Agilent Ultimate Plus Fused Silica Tubing

Similar documents
A Rapid Method for Trace Analysis of Organophosphorus Pesticides in Drinking Water

Agilent Consumables Improve Performance with Shimadzu GC/MS

Prefractionator for Reliable Analysis of the Light Ends of Crude Oil and other Petroleum Fractions

Improving GC-MS Method Robustness and Cycle Times Using Capillary Flow Technology and Backflushing

Organohalide Pesticides in Water by GC/µECD with Agilent J&W DB-CLP1 and DB-CLP2

Direct Injection of Fish Oil for the GC-ECD Analysis of PCBs: Results Using a Deans Switch With Backflushing. Application. Author.

A Direct Column-Performance Comparison for Rapid Contract Laboratory Program (CLP) Pesticide Analysis. Application. Authors. Abstract.

Improved Gas Chromatograph Method for the Analysis of Trace Hydrocarbon Impurities in 1, 3-Butadiene

Analysis of Semivolatiles by GC/FID using the Ultra Inert Inlet Liners with Wool

Analysis of Permanent Gases and Extended Hydrocarbons in Natural Gas and Natural Gas Liquids by Capillary Gas Chromatography

GC Troubleshooting. Frank Michel, Katherine K. Stenerson T HCE

Contract Laboratory Program (CLP) Pesticide Analysis with 0.18 mm ID High-Efficiency GC Columns Utilizing Helium Carrier Gas. Application.

Chlorinated Solvents and Disinfection By-Product Analysis Using Agilent J&W HP-1ms Ultra Inert and DB-1301 Capillary GC Columns

Analysis of USP <467> Residual Solvents using the Agilent 7697A Headspace Sampler with the Agilent 7890B Gas Chromatograph

The Use Of Automated Backflush on the 7890A/5975A GC-MS System. Application. Setup Example Using Biomarkers. Authors. Abstract.

Semivolatile Analysis with Specially Designed Agilent J&W DB-UI 8270D Columns

Optimizing Productivity and Reliability for Monocyclic Aromatic Hydrocarbon Purity Analysis According to ASTM D7504 on the Agilent 8890 GC System

High temperature Simdist analysis using the new MXT-1 HT Simdist phase. Jaap de Zeeuw and Gary Stidsen Restek corporation, Bellefonte, PA, USA

Analyze more samples. faster. while maintaining resolution. NEW Agilent J&W High Efficiency Capillary GC Columns

Evaluating Inert Flow Path Components and Entire Flow Path for GC/MS/MS Pesticide Analysis

Fast On-Site Mine Safety Analysis by the Agilent 490 Micro GC

NEW OUTSIDE DIAMETER FUSED SILICA FOR AGILENT J&W CP AND VF GC COLUMNS

Improving GC Resolution and Dealing with Peak Tailing

SCION GC Series. The Gas Chromatographers Choice for Separations

SCION GC Series. The Gas Chromatographers Choice for Separations

Reversed-phase Separation of Intact Monoclonal Antibodies Using Agilent ZORBAX Rapid Resolution High Definition 300SB-C8 1.

3-IN-1 TECHNOLOGY Highest Inertness Lowest Bleed Exceptional Reproducibility

Capillary GC Troubleshooting: a Practical Approach

Agilent Gas Phase Solutions

Reduced carryover and increased reproducibility in the analysis of cold pressed pink grapefruit essential oil

Analysis of Suspected Flavor and Fragrance Allergens in Cosmetics Using the 7890A GC and Capillary Column Backflush Application

The Use of High Resolution Accurate Mass GC/Q-TOF and Chemometrics in the Identification of Environmental Pollutants in Wastewater Effluents

SSENTIALS RESTEK. Must-Have Solutions for Your Lab Leverage 3-in-1 Technology for Outstanding Inertness Low Bleed High Reproducibility

Installation, Care and Maintenance of Capillary Gas Chromatography Columns. Mark Sinnott Application Engineer January 2015 Happy New Year!

Agilent MetaCarb 87H Organic Acids Column H + Form User Manual Part No. A5214

Hydrocarbon Processing Industry Gas Chromatographs. Standard GC Analyzer Solutions

METHOD TRANSLATION OF HJ FOR INTUVO

Accurately Identify and Quantify One Hundred Pesticides in a Single GC Run

Olefin Analyzer Solutions for Polymer Grade Ethylene and Propylene

Gas Chromatography SSI-GC-003

Gas Chromatography Assignment Chem 543/443

Fast Detailed Hydrocarbon Analysis by Modified ASTM Method D6730

A New Horizon of Performance Agilent G1888 Network Headspace Sampler

Rapid UHPLC Analysis of Reduced Monoclonal Antibodies using an Agilent ZORBAX Rapid Resolution High Definition (RRHD) 300SB-C8 Column

Application Note. Abstract. Authors. Environmental

Analysis of Atrazine in Drinking Water at the ppb Level Using New Agilent Reversed Phase LC Columns. Application. Author. Abstract.

Analysis of EPA Method 8270D Semivolatiles Using the Agilent J&W DB-UI 8270D Ultra Inert GC Column

Methods for Increased Sample Throughput with Dirty Samples

Agilent OpenLAB CDS MatchCompare for the Comparison of Peptide Mapping Samples

SCION GC Series. The Gas Chromatographers Choice for Separations

Separation of Recombinant Human Erythropoietin (repo) Using Agilent Bio SEC-3

Faster Separations Using Agilent Weak Cation Exchange Columns

Technical Overview. Author. Abstract. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Improving Your Analysis by Treating Your Flow Path with Agilent s NEW Ultra Inert Technology. Abby Folk GC Technical Support

Fast Analysis of Environmental Phenols with Agilent Poroshell 120 EC-C18 Columns

Pesticide Analysis in a Complex Matrix using a 2D GC/MS System

Improving Productivity in Your Environmental and Food Testing Labs with Agilent 7890A/5975C GC/MS System

Gas Filtration Catalogue

Varian Supplies/Parts. GC Accessories. Septum Nut. Merlin Microseal Kit

Application Note. Biopharma. Authors. Abstract. James Martosella, Phu Duong Agilent Technologies, Inc Centreville Rd Wilmington, DE 19808

TRACE 1300 and TRACE 1310 Gas Chromatographs Dual Detector Microfluidics Installation Guide

The Suite for Environmental GC Analysis

Application Note. Authors. Abstract. Introduction. Pharmaceutical

Optimizing Protein Separations with Agilent Weak Cation-Exchange Columns

The Importance of High Speed Data Acquisition in the Design and Implementation of GC/MS Applications

Determination of Diesel Range Organics (DROs) Using SPE and GC/FID by Method 8015D*

Agilent 6430 Triple Quadrupole LC/MS System

Multiple Detector Approaches to Protein Aggregation by SEC

MARKET FOCUSED - environmental ORGANOCHLORINE PESTICIDES

Ghost Peaks in Gas Chromatography Part 2: The Injection Port

Fast and High-Resolution Reversed-Phase Separation of Synthetic Oligonucleotides

Agilent 490 Micro GC Biogas Analyzers

Automated Real-Time Determination of Bromate in Drinking Water Using LC-ICP-MS and EPA Method Application

PerkinElmer Supplies/Parts. GC Accessories. Autosampler Syringes

Method Translation in Liquid Chromatography

Capillary Flow Technology: Backflush REDUCE RUN TIME AND INCREASE LABORATORY THROUGHPUT

Standard Test Methods for Aromatics in Mineral Spirits by Gas Chromatography 1

Low-level Detection of Ethanol, 1,4-Dioxane, and Other Oxygenates Using the Eclipse Purge-and-Trap Sample Concentrator

Forensic Toxicology. Analysis of Ethanol in Blood using Master SHS Static Headspace Sampler and Master GC Gas Chromatograph APPLICATION NOTE.

Turnkey configurations for gas chromatographic analysis, including instrumentation, methods, supplies and service. Analysis of Natural Gas

Optimization of Volatile Petroleum Hydrocarbons Analysis by Automated Headspace Using Method Development Tools

Mach-RGA. The Fast Refinery Gas Analyzer. Analyzer

CORESTA Recommended Method No. 57

2008 Acid catalyzed esterification of propionic acid with 1-butanol to propionic acid 1-butyl ester

Agilent AdvanceBio SEC Columns for Aggregate Analysis: Instrument Compatibility

Chem 321 Lecture 23 - Liquid Chromatography 11/19/13

Application Note. Author. Abstract. Pharmaceuticals. Detlef Wilhelm ANATOX GmbH & Co. KG. Fuerstenwalde, Germany mau

Productivity and accuracy enhancements

Reproducible LC/MS Peptide Separation Using Agilent AdvanceBio Peptide Plus Columns

Two Headspace Solutions for the Analysis of Dissolved Gases in Water by Method RSKSOP-175

EPA 8330A Analysis of Explosives Using Agilent Poroshell 120 EC-CN and EC-C18 Columns

Energy Saving Capillary Gas Chromatograph

TurboMatrix Headspace and Headspace Trap Samplers

Please enclose a item wise compliance report along with the technical bid.

A method to pack Agilent Prep C18 Media on Load & Lock Column

Separation and Quantitation of a Mixture of Alcohols by Gas Chromatography

Fast Refinery Gas Analysis Using the Agilent 490 Micro GC QUAD

Super Clean Gas Filters Simply the best

Agilent MetaCarb Ca PLUS Carbohydrate Column Ca ++ Form User Manual Part No. A5205

EPA Method 524 for Determination of VOCs in Drinking Water Using Agilent 5975T LTM GC/MSD with Static Headspace

Transcription:

Agilent Ultimate Plus Fused Silica Tubing Technical Overview Introduction Deactivated fused silica tubing is widely used for guard columns, transfer lines, or long retention gaps in GC and GC/MS applications with heavy matrix, and for analysis of semivolatile compounds [1,,3,]. High inertness is a key requirement of tubing for the accurate and reproducible measurement of more reactive compounds at trace levels to minimize analyte degradation and reduce peak tailing. Building on experience in developing deactivation chemistries for capillary tubing, Agilent has released a novel fused silica for GC and GC/MS applications. This Ultimate Plus deactivation technology elevates surface deactivation to a new level. This technical overview describes the testing of the Agilent Ultimate Plus deactivated tubing and compares it to tubing from another supplier, using two procedures: Chromatographic test for inertness, by measuring peak asymmetry and relative recoveries of several compounds Temperature stability and flexibility test for robustness, by assessing the change in color of the polyimide coating of different tubing observed after 7 or 1 hours of thermal exposure to 3 C. In addition, the flexibility of tubing before and after temperature stability testing was also investigated, during which the tubing was destroyed by extreme bending.

Material and Methods Tubing inertness was tested using the tandem-column setup shown in Figure 1. The GC reference column was an Agilent J&W VF-5ms, 3 m.5 mm,.5 µm (p/n CP89). A system test was initially performed to establish the base level inertness profile, in which a piece of reference column was connected to a flame ionization detector (FID) (Figure 1A). Subsequently, the Agilent Ultimate Plus or fused silica tubing from another supplier was replaced to connect to the FID detector (Figure 1B). The inertness of the tubing was evaluated with respect to peak asymmetry and recoveries of compounds in two test mixtures (Test Mix and Very Inert Mix ) [5,], shown in Tables 1 and. The composition of compounds known to adsorb onto active sites of tubing in these test mixtures (for example, 1-decanol, -picoline, trimethyl phosphate, and 1,-pentanediol) were carefully selected, which provided an effective evaluation of tubing inertness performance. A B Inlet Inlet Reference column (VF-5 ms) Reference column (VF-5 ms) Ultimate Union Ultimate Union 1-cm reference column Detector (FID) Agilent/other supplier tubing Detector (FID) Figure 1. The tandem-column setup of system test (A) and Agilent/other supplier tubing test (B). Table 1. Test Mix (.1 mg/ml cyclohexane). Peak no. Compound Amount on column (ng) 1 1-Octanol 1 n-undecane 1 3,-Dimethylphenol 1,-Dimethylaniline 1 5 n-dodecane 1 Naphthalene 1 7 1-Decanol 1 8 n-tridecane (used as 1% reference) 1 9 Decanoic acid ME 1 Table. Very Inert Mix in dichloromethane. Peak no. Compound Amount on column (ng) 1 Methane Propionic acid 1 3 iso-butyric acid 1 n-butyric acid 1 5 Octene.5 Octane.5 7 1-Nitrobutane 1 8 -Picoline 9 Trimethyl phosphate 5 1 1,-Pentanediol 11 Propylbenzene 1 1 1-Heptanol 1 13 3-Octanone 1 1 n-decane (used as 1% reference) 1 Conditions Very Inert Mix Oven: C for min Carrier: Hydrogen, 1.35 ml/min Injector: 5 C, split 1:75, 1 µl Detector: FID at 35 C, ml/min air, 3 ml/min hydrogen, 3 ml/min nitrogen make-up Test Mix Oven: 1 C for min Carrier: Hydrogen, 1.35 ml/min Injector: 5 C, split 1:1, 1 µl Detector: FID at 35 C, ml/min air, 3 ml/min hydrogen, 3 ml/min nitrogen make-up

Results and Discussion Chromatographic test The trial of Test Mix was performed at an oven temperature of 1 C. Figure shows a chromatographic comparison of the system test, with Agilent and another supplier tubing ( m ). No significant difference in performance was evident by visual inspection (Figure ). Peak asymmetry (measured at 1% peak height) and recoveries were used for evaluation of inertness performance between Agilent and other supplier tubing. 1 13 1 11 1 9 pa XOffset: YOffset: 38 1 1.93.1 3.7.8 3.19 5 3. 7.18 8.7 9 5.9 Peak ID 1. 1-Octanol. n-undecane 3.,-Dimethylphenol.,-Dimethylaniline 5. n-dodecane. Naphthalene 7. 1-Decanol 8. n-tridecane 9. Decanoic acid ME 8 7 5.7.89 3. 3.3 3.9 3.83.9 5.5.7 3.7.91 3.5 3. 3.97 3.8.98 5.5.8 1.8 1 1. 1. 1. 1.8....8 3 3. 3. 3. 3.8 RT (min) Figure. Comparison of different types of tubing, m, using Test Mix. Top chromatogram: system test with an Agilent J&W VF-5ms as reference column connected to a 1-cm reference column using an Agilent Ultimate Union (p/n G318-581) and UltiMetal Plus Flexible Metal ferrule (p/n G3188-753). Middle chromatogram: 1-cm reference column replaced by -m Agilent Ultimate Plus deactivated fused silica tubing. Bottom chromatogram: 1-cm reference column replaced by -m deactivated fused silica tubing from another supplier.....8 5 5. 5. 5. 5.8... 3

In Figure 3, peak asymmetry values of a nonpolar compound (n-decane) were similar for Agilent and other supplier tubing. These values were close to 1, which is defined as the asymmetry factor of an ideal peak. However, peak asymmetry factors of a polar compound (1-decanol) using Agilent tubing were closer to 1 than those of other supplier tubing, in a variety of internal diameters. Differences were more significant with larger id tubing. This indicated the improved inertness performance of Agilent tubing compared to tubing from another supplier, explained by interactions between polar compounds and active sites on the surface of deactivated fused silica tubing, which results in an increase in peak asymmetry of these compounds. Better relative recoveries of 1-decanol (compared to n-tridecane) were also found for Agilent tubing (shown in Figure ). 1.8 1. 1. 1. 1.8... System test 1-decanol n-c13 Figure 3. Asymmetry (measured at 1% peak height) of 1-decanol when using Agilent or other supplier deactivated fused silica tubing, compared to system test. Duplicate tubing was tested. 9 8 7 5 % 3 1 System test Figure. Relative recoveries (compared to n-tridecane) of 1-decanol when using Agilent or other supplier deactivated fused silica tubing, compared to system test. Duplicate tubing was tested.

The inertness performance of the Agilent tubing and other supplier tubing was also tested using a Very Inert Mix at an oven temperature of C. The separation results of this test mixture indicated that the Agilent tubing clearly showed significantly improved inertness compared to tubing from another supplier. Trimethyl phosphate, 1,-pentanediol, and n-propylbenzene (compounds 9-11) were separated when using Agilent tubing (middle chromatogram, Figure 5). Conversely, trimethyl phosphate and 1,-pentanediol were strongly adsorbed due to active surface of other supplier tubing. As a result, the peaks were small with heavy tailing, which resulted in apparent coelution with n-propylbenzene (bottom chromatogram, Figure 5). 5 5 8 3 1 pa XOffset: YOffset: 15 1.5.5 5. 3.3 1.97 7 3. 8 3.57 9 5.31 1 5.79 11.3 1 7. 13 8.7 1 8.9 Peak ID 1. Methane. Propionic acid 3. iso-butyric acid. n-butyric acid 5. Octene. Octane 7. 1-Nitrobutane 8. -Picoline 9. Trimethylphosphate 1. 1,-Pentanediol 11. Propylbenzene 1. 1-Heptanol 13. 3-Octanone 1. n-decane 3 8.5 3.53 5 3.3 3. 3.9 7 8..7 9.8 1 7.7 11 7.9 1 13 8. 9.18 1 1. 1 1 8 3.7 5 3.3 3 3..5.95 7.13 8 9-11.7 1 8. 13 9.9 1 9.8 1 1.5.5 3 3.5.5 5 5.5.5 7 7.5 8 8.5 9 9.5 1 1.5 RT (min) Figure 5. Comparison of different types of tubing, m, using Very Inert Mix. Method as for Figure. 11 5

Temperature stability and flexibility test Mechanical stability is one of the most important parameters of tubing and was assessed using a flexibility test. Several examples of Agilent and other supplier tubing were bent to minimum diameters before breakage occurred. Each measurement used 15 cm of tubing. The average value of minimum bend diameter for 1 measurements per tube was calculated. Subsequently, the minimum bend radius was converted into a force value using our empirical formula, which depends on the internal diameter of tubing (shown in Table 3). The higher the force, the stronger the tubing. Figure shows a comparison of strength between Agilent and other supplier tubing at different internal diameters. There was no significant difference in strength between the narrow Agilent and other supplier tubing (id.1 and ). However, Agilent Ultimate Plus tubing showed improved results compared to tubing from another supplier at id. To investigate the influence of long-term thermal exposure on the strength of Agilent tubing, a combined experiment of temperature stability and flexibility was carried out. The strength of several Agilent tubes was measured before and after thermal exposure of 1 hours at 3 C (Figure 7). In general, measurements indicated that there was no significant difference in the strength of Agilent tubing before and after lifetime testing for all internal diameters, except for tubing of id. These results were reasonable, because large internal diameter tubing has larger surface area compared to smaller diameter tubing. Table 3. Calculation of force value from minimum bend radius Internal diameter (mm) Formula <.5 y = 1.1x 1.1.3 y = 13.9x 1.5.53 y = 355x 1.3 where y = force value, x = minimum bend radius Force (Kpsi) 7 5 3 1 Figure. Strength test of Agilent and other supplier tubing at different internal diameters. 7 Before After 5 Force (Kpsi) 3 1 id id id.5 mm id.3 mm id Figure 7. Strength of Agilent tubing before and after lifetime testing for 1 hours exposure at 3 C.

Table. Agilent deactivated fused silica tubing order guide. A variety of inner diameters and lengths are available. Another test of temperature stability was performed for 7 hours exposure at 3 C to compare eight Agilent fused silica deactivated tubes (left) and one other supplier fused silica deactivated tube (right with red arrow), as shown in Figure 8. The color of the external polyimide coating of all the tubing was the same before thermal exposure (top image). However, the color of the external coating of all Agilent tubing was unchanged after long-term thermal exposure (eighth left tube, bottom image). Conversely, the external coating of tubing from another supplier changed to a darker color because of damage to the polyimide coating (one right tube, bottom image). This may lead to brittleness, which can shorten the lifetime of the tubing and make it more difficult to achieve a leak-free seal when using press-fit unions. Part number Description CP81 Fused silica, Ultimate Plus Deactivated, m CP8185 Fused silica, Ultimate Plus Deactivated, 5 m CP818 Fused silica, Ultimate Plus Deactivated, m CP8181 Fused silica, Ultimate Plus Deactivated, 1 m CP855 Fused silica, Ultimate Plus Deactivated,.5 mm 5 m CP851 Fused silica, Ultimate Plus Deactivated,.5 mm 1 m CP853 Fused silica, Ultimate Plus Deactivated,.5 mm 3 m CP835 Fused silica, Ultimate Plus Deactivated,.3 mm 5 m CP831 Fused silica, Ultimate Plus Deactivated,.3 mm 1 m CP833 Fused silica, Ultimate Plus Deactivated,.3 mm 3 m CP8535 Fused silica, Ultimate Plus Deactivated, 5 m CP853 Fused silica, Ultimate Plus Deactivated, m CP8531 Fused silica, Ultimate Plus Deactivated, 1 m CP8533 Fused silica, Ultimate Plus Deactivated, 3 m CP8155 Fused silica, Ultimate Plus Deactivated,.15 mm 5 m CP8151 Fused silica, Ultimate Plus Deactivated,.15 mm 1 m Figure 8. Eight Agilent fused silica tubes (left) and a fused silica tube from another supplier (right) before (top image) and after (bottom image) a temperature stability test at 3 C over 7 hours. 7

Conclusions Agilent Ultimate Plus tubing showed better performance overall for inertness, mechanical strength, and thermal stability when compared to deactivated fused silica tubing from another supplier. The use of Agilent tubing is, therefore, recommended for any GC or GC/MS application where a guard column, retention gap, or GC restrictor is used. Table lists part numbers and product descriptions. References 1. Anon. DuraGuard Columns: GC Columns with Built-In Protection. Application note, Agilent Technologies, Inc. Publication number 5988-715EN ().. Doris Smith, Ken Lynam. Evaluating CLP and EPA Methods for Pesticides in Water Using Agilent J&W DB-CLP1/DB-CLP GC columns. Application note, Agilent Technologies, Inc. Publication number 5991-15EN (1). 3. James D. McCurry. Automated Standard and Sample Preparation for Multiple Gas Chromatographic Analyses of Biodiesel. Application note, Agilent Technologies, Inc. Publication number 599-3781EN (9).. Yamin Wang. Analysis of Sulfur Compounds in Petroleum Gases and Natural Gas. Application note, Agilent Technologies, Inc. Publication number 5991-3EN (1). 5. J. Luong, R. Gras, W. Jennings. J. Sep. Sci. 3, 8 (7).. Anon. Agilent J&W Ultra Inert GC Columns: A New Tool to Battle Challenging Active Analytes. Technical overview, Agilent Technologies, Inc. Publication number 5989-85EN (8). www.agilent.com/chem Agilent shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Information, descriptions, and specifications in this publication are subject to change without notice. Agilent Technologies, Inc., 1 Printed in the USA September 5, 1 5991-51EN