Store at 20 C prior to use. Allow package to equilibrate at room temperature before opening.

Technical Instructions for Spotting Microarrays

Typical probes. Slides per pack Aminosilane. Long oligo- Slide AStar None D surface. nucleotides

Multi-well formats. Overview method. Typical applications. 16-well slide. Surveillance chips 96-well SBS microplate

Epoxy Microarray Slides

Protocol. Epoxy Slide For Protein Array Applications. Version 2.1. February 2014

1. General. Contents. 2. Technical support. 3. Coated substrates. Aldehydesilane coating. Aminosilane coating. Epoxysilane coating

Instruction Manual for DNA-Microarrays

PATH Protein Microarray Slide (Product Numbers and ) Sandwich Immunoassay Protocol

Future in your hands.

πcode TM MicroDisc, Pre-activated (10-plex Sampler Kit) User Manual

Aldehyde Arraying Slides High quality slides designed for array production

Protein Array Assay System_Userguide

Reviewed: Hamilton. Contents; Overview. 2.0 Methods 3.0 Notes 4.0 Acknowledgements & References

Human BMP-2 ELISA Pair Set

Human Anti-Muscarinic Cholinergic Receptor 1 (M1)-Antibodies

Bacterial Reagent Set Indirect ELISA, Alkaline phosphatase label

Human IGFBP7 ELISA Pair Set

Antibody Array User s Guide

****** Competition ELISA Kit Instruction

Random Kinase Peptide Microarrays Off-the-shelf peptide microarrays

Anti-beta 1 Adrenergic Receptor Antibodies (IgG) ELISA

PEPperCHIP Immunoassay Protocol

Future in your hands.

Microarray Industry Products

SmartArrayer Series Microarray Spotters A High-throughput, Multifunctional Platform

Cell Proliferation Assay Kit, BrdU

Human TNF-alpha / TNFA / TNFSF2 ELISA Pair Set

Multiwell Peptide Microarrays

Human SLAMF6 / Ly108 ELISA Pair Set

Guinea pig 25-OH-VD ELISA Kit

PRODUCT DATA SHEET. Carboxylated Gold Nanoparticles. Description. Features. Storage. Applications. Handling. Characteristics

Human ECM1 ELISA Pair Set

Goat IgG ELISA Catalog #:

Human Junctional Adhesion Molecule A / JAM-A ELISA Pair Set

Human CD21 ELISA Pair Set

Human Transferrin / TF ELISA Pair Set

IR-Blot Secondary antibodies Rev01

Human C-Reactive Protein / CRP ELISA Pair Set

Human ADAM15 ELISA Pair Set

Mouse IFNAR1 ELISA Pair Set

IR-Blot Secondary antibodies Rev00

GAPS II Coated Slides

Cynomolgus p53 / TP53 ELISA Pair Set

Human AFP / alpha-fetoprotein ELISA Pair Set

Human CEACAM6 ELISA Pair Set

Microscopy Tools I: HybriWell Hybridization Sealing Systems, SecureSeal Hybridization Chambers, and HybriSlip Hybridization Covers

Procine CRP ELISA Kit

AMPURE PCR PURIFICATION PAGE 1 OF 7

Guinea pig PGI2 ELISA Kit

Canine PHA ELISA Kit

Human LENK ELISA Kit

Mouse RF IgM ELISA Kit

Chicken VEGF ELISA Kit

Rat GLO ELISA Kit. For the quantitative in vitro determination of Rat Glyoxalase concentrations in

Bovine IgG-Ab ELISA Kit

Guinea pig TIMP-1 ELISA Kit

Human CoxV-A16 ELISA Kit

Guinea pig Hyp ELISA Kit

mrna IN SITU HYBRIDIZATION For Sectioned Zebrafish

Human CTRP5 ELISA Kit

Porcine IgG ELISA. Package Insert

Human PTH / PTH1 / Parathyroid Hormone ELISA Pair Set

Mouse CD34 ELISA Pair Set

Monkey hs-tnt ELISA Kit

AGENCOURT CLEANSEQ Dye-Terminator Removal (ET Terminators)

Human Granulin / GRN / Progranulin ELISA Pair Set

Hydroxyproline ELISA Kit

Atrazine ELISA Kit. Catalog Number KA assays Version: 15. Intended for research use only.

ACE2 (Human) ELISA Kit

Cells and Tissue DNA Isolation 96-Well Kit (Magnetic Bead System) Product # 62500

Rat ACE2 / Angiotensin- Converting Enzyme 2 ELISA Pair Set

Blood DNA Isolation 96-Well Kit (Magnetic Bead System) Product # 62600

Human Fibrinogen ELISA Quantitation Kit. Manual

mouse IL-6 Catalog Number: DY406

Simplifying FISH. The SciGene MicroFISH System for Cytogenomics

RepliTope TM Antigen Collection Microarrays Ready-to-use peptide microarrays for antibody profiling

Reagents Description Storage

Mouse ICAM-1 / CD54 ELISA Pair Set

Rat Free Thyroxine (FT4) ELISA Kit

Glyphosate ELISA Kit. Catalog Number KA assays Version: 07. Intended for research use only.

SEEDEZ PROTOCOLS EXTRACTION AND QUANTIFICATION OF TOTAL PROTEIN ISOLATED FROM 3D CELL CULTURES IN THE SEEDEZ.

Rhesus CD16 / FCGR3 ELISA Pair Set

LabCyte CORNEA-MODEL

U-PLEX Biomarker Group 2 (Human, Mouse, and NHP)

Human filariasis (philariasis) antibody (IgG4) ELISA Kit

Buffers: (We recommend filtering the PBS buffer using a 0.45 µm filter before adding any supplements.)

Mouse Axl ELISA Pair Set

Human IgG ELISA Quantitation Set

Human Serum Albumin (HSA) ELISA Quantitation Kit. Manual

Odyssey Western Blotting Kits LT

Transcription:

Seite: 1/8 1 Introduction... 2 2 Storage and handling... 3 3 General precautions... 3 4 Reagents required... 3 5 Equipment required... 3 6 Array printing... 4 7 Printing guidelines... 4 8 Protein immobilization... 5 9 Blocking... 5 10 Assay conditions... 5 11 Target incubation... 5 12 Important information about patents... 8 For Technical Assistance, please contact Microarray Solutions SCHOTT North America Inc. 5530 Shepherdsville Road Louisville, KY 40228 USA Phone: +1-502-657-4430 Fax: +1-502-966-4976 E-Mail: coatedsubstrate@us.schott.com Additional information at: www.us.schott.com/nexterion

Seite: 2/8 1 Introduction Technical Instructions for Spotting Protein Microarrays PRODUCT OVERVIEW is developed for fast and efficient immobilization of proteins onto activated glass slides that permit superior reproducibility of microarray data and higher sensitivity. The slide is manufactured using the highest quality glass (standard dimensions of 75.6 mm x 25.0 mm x 1.0 mm) and laser cutting technologies, to obtain defect and particle free slide surfaces and excellent dimensional tolerances. is cleaned and coated in cleanroom atmosphere and a strict process control in all fabrication steps ensures excellent coating uniformity and batch-to-batch reproducibility. The epoxy surface coating reacts with all nucleophilic groups provided by amino acid side chains (NH 2 -, SH-, OH-) immediately and irreversible to form covalent bonds. The density of epoxy groups is uniform over the entire surface of slides and is adjusted to yield optimal binding. The uniform and ultrahydrophobic patterning material separates the slide surface into 16 individually addressable subarray chambers allowing multiplexed microarray analysis. is delivered together with superstructures and sealing strips to support excellent sample mixing and to minimize cross contamination as well as sample evaporation during the hybridization step. Additionally re-usable microtiterplate-size-trays for automated high-throughput processing of are available separately. Each MPX-4 tray can hold up to four slides. 6.59 2.42 2.96 4.71 6.59 2.42 25,0 mm 9.00 75,6 mm

Seite: 3/8 2 Storage and handling 1. The slides should be stored desiccated at room temperature and protected from the light and should be used prior to expiration date. 2. Open and use the slides in a clean environment to avoid particle build-up on the printing surface. 3. Avoid direct contact with the printing surface to minimize contamination and abrasion of the coated surface. 4. Sealed slides are stable for 6 months at room temperature. Once the package is opened, slides should be used within 8 weeks if stored under inert condition inside a desiccator protected from light at room temperature. 5. Only one side of each slide is patterned and must therefore be used (readable SCHOTT Nexterion ). This inscription can also be used for the well orientation. 3 General precautions 1. The protocols contained in this document are meant to be general guidelines only and some optimization may be required depending on the application and sample being used. 2. Refer to manufacturer supplied Material Safety and Data Sheets (MSDS) for proper handling and disposal of all chemicals. 3. is for research use only, not for in vitro diagnostic use. 4 Reagents required 1. Protein Print Buffer: PBS (137 mm NaCl, 9 mm KOH, 11.3 mm NaH 2 PO 4 ) 7.0-8.0 (a higher ph improve the immobilization but may interfere with protein stability) 2. Blocking Buffer: 1 % BSA in PBST (Alternatively, 3 % nonfat milk in PBST can be used) 3. Wash Buffer: PBST (PBS with 0.05 % v/v Tween 20 ph 7.4) 4. Rinse Solution: PBST 5 Equipment required 1. Humidified hybridization chamber (like GeneMachines HybChamber) or place a 1- inch layer of NaCl in a chamber filled with water and cover with an airtight lid. This forms a chamber with a nominally 75 % relative humidity. 2. Centrifuge with slide holders or compressed nitrogen gas for drying slides 3. Coplin jars (VWR 25457-006) or slide dish and rack combo (Fisher 900200) for washing slides

Seite: 4/8 6 Array printing Print proteins at a final concentration of 0.05-0.2 mg/ml in the print buffer at 50 % relative humidity using the following configurator table (Table 1) as a guideline into the wells of. 7 Printing guidelines is compatible with all microarray printing or spotting methods, including contact and non-contact printing technologies. The following table displays the maximum number of probes per subarray well for Nexterion Slide E MPX 16 based on theoretical calculations using pitch and type of source plate. The color-coding in the table indicates, for each pin configuration, the number of pins used for intra-well printing. Detailed printing guidelines are available online at: www.us.schott.com/nexterion Pitch (microns) 96 Well Sourceplate 384 Well Sourceplate Pin Configurations (1 x 1-2-4), (2 x 1-2-4) (1 x 1) (1 x 2-4-8) (2 x 1) (2 x 2-4-8) (4 x 1) (4 x 2-4-8) 100 3364 3364 1508 1508 676 1508 676 150 1444 1444 608 608 256 608 256 200 784 784 336 336 144 336 144 250 484 484 220 220 100 220 100 300 324 324 108 108 36 108 36 350 256 256 96 96 36 96 36 400 169 169 52 52 16 52 16 450 144 144 48 48 16 48 16 500 100 100 20 20 4 20 4 1 Pin / MPX well 2 Pins / MPX well 14 Pins / / MPX well 2 Pins / MPX well 4 Pins / MPX well Maximum Probe Densities for Nexterion Slide MPX 16 Security spacing is 300µm + pitch from well borders.

Seite: 5/8 8 Protein immobilization Place the printed arrays in a humidity chamber at room temperature for 1 hour. 9 Blocking Block slides for one hour in blocking solution at room temperature with slow shaking. 10 Assay conditions For protein incubation steps on the printed slide, we have found that PBST works well as a dilution buffer for the target solutions. The blocking buffer can also be used if an increase in nonspecific binding is observed. 11 Target incubation 1. Remove the protective back covering from the superstructure by hand or by using a forceps. 2. Apply the superstructure on a) from top or b) by inverting the slide on the superstructure, followed by c) firmly securing the superstructure on.

Seite: 6/8 a) Application from top b) Application in inverted position c) Securing the superstructure 3. Dilute the labeled target sample in a minimum of 40 µl of incubation or blocking buffer and pipette into the wells of a) individual slide or b) 4 slides placed in a molded tray. a) Addition of target to a single slide b) Addition of target to multiple slides in a tray

Seite: 7/8 4. Seal the wells immediately with the supplied sealing strips, as shown below, ensuring that the seal makes good contact with the superstructure. 5. Incubate with target solution for 1 h at room temperature. 6. Aspirate the target from the wells using a multi-channel pipette and immediately fill the wells with 100 µl of PBST. After 3 min incubation, aspirate the wash solution and fill the wells with fresh PBST. Repeat this procedure 3 times. 7. Remove the superstructure immediately and place the slides into a slide rack. a) Aspiration using a multi-channel b) Removal of superstructure 8. Wash in PBS for 10 minutes with agitation. 9. Dry the array in an oil free air or nitrogen stream to avoid water stains on the slide surface. 10. Protect the array from light, dust, and abrasion of the array surface, until ready for scanning.

Seite: 8/8 12 Important information about patents Using arrays based on SCHOTT Nexterion products for dual color analysis on a single array in which at least two different samples are labeled with at least two different labels may require a license under one of the following patents: U.S. patent nos. 5,770,358 or 5,800,992 or 6,225,625 and U.S. patent no. 5,830,645. Manufacturing and use of probe arrays may require a license under the following patents: U.S. patent no. 6,040,138 or 5,445,934 or 5,744,305 and under the following patents owned by Oxford Gene Technology Ltd. ( OGT ): European patent no. EP 0,373,203, U.S. patent nos. 5,700,637 and 6,054,270 and Japanese patent nos. 3393528 and 3386391 ("The OGT patents"). Other patents may apply. The purchase of SCHOTT Nexterion products does not convey any license under any of the OGT patents or any of the other patents referred to. For all applications SCHOTT North America Inc. and SCHOTT Technical Glass Solutions GmbH make no representation or warranty that the practice of its technology and products or any improvement will not infringe or violate any domestic or foreign patent of any third party. Before making or using any oligonucleotide arrays you should contact OGT to discuss a licence. To inquire about licensing under the OGT patents, please contact OGT at licensing@ogt.co.uk.