Featuring Antimicrobial Protection

Similar documents
Featuring Antimicrobial Protection

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION HVAC PIPES AND TUBES

PREMIER Low Profile Induced Draft Cooling Tower Specifications

SITHE SUBMERSIBLE CHOPPER PUMPS BY BARNES. Excellence in Innovation.

SITHE SUBMERSIBLE CHOPPER PUMPS BY BARNES. Excellence in Innovation.

COMMERCIAL / INDUSTRIAL COOLING TOWER SIDE STREAM FILTER SYSTEMS

Fiberglass Cooling Towers

Goulds Two Stage, Horizontally Split Case Pump

Energy Efficient. & Cost Saving. Continuous Boiler Blowdown Package Heat Recovery Systems. 20 Models from 1,200 pph to 50,000 pph Capacity

Belt Systems & Belt Products

Rolairtrol Air Separator For Hot and Chilled Water Systems

White Paper. Fire Sprinkler Riser Corrosion. (May 2014) Jeffrey Kochelek (Engineered Corrosion Solutions, LLC) V.1.0.1

WELLMATE COMPOSITE PRESSURE TANKS WATER PURIFICATION TANKS & SYSTEMS - WELLMATE

Tubes and Pipes. Tubes and Pipes D-02

PRESSURE REGULATORS. GUIDE to REGULATORS and SERVO VALVES

Cash Valve. Type C-776. ASME Section VIII Air/Gas and Cryogenic, UV National Board Certified Safety Valve. Flow Control

[Amdt , 60 FR 50336, Sept. 28, 1995; 60 FR 54409, Oct. 23, 1995, as amended at 69 FR 3696, Jan. 26, 2004; 70 FR 56099, Sept.

Submersible Axial Flow Propeller Pumps

INDUSTRIAL SEPARATE BED DEIONIZER. FDI Series. High Purity Industrial Packaged System

Diffused Aeration Piping Equipment

INVITATION TO BID B I D F O R M. Please submit bid on or before 1:15 pm 101 North Halagueno Street May 30, 2014, at the office of the

LIQUID LEVEL SWITCHES

FLOOR DRAINS AWI MANUFACTURING

PAHT C pumps ATEX PAHT C pump

Bell & Gossett Air Management for Hydronic Heating and Cooling Systems A-307A

Pioneer Forced Draft Cooling Tower Specifications

INVITATION TO BID B I D F O R M. Please submit bid on or before 2:15 pm 101 North Halagueno Street June 6, 2013, at the office of the

Installation Guide BLUE904 PEX MUNICIPAL WATER SERVICE TUBING. We Build Tough Products for Tough Environments

FLOOR DRAINS AWI MANUFACTURING

K. All mechanical rooms shall be designed with a minimum 3-1/2 dropped floor.

SUGGESTED SPECIFICATIONS

COMPRESSOR INNOVATIVE, RELIABLE, AND COST-EFFECTIVE SOLUTIONS. ENERFLEX DELIVERS. PACKAGES KEY BENEFITS. Faster Gas to Market.

1. ARI 410 Standard for chilled water, hot water and steam coils. 2. ARI 430 Central Station Air Handling Units

Lifetime Guaranteed Construction with unique built-in installation and maintenance features

TM Series Induced Draft Cooling Tower Specifications

Pump Specifications 450 Series 1/2 hp Submersible Sump Pump

Electric Diaphragm Pumps Electric Operated Double Diaphragm Pump

HDG Turbotec. HDG Log wood boilers. Comfortable and safe. 340-litre fuel chamber. Log wood sizes up to 1-metre long

Air-Operated Double Diaphragm Pumps

5. AMCA 301 Method of Publishing Sound Ratings for Air Moving Devices. 6. AMCA 500 Test Methods for Louver, Dampers, and Shutters

Commercial. Softeners Filters Reverse Osmosis

Booster Pump Fundamentals. By: Bill Baglot

QUALITY ASSURANCE PROTOCOL (QAP)

Engineering Excellence

K-FLEX SOLAR SYSTEM SOLAR SYSTEM

Engineering Specifications

Engineering Specifications

Water Quality Specification for Power Supplies

VSX TECHNICAL BROCHURE

Benchmark Platinum Boilers

Sure-Grip System. A System with Benefits. Concrete Protection

SUMP / EFFLUENT PUMPS ARE SINGLE PHASE WITH PIGGYBACK FLOAT SWITCH. Max. Flow 44. Max. Head 20. Voltage 115

Aqua-Jet SURFACE MECHANICAL AERATOR The Aqua-Jet aerator is the most durable, highly efficient wastewater aerator on the market today. Since, more tha

Peppermill Renewable Energy Program

SPL Evaporative Condensers

Engineering Specifications

MAGNA-SKIN TM. Magnetic Products. Inside..

Air Management. For Hydronic Heating and Cooling Systems A-307A

designed from experience. manufactured by experts.

3 Stikit, Hookit & Hookit II Systems Discs, Disc Rolls, Sheet Rolls, Dispensers, Disc Hand Pads and Sanding Tools

Engineered Gasketing Products

G-FIRE GROOVED COUPLINGS

A. This Section includes exterior piping for vertical, direct-buried, ground-loop, heat-pump systems that operate between 23 and 104 deg F.

This is more than providing you with containers This is a relationship. We re here for you. We built it to last. We mean it. Here s your guarantee.


Unconventional Oil & Gas. Pumping solutions for multiphase mixtures in tight oil, thermal and shale applications

The Material Master Advantage

About Us. In business since JC Carter designed the first cryogenic submerged motor pump in of 4 Large Test Facilities in the World

Changes for the. TOHOPEKALIGA WATER AUTHORITY Standards, Specifications and Details

PFA Lined MTA Series ANSI Pumps

GENERAL CONTENTS SECTION I - NUCLEAR ISLAND COMPONENTS

General - Frequently Asked Questions

Specification Section XXXXX Interior Water walls

Technical Process Bulletin

Flygt N-Pumps 3085, 3102 & For reliable and efficient wastewater handling

Severe Service Technology, Inc.

SECTION HANGERS AND SUPPORTS FOR PLUMBING

RTM ACCESSORIES. MOLD SEALS ( Packing : 25LM Rolls ) Standard Dynamic Seal White. Medium Dynamic Seal Blue. Primary seal for Hollow Dynamic Seal

Technical Process Bulletin

For Heavy-Duty, High-Volume Ferrous Separation

POSITIVE DISPLACEMENT BLOWERS & VACUUM PUMPS. Water & Wastewater Treatment Solutions

INDUCED-DRAFT TWIN CROSSED-FLOW COOLING TOWER

1.02 RELATED SECTIONS: Water supply piping, water use piping, electrical, irrigation, foundations, site plans.

STANDARD SHELTER SPECIFICATIONS ATTACHMENT A

Valve Nest Filter with Time Clock Control Installation and Operation Manual

SUGGESTED SPECIFICATIONS Pump Frames through 64132

BRUTALLY STRONG AS A RHINO SHOULD BE

NOTES P: 888-H2O-LOGIC ( ) F:

SECTION TOILET AND BATH ACCESSORIES ADDENDUM NO.4

CST Series. STONESTEEL Water Storage Tanks for Hot and Cold Water Storage Hot Water Generators

C. ASSE 1013 Performance Requirements for Reduced Pressure Principle Backflow Preventers.

3-DEM and ASGCO FLO-CONTROL

Electrical Isolation

Overhaul Issues on Vertical Pumps

DIAGRAM FOR CALCULATING PIPE SIZES, DISCHARGE VELOCITIES AND LOSS OF HEAD IN STANDARD STEEL PIPE PIPE FRICTION LOSS CHART

SECTION (15150) - SANITARY WASTE AND VENT PIPING

UNIVERSAL PRODUCT LINE: STAINLESS STEEL MAG DRIVE PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE

University of Delaware

133 Series Self-Operated Regulators

YARWAY HANCOCK CONTINUOUS BLOWDOWN GLOBE VALVE SERIES 5505

Transcription:

Featuring Antimicrobial Protection Well Above The Rest

Amtrol Inc. invented the first pre-pressurized well tank over 50 years ago. This revolutionary product featured an innovative design using a hoop ring and groove to lock the diaphragm, liner and shell together in a totally unique way. This tradition of innovation continued with Amtrol s Next Generation Well-X-Trol, which utilized high strength steel to deliver a 150 psig working pressure - 20% higher than competitve well tanks to earn an industry leading 7 year warranty. Now Well-X-Trol is combining the patented Turbulator with patent pending antimicrobial liner protection to deliver Clean Water Technology in every tank. Well-X-Trol - the world s most trusted brand in well tanks; setting the standard for quality, reliability and performance. Amtrol App puts sizing and support at your fingertips. Available for iphone, ipad and Android. American Tube Products founded in West Warwick, Rhode Island 1946 pre-pressurized well tank Built current Rhode Island manufacturing facility indirect-fired Hot Water Maker Opened the Amtrol Education Center AMTROL registered ISO 9001 1963 1972 1980 1988 1992 1954 1967 1975 1986 1991 diaphragm expansion tank refrigerant gas cylinder Entered the commercial products business top coil indirect Hot Water Maker thermal expansion tank 2

The First and Still the Best. The complete line of Well-X-Trol well tanks includes inline, stand, underground, wall hung, horizontal and pump stand models. Contractors earn valuable rewards points for every Well-X-Trol well tank installed. Visit amtrolrewards.com for complete details. Acquired ALFA Cylinder Manufacturing in Portugal 1997 composite metal LP tank 2005 Launched Amtrol Rewards AMTROL registered ISO 9001:2008 2009 s on Tour mobile education center hits the road Introduced ASME for propane vehicles 2014 2003 AMTROL registered ISO 9001:2000 2007 Introduced XLite cylinder 2010 Launched Next Generation Well-X-Trol 2012 Launched HydroMax Hot Water Makers 2016 Amtrol 70th Anniversary 20 millionth well tank shipped 3

7 Year Warranty Installers asked for it - we delivered. A Well-X-Trol exclusive and the best warranty in the industry. High Strength Steel Deep-drawn domes are double the strength of rolled steel. Multi-Dome Construction Provides internal bracing for added strength. Prevents diaphragm over-extension. Heavy Duty Butyl Diaphragm The industry s thickest diaphragm provides extra strength and flexibility. Seamless design conforms exactly to the shell without stretching, creasing or forming bubbles that could trap water or sediment. Meets stringent FDA requirements. Positive Diaphragm Seal Unique hoop ring and groove design secures the diaphragm, liner and shell for added strength and reliability. Exclusive welding process eliminates rough spots and sharp edges that can damage the diaphragm and liner. Stainless Steel System High grade stainless steel withstands aggressive water conditions. Optional Pro-Access Piped to stand for fast, easy installation. 4

Well Above The Rest. 150 psig Working Pressure 20% higher rating than competitive well tanks. Every tank is pressure tested for added safety. Precharged to 38 psig for the most common pump cut-in pressure. Clean Water Technology in Every Patent-pending technology; Antimicrobial Liner and Turbulator work together to keep tank surfaces clean. Projection Welded Air Valve Eliminates leak paths found on threaded valves. Maintains air charge better than mechanical seals. Tuf-Kote HG Indoor/Outdoor Coating Stands up to the most severe conditions. Standard on all models; available in blue, tan and gray. Antimicrobial Liner Antimicrobial Liner Protection Neutralizes bacteria on contact. Safe, Silver-Ion technology only targets active microorganisms. Long lasting compound is molded into the water reservoir lining. Patent pending. Bacteria Water Silver Ion Release Liner Surface Fresh Water Turbulator Liner Silver Ions Patented Turbulator In-line Models Stand Models DuraBase Composite Stand Optional composite stand features patented design. UV resistant material is rugged and will never corrode. Available separately as a spacer for steel stand models. Fresh Water Turbulator Patented diffuser agitates incoming water stream. Water-jet scrubbing action prevents sediment buildup. Eliminates stagnant water in VFD applications. Helps extend the life of the tank. 5

Model InLine Models Diameter System (NPTM) System Drawdown (gallons) 30/50 40/60 50/70 WX-101 2.0.45 8 13 3 4 0.6 0.6 0.5 5 WX-102 4.4.55 11 15 3 4 1.4 1.2 1.0 9 WX-103 7.6.43 11 22 3 4 2.4 2.0 1.8 15 WX-104 10.3 1.00 15 18 1 3.2 2.8 2.4 20 WX-200 14.0.81 15 22 1 4.3 3.8 3.3 22 Tan and Gray: Available on all models. Use suffix T or G. Model Stand Models Diameter System (NPTF) System Drawdown (gallons) 30/50 40/60 50/70 WX-201 14.0.81 15 25 1 4.3 3.8 3.3 25 WX-202 20.0.57 15 32 1 6.2 5.4 4.7 32 WX-202XL 26.0.44 15 39 1 8.0 7.0 6.1 39 WX-203 32.0.35 15 47 1 9.9 8.6 7.6 47 WX-205 34.0 1.00 22 30 1 1 4 10.5 9.1 8.0 57 WX-250 44.0.77 22 36 1 1 4 13.6 11.8 10.4 65 WX-251 62.0.55 22 47 1 1 4 19.2 16.6 14.6 87 WX-255 81.0.41 22 57 1 1 4 25.0 21.7 19.1 109 WX-252 86.0.39 22 62 1 1 4 26.6 23.0 20.3 107 WX-302 86.0.54 26 47 1 1 4 26.6 23.0 20.3 106 WX-350 119.0.39 26 62 1 1 4 36.8 31.9 28.1 146 DuraBase : Available on all models except WX-252. Use suffix D. Pro Access : Available on all models except WX-201, WX-252 and DuraBase models. Use suffix PA. Tan and Gray: Available on all models except WX-252. Use suffix T or G. Model Underground Models Diameter System (NPTF) System Drawdown (gallons) 30/50 40/60 50/70 WX-200UG 14.0.81 15 22 1 4.3 3.8 3.3 22 WX-202UG 20.0.57 15 30 1 6.2 5.4 4.7 30 WX-250UG 44.0.77 22 33 1 1 4 13.6 11.8 10.4 60 WX-251UG 62.0.55 22 44 1 1 4 19.2 16.6 14.6 83 6 Note: System Drawdown can be affected by various ambient and system conditions, including temperature and pressure.

Model Specifications & Sizing Wall Hung Model for VFD Systems Model Length Dimensions Width System System Drawdown (gallons) (NPTM) 30/50 40/60 50/70 WX-102VFD 4.4.55 15 11 12 3 4 1.4 1.2 1.0 13 Includes Universal VFD Control Mounting Bracket. Model Pump Stand Models Length Dimensions Width System System Drawdown (gallons) (NPTM) 30/50 40/60 50/70 WX-102PS 4.4.55 15 11 12 3 4 1.4 1.2 1.0 13 WX-105PS 5.3.80 18 11 12 3 4 1.6 1.4 1.3 15 WX-110PS 7.4.56 23 11 12 3 4 2.3 2.0 1.8 18 WX-200PS 14.0.81 22 15 16 1 4.3 3.8 3.3 29 WX-202PS 20.0.57 30 15 16 1 6.2 5.4 4.7 35 WX-202H 20.0.57 30 15 16 1 6.2 5.4 4.7 33 All Well-X-Trol Well s feature: Stainless Steel System. Maximum Working Pressure: 150 psig. Maximum Operating Temperature: 200 F. y Pre-charge: 38 psig. Pump Discharge Rate (Approx. GPM) Pumps Up To 3/4 hp & 1 Minute Run Time ESP Sizing Table Pumps Over 3/4 hp & 2 Minute Run Time 30/50 PSIG 40/60 PSIG 50/70 PSIG 30/50 PSIG 40/60 PSIG 50/70 PSIG 5 WX-202 WX-202 WX-202 WX-205 WX-205 WX-250 7 WX-202XL WX-203 WX-203 WX-250 WX-251 WX-251 10 WX-205 WX-205 WX-250 WX-251 WX-255 WX-302 12 WX-250 WX-250 WX-251 WX-255 WX-255 WX-350 15 WX-250 WX-251 WX-251 WX-302 WX-350 WX-350 20 WX-251 WX-255 WX-302 WX-350 WX-255 (2) WX-302 (2) 25 WX-255 WX-302 WX-350 WX-255 (2) WX-302 (2) WX-350 (2) 30 WX-302 WX-350 WX-350 WX-302 (2) WX-350 (2) WX-302 (3) 35 WX-350 WX-350 WX-255 (2) WX-350 (2) WX-350 (2) WX-350 (3) 40 WX-350 WX-255 (2) WX-302 (2) WX-350 (2) WX-302 (3) WX-350 (3) The Effective System Protection (ESP) sizing procedure covers modern residential water-use habits, heavy demands and the general increase in water use that has occurred in recent years. ESP sizing is designed to reduce system wear and lower energy consumption by keeping pump starts to a minimum. Variable Frequency Drive (VFD) Sizing Table Pump Discharge Rate (Approx. GPM) Pump Motor Horsepower size at least 20% of pump GPM rounded to next size up. 1/2, 3/4 & 1 hp Larger pumps = Move up additional tank size. 1 1/2 to 2 hp 7 WX-102VFD WX-103 10 WX-102VFD WX-103 12 WX-102VFD WX-103 15 WX-103 WX-104 20 WX-103 WX-104 25 WX-104 WX-202 30 WX-104 WX-202 Sizing chart is to be used in the absence of the VFD manufacturer s tank size recommendation. Selections include additional buffer capacity to minimize pressure fluctuation. A larger tank is always a system enhancement. pre-charge should be set according to drive manufacturer. Larger = Fewer Cycles = Longer and Pump Life. 7

Well Above The Rest Not all well tanks are created equal and we can prove it. The s on Tour mobile education center is traveling throughout the United States and Canada demonstrating the very real differences that make Well-X-Trol Well Above The Rest. All models are Amtrol Rewards eligible. Visit amtrolrewards.com s on Tour in front of the Amtrol Education Center. 1400 Division Road, West Warwick, RI USA 02893 T: 401.884.6300 www.amtrol.com 2017 AMTROL Inc. MC 10188 (03/17)