Effect of Column Shortening on the Behavior of Tubular Structures

Similar documents
THE STUDY ON BEHAVIOUR OF OUTRIGGERS FOR TALL BUILDINGS SUBJECTED TO LATERAL LOAD

Lateral Stability Analysis of High Rise Building with the Effect of Outrigger and Belt Truss System

DYNAMICPERFORMANCE ANALYSIS OF OUTRIGGER AND OUTRIGGER WITH BELT TRUSS SYSTEM IN COMPOSITE HIGH RISE BUILDING

A Study on Behavior of Structural Systems for Tall Buildings Subjected To Lateral Loads

EFFECT OF COLUMN LOCATION ON PLAN OF MULTI- STORY BUILDING ON SHEAR LAG PHENOMENON

Optimization of Multistory Building with Multi- Outrigger System and Belts Truss

Comparison of shear lag in structural steel building with framed tube and braced tube

DIAGRID STRUCTURAL SYSTEM: STRATEGIES TO REDUCE LATERAL FORCES ON HIGH-RISE BUILDINGS

International Journal of Scientific & Engineering Research, Volume 7, Issue 6, June ISSN

Behaviour of RCC Multistorey Structure With and Without Infill Walls

Effect of Change in Shear Wall Location with Uniform and Varying Thickness in High Rise Building

Optimum Position of Multi Outrigger Belt Truss in Tall Buildings Subjected to Earthquake and Wind Load

DYNAMIC ANALYSIS OF STEEL TUBE STRUCTURE WITH BRACING SYSTEMS

SSRG International Journal of Civil Engineering ( SSRG IJCE ) Volume 4 Issue 6 June 2017

Seismic Analysis of RC Shear Wall Frame Buildings with and Without Openings in Shear Wall

Optimum Position of Outrigger System for Tall Vertical Irregularity Structures

A Comparative Study on Non-Linear Analysis of Frame with and without Structural Wall System

Earthquake Behavior of RCC Building for Various Shear Wall Configurations

STUDY OF SEISMIC PERFORMANCE OF RC BUILDING WITH FLAT PLATE INFLUENCED BY CONCRETE WALL

Keywords: Discrete Staggered Shear Wall, High-Rise Building, Response Spectrum Analysis, Storey Drift.

IJSRD - International Journal for Scientific Research & Development Vol. 5, Issue 06, 2017 ISSN (online):

Design of Tall RC Buildings: Core Supported Structures and Outrigger Braced Systems

SEISMIC PERFORMANCE OF HIGH-RISE BUILDING

Effect of Mass and Stiffness of Vertically Irregular RC Structure

DESIGN AMPLIFICATION FACTOR FOR OPEN GROUND STOREY RC STRUCTURE WITH INFILL OPENINGS IN UPPER STOREYS

Effects of opening in shear walls of 30- storey building

S. Gandhi *1, Syed Rizwan 2

Comparative Analysis of Moment Resisting Frames of Steel and Composite Materials

Analysis of G+7 Multistoried Building for Various Locations of Shear Wall Considering the Effect of Torsion Using Response Spectrum Method

EFFECT OF CHANGE IN THICKNESSES AND HEIGHTS IN SHEAR WALL ON DEFLECTION, STORY DRIFT AND STIFFNESS OF MULTISTORIED BUILDINGS

Research Paper on Earthquake and Wind Analysis of Braced Tube Structure with Different Plans in Configuration

Seismic Analysis of RC Framed Building for Different Position of Shear wall

Study of P-Delta Effect on Tall Steel Structure

Seismic Behavior of High Rise Building for Soft Soil in All Seismic Zones Shaik Fayaz 1 Mrs. B.Ajitha 2

Comparative Study of Flat Slab and Conventional Slab Structure Using ETABS

Comparative Study on Analysis and Cost of R.C.C. and Steel-Composite Structure

ANALYTICAL STUDY ON SEISMIC RESPONSE WITH AND WITHOUT SOFT STOREYS IN MULTISTOREY RC BUILDING

Parametric Study on Asymmetric Diagrid Structures

PARAMETRIC STUDY ON VERTICAL IRREGULAR HIGH RISE REINFORCED CONCRETE FRAMED BUILDING

International Journal of Scientific & Engineering Research, Volume 5, Issue 5, May ISSN

EFFECT OF DIFFERENT POSITION OF SHEAR WALL ON DEFLECTION IN HIGH RISE BUILDING

EFFECT OF DIFFERENT SHEAR WALL CONFIGURATIONS ON SEISMIC RESPONSE OF A MOMENT-RESISTING FRAME

International Journal of Scientific & Engineering Research, Volume 7, Issue 5, May ISSN

Analysis of Reinforced Concrete Building With Different Plan Shapes Resting on Sloping Ground

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 05, 2016 ISSN (online):

TO STUDY THE PERFORMANCE OF HIGH-RISE BUILDING UNDER LATERAL LOAD WITH BARE FRAME AND SHEAR WALL WITH OPENINGS

Seismic Performance Of R C Flat-Slab Building Structural Systems

ANALYSIS AND EVALUATION OF STRUCTURAL SYSTEMS WITH BRACING AND SHEAR WALL

SEISMIC BEHAVIOR OF MULTI-STORY STRUCTURE WITH DIFFERENT TYPES OF SLABS

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 2, No 2, 2011

A Study on Seismic Analysis of High Rise Irregular Floor Plan Building with Different Position of Shear Walls

Study of Strength of RC Shear Wall at Different Location on Multi-Storied Residential Building

Effect of Infill Walls on Structural Frames

Influence of Concrete and Steel outrigger and belt truss in high rise Moment Resisting Frames

Analysis of High Rise Building with Outrigger Structural System

SEISMIC ANALYSIS OF HIGH RISE BUILDINGS WITH PLAN IRREGULARITY

A Study of Efficient Outrigger Structural Systems for Tall Buildings

MULTI-STOREY BUILDINGS - II

Geometrically Variations of Steel Frame Structures: P-Delta Analysis

Analytical Study on Seismic Performance of Hybrid (DUAL) Structural System Subjected To Earthquake

DYNAMIC RESPONSE OF MULTISTORIED BUILDING WITH AND WITHOUT IN-FILL WALLS

IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 07, 2014 ISSN (online):

Comparative Study of Irregular-shaped RC Building with Different Lateral Load Resisting Systems

Seismic Analysis of a Multi-Storeyed Building with Irregular Plan Configuration Using ETABS N. Mohan Reddy 1 Dr. E. Arunakanthi 2

Evaluation of Response Reduction Factor and Ductility Factor of RC Braced Frame

ANALYTICAL INVESTIGATION ON THE PERFORMANCE OF TUBE-IN-TUBE STRUCTURES SUBJECTED TO LATERAL LOADS

EFFECTS OF SOIL CONDITION ON BEHAVIOR OF STIFFENED RC FRAME STRUCTURES SUBJECTED TO EARTHQUAKES

AN ANALYTICAL STUDY ON OUTRIGGER STRUCTURES USING NON LINEAR DYNAMIC TIME HISTORY ANALYSIS

[Gajbe* et al., 5(7): July, 2016] ISSN: IC Value: 3.00 Impact Factor: 4.116

EFFECTS OF P-DELTA ON HIGH RISE BUILDINGS LOCATED IN SEISMIC ZONES

SEISMIC BEHAVIOUR OF RC BUILDING RESTING ON PLAIN AND SLOPING GROUND WITH BRACINGS AND SHEAR WALL

A Performance Based Evaluation of a Wall- Frame Structure Employing the Pushover Analysis Tool

Earthquake Resistant Design for Low Rise Open Ground Storey Famed Building

SEISMIC RESPONSE OF A MID RISE RCC BUILDING WITH SOFT STOREY AT GROUND FLOOR

Analysis of Flat Slab and Waffle Slab in Multistorey Buildings using ETABS

Effects Of Vertical Geometric And Mass Irregularities In Structure

OPTIMAL DIAGRID ANGLE TO MINIMIZE DRIFT IN HIGH-RISE STEEL BUILDINGS SUBJECTED TO WIND LOADS

International Journal of Scientific & Engineering Research, Volume 7, Issue 10, October ISSN

Behaviour of Tall Structure with Eccentric Loading

Effect of Edge Beam and Shear Wall on the Structural Behavior of Flat Plate Multistoried Building: A Computing Modeling for lateral load Analysis

SEISMIC PERFORMANCE OF HIGH RISE FLAT SLAB BUILDING WITH VARIOUS LATERAL LOAD RESISTING SYSTEMS

International Journal of Advance Engineering and Research Development

STUDIES ON LOCATION OF SHEAR WALL IN BUILDINGS FOR STRUCTURAL STABILITY

EARTHQUAKE ANALYSIS OF A G+12 STOREY BUILDING WITH AND WITHOUT INFILL FOR BHUJ AND KOYNA EARTHQUAKE FUNCTIONS

A Review on Comparison of Seismic Behavior of RC Structures Using Various Codes

Study of Shear Walls in Different Locations of Multistoried Building with Uniform Thickness in Seismic Zone III

International Journal of Intellectual Advancements and Research in Engineering Computations

Literature survey on Analysis of Multistory Building considering Hybrid Structure

Analysis of Effects of Axial Shortening of Steel Columns in Frame Structure

STRESS ANALYSIS OF R.C.C. DESIGNED SHEAR WALL IN A BUILDING FRAME SUBJECTED TO WIND LOADS

SEISMIC ANALYSIS OF SIX STOREYED RC FRAMED BUILDING WITH BRACING SYSTEMS

SEISMIC ANALYSIS OF SIX STOREYED RC FRAMED BUILDING WITH BRACING SYSTEMS

Significance of Shear Wall in Multi-Storey Structure With Seismic Analysis

International Journal of Engineering and Techniques - Volume 4 Issue 2, Mar Apr 2018

Comparative Analysis of T-shaped RC frame Structures with and without Shear Wall as per IS and IS

Dynamic analysis of RC frame braced tube structure

STUDY OF IRREGULAR RC FRAME BUILDINGS UNDER SEISMIC

SIGNIFICANCE OF SHEAR WALL IN FLAT SLAB MULTI STORIED BUILDING - A REVIEW. Vavanoor, India

Parametric Study of Dual Structural System using NLTH Analysis Ismaeel Mohammed 1 S. M. Hashmi 2

Investigation for Base Shear and Roof Displacement for Multi-Storey Building with Different Location of Shear Wall Using STAAD Pro

Transcription:

Indian Journal of Science and Technology, Vol 8(36), DOI: 1.17485/ijst/215/v8i36/87533, December 215 ISSN (Print) : 974-6846 ISSN (Online) : 974-5645 Effect of Column Shortening on the Behavior of Tubular Structures J. S. Arvind * and M. Helen Santhi SMBS, VIT University Chennai Campus, Chennai - 6127, Tamil Nadu, India; arvind.js214@vit.ac.in, helensanthi.m@vit.ac.in Abstract This paper presents the column shortening effect on the behavior of Tubular, Tube in tube and Bundled tube structure. Frame tube buildings consist of closely spaced column connected by deep spandrel beams placed on the perimeter in plan. A Tube in tube and Bundled tube structure of 5 storeys with storey height of 4 m is considered for the study, RC columns and spandrel beams are modelled with M7 and M11 concrete mix. Models are developed using ETABS software and the effect of elastic shortening of the RC column is included in the analysis to study the behavior by calculating member forces. From the analysis, the effects due to elastic shortening in parameters such as axial force, shear force, bending moment and time period are obtained and compared between the tubular, tube in tube structure and bundled tube structure, there is a variation of about 25%, 2%, 23% and 74% and 23%, 17%, 25% and 57%. 19%, 15%, 31% and 6% respectively, which results in the reduction of member size, which ultimately reduces the dead load and the cost of construction. Keywords: Bundled Tube Structure, Elastic Column Shortening, Tube in Tube Tall Structure, Tubular Structure 1. Introduction The vertical city concept has been manifested due to increase in population density and demand on cultivation land. The advancement of technology and the development of economy of the world have made the vertical city concept dream become true in the way of tall buildings/ towers. Fazlur Khan of Bangladesh has introduced the tall buildings concept and he had addressed many structural systems for the high-rise buildings. Some of the structural systems adopted for tall buildings are wall-frame structure, framed tube structures, outrigger-braced structures, suspended structures, core structures, space structures and hybrid structures for lateral loads supports 1. The framed-tube of many type have being developed for lateral load resisting systems. Some of them are multiple tube systems, Bundled tube systems and tube-in-tube systems 2,3. The Tube in tube and Bundled tube structure is being taken for the current study. A typical form of framed tube structure is shown in Figure 1. Taranath et al. tubular system structure is a structure with closed column space between two to four meters and jointed by a deep spandrel beams at the floor level as shown in Figure 2. A group of columns perpendicular to the direction of the horizontal load is called flanged frame and a group of columns parallel to the direction of the horizontal load is called web frames 4. Since the columns are closed to each other and the spandrel beams are deep, the structure can be considered as perforated tube and behaves as a cantilever tube. The flanged frame columns will resist the axial forces (tension and compression) and the web columns will resist the shear forces 4. Coull et al. it has been proved that the tubular structure is an efficient structural system to resist the horizontal loads. However, in the actual tubular structure, the distribution of axial forces along the flanged frame columns at one floor is not uniform and the distribution of shear forces along the web is not linear. This is mainly due to the flexibility of the structure. This phenomenon *Author for correspondence

Sipil F.T. Untar/No.2 TahunKe III; 1997. p. 73 85. K. Deflection of framed tube structures. Journal of the roceedings of The American Society of Civil Engineers; 1978 5 61. Effect of Column Shortening on the Behavior of Tubular Structures ook on wind and earthquake resistant buildings: Structural ew York: Marcel Dekker; 24. suited for story height from 4-1. Thus considering 8 uan H. Simple analysis of framed-tube structures with multiple the ructural Design of Tall and Special Buildings. 21; 8: :97 13. shear lag effect and the seismic effect on the buildings, the models for this study are square in plan. Table 1 shows the details of tabular structure under study. In this analysis of Tube in tube structure, the inner tube is Figur assumed re 1. A to typica be of al form closely of fra spaced amed tube column. structure. The connection Comp of ponents secondary in tall beams structure. to the core columns is hinged connection and the connection of spandrel beams to columns is rigid connection. The floor plan of tubular structure is shown in Figure 3 and Tube in tube structure Table 1. Details of Structure is shown in Figure 4. In the case of Bundled tube structure, the closely spaced core columns are placed on Spandrel the four corners of the Number building as Concrete shown e in the Column Figure 5. beam Figure 1. A typical form of framed tube structure. of Storey Mix size (m) size (m) Table 1. Number of Storey Figure 1. A typical form of framed tube structure. Components in tall structure. 8 Details of Structure 5 M7 Concrete Mix Column Spandrel Spacing of Storey size (m) beam size (m) columns (m) height (m) 5 M7 1. 1..5.5 2. 4 5 M1 Figure 2. 1.x1. 1.x1. 5 M1 1. 1..5.5 2. 4.5 x.5.5 x.5 Spac colu (m) 2. 2. Table 1. Details of Structure Figure 2. Components in tall structure. Spandrel Spacing of Number Concrete Column Storey beam columns of Storey Mix size (m) height (m) reduces the efficiency of the tubular structures and it is size (m) (m) called shear lag effect. The efficiency of the tubular structure is measured by the shear 5lag factor. M7 The shear lag 1.x1. 2. 4.5 x factor can be defined as the ratio of the stress at the centre.5 of the flanged and the stress at the corner of the flange 5..5 x Mola et al. observed that 5 the tubular M1 structure was 1.x1. 2. 4 efficient if the shear lag factor of.7 is achieved. In the Figure.53. Floor plan of tubular structure figure design of tall buildings the challenge for the engineer is to maximize the shear lag factor with minimum weight. When the shear lag is equal to one, the axial forces are Figure 3. Floor plan of tubular structure figure, plan of tube in tube structure. distributed equally along the flange. In tubular structural system, there are several parameters contribute to the shear lag factors, among them all the size of the spandrel beams and columns along the flange, the bending stiffness of the web and the shape of the structures 6. 2. Modelling of Tubular Structure Structure consists of closely spaced column connected by deep spandrel beams placed on the perimeter in plan. Tubular, Tube in tube and Bundled buildings are generally Figure 4. Floor plan of tube in tube structure. 2 Vol 8 (36) December 215 www.indjst.org Figure 3. Floor plan of tubular structure figure, plan of tube in tube structure. Figure 4. Floor Indian Journal of Science and Technology

J. S. Arvind and M. Helen Santhi Figure 5. Floor plan of Bundled tube structure. 3. Analysis of Framed Tubular Frames The 3D analysis of the structure is carried out using the ETABS software which is based on the stiffness approach. The calculations made are mentioned below: 3.1 Load Patterns Dead load is calculated by taking the self weight of each members. Imposed load is taken to be as 3 kn/m 2 and wind load is calculated as per IS 875 part-3 7. 3.2. Wind Load Wind load is calculated as per IS 875 Part- 3 7 where the location is considered as Chennai and the following parameters are calculated. The calculated wind pressure is distributed based on the height of floor and number of columns in that floor: Design wind speed (V z ) = 7 m/s Design Wind Pressure (P z ) = 2597 N/m 2 3.4 Elastic Shortening of RC Columns A column in a tall building undergoes axial shortening considerably more than its lower brethren required that special attention be paid in column design 8. A related problem, by no means unique to tall buildings, but one that gets aggravated to a great extent, is the levelness of floors 9,1. Similarly, the problem of human response to transient vibration of floors is not unique to tall buildings but needs careful study because the cost of correcting the problem in a tall building with several floors is phenomenally more expensive than correcting the relatively fewer floors of a low-rise building. Column in tall building subjected to larger axial displacement due to the accumulated load from a large number of floors and also from the larger length is known as axial elastic shortening 11. It depends on material properties of columns and the stress induced strains due to axial load 11,12. 4. Results and Discussion The models for this study are square in plan having 5 storeys. The parameters like axial force, shear force, bending moment and time period is considered and compared and the variation in these parameters due to column shortening is discussed below. The change in axial force due to column shortening in Tubular, Tube in tube and Bundled tube structure are shown in Figure 6. The column shortening effect in structure with M7, M11 grades and structure without column shortening is compared. The result shows a variation of about 2%, 23% and 19% decrease in the axial force in the Tubular, Tube in tube and Bundled tube structure respectively with column shortening to the structure without column shortening. 25 3.3 Analysis The analysis is performed using ETABS. The analysis is performed with elastic shortening when the properties of the columns and beams are modelled and load is applied. 1 5 The member properties like area and moment of inertia of columns and moment of inertia of spandrel beams WITH WITH WITH OUT are given as explicit input then analysis is performed (M7) (M11) for obtaining column and beam forces without effect of elastic shortening of the RC columns. Figure 6. Comparison of Max Axial force. Max Axial Force (kn) 2 15 IN Vol 8 (36) December 215 www.indjst.org Indian Journal of Science and Technology 3

Effect of Column Shortening on the Behavior of Tubular Structures The change in shear force due to column shortening in Tubular, Tube in tube and Bundled tube structure are shown in Figure 7. The column shortening effect in Tube in tube and Bundled tube structure with M7, M11 grades and structure without column shortening is compared. The result shows a variation of about 23%, 17% and 15% decrease in the shear force in the Tubular, Tube in tube and Bundled tube structure respectively with column shortening to the structure without column shortening. The change in bending moment due to column shortening in Tube in tube and Bundled tube structure are shown in Figure 8. The column shortening effect in Tube in tube and Bundled tube structure with M7, M11 grades and structure without column shortening is compared. The result shows a variation of about 24%, 27% and 31% decrease in the bending moment in the Tube in tube and Bundled tube structure respectively with column shortening to the structure without column shortening. Max Shear Force (kn) 3 25 2 15 1 5 WITH WITH (M7) (M11) WITH OUT IN The change in time period due to column shortening in Tubular, Tube in tube and Bundled tube structure with column shortening with M7, M11 and without column shortening are shown in Figures 9, 1 and 11 respectively. The column shortening effect in Tube in tube and Bundled tube structure with M7, M11 grades and structure without column shortening is compared. The result shows a variation of about 62%, 57% and 6% increase in the time period of the Tubular, Tube in tube and Bundled tube structure respectively with column shortening to the structure without column shortening. The change in Storey drift in Tubular, Tube in tube and Bundled tube structure with column shortening and without column shortening is shown in Figures 12, 13 and 14 respectively and the result shows a variation Time Period (Sec) 5 4.5 4 3.5 3 2.5 2 1.5 1.5 IN 1 2 3 4 5 6 7 8 9 1 11 12 Mode Figure 9. Comparison of time period. With Column shortening (M7). Figure 7. Max Bending Moment (kn m) Figure 8. Comparison of Max Shear force. 7 6 5 4 3 2 1 WITH (M7) WITH (M11) WITH OUT IN Comparison of Max bending moment. Time Period (Sec) 4.5 4 3.5 3 2.5 2 1.5 1.5 IN 1 2 3 4 5 6 7 8 9 1 11 12 Mode Figure 1. Comparison of time period. With Column shortening (M11). 4 Vol 8 (36) December 215 www.indjst.org Indian Journal of Science and Technology

J. S. Arvind and M. Helen Santhi 2 5 Time Period (Sec) 1.5 1.5 IN STOREY LEVEL 4 3 2 1 WITH WITHOUT 1 2 3 4 5 6 7 8 9 1 11 12 Mode Figure 11. Comparison of time period - without column shortening. 1 2 3 DRIFT (mm) Figure 14. Comparison of storey drift in Bundled tube structure with and without column shortening effect. STOREY LEVEL 5 4 3 2 1 2 4 6 DRIFT mm) STRUCTURE WITH STRUCTURE WITHOUT Figure 12. Comparison of storey drift in tubular structure with and without column shortening effect. STOREY LEVEL 5 4 3 2 1 1 2 3 4 5 DRIFT (mm) TUNULAR STRUCTURE IN STRUCTURE STRUCTURE Figure 15. comparison of storey drift in Tubular, Tube in tube and Bundled tube structure with column shortening effect. STOREY LEVEL 5 4 3 2 1 1 2 3 4 DRIFT (mm) IN WITH IN WITHOUT Figure 13. Comparison of storey drift in Tube in tube structure with and without column shortening effect. of about 74%, 7% and 6% decrease in Tubular, Tube in tube and Bundled tube structure with column shortening and without column shortening. The change in Storey drift in Tubular, Tube in tube and Bundled tube structure with column shortening is shown in Figure 15. 5. Conclusion The columns in a tall building undergoes axial shortening considerably more than columns in the low and medium rise buildings. This leads to the uneven settlement of the floor levels. In this paper, the Tubular, Tube in tube and Bundled tube structure are analysed and the following conclusions are drawn: Decrease in the maximum bending moments, Axial force, Shear Force of about 25%, 2% and 23% respectively while comparing the Tubular structure without column shortening to the structure with column shortening. Decrease in the maximum bending moments, Axial force, Shear Force of about 23%, 17% and 25% respectively while comparing the Tube in tube structure without column shortening to the structure with column shortening. Vol 8 (36) December 215 www.indjst.org Indian Journal of Science and Technology 5

Effect of Column Shortening on the Behavior of Tubular Structures Decrease in the maximum bending moments, Axial force, Shear Force of about 19%, 15% and 31% respectively while comparing the Bundled tube structure without column shortening to the structure with column shortening. Increase in the time period of about 62%, 57% and 6% while comparing the Tubular, Tube in tube structure and Bundled tube structure without column shortening to the structure with column shortening. Decreases in Storey Drift of about 74%, 7% and 6% in the Tubular, Tube in tube structure and the Bundled tube structure without column shortening to the structure with column shortening. Due to reduction of forces the dimension of the structural elements can be reduced which directly reduces the dead load of the structure and also the cost of construction. 6. References 1. Khan FR, Amin NR. Analysis and design of framed tube structure for all tall buildings. ACI Publications SP-36: Response of multistorey concrete structures to lateral forces. 1973; 51(3):39 6. 2. Fintal M, Ghosh SK, Iyengar H. Column shortening in tall structures: Prediction and compensation. Illinois, Chicago: Portland Cement Associations; 1987 Jun. 3. Urs A. Stability analysis of frame tube tall buildings. [Thesis of Master of Science]. Department of Civil Engineering, Worcester Institute; 22 Oct. 4. Taranath BS. Text book on reinforced concrete design of tall buildings. New York: CRC Press, Taylor and Francis Group; 21. 5. Coull A, Subedi NK. Framed-tube structure for high rise buildings. Journal of the Structural Division. Proceedings of the American Society of Civil Engineers. Proc Paper 11696; 1975 Nov. 11(ST11). p. 2223 4. 6. Mola F, Pellegrini LM. Effects of column shortening in Tall R.C Buildings. 35th Conferences on our world in concrete and structure; Singapore. 21 Aug 25-27. p. 1 15. 7. Code of practice for design loads (Other than earthquake) for building and structures. New Delhi: Bureau of Indian Standards; IS 875 (Part 3) 1987. 8. Smith BS, Coull A. Text book on tall building structures: Analysis and design. A Wiley Interscience Publication. New York; John Wiley and Sons; 1st ed. 1991. 9. Soegiarso R, Tjendera E. Behavior of high-rise Tubular structures due to horizontal loads. Journal Teknik Sipil F.T. Untar/No.2 TahunKe III; 1997. p. 73 85. 1. Coull A, Ahemed AK. Deflection of framed tube structures. Journal of the Structural Division. Proceedings of The American Society of Civil Engineers; 1978 May. 14(ST5). p. 875 61. 11. Taranath BS. Text book on wind and earthquake resistant buildings: Structural analysis and design. New York: Marcel Dekker; 24. 12. Lee KK, Loo YC, Guan H. Simple analysis of framed-tube structures with multiple internal tubes. The Structural Design of Tall and Special Buildings. 21; 8:97 13. 6 Vol 8 (36) December 215 www.indjst.org Indian Journal of Science and Technology