Technical Bulletin. Open-Cell Spray Polyurethane Foam Equipment Set Up and Processing: (Please Review Technical Data Sheet)

Similar documents
STAYCELL APPLICATION GUIDE

SES FOAM 0.5 LB SPRAY INSTALLATION INSTRUCTIONS

Concrete Masonry Unit Block Fill Installation and Estimating Guide

Substrate/Ambient Temperature Standard 50 F to 120 F Polar 30 F to 80 F

Retrofit Installation Guide

Application Specification:

Application Specification:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: BASF CORPORATION EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: BASF CORPORATION

Master Specification ENERTITE by BASF Canada Inc. Section SPRAY POLYURETHANE FOAM INSULATION Page 1

ESR-2847 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

JM Corbond ocx SPF Open-Cell Spray Polyurethane Foam

ICYNENE INSTALLATION INSTRUCTIONS

ICC-ES Evaluation Report. ESR-3102 Reissued July 1, 2013 This report is subject to renewal August 1, 2015.

Bayseal Wall Insulation for Commercial Building Envelope Insulation Specification

Foamed-in-place insulation Sprayed insulation. Spray Foam Insulation for Residential Building Envelope Insulation

INSTALLATION GUIDE JM CORBOND III CLOSED-CELL SPRAY POLYURETHANE FOAM

Tech Tip: Cold Weather Roof Coating Recommendations

GUIDE SPECIFICATION BAYSEAL INSULATION FOR RESIDENTIAL ENVELOPE INSULATION

ICYNENE INSTALLATION INSTRUCTIONS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: THE DOW CHEMICAL COMPANY

INSTALLATION INSTRUCTIONS

ESR-2072 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: TERMAL INSULATION SECTION: AIR BARRIERS REPORT HOLDER:

TECH SOLUTIONS A Prescriptive Solution to Meet Air Barrier Energy Code Requirements in Metal Buildings

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

SECTION Blown Insulation THERMAL INSULATION

INSTALLATION GUIDE EPS FOAM

V-Pur S-84L V-PUR S-84L. Polyurethane Spray Foam System certified according to EN Description

JM Corbond oc SPF Open-Cell Spray Polyurethane Foam

WITSELL EVANS RASCO I ARCHITECTS/PLANNERS 901 West Third Street Little Rock, Arkansas ADDENDUM 3

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: SES FOAM

FUNDAMENTALS OF SPF FOR THE INDEPENDENT BUILDING ENVELOPE INSPECTOR CHAPTER 3 JOB SITE QUALITY CONTROL FOR THE BUILDING ENVELOPE

OPERATION, SAFETY & PROCEDURE GUIDELINE MANUAL FOR

Standard practice for installing cellulose building insulation

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: BASF CORPORATION (RIGID PU SYSTEMS)

JM Corbond III. Closed-cell Spray Polyurethane Foam IAPMO ES #0146

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CHEMICAL BROTHERS INTERNATIONAL, LLC

Compliance Standards of Coated SPF System: inclusive of Permax 108 or Permax 115 Acrylic Elastomeric Coating ± 100

ICC-ES Evaluation Report. ESR-1154 Reissued July 1, 2012 This report is subject to renewal September 1, 2014.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CHEMICAL BROTHERS INTERNATIONAL, LLC

TECH SOLUTIONS THERMAX Insulation in Low Humidity Metal Buildings

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: AIR BARRIERS REPORT HOLDER:

ESR-3136, ES 336 Technical Data Sheet

Working Smart with Low Pressure Spray Polyurethane Foam. Leba Lualdi, Fomo Products, Inc BPI Certified Building Analyst

Originally Issued: 08/03/2017 Revised: 02/01/2019 Valid Through: 08/31/2019

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION DIVISION: AIR BARRIERS REPORT HOLDER:

ARCHITECTURAL SPECIFICATIONS & INSTALLATION INSTRUCTIONS

Closed-cell Spray Polyurethane Foam Canadian Formula CCMC L

DIVISION: 07- THERMAL AND MOISTURE PROTECTION Section: Thermal Insulation REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: AIR BARRIERS REPORT HOLDER:

JM Corbond oc OPEN-CELL SPRAY POLYURETHANE FOAM CMCC # R

DIVISION: THERMAL AND MOISTURE SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

FUNDAMENTALS OF SPF FOR THE INDEPENDENT BUILDING ENVELOPE INSPECTOR CHAPTER 2 DESIGN, APPLICATION AND WORKMANSHIP FOR THE BUILDING ENVELOPE

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: RHINO LININGS CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: THERMOSEAL LLC EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS

JM Corbond III Closed-cell Spray Polyurethane Foam Canadian Formula CCMC L

JM Corbond III. closed-cell Spray Polyurethane Foam

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: NATURAL POLYMERS, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

Master Specification WALLTITE Eco v.3 by BASF Canada Inc. Section SPRAY POLYURETHANE FOAM INSULATION Page 1

PRODUCTION SPECIFICATIONS INSULATED CONCRETE FORMS

PRODUCTION SPECIFICATIONS INSULATED CONCRETE FORMS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: BAYER MATERIALSCIENCE, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: AIR BARRIERS REPORT HOLDER: DAP FOAM, INC.

Foam Vs Fiber. Air Sealing Benefit of Foam in Single Family Residential New Construction. Gary Parsons Fellow, Dow Building Solutions R&D

Master Specification WALLTITE ECO v.2 by BASF Canada Inc. Section SPRAY POLYURETHANE FOAM INSULATION Page 1

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC.

3.0 DESCRIPTION. Division: Thermal and Moisture Protection Section: Thermal Insulation

ESR-2600 Reissued February 1, 2011 This report is subject to re-examination in two years.

Technical Product Data

HouseWrap Applications System R-Value: R-4.17 Horizontal Heat Flow Only

Technical Product Data

Technical Product Data

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

Originally Issued: 11/06/2017 Valid Through: 11/30/2018

International Fireproof Technology Inc.

Insulating Attics & Crawlspaces. Roger Morrison, PE, RRC NCFI Polyurethanes

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS

Thermasheath-XP. Insulation for Exposed Use

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: THE SPRAY MARKET, INC.

Trusted DIVISION: 07 SYSTEM. Conformity! ICC-ES Evaluation. not specifically. Copyright 2014

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

A Closer Look Inspection Service 2015 IECC Residential DFW area handout

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: SPRAY FOAM POLYMERS

Elastocoat Protective Coatings APPLICATION GUIDE

Spray Foam - Frequently Asked Questions

GAF EnergyGuard Polyiso Wall Sheathing

A Guideline for Securing Roofing Components with SPF Adhesives

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: BASF CORPORATION

MDI polymeric (Methane diphenyl diisocyanate)

Seal the deal in a way no one else can.

Best Practices in Foam Plastic Installations By: Henri Fennell, CSI/CDT. Copyright Materials

Originally Issued: 04/17/2015 Valid Through: 04/30/2016

SECTION THERMAL INSULATION

P.O. Box 1528 Mount Airy, NC InsulStar

Transcription:

Open-Cell Spray Polyurethane Foam Equipment Set Up and Processing: (Please Review Technical Data Sheet) ENERTITE NM may be installed in new or retrofit constructions. In either case, the product must be installed in open cavities in the following locations in a wood-frame and metal stud construction that meets the requirements of the design professional, local codes and proper building science principles: Exterior walls including perimeter joists Cathedral ceilings Floors separating living spaces from a garage Cantilever overhang floors Interior below-grade foundation walls (proper moisture management must be employed). Partition walls and floors where improved sound containment is desired. Read and understand all safety and operation requirements for spray foam and other equipment to be used for the application ENERTITE NM applications are to only be done by professional and trained applicators that have an understanding of the spray foam equipment and insulation applications. This is not a do-ityourself product. The spray application site needs to be inspected before the spraying starts. Safety Read and understand the Technical Data Sheet (TDS) for ENERTITE NM product A and B compounds Read and understand the Material Safety Data Sheet (MSDS) Obtain all necessary personal protection equipment (PPE), the required training and medical screening before proceeding with the application Read and follow Industry Guidelines found at www.spraypolyurethane.com Two-component foam proper set up Isocyanate (A); Resin (B) Technical Bulletin

General Information IMPORTANT INFORMATION Operating equipment temperature settings for A+B primary heaters are 120 F to 140 F. Operating equipment pressures for A+B should be between 800-1100 psi. Shelf life of Resin (B) component is one year. Two-part equipment designed to properly process SPF compounds are required. The application equipment, such as Graco equipment, must be designed to safely install and mix the liquids to form spray polyurethane foam. DO NOT mix this material nor does it require recirculation. The resin temperature in drums must be 70-85 F or higher before spraying can begin. Optimum operating temp 120 F to 145 F for the A and B primary heaters and heated hose with an operating variance range of +/- 5 F for all settings as adjustments are needed. Pressures for A/B: should be an 800 psi minimum to 1100 maximum psi range while spraying. Foam should not be sprayed at ambient temperatures or to targets that are below 40 F in temperature reading. Temperatures at or below 60 F or any substrate target that is a heat sink requires a flash pass (½ thick) to optimize the second lift of open-cell material. Most SPF materials and applications perform better under warmer target conditions. Proper planning of the spray application must be done prior to starting the job. Considerations for overspray protection, site control of non PPE protected people, anticipated application and other general construction considerations must be considered well in advance to the start of the spraying job. Do not spray additional SPF onto rising SPF in order to avoid possible excessive heat build up within the foam material. Application ENERTITE NM must be applied by qualified applicators. Properly processed ENERTITE compounds will produce high quality polyurethane foam reprehensive of the TDS, when applied in accordance with BASF s instructions and industry practices. The normal application temperature range for ENERTITE NM is 40 F and warming to 120 F. If it is sprayed at lower temperatures, there is a risk that the adhesion between the foam and substrate may be affected and the physical properties may not reflect what is represented on our ENERTITE NM TDS. Before and during spraying, the resin should be agitated with a corkscrew-style or similar acceptable mixer. Processing Parameter The processing parameter would include a machine capable of 1:1 ratio by volume output, chemical dispensing pressures of 800-1500 psi and a heating system to maintain the desired liquid compound temperatures while spraying. A dedicated machine is suggested when processing ENERTITE NM to prevent contamination when switching over from closed-cell spray foams. If the same unit will be used, care must be taken to properly clean out the resin side when switching from closed-cell to ENERTITE NM open-cell foam. The heavier and thicker closed-cell resin may cling to and affect the ENERTITE NM foam product for several minutes of spraying after switching over. Consult your BASF contractor sales person or our BASF Technical Department (800-706-0712) with further questions. Process Requirements Graco spray foam guns capable of 2.3 6.8 kg/min (5 20 lb/min) output Dry air is required to be used to supply SPF guns. Primary heaters set between 115 145 F and ability to maintain 115 145 F while processing Automatic hose heat control and properly insulated hoses need to be in proper working order. Drums to be at 15-25 C or 70-85 F for best application performance Liquid A and B materials are to be stored in a clean, dry area between the temperature ranges of 50-80 F. 2 Open Cell Foam Equipment Setup and

Application Techniques Ensure that the substrate is clean and dry before spraying. Apply only indoors. Allow 10-15 minutes before cutting. Can be applied up to 6 per pass or lift. Allow minimum of 5 minutes in between each lift. During application, steam will be produced from ENERTITE NM as a product of the chemical reaction. Warning: the foam will be HOT for a period of time. Preferred spraying is from side to side of the cavity, but it can be sprayed vertically. Keep passes to less than 2' wide to help reduce voids within the ENERTITE foam mass. Keep the gun between 12 to 18 from substrate. Overlap a minimum of 50-75% between passes, adjusting arm speed and gun to target distance accordingly. Fill stud with liquid completely; do not leave any. unsprayed areas allowing the foam to fill them. Spray every other stud or rafter cavity to facilite trimming and then go back and fill in the others after the first ones have been trimmed. Fill stud with liquid completely; do not leave any unsprayed areas allowing the foam to fill them. Spray every other stud or rafter cavity to facilite trimming and then go back and fill in the others after the first ones have been trimmed. Special Notes ENERTITE is NOT designed for use as an EXTERIOR roofing system. Enertite is not intended for cold storage structures such as coolers and freezers. High humidity rooms, such as pools, demand special design considerations with regards to thermal insulation and moisture- vapor drive. Typically, there should be no compatibility issues changing from one open-cell product to the ENERTITE NM open-cell product. However, the operator should run a quality control check to confirm this once the new material has completely filled the equipment and before applying the material in the wall cavity. Going from Enertite NM to any BASF s closed cell material or vice versa does not require any special steps. One material can be pushed through the lines with the other. The material can be either bled out or sprayed out. When spraying out closed-cell material, there will be some cross contamination of the two resins. The result will be the rise of open-cell foam but the skin and cells of closed-cell foam. Continue to spray until the cells are opened. NOTE: closed-cell resin that has set in a line for some time will take longer to flush out. When spraying out open-cell material, there will be some cross contamination of the resins. Continue spraying out until the difference in the foam is noticed. Be careful of this; improperly mixed and perhaps off ratio foam can result in possible exothermic build up. This could lead to an excessive heat build up in the foam mass and result in an ignition. We suggest you always store these away from each other, located outside and away from combustible materials. Cut open the foam mass into small masses and allow air to ventilate. Any large volume of flush matter ( > 12" thick ) should be cut and stored away from combustible materials. The finished ENERTITE NM spray foam insulation is combustible and will burn with open flame, oxygen. Special care must be taken to avoid open flames, welding torches, and other hot work near the unprotected foam surface. June, 2010 3

Protecting Yourself With proper precautions and the use of personal protective equipment (PPE), professional applicators and workers can protect themselves from overexposure to MDI/PMDI and other spray foam ingredients during the application of the SPF system. People that do not have the necessary training and personal protection equipment cannot be around the spray area. Interior Spraying When spraying a spray polyurethane foam system indoors, sprayers and helpers should wear: A NIOSH-approved full face or hood-type supplied air respirator (SAR) (as outlined in your company's Respiratory Protection Program). MDI-resistant chemical gloves (e.g., nitrile), or fabric gloves coated in nitrile, neoprene, butyl, or PVC Chemically resistant long-sleeve coveralls or chemically resistant full body suit with hood MDI-resistant fitted boots/booties Professional applicator wearing proper PPE for application of SPF system. 4 Open Cell Foam Equipment Setup and

AM BASF Corporation 1703 Crosspoint Avenue Houston, TX 77054 Fax: 713-383-4592 June, 2010 5