Seismic Performance of Base Isolated MultiStorey Building. Mital Desai1, Prof. Roshni John2

Similar documents
SEISMIC ANALYSIS OF SYMMETRIC BUILDING WITH BASE ISOLATION TECHNIQUE

Assistant Professor, Applied Mechanics Department, Government College of Engineering, Amravati, India 2

Study on the Effect of LRB Isolators on Different Asymmetric Plans of RC Structure

Study Response of Fixed Base and Isolation Base

SSRG International Journal of Civil Engineering ( SSRG IJCE ) Volume 4 Issue 6 June 2017

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume X, No X, 2010

Nonlinear Dynamic Analysis of Base Isolated Reinforced Concrete Building

Lucknow,Uttar Pradesh, India. Lucknow,Uttar Pradesh, India

Dynamic Behavior of RC Framed Irregular Building Using Lead Rubber Bearing

Seismic Response of Multi-Storey Building with Elastomeric Lead Rubber Bearing

BASE ISOLATION OF MASS IRREGULAR RC MULTI-STOREY BUILDING

EFFECT OF SOFT STOREY LEVEL VARIATION ON TORSIONAL ROTATION OF LEAD RUBBER BASE ISOLATED STRUCTURE

Effect of Base Isolation in Multi-Storeyed RC Building

STUDY ON LAMINATED RUBBER BEARING BASE ISOLATORS FOR SEISMIC PROTECTION OF STRUCTURES

S. Gandhi *1, Syed Rizwan 2

COMPARATIVE STUDY OF EFFECT OF INFILL WALLS ON FIXED BASE AND BASE ISOLATED REINFORCED CONCRETE STRUCTURES

Analysis of steel braced symmetrical RCC building with designed I-sectional rubber base isolator

Result Analysis of Multistorey Building by Using Response Spectrum Method for Floating Column

Seismic Base Isolation of RC Frame Structures With and Without Infill

Vibration Control of Framed Structure Using Tuned Mass Damper

Effect of Building Height on Torsional Response of Lead Rubber Bearing Base Isolated Structures-A Study

Base Isolation In Seismic Structural Design

Analysis of G+7 Multistoried Building for Various Locations of Shear Wall Considering the Effect of Torsion Using Response Spectrum Method

Seismic Analysis of Multistoried Building

SEISMIC ANALYSIS OF SIX STOREYED RC FRAMED BUILDING WITH BRACING SYSTEMS

SEISMIC ANALYSIS OF SIX STOREYED RC FRAMED BUILDING WITH BRACING SYSTEMS

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 08, 2016 ISSN (online):

Vibration control of a building model with base isolation

Effect of Mass and Stiffness of Vertically Irregular RC Structure

Seismic Behavior of Soft First Storey

Effect of Openings in Shear Wall

COMPARITIVE STUDY OF BASE ISOLATORS AND VISCOUS FLUID DAMPERS ON SEISMIC RESPONSE OF RC STRUCTURES

Seismic Performance of Combined Isolation System for Asymmetric Buildings Using Non- Linear Time History Analysis

Seismic Analysis of Fixed Based and Base Isolated Building Structures

SEISMIC ANALYSIS OF HIGH RISE BUILDING WITH IS CODE and IS CODE

International Journal of Advance Engineering and Research Development SEISMIC ANALYSIS ON BUILDING WITH HORIZONTAL AND VERTICAL IRREGULARITIES

Pushover Analysis Of RCC Building With Soft Storey At Different Levels.

Analysis of a Multi-Tower Frame Structure connected at different levels using ETABS

Seismic analysis of vertically geometric irregular structures

Seismic Vibration Control of Building with Lead Rubber Bearing Isolator

Effect of Soft Storey on Structural Response of High Rise Building

"Comparative study on conventional beam slab and flat slab under various seismic zones and soil conditions

Sensitivity Analysis of LRB Isolator for RC Shear Frame

SEISMIC ANALYSIS OF MULTISTOREYED RC BUILDING DUE TO MASS IRREGULARITY BY TIME HISTORY ANALYSIS

EARTHQUAKE ANALYSIS OF A G+12 STOREY BUILDING WITH AND WITHOUT INFILL FOR BHUJ AND KOYNA EARTHQUAKE FUNCTIONS

Torsional and Seismic Behavior of Shear Wall Dominant Flat Plate Buildings

Dynamic analysis of RC frame braced tube structure

COMPARATIVE ANALYSIS OF A MULTISTORY BUILDING BY RESPONSE SPECTRUM METHOD AND SEISMIC COEFFICIENT METHOD

A Study on Seismic Analysis of High Rise Irregular Floor Plan Building with Different Position of Shear Walls

Seismic Analysis of Buildings with Shear Wall having Horizontal Irregularity

Comparative Study on Seismic Behaviour of Multi Storey Building with and Without Floating Column

Seismic Analysis of Structure by Introducing Weak Story on Top as Tuned Mass Damper

Comparative Study of Equivalent Static Analysis and Response spectrum analysis on Flat Slab Using Etabs

STUDY ON SHAKING TABLE TESTS OF ISOLATED BRIDGE MODEL WITH LRB

Approximate Seismic Analysis Procedure for Multibay RC Framed Structures

DYNAMIC ANALYSIS OF MULTI-STOREY BUILDING

SEISMIC BEHAVIOR OF MULTI-STORY STRUCTURE WITH DIFFERENT TYPES OF SLABS

PARAMETRIC STUDY ON VERTICAL IRREGULAR HIGH RISE REINFORCED CONCRETE FRAMED BUILDING

Comparative Study of Multi-Storey RC Building Having Flat Slab with and without Shear Wall with Conventional Frame Structure Subjected To Earthquake.

Analysis of G+12 Structures with different material of Shear wall using SAP2000

ANALYSIS AND EVALUATION OF STRUCTURAL SYSTEMS WITH BRACING AND SHEAR WALL

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

PUSHOVER ANALYSIS (NON-LINEAR STATIC ANALYSIS) OF RC BUILDINGS USING SAP SOFTWARE

Comparative Study of Floating and Non Floating Column of Plaza Building Subjected to Seismic Loading by Using Staad-Pro Software

IJSRD - International Journal for Scientific Research & Development Vol. 5, Issue 06, 2017 ISSN (online):

Seismic Performance Of R C Flat-Slab Building Structural Systems

Pushover Analysis of Structures with Plan Irregularity

BEHAVIOUR OF RCC FLAT SLAB STRUCTURE UNDER EARTHQUAKE LOADING

Combined Core Pillar Concept for Earthquake Resistant Building

Seismic Analysis of Steel Frames with Different Bracings using ETSBS Software.

Seismic Analysis of a Reinforced Concrete Building by Response Spectrum Method

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 2, No 2, 2011

TO STUDY THE PERFORMANCE OF HIGH-RISE BUILDING UNDER LATERAL LOAD WITH BARE FRAME AND SHEAR WALL WITH OPENINGS

Seismic Performance of Multistorey Building with Soft Storey at Different Level with RC Shear Wall

Seismic Response of RC Framed Structures Having Plan and Vertical Irregularities with and Without Masonry Infill Action

SEISMIC DESIGN OF STRUCTURE

Seismic Analysis of Flat Slab Structure

A Study on Positioning of Different Shapes of Shear Walls in L Shaped Building Subjected to Seismic Forces

STUDY OF SEISMIC PERFORMANCE OF RC BUILDING WITH FLAT PLATE INFLUENCED BY CONCRETE WALL

International Journal of Engineering Research & Science (IJOER) ISSN: [ ] [Vol-3, Issue-3, March- 2017]

Seismic Behaviour Of Flat Slab Framed Structure With And Without Masonry Infill Wall

Seismic Analysis and Design of Regular and Irregular Framed Commercial Buildings

seismic analysis of multistoried rcc building due to mass irregularity

Effect of RC Shear Wall on Seismic Performance of Building Resting on Sloping Ground

Department of Civil Engineering, SKP Engg. College, Tiruvanamalai, TN, India

Comparative Study of Flat Slab Building with and Without Shear Wall to earthquake Performance

SEISMIC ASSESEMENT OF RC FRAME BUILDINGS WITH BRICK MASONRY INFILLS

A Comparative Study of Seismic Response of Flat Slab Structure and Conventional RC Framed Structure

Seismic Analysis of Irregular Shape Building

Comparison of Two Similar Buildings with and without Base Isolation

EFFECT OF SHAPE IRREGULARITY ON FLAT SLAB INDUSTRIAL BUILDING UNDER LATERAL LOADING

Analysis of Flat Slab and Waffle Slab in Multistorey Buildings using ETABS

International Journal of Advance Engineering and Research Development. Comparative study for Seismic Analysis of building using different software

SEISMIC EVALUATION OF RC MULTISTOREY BUILDING OF ASYMMETRIC PLAN WITH VISCO-ELASTIC DAMPER

EARTHQUAKE BEHAVIOR OF BUILDING USING STAAD PRO

Analysis and Design of an Earthquake Resistant Structure using STADD. Pro

STUDIES ON LOCATION OF SHEAR WALL IN BUILDINGS FOR STRUCTURAL STABILITY

THE INTERNATIONAL JOURNAL OF SCIENCE & TECHNOLEDGE

BEHAVIOURAL STUDY OF STIFFNESS IN SOFT STOREY BUILDINGS WITH DIFFERENT INFILLS

Comparison between RCC and Encased Composite Column Elevated Water Tank

Transcription:

International Journal of Scientific & Engineering Research, Volume, Issue, December- ISSN - Seismic Performance of Base Isolated MultiStorey Building Mital Desai, Prof. Roshni John P. G. student, Civil Engineering Department, Saraswati College of Engineering, Maharashtra, India mehtamital@rediffmail.com H.O.D., Civil Engineering Department, Saraswati College of Engineering, Maharashtra, India roshnijjohn@gmail.com plates built in alternate layers as shown in Figure. Horizontal stiffness of the bearing is controlled by the low shear modulus of elastomer while steel plates provides high vertical stiffness as well as prevent bulging of rubber. High damping rubber bearing provides damping in the range of % to %. Abstract: During the last two decades considerable advances have been accomplished in the area of seismic protection of structures. These systems also known as earthquakeprotection system consisting of passive, active, semi-active or hybrid devices and can considerably minimize the seismic effects on structures. The horizontal decoupling of the structure achieved through insertion of bearings at foundation level, transfers it in to lower frequency range and dissipates the energy through damping, the technique is known as isolation. The paper presents comparative study of performance of three types of isolators namely High Damping Rubber bearing (), Low Damping Rubber bearing() and Lead Rubber Bearing ().A -storey building has been analysed using Response Spectrum Method. Dynamic analysis has been done using STAAD Pro software. Parameters like Base shear, Building displacement, frequency, storey drift and spectral acceleration are compared for isolated building and non isolated building. Keywords: Base isolation, damping, energy dissipation, response spectrum, stiffness. Introduction: Fig. Typical High Damping Rubber Bearing Low Damping Rubber Bearing: Rubber bearings have two steel endplates and many thin steel shims interbedded with the rubber. The steel shims can provide the capability of the vertical stiffness but have no effect on the horizontal stiffness, which is dominated by the shear modulus of elastomer. The material in shear is quite linear up to shear strains above % with damping in the range of -%. Using this device, it is also possible to manufacture isolators with no damping, which means that the isolators have exactly linear shear behavior. The isolation technique is a seismic design approach in which, due to the insertion of a flexible layer between the foundation and the superstructure, the fundamental frequency of the system decreases to a value lower than the predominant energy containing frequencies of earthquake ground motion. In addition, the damping capacities provided by the isolation systems help dissipate the energy imparted during seismic activities. Seismic isolation, which is now recognized as a mature and efficient technology, can be adopted to improve the seismic performance of strategically important building such as schools, hospitals, industrial structures, multi-storey buildings etc. In order to minimize inter storey drifts, in addition to reducing floor accelerations; the concept of isolation is increasingly being adopted. Base isolation (BI) has also been referred to as passive control. Lead rubber bearing: A lead-rubber bearing is formed of a lead plug force-fitted into a pre-formed hole in an elastomeric bearing. The lead core provides rigidity under service loads and energy dissipation under high lateral loads. When subjected to low lateral loads such as minor earthquake the lead-rubber bearing is stiff both laterally and vertically. The lateral stiffness results from the high elastic stiffness of the lead plug and the vertical rigidity. A major advantage of the lead-rubber bearing is that it combines the functions of rigidity at service load levels, High Damping Rubber Bearing: is one type of elastomeric bearing. This type of bearing consist of thin layers of high damping rubber and steel

International Journal of Scientific & Engineering Research, Volume, Issue, December- ISSN - is KN. The weight of structure is. KN. The maximum relative displacement is mm. flexibility at earthquake load levels and damping into a single compact unit. TABLE I - DETAILS OF BEARING Sr. No. Dimensions of Bearing Diameter of Bearing Thickness of individual rubber layer Numbers of rubber layer Thickness of individual steel plates Numbers of steel plates Thickness of top and bottom steel plates Total height of bearing Diameter of lead core mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm - - mm Fig. Typical Lead Rubber Bearing Modeling of a structure: Table I shows dimensions of bearing which are calculated on the basis of required stiffness. Time period is assumed to be sec. Stiffness of : KN/m Stiffness of : KN/m Stiffness of : KN/m Fig. A D Model of -storey office building Fig. shows mathematical model of -storey building prepared in STAAD Pro software. The building is an ordinary moment resisting frame, located in zone V with response reduction factor as. The building is resting on a medium soil. Comparative study with and without isolator: TABLE II FREQUENCY OF BUILDING WITH AND WITHOUT ISOLATOR Mode Frequency(Cycles/sec) Fixed Base........................ Description of Building: A eight-storey reinforced concrete office building is located on a medium soil Storey height : m Size of beams :.m x.m Size of columns :.m x.m Thickness of wall :.m Thickness of slab :.m Dead load : KN/m Live load :. KN/m Density of concrete : KN/m Modulus of elasticity : N/mm fck : N/mm fy : N/mm Span width in X direction : m ( bay) Span width in Z direction :.m ( bay) By a static analysis using the software (STADDPro program) the loads are computed for all the columns at their, where the bearings are to be installed. The maximum load on column Table II shows values of frequencies for their respective modes that are obtained by dynamic analysis of structure by response spectrum method for building with fixed and building isolated with different isolators.

International Journal of Scientific & Engineering Research, Volume, Issue, December- ISSN - Frequency(cycles/sec) - mode with and without isolator Spectral Acceleration - Mode with and without isolator Mode.... Frequency(cy cles/sec). Spectral Acceleration Frequency(cycles/sec). Frequency(cy cles/sec)... Frequency(cy cles/sec) Mode. Spectral Acceleration Spectral Acceleration Spectral Acceleration. Mode Fig. Comparative graph of Frequency-mode no. mode Fig. shows Frequency (cycles/sec)-mode shape graph. It is seen that frequency has reduced due to insertion of isolators in a building. Fig. Mode-spectral acceleration graph TABLE III SPECTRAL ACCLERATION OF BUILDING WITH AND WITHOUT ISOLATOR Mode Fixed...... Spectral Acceleration............ Fig. shows mode-spectral acceleration graph of building with fixed and with isolators. TABLE IV PEAK STOREY SHEAR OF BUILDING WITH AND WITHOUT ISOLATOR...... Floor Table III shows spectral acceleration values in different modes. Values shows that acceleration reduces in fundamental modes by providing isolators. Fixed.......... Peak Storey Shear(KN).............................. Table IV shows Peak storey shear values for isolated and non isolated building. Base shear is an important parameter to be extracted in response spectrum method.

International Journal of Scientific & Engineering Research, Volume, Issue, December- ISSN - Table V shows comparative values of avg. displacement with different isolators and without isolators. It can be seen that displacement has increased after provision of isolator. Peak Storey Shear(KN) - Floor wih and without isolator Avg. Displacement(cm) - Floor with and without isolator Floor Fixed Peak Storey Shear (KN) Avg. Displacement (cm) Peak Storey Shear (KN) Peak Storey Shear (KN) Floor Avg. Displacement (cm) Avg. Displacement (cm) Avg. Displacement (cm) Fig. Floor No.-Peak storey Shear Graph Fig. shows values of peak storey shear at different floors for isolated and non isolated building. It is seen that shear is maximum at the. Fixed......... Avg. Displacement(cm).................... Fig. Avg. displacement-srotey no. graph for isolated and non isolated building Fig. shows values of dispacement at different storey for isolated and non isolated building. Displacement increases with the height of building. TABLE V AVERAGE DISPLACEMENT OF BUILDING WITH AND WITHOUT ISOLATOR Floor TABLE VI STOREY DRIFT OF BUILDING WITH AND WITHOUT ISOLATOR Floor................... Storey Drift(cm)...........................

International Journal of Scientific & Engineering Research, Volume, Issue, December- ISSN - Table VI shows values of storey drift at different storey. It is seen that storey drift is maximum at m height. ) Storey Drift (cm) - Floor with and without isolator ). Floor Storey Drift(cm).. ) Storey Drift(cm)... ) Storey Drift(cm).. [] A. Calabrese, G. Serino, S. Strano and M. Terzo(), Investigation of the Seismic Performances of an FRBs Base Isolated Steel Frame through Hybrid Testing, Proceedings of the World Congress on Engineering, Vol III, WCE, July -,, London, U.K. [] A. Dusi, M. Mezzi, K. Fuller, The Largest Base-Isolation Priject in the World, The th World Conference on Earthquake Engineering, October -,, China. [] A.B.M.Saiful Islam, M. Jameel, Syed Ishtiaq Ahmad, Mohd Zamin Jummat(), Study on Corollary of Seismic Base Isolation System on Buildings with Soft Storey, International Journal of Physical Sciences, Vol.(),pp. -, June, [] Chauhan Kalpesh M. and Dr. B.J.Shah(), Excel Spreadsheet for Design of Lead Rubber Bearing uses for Seismic Isolation of Bridges, International Journal of Advanced Engineering Research and Studies, Vol.II, Issue III, April-June /- [] Dimitrios Konstantinidis, James M. Kelly and Nicos Makris, Experimental Investigation on the Seismic Response of Bridge Bearings. [] Evany Nithya S., Dr. Rajesh Prasanna P, Moment Resisting Frame with Rubber Base Isolation for Development of Earthquake Resisting Structures, International Journal of Modern Engineering Research, Vol., Issue, July-August pp--. [] Ganga Warrier,Balamonica K., Sathish Kumar K and Dhanalakshmi(), Study on Laminated Rubber Bearing isolators for Seismic Protection of Structures, International Journal of Research in Engineering and Technology, Volume :, Issue :,Feb.-. [] Harshita. R, A. Soundarya, Krishnareddygari Prathima, Y. Guruprasad(), Seismic Analysis of Symmetric RC Frame Using Response Spectrum Method and Time History Method, International Journal of Scientific Research and Education, Volume, Issue, March, pp -. [] J.C. Ramallo, E.A Johnson, AM. ASCE and B.F. Spencer Jr. M. ASCE, Smart Base Isolation Systems, Journal of Engineering Mechanics, October. [] Julie S, Sajeeb R, Performance of Base Isolators and Tuned Mass Damprs in Vibration Control of a Multistoried Building, IOSR Journal of Mechanical and Civil Engineering, ISSN - Vol., Issue (Sep-Oct ) PP -. [] K S Sable, J S Khose and V P Kulkarni(), Comparison of Different Bearing Types Performance in Multistoried Building, International Journal of Engineering and Innovative Technology (IJEIT) Volume, Issue, April. [] Katsumi Karita, Shigeru Aoki, Yuji Nakanishi, Kazutoshi Tominaga, Mitsuo Kanazawa, Experimental Study of Base Fig. Comparative graph of storey drift for isolated and non isolated building Fig. shows variation of storey drift at different storey level. Storey drift has reduced in isolated building as compared to non isolated building Conclusion: with and as compared to the fixed structure. Displacement has increased in all three isolators compared to the non isolated structure. The Avg. displacement is maximum in Lead Rubber Bearing as compared to and. Storey drift has reduced considerably by provision of isolator. The reduction in storey drift at m height are %,% and % respectively for, and structures as compared to the non isolated structure. It can be concluded that performance of isolated building is better compared to the non isolated building. Performance of Lead Rubber Bearing is better compared to the High Damping Rubber Bearing and Low Damping Rubber Bearing. References: Storey Drift(cm). Dynamic Response Spectrum Analysis is carried out for -storey office building. The structure is analysed with fixed and with different isolator. Comparative study of different parameters like frequency, spectral acceleration, shear, displacement and storey drift is carried out without provision of isolator and with provision of different isolators. From the summary of results, it can be concluded that: ) Frequency has reduced in isolated building as compared to the fixed building. Fundamental mode is more effective in seismic analysis. Frequency is minimum in structure in fundamental mode as compared to and. ) Acceleration has reduced when isolators are provided. structure gives least acceleration compared to other two types of isolators. ) The shear reduces considerably in isolated structure. There is % reduction in shear when structure is isolated with as compared to the fixed building. The reduction in shear are % and % respectively when structure is isolated

International Journal of Scientific & Engineering Research, Volume, Issue, December- ISSN - Isolation System for Small Equipmens and its Evaluation, Internaional Journal of Engineering Research and Applications(IJERA) ISSN: -, Vol., Issue, May-June, pp. - page [] R.S. Jangid, Performance of Base Isolation Systems for Asymmetric Building Subject to Random Excitation,. [] S. Etedali, M.R. Sohrabi, Torsional Strengthening of Base Isolated Asymmetric Structures by Increasing the Flexible Edge Stiffness of Isolation System, International Journal of Civil and Environmental Engineering, Vol., N:. [] S.J Patil, G.R. Reddy, State Of Art Review-Base Isolation System for Structures, International Journal of Engineering Technology and Advanced Engineering, ISSN -, Vol., Issue, July. [] Sarvesh K. Jain, Shashi K. Thakkar, Application of Base Isolation for Flexible Buildings, th World Conference on Earthquake Enginnering, August -, Paper No. [] Syed Ahmed Kabeer and Sanjeev Kumar K.S(), Comparison of Two Similar Buildings with and without Base Isolation, International Journal of Advanced Research, Ideas and Innovations in Technology, Volume I, Issue I, Oct-.