Seismic Base Isolation of RC Frame Structures With and Without Infill

Similar documents
Assistant Professor, Applied Mechanics Department, Government College of Engineering, Amravati, India 2

Pushover Analysis of High Rise Reinforced Concrete Building with and without Infill walls

Analysis of Seismic Pounding between Adjacent Buildings

Seismic Analysis of Steel Frames with Different Bracings using ETSBS Software.

EARTHQUAKE ANALYSIS OF A G+12 STOREY BUILDING WITH AND WITHOUT INFILL FOR BHUJ AND KOYNA EARTHQUAKE FUNCTIONS

COMPARATIVE STUDY OF EFFECT OF INFILL WALLS ON FIXED BASE AND BASE ISOLATED REINFORCED CONCRETE STRUCTURES

Result Analysis of Multistorey Building by Using Response Spectrum Method for Floating Column

SEISMIC RESPONSE OF A MID RISE RCC BUILDING WITH SOFT STOREY AT GROUND FLOOR

TO STUDY THE PERFORMANCE OF HIGH-RISE BUILDING UNDER LATERAL LOAD WITH BARE FRAME AND SHEAR WALL WITH OPENINGS

COMPARITIVE STUDY OF BASE ISOLATORS AND VISCOUS FLUID DAMPERS ON SEISMIC RESPONSE OF RC STRUCTURES

BEHAVIOURAL STUDY OF STIFFNESS IN SOFT STOREY BUILDINGS WITH DIFFERENT INFILLS

Torsional and Seismic Behavior of Shear Wall Dominant Flat Plate Buildings

Study on the Effect of LRB Isolators on Different Asymmetric Plans of RC Structure

Earthquake Resistant Design for Low Rise Open Ground Storey Famed Building

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 05, 2016 ISSN (online):

Analysis of friction pendulum bearing isolated structure

PERFORMANCE BASED SEISMIC ANALYSIS OF RC BUILDING USING SOFT STOREY CONSIDERATION

SEISMIC BEHAVIOUR OF RC BUILDING RESTING ON PLAIN AND SLOPING GROUND WITH BRACINGS AND SHEAR WALL

Department of Civil Engineering, SKP Engg. College, Tiruvanamalai, TN, India

BASE ISOLATION OF MASS IRREGULAR RC MULTI-STOREY BUILDING

Effect of Shear Wall Sections on Multistorey Building with Satellite Bus-Stop having Floating Columns with Top Soft Storey

EFFECTS OF P-DELTA ON HIGH RISE BUILDINGS LOCATED IN SEISMIC ZONES

Earthquake Behavior of RCC Building for Various Shear Wall Configurations

Seismic Performance of Multistorey Building with Soft Storey at Different Level with RC Shear Wall

Seismic Base Isolation in Reinforced Concrete Structures

Alternate Arrangement of Different Base Isolation System for Seismic Protection of Building

Study On Performance Of Regular And Vertically Irregular Structure With Dampers, Shear Wall And Infill Wall

Nonlinear Dynamic Analysis of Base Isolated Reinforced Concrete Building

Comparative Study of Equivalent Static Analysis and Response spectrum analysis on Flat Slab Using Etabs

Effect of Base Isolation in Multi-Storeyed RC Building

SSRG International Journal of Civil Engineering ( SSRG IJCE ) Volume 4 Issue 6 June 2017

SEISMIC ANALYSIS OF MULTISTOREYED RC BUILDING DUE TO MASS IRREGULARITY BY TIME HISTORY ANALYSIS

International Journal of Advance Engineering and Research Development SEISMIC ANALYSIS ON BUILDING WITH HORIZONTAL AND VERTICAL IRREGULARITIES

Comparative Study of Multi-storeyed RC Building With Open Ground Storey Having Different Type Infill Walls

MODAL PUSHOVER ANALYSIS OF RC FRAME BUILDING WITH STAIRCASE AND ELEVATOR CORE

Seismic Performance Of R C Flat-Slab Building Structural Systems

RESPONSE SPECTRUM ANALYSIS OF BOTTOM RIGID BEAM STOREY AND INTERMEDIATE SOFT STOREY HAVING MOMENT TRANSFER BEAMS

ANALYSIS AND EVALUATION OF STRUCTURAL SYSTEMS WITH BRACING AND SHEAR WALL

DYNAMIC ANALYSIS OF MULTI-STOREY BUILDING

Effect of Mass and Stiffness of Vertically Irregular RC Structure

A Study on Positioning of Different Shapes of Shear Walls in L Shaped Building Subjected to Seismic Forces

Analysis of Multi-Storey Building by Using Coupled Shear Walls

Performance of Multi-story RCC structure with Floating Column

COMPARATIVE STUDY ON DESIGN RESULTS OF A MULTI-STORIED BUILDING USING STAAD PRO AND ETABS FOR REGULAR AND IRREGULAR PLAN CONFIGURATION

RESPONSE SPECTRUM ANALYSIS OF MULTI- STOREY BUILDING WITH FLOATING COLUMNS

Effect of Openings in Shear Wall

Comparative Analysis of Moment Resisting Frames of Steel and Composite Materials

Index terms Diagrid, Nonlinear Static Analysis, SAP 2000.

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

SEISMIC ANALYSIS OF BOTTOM RIGID BEAM STOREY AND INTERMEDIATE SOFT STOREY HAVING MOMENT TRANSFER BEAMS

Seismic Analysis of Earthquake Resistant Multi Bay Multi Storeyed 3D - RC Frame

Behaviour of RCC Multistorey Structure With and Without Infill Walls

Evaluation of Effective Location of Pendulum Tunned Mass Dampers for Building with Mass Irregularity

Analysis and Design of an Earthquake Resistant Structure using STADD. Pro

STUDY ON EFFECTS OF P-DELTA ANALYSIS ON RC STRUCTURES

Analysis of Building with Soft Storey during Earthquake

Seismic Analysis of Multi Storey Building with Flat Slab Resting on Plain and Sloping Ground

IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 09, 2014 ISSN (online):

SEISMIC ASSESEMENT OF RC FRAME BUILDINGS WITH BRICK MASONRY INFILLS

EVALUATION OF SEISMIC DESIGN MAGNIFICATION FACTOR FOR REGULAR AND L SHAPE OPEN GROUND STOREY BUILDINGS

COMPARISON BETWEEN FRICTION PENDULUM SYSTEM AND LAMINATED RUBBER BEARING ISOLATION SYSTEM

STUDY ON LAMINATED RUBBER BEARING BASE ISOLATORS FOR SEISMIC PROTECTION OF STRUCTURES

Seismic behavior of Structures with Different Diaphragms and Infill Walls

Seismic Analysis of a High-rise RC Framed Structure with Irregularities

Effect of Diaphragm Openings in Multi-storeyed RC framed buildings using Pushover analysis

Seismic Response of RC Framed Structures Having Plan and Vertical Irregularities with and Without Masonry Infill Action

Research Article Volume 6 Issue No. 7

COMPARATIVE STUDY ON GFRP AND STEEL BAR REINFORCEMENT IN MULTISTOREY BUILDING UNDER SEISMIC LOAD BY PUSHOVER ANALYSIS

PARAMETRIC STUDY ON VERTICAL IRREGULAR HIGH RISE REINFORCED CONCRETE FRAMED BUILDING

PERFORMANCE BASED ANALYSIS OF R.C.C. FRAMES

COMPARATIVE STUDY ON REGULAR & IRREGULAR STRUCTURES USING EQUIVALENT STATIC AND RESPONSE SPECTRUM METHODS

Seismic Analysis of Buildings with Shear Wall having Horizontal Irregularity

Stability Analysis of Multi-story building with underneath Satellite Bus Stand having intermediate soft-story and Floating columns

SEISMIC PERFORMANCE OF FLAT SLAB WITH DROP AND CONVENTIONAL SLAB STRUCTURE

PUSHOVER ANALYSIS OF RC BUILDINGS WITH SHORT LEG SHEAR WALL ON PLAN SYMMETRY AND VARRYING SOIL TYPE IN ZONE II REGION

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 04, 2016 ISSN (online):

IJSRD - International Journal for Scientific Research & Development Vol. 5, Issue 06, 2017 ISSN (online):

STUDY OF SEISMIC PERFORMANCE OF RC BUILDING WITH FLAT PLATE INFLUENCED BY CONCRETE WALL

COMPARATIVE STUDY ON FIXED BASE AND BASE ISOLATED FOR BUILDING ON SLOPING GROUND

PERFORMANCE BASED EVALUATION OF FRAMED REINFORCED CONCRETE SHEAR WALLS BY PUSHOVER ANALYSIS

COMPARISON OF REINFORCED CONCRETE FRAMES MODELLED WITH AND WITHOUT INFILL WALLS

IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 07, 2014 ISSN (online):

Soil structure interaction of RC building with different foundations and soil types

Evaluation of Seismic Behavior for Multistoried RC Moment Resisting Frame with Open First Storey

THE INTERNATIONAL JOURNAL OF SCIENCE & TECHNOLEDGE

Analysis of steel braced symmetrical RCC building with designed I-sectional rubber base isolator

Seismic Analysis of RC Framed Building for Different Position of Shear wall

Dynamic Analysis of Reinforced Concrete Framed Structures with Infill Wall Chethana M S Assistant Professor Department of Civil Engineering

STUDY OF SEISMIC BEHAVIOUR OF BUILDINGS WITH FLAT SLAB

Evaluation of Response Reduction Factor and Ductility Factor of RC Braced Frame

SEISMIC ANALYSIS OF HIGH RISE BUILDING WITH IS CODE and IS CODE

Seismic Analysis and Design of Vertically Irregular RC Building Frames

NON LINEAR STATIC ANALYSIS OF DUAL RC FRAME STRUCTURE

STUDY ON BEHAVIOUR OF RC STRUCTURE WITH INFILL WALLS DUE TO SEISMIC LOADS

Seismic Behavior of High Rise Building for Soft Soil in All Seismic Zones Shaik Fayaz 1 Mrs. B.Ajitha 2

A Comparative Study of Stress Parameters Obtained by STAAD-Pro and ETAB

ENHANCING RESISTANCE CAPACITY OF SOFT STOREY BUILDING BY MEANS OF SHEARWALL INCORPORATED WITH STRUT

SEISMIC DESIGN OF STRUCTURE

Base Isolation In Seismic Structural Design

Seismic Study of Multistorey RC Building With Different Bracings

Transcription:

Seismic Base Isolation of RC Frame Structures With and Without Infill Sunil Shirol 1, Dr. Jagadish G. Kori 2 1PG student, Dept. of Civil Engineering, Government Engineering College, Haveri, Karnataka, India 2Head of Department, Dept. of Civil Engineering, Government Engineering College, Haveri, Karnataka, India ---------------------------------------------------------------------***--------------------------------------------------------------------- Abstract Many of the buildings subjected to earthquake increasing acceleration causes severe damage to the suffer severe damage. Hence it is necessary to prevent the structures from the earthquake. Base isolation is one such type of method used to prevent the damage to the structure. The pain principle behind base isolation is to separate substructure from superstructure. In present study a G+6 storey model with and without masonry infill are considered. Lead rubber bearing and friction type isolators were used. The infill was modeled as single diagonal strut. The static and response spectrum analysis are carried out using ETABS-2016. From the study it was concluded that provision of isolators increased the natural time period which eliminates the probability of resonance. The base shear and the storey drifts got reduced significantly while the displacement increased which is due to the flexibility imparted to the structure. The consideration of infill action increased the base shear while the displacement and inter storey drifts showed decreasing trend. Key Words: Base Isolation, Infilled wall, Lead rubber Isolator, Friction Type Isolator, Static Analysis, Response Spectrum. 1. INTRODUCTION Earthquake is a natural calamity which has caused severe damage to life and property from past till today. However earthquake forces are of shorter duration but causes severe damage. Hence seismic design has gained importance now a day. In low to medium rise buildings the natural frequency is much lower as compared to that of earthquake frequency. Hence the building acts as amplifier and the acceleration of each floor will increase to the top. Due to this effect member stresses and drifts increases. The columns are subjected to larger loads and moments. The structure and its occupants. This acceleration can be kept in limit by increasing the rigidity of the structure but it is uneconomical and not suitable for practical conditions. Hence the techniques like base isolation, provision of shear wall etc are getting more importance. Many of the comparative studies have been done on seismic base isolation and the masonry infill. Some of them are discussed below. Mohammed Asim Khan et al. [1] studied the influence of base isolation and the infill masonry (masonry modeled as shells) on behavior of L-shape plan irregularity buildings. A total 9 no of models asymmetrical in plan are considered for the analysis. The modeling of structure is carried out in SAP2015 by using LRB isolation system and the infill masonry. He concluded that use of LRB isolator reduced displacement of top storey and storey shears, while modal time period of structure increased. Nitya M, Arati S [2] studied the response of RC building under particular earthquake motion and comparison of results for base isolated and fixed structure. In this study a 7 storey RCC frame buildings with and without base isolation is considered. The EL-Centro earthquake data is considered for time history analysis. Three type of models fixed base, rubber isolation and friction isolators are respectively and are analyzed using SAP2000 structural software. The base isolation provided increased the natural time period while the reduction of base shear is observed in the building. Shameena Khannavar et al. [3] carried out modeling and performed analysis of base isolated and fixed base structures. A G+9 storey building with plan and vertical irregularity is considered for the following study. The ETABS software is used for modeling and the analysis is done for 2017, IRJET Impact Factor value: 5.181 ISO 9001:2008 Certified Journal Page 1783

Static and Response spectrum method of analysis. The provision of LRB isolator reduced storey drifts, storey acceleration and base shear. Rahul P. Rathi et al. [4] investigated the effect of central and end openings in infill on response of RC building. A 4 storey building and nature of earthquake. The second is dissipation of energy through mechanics which results in increased damping of building. The increased damping results in lesser deformation of the structure. The time period shift is shown in Fig-1. building model is prepared in STAD-PRO. The method analysis used is Static method of analysis. The infill is modeled by using Mainstone s empirical formula for with and without opening. The comparison of results like deflection, axial force and moments is carried out. From this study he they concluded that Compared to building having opening at centre the building with end opening shows lower deflection values. Mohammad H. Jinyal et al. [5] studied the effect of stiffness variation of masonry infill for linear static and nonlinear dynamic analysis by diagonal strut modeling of infill. A G+9 storey building is modeled in ETABs considering various stiffness values. Both static and dynamic analysis was carried out and it was observed that the infill masonry will alter the response of building and the soft storey effect can be minimized by providing periphery wall. The masonry infill has considerable effect on the behavior of structure but generally this effect has been neglected. But in some of the literature above they have considered the infill action and base isolation separately. Hence there is a need to study the effect of base isolation along with infill action. The Fig-1 Effect of base isolation on spectral acceleration 1.2 Lead Rubber Bearing It is an elastomeric type of bearing made up of successive layers of low damping rubber and steel plates. A cylindrical lead core is provided at centre as an energy dissipating device as shown in Fig-2. The lead core is provided to take care of shear and to provide initial rigidity against ground motion. The steel plates are provided to give large plastic deformation. This type of system results in lesser deformations lateral direction as compared to other systems because of its energy dissipation. present case aims at the investigation of base isolation effect on bare frame and frame with infilled wall. 1.1 Base Isolation The main concept of base isolation is separation of superstructure from sub-structure which is in direct contact with ground. The main aim of providing isolation is to minimize the vibrations produced in the structure. When the base isolation system is provided in the structure two important phenomenons are observed, first time period shift of building which increases the natural time period of Fig-2 Schematic representation of LRB isolator [6] buildings thus reducing the base shear. The reduction in base shear is dependent on fixed base time period of 2017, IRJET Impact Factor value: 5.181 ISO 9001:2008 Certified Journal Page 1784

The concept of sliding bearing is also combined with the concept of a pendulum type response, obtaining a conceptually interesting seismic isolation system known as friction pendulum system FPS as shown in Fig-3. In FPS [6] isolation is achieved by means of an articulated slider on spherical, concave chrome surface. Fig-4 load transfer mechanism of frame system having with and without infill. 2. OBJECTIVES The prime objective of the present work is to analyze a G+6 storey structure and to carry out the comparison of results for Time period, Base shear, Displacement and inter storey drifts for 1. Bare frame buildings with base fixed & base Fig-3 Friction Pendulum System Isolator [6] 1.2 Infill Frame The RC frames are commonly analyzed as bare isolated. 2. Infill frame buildings with base fixed & base isolated. 3. MODEL DESCRIPTION frame even with presence of infill. The infill panel is considered as non-structural element and hence they are neglected in design process due to incomplete knowledge on behavior of infill with RC frame. The presence of infill wall alters the load transfer mechanism from frame action in to truss action (shown in Fig-2) which reduces the member forces and moments. The infill acts as a tie member between beam and columns. Hence compressive forces transfer from joint to joint and thus load transfer mechanism is altered. The infills may be integral or non integral part of the structural system. below. The plan of the building used in the analysis is given Fig-3 Plan of the building in ETABS 2017, IRJET Impact Factor value: 5.181 ISO 9001:2008 Certified Journal Page 1785

A (G+6) storey building placed in Zone IV on hard soil is taken and analysis of structure including seismic evaluation is done as per IS 456: 2000 and IS 1893 (part 1): 2002 using ETABS 2016 software. Plan is of 4 no of bays in both directions. The bay size in X direction is 5m and along Y direction it is 4m. Table-1 Building data considered 3.2 Properties of Isolators The lead rubber isolator and the friction type isolators were used in the study. The properties of lead rubber isolator system are provided in the table-3. Table-3 Properties of lead rubber Isolator Property Value Parameter Value Effective horizontal stiffness kh 1416 kn/m Typical floor height 3.5m Size of beams 230mm x 450mm Post yield stiffness Ku 11940 kn/m Column size 300mm x 600mm Vertical stiffness kv 530000 kn/m Thickness of slab 150mm Short term yield force 46 kn Wall thickness 230mm Concrete grade M-30 Steel grade Fe -500 Post yield stiffness ratio 0.1 Effective damping 0.1 Seismic zone IV (0.24) Similarly the properties of the friction type isolator are given 3.1 Loads considered The dead load of the structure includes the self in table-4 Table-4 Properties of friction type Isolator weight of members i.e. beam, columns and slab and also the floor finishes. The dead loads are calculated on the basis of unit weights of materials given in IS 875 (Part I). The dead loads on the structure include the self weight of beams, columns, slabs, walls and other permanent members. Imposed loads are assumed in accordance with IS 875(Part Property Effective horizontal stiffness kh Post yield stiffness Ku Vertical stiffness kv Value 2000 kn/m 15000 kn/m 600000 kn/m II). Table-2 Loads considered Loading Floor Terrace Live load 3.0 KN/m 2 1.5 KN/m 2 Friction factor (min) 3% Friction factor (max) 5% Radius of sliding surface 1.5m Floor finish 1.5 KN/m 2 1.5 KN/m 2 Wall load 16 KN/m 4 KN/m Percentage of live load 50 % (As per IS: 1893 (Part-ɪ) 2002) taken The structures are modeled in ETABS software. The 3-D models of bare frame structure, isolated structure and structure with masonry infill are shown in the below figures. 2017, IRJET Impact Factor value: 5.181 ISO 9001:2008 Certified Journal Page 1786

The figure-4 shows the 3-D view of the building with lead rubber bearing isolation systems at the base of column. Fig-6 3-D view of infilled frame structure Analysis of the structures: Two basic methods of analysis Fig-4 3-D view of lead rubber isolated structure The fig-5 shows the 3-D view of structure with friction pendulum system of isolation provided at the base of the columns. are adopted for the models considered. Equivalent Static and response spectrum analysis were carried out and the results were obtained for the two methods respectively. 3.3 Static Analysis The design lateral force is first computed for the structure as a whole. This design lateral force shall then be distributed to various floor levels. The overall design seismic force thus obtained at each floor levels shall then be distributed to various lateral load resisting elements. The design base shear can be estimated as per IS 1893 (part ɪ): 2002, clause 7.5.3, The design horizontal seismic coefficient for a structure shall be determined as per IS 1893 (part ɪ): 2002, clause 6.4.2, The fundamental natural period of vibration Fig-5 3-D view of friction type isolated structure The fig-6 shows the structure with masonry infill modeled in ETABS. The masonry infill is modeled as diagonal strut. The Mainstone s equation was used to find the width of diagonal strut. considering without brick infill panels and with brick infill panels for a moment-resisting frame building is estimated as per the clause 7.6.1 and 7.6.2 of IS 1893 (part ɪ):2002. The horizontal design lateral force is then distributed to various lateral load resisting elements in the building as per the clause 7.7.1 of IS 1893 (part ɪ):2002. 2017, IRJET Impact Factor value: 5.181 ISO 9001:2008 Certified Journal Page 1787

3.4 Response Spectrum Analysis Table-4 Comparison of Natural time period It is a plot of maximum response of the earthquake of SDOF as behavior of its frequency or natural period for a given value of damping. Response spectrum may be performed either by design spectrum or by site design spectrum. It is a linear dynamic analysis method. The earthquake design spectrum should satisfy certain Time periods (sec) Fixed base LRB FS Bare Fame 1.81 3.129 2.924 Infill frame 0.316 1.363 1.257 requirements for any elastic system. The spectrum unevenness is due to the differences in the frequency of the ground during excitation. ETABS gives the response spectrum for the input ground motion giving to the structure and also the structure response for the earthquake motion. The typical response spectrum for 5% damping for three types of soil according to IS 1893 (part 1): 2002, is as shown. Chart-1 Natural time period for fixed and isolated structures Table-5 Comparison of Time period for bare and infill frames Modal time periods (sec) Bare frame Infill frame Mode 1 1.81 0.316 Mode2 1.453 0.276 Mode3 1.419 0.217 Fig -5 Response spectrum as per IS 1893 (part 1): 2002. 4. RESULTS AND DISCUSSIONS The results for time period, base shear, displacement and storey drifts are obtained and they are tabulated below. LRB- Lead rubber bearing isolated structure FS- Friction sliding type isolated structure 4.1 Natural time period The Table-4 and Table-5 below show the natural time period of fixed base and base isolated structure for both bare frame and masonry infilled structures. Chart-2 Variation of time period for bare & infill 2017, IRJET Impact Factor value: 5.181 ISO 9001:2008 Certified Journal Page 1788

From chart-4 and chart-5 it is clear that the provision of isolation system increases the natural time period of the structure thus minimizing the possibility of resonance effect. It can be said that the time period of isolated structure was increased by 45% for LRB isolation and 42% for FPS isolation in bare frame structure and by 75% for LRB isolation and 70% for FPS isolation in infill frame structure. 4.2 Base shear The chart-3 to chart-5 shows the values of base shear and the comparison of the base shear for bare frame and infill frame with different isolation systems. Chart-5 Variation of base shear for bare & infill models From chart-3 and chart-4 it is clear that the introduction of base isolation system reduces the base shear by 50% in bare frame and 70 % for in filled frames. The consideration of infill increased the base shear by50% which is due to the increase in the mass of the structure. 4.3 Storey displacements The storey displacement for the isolated building increases due to the increase in the flexibility of the building. The variation of displacement for bare and infill frame models is shown in the below charts. 1-A fixed base model by static method 2-A fixed base model by response spectrum method Chart-3 Variation of base shear for bare & isolated models 1-B LRB base model by static method 2-B LRB base model by response spectrum method 3-A FPS base model by static method 3-B FPS base model by response spectrum method Chart-4 Variation of base shear for infill & isolated models Chart-6 Variation of displacement for bare frame models 2017, IRJET Impact Factor value: 5.181 ISO 9001:2008 Certified Journal Page 1789

Chart-7 Variation of displacement for infill frame Chart-9 Variation of storey drift for bare frame model by static and response spectrum method Chart-8 Variation of displacement for bare & infill frame Chart-10 Variation of storey drift for infill frame model by static and response spectrum method From the above chart it can be seen that the provision of isolation system increases the displacement at the base but the variation of displacement from bottom storey to top storey is reduced hence all the floors undergo relatively same displacement. 4.4 Storey drifts The charts from chart-9 to chart-10 shows the variation of the inter storey drifts for fixed base and base isolated structures for bare frame and infill frame models. Chart-11 shows the variation of storey drift for bare frame and infill frame structures by static and dynamic analysis. Chart-11 Variation of storey drift for bare & infill frame 2017, IRJET Impact Factor value: 5.181 ISO 9001:2008 Certified Journal Page 1790

The inter storey drifts of bare frame and infill models got reduced when the base isolation is provided. The presence of infill reduced the inter storey drifts when compared to bare frame due to increase in the stiffness. The storey drift is maximum between base and the first storey where the isolation systems are provided and decreases as the storey level increases from bottom storey to top storey. 4. CONCLUSIONS The time period of the structure increases in every model for base isolated case when compared to fixed base condition. The natural time period increases by 1.319 and 1.114 sec for lead rubber isolator and friction isolator respectively in bare frame structure. In infilled structure the time period increased by 1.047 and 0.941 sec respectively The base shear reduces by 50% for bare frame models and 70% for models with masonry infill in static method. The base shear reduces by 46 % and 42% in bare frame and by 71% and 65% for infill structure for rubber isolator and friction isolator respectively by response spectrum method. The value of base shear is high in case of infill structure, which is due to the increase in mass of the structure. The increase in the flexibility of the bare and infill frame structures with isolation has increased the displacement of the structure at base. The increase in displacement at base is by 21.334 mm and 16.159 for LRB and FPS in static analysis and 19.38 mm and 14.48mm for LRB and FPS isolator respectively for response spectrum analysis. But the variation of displacement from bottom storey to top is reduced. With the base isolation system, inter story drifts are reduced or almost negligible. This reduced story drifts enables both bare and infill frame structures structural and non structural parts. The story-drifts obtained for various models are well within the limit as per IS 1893 (Part -ɪ): 2002, clause 7.11.1. The presence of infill reduces the values of storey displacement and storey drifts when compared to bare frame structure. REFERENCES 1. Mohammed Asim Khan, Prof. Shaik Abdulla (2014), Non-linear Static Analysis of 3-D Framed Asymmetric Buildings with Lead Rubber Isolator using SAP2000, International Journal of Engineering Research & Applications, Vol-4, Issue-9, pp 87-91. 2. Nitya M, Arathi S (2016), Study on Earthquake Response of a RC Building with Base Isolation, International Journal of Science and Research, Vol-5, Issue-7, pp 1002-1005. 3. Shameena Khannavar, M. H Kolhar (2016), Seismic Analysis of RC Structure Using Base Isolation Technique, International Research Journal of Engineering and Technology, Vol-3, Issue-7, pp 2320-2327. 4. Rahul P Rathi, Dr. Pagade (2012), Study of Masonry Infilled RC Frames With and Without Opening, International Journal of Scientific and Engineering Research, Vol-3, Issue-6, pp 1-7. 5. Mohammad H Jinyal, V R Patel (2014), Analysis of RC Frame With and Without Infill with Different Stiffness with Central Opening, International Journal of Research in Engineering and Technology, Vol-3, Issue-6, pp 76-83. 6. Dia Eddin Nassani, Mustafa Wassef Abdulmajeed(2015), Seismic Base Isolation In Reinforced Concrete Structures, International Journal of Research Studies in Science, Engineering and Technology, Vol-2, Issue-2, pp 1-13. to behave ideally stiff resulting in less damage to the 2017, IRJET Impact Factor value: 5.181 ISO 9001:2008 Certified Journal Page 1791

7. Alurwad Rajeshwarreddy R, Prof. Arshad Hashmi, Prof. Kulkarni V. P(2013), Seismic Behavior of Reinforced Concrete Frame With Infill Walls, International Journal of Engineering Research and Application, Vol-3, Issue-4, pp 1419-1423. 8. Dia Eddin Nassani, Mustafa Wassef Abdulmajeed(2015), Seismic Base Isolation In Reinforced Concrete Structures, International Journal of Research Studies in Science, Engineering and Technology, Vol-2, Issue-2, pp 1-13. 9. Mohammed Salman Maniyar, Mehaboob Baig Inamdar (2016), Seismic Evaluation of High Rise Building With and Without Base Isolation, International Journal for Scientific Research and Development, Vol-3, Issue-3, pp 1584-1587. 10. Prof. R. B Ghodke, Dr. S. V Admane (2015), Effect of Base Isolation for Building Structures, International Journal of Science, Engineering and Technology, Vol-4, Issue-4, pp 971-974. BIOGRAPHIES Sunil Shirol pursuing his M.Tech. in Civil Strutures from Government Engineering College, Haveri & obtained B.E. Civil from KLECET Chikodi. Dr. Jagadish G. Kori presently working as Professor in Government Engineering College, Haveri. He has obtained his PhD from IIT Bombay, M.Tech from NITK Suratkal & obtained B.E. Civil from B.V.B College of Engineering and Technology, Hubli. 2017, IRJET Impact Factor value: 5.181 ISO 9001:2008 Certified Journal Page 1792