Scope of Accreditation For Retlif Testing Laboratories 795 Marconi Avenue Ronkonkoma NY 11779 Robert Lenker 215-256-4133 x360 In recognition of a successful assessment to ISO/IEC 17025:2005 and the requirements of the LABPR 406 Electromagnetics Compatibility & Telecommunications Laboratory Accreditation Program (EMC & T LAP), accreditation is granted to Retlif Testing Laboratories to perform the following tests: Accreditation granted through: September 2, 2019 Testing Electrical - EMC / EMI Measurement of Radio-Noise Emissions From Low-Voltage Electrical and Electronic Equipment 9 khz to 18 GHz ANSI C63.4:2003 ANSI C63.4:2009 ANSI C63.4:2014 Testing - Mechanical Acceleration MIL-STD 202F (212A) MIL-STD 202G (212A) MIL-STD 750D (2006) MIL-STD 750E (2006) MIL-STD 810B (513) MIL-STD 810C (513.2) MIL-STD 810D (513.3) MIL-STD 810E (513.4) MIL-STD 810F (513.5) MIL-STD 810G (513.6) MIL-STD 883E (2001.2) MIL-STD 883F (2001.2) RTCA-DO 160C (7) RTCA-DO 160D (7) RTCA-DO 160E (7) RTCA-DO 160F (7) RTCA-DO 160G (7) Form 28.6 Revision 5 05/23/06 Page 1 of 8
Altitude / Barometric Pressure (Including Explosive Decompression) (up to 400 000) ft (5X10E -6 ) MIL-STD 202F (105C) MIL-STD 202G (105C) MIL-STD 750D (1001.1) MIL-STD 750E (1001.2) MIL-STD 810B (500) MIL-STD 810C (500.1) MIL-STD 810D (500.2) MIL-STD 810E (500.3) MIL-STD 810F (500.4) MIL-STD 810G (500.5) MIL-STD 883E (1001) MIL-STD 883F (1001) RTCA-DO 160C (4) RTCA-DO 160D (4) RTCA-DO 160E (4) RTCA-DO 160F (4) RTCA-DO 160G (4) GR-63-CORE (4.1.3) High / Low Temperature Chamber Volumes: (up to 1 000) ft 3 (10 X 10 X 10 ) Temperature Range: (-200 to 1 200) ºC Transition Rate: (up to 20)ºC/Min MIL-STD 202F (108A) MIL-STD 202G (108A) MIL-STD 810B (501), (502) MIL-STD 810C (501.1), (502.1) MIL-STD 810D (501.2), (502.2) MIL-STD 810E (501.3), (502.3) MIL-STD 810F (501.4), (502.4) MIL-STD 810G (501.5), (502.5) MIL-STD 883E (1010.7) MIL-STD 883F (1010.8) RTCA-DO 160C (4), (5) RTCA-DO 160D (4), (5) RTCA-DO 160E (4), (5) RTCA-DO 160F (4), (5) RTCA-DO 160G (4), (5) EN 60068-2-1 EN 60068-2-2 GR-63-CORE (5.1.1.1), (5.1.1.2) IEC 60945 (8.2), (8.4) IEC 68-2-14 IEC 60068-2-14 Lloyds Register 1996 (17), (18) SAE J1455 (4.1) Form 28.6 Revision 5 05/23/06 Page 2 of 8
Humidity / Moisture Resistance Shock Mechanical (2 to 98) % RH Force: (Up to 40 000) lbf Waveforms: Half Sine, Sawtooth (Terminal Peak), Trapezoidal, Square Wave, Haversine, Triangle, SRS Maximum Level: (1 to 5 000) g s MIL-STD 202F (103B), (106F) MIL-STD 202G (103B), (106G) MIL-STD 750D (1021.2) MIL-STD 750E (1021.3) MIL-STD 810B (507) MIL-STD 810C (507.1) MIL-STD 810D (507.2) MIL-STD 810E (507.3) MIL-STD 810F (507.4) MIL-STD 810G (507.5) MIL-STD 883E (1004.7) MIL-STD 883F (1004.7) RTCA-DO 160C (6) RTCA-DO 160D (6) RTCA-DO 160E (6) RTCA-DO 160F (6) RTCA-DO 160G (6) EN 60068-2-30 GR-63-CORE (5.1.1.3), (5.1.2) IEC 60945 (8.3) Lloyds Register 1996 (14), (15) SAE J1455 (4.2) MIL-STD 202F (207A), (213B) MIL-STD 202G (207B), (213B) MIL-STD 750D (2016.2) MIL-STD 750E (2016.2) MIL-STD 810B (516) MIL-STD 810C (516.2) MIL-STD 810D (516.3) MIL-STD 810E (516.4) MIL-STD 810F (516.5) MIL-STD 810G (516.6) MIL-S-901C MIL-S-901D MIL-STD 883E (2002.3), (2007.2), (2026) MIL-STD 883F (2002.4), (2007.3) (2026) RTCA-DO 160C (7) RTCA-DO 160D (7) RTCA-DO 160E (7) RTCA-DO 160F (7) RTCA-DO 160G (7) EN 60068-2-27 IEC 60945 (8.6) SAE J1455 (4.10) Form 28.6 Revision 5 05/23/06 Page 3 of 8
Shock Thermal High Temperature: (Up to 180) o C Low Temperature: (Down to -80) o C MIL-STD 202F (107G) MIL-STD 202G (107G) MIL-STD 750D (1051.5) MIL-STD 750E (1051.6) MIL-STD 810B (503) MIL-STD 810C (503.1) MIL-STD 810D (503.2) MIL-STD 810E (503.3) MIL-STD 810F (503.4) MIL-STD 810G (503.5) MIL-STD 883E (1011.9) MIL-STD 883F (1011.9) SAE J1445 (4.1.3.2) Fungus Test Area: (up to 27) ft 3 (3 X 3 X 3 ) MIL-STD 810B (508) MIL-STD 810C (508.1) MIL-STD 810D (508.3) MIL-STD 810E (508.4) MIL-STD 810F (508.5) MIL-STD 810G (508.6) RTCA-DO 160C (13) RTCA-DO 160D (13) RTCA-DO 160E (13) RTCA-DO 160F (13) RTCA-DO 160G (13) Rain / Waterproofness (0 to 100) mph (0.2 to 10) in/hour MIL-STD 810B (506) MIL-STD 810C (506.1) MIL-STD 810D (506.2) MIL-STD 810E (506.3) MIL-STD 810F (506.4) MIL-STD 810G (506.5) RTCA-DO 160C (10) RTCA-DO 160D (10) RTCA-DO 160E (10) RTCA-DO 160F (10) RTCA-DO 160G (10) IEC 60529 (14.2.4a) IEC 60945 (8.8) NEMA 250 (5.3), (5.4) UL 50 (30) Ballistic Shock MIL-STD 810F (522) MIL-STD 810G (522.1) 901 Shock MIL-S 901C MIL-S 901D Form 28.6 Revision 5 05/23/06 Page 4 of 8
Salt Spray / Fog Chamber Size: (up to 256) ft 3 (8 X 4 X 8 ) MIL-STD 202F (101D) MIL-STD 202G (101E) MIL-STD 750D (1041.3), (1046.2) MIL-STD 750E (1041.3), (1046.3) MIL-STD 810B (509) MIL-STD 810C (509.1) MIL-STD 810D (509.2) MIL-STD 810E (509.3) MIL-STD 810F (509.4) MIL-STD 810G (509.5) MIL-STD 883E (1009.8) MIL-STD 883F (1009.8) RTCA-DO160C (14) RTCA-DO 160D (14) RTCA-DO 160E (14) RTCA-DO 160F (14) RTCA-DO 160G (14) ASTM B117; ASTM G85 IEC 60945 (8.12) Lloyds Register 1996 (16) NEMA 250 (5.8) (5.9) SAE J1455 (4.3) UL 50 (38) (39) Icing / Freezing Rain Immersion (0 to 100) mph (0.2 to 10) in/hour MIL-STD 810D (521) MIL-STD 810E (521.1) MIL-STD 810F (521.2) MIL-STD 810G (521.3) RTCA-DO 160C - (24), (A, B, C) RTCA-DO 160D - (24), (A, B, C) RTCA-DO 160E - (24), (A, B, C) RTCA-DO 160F - (24), (A, B, C) RTCA-DO 160G - (24), (A, B, C) GR-63-CORE (34) NEMA 250 (5.6) MIL-STD 202F (104A) MIL-STD 202G (104A) MIL-STD 750D (1011) MIL-STD 750E (1011.1) MIL-STD 810B (512) MIL-STD 810C (512.1) MIL-STD 810D (512.2) MIL-STD 810E (512.3) MIL-STD 810F (512.4) MIL-STD 810G (512.5) MIL-STD 883E (1002) MIL-STD 883F (1002) IEC 60945 (8.9) Form 28.6 Revision 5 05/23/06 Page 5 of 8
Explosive Atmosphere Chamber Volume: (77) ft 3 Altitude: (up to 60 000) ft MIL-STD 202F (109B) MIL-STD 202G (109C) MIL-STD 810B (511) MIL-STD 810C (511.1) MIL-STD 810D (511.2) MIL-STD 810E (511.3) MIL-STD 810F (511.4) MIL-STD 810G (511.5) RTCA-DO 160C (9) RTCA-DO 160D (9) RTCA-DO 160E (9) RTCA-DO 160F (9) RTCA-DO 160G (9) Sand & Dust Sand Chamber: Test Area - (up to 5 X 5) ft 2 Velocities: (up to 5 700) ft / min Dust Chamber: Test Area (up to 4 X 4) ft 2 MIL-STD 810B (510) MIL-STD 810C (510.1) MIL-STD 810D (510.2) MIL-STD 810E (510.3) MIL-STD 810F (510.4) MIL-STD 810G (510.5) MIL-STD 202F (110A) MIL-STD 202G (110A) RTCA-DO 160C (12) RTCA-DO 160D (12) RTCA-DO 160E (12) RTCA-DO 160F (12) RTCA-DO 160G (12) IEC 60529, 2001 Para 13 IPX6 NEMA 250 (5.5.1.3) Terminal Strength MIL-STD 202F (211A) MIL-STD 202G (211A) MIL-STD 750D (2036.4) MIL-STD 750E (2036.4) Resistance to Solvents MIL-STD 202F (215J) MIL-STD 202G (215K) MIL-STD 750D (1022.5) MIL-STD 750E (1022.5) MIL-STD 810G (504.1) Fluid Susceptibility RTCA-DO 160C (11) RTCA-DO 160D (11) RTCA-DO 160E (11) RTCA-DO 160F (11) RTCA-DO 160G (12) IEC 60945 (8.11) Form 28.6 Revision 5 05/23/06 Page 6 of 8
Insulation Resistance MIL-STD 202F (302) MIL-STD 202G (302) MIL-STD 750D (1016) MIL-STD 750E (1016) Solderability MIL-STD 202F (208H) MIL-STD 750D (2026.10) MIL-STD 750E (2026.11) Inclination Hi Potential Testing 6 x 6 Table (up to 3 000) lb Static & Dynamic (Up to 5 000) V AC/DC 46-CFR-162.060.30 MIL-STD 202G (301) Level: (10 to 17 000) g Pyrotechnic Shock Frequency Range: (10 to 10 000) Hz MIL-STD 810F (517) MIL-STD 810G (517.1) Displacement: (2) in Peak-to-Peak Form 28.6 Revision 5 05/23/06 Page 7 of 8
Testing - Vibration Vibration Random and Sinusoidal Force Rating: (20 000) lbf Displacement: (2) in Peak-to-Peak Frequency Range: Random (4 to 3 000) Hz Sinusoidal (4 to 10 000) Hz Maximum Level: Random (100) g rms Sinusoidal (160) g Sine Velocity: Intermittent Duty (100) in/sec Continuous Duty (80) in/sec MIL-STD 202F (201A), (204D) (214A) MIL-STD 202G (201A), (204D) (214A) MIL-STD 750D (2046.1), (2056) (2057.1) MIL-STD 750E (2046.2), (2056) (2057.2) MIL-STD 810B (514), (519) MIL-STD 810C (514.2), (519.2) MIL-STD 810D (514.3), (519.3) MIL-STD 810E (514.4), (519.4) MIL-STD 810F (514.5), (519.5) MIL-STD 810G (514.6), (519.6) MIL-STD 883E (2005.2) MIL-STD 883F (2005.2) MIL-STD 167-1A RTCA-DO 160C (8) RTCA-DO 160D (8) RTCA-DO 160E (8) RTCA-DO 160F (8) RTCA-DO 160G (8) EN 60068-2-6 GR-63-CORE (5.4.2), (5.4.3) IEC 60945 (8.7) Lloyds Register 1996 (12), (13) SAE J1455 (4.9) Notes: 1) This laboratory offers commercial testing service. 2) Testing also performed using customer specified test methods based on the technologies listed above. Approved by: Date: September 2, 2016 R. Douglas Leonard Chief Technical Officer Re-issued: 9/2/16 Revised 8/14/17 Form 28.6 Revision 5 05/23/06 Page 8 of 8