Thermoelectric Coolers. All Models INSTRUCTION MANUAL. Rev. G 2016 Pentair Equipment Protection P/N

Similar documents
Thermoelectric Cooler

PAGODA SERIES OPERATOR'S MANUAL

MTTC User Manual. Innovative Technology for a Connected World. General Description. Specifications and features

OPERATION AND INSTALLATION MANUAL

KNHE20 SERIES WATER-TO-AIR HEAT EXCHANGER

KPHE20 SERIES WATER-TO-AIR HEAT EXCHANGER

Field Economy Unit Instruction Manual

Signal Follower Card. Instruction Manual Model C

10810 W. LITTLE YORK RD. #130 - HOUSTON, TX VOICE (713) FAX (713) web: IMPORTANT!!!

Quick-Start Operating Guide Document No Process Gas Cooler Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web: twrlighting.com IMPORTANT!!!

Wash Down Duty Non-Contact Sensor

ADVANTAGE SENTRY SERIES FILTER FAN OPERATOR'S MANUAL

10810 W. LITTLE YORK RD. #130 - HOUSTON, TX VOICE (713) FAX (713) web: IMPORTANT!!!

Dancer Duty Potentiometer

GUARDIAN SERIES FILTER FAN OPERATOR'S MANUAL

WheelTime Exchange Standard Terms and Conditions. ZF Services North America, LLC (ZFSNA) 9/1/2015 ZF SACHS Heavy Duty Clutch and Shocks

TERMS AND CONDITIONS OF SALE

Process Returns in VOTW

XBDM-HW63. 63A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

TL-600 MOBILE PHASE HEATER

Hayward Flow Control

Installation Guide Document No Transaction Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised October 2017

FROST TOP - WF SERIES

END TRUCKS WHEEL SIZES: 9", 12", 15" & 18"

CMR Quick Start Guide. CMR-5975 Digicast Media Router (MR-S2) Part Number MN-CMR5975-QSG REV. 3

P R I C E L I S T 1

Global Water Instrumentation, Inc.

P1902 Installation Manual

Address: City: State: Zip: Day Phone: Fax: 5. Where Were Your Products Purchased and/or Installed: Installer s Name/Company:

MiT. MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE. MPL Digital Pedestal. Manual Version 0.2

TERMS AND CONDITIONS: (Stated in U.S. Dollars):

Qualstar Technical Support

Installation Guide Document No Fire-Rated Pass-throughs Copyright 2017 Terra Universal Inc. All rights reserved. Revised Sept.

WARRANTY GENERAL POLICY AND RETURN GOODS PROCEDURE. For Original Equipment Manufacturers Only

10810 W. LITTLE YORK RD. #130 - HOUSTON, TX VOICE (713) FAX (713) web: IMPORTANT!!!

Miniglaze/2. Owner & Operator's Manual PORCELAIN STAINING AND GLAZING FURNACE. Model No: Voltage: V 50/60Hz V 50/60Hz

General Information. Southwest Office Edwards Road, Suite B105 Cerritos, CA (Main Phone)

APC Step-Down Transformer. Models: AP9626, AP9627, and AP9628

Aero Tec Models 700 & 750 (115 vac)

Lithonia Lighting Terms and Conditions of Sale

Effective This guide supersedes all previous versions

Drive Services Policy and Warranty Information

TERMS AND CONDITIONS May 15, 2017

Beach House Cargo Lifts Branded Product of Cargo Lift Distributors

Infant Warmer Care Station Cabinet Light

STEEL PIPE NIPPLES SEAMLESS Price Sheet PNS-9.16C Effective: September 5, 2016 Cancels Price Sheet PNS-10.15C of October 5, 2015

3601 E. 34th St. Tucson, AZ USA Tel Fax Web:

Installation, Operating and Maintenance Instructions Incognito Series Air Curtain

Drag Chain Conveyor Installation and Operation Manual

WARNING. Introduction ! ATTENTION

92831 TEL: (714) FAX:

Installation Guide Document No BioSafe Cleanroom Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised December 2017

Eaton Drives Warranty & Commercial Exchange Policy - Supplement to Selling Policy

Global Water Instrumentation, Inc.

Model 3185E DUAL TONE DECODER INSTRUCTION MANUAL

PORTABLE CHAIR SCALES BEAM and DIGITAL TYPES MODELS 475, 4751, 6475, 6475k and 6475KGEU

User Guide M Rev A 09/15

E3X-DRT21/SRT21/CIF11

92831 TEL: (714) FAX:

C60 Standby UPS. 800VA Models. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

92831 TEL: (714) FAX:

Locking Systems International Inc.

Derive Systems, Inc. Pricing, Ordering and Returns Policy

Ecologix Environmental Systems, LLC

TABLE OF CONTENTS. Section Paragraph Title Page. ADDENDUM Visual Index Quick Reference. 1 General Information 1-1

Quick-Start Operating Guide Document No Exhaust Fume Hood Copyright 2010 Terra Universal Inc. All rights reserved. Revised September 2010

OMNICON Antibiotic Potency Testing

INSTALLATION PROCEDURE

Model 292A. Surface Resistance Test Kit. Instruction Manual

MANUAL ENGLISH. Ordercode: D3423/D3423W. Highlite International B.V. Vestastraat EX Kerkrade the Netherlands

To Contact PS DOORS:

4-Wire Buffer Amplifier. User Manual

Lighting Services Inc. QuickShipExpress 5-10 Day Service

MANUAL. ENGLISH Antenna Booster Ordercode: D1425. Highlite International B.V. Vestastraat EX Kerkrade the Netherlands

Inland Building Systems Field Policy

Products. Standard Terms, Conditions, Policies and Procedures Guide. Residential Garage Door Openers and Accessories

Dynatronics Parallel Bars

ITDG Independent Tire Dealers Group. Volume Bonus Program. (Revised 3/27/2012)

ASTM D 991 TEST FIXTURE

POLICY AND PROCEDURE MANUAL

EP-CORKEL2 OWNER S MANUAL

Model T2642E Wall Mount. Television Wall Mount with Tilt Option

NOTICE: To the prices and terms quoted, there will be added any manufacturers or sales tax payable on the transaction under any effective statute.

NOTICE: To the prices and terms quoted, there will be added any manufacturers or sales tax payable on the transaction under any effective statute.

Stretch Wire. P/N Rev. 2. IOM Stretched wire festoon manual

OEM Policy. Information for Original Equipment Manufacturers

ORDER DESK TOLL FREE (800) SIGMA SWITCHES PLUS

Global Water globalw.com. Global Water. Instrumentation, Inc.

MODELS MB1K-1, MB1K-2 MB2K-1, MB2K-2 MB3K-1, MB3K-2

New Advanced Environmental Air Treatment System

Rack Power Distribution Unit AP7562, AP7563, AP7564 General Information

PS-31 (SUS304, 300 mm) PS-31 (SUS304, 1,000 mm)

Kennedy Valve. A Division of McWane, Inc. AWWA PRODUCTS

OWNER S MANUAL SERIES MDS-96-BK, SM, DR

AQUA UNO TUB DOOR INSTALLATION INSTRUCTIONS

OWNER S MANUAL SERIES MDS-96-BK, SM, DR

1. DEFINITIONS 2. ORDERS, PRICES AND FEES

STEEL PIPE NIPPLE DISCOUNT SHEET

P420. Installation and Operation Manual. Plastic Vortex Shedding Flowmeters. Series: P420

Transcription:

Thermoelectric Coolers All Models INSTRUCTION MANUAL Rev. G 2016 Pentair Equipment Protection P/N 89072602 89072603

TABLE OF CONTENTS RECEIVING THE THERMOELECTRIC COOLER...3 HANDLING & TESTING THE THERMOELECTRIC COOLER...3 INSTALLATION INSTRUCTIONS...4 Design Data... 4 Dimensional Drawing (TE090624020)... 5 Dimensional Drawing (TE121024020)... 6 Dimensional Drawing (TE121048020)... 7 Dimensional Drawing (TE162024020)... 8 Dimensional Drawing (TE162048020)... 9 Dimensional Drawing (TE090624010)... 10 Dimensional Drawing (TE121024010)... 11 Dimensional Drawing (TE121048010)... 12 Dimensional Drawing (TE162024010)... 13 Dimensional Drawing (TE162048010)... 14 Dimensional Drawing (TE090624011)... 15 Dimensional Drawing (TE121024011)... 16 Dimensional Drawing (TE162024011)... 17 Wiring Diagrams 24 Units... 18 Wiring Diagrams 48 Units... 19 PRINCIPLES OF OPERATION...20 MAINTENANCE...20 WARRANTY...22 RETURN AND REPAIR POLICY... 22 LIMITATION OF LIABILITY... 23-2 - 2016 Pentair Equipment Protection 89072603

RECEIVING THE THERMOELECTRIC COOLER Inspect the thermoelectric cooler. Check for concealed damage that may have occurred during shipment. Look for dents, scratches, loose assemblies, etc. Damage evident upon receipt should be noted on the freight bill. Damage should be brought to the attention of the delivering carrier -- NOT to Pentair Equipment Protection -- within 15 days of delivery. Save the carton and packing material and request an inspection. Then file a claim with the delivering carrier. Pentair Equipment Protection cannot accept responsibility for freight damages; however, we will assist you in any way possible. HANDLING & TESTING THE THERMOELECTRIC COOLER TEST FOR FUNCTIONALITY BEFORE MOUNTING THE THERMOELECTRIC COOLER TO THE ENCLOSURE. Refer to nameplate for proper electrical current requirements, then connect power cord to a properly grounded power supply. Minimum circuit ampacity should be at least 125% of the amperage shown in the design data section for the appropriate model. No other equipment should be connected to this circuit to prevent overloading. Operate the thermoelectric cooler for five (5) to ten (10) minutes. No excessive noise or vibration should be evident during this run period. The ambient and enclosure fans should be running. 2016 Pentair Equipment Protection 89072603-3 -

INSTALLATION INSTRUCTIONS 1. Inspect thermoelectric cooler. Verify functionality before mounting the thermoelectric cooler, see HANDLING & TESTING THE THERMOELECTRIC COOLER on page 3. 2. Using the cutout dimensions shown in this manual, prepare the air openings, and mounting bolt hole pattern for the enclosure. 3. Mount thermoelectric cooler on enclosure using mounting fasteners provided. 4. Refer to top of nameplate for electrical requirements. Connect the thermoelectric cooler to a properly grounded power supply. Class 2 or SELV power source is required for fans. DESIGN DATA Model Description Voltage TE090624020 TE121024020 TE121048020 TE162024020 TE162048020 TE090624010 TE121024010 TE121048010 TE162024010 TE162048010 TE090624011 TE121024011 TE162024011 60 Watt 24 Volt TEC No Shroud 100 Watt 24 Volt TEC No Shroud 100 Watt 48 Volt TEC No Shroud 200 Watt 24 Volt TEC No Shroud 200 Watt 48 Volt TEC No Shroud 60 Watt 24 Volt TEC Galvanized Shroud 100 Watt 24 Volt TEC Galvanized Shroud 100 Watt 48 Volt TEC Galvanized Shroud 200 Watt 24 Volt TEC Galvanized Shroud 200 Watt 48 Volt TEC Galvanized Shroud 60 Watt 24 V TEC Stainless Steel Shroud 100 Watt 24 V TEC Stainless Steel Shroud 200 Watt 24 V TEC Stainless Steel Shroud 18-27.6 18-27.6 40-56.7 18-27.6 40-56.7 18-27.6 18-27.6 40-56.7 18-27.6 40-56.7 18-27.6 18-27.6 18-27.6 Rated Amps at 131F/131F Nominal Cooling/ Heating Watts Maximum Ambient Temperature F / C Shipping Weight lb. / kg 4.4 @ 27.6 52 / 64 131 / 55 7.5 / 3.4 8.5 @ 27.6 94 / 94 131 / 55 10.8 / 4.9 4.4 @ 56.7 94 / 94 131 / 55 10.8 / 4.9 14.7 @ 27.6 166 / 144 131 / 55 16.9 / 7.7 7.6 @ 56.7 166 / 149 131 / 55 16.9 / 7.7 4.4 @ 27.6 52 / 64 131 / 55 9.3 / 4.3 8.5 @ 27.6 94 / 94 131 / 55 13.3 / 6.1 4.4 @ 56.7 94 / 94 131 / 55 13.3 / 6.1 14.7 @ 27.6 166 / 144 131 / 55 20.7 / 9.4 7.6 @ 56.7 166 / 149 131 / 55 20.7 / 9.4 4.4 @ 27.6 52 / 64 131 / 55 9.3 / 4.3 8.5 @ 27.6 94 / 94 131 / 55 13.3 / 6.1 14.7 @ 27.6 166 / 144 131 / 55 20.7 / 9.4-4 - 2016 Pentair Equipment Protection 89072603

DIMENSIONAL DRAWING (TE090624020) 2016 Pentair Equipment Protection 89072603-5 -

DIMENSIONAL DRAWING (TE121024020) 89062631-6 - 2016 Pentair Equipment Protection 89072603

DIMENSIONAL DRAWING (TE121048020) 89062632 2016 Pentair Equipment Protection 89072603-7 -

DIMENSIONAL DRAWING (TE162024020) 89062256-8 - 2016 Pentair Equipment Protection 89072603

DIMENSIONAL DRAWING (TE162048020) 89062117 2016 Pentair Equipment Protection 89072603-9 -

DIMENSIONAL DRAWING (TE090624010) - 10-2016 Pentair Equipment Protection 89072603

DIMENSIONAL DRAWING (TE121024010) 89068328 2016 Pentair Equipment Protection 89072603-11 -

DIMENSIONAL DRAWING (TE121048010) 89068329-12 - 2016 Pentair Equipment Protection 89072603

DIMENSIONAL DRAWING (TE162024010) 89068330 2016 Pentair Equipment Protection 89072603-13 -

DIMENSIONAL DRAWING (TE162048010) 89068331-14 - 2016 Pentair Equipment Protection 89072603

DIMENSIONAL DRAWING (TE090624011) 2016 Pentair Equipment Protection 89072603-15 -

DIMENSIONAL DRAWING (TE121024011) 89068333-16 - 2016 Pentair Equipment Protection 89072603

DIMENSIONAL DRAWING (TE162024011) 89068334 2016 Pentair Equipment Protection 89072603-17 -

WIRING DIAGRAMS 24 VDC UNITS NOTE: Class 2 or SELV power source is required for fans. - 18-2016 Pentair Equipment Protection 89072603

WIRING DIAGRAMS 48 VDC UNITS For -48 Positive Ground Telecom Power Supply: NOTE: Class 2 or SELV power source is required for fans. 2016 Pentair Equipment Protection 89072603-19 -

PRINCIPLES OF OPERATION The thermoelectric cooler is configured for direct power application through the input connections on the terminal block. The terminal block is located on the enclosure side of the product. The thermoelectric cooler can be used for cooling or heating and is determined by the DC voltage polarity applied for the peltier modules at the terminal block. Refer to the wiring diagrams for the correct wire connections depending on the desired operating condition. Note the fan wiring will not change to match the peltier module wiring. The fan wiring is the same regardless of whether the thermoelectric cooler is configured for cooling or heating. MAINTENANCE Beyond occasional inspection for dust or dirt buildup no special maintenance should be required. - 20-2016 Pentair Equipment Protection 89072603

NOTES 2016 Pentair Equipment Protection 89072603-21 -

WARRANTY Pentair Equipment Protection warrants that the Goods manufactured by Pentair Equipment Protection will be free from defects in material and workmanship for a period of one (1) year from the date of shipment by Pentair Equipment Protection, subject to the following conditions and exclusions: A. Conditions. All Goods must be installed and operated according to the following specifications: 1. Maximum voltage variation no greater than plus or minus 10% of nameplate nominal rating; 2. Maximum frequency variation no greater than plus or minus 3 Hz of nameplate nominal rating; 3. Must not exceed minimum and maximum stated temperatures on the nameplate; 4. Must not exceed (BTU/Hr) rating, including any heat sink as indicated on the nameplate; 5. Refrigerant bearing Goods must not be restarted for a period of one (1) minute after intentional or accidental shut-off; 6. The filters (if applicable) must be cleaned regularly; 7. The Goods and any parts thereof must not be modified, unless prior written authorization is received from Pentair Equipment Protection; and 8. All Goods must be installed and grounded in accordance with all relevant electrical and safety codes, as well as the National Electric Code and OSHA rules and regulations. 9. All Goods must be installed in a stationery application, free of vibration. A violation of any one of these conditions shall render the warranty hereunder void and of no effect. B. Exclusions. This warranty shall be void if product is misapplied in any way or: 1. Buyer specified product is inappropriate for system or environment in which it is operating. 2. Goods are not installed in accordance with Pentair Equipment Protection specifications. 3. Removal or modification of Pentair Equipment Protection label affixed to product without written Pentair Equipment Protection approval. Pentair Equipment Protection must be notified of a claim in writing not later than fourteen (14) days from the date when Buyer has become aware of such occurrence, or where the defect is such that it may cause damage, immediately, such notice containing a description of how the defect manifests itself. Failure to provide such prompt notice to Pentair Equipment Protection shall result in forfeiture of Buyer s rights under this warranty. In the event of a warranty claim, Buyer is to return defective goods to Pentair Equipment Protection in accordance with Pentair Equipment Protection Return Policy. Warranty period for repaired goods remains at 1 year from shipment of original goods. Pentair Equipment Protection sole obligation to Buyer under this warranty will be, at Pentair Equipment Protection option: A. Repair or replace Pentair Equipment Protection products or parts found to be defective in material or workmanship. B. Issue credit for the purchase price paid by Buyer relating to such defective Goods or part. THIS WARRANTY CONSTITUTES THE ENTIRE WARRANTY WITH RESPECT TO THE GOODS AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY AND IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. RETURN AND REPAIR POLICY Pentair Equipment Protection products that: (i) are made to order, (ii) have been modified by Buyer, (ii) have special finishes, or (iv) are determined by Pentair Equipment Protection to constitute custom products that cannot be returned to stock or resold to other Buyers, will not be accepted for return by Pentair Equipment Protection. All returns require a Return Material Authorization number (RMA #), regardless of reason for return, whether it be for warranty or out of warranty repair. Returns without an RMA # will be refused by our Receiving Department. An RMA # is valid for 30 days. - 22-2016 Pentair Equipment Protection 89072603

A. An RMA # will be issued by our Product Return Department in Anoka, MN at 763-422-2211. Buyer should have following information available at time of RMA request: 1. Complete Model Number, Serial Number and description of damaged unit being returned. 2. Original Buyer Purchase Order number and date product was received by Buyer. 3. Quantity to be returned and a brief description of failure for each unit, if different. 4. Contact information of Buyer that must include: name of company, billing and shipping address, phone, number, fax number, freight carrier and the name and phone number of a Buyer contact who can elaborate on the claimed defect in detail. 5. Buyer must provide a Repair Purchase Order number for both warranty and out of warranty repairs. The PO will not exceed 50% of a new unit. Buyer will be notified of repair charges that exceed approved PO amount. B. All returns to Pentair Equipment Protection must be securely packed, using original cartons if possible. All returns must have the RMA number visible on the outside of the carton. Pentair Equipment Protection is not responsible for material damaged in transit. Any refrigerant-bearing Goods must be shipped upright for return. C. Shipping cost for all non-warranty repairs is the responsibility of the sender and must be shipped prepaid. Shipping costs for all warranty related repairs will be covered by Pentair Equipment Protection provided the goods are returned using a Pentair Equipment Protection approved carrier. If after diagnoses the product is determined by Pentair Equipment Protection not be covered under warranty, Buyer will be responsible for all shipping charges and will be billed accordingly. D. Non-warranty repairs are subject to a $105 minimum analysis fee. If approval is not received within 30 days, material will be scrapped and all shipping expenses and corresponding analysis fees will be billed to Buyer. E. At Buyer s request, Failure Analysis can be provided by Pentair Equipment Protection for warrantable goods at no charge. Failure analysis for non-warranty repairs are subject to a $150 per hour Engineering charge plus any other incurred testing costs. F. All returned merchandise must be sent to the following address: Pentair Equipment Protection, 2100 Hoffman Way, Anoka, MN 55303-1745. G. Credit for accepted returns shall be at the original selling price or the current selling price, whichever is lower, less the restocking charge indicated as follows: 1. Within 60 days of invoice date - 20% of applicable selling price. 2. Within 61-120 days of invoice date - 30% of applicable selling price. 3. Within 121-180 days of invoice date - 40% of applicable selling price. 4. Beyond 180 days - subject to individual review by Pentair Equipment Protection. If product being returned for credit requires repair or modification, the cost of any labor or material necessary to bring product into saleable condition will be deducted from credit. Buyer may not take credit against returns without prior written Pentair Equipment Protection approval. LIMITATION OF LIABILITY PENTAIR EQUIPMENT PROTECTION WILL NOT BE LIABLE UNDER ANY CIRCUMSTANCES FOR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES, INCLUDING WITHOUT LIMITATION ANY LOST PROFITS OR LABOR COSTS, ARISING FROM THE SALE, USE OR INSTALLATION OF THE GOODS, FROM THE GOODS BEING INCORPORATED INTO OR BECOMING A COMPONENT OF ANOTHER PRODUCT, FROM ANY BREACH OF THIS AGREEMENT OR FROM ANY OTHER CAUSE WHATSOEVER, WHETHER BASED ON WARRANTY (EXPRESSED OR IMPLIED) OR OTHERWISE BASED ON CONTRACT, OR ON TORT OR OTHER THEORY OF LIABILITY, AND REGARDLESS OF ANY ADVICE OR REPRESENTATIONS THAT MAY HAVE BEEN RENDERED BY PENTAIR EQUIPMENT PROTECTION CONCERNING THE SALE, USE OR INSTALLATION OF THE GOODS. 2016 Pentair Equipment Protection 89072603-23 -

Pentair Equipment Protection 2100 Hoffman Way Minneapolis, MN 55303 USA +1.763.422.2211 +1.763.576.3200 PentairProtect.com 2016 Pentair Equipment Protection 89072603 Rev. G P/N 89072602