Proudly Made in the U.S.A.

Similar documents
Proudly Made in the U.S.A.

Proudly Made in the U.S.A. 5-Year Warranty. Wayfinding Products

Proudly Made in the U.S.A. 5-Year Warranty. Wayfinding Products

Proudly Made in the U.S.A. 5-Year warranty. Radius TacTile. cast-in-place Replaceable (wet-set) or surface mount.

CAST IN PLACE TACTILE / DETECTABLE WARNING SURFACE TILES

Surface Mount Tactile

HEAVY DUTY CAST IN PLACE REPLACEABLE TACTILE / DETECTABLE WARNING SURFACE TILES

HERCULITE REPLACEABLE CAST IN PLACE DETECTABLE/TACTILE WARNING SURFACE TILE

Yours truly, John Heffner Access Products Inc. National Sales Manager

1.02 DESCRIPTION A. This Section specifies furnishing and installing Surface Applied Detectable/Tactile Warning Surface Tiles where indicated.

STAGGERED DOME SURFACE APPLIED TACTILE / DETECTABLE WARNING SURFACE TILES (For Transit Use)

MODULAR PAVER DETECTABLE/TACTILE WARNING SURFACES

SECTION DETECTABLE GUIDE TACTILES

DIRECTIONAL BAR TILE / WAY-FINDING SURFACE TILES (Wet-Set and Surface Applied)

SURFACE APPLIED TACTILE / DETECTABLE WARNING SURFACE TILES (Rectangular and Radius Tiles)

1. Payment for concrete sidewalks is on square foot basis. a. Limits for measurement for trench excavation as follows:

SECTION PAVER TILE

RediMat. surface applied. Features. Physical Characteristics. Installation. Colors. Sizes. the original flexible surface applied mat

CAST IN PLACE DETECTABLE/TACTILE WARNING SURFACES SECTION DETECTABLE/TACTILE WARNING SURFACES

Section CONCRETE SIDEWALKS. 1. Payment for concrete sidewalks is on square foot basis.

SURFACE APPLIED 3" X 48" ADVANCED WARNING STRIP SECTION 09614

SECTION DETECTABLE/TACTILE WARNING SURFACES

Wears Like Iron Because it is Iron!

SUDAS Revision Submittal Form

SUDAS Revision Submittal Form

A. Prepare formwork shop drawings using qualified professional engineer. Include detail of fabrication, assembly, and support of formwork.

CONSTRUCTION SPECIFICATION FOR CONCRETE SIDEWALK

SECTION RIGID PAVEMENT

CITY OF FARGO SPECIFICATIONS CONCRETE SIDEWALKS AND DRIVEWAYS

MANUFACTURER S SPECIFICATIONS Section LIME CONCRETE. A. This section describes the requirements for floors and slabs on grade.

CELCORE CELLULAR INSULATING CONCRETE SPECIFICATION FOR RETROFIT PLACEMENT OVER EXISTING ROOF MEMBRANES

SECTION CONCRETE PAVING

DIVISION 3 - CONCRETE Section Concrete Toppings Section Concrete Resurfacing Section Concrete Rehabilitation

PRODUCT GUIDE SPECIFICATION

CONCRETE WALKS AND CURBS SECTION CONCRETE WALKS AND CURBS PART 1 - GENERAL

DIVISION 3 CONCRETE Section Concrete Rehabilitation

TILT-UP PRECAST CONCRETE SANDWICH PANELS. A. Work includes, but is not limited to, the following:

SECTION [ ] MANUFACTURED METAL BOLLARDS

SECTION SITE CONCRETE

First Class Building Products, Inc.

ThermalShell Modular Insulated Pre-Cast Panels

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

A. Section includes cast-in-place concrete, including reinforcement, concrete materials, mixture design, placement procedures, and finishes.

WEIGHT PER PIECE (LBS.)

SECTION MISCELLANEOUS CAST-IN-PLACE CONCRETE

SECTION ~ CURB AND SIDEWALK PART 1.00 ~ GENERAL

SECTION TILT-UP PRECAST CONCRETE SANDWICH PANELS. A. Work includes, but is not limited to, the following:

SECTION EMBEDDED CMU/SPLIT FACE ARCHITECTURAL PRECAST/SITECAST CONCRETE. A. Site Cast or Tilt-Up CMU/Split Face Concrete Panels.

Narrow Modular Pavers (NMP) for Sand-Set Installations

SECTION CAST IN PLACE CONCRETE FOR FLOOR SLABS ON GRADE THAT WILL RECEIVE SEMI-PERMEABLE OR IMPERMEABLE FLOOR FINISHES

Desco Quartz Cremona Specifications

Editing notes to assist users are included within bordered boxes. Delete these notes prior to final printing.

SECTION Arisfor WallGuard

SECTION BRICK FLOORING

Concrete Repair & Restoration

SECTION PORTLAND CEMENT CONCRETE

SECTION UNIT PAVERS

BIDDING & CONTRACT DOCUMENTS Document Addendum #1

Product Guide Specification

Understanding ADA Compliance and Guidelines for Detectable Warnings

RENEW ELASTOMERIC ACRYLIC COATING (PAINT GRADE) MANUFACTURERS SPECIFICATION / SECTION

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

ACO Specification Information

A. General: Refer to and comply with Division 1 Section Submittal Procedures, for procedures and other submittal criteria.

Fiber Reinforced Polymer (FRP) Panels for Rail Station Platforms

SECTION CEMENT AND CONCRETE FOR EXTERIOR IMPROVEMENTS

Concrete Field Testing Technician Study Guide

prospec.com Concrete Repair & Restoration

SECTION BRICK FACED ARCHITECTURAL PRECAST CONCRETE. A. Section Cast-In-Place Concrete: Concrete, reinforcing, anchors, etc.

CRD-C Standard Test Method for Comparing Concretes on the Basis of the Bond Developed with Reinforced Steel

CONCRETE MATERIALS PROPERTIES AND TESTING

SECTION MECHANICALLY ASSISTED MOBILE STORAGE SHELVING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

Premium Fiberglass Products. QUALITY SPEED RELIABILITY Molded - Pultruded - Treads - Structurals - Ladders - Handrails

MANUFACTURER S SPECIFICATIONS SECTION EXTERIOR-INTERIOR LIME PLASTER

Section Shotcrete

GRATING PRODUCTS. PROGrid and PROGrate

SECTION CAST-IN-PLACE CONCRETE

(Specification writer shall choose the most appropriate section that applies to a given scope of work) SECTION Painting and Coating

SECTION CAST IN PLACE CONCRETE PART 1 GENERAL 1.01 RELATED DOCUMENTS

REFLECTIVE FACE CONCRETE MASONRY UNITS

SECURE LOCK INTERLOCKING TILES Product Guide Specification

SECTION MINOR CONCRETE

SECTION CONCRETE PAVING FOR PEDESTRIAN AREAS. A. This Section includes exterior cement concrete pavement for the following:

XTREME-BOND INSTALLATION SYSTEM

Blue Sky Interlocking Playground Tile - Product Guide Specifications

RUSTIC FIRE PIT SIENNA QUARRY GRAY TAN AUTUMN BLEND.

2014 Capital Project Phase 3 Grand Island Central School District Cannon Design Project No SECTION PAVING PART 1 - GENERAL

SECTION PRECAST CONCRETE PAVERS AND PEDESTAL LOK DOWN SYSTEM

Yours truly, John Heffner Vice President Access Products Inc.

DIVISION 3 - CONCRETE Section Concrete Rehabilitation

DURALAST Detectable Warning Plates

AMENDMENTS Manual of STANDARD SPECIFICATIONS. Adopted by Standard Specifications Committee. Amendment. No. 7. Published by

1-2-3MORTAR Modified Portland cement based mortar, to be used to adhere any prefabricated construction elements

1.2 Reference Standard: NOFMA - National Oak Flooring Manufacturers Association Grading Standards.

Section Wood Veneer Ceiling Tiles Micro Perforated

SECTION CAST-IN-PLACE CONCRETE

A. This Section includes traffic coatings for the following applications:

Report Title: Testing Different Materials for Tactile Walking Surface Indicators Pilot Project Evaluation Report

SECTION CONCRETE CURBS, GUTTERS AND SIDEWALKS. A. Formwork complete with shoring, bracing and anchorage.

SPECIAL PROVISIONS - SP2014 BOOK Page 1 October 8, 2013

Transcription:

5-Year Warranty Proudly Made in the U.S.A. Cast-In-Place (wet-set)

2 Cast-In-Place (wet-set) Tactile

Proudly Made in the U.S.A. In stock colors White 37875 Brick Red 20109 Yellow 33538 Blue 15187 Safety Red 31350 Seattle Yellow 23594 Black 37038 Dark Gray 36081 Clay Red 22144 3

Installation Procedure Be sure to read and understand all of these instructions before you begin. A. B. C. D. E. F. G. H. The physical characteristics of the concrete shall be as specified in the contract documents while maintaining a slump range of 4-7 to permit the solid placement of the Tactile Unit in the wet cement. The concrete shall be poured and finished level, true and smooth to the required dimensions prior to the placement of the Tactile Unit. Place the Tactile Unit 6-8 inches from the curb line. Working in a grid pattern, tamp the Tactile Unit into the wet concrete using a rubber mallet and a piece of wood. Continue this process until all of the air has been released, and the Tactile Unit surface is flush with the surrounding area. IMPORTANT: Avoid striking the surface of the Tactile Unit directly. Following the placement, the Tactile Unit elevation should be checked to the adjacent surface with a straight edge. The Tactile Unit elevation should be consistent with the contract drawings and specifications. Any required adjustments must be made prior to the time when the concrete begins to set. IMPORTANT NOTICE TO INSTALLER: To allow for expansion and contraction, after tile is installed, use a 1/4 finish edge trowel around entire perimeter. On a continous run, be sure to space each unit 1/8 apart. When you are confident that the Tactile Unit is in place, and no further adjustments are needed, place a cinder block on both ends to hold the Tactile Unit in place while the concrete sets. During and after the Tactile Unit installation, as well as the concrete curing stage, no walking or external forces can be placed on the Tactile Unit. The area must be protected from pedestrian traffic until concrete is cured. The Tactile Warning Surface will be ready for pedestrian traffic within 2-4 hours. Be sure to remove plastic protective covering from the face of the Tactile Unit once the concrete is cured. View additional photos, drawings and specifications on our website:. Call (800) 372-0519 with any questions. PRODUCT SIZES 2 x3 2 x4 2 x5 3 x4 3 x5 APPLICATION Fresh Pour Concrete Ramps 4

DOME GEOMETRY In accordance with ADA Regulations for Detectable Warning on Curb Ramps: Raised truncated domes with a diameter of nominal 0.9, a height of nominal 0.2, and a center-to-center spacing of 1.67 minimum, and 2.35 maximum. PANEL DIMENSIONS Tactile Units are available in 2 x3, 2 x4, 2 x5, 3 x4 and 3 x5 sizes. Tactile Units may also be custom configured to accommodate specific project requirements. Tactile Units measure 0.25 nominal thickness and feature embedment ribs at 3 on center. MATERIAL A durable exterior grade homogenous glass, carbon, and fiberglass reinforced composite material which is colorfast and UV stable. The color of the Tactile Unit is uniform throughout and does not rely on any type of paint coating to achieve color stability. Standard colors include: Federal Yellow, Seattle Yellow, White, Brick Red, Clay Red, Safety Red, Blue, Dark Gray and Black. For superior wheelchair, walker and shopping cart mobility, truncated domes have a center-to-center (horizontally and vertically) spacing of 2.35 inches. INSTALLATION Tactile Units are to be used on new curb ramp locations. The Tactile Units can be pre-filled with concrete and set in place or pressed into place in the freshly poured concrete. Cast-In-Place Tactile Inline Dome Pattern PHYSICAL CHARACTERISTICS Compressive Strength 28,900 psi ASTM D 695 Flexural Strength 29,300 psi ASTM D 790 Water Absorption.07% ASTM D 570 Slip Resistance 1.18 Dry, 1.05 Wet ASTM C 1028 Flame Spread Index 20 ASTM E 84 Salt Spray No Change (200 hours) ASTM B 117 Chemical Stain Testing No Deterioration ASTM 1308 Abrasion Resistance 549 ASTM C 501 Accelerated Weathering Delta E<5.0 (2,000 hours) ASTM G 155 Tensile Strength 11,600 psi ASTM D 638 Load Bearing at 16,000 lbs. No Damage AASHTO-H20 Freeze/Thaw/Heat No Disintegration ASTM C 1026 Color Throughout 5-Year Warranty 5

24 x36 (610 x 914mm) Tile 1.67 (42.4 mm) Dome Spacing 6

24 x36 (610 x 914mm) Tile 2.35 (59.7 mm) Dome Spacing 7

24 x48 (610 x 1219mm) Tile 1.67 (42.4 mm) Dome Spacing 8

24 x48 (610 x 1219mm) Tile 2.35 (59.7 mm) Dome Spacing 9

24 x60 (610 x 1524mm) Tile 1.67 (42.4 mm) Dome Spacing 10

24 x60 (610 x 1524mm) Tile 2.35 (59.7 mm) Dome Spacing 11

36 x48 (914 x 1219mm) Tile 1.67 (42.4 mm) Dome Spacing 12

36 x48 (914 x 1219mm) Tile 2.35 (59.7 mm) Dome Spacing 13

36 x60 (914 x 1524mm) Tile 1.67 (42.4 mm) Dome Spacing 14

36 x60 (914 x 1524mm) Tile 2.35 (59.7 mm) Dome Spacing 15

PRODUCT INFORMATION / SUBMITTAL 8/13