A calculation model for Trombe walls and its use as a passive cooling technique

Similar documents
EXPERIMENTAL INVESTIGATION INTO THE BUOYANCY DRIVEN CONVECTION IN PASSIVE SOLAR HEATING FACADES

Transient Performance Analysis of a Model Building Integrated with a Trombe-Wall

BUILDING DESIGN AND THERMAL INERTIA: WHEN, WHY, WHERE

Observation of Liquid-filled Window without Presence of Liquid in Test Chamber

MODELLING BUOYANCY INDUCED FLOWS OF PASSIVE COOLING SYSTEMS Pedro Correia da Silva 1, Vítor Leal 1 and J. Correia da Silva 2

Mathematical Modeling of Basic Parts of Heating Systems with Alternative Power Sources

DESIGN AND USE OF RADIANT BARRIERS AS THERMAL INSULATION FOR HIGH INERTIA HOUSES IN TROPICAL CONDITIONS A CASE STUDY

Numerical Investigation of the Air Flow in a Novel PV-Trombe Wall Based on CFD Method

Performance Evaluation of Natural Ventilation Devices to Improve Thermal Comfort of a Computer Lab of University Building Using CFD as a Tool

STEADY STATE AND DYNAMIC THERMOPHYSICAL PARAMETERS OF TRANSPARENT BUILDING COMPONENTS

Chapter 7. Passive Solar Contents

THERMAL MASS IMPACT ON ENERGY PERFORMANCE OF A LOW, MEDIUM, AND HEAVY MASS BUILDING IN BELGRADE

Optimal design for a dual-airflow window for different climate regions in China

THERMAL MASS IMPACT ON ENERGY PERFORMANCE OF A LOW, MEDIUM AND HEAVY MASS BUILDING IN BELGRADE

Feasibility study of a roof top Solar room heater

COMPARISON OF THERMAL PERFORMANCE OF DIFFERENT WALL STRUCTURES

Shading effects on the winter thermal performance of the Trombe wall air gap: An experimental study in Dalian

COMPARATIVE SUMMER THERMAL AND COOLING LOAD PERFORMANCE OF NATURAL VENTILATION OF CAVITY ROOF UNDER THREE DIFFERENT CLIMATE ZONES

Targeting and Design of Evacuated-Tube Solar Collector Networks

Exergy analysis of a flat plate solar collector

Solar Flat Plate Thermal Collector

Effects of external window form on residential building energy consumption

Numerical Study on the Effect of Insulation Materials on the Single Zone building Performance

Numerical Modeling of Buoyancy-driven Natural Ventilation in a Simple Three Storey Atrium Building

Solar gains in the glazing systems with sun-shading

A Case Study on the Daylighting and Thermal Effects of Fixed and Motorized Light Louvers

Collector Efficiency of the Double-Pass Solar Air Collectors with Fins

ENERGY SAVING IN BUILDING USING PCM IN WINDOWS

HEADQUARTERS OF THE COMISIÓN NACIONAL DEL MERCADO DE VALORES. DOUBLE FAÇADE SIMULATION STUDY. Barcelona, Spain.

SIMULATION OF BUILDING WITH TRANSPARENTLY INSULATED WALLS IN EDIRNE/TÜRKIYE

Energy Consumption Measurement of Energy-saving Buildings and Analysis of Simulation Example

Performance Analysis for Natural Draught Cooling Tower & Chimney through Numerical Simulation

The effect of shading design and control on building cooling demand

Potential of natural ventilation in shopping centres

EFFECT OF AIR GAP ON PERFORMANCE ENHANCEMENT OF BUILDING ASSISTED WITH PHOTO VOLTAIC SYSTEMS

Q-Air detailed physical properties

Demonstration of Load Shifting and Peak Load Reduction with Control of Building Thermal Mass

Numerical Investigation of Air Flow and Temperature Distribution in a Trombe Wall System: A CFD Study

FAST EVALUATION OF SUSTAINABLE HEATING AND COOLING STRATEGIES FOR SOLAR HOMES WITH INTEGRATED ENERGY AND CFD MODELING

Perception of Thermal Comfort for Naturally Ventilated High School Classrooms in San Rafael, CA

THE USE OF A SIMULATION TOOL IN ORDER TO OBTAIN THE THERMAL PERFORMANCE OF PASSIVE SOLAR HOUSES IN PORTUGAL

SMART CONTROL FOR NATURAL VENTILATION HOUSE

Sustainable Building Façade and Advanced Fenestration Systems

Applied Thermal Engineering

BIPV/T versus BIPV/T-PCM: A numerical investigation of advanced system integrated into SolarXXI building façade

CFD Modelling and Analysis of Different Plate Heat Exchangers

Description and Visual Representation of Most Promising Markets

PASSIVE SOLAR WALL INTEGRATED WITH A LATENT STORAGE LAYER

Thermal Control in Buildings by John Straube (updated )

Thermal performance of concrete wall panel with advanced coating materials: a sustainable design

Potentials of the new design concepts of district heating and cooling toward integration with renewable energy sources

CAE 331/513 Building Science Fall 2017

Evaluation on the Performances of a Ventilated and Non-ventilated Cavity behind a BIPV: Modelling and Experimental Monitoring

JOTUN Cool Shades. Impact of the TSR Value on the Users Comfort and the Energy Performance of Buildings. ai³ Werner Jager

Pearl River Tower. Guangzhou, China. AEI Professional Project Awards January 2014 PHOTO CREDIT: TIM GRIFFITH

Solar cooling design: a case study

MEASUREMENTS OF RADON ENTRY PARAMETERS IN THE BUILDINGS

Solar distillation is one

Dynamic simulation of buildings: Problems and solutions Università degli Studi di Trento

Modelling Analysis of Thermal Performance of Internal Shading Devices for a Commercial Atrium Building in Tropical Climates

Thermal Accumulation in Solar Systems for Hot Water Abstract 1. Introduction

Assessing thermal comfort of dwellings in summer using EnergyPlus

Numerical Simulation of the Thermal Performance of a Dry Storage Cask for Spent Nuclear Fuel Chi-Ming Lai, University Distinguished Professor Departme

Smoke Control using a Double-skin Facade

HVAC INTEGRATED CONTROL FOR ENERGY SAVING AND COMFORT ENHANCEMENT vahid Vakiloroaya

CFD tools and lower order modeling for regenerative chambers with gas recirculation system

Figure 1: Uncovered and covered PVT collectors

BASIC EUROPEAN GLAZED COLLECTORS & SOLAR DOMESTIC

EFFECTS OF WEATHERS AND INDOOR TEMPERATURES ON PERFORMANCE OF ENERGY RECOVERY VENTILATOR. Yanping Zhou, Jingyi Wu, Ruzhu Wang

Thermal comfort conditions in outdoor spaces

Ventilated Illuminating Wall (VIW): Natural ventilation and daylight experimental analysis on a 1:1 prototype scale model

Thermal comfort study of naturally ventilated office

A STUDY ON PERFORMANCE OF SOLAR SEAWATER DISTILLATION SYSTEM WITH AN AUXILIARY HEAT SOURCE FROM SOLAR COLLECTOR

SOLAR ENERGY Utilization

GENERALIZED CRITERIA OF ENERGY PERFORMANCE EVALUATION IN EARLY DESIGN STAGES OF NEARLY ZERO-ENERGY BUILDINGS

MODELLING THE ENERGY PERFORMANCE OF NIGHT-TIME VENTILATION USING THE QUASI-STEADY STATE CALCULATION METHOD

EXPERIMENTAL INVESTIGATION OF SOLAR AIR COLLECTOR BY COMPARING GLASS WOOL AND FOAM AS AN INSULATION MATERIAL

Investigating two configurations of a heat exchanger in an Indirect Heating Integrated Collector Storage Solar Water Heating System (IHICSSWHS)

Heat Transfer Analysis Collector

Experimental Analysis of Heat Transfer Enhancement Using Fins in Pin Fin Apparatus

Performance Analysis of Shell and Tube Heat Exchanger Using Miscible System

Thermal Analysis of Solar Flat Plate Collector

ANALYSIS AND MITIGATION OF THERMAL EFFECTS ON A LARGE FACADE-MOUNTED PV ARRAY

Lecture 3: Utilization of Passive Solar Technology

THEORETICAL RESEARCH REGARDING HEAT TRANSFER BETWEEN GREENHOUSES AND ENVIRONMENT

2006 Building Science Press All rights of reproduction in any form reserved.

INTENT INtegrated Energy walls Test facility

Research and Development on Solar-Induced Ventilation

Investigating Two Configurations of a Heat Exchanger in an Indirect Heating Integrated Collector Storage Solar Water Heating System

A NEW POLYNOMIAL BASED MODEL FOR DETERMINING COOLING TOWER EVAPORATION WATER LOSS. Aaron Powers Johnson Controls, Inc.

Comparative Heating Performances of Ground Source and Air Source Heat. Pump Systems for Residential Buildings in Shanghai

ENERGY PERFORMANCE OF DIFFERENT TYPES OF DOUBLE SKIN FACADES IN VARIOUS CLIMATES

Solar Power. Technical Aspects and Environmental Impacts. 6 th March 2011 Sustainable Energy Options (UAU212F) - University of Iceland

GREEN AND COOL ROOFS URBAN HEAT ISLAND MITIGATION POTENTIAL IN EUROPEAN CLIMATES FOR OFFICE BUILDINGS UNDER FREE FLOATING CONDITIONS

ANSI/ASHRAE STANDARD , METHODS OF TESTING CHILLED BEAMS

Experimental Studies on Water based Photovoltaic Thermal Collector (PVT)

BUILDING INTEGRATED VENTILATION SYSTEMS MODELLING AND DESIGN CHALLENGES

Thermal comfort evaluation of natural ventilation mode: case study of a high-rise residential building

Impact of airtightness on the heat demand of passive houses in central European climate

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Transcription:

International Conference Passive and Low Energy Cooling 365 for the Built Environment, May 5, Santorini, Greece A calculation model for Trombe walls and its use as a passive cooling technique Á. Ruiz, J.M. Salmerón, F. Sánchez, R. González and S. Álvarez E S. Ingenieros, Grupo de Termotecnia, Avda. de los descubrimientos s/n, Sevilla, Spain ABSTRACT A low energy technique for heat removal from the interior of a building under summer conditions is the employ of natural ventilation. There are several ways to promote this ventilation. The use of Trombe walls to obtain this objective is studied in the present work, with the aid of a combined mathematicaldifferences finites model. This is a transient model developed to take into account the thermal inertia of the wall and that can be easily applicable to a particular Trombe wall to estimate its behaviour. Additionally, the influence on heat balance done by different elements of the wall, and its properties was studied in a parametric work. This was done for different climates in Spain, and the results were analyzed with a new variable defined as (degree-days difference). As a result of this parametric study, some guidelines of design were established in function of the climate conditions. 1. INTRODUCTION The interest in passive solar heating has been increased in the last years, mainly for economic and environmental reasons. One of the most studied elements for this purpose is the Trombe wall. Its use can be an effective alternative on the reduction of the energy consumption in zones where heating is much more important than the refrigeration. Nevertheless, in summer, the non wished effect of excessive heat gain can be presented through this element. This situation could be critic in those climates where summer is hot. In consequence, the Trombe wall utility must be carefully evaluated. To increase the possibility of use of Trombe walls in hot climates, this element can be operated in different modes in order to minimize conduction heat gains through the storage wall and to maximize heat removal from the interior by the ventilation. Figure 1 shows the three modes of operation considered. Mode (a) is useful to accumulate heat in the thermal mass of the storage wall if there is radiation falling. Mode (b) is used to remove energy from the storage wall in order to reduce the undesirable effect of heat conduction to the interior. Mode (c) uses the storage energy or the solar radiation falling to produce air ventilation. This mode is supposed to be working only if the exterior temperature is lower than interior.. MODEL DESCRIPTION The air temperature and air velocity in the channel were calculated in a simplified mathematical model. Heat transfer through storage wall was calculated with a differences Figure 1: Diagram of operating modes for a Trombe wall in summer (a) closed, (b) exterior to exterior flow, (c) interior to exterior flow.

366 International Conference Passive and Low Energy Cooling for the Built Environment, May 5, Santorini, Greece finites model..1 Air Temperature The air temperature in the layer, when this is in movement was calculated from Ec. 1. The schema of the model is showed in Figure. v A e Ta = Tp V H Tg L + Tw Tp = L hc V = Cp ρ T h c out ( Tout Tin) V ( ) = Tp Tp Tin exp H e v A (1) () (3) (4) ρ: average density of the air in the layer. Cp: air specific heat capacity. h c : average convective heat transfer coefficient in the layer, Ec.(5). Nu k = e (5) k: Thermal conductivity of air. Nu: Nusselt number. Ec.(6) (Sparrow and Azevedo, 1985). 1 Nu = ( / ) e H Ra 1 +.619(( e / H ) Ra) 1/ 4 1/ (6) Ra: Rayleigh number.. Air Velocity The pressure difference, taking into account that the air temperature is not uniform in the vertical direction can be calculated with Ec.(7): g M Patm H H e v A P = ) Ru Ti Tp V Tp [ ln( Tout) ln( Tin ] (7) P: Pressure difference or stack pressure, M: Molar weight of the air, P atm : Local atmospheric pressure, Ru: Universal gas constant. The air velocity is calculated from Ec.(8): v A P = Ae H ρ C1 + + f C Ain e Ae Aout 1/ (8) C 1 : Pressure loss coefficient at the inlet of the channel. f: friction factor for the channel. C : Pressure loss coefficient at the outlet of the channel. Ae: transversal area of the channel. Ain: inlet area. Aout: outlet area. For this work it has been assumed rectangular inlet and outlet, and in consequence C 1 =1.5, C =1., f=.56 (Chen et al., 3)..3 Heat transfer in the channel The heat transfer in the channel was calculated in a simplified model based on the electrothermal equivalent system shown in Figure 3. In the electrical system, knows values are: all heat transfer coefficients, all material properties, outdoor temperatures, incident solar radiation, and superficial temperature of the storage wall. Figure : Schematic model. Figure 3: Electrical equivalent system.

International Conference Passive and Low Energy Cooling 367 for the Built Environment, May 5, Santorini, Greece Ta I*gg*αw hr TgL h x1 x xn-1 xn K K1 K Kn- Kn-1 Kn 1 n-1 n hci n+1 Ti hri C1 C Figure 4: Electrical equivalent representation of the storage wall model..4 Heat transfer in the storage wall, and determination of superficial temperatures. The model used in an electrical equivalent representation a sequence of conductances and capacitances as is shown in Figure 4. On precedent paragraphs, isolated solutions were shown. To couple the whole system, an iterative process is necessary. 3. MODEL VALIDATION The model was validated with the numerical model presented for Guohui Gan (Gan, 1998), who found a good agreement with experimental results. The following figures (Figs. 5, 6 and 7) show the comparison between these two models for different parameters. From the presented figures it is clear that good agreement between two models is achieved for most cases. Principal difference is on air flow rate for wall heights over 3m. Cn-1 Cn Tri 6 6 Total solar irradiance <W/m²> Figure 5: Effect of solar irradiance on air flow rate. 45 35 5 15 5 1 3 4 5 Trombe Wall height (H) <m> Figure 6: Effect of Trombe wall height on air flow rate. 35 5 15 5..4.6.8 1 1. Storage wall thickness <m> Figure 7: Effect of storage wall thickness on air flow rate. 4. BEHAVIOUR OF TROMBE WALL UNDER SUMMER CONDITIONS Climates selected for simulation were mainly of cities near to the Mediterranean Sea and for the months of June, July and August. Indoor air temperature and equivalent radiant indoor temperature were assumed to be invariables during the time simulated with a value of 5ºC. Climatic data were simplified in two steps. The first step was to calculate two factors: the monthly degree-days over 5ºC and under 5ºC. The second step was to calculate the difference between the previous factors. By means of this simplification the climate is characterized in only one variable, defined as (degreeday difference) in Ec.9 = (DD over 5ºC)-(DD under 5ºC) (9) Two kinds of climates were defined: mild and hot. First ones are those with <- ºC and second ones are those with > ºC. The basic data of the Trombe wall model were: H=3m, e=.1m, C1=1.5, f=.56, C=1., simple glassing, storage wall thickness=.31 m, storage wall absortance=.8. 4.1 Operation Mode Influence As it was said in the introduction, simulations include three operation modes (Fig. 1). Also, three combinations of operation modes were performed. -. While there is solar radiation falling (direct, or diffuse), the Trombe wall will be operating in mode (a). In any other case will be operating in mode (c).

368 International Conference Passive and Low Energy Cooling for the Built Environment, May 5, Santorini, Greece -. While there is solar radiation falling (direct, or diffuse), the Trombe wall will be operating in mode (b). In any other case will be operating in mode (c). -. If there is solar radiation falling (direct, or diffuse), and the time is under 13 hour, the Trombe wall will be operating in mode (b). If the time is equal or over 13 hour, and there is solar radiation falling, the Trombe wall will be operating in mode (a). In any other case will be operating in mode (c). In Figure 8, the heat gains through the storage wall are shown for several climates. It is seen that the heat increases when the difference of degree days enlarges. It is seen also, that combination (A) allows the highest heat gains while in combination (B) the heat gains are the lowest. But the difference between tree lines is close and they are approximately parallels. Heat gain removal by the air is shown in Figure 9 for the tree operations combinations. It is seen that combination (A) is the most favorable to heat removal by air ventilation, but its advantage is reduced for hot climates. has a poor effect on heat 9 7 - - -3 - - - -1 - - Figure 8: Operation mode influence on heat gains through the storage wall. 9 removal, and it is maintained approximately constant for all the climates considered. The combination (C) is located between (A) and (B), but it is close to combination (B). The heat balance of the heat gains and heat removal is shown in Figure. As seen from the figure, is the combination (A) the most favorable for mild climates in summer, but for hot climates, combinations (A) and (B) are similar, being the combination (C) the worst, but with a short difference. For a very different wall (thinner wall and higher U-value), as the shown in Figure 11, the heat balance has approximately the same tendency, but for hot climates combination (C) shows and intermediate behaviour between combinations (A) and (B), being combination (B) the best for the hottest climates. 4. Glassing Influence Two glassing types were considered, simple and double. Figure 1, shows the heat balance for the Trombe Wall with simple and double glassing for two operation modes. It is seen that double glassing improves the Trombe wall behaviour for all the climates considered, but its advantage is higher for mild climates. 4.3 Insulation Influence and Wall thickness Inner insulation for the storage wall was considered. Figure 13 shows the heat gains through the storage wall for several climates. It is seen that for hot climates the advantageous of using insulation is greater than for mild climates. In Figure 14, the air heat remove is shown. It is seen that there is not big difference between them. Heat balance is shown in Figure 15. It is seen that for 4cm of thickness insulation an important 9 7 7 - - - -3 - - - -1 - - Figure 9: Operation mode influence on heat removal by the air ventilation. - -3 - - - -1 - - Figure : Operation mode influence on heat balance (gains-heat removal).

International Conference Passive and Low Energy Cooling 369 for the Built Environment, May 5, Santorini, Greece - - - - - (double_glazing) (double glazing) -3 - - - -1 - - Figure 1: Influence of simple and double glassing on monthly heat balance (gains-heat removal). Qin_wall - - - - cm cm 4 cm -3 - - - -1 - - Figure 13: Inner insulation influence on heat gains through the storage wall. - - - - cm cm 4 cm -3 - - - -1 - - Figure 14: Inner insulation influence on heat removal by the air ventilation. - - - cm cm 4 cm - -3 - - - -1 - - Figure 15: Inner insulation influence on heat balance (gains-heat removal). proportion of points are located under zero. 5. CONCLUSIONS Combinations of operation modes of a Trombe wall affect its thermal behaviour. This effect is more relevant on climates with mild summer. The most convenient combination for these mild climates is the combination (A). It seems to be valid for a wide range of thermal inertia and heat conductance of the storage wall. For hot climates, the combinations of operation modes are not as relevant as for mild climates, but the thermal mass and thermal resistance of the storage wall, could be a decisive variable to define the best combination of operation modes. can be more favourable if the thermal inertia and thermal resistance of the wall are higher than for a wall whit low value of thermal mass and resistance. For this last case, a combination (B) could be more adequate. Double glassing improves Trombe wall behaviour, but its benefit is short in hot climates. Inner insulation shows a strong benefit on Trombe wall behaviour. It is motivated by the fact that conduction heat gains are strongly diminished. For a Trombe wall under summer conditions and constant indoor temperature, the conduction heat gains and air heat remove, are approximately linear with (degree-days difference), defined in Ec. (9). REFERENCES Chen, Z.D, P. Bandopadhayay, J. Halldorsson, C. Byrjalsen, P. Heiselberg and Y. Li, 3. An experimental investigation of a solar chimney model with uniform wall heat flux, Building and Environment, 38:893-96. Gan, G., 1998. A parametric study of Trombe walls for passive cooling of buildings, Energy and Buildings, 7:37-43 Incropera, F.P. and P.D. David, 1996. Fundamentals of heat and mass transfer. New York: John Wiley & Sons. Sparrow, E.M. and L.F.A. Azevedo, 1985. Verticalchannel natural convection spanning between the fully-developed limit and the single-plate boundarylayer limit, International Journal of Heat and Mass Transfer, 8:1847-1857.