Permanent Pressure Loss Comparison Among Various Flowmeter Technologies

Similar documents
CUSTODY TRANSFER FLOW MEASUREMENT WITH NEW TECHNOLOGIES. Stephen A. Ifft McCrometer Inc. Hemet, California, USA

Effects of Pipe Wall Offsets on Differential Pressure Meter Accuracy

COIN. Flow Meters. Segmented Wedge. Your First Choice in Intelligent Flow Management...

Comparison of Four Gas Measurement Technologies Orifice/Turbine/Coriolis & Ultrasonic

Universities of Leeds, Sheffield and York

February 5, 2013 Roy Ratcliffe, President RM Controls, Inc.

Pipe Flow Hydraulics

ABB Measurement & Analytics Flowmeter technologies

Gilflo flowmeters. for steam, liquids and gases

Gilflo ILVA flowmeters for steam, liquids and gases

SRP Fluids Analysis: Agua Fria Flow Measurement

Engineering Standard. Saudi Aramco DeskTop Standards

WHITE PAPER A New Approach to Accurate Water Flow Measurement - The Study of the FPI Mag Accuracy

Orifice Plates. All types of Orifice Plates and. relative products

ISO INTERNATIONAL STANDARD

Journal of Mechanical Science and Technology 25 (8) (2011) 1961~ DOI /s

Utility Flow Metering for Steam and Heated/Chilled Water: A Tutorial. Richard Gruskos Flow Products Manager Kessler Ellis Products

MEASUREMENT OF AIRFLOW

The Paradigm Case Method of Flowmeter Selection

Field Experiences with V Cone Technology. McCrometer Inc. Hemet, CA.

The World Market for Primary Elements, 2 nd Edition Overview

Flow Conditioning for Irrigation Propeller Meters

Model 140MX Flowmeter Functional Overview

PRODUCT INFORMATION. Model 140MX Flowmeter Functional Overview. PI 14-1 Rev: 1 March 2002

introduced before the end of World War II. 2 They are less the focus of new product development than new-technology

VENTURI FLOWMETERS. Your First Choice in Intelligent Flow Management...

TVA Target Variable Area Flowmeter

Numerical analysis of eccentric orifice plate using ANSYS Fluent software

VERIS Accelabar. Superior Flow Measurement Accuracy

FLUID MECHANICS PROF. DR. METİN GÜNER COMPILER

RUNYI GROUP. Main Features. STLU Vortex Flow Meter

Flow Test Data Book and Flow Handbook for 405 Compact Orifice Series and 1595 Conditioning Orifice Plate

Erosion Effects in Flowmeters

DIVA flowmeter. for saturated steam flow measurement

An Intercomparison between NEL, CMS/ITRI, SIPAI, KRISS, IPT and CENAM using a 200 mm Twin Orifice Plate Package in Water

Troubleshooting Piping Systems

Differential Pressure Flow Metering: Problem Solver for Chemical Processing Industry (CPI) Applications. IND-WP EN-01 (July 2018) White Paper

USKON AKIŞKAN KONTROL SİSTEMLERİ SANAYİ VE TİCARET LTD. ŞTİ.

Custom Engineered Flow Meters. Differential Pressure Products

True Performance in Flow Measurement. Verabar. Velocity Averaging Flow Sensors

The World Market for Steam Flow Measurement

APlus-QMC LLC. Catalog 2017

Welcome to Flow Control - Solutions for the Fluid Handling Industry

Field Experiences with V -Cone Technology. Philip A. Lawrence McCrometer Inc O&G Office Houston TX.

EEN-E1040 Measurement and Control of Energy Systems / v. 08 / TP / Flow measurement. Instructions

s the costs of fuels and consumables to rise, the ability to accurately measure the amount used in a process becomes significant

TVA flowmeter. for saturated steam flow measurement

COLORADO ENGINEERING. CERTIFICATE OF CALIBRATION Traceable to the NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY

Appendix T MRWPCA GWR Discharge Dilution Analysis

Flow Conditioning Why, What, When and Where. Gas Flow Conditioning Why, What, When and Where

Setting The Standard

Venturi Tubes in Wet Gas Improved Models for the Over- Reading and the Pressure-Loss Ratio Method

Gary Fiselier Measurement Lead, EnCana Corporation

KURZ Thermal mass flowmeters aimed to improve combustion efficiency. AUTOMATION INSTRUMENTATION SUMMIT July 4th 2018 Gianantonio Favalessa

T.E. (Mech., Mech. S/W) (Semester II) Examination, 2011 TURBOMACHINES (New) (2008 Pattern)

PORTABLE, AUTOMATIC, ISOKINETIC AEROSOL / DUST SAMPLER MEASUREMENT CIRCUIT IN STACK VERSION

Flow Meter Calibration

The Unique Accelabar Flow Meter

Naturally Entraining Solid Particle Injector

Flow measurement: some problems to solve and some surprises. Dr Michael Reader-Harris, NEL

Flowmetering Choosing the right flowmeters to achieve targeted energy savings

Master Meter Testing at Water Plants and Pump Stations. Jeff Cruickshank, PE

A M E M B E R O F T H E K E N D A L L G R O U P

VLM10 In-line Vortex Mass Flow Meter

VENTURI FLOW METER CALIBRATIONS SERIAL NUMBERS: , , , Prepared for. Imperial Flange and Fitting.

Steam Meters Selection and Installation

DZR Commissioning Set. Flow Data and Installation Instructions

Contour K5 Technical Information

Contents. 1 Gas Measurement Fundamentals Head Meters Turbine Meters Other Meters Orifice Meters... 5.

ORIFICE MTERE BASIC SELECTION & DESIGN CONSIDERATIONS. All rights reserved to thepetrostreet.com

Fluid Flow Conditioning. August 2015

WELLHEAD METERING USING V-CONE TECHNOLOGY

ANALYSIS OF APPLICABILITY OF FLOW AVERAGING PITOT TUBES IN THE AREAS OF FLOW DISTURBANCE

Laboratory Testing of Safety Relief Valves

Effects of Geometrical Parameters on Performance Characteristics of Venturimeter

Insertion Flow Meters. The only hot tap Full Profile Insertion Flow Meter.

ASME PTC Flow Measurement

Water-side Systems. Ir. Dr. Sam C. M. Hui Faculty of Science and Technology

OTCO 12/11/13 Water Audits Meter Testing & Leaks

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S)

Presentation Overview

Industrial Flowmeters

Stress Analysis of Fixed Site Series 6000 Antennas

Upstream Production Measurement Solutions

CONE JET SPRAY NOZZLE type C

Determination of the filtration performance of air filter CD408/34.5/171 according to EN 779:2002

Fiscal and Allocation Metering

Because you can t manage what you don t measure usa.siemens.com/hvacr

SAM IL INDUSTRY CO.,LTD. IN THIS CHAPTER - 5

EFFECTS OF SHEAR AND CAVITATION ON PARTICLE AGGLOMERATION DURING HANDLING OF CMP SLURRIES CONTAINING SILICA, ALUMINA, AND CERIA PARTICLES

f=sr.v/d Thereinto f----fre quency of Karman Vortex shedding Sr----Strouhal number v----velocity d----width of column object

Micro Motion Technical Overview and Specification Summary

HIGH PERFORMANCE FLOW CONDITIONERS Michael P. Saunders Savant Measurement Corporation USA

Determining Optimal Discharge and Optimal Penstock Diameter in Water Turbines

flow measurement Methods

MASS TRANSFER AND HYDRAULIC DETAILS ON INTALOX PhD PACKING

Performance of an Air-Assist Nozzle Using Heated Air

Introduction. Objective

F Series Flow Meter F300. User Manual

General Guidelines on Drop Size Measurement Techniques and Terminology

Transcription:

Permanent Pressure Loss Comparison Among Various Flowmeter Technologies by Stephen A. Ifft McCrometer Hemet, California, USA Abstract This paper explores the issue of permanent pressure loss through various types of flow metering technologies. Of particular interest is the. The flowmeter is a differential pressure device produced by McCrometer, Hemet, California, USA. By design, the measures differential pressure created by a cone positioned in the center of the pipe. The open area through which the fluid passes is stretched over the edge of the cone. This annular space appears to constrict flow dramatically compared to other metering technologies. This paper compares the permanent pressure loss among meters in a typical application. Introduction The is a patented flowmeter made by McCrometer. With its unique geometry, the creates a differential pressure signal that is proportional to the square of the flowrate. This differential pressure signal is then measured by a secondary device that converts the analog pressure signal to an electronic signal, usually a standard 4-20 ma current signal. The electronic signal can then be used to calculate flowrate, mass rate, etc. using tertiary devices. One typical question regarding the is the amount of permanent pressure loss to be expected through the meter in the application. On first look, the cone appears to occupy an inordinate amount of space in the pipeline, and thus constrict the flow greatly. In reality, the cone restricts the flow very little. Several factors contribute to allowing the to measure flowrate very accurately without significant permanent pressure loss. Permanent Pressure Loss Comparison One method to compare differential pressure meters is by the beta ratio. The beta ratio is the ratio of the smallest open area to the largest open area in the meter. In traditional differential pressure meters, this is usually the ratio of the diameter of the constriction to the diameter of the pipe. This is identical to the ratio of the areas mentioned earlier. s also have beta ratios that share the same area definition. Since the does not have a central opening, the beta ratio is calculated in a slightly different manner. See. figure 1. If a meter has a beta ratio of, for example, 0.65, this means that 42% of the pipe area is still open at the largest constriction (0.65 x 0.65 = 0.42). This applies to all differential pressure flowmeters, including the. Page 1 of 8

A typical method to measure the permanent pressure loss in a differential pressure flowmeter is to state a percentage of the differential pressure created at a given flowrate. For example, a differential pressure meter may state a 50% permanent pressure loss of differential pressure created. If the maximum differential pressure created by the meter is 10 kpa, the permanent pressure loss at that flowrate is 5 kpa. If the flow decreased and the differential pressure becomes smaller, the permanent pressure loss will become smaller. The percentage of differential pressure permanently lost can be graphed as a relationship of beta ratio. See figure 2. The is positioned between the orifice and the nozzle curves. This, however, is not a true comparison between the permanent pressure loss expected through the meters because the requires less differential pressure to remain accurate and repeatable. This is possible because of the stable and controlled differential pressure signal created by the cone. A true comparison would be to compare the actual permanent pressure loss expected through various meters for a given application. Application Comparison An application was chosen to compare the permanent pressure loss through the following meters: 1. based on information from McCrometer 2. Plate 3. Flow 4. Venturi with 15 o exit angle 5. Venturi with 7 o exit angle 6. Turbine 7. Vortex based on information from Miller 1 8. Coriolis 9. Vortex based on information from Foxboro Co. 10. Coriolis based on information from MicroMotion Co. The application parameters were as follows: Application Information: Nominal Line Size: 3 inch Fluid: Water Temperature: 15 o C Pressure: 5 barg Density: 999.387 kg/m 3 Viscosity: 1.059 cp Flowrate: 1145 LPM Meter Sizing Page 2 of 8

Each differential pressure meter was sized according to standard specifications from McCrometer, Miller 1 and ISO 5167 2. The following chart shows specifics for each differential pressure meter: Venturi Beta ratio: 0.85 0.75 0.7 0.699 Max. DP (kpa): 12.3 45.8 24.6 24.6 Cf (Cd): 0.754 0.6 0.99 0.995 The has a recommended differential pressure (12.3 kpa) that is half what is recommended for all other differential pressure meters (24.6 kpa). The orifice was sized with the largest suggested beta ratio to keep the differential pressure as low as possible. At the largest beta ratio, the differential pressure created exceeded the recommended by almost twice. All other meters were selected according to line size alone. Standard meter specifications were used for the turbine and vortex. Other specific meters were selected based on manufacturer s recommendations and the following model numbers were used: MicroMotion Coriolis I/A Series E83 CMF300M In all cases the line size remained 3 diameter nominal. Results By comparing permanent pressure loss for a given application, an accurate comparison can be drawn between metering technologies. See figure 3 for a graphical representation of permanent pressure loss through these meters over a 10:1 flow turndown. See figure 4 for a graph of maximum loss through each meter at maximum flowrate. MicroMotion data appears only in figure 4 due to lack of turndown information from the manufacturer. To summarize, the meters ranked in the following order according to permanent pressure loss: 1. Venturi with 7 o exit angle 2. 3. Venturi with 15 o exit angle 4. Flow 5. Vortex 6. Turbine 7. 8. Plate 9. MicroMotion Coriolis 10. Page 3 of 8

Further Results A similar comparison was completed on a 2 line size to compare the effect of line size under generally similar conditions. The ranking changed slightly: 1. Venturi with 7 o exit angle 2. 3. Venturi with 15 o exit angle 4. Flow 5. Vortex 6. Turbine 7. 8. Plate 9. 10. MicroMotion Coriolis See figures 5 and 6 for graphical comparisons. Page 4 of 8

Figure 1 Permanent Pressure Loss Differential Pressure Meters 1 0.8 % of DP 0.6 0.4 0.2 0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 Beta Ratio Venturi 15 Venturi 7 Data from R. W. Miller "Flow Measurement Engineering Handbook" Second Edition, McGraw-Hill, 1989. Figure 2 Page 5 of 8

Permanent Pressure Loss Comparison 3" 1145 LPM Permanent Pressure Loss (kpa) 10.0 1.0 0.1 Turbine Vortex Venturi 15 o Venturi 7 o 100 1000 Flowrate (LPM) Data from R.W. Miller, Flow Measurement Engineering Handbook, Second Edition, McGraw-Hill, 1989, unless otherwise noted by company name. Figure 3 35 Permanent Pressure Loss Comparison Maximum Loss: 3" 1145 LPM Permanent Pressure Loss (kpa) 30 25 20 15 10 5 Venturi 15 Venturi 7 Turbine Vortex MicroMotion Coriolis 0 Meter Types Data from R. W. Miller "Flow Measurement Engineering Handbook" Second Edition, McGraw-Hill, 1989, unless otherwise noted by company name. Figure 4 Page 6 of 8

Permanent Pressure Loss (kpa) 100.00 10.00 1.00 0.10 Permanent Pressure Loss Comparison 2" 527 LPM Turbine Vortex Venturi 15 o Venturi 7 o 0.01 100 Flowrate (LPM) Data from R.W. Miller, Flow Measurement Engineering Handbook, Second Edition, McGraw-Hill, 1989, unless otherwise noted by company name. Figure 5 Permanent Pressure Loss Comparison Maximum Loss: 2" 527 LPM 50 MicroMotion Coriolis Permanent Pressure Loss (kpa) 40 30 20 10 Turbine Vortex Venturi 15 Venturi 7 0 Meter Types Data from R. W. Miller "Flow Measurement Engineering Handbook" Second Edition, McGraw-Hill, 1989, unless otherwise noted by company name. Figure 6 Page 7 of 8

References 1. Miller, R. W., Flow Measurement Engineering Handbook, Second Edition, McGraw-Hill, 1989. 2. International Standard ISO 5167, Measurement of fluid flow by means of orifice plates, nozzles and venturi tubes inserted in circular cross-section conduits running full., Ref. No. ISO-5167-1980 (E). Page 8 of 8