There are countless ways to improve constructability on your next project. Here are 50 of them. the need for it or specify it on the design drawings.

Similar documents
50 Tips for Designing Steel Framed Buildings September 27, AISC Live Webinar. AISC Live Webinars

Tips for Successful Delegation of Connection Design

Tech Tips SidePlate Connections FAQ 09/30/2017

2016 AISC Standards. Specification for Structural Steel Buildings & Code of Standard Practice for Steel Buildings and Bridges.

STEEL REACTION FRAME

Southwest Housing, Arizona State University

AISC Live Webinars. Thank you for joining our live webinar today. We will begin shortly. Please standby.

Danielle Shetler - Structural option Courtyard by Marriott Lancaster, PA

Contents. Tables. Notation xii Latin upper case letters Latin lower case letters Greek upper case letters Greek lower case letters. Foreword.

manualwise BRACED FOR BETTER SEISMIC DESIGN

Structural System. Design Criteria Fire Resistance Concrete designed for 2 HR rating (worst case) Geotechnical Report Allowable Bearing Capacity

BUILDING RETROFITS: BREATHING NEW LIFE INTO EXISTING BUILDING STRUCTURES

Figure 1 Example of HSS column splice

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

TECHNICAL REPORT 1. Structural Concepts / Structural Existing Conditions. Penn State Hershey Medical Center Children s Hospital. Hershey, Pennsylvania

PROJECT: TULSA COMMUNITY COLLEGE BOOKSTORE RENOVATION PROJECT NUMBER: ISSUE: CONSULTANT: SEAL: SHEET NUMBER: GENERAL NOTES

Supplemental Structural Correction Sheet Steel Moment Frame Design (2017 LABC)

CURVED STEEL I GIRDER BRIDGES RAMP GH OVER THE ERIE CANAL INTRODUCTION BEHAVIOR OF CURVED BRIDGES DIFFERENCES FROM STRAIGHT BRIDGES

CHAPTER 14 SLOTTEDWEB (SW) MOMENT CONNECTION

DIN EN : (E)

Tips For Designing Constructable Concrete Buildings

Principles of STRUCTURAL DESIGN. Wood, Steel, and Concrete SECOND EDITION RAM S. GUPTA. CRC Press. Taylor& Francis Group

Brent Ellmann Structural Option 200 Minuteman Park, Andover, MA Structural Consultant: Dr. Hanagan

Statement of Special Inspection Requirements

Whose responsibility is it? Design Responsibility. Steel Joist Institute. Standard Assumptions. Common Pitfalls in Steel Joist Specification

Kaleida Health Global Heart and Vascular Institute University at Buffalo CTRC/Incubator. Buffalo, New York. Technical Report #2

Crossroads at Westfields Building II

Building Design - The Intelligent Approach

steelwise WHAT S NEW WITH PREQUALIFIED CONNECTIONS? A look at the latest version of AISC 358.

SECTION PLATE CONNECTED WOOD TRUSSES

steelwise ARE YOU PROPERLY SPECIFYING MATERIALS? As material specifications change and improve, so too can your steel-framed buildings.

CORPORATE HEADQUARTERS

Steel Expansion. Located along the Grand River in

Investigation of Structural Steel Webs for Punching Shear

Interior Hangers. Application

GENERAL TOPICS & MEMBER DESIGN

AISC Live Webinars. Thank you for joining our live webinar today. We will begin shortly. Please standby.

HYBRID CONCRETE MASONRY CONSTRUCTION DETAILS. TEK 3-3B Construction (2009) Related TEK: 14-9A

Potential Solutions- Background: Current Designs. Potential Solutions. Goals for Design What are we concerned about?

fifteen design for lateral loads Lateral Load Resistance Load Direction Lateral Load Resistance

OCTAGONAL SHAPE REDUCES AIRPLANE HANGAR COSTS

ISSUE A Code Change # 2 Class 3 and Class 4 Buildings

Office Building-G. Thesis Proposal. Carl Hubben. Structural Option. Advisor: Dr. Ali Memari

CIRCULAR TUBE COLUMNS IN HIGH STRENGTH STEEL Economical solutions for building frames

fifteen design for lateral loads Lateral Load Resistance Load Direction Lateral Load Resistance

The New Columbia Joist Company ENGINEERING AND MANUFACTURING

TG Structural Steel Superstructure

STATE UNIVERSITY CONSTRUCTION FUND. UNIVERSITY CON DIRECTIVE 5-1 Issue date: October 2014

fifteen design for lateral loads Lateral Load Resistance Load Direction Lateral Load Resistance

1. Base plates, setting plates and anchor rods for columns. 8. Lintels if connected to structural steel columns.

Ductility of Welded Steel Column to Cap Beam Connections Phase 2

CORPORATE HEADQUARTERS

Temecula Medical Center Temecula, CA

SJI Updates Expanded Load Tables for Noncomposite Joists / Joist Girders and Development of New Composite Joist Series

OVERALL STRUCTURAL SYSTEM

Part 2: Evaluation and Modification of Open Web Steel Joists and Joist Girders

STEEL STRUCTURAL SYSTEMS

MOUNTAIN STATE BLUE CROSS BLUE SHIELD HEADQUARTERS

Structural Redesign Gravity System

Pro-Con Structural Study for Alternative Floor Systems October 27, 2004

David A. Walenga Technical Assignment #1

SJI Code of Standard Practice

THE FORENSIC MEDICAL CENTER

AIA St. Louis January 4 th, 2017 Phillip Shinn, PE Jacobs Engineering Washington University in St. Louis, Sam Fox School of Design and Visual Arts

Innovations in Tied Arch Bridges

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 3, No 2, 2012

Belmont Executive Center; Building A

1000 CONTINENTAL SQUARE

Survey and Testing of Pre-1988 Braced Frame Structures From The West Coast of the United States

SEISMIC BEHAVIOR AND DESIGN OF STEEL SHEAR CONNECTIONS WITH FLOOR SLABS

Types Of Roofs - Vault

Executive Summary. Non-Composite Steel system 2- Way Flat Concrete Slab Wood Beam with Form Deck Pre-Cast Hollow Core Plank

Supplement No. 1 to AISC Prequalified Connections for Special and Intermediate Steel Moment Frames for Seismic Applications

Kevin Wigton Structural Option. Technical Report III. Simmons College School of Management, Boston, Ma

Technical Report #2. Matthew R Peyton

STEEL DECKS FOR RAIL BRIDGES

Structural Tech Report #2 Pro Con Structural Study of Alternate Floor Systems

151 First Side. Technical Assignment 2 November 16 th, William J. Buchko. AE 481w Senior Thesis The Pennsylvania State University

1/26/2015 DETAILS CIP DETAIL EXAMPLES WHY SIMPLIFY DETAILS? CIP DETAIL EXAMPLES DETAILING FOR SIMPLICITY

THE PLAZA AT PPL CENTER HAMILTON BOULEVARD AT 9 TH STREET - ALLENTOWN, PA

VOLUNTARY - EARTHQUAKE HAZARD REDUCTION IN EXISTING HILLSIDE BUILDINGS (Division 94 Added by Ord. No. 171,258, Eff. 8/30/96.)

Steel Frame Structure

Overview of Presentation. SCBFs are Conceptually Truss Structures

conference preview A look at the AISC Chapter C stability provisions and the role of the K-factor in stability design.

ERRATA for G12.1, Guidelines to Design for Constructability, 2016 Edition

AISC Steel & Timber Research for High-Rise Residential Buildings

Sabah Shawkat Cabinet of Structural Engineering 2017

Composite Beam Design Manual AISC

Structural Design Engineers 120 Montgomery Street, Suite 1410 San Francisco, California / Fax 415/

Technical Report 1. Seneca Allegany Casino Hotel Addition. Salamanca, NY

How Beams Work, I. Statics and Strength of Materials

Spring Hill Suites Marriott

AISC DESIGN GUIDE 11 PDF

On Cold-Formed Steel Construction. Light Gauge Steel Engineers Association Washington, D.C Toll Free (866)

xiii Preface to the Fifth Edition Preface to the Second Edition Factors for Conversion to SI Units of

THE BRACE CONNECTION THE BOLTED OPTION FIGURE 1 MODEL SHOWING THE BOILER AND THE STRUCTURAL SUPPORT SYSTEM (BOILER BUILDING)

Open-Web Trusses. Including Red-L, Red-W, Red-S, Red-M and Red-H Trusses. Design Flexibility. Outstanding Strength-to-Weight Performance

CANTILEVER RACK SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE

Nabil A. Rahman, Ph.D., P.E.

Pro-Con Structural Study of Alternate Floor Systems

Transcription:

There are countless ways to improve constructability on your next project. Here are 50 of them. Tips to Take your Team to the Top By Matthew D. Brady, P.E., and Cliff Schwinger, P.E. We hear the word constructability all the time but what does it mean? Simply put, constructability is the ease with which a structure can be built. Constructable designs are more economical structures because they provide options and flexibility before work has progressed and the die is cast. The concept of constructability includes four main principles: Simplicity = Economy Least weight does not always = Least cost Fewer pieces = Greater economy Efficient design = Reduced cost Since the best, most constructable solutions for a project often depend on local construction practices and contractor preferences, the recommendations of the construction team including the fabricator and erector can improve efficiency and economy and add value to your project early on and along the way. Below are 50 tips, seperated by category, that can enhance the construcability of your next project. (Note: These tips are from the seminar 50 Tips for Designing Constructable and Economical Steel Buildings, presented at the 2011 and 2013 NASCC: The Steel Conference.) Connections Tip 1: Design s per the requirements of the building code and AISC 360 (and AISC 341 if it is applicable). Tip 2: If delegating design work to an engineer working for the fabricator, do so properly with Option 3 in Section 3.1.2 in AISC 303-10, the AISC Code of Standard Practice. Tip 3: And also, show the reactions, moments and axial forces from Tip 1 when using Tip 2. Tip 4: Provide load combinations and directions of reactions, moments and forces (Figure 1) at joints so the engineer doing design can satisfy statics (always a plus!). Tip 5: Provide sufficient information on the drawings to minimize uncertainty among bidders. Section 3 in the AISC Code of Standard Practice lists the typical information needed to get responsive and comparable bids. Tip 6: Understand that fabricator preferences differ regarding preferred details; some like shear tabs, others like all-bolted single or double angles, etc. Tip 7: Don t delegate design of reinforcing around beam web openings. Either eliminate the need for it or specify it on the design drawings. See AISC Design Guide 2: Steel and Composite Beams with Web Openings for more guidance (Figure 2). Tip 8: Don t delegate design of plate girder welds (Figure 3). Tip 9: Think about how the s will be configured and detailed, even when using Option 3 in the AISC Code of Standard Practice. Figure 2 Figure 3 Fabricator to reinforce webs at openings where required To develop shear in beam Do not delegate design of plate girder welds. (How does the fabricator know what the shear flow is?) Also, do not make these welds CJP welds. Size for actual required strength; fillet welds usually work. doubler plate stiffeners Figure 1: Diagram 1 is typical for gravity; Diagram 2 is excessive if it isn t a real loading condition. Matt Brady (brady@aisc.org) is AISC s Upper Midwest regional engineer. Cliff Schwinger (cschwinger@ harmangroup.com) is a vice president with the Harman Group. Modern STEEL CONSTRUCTION

Tip 10: Verify that framing can be installed (Figure 4). Talk to a fabricator they ll be happy you asked! Tip 20: Strive to configure details with a flat or horizontal welding position. Tip 21: Favor a longer 5 16-in. (or smaller) fillet weld over larger fillet welds; 5 16 in. is the largest fillet weld size that can be made in one pass. Multi-pass welds are three to four times more expensive than single-pass welds. Columns Tip 22: Use the deepest practical column; especially avoid W8 and smaller columns with s to the web (Figure 6). Figure 4: Framing geometry may present installation challenges. Figure 5 Do not extend stiffeners full-depth without reason Figure 6 Bolt stagger not needed for W14s Stagger bolts for W10s & W12s Single- or double-angle may fit but must be welded to beam web; avoid W8s with web s TRANSFER GIRDER BEAM OVER COLUMN Tip 11: Use one-sided shear s (like single-angle and single-plate s) to simplify field work, unless they can t provide the required strength. Tip 12: Avoid full-depth stiffeners where possible. Eliminate them, and if they re unavoidable, consider if they can be detailed to avoid fitting the stiffener (see Figure 5). Bolting Tip 13: Allow the use of bearing bolt strength values where slip-critical values are not required in the AISC and RCSC Specifications. Tip 14: Permit the use of any diameter and type of bolt, but avoid mixing grades in the same diameter. Tip 15: Permit the use of short-slotted holes, especially in shear s with the load transverse to the slot. Tip 16: Remember that all slip-critical bolted s are pretensioned, but not all pretensioned bolts need to be slipcritical. AISC 360-10, Section J1.10 has a list of s where pretensioned bolts (or welds) are required, but these are not slip-critical. Welding Tip 17: Use fillet welds sized for required strength whenever possible. Overwelding increases volume and cost proportionally to the of the weld size! Tip 18: Avoid specifying arbitrary CJP groove welds and all-around fillet welds unless they are needed to achieve the required strength. Tip 19: Favor fillet welds over groove welds. W14 W12 W10 W8 (difficult; not May have web shear problems recommended) due to large cope on bottom May not be able to install beam (depending on what s happening at the other end) Figure 7 Possible s to column web all more expensive than a standard full-depth Tip 23: Size columns to eliminate the need for stiffeners, especially for the trapped double-angle illustrated in Figure 7, which cannot be installed. Tip 24: Where column stiffeners can t be avoided, make the opposing beams the same depth, and consider the effect of the stiffeners on beams framing in the perpendicular direction. Tip 25: Orient columns to minimize skewed s (Figure 8 ). 3 skewed s 1 Inefficient skewed s to column web 3 s 1 skewed february 2014

1¾ Tip 26: Simplify base plates and anchor rod details (Figure 9). 1¾ Smallest base plate, but... Different anchor rod pattern for every base plate Unsymmetrical anchor rod pattern Fractional anchor rod spacing (based on base plate size) Beams Tip 27: Watch out for interference where beams are slightly offset from columns (Figure 10). Change the details or determine that the geometry can work before showing this on the design drawings; again, ask a fabricator, and they ll be glad you did. ROD SPACING E.W. Square plates; anchor rod patterns Space anchor rods based on column size, not base plate dimensions. Largest base plates, but... Square plates Doubly symmetric anchor rod pattern and fewer different anchor rod patterns Easier to build Figure 9: Keep column base plates and anchor rod patterns. Connection interference Figure 10 As shown on framing plan Tip 28: Increase beam depth to avoid web reinforcing (Figure 11). W14 W18 Tip 29: Size members to have sufficient strength at the net section. This usually can be accomplished by limiting the required strength to 75% of the gross section strength when the details are not known during member selection (Figure 12 ). Max. recommended stress ratio at gross section Hollow Structural Sections (HSS) Tip 30: Favor round HSS or steel pipe columns over / rectangular HSS when there are skewed s (Figure 13). = Required strength Usable strength = 0.75 (max.) Tip 31: Configure HSS framing to simplify s (Figure 14 ). HSS Cope Doubleangle NO! skewed skewed Figure 13 End plate Shim YES Figure 11 Web reinforcing plate Use deeper beam to eliminate web reinforcing plate Single plate shear conn. Thru-plate single-plate shear conn. (not necessary) Possible situations requiring web reinforcing: Large copes with heavy reactions High beams framing to low girders Skewed beams with long copes february 2014 Angle if required to prevent web buckling (If web reinforcing is required, a less expensive solution may be to use a deeper beam) YES NO!

Vertical Bracing Tip 32: Orient columns to the framing plan when they are part of a braced frame (Figure 15). Braced frame Strive for s to column flanges in braced frames Moment Connections Tip 35: Orient columns in moment frames for strong-axis bending (Figure 19 ). Efficient moment frame (all columns bending about strong axis) Braced frame Avoid skewed s to column in braced frames Inefficient columns at each end (bending about weak axis) Figure 15 Figure 16 5 16 Where column orientation cannot be changed, consider eliminating weak-axis column moment s. Weak-axis column moment details are often more complex than strong-axis column moment details FOR 14 14 W14 COLUMNS I x I y > 2.5 Single-angle or double angle brace HSS brace W shape brace Tip 33: Select efficient diagonal braces: single-angles (good for small loads), double-angles (efficient s), HSS (highest brace strength per pound of steel), W-shapes (s can be more intricate than other brace types, Figure 16). When properly selected with good details, any brace type can be economical. Tip 34: Configure slopes of diagonal braces between 35 and 55 degrees (Figures 17 and 18). Braces with shallow slopes can have difficult s Figure 17 Figure 18 Inefficient s at braces with shallow slopes Tip 36: Strong-axis beam-to-column moment s are generally less complex than weak-axis beam-to-column moment s (Figure 20). Size columns to eliminate need for stiffeners All bolted shear s BEAM-TO-COLUMN FLANGE MOMENT CONNECTION Note: If columns were upsized to control drift, they may already be large enough to eliminate the need for stiffeners Fitted T&B flange plates heavy girder Extended singleplate shear BEAM-TO-COLUMN WEB MOMENT CONNECTION Figure 20 Figure 21: Where girder moments are big and column moments are small, consider running girders continuous through columns. The closer braces are to 45, the more compact the s will be Tip 37: Consider making girders continuous through columns at heavy moment-connected girders to simplify flow of moment through columns (Figure 21). Ask the fabricator, since the gain needs to outweigh the difference in construction to make this tip viable. Modern STEEL CONSTRUCTION

Tip 38: Run cantilevered roof beams over the tops of columns (Figure 22). Cantilever Cantilever Tip 42: Configure framing so that no more than one beam frames to any one side of a column (Figures 26 and 27). Do not do this! Weld s to beam webs (to avoid bolt interference) Flange interference YES! NO! Figure 22: Note: If roof framing slopes, coordinate so there s not a kink in the beam at the column. Tip 39: Avoid skewed beam-to-column moment s (Figure 23). Tip 40: Beams with flange-bolted moment s must have sufficiently wide flanges to install bolts (Figure 24). Many light beams do not have wide enough flanges! 3½ Figure 26 Figure 27 Non-standard bent plate Big cope; check web buckling Web reinforcing, if required Tip 43: Head off steeply skewed s (Figure 28 ). Steep skewed s can be a problem with, Small beams (long copes realitive to depth) Big beams with large reactions Add header beam Steep skewed Figure 23: Difficult to detail. Figure 24: Min. recommended flange width to install bolts through flange = 6. (Don t forget to check net section.) Min. gage for installation of 7 8 Ø bolts through flanges Long cope; possible need for web reinforcing; difficult to install bolts in web of supported beam Problem More constructable (smaller skew, smaller cope) Tip 44: Configure framing to minimize skewed s (Figure 29 ). Solution Framing Tip 41: Frame members with very large reactions to columns preferably to the flanges (Figure 25 ). Square Connection february 2014 no welds Double angle Conn. w/ ½ THK. angles & 10 rows of 7 8 Ø A490N bolts fillet welds w36 150, v u =490k 1 pl. w/ (20)- 1 Ø A490N bolts CJP weld 1 pl. (ASTM A572, GR 50) w/ (40)-1 Ø A490N bolts Skewed Connections @ E.E. Skewed Connection

Tip 45: Configure framing to minimize the number of beams (Figure 30 ). Tip 46: Maximize slab span to minimize the number of beams (Figure 31). Tip 47: Minimize the gingerbread extra small pieces of steel (Figure 32). 20 Fewer beams Fewer s Fewer crane picks Miscellaneous topics Tip 48: Avoid torsion in W shapes. Tip 49: Use R=3 and the associated basic seismic design without AISC 341 requirements, when possible. Tip 50: Use camber intelligently. It often is more economical to design stiffer floors without camber. 40 30 Benefits 30 6-0 10-0 5 SLAB 6½ SLAB Fewer pieces Less steel weight (usually) Fewer s Fewer crane picks More tributary area per beam = greater LL reduction More mass per beam = Less vibration Thicker slab = greater composite beam M n (1½ DECK + 3½ L.W. CONCRETE) Figure 31 Figure 32 Turning deck eliminates these small beams (3 DECK + 3½ L.W. CONCRETE) Remember: The more choices the fabricator, erector and design engineer have available to them and the earlier in the process they are able to provide input the more likely they are to provide better solutions. Engage them early and they ll help enhance your project s constructability and success. Want more constructability and economy tips? You can view the related SteelDay 2012 webinar for free (and receive free CEUs or PDHs) at www.aisc.org/50tips. You can also view the related 2013 NASCC presentation at www.aisc. org/50tipsmedia. And Cliff Schwinger will be presenting sessions at this year s NASCC: The Steel Conference, March 26-28 in Toronto, as well. Visit www.aisc.org/nascc to register and find out more about the show. Modern STEEL CONSTRUCTION