, which includes Teachers Mutual Bank and Unibank, has invested significantly in improving the environmental performance of its buildings, which are the largest source of its direct environmental footprint. This report provides an assessment of the environmental credentials of the bank, with a focus on electricity and greenhouse gas (GHG) emissions and reduction measures in buildings over the past five years. The main measures are Solar PV installations and LED lighting upgrades. Teachers Mutual Bank Ltd currently owns premises at four locations: Homebush, Rooty Hill, Parramatta and Perth. These sites account for over 90% of Teachers Mutual Bank Ltd s emissions from buildings. The bank operates out of a further four rented premises and is limited in its ability to implement emissions reduction measures at these sites. As such, the focus of this assessment is on the owned sites. The bank s broader GHG footprint (leased sites and vehicles) has also been reviewed to put the performance of owned buildings in context. Since 2013, Teachers Mutual Bank has been a carbon neutral organisation with zero net emissions. 2

Highlights Since 2011, Teachers Mutual Bank s emissions from owned buildings has reduced by 16%, or 3.3% a year on average. Installations of 612 solar PV panels and 1,826 LED lights are on track to reduce building emissions by a further 28%. 186kWp of solar PV installed on all 4 owned buildings. The 186kWp represents a near 80% increase in known PV capacity in the banking sector in Australia, from 240kWp to 426kWp. Two of the sites will also export solar power to the grid. Solar PV installed at the Unibank Perth office is forecast to generate 40% of its electricity use. The LED lighting upgrades on 3 owned buildings reduces electricity consumption from lighting by 68%. Combined the Solar PV installations and LED lighting upgrades represents: Total investment cost of $454,467 Annual cost savings of $148,899 Electricity savings of 557,083 kwh p.a. Emissions savings of 462 tco 2 -e p.a, or 28% of the total Over the next 5 years, Solar PV and LED is forecast to save $744,493 in costs and 2,306 tco 2 -e of emissions Since 2013, Teachers Mutual Bank has been a carbon neutral bank, offsetting all emissions from vehicles and buildings (Scope 1 and 2 emissions). Since 2011, Teachers Mutual Bank has increased its economic activity (+38% assets) while reducing emissions (-16%). Therefore emissions intensity reduced by 39% from 0.54 to 0.30 tco 2 -e per million $ of assets. The impact of PV and LED lighting upgrades will improve this significantly. From October 2016, Teachers Mutual Bank Ltd will have solar PV and LED lighting installed at all four of its owned buildings. 3

Emissions and energy footprint Teachers Mutual Bank Ltd s energy and emissions footprint is created through both Scope 1 and Scope 2 emissions. Scope 1 emissions are direct emissions generated through the use of fuel in staff vehicles while Scope 2 emissions are indirect emissions generated through the consumption of electricity in buildings owned or rented by Teachers Mutual Bank. This assessment is considering both Scope 1 and 2 emissions for the five year period between FY 2011 and FY 2015: In FY 2011 and 2012, Teachers Mutual Bank only measured emissions from owned and leased buildings (Scope 2) From FY 2013, emissions from staff vehicles (Scope 1) were also measured Since FY 2013, Teachers Mutual Bank has purchased carbon offsets for all Scope 1 and 2 emissions and has been a carbon neutral bank The number of buildings occupied has increased to seven sites, and the addition of the UniBank Perth office in July 2015 mean that the Bank has occupied eight sites from FY 2016 The rollout of main emissions reduction measures (Solar PV installations and LED lighting upgrades) will be completed by October 2016 and so cost and emissions savings do not appear in the FY 2011 2015 data set. In FY 2015, the total GHG emissions for Teachers Mutual Bank were 2,389 tonnes CO 2 -e. This was comprised of: 638 tco 2 -e from fuel use in vehicles (Scope 1 emissions) 1,751 tco 2 -e from electricity consumption in buildings (Scope 2 emissions) Of the 1,751 tonnes of Scope 2 emissions, 1,600 (91%) were generated from buildings owned by Teachers Mutual Bank in Homebush, Rooty Hill and Parramatta (NSW) 1. 150 9% 1,751 tco2-e TMB leased buildings TMB owned buildings 1600 91% Figure 1 - Teachers Mutual Bank absolute GHG emissions from buildings for FY 2015 1 The Perth Unibank office was acquired in July 2015 so data has not been included in Teachers Mutual Bank s emissions and electricity footprint for FY15 but has been included in data projections going forward 4

Annual GHG emisshions (tco2-e) Annual GHG emissions (tco2-e) As Figure 2 illustrates, emissions from electricity consumption at owned buildings have been mostly consistent the past three years, and have decreased by 16% since the baseline year of FY 11 to 1,600 tco 2 -e. 2,000 1,500 1,000 1,913 1,510 1,642 1,689 1,600 500-2010 -11 2011-12 2012-13 2013-14 2014-15 Figure 2 - Emissions from owned buildings for FY 11-15 The overall decrease over the past five years is despite the expansion into a new office in Parramatta for FY 14 and FY 15, which increased the total despite decreased electricity consumption at the other two sites in those years. At the two main sites of Homebush and Rooty Hill (which represent 90% of total emissions), emissions have dropped by 25% from 1,913 to 1,436 tco 2 -e. This is displayed in Figure 3 below. 2,000 407 1,500 359 403 204 387 164 401 New Parramatta office 1,000 Rooty Hill 500 1,506 1,151 1,238 1,099 1,035 Homebush - 2010-11 2011-12 2012-13 2013-14 2014-15 Figure 3 Annual GHG emissions, by owned office 5

Emissions reduction and carbon neutrality Emissions reduction measures In 2015 and 2016, Teachers Mutual Bank Ltd has invested in two significant measures to reduce the emissions associated with its largest source of emissions, building electricity consumption: 1. Solar Photovoltaic (PV) panels installed on all of its 4 owned buildings (Homebush, Rooty Hill, Parramatta, Unibank Perth) 2. LED lighting replacement at 3 of its owned buildings (Homebush, Rooty Hill, Perth) The Bank has also invested in emissions reductions previously: In 2014, the Parramatta office was fitted with LED lights. This involved replacing 469 lamps at a net cost $16,718. The replacement has been estimated at reducing annual lighting electricity consumption by 26% and nearly $18,000 in annual electricity and maintenance savings, which means a payback period of less than 1 year. In 2013, the Bank invested in a Long Range Holden Volt, a battery powered electric car with on board generator. As part of fleet use, Teachers Mutual Bank employees have driven the Volt over 17,000 km, saving up to 1,800 litres of petrol consumption and 4 tonnes of emissions. The combined measures are forecast to reduce Teachers Mutual Bank Ltd s total annual emissions by 28% from owned buildings (462 tco 2 -e) in FY 2017 and the remaining amount is offset through carbon credits. This breakdown is illustrated in Figure 4 and the Solar PV and Lighting upgrade impacts are explored below. 100.0% 14.2% 13.4% 72.4% Total emissions (FY 15) Lighting upgrades Solar PV Offsets Figure 4 - Contribution of emissions reduction measures and offsets projected per annum (based on FY 15 figures) 6

Solar PV installations Teachers Mutual Bank Ltd has worked with AGL to install a total of 612 solar PV panels across its 4 owned premises. The total cost was $400,000 and once small-scale technology certificates are included, the net price of the installations is $239,000 2. This investment totals a peak power of 186 kw and is estimated to generate up to 270,000 kwh per annum as set out in Table 1. Two of the systems will also export up to 6,500 kwh to the grid annually. Three installations have been completed during FY 2016, with the Unibank WA office expected to be on line by October 2016. Table 1 - Solar PV installation overview, by site Peak power (kwp) Number of panels Est. annual generation (kwh) Est. annual export (kwh) Gross system cost ($) Net system cost (w/ STC rebate) Site Total for owned sites 186 612 270,100 6,520 $397,236 $239,003 Homebush, NSW 80.3 259 126,000 - $169,667 $101,942 Rooty Hill, NSW 58.3 188 71,000 - $118,632 $69,516 Parramatta, NSW 24.5 79 34,500 1,296 $47,250 $26,615 Perth, WA Unibank 22.4 86 38,600 5,224 $61,687 $40,930 Teachers Mutual Bank Ltd s solar PV installation means it will have solar power at all owned building sites and Figure 5 demonstrates the proportion of electricity consumption from solar generation expected at each site. Perth, WA 40% Parramatta, NSW 18% Rooty Hill, NSW 15% Homebush, NSW 10% Total for TMB owned buildings 14% 0% 20% 40% 60% 80% 100% Solar PV generation Total electricity consumption Figure 5 - Proportion of annual electricity consumption from solar PV generation (based on FY15 electricity consumption) The solar PV installations are forecast to reduce up to 224 tco 2 -e of emissions annually, which is approximately 13% of Teachers Mutual Bank Ltd s total emissions. Additionally, the installations will result in up to $41,000 of savings in annual electricity costs. Therefore, the total installations have a simple payback of approximately 5.9 years, although this varies per site as shown in Table 2. 2 This is the net system cost after small-scale technology certificates (STCs) from the Renewable Energy Target are taken into account, which result in an estimated rebate of $158,233 7

Table 2 - Annual emissions and cost savings from solar PV installation, by site Annual emissions avoided (tco 2e) Annual cost savings* Expected payback Site Total for owned sites 224 $40,739 5.9 Homebush, NSW 106 $17,849 5.7 Rooty Hill, NSW 60 $7,391 8.8 Parramatta, NSW 29 $5,572 4.8 Perth, WA Unibank 29 $9,927 4.1 *Based on current retail price of electricity for Teachers Mutual Bank Ltd and estimated performance of system LED lighting upgrades Teachers Mutual Bank Ltd commissioned Ilum-A-Lite to replace a range of fluorescent, halogen and HID lighting at three of its owned sites, with more efficient LED lighting. A total of 2,938 lamps will be replaced with 1,826 LED installations at Homebush, Rooty Hill and Unibank Perth for a net capital investment of $215,000 3. These upgrades are expected to reduce lighting electricity usage at these sites by between 60-70%. For Teachers Mutual Bank and Unibank, the upgrades will reduce annual electricity consumption by up to 287,000 kwh, or 14% of Teachers Mutual Bank and Unibank s total annual consumption at owned sites. This is explored in Table 3 and Figure 6 below. Table 3 - LED lighting upgrade projected electricity savings, by site (based on FY 15 data) Current lighting electricity usage per annum (kwh) Lighting electricity saving per annum (kwh) Reduction in lighting electricity usage per annum (%) Total electricity usage per annum (kwh) Total electricity saving per annum (kwh)* Total electricity saving per annum (%) Site Total for 377,344** 256,434 68.0% 2,000,509 286,950 14.3% owned sites Homebush, 265,379 183,893 69.3% 1,231,902 205,727 16.7% NSW Rooty Hill, NSW 56,323 33,572 59.6% 477,510 38,199 8.0% Perth (Unibank) 55,642 38,969 70.0% 95,627 43,024 45.0% *Includes A/C savings at a conservative estimate of 15% of lighting electricity savings ** Based on 3 sites listed here, Parramatta office lighting electricity usage not known 3 This is the net capital cost after rebates from the NSW Government s Energy Savings Scheme (ESS) are included, which are estimated at $24,314 8

Unibank Perth 16,673 55,642 Current lighting electricity usage per annum (kwh) Future lighting electricity usage per annum (kwh) Rooty Hill 22,751 56,323 Homebush 81,486 265,379 Total for 3 sites 120,910 377,344 Figure 6 - Annual savings in lighting electricity consumption from LED lighting upgrades, by site The LED lighting upgrades are expected to reduce up to 238 tco 2 -e of emissions annually, equivalent to 14% of Teachers Mutual Bank Ltd s total emissions from owned buildings. Additionally, the installations will result in up to $108,000 of savings in annual electricity bills and maintenance costs. Therefore, the total installations have an expected simple payback of approximately 2 years, although this varies per site as shown in Table 4. Table 4 - Annual emissions and cost savings from LED lighting upgrades, by site Annual emissions avoided (tco 2e) Annual emissions avoided (%) Total annual cost savings* Capital investment (after rebates) Expected payback 238 14.3% $108,160 $215,464 2.0 Site Total for owned sites Homebush, NSW 173 16.7% $84,493 $148,258 1.8 Rooty Hill, NSW 32 8.0% $9,546 $29,658 3.1 Perth, WA (Unibank) 33 45.0% $14,121 $37,548 2.7 *Includes electricity costs (using current retail electricity price for Teachers Mutual Bank Ltd) and maintenance costs (based on expected failure rates and replacement costs for existing lamps Carbon neutrality Since July 2012, Teachers Mutual Bank has been a carbon neutral bank that offsets GHG emissions from Scope 1 and 2, electricity and fuel use. Teachers Mutual Bank has invested in three carbon offset projects in Asia- Pacific that have robust social, environment, community and education credentials. The offset supplier is Climate Friendly. As part of its emissions calculations and offsets, Teachers Mutual Bank undertakes two Greenhouse Gas (GHG) accountancy processes: 1. A GHG emissions inventory that creates a financial accounting system for our organisational GHG emissions under our operational control. 2. An assurance audit that provides an independent, expert assessment and verification of our Inventory, and verification of our claims of carbon neutrality. 9

Future performance Both the solar PV installation and LED lighting upgrades will have ongoing environmental and financial benefits. While the expected lifespans for both installations are 20+ years, projections have been made for the next five years in this section. As Table 5 demonstrates, Teachers Mutual Bank Ltd will save nearly $204,000 in electricity bills and avoid over 1,100 tonnes of emissions over five years from the solar PV installations. Table 5 Five year forecast of emissions and cost savings from solar PV installation, by site Emissions avoided over 5 years (tco 2e) Site Annual cost savings Cost savings over 5 years* Total for owned sites $40,739 $203,694 1118 13% Homebush, NSW $17,849 $89,245 529 10% Rooty Hill, NSW $7,391 $36,955 298 15% Parramatta, NSW $5,572 $27,860 145 18% Perth, WA (Unibank) $9,927 $49,634 147 40% *No cost escalation assumed Emissions avoided over 5 years (% of total emissions) Similarly, Teachers Mutual Bank Ltd will save over $540,000 in electricity and maintenance bills and avoid nearly 1,200 tonnes of emissions over five years from its LED lighting upgrades as indicated in Table 6. Table 6 Five year forecast of emissions and cost savings from LED lighting upgrades, by site Emissions avoided over 5 years (tco 2e) Site Annual cost savings Cost savings over 5 years* Total for owned sites $108,160 $540,799 1188 14% Homebush, NSW $84,493 $422,464 864 17% Rooty Hill, NSW $9,546 $47,729 160 8% Perth, WA (Unibank) $14,121 $70,606 163 45% *No cost escalation assumed Emissions avoided over 5 years (% of total emissions) Over the five years from FY 2011 2015, Teachers Mutual Bank reduced emissions from owned buildings by 16%, an average of 3.5% per annum. The lighting upgrades and solar PV installations together mean that Teachers Mutual Bank Ltd will generate 28% fewer emissions from its owned buildings per year, compared to 2015. Table 7 Combined Solar PV and LED Lighting upgrade data, annual and 5 year forecast Solar PV LED Lighting Total Number of installations 612 panels 1826 lights - Investment cost $239,003 $215,464 $454,467 Annual cost saving ($) $40,739 $108,160 $148,899 Annual electricity savings (kwh) 270,133 286,950 557,083 Annual emissions savings (tco 2-224 238 462 e) 5 year cost savings ($) $203,694 $540,799 $744,493 5 year electricity savings (kwh) 1,350,666 1,434,750 2,785,416 5 year emissions savings (tco 2-e) 1,118 1,188 2,306 10

Emissions (tco2-e) Over the next five years, Teachers Mutual Bank Ltd would generate 8,364 tonnes of gross emissions without the upgrades. The Bank is now forecast to generate 6,058 tonnes of gross emissions, which will be offset. This is shown in Figure 7. 9,000 8,000 8,364 7,000 6,000 6,058 5,000 4,000 3,000 2,000 1,000 - Total emissions over 5 years without lighting upgrades or Solar PV installations Total emissions over 5 years with lighting upgrades and Solar PV installations Figure 7 - Total owned building emissions avoided from LED upgrades and solar PV installations - 5 year forecast 4 Solar PV in context The Bank s total solar PV installation is one of 26 medium-scale installations 5 commissioned in Australia in 2015. The installation represent 2.3% of the total output capacity of all medium-scale installations for 2015 6. According to solar energy consultants Sunwiz and a review of publically available information, Teachers Mutual Bank Ltd s solar PV installation represents an 80% increase known solar PV capacity in the banking sector in Australia (from 240 kwp to 426 kwp). 240 kwp 185 kwp TMB All other known banking sector Figure 8 - Installed solar PV capacity in the banking sector (as of July 2016) There are six other known installations in the banking sector and Teachers Mutual Bank Ltd s are also the first known solar PV installations in the banking sector in NSW. 4 The 5 year emissions forecast is based on the FY15 emissions data and assumes that emissions will remain the same each year. While emissions may not remain static, the quantum of emissions avoided from the lighting upgrades and solar PV installations will remain the same over 5 years, regardless of actual emissions produced. The UniBank solar PV is due on line in September 2016 5 Medium scale installations refer to systems between 100 kw to 1 MW 6 Clean Energy Council (2016) Clean Energy Australia Report 2015 11

Emissions intensity (tco2-e / $m assets) Emissions intensity Teachers Mutual Bank s emissions reductions can placed in context by considering the intensity of emissions, i.e. the rate of change in emissions relative to another activity. It is common practice for organisations to track their absolute emissions but tracking their relative emissions over time enables both an understanding of how emissions have changed in line with business activity and comparison across organisations of varying size and complexity. At an international level, for example, it is accepted practice for countries to use emissions per unit of GDP as an intensity metric. If GDP grows faster than emissions, this suggests that there are efficiency improvements in terms of emissions generated relative to economic activity. Over the past five years, Teachers Mutual Bank has increased its economic activity each year while reducing emissions. Compared to 2011, Teachers Mutual Bank has increased its total assets by 38% while reducing its underlying emissions from owned buildings by 16%. 5,000 4,000 3,522 total assets ($m) 3,768 4,089 GHG emissions (tco2-e) 4,394 4,862 3,000 2,000 1,000 1,913 1,510 1,642 1,689 1,600 0 2010-11 2011-12 2012-13 2013-14 2014-15 Figure 9 GHG emissions from owned buildings compared to assets, by year In other words, Teachers Mutual Bank has lowered its emissions intensity by 39% from 0.54 to 0.30 tco 2 -e per million $ of assets. 0.60 0.54 0.40 0.40 0.40 0.38 0.33 0.20-2010 -11 2011-12 2012-13 2013-14 2014-15 Figure 10 - GHG emissions intensity, by year 12

Annual GHG emissions (tco2-e) Annual GHG emissions (tco2-e) Total Greenhouse Gas (GHG) footprint - All buildings and vehicles While this assessment has focused on the emissions footprint and reduction measures associated with Teachers Mutual Bank s owned buildings and Teachers Mutual Bank is carbon neutral, the total GHG footprint has also been analysed. As Figure 11 illustrates, Teachers Mutual Bank s Scope 1 and 2 emissions from all buildings (owned and leased) and vehicles increased marginally (0.6%) in FY 15 compared to the previous year. 2,500 2,000 152 536 536 638 1,500 197 148 150 150 Vehicles 1,000 1,913 1,510 1,642 1,689 1,600 Leased buildings 500 Owned buildings - 2010-11 2011-12 2012-13 2013-14 2014-15 Figure 11 - Total GHG emissions for FY 11-15, by source The main driver for this was an increase in vehicle emissions, despite a decrease in emissions from buildings. Over the past five years, Teachers Mutual Bank s total emissions from all buildings has decreased by 15%, despite the number of offices occupied increasing from 5 to 7 over that period. 2,500 7 2,000 1,500 5 5 5 6 1,000 1,913 1,510 1,642 1,689 1,600 500-2010 -11 2011-12 2012-13 2013-14 2014-15 Owned buildings Leased buildings Total number of offices Figure 12 - Annual emissions for all buildings 13

Report preparation This report has been prepared by The Incus Group and is based on audited data provided to The Incus Group directly by Teachers Mutual Bank Ltd and data provided by its suppliers, Ilum-A-Lite and AGL. Teachers Mutual Bank Ltd includes Unibank and Teachers Mutual Bank. Since July 1 2015, UniBank is a division of Teachers Mutual Bank Ltd. Prior to that, the data refers to Teachers Mutual Bank only. All analyses were performed on this data as made available in August 2016 and no verification was undertaken. The greenhouse gas emissions data reported here for Teachers Mutual Bank Ltd are based on Scope 1 and 2 emissions. All GHG emissions data was normalised using FY 2015 emissions factors from the Department of the Environment s National Greenhouse Account Factors to show real changes in emissions, accounting for changes in emission factors. This report was prepared in accordance with the scope of work agreed with Teachers Mutual Bank Ltd and is based on generally accepted practices and standards at the time it was prepared. About The Incus Group The Incus Group is a purpose-driven consultancy that guides organisations through the life cycle of understand, measuring and managing their impact. Our expertise extends from the development of strategy through to impact measurement and capacity building and we seek to work with organisations to measure what matters and convert best intentions into successful outcomes. 14 E info@theincusgroup.com W theincusgroup.com L linkedin.com/company/the-incus-group