Southwest Clean Air Agency NE 99 th St, Suite 1294, Vancouver, WA 98682

Similar documents
GENERAL TESTING AND REPORTING REQUIREMENTS

Alabama Department of Environmental Management Air Division Planning Branch Emission Measurement Section

Guidance for Portable Electrochemical Analyzer Testing Used for Compliance Monitoring

ROP - CAM EXAMPLE TABLE NOTE: THIS TEMPLATE IS NOT AN OUTLINE FOR A CAM PLAN

Air Division. Emissions Test Protocol And Test Report Requirements

TEST REPORT. EVALUATION CENTER Intertek Testing Services NA Inc Murphy Drive Middleton, WI 53562

Comparison of Dry Sorbent Injection of Sodium Bicarbonate, Lime, and Carbon and Their Control of Dioxins/Furans, Mercury, Chlorides and Sulfur Dioxide

TEST REPORT SCOPE: EMISSIONS, EFFICIENCY AND OUTPUT FUEL: EPA TEST FUEL (CRIBS) TEST STANDARD: EPA MODEL: SOLUTION 2.

TEST REPORT. REPORT NUMBER: MID-001b REPORT DATE: November 10, 2016

State of New Hampshire Department of Environmental Services Air Resources Division. Temporary Permit

Common CEMS RATA Failures and Risks. Paula Metz Alliance Source Testing, LLC Technical Services Assistant Manager

METHOD 17 PARTICULATE MATTER TESTING GLASS FIBER MANUFACTURING HOLLINGSWORTH & VOSE FIBER COMPANY

RENDERED TO PRODUCT EVALUATED:

Michigan Department of Environmental Quality - Air Quality Division ADDITIONAL TECHNICAL INFORMATION FOR BOILERS

Tennessee Gas Pipeline Company, LLC Compressor Station Whites Creek Pike Page 1

STATE OF WYOMING AIR QUALITY DIVISION PORTABLE ANALYZER MONITORING PROTOCOL

RENDERED TO PRODUCT EVALUATED:

RENDERED TO PRODUCT EVALUATED:

RENDERED TO PRODUCT EVALUATED:

DETERMINATION OF CONCENTRATION AND MASS FLOW OF PARTICULATE MATTER IN FLUE GAS FOR STATIONARY SOURCE EMISSIONS

Atmospheric Emissions from Stationary Combustion Turbines

SHASTA COUNTY DEPARTMENT OF RESOURCE MANAGEMENT AIR QUALITY MANAGEMENT DISTRICT

GEOENERGY WET ESPS FOR BOILER MACT APPLICATIONS

ALABAMA DEPARTMENT OF ENVIRONMENTAL MANAGEMENT AIR DIVISION INSTRUCTIONS FOR COMPLETING ADEM FORM 110 APPLICATION FOR AIR POLLUTION CONTROL DEVICE

State of New Hampshire Department of Environmental Services Air Resources Division. Temporary Permit

Robert Remkes - Principal, Remkes Technology and Services

TEST REPORT SCOPE: EMISSIONS, EFFICIENCY AND OUTPUT FUEL: EPA TEST FUEL (CRIBS) TEST STANDARD: EPA MODEL: S245E WOOD STOVE

RELEASE POINT TYPE Enter or select one of the following stack/emission point release orientation: downward

EXAMPLE: TEST PLAN FOR SOLVENT BASED PRINTING & COATING PROCESS SOURCES

Proposed Guidelines for the Reduction of Nitrogen Oxide Emissions from Natural Gas fuelled Stationary Combustion Turbines

METHOD 1A - SAMPLE AND VELOCITY TRAVERSES FOR STATIONARY SOURCES WITH SMALL STACKS OR DUCTS. NOTE: This method does not include all of the

Stephenson CO-GENERATION PLANT STACK EMISSION TESTING TOOHEYS PTY LTD LIDCOMBE, NSW PROJECT NO.: 5938/S24635/18 DATE OF SURVEY: 12 MARCH 2018

VOLATILE ORGANIC COMPOUNDS

SWCAA Emission Inventory Instructions

Emissions Testing Report 2014

Emissions Testing Report 2015

Manitoba Environment

Determination of the Ethylene Oxide Control Efficiency from Catalytic Oxidizers. A Guidance Document

METHOD BERYLLIUM SCREENING METHOD. Analyte CAS No. Sensitivity Beryllium (Be) Dependent upon analytical procedure used

State of the Art (SOTA) Manual for Stationary Gas Turbines

Fluid Mechanics, Heat Transfer, Thermodynamics. Design Project. Production of Ammonia

SANTA BARBARA COUNTY APCD GUIDANCE DOCUMENT FOR EMISSION VERIFICATION OF CONTAMINATED SOIL/GROUNDWATER CLEANUP (CSC) PROCESSES

River Road Generating Plant. Title V Basis Statement

Stephenson CO-GENERATION PLANT STACK EMISSION TESTING TOOHEYS PTY LTD LIDCOMBE, NSW PROJECT NO.: 5648/S24184/16 DATE OF SURVEY: 24 MARCH 2016

AIR QUALITY PERMIT Issued under 401 KAR 52: Wolohan Drive, Suite 1 Ashland

~ SWCAA. Q~;r;!{~ Paul T. Mairose Chief Engineer. Southwest Clean Air Agency. December 22, 2017

Title V. Model General Permit Template SERIES 1 FLARES. Template # SJV-FL-1-1

PERMIT APPLICATION REVIEW SUMMARY

Stephenson CO-GENERATION PLANT STACK EMISSION TESTING TOOHEYS PTY LTD LIDCOMBE, NSW PROJECT NO.: 5522/S23794/15 DATE OF SURVEY: 15 JULY 2015

COMAR Amendments and Regulation.12 Standards for Biomass Fuel-Burning Equipment Equal to or Greater Than 350,000 Btu/hr

Technical Manual Guidelines for Compliance Stack Emission Test Programs

Technical Manual Guidelines for Compliance Stack Emission Test Programs

PRIMARY OR ALTERNATIVE OPERATING SCENARIO

Technology Advancement and Standards for Biomass Fuel to Energy Conversion. Topics Covered

SAN JOAQUIN VALLEY UNIFIED AIR POLLUTION CONTROL DISTRICT DRAFT STAFF REPORT

Document No.: NOKETL / IPPC Licence No.: W

SUNY Westchester Community College Air Emissions Permit Program Latest Revision Date January 2, 2016 Previous Revision Date June 12, 2015.

RULES OF TENNESSEE DEPARTMENT OF ENVIRONMENT AND CONSERVATION DIVISION OF AIR POLLUTION CONTROL CHAPTER VISIBLE EMISSION REGULATIONS

INTHUU MEASUREMENTS CC

AIR EMISSION PERMIT NO ADMINISTRATIVE AMENDMENT IS ISSUED TO. Northern States Power Company

e~~ny Co 4y~,. :. ~.. : ~ ~ ~.,. ~ ~ A AIR QUALITY PROGRAM th Street, Bldg. #7 Pittsburgh, PA

Technical Guidance Note (Monitoring) Medium Combustion Plant Directive and Generator Controls: monitoring point source emissions

RULES OF TENNESSEE DEPARTMENT OF ENVIRONMENT AND CONSERVATION DIVISION OF AIR POLLUTION CONTROL CHAPTER VISIBLE EMISSION REGULATIONS

Dan Deatsch Thompson Environmental Consulting

2. TECHNICAL DESCRIPTION OF THE PROJECT

EPA Method 1 Field Procedures Example:

Southwest Clean Air Agency Page 1 of NE 99 th Street, Suite 1294, Vancouver, WA Voice: (360) Fax: (360)

TruePeak TDLS200. NH 3 Slip Measurement. <Document Number> Copyright Yokogawa Electric Corporation <date/time>

METHOD 4 - DETERMINATION OF MOISTURE CONTENT IN STACK GASES. NOTE: This method does not include all the

\)0 l () Arkansas Department of pollution Control and Ecology Division of Air pollution Control. Summary Report Relative to Permit Application

NOTICE OF ADOPTION OF FINAL RULE. Department of Environmental Protection. Statement of Basis and Purpose

Test Report TR1R0

502(b)(10) Permit for Part 70 Source

PERMITTEE Seminole Electric Cooperative, Inc North Dale Mabry Highway Tampa, FL 33618

DRAFT AUTHORITY TO CONSTRUCT

Appendix A. An Introduction to Steam Turbine Selection

7 th NATIONAL CERTIFICATION EXAMINATION Nov FOR ENERGY MANAGERS & ENERGY AUDITORS

Portable Infrared Flue Gas Analyzer Gasboard 3800P

Stack Testing 101 Workshop

AIR EMISSION PERMIT NO IS ISSUED TO. LSP - Cottage Grove LP

STATEMENT OF BASIS Dudley Lumber Company, Inc. Salem, Lee County, Alabama Facility Permit No. 206-S003

PERMIT APPLICATION REVIEW SUMMARY

EPA vs. EN standards

BetaGuard PM Particulate Monitoring for Portland Cement MACT

Industrial Gas Analyzers in Applications Information

International Journal of Advance Engineering and Research Development

STATEMENT OF BASIS Mannington Mills, Inc. dba Mannington Wood Floors Epes, Sumter County, Alabama Facility/Permit No

Marquette General Health System December 11, 2001 Permit No B Page 1 of 8. Table of Contents

EPA s Methane Agenda Will the Oil & Gas NSPS OOOOa Regulation Affect Other Sectors? Presented By: Jay Christopher Trihydro Corporation

SAN JOAQUIN VALLEY UNIFIED AIR POLLUTION CONTROL DISTRICT COMPLIANCE DEPARTMENT COM 1150

Review of ConocoPhillips Alaska Inc. Continuous Emissions Monitoring Data from a 2014 Drill Rig Study at Kuparuk Drill Site 2N

USKON AKIŞKAN KONTROL SİSTEMLERİ SANAYİ VE TİCARET LTD. ŞTİ.

Title: Standard Operating Procedure for the Continuous Measurement of Ambient PM using a Beta Attenuation Monitor

Title V. Model General Permit Template SERIES 3 INTERAL COMBUSTION ENGINES. Template # SJV-IC-3-1

Engineering Summary UNH Cogeneration Project Fall 2003, Durham, NH

ABB Measurement & Analytics Monitoring cement plant stack emissions using FTIR

True Performance in Flow Measurement. Verabar. Velocity Averaging Flow Sensors

Drying of High-Moisture Coals For Power Production & Gasification

PERMIT APPLICATION REVIEW SUMMARY

AIR EMISSION PERMIT NO IS ISSUED TO. Van Hoven Company, Inc.

Transcription:

Source Test Guidance Test plans are required to be submitted to SWCAA prior to testing. Generally the plans must be submitted 2 weeks prior to testing but may be different based on individual facility permit conditions. Generally, source test reports are to be submitted to SWCAA not more than 45 calendar days from the end of testing. This is a permit condition and is enforceable. Tune up test reports are generally to be submitted to SWCAA no later than 15 calendar days after completion. If the source test is being performed on a piece of equipment that has combustion exhaust gases in the air stream, the fuel consumption rate should be monitored and recorded during the testing. These values should then be recorded in the test report data sheets and in the summary. To the extent practical, EPA Method 19 should not be utilized instead of EPA Methods 1-4 to determine firing rates or other process parameters unless specifically identified or allowed in the Air Discharge Permit or a pre-approved modified plan. Source Test Report Guidance The Source Test Report should: have a date performed and date report issued identified on the report; be signed by a responsible individual representing the test company; be provided in electronic PDF format as well as hardcopy; identify source test witnesses; report all values in English units not metric units; both English and metric units should be reported only if an EPA standard such as a MACT or NSPS standard has limits specified in metric units; be clear that NO x is monitored and reported as NO 2 unless otherwise indicated; identify VOC values as monitored and then as corrected to propane, hexane or as the main VOC component measured but not reported as methane because methane is not a VOC; propane is the preferred correction VOC lacking other specific instructions; an alternative is to report the VOC in units as measured of itself. The permit will generally specify the correction basis. If in question, contact SWCAA for guidance; include a copy of the SWCAA test protocol from the Air Discharge Permit in an appendix to the test report; identify the SWCAA Air Discharge Permit (not Title 5 Permit) for the facility that requires the testing in the summary: include a column on the summary page that identifies the permit limit for individual pollutants; include stack height (feet), diameter (inches), temperature (deg F), O 2 and CO 2 % values, and flowrates (both acfm and dscfm); include relevant process data such as firing rate (MMBtu/hr) or process/production rates to be able to correlate to maximum design values (number of parts produced or volume processed) to determine if testing was performed at maximum or near maximum conditions or as specified in the Air Discharge Permit. Firing rate should be calculated both by fuel consumption rate and Btu value and using EPA Method 19; data should be reported to 2 non-zero significant figures data should not be manipulated to account for accuracy of the test equipment these values should be included in supporting data in test report appendices; SW Clean Air Agency Emission Test Report Content and Format 1

I. Introduction Background information pertinent to the test should be presented in this section, including but not limited to: A. Reasons for conducting test (permit requirement, NSPS requirement, permit application, etc.). B. Concise statement of applicable regulations and permits, including permit numbers and issuance dates. C. Test date(s). D. Startup date, and maximum production rate achieved date for the source being tested. E. If the test is not done within 60 calendar days after achieving the maximum production rate at which the source will operate or within 180 calendar days after the initial startup of the source (if maximum production rate was not achieved), or not within the time period specified in the permit, then explain why not. F. Brief description of plant process and pollutant points being sampled. G. Company name, contact person, mailing address, telephone number. H. Facility name and physical location. I. Name of testing organization, contact person, mailing address, telephone number. J. Name of each person present at the test and each person's affiliation. K. Unit description(s) and permitted capacity(ies) (use derated horsepower for IC engines). Include unit make, model number, serial number, and location within plant. Identify each unit as it is identified in the permit and within the plant (plant names and numbers). L. Control equipment description. Include make, model number, and serial number. M. A photograph of the emission unit and/or stack configuration where the sampling was performed. II. Summary This section should summarize in tabular form the test results for each unit tested: A. For each run, show velocities (stack velocity in feet/second), flows (stack exhaust flow in actual cubic feet/minute and dry standard cubic feet/minute), concentrations, emission rates including the average of the emission rates from all runs, allowable emission limits, stack temperature and pressure as measured at the sampling probe, sampling times, pitot tube average results, etc. Include opacity reading if applicable. Also show the results of cyclonic flow determination. B. Unit operating parameters at time of test: For engines include: actual horsepower (at test time), engine speed (rpm), ignition timing, intake manifold pressure, fuel consumption rate (if available), A/F ratio controller setting. For turbines include: actual horsepower (at test time), turbine speed (rpm), fuel consumption rate, turbine exhaust temperature, ambient temperature, relative humidity. For steam injected turbines also include fuel to water ratio. If the engine or turbine drives a compressor or pump, include suction and discharge pressures and temperatures, inter-stage pressures and temperatures, suction volume and type of fluid pumped or compressed. If the engine or turbine drives a generator, include output voltage, current, and power. For heaters, boilers, or furnaces include: fuel consumption rate, feedstock rate, and firebox temperature and O 2 concentration. Unit operating level at time of test. If the unit was not operated at 90% of permitted capacity (derated horsepower for IC engines) provide an explanation. If testing a turbine using Method 20, include the four required operating loads unless otherwise specified in the permit or approved test protocol. C. Control Equipment Operating Parameters at Time of Test Include, as applicable, pressure drops, inlet and outlet temperatures, T/R readings for electrostatic precipitators, water flow rates for scrubbers, etc. III. Test Procedures - This section describes the test procedures, including any variations from EPA test methods. This section should include, but is not limited to: A. Schematic drawing of the process being tested showing emission points, sampling sites, and stack cross section. The sampling points should be labeled and dimensions indicated. B. Schematic drawing of the sampling device/train used. Each component should be labeled and explained in a legend. C. A brief description of the EPA reference methods used to operate the sampling train and the procedures used to recover and analyze the samples. Include sampling durations, number of test runs, calibration procedures, leak checks, cyclonic flow checks, etc. SW Clean Air Agency Emission Test Report Content and Format 2

D. Any deviation from EPA reference methods or from the original protocol and who at SWCAA approved the deviation. E. Make and model of test instrumentation and specifications including sensitivity, interferences, response time, linearity, span and range, calibration dates/method. F. A brief description of the methods used to obtain plant or unit operating parameters/ conditions. Measured parameters must be clearly distinguished from derived parameters. IV. Data and Calculations- This section should include copies of all raw data an at least one example calculation for every derived number showing all equations used. This section should include, but is not limited to: A. All raw data used in the emissions calculations: 1. Plant operating parameters. 2. Unit operating parameters. 3. Stack parameters (including cyclonic flow data). Include diagram showing test location on stack, dimension from test port locations to upstream and downstream disturbances, identification of test port location relative to final discharge to ambient air, photo preferred. 4. Control equipment operating parameters. 5. Isokinetic calculations, if applicable. B. Laboratory data, including blanks, tare weights, and results of analysis. C. Labeled copies of strip charts. D. An example calculation for every calculated result showing how the result was derived from the raw data. Show all equations used and any approximations. Carry out to completion the calculations for at least one test run. E. Analysis and certification documents for calibration gases. List expiration dates. (Warning: transferring the gas to a secondary container voids the certification. F. Audit sample results (if applicable). G. Visible emissions field sheets (Method 9) where applicable. H. Sample chain of custody, if applicable. Show names of custodians, method of transportation, departure and arrival times/locations. I. Quality Assurance documentation. V. Appendix Place any additional information in this section, including but not limited to: A. Any complications during the tests or with plant operations and how these might have biased the results. B. Any special information that might be helpful for performing future tests at this site. C. Brief resumes including experience of test personnel. D. Copies of pertinent pages from the facility/equipment air discharge permit. SW Clean Air Agency Emission Test Report Content and Format 3

Table 1 - Summary SUMMARY OF RESULTS METHODS 1, 2, 3, 4, 5/202, 7, 10, 25 and 9 (equipment name) (test company name) File name: Client: Location: Equipment LocationTested Units RUN #1 RUN #2 RUN #3 AVG Limit Lab No Date Start Time End Time Sample Length Minutes Sample Volume ft 3 Sample Volume Dscf Sample weight Mg Isokinetics % SOURCE PARAMETERS O 2 % CO 2 % Stack moisture (BWS) % Stack temperature deg F Stack diameter inches Stack area sq ft Stack height (approx) ft AGL Test location diameter inches Flow rate (Dry Standard) dscf/min Flow rate (Actual) acf/min Stack gas velocity ft/sec Fuel type Firing rate MMBtu/hr Process/Production rate (specify units) Control Equipment rate (specify units) SAMPLING RESULTS CO concentration - uncorrected CO rate / hr CO rate / production CO concentration - corrected @xx%o 2 VOC concentration uncorrected (C 3H 8) VOC rate / hr (C 3H 8) VOC rate / production (C 3H 8) VOC concentration corrected (C 3H 8) @xx% O 2 NOx concentration - uncorrected NOx rate / hr NOx rate / production NOx concentration - corrected @xx% O 2 PM concentration uncorrected (front) gr/dscf PM rate / hr (front) PM rate / production (front) PM concentration corrected (front) gr/dscf@xx% O 2 SW Clean Air Agency Emission Test Report Content and Format 4

Table 1 - Summary SUMMARY OF RESULTS METHODS 1, 2, 3, 4, 5/202, 7, 10, 25 and 9 (equipment name) (test company name) PM concentration uncorrected (back) gr/dscf PM rate / hr (back) PM rate / production (back) PM concentration corrected (back) gr/dscf@xx% O 2 PM concentration uncorrected (total) gr/dscf PM rate / hr (total) PM rate / production (total) PM concentration corrected (total) gr/dscf@xx% O 2 SO 2 concentration uncorrected SO 2 rate / hr SO 2 rate / production SO 2 concentration corrected @xx% O 2 Opacity % NH 3 concentration uncorrected NH 3 rate / hr NH 3 rate / production NH 3 concentration corrected @xx% O 2 (Other pollutants below) SW Clean Air Agency Emission Test Report Content and Format 5