Research on Ground Source Heat Pump Design

Similar documents
Investigation on A Ground Source Heat Pump System Integrated With Renewable Sources

Operation of Cool Thermal Energy Storage to Increase Renewable Energy Utilization

Opportunities and Limitations of Building Precooling

Optimal Design for a Hybrid Ground-Source Heat Pump

Performance Mapping for Variable Ductless Heat Pump Systems in Heating, Cooling and Defrost Operation

Application of Near-Optimal Tower Control and Free Cooling on the Condenser Water Side for Optimization of Central Cooling Systems

Performance Evaluation under the Actual Operation Condition of a Ground Source Multiheat Pump System

Reducing Operating Costs with Optimal Maintenance Scheduling

Thermal Performances Of Three Types Of Ground Heat Exchangers In Short-Time Period Of Operation

Introduction to Geothermal Comfort Systems in INDIA

DOE Webinar Residential Geothermal Heat Pump Retrofits

Solar-Assisted Space Heating of a Highly Insulated Energy Efficient House

Assessing the Potential for Reduction in Peak Residential Electrical Loads Using a Heat Pump and Thermal Storage Systems

Utilizing Heat Dump Capacity of a Small Pond Attached to Infloor Slab of a Net-Zero Energy House

Performance enhancement of a photovoltaic thermal (PVT) and ground-source heat pump system

Low-Grade Waste Heat Recovery for Power Production using an Absorption-Rankine Cycle

geoexchange as an alternative energy source DESIGN APPROACHES

SIMULATION AND MODEL CALIBRATION OF A LARGE-SCALE SOLAR SEASONAL STORAGE SYSTEM

An Optimal Maintenance Scheduler

04/04/2012. Inc. By: Skanska. Image. New. Castle, DEE

NORTH AMERICAN MONITORING OF A HOTEL WITH ROOM SIZE GSHPS

SIMULATION MODEL IN TRNSYS OF A SOLAR HOUSE FROM BRAŞOV, ROMANIA

Conversion Factors for Comparing the Performance of Variable Refrigerant Flow Systems

Combination of solar collectors and ground-source heat pump for small buildings

Ground Source Heat Pumps

Introduction to Geothermal Comfort Systems in INDIA

*Corresponding authors. Tel.: x415, address: (N. Zhu)

White Paper. Geothermal Heating and Cooling

GEOTHERMAL HEAT PUMPS CONFIGURATIONS/INSTALLATION

Ground Source Heat Pump System Design and Case Studies

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

ENERGY SAVINGS, SIMULATIONS AND ECONOMIC ANALYSIS OF A GROUND SOURCE HEAT PUMP WITH VERTICAL BOREHOLE HEAT EXCHANGERS FOR A BELGIAN OFFICE BUILDING

District GeoExchange Systems & Waste Heat Recovery

Using Simulation Model to Reduce System Design Time and Cost

An Analysis on Cost Reduction Potential of Vertical Bore Ground Heat Exchangers Used for Ground Source Heat Pump Systems

Secondary Loop System for Automotiv HVAC Units Under Different Climatic Conditions

SOLAR HEAT INJECTION INTO BOREHOLES. Case Postale 6079, succursale «centre-ville», Montréal, Québec, Canada

The correct citation for this paper is:

1 INTRODUCTION. Keywords: ground source heat pump; energy pile; geothermal; geophysics; ground temperature

International Forum on Energy, Environment Science and Materials (IFEESM 2015)

The Role of Thermal Potential in Enhancing Energy Efficiency / Productivity

Economic Model Predictive Control for Variable Refrigerant Systems

DIRECTIONAL-BORE GROUND SOURCE HEAT PUMP FIELD REPORT

Limitations of Using Uniform Heat Flux Assumptions in Sizing Vertical Borehole Heat Exchanger Fields

Recent U. S. R&D results from IEA HPP Annex 41

Geothermal Heat Pump Systems Metropolitan Washington Council of Governments Built Environment and Energy Advisory Committee May 19, 2016

Simulations of a New Double U-tube Borehole Configuration with Solar Heat Injection and Ground Freezing

The Benefit of Variable-Speed Turbine Operation for Low Temperature Thermal Energy Power Recovery

Performance Comparison of Air-source Heat Pumps Using Economizer Vapor Injection and Internal Heat Exchanger in Cold Regions

Residential Swimming Pool Heating with Geothermal Heat Pump Systems

SIMULATION AND OPTIMIZATION OF GROUND SOURCE HEAT PUMP SYSTEMS

The Effects of Set-Points and Dead-Bands of the HVAC System on the Energy Consumption and Occupant Thermal Comfort

Available online at ScienceDirect. Energy Procedia 78 (2015 )

ABSTRACT INTRODUCTION

Characteristics of Energy Consumption by building type of a U.S. Navy Installation in Hot and Humid Climate

Energy Simulation And Optimized Retrofit Practices Applied To A Real Dwelling

Welcome Everyone. Not Quite this kind! Geothermal Heat Pumps are a indirect solar heating system! Introduction to Geothermal

THE GEOTHERMAL ADVANTAGE

Highlights of the California GeoExchange Project

Performance Evaluation of a Passive Chilled Beam System and Comparison with a Conventional Air System

Other Names for Ground Loop Systems

Experimental Study of a CO2 Thermal Battery for Simultaneous Cooling and Heating Applications

geothermal Commercial heating and cooling system design

EXPERIMENT FOR VERIFICATION OF GROUND SOURCE HEAT PUMP USING THE DIRECT EXPANSION METHOD

Geothermal Heating & Cooling in Health Care Applications

The basic elements of the system include: Buried loops of piping (the ground loop); A biodegradable liquid antifreeze;

Methodology of Modeling and Comparing the Use of Direct Air-Cooling for a Supercritical Carbon Dioxide Brayton Cycle and a Steam Rankine Cycle

Annual Performance Of A Solar Assisted Heat Pump Using Ice Slurry As A Latent Storage Material

ABSTRACT INTRODUCTION

Improving the Energy Performance of HVAC Systems in Operating Theatres by Using Heat Recovery Devices

Chapter Six{ TC "Chapter Six" \l 1 } System Simulation

Secondary loop chilled water in super high-rise

CLOSED-LOOP HEAT EXCHANGER FOR GROUND COUPLED HEAT PUMPS

Application Of Oil Flooded Compression With Regeneration To A Packaged Heat Pump System

Influencing Factors on Ground Heat Balance of GSHP System Xiaohong Zhang1, a *, Zehua Liu2,b, Chao Zhang3,c and Long Ma4,d

EVALUATION OF GROUND COUPLED HEAT PUMPS FOR THE STATE OF WISCONSIN

Multi-Variable Optimisation Of Wet Vapour Organic Rankine Cycles With Twin-Screw Expanders

The American Council for an Energy-Efficient Economy Emerging Technologies Report. Residential Ground-Source Heat Pumps July, 2007

GEO-HEAT CENTER EXECUTIVE SUMMARY

Secondary loop chilled water in super high-rise

Influence Of Building Zoning On Annual Energy Demand

Geothermal Heat Pump Systems Being Green by using the Ground

DOE Task 99-4 Extension of Design and Simulation Models 3/24/00 EXTENSION OF EXISTING DESIGN AND SIMULATION MODELS

Ground-Coupled Heat Pump And Energy Storage

Pitfalls of Rules of Thumb in Geothermal Heat Pump Design

BETTER BUILDINGS BY DESIGN Sheraton Conference Center Burlington, Vermont. February 8, 2012

The Part-Load Efficiency Benefit of Oil-Free, High- Speed, Direct-Drive Centrifugal Compressors

Component-Based Vapor Compression Simulation Tool With Integrated Multi-Objective Optimization Routines

COMPARISONS BETWEEN TRNSYS SOFTWARE SIMULATION AND F-CHART PROGRAM ON POOL HEATING SYSTEM

A Scroll Expander with Heating Structure and Their Systems

Simulation Studies on Performance of Solar Cooling System in UAE Conditions

PRELIMINARY INTERMODEL COMPARISON OF GROUND HEAT EXCHANGER SIMULATION MODELS

GHP Data Collection and Monitoring System at the SRRL

RESIDENTIAL SWIMMING POOL HEATING WITH GEOTHERMAL HEAT PUMP SYSTEMS

An Evaluation of the Fort Polk Energy Savings Performance Contract. Patrick J. Hughes John A. Shonder Oak Ridge National Laboratory

In-Depth Exploration of Ground Source Heat Pump Technologies

Unitary Air Conditioner Field Performance

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

Fundamental Investigation Of Whole-Life Power Plant Performance For Enhanced Geothermal Systems

FIRST LARGE-SCALE SOLAR SEASONAL BOREHOLE THERMAL ENERGY STORAGE IN CANADA

Transcription:

Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2010 Research on Ground Source Heat Pump Design Amanda Jo Pertzborn University of Wisconsin Madison Gregory Nellis University of Wisconsin Madison Sanford Klein University of Wisconsin Madison Follow this and additional works at: http://docs.lib.purdue.edu/iracc Pertzborn, Amanda Jo; Nellis, Gregory; and Klein, Sanford, "Research on Ground Source Heat Pump Design" (2010). International Refrigeration and Air Conditioning Conference. Paper 1048. http://docs.lib.purdue.edu/iracc/1048 This document has been made available through Purdue e-pubs, a service of the Purdue University Libraries. Please contact epubs@purdue.edu for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html

2202, Page 1 Research on Ground Source Heat Pump Design Amanda Pertzborn 1 *, Gregory Nellis 2, Sanford Klein 3 1 University of Wisconsin - Madison, Solar Energy Laboratory, Madison, WI, USA apertzbo@uwalumni.com 2 University of Wisconsin - Madison, Solar Energy Laboratory, Madison, WI, USA gfnellis@engr.wisc.edu 3 University of Wisconsin - Madison, Solar Energy Laboratory, Madison, WI, USA gfnellis@engr.wisc.edu klein@engr.wisc.edu * Corresponding Author ABSTRACT One of world s largest uses of energy is the heating and cooling of buildings. Ground Source Heat Pumps (GSHP) provide a more energy efficient way to meet building energy needs than conventional alternatives. At a relatively shallow depth, the ground temperature is nearly constant year round providing a reliable heat source or sink for the operation of a heat pump. The design of such systems is complicated by the short and long term behavior of the ground as well as various options for system configuration and control. The stochastic nature of year-to-year weather variation also influences the design. In this paper the GSHP system is introduced and the system model developed at the UW-Madison is discussed. The impact of weather variation on the optimal design of such a system is examined. Initial validation of the key component in the model, the ground heat exchanger, against experimental data is presented. 1. INTRODUCTION Air source heat pumps use the outdoor air as a heat source or sink to supply heating and cooling to a building. In most locations, the air temperature varies significantly throughout the year leading to a reduction in system efficiency; the efficiency of a heat pump decreases as the difference between the indoor and outdoor temperatures increases. However, at a relatively shallow depth, the ground temperature essentially remains constant at a moderate temperature (e.g., 5-10 C) throughout the year. The ground, therefore, can provide consistently high system efficiency when it is used as the heat source or sink for a ground source heat pump (GSHP). There are a variety of ways to implement a GSHP, but this work is focused on the vertical heat exchanger (VHE) design. A VHE consists of a borehole (0.15 m diameter typical) that is drilled into the ground to a depth that is dependent on the local geography; depths of 45 to 90 m are common. A high density polyethylene pipe (2.5 to 5 cm typical) is placed in the hole. This pipe has a u-bend at the bottom so that the working fluid flows down one leg of the pipe and up the other leg. The number of boreholes is based on the expected load of the building (or buildings) and they are typically spaced 4.6 to 6 m apart. The entire array of boreholes is referred to hereafter as the ground heat exchanger (GHX). The boreholes are tied together in a header and that is connected to the building. The working fluid in this system is a water or water-antifreeze mixture (in cold regions; propylene glycol is most

common); the working fluid is used to transfer energy between the heat pump and the ground. This system is typically used with water-to-air or water-to-water heat pumps in the building. 2202, Page 2 Figure 1 is an illustration of this system as applied to a house (based on Kavanaugh, 2009), showing the heat flow that occurs during summer and winter. Heat is removed from the house and rejected to the ground in the summer and removed from the ground and rejected to the house in the winter. The figure also points out an advantage of the GSHP; the ground can provide long-term storage so that the heat rejected to the ground during the summer can balance the heat absorbed in the winter, thereby leaving the ground temperature relatively unchanged over time. These systems have been applied to single family homes, multi-unit buildings, office buildings and schools. In addition to the advantages of GSHPs already presented, there are some difficulties. Although GSHPs typically have lower maintenance and operating costs than conventional systems, they also often have higher first costs due to the expense of drilling the boreholes. When implemented in cooler regions, where there are high heating loads, antifreeze must be included in the working fluid to prevent freezing during operation. This system also requires a separate outdoor air system, which can be an advantage in some situations, but can also be viewed as an extra piece of equipment. One of the primary disadvantages of GSHPs that this work hopes to address is a lack of familiarity by designers, building owners, and sub-contractors with how to best implement and construct the system. The performance characteristics of a GSHP system make it an attractive option for reducing building energy use and carbon footprint as documented in a study sponsored by the US DOE EERE (Energy Efficiency and Renewable Energy) Geothermal Technologies Program (Hughes, 2008). In the United States, according to the report, buildings account for 40% of energy consumption and green house gas (GHG) emissions as well as 72% of the electricity and 55% of the natural gas consumption. GSHPs have higher efficiency than conventional air source heat pump systems, so they generally use less electricity and have lower carbon footprints than comparable conventional heating and cooling systems. A DOE funding opportunity program was partially based on the findings of this study. The topics available for request for proposals included the collection of validation data from existing systems and the development of software tools for the design of GSHP systems, which will help those unfamiliar with GSHP design. This paper will discuss three investigations involving GSHPs. The first section will review the work performed by Hackel et al. (2009) to develop a distributable design tool. The second section will discuss the influence that weather variation has on the design of a GSHP and the third section will discuss validation work in progress. Additional planned work is included in the conclusions. Heat is transferred from the building air to the fluid in the heat pump Heat is transferred from the fluid to the building air in the heat pump Heat is transferred from the fluid to the ground Heat is transferred from the ground to the fluid Cooling Heat rejected in cooling can be used for heating Heating Figure 1. Example of a VHE ground source heat pump system (based on Kavanaugh, 2009).

2202, Page 3 2. Hybrid Ground Source Heat Pumps GSHP systems offer the advantages of higher efficiency and reliability as compared to conventional systems, but they have several disadvantages, including potentially higher installation costs and a lack of familiarity for many designers. One of the primary causes of higher costs is the expense of drilling the boreholes for the GHX. The number of boreholes is often based on the requirement that the GHX meet 100% of the design load of the building. In most of the United States, the heating and cooling loads are not balanced. Therefore, the ground temperature will change over time, which will negatively impact the long term system efficiency; in order to meet the building load during the life of the system even as the efficiency decreases, a larger GHX (more boreholes) must be used in an unbalanced climate, leading to even greater installation costs. One alternative is to use a hybrid ground source (or ground coupled) heat pump (HyGCHP) system. In this situation, a conventional component such as a boiler or cooling tower is used to supplement the GSHP. The supplemental source provides some of the building load which reduces the required size of the GHX and also tends to balance the heat rejection and extraction associated with the ground so that the ground temperature can be maintained at a reasonable level. 2.1 Model Description Hackel et al. (2009) developed a distributable model of the HyGCHP system integrated with an optimization engine that could be used to determine the optimal size of the GHX and the supplemental component as well as the various control setpoints for the system. This model was developed in TRNSYS (TRaNsient SYstem Simulation), which is a flexible, powerful tool for simulating energy systems, especially as related to buildings (Klein et al., 2006). This program calculates the hourly variation in the ground temperature and the resulting change in the efficiency of the total system over the life of the system, which is usually ten to thirty years. As the ground temperature changes, the system efficiency is degraded and a larger GHX is required unless there is a supplemental source. HyGCHP sizes the GHX and supplemental component based on minimizing the life cycle cost (LCC) of the design subject to the constraint that the system be capable of meeting the peak load experienced by the building over its entire life. Because LCC is the optimization parameter, the optimal design is not necessarily one where the cooling and heating loads to the GHX are balanced (i.e., where the ground temperature remains constant), but rather one in which the temperature of the ground may increase or decrease over time in a controlled manner. In this way, the ground is used up at the end of life and, as a result, the supplemental component bears more of the load over time. Figure 2 shows a basic schematic of the cooling tower hybrid configuration modeled by the HyGCHP simulation. The program implements a control algorithm that turns the cooling tower and GHX on or off based on temperature setpoints. The simulation is allowed to run for the system's operational lifespan in order to compute a LCC. The control setpoints and size of the equipment are varied in order to minimize the LCC. Figure 2. Schematic of a cooling tower hybrid GSHP system.

2202, Page 4 2.2 Model Limitations The existing HyGCHP program has two primary limitations; it is slow and it has not been completely validated. The optimization is a slow process because the entire life of the system must be modeled for each set of potential optimization parameters. Because the system is characterized by important time scales ranging from minutes (for control decisions) to months (for seasonal variations) to years (for long term variations in the ground temperature) it is necessary to simulate several decades with sub-hourly time steps. The optimization process requires carrying out many of these simulations, which is computationally time consuming. The second limitation, validation, is being addressed as discussed later in this report. 3. Weather Variation The performance of the GSHP is dependent on how much energy is transferred between the working fluid and the ground. As energy is rejected or extracted from the ground, the ground temperature changes; this variation can occur over both a short time period and a long time period. The HyGCHP program calculates the ground temperature based on the building loads for each hour of, in this study, the 20 year simulation. In the standard methodology, the building loads are calculated using a weather file that is based on a Typical Meteorological Year (TMY) which is obtained by constructing an average year based on observations over a 30 year period (NREL, 2009a). This representation of the weather cannot incorporate the year-to-year variation in weather. The design obtained using TMY weather data will therefore be over-sized for particularly mild years and under-sized for severe weather years. Therefore, an optimal GSHP design that is based on weather data that includes year-to-year variations and therefore the impact of unusually severe weather years will be different from a design based on a TMY weather file. The evaluation of the significance of year-to-year weather variation on the optimal design is briefly presented in this section. 3.1 Description of Investigation Building loads were calculated for a 455 m 2 heating-dominated (i.e., the heating load is larger than the cooling load on an annual basis) building located in Madison, WI. Only 15 years of data were available (NREL, 2009b); therefore, five of the fifteen years were repeated in order to bring the total simulation time to 20 years. The building was modeled as a small office building. Due to its size, the building loads should reflect the variation in the weather conditions. 3.2 Results The optimal design for this building using annual weather data has been normalized by the optimal design using TMY weather data; the results are presented in Figure 3 normalized by the TMY results, with the optimal value of each of the parameters based on the TMY model shown above each bar. The key parameters are: LCC Life Cycle Cost L GHX Length of the Ground Heat Exchanger Q boiler Capacity of the boiler T g Change in ground temperature over 20 years Q rej Heat rejected to the ground over 20 years Q abs Heat removed from the ground over 20 years The optimal size of the GHX is the same for both designs, but the boiler size increases by 11% when 15 years of actual weather data are used. In this heating dominated case, the ground temperature decreases over time due to the large imbalance between the amount of energy removed from the ground during the heating season and added to the ground during the cooling season. When 15 years of actual data are used, the ground temperature still decreases over time, but the decrease is 5.6% less than when TMY data are used. This effect is not due to lower heating demand for the annual data, but rather the use of a larger boiler meeting more of the load than in the nominal case. The LCC decreases slightly when 15 years of actual data are used for design. This decrease occurs because the average peak heating load for the 15 years of actual data is less than the peak heating load for the TMY data; although the heating load is more severe in at least one year of the 15 years of actual data, overall the heating load is less severe. The consequence of using the TMY weather file for design is that the system is undersized and therefore unable to meet the heating load associated with an unusually cold year. When the optimizer is provided with actual yearly weather

2202, Page 5 data, it elects to increase the size of the supplemental heating system (the boiler) in order to accommodate severe weather years. Similar results are seen for a cooling dominated design. 4. Validation One of the limitations of the HyGCHP model is a lack of both component and system validation. Thanks to the receipt of a DOE grant, data from operational HyGCHP systems are being obtained and will be used to validate the model. The initial effort has focused on validating individual components. This section describes preliminary short time-scale validation of the ground heat exchanger model using a residential building in Madison, WI. 4.1 Description of the Investigation The DST (Duct STorage Model) is implemented in TRNSYS as Type 557 in order to model a vertical ground heat exchanger. The DST model incorporates the effects of the entire storage volume and the interaction between the vertical bores on the performance of the heat exchanger. The temperature of the working fluid entering the GHX and the estimated flow rate, based on experimental data, are inputs to the model. The primary output from Type 557 is the temperature of the working fluid exiting the GHX. This value is compared to the measured value. Figure 4 is a schematic system being modeled. The pump for the GHX is labeled G and the pumps for the building loop are labeled A and B. The inlet and outlet temperature of the GHX are labeled G in and G out. Annual Weather Data/TMY Weather Data 1.15 1.10 1.05 1.00 0.95 0.90 0.85 0.80 $134,488 LCC 675 m (2215 ft ) LGHX 116 kw (397 MBH) Qboiler -8.8 C (-15.9 F) Tg 1744 GJ (1653 MMBtu) Qrej 16475 GJ (15615 MMBtu) Qabs Figure 3. Characteristics of a boiler hybrid designed for the building in Madison using 15 years of actual annual weather data.

2202, Page 6 B G out A Boiler Ground G in Bypass = Flow measuring valve = Mixing/diverting valve Building/ Heat Pumps G = Pump Figure 4. Schematic of the GHX and building loops. 4.2 Results The top plot in Figure 5 shows the output temperature of the ground loop calculated by using the DST overlaid onto the measured outlet temperature as a function of time. The temperature output from the DST follows the measured results, but initially it is slightly higher. Over time, the magnitudes of the temperatures become nearly identical. This behavior is also displayed in the bottom plot, which shows the difference between the DST temperature results and the measurements. Initially this difference is on the order of 1 C, but over time it decreases to within 0.5 C. This comparison may be improved by adding an initial development period to establish the correct initial temperature distribution in the ground for the DST model. Figure 6 is a histogram of the difference between the model and the measurement. A difference of 0.5 C is considered to be within measurement error, so these results need to be further examined and more data need to be used for comparison before any final conclusion can be drawn. It is known that the results are highly sensitive to the ground thermal conductivity, which is difficult to know precisely, so this is a parameter that may need to be tuned. Based on this preliminary study, the DST model can be an accurate approximation to reality, but it may require some tuning.

2202, Page 7 Figure 5. Top: Temperature calculated using the DST model and measurements. Bottom: Difference between the outlet temperature from the DST model and measurements. Figure 6. Histogram of the difference between the model and the measurement. 5. CONCLUSIONS An overview of the work being conducted on GSHPs at the University of Wisconsin Madison has been presented. The work to date has found that designs based on TMY weather data may under-predict the required component sizes because the actual year-to-year weather variation is ignored. Initial validation of the component used to simulate the GHX (the DST model) has shown that the model can predict the outlet temperature of the GHX for short term simulations, but additional validation is required. Additional validation of the DST model will be performed as data is collected from the site in Madison as well as from additional sites in Las Vegas, NV. The heat pump component model will also be validated. This validation is limited to "short term" simulations because data are not available for the full life of the system (which is several decades). Once the key components have been validated, models of the existing buildings and integrated systems will be validated. These models will be used as baseline test models for evaluating the accuracy of the generic HyGCHP models.

2202, Page 8 NOMENCLATURE A pump in the building schematic B pump in the building schematic DOE Department of Energy DST duct storage model G GHX pump in the building schematic G in temperature at the GHX inlet in the building schematic [ C] G out temperature at the GHX outlet in the building schematic [ C] GHX ground heat exchanger GSHP ground source heat pump HyGCHP hybrid ground coupled heat pump LCC life cycle cost over 20 year simulation [$] L GHX ground heat exchanger length [m] NREL national renewable energy laboratory Q abs heat removed from the ground over 20 years [GJ] Q boiler boiler capacity [kw] Q rej heat rejected to the ground over 20 years [GJ] T g change in ground temperature after 20 years [ C] TMY typical meteorological year TRNSYS transient systems simulation REFERENCES Hackel, S, et al., 2008, Development of Design Guidelines for Hybrid Ground-Coupled Heat Pump Systems, ASHRAE Research Report-RP-1384. Hellström, G,1989, Ground Heat Storage Model: Manual for Computer Code, Department of Mathematical Physics University of Lund, Sweden. Hughes, P, 2008, Geothermal (Ground-Source) Heat Pumps: Market Status, Barriers to Adoption, and Actions to Overcome Barriers, ORNL/TM-2008/232. Kavanaugh, S, 2009, How Ground/Water Source Heat Pumps Work, http://www.geokiss.com/consumerinfo/howg&wsourceheatpumpswork.pdf. Klein, S.A., et al, 2006. TRNSYS, A Transient System Simulation Program, User s Manual, Version 16, Solar Energy Laboratory, University of Wisconsin-Madison NREL. 2009a,National Solar Radiation Data Base, 1961-1990: Typical Meteorological Year 2. http://rredc.nrel.gov/solar/old_data/nsrdb/tmy2/. NREL, 2009b. National Solar Radiation Data Base, 1991-2005 Update. http://rredc.nrel.gov/solar/old_data/nsrdb/1991-2005/. ACKNOWLEDGEMENT This work was performed at the University of Wisconsin - Madison Solar Energy Lab with funding provided by NIST and the DOE. The HyGCHP tool used in this program was developed by Scott Hackel of the Energy Center of Wisconsin and Jeff Thornton of TESS. We would particularly like to thank Scott Hackel for his contributions to and support of this work.