AUSTRALIAN MEDICAL DEVICES GUIDANCE DOCUMENT NUMBER 5. The Declaration of Conformity

Similar documents
Therapeutic Goods (Medical Devices) Regulations 2002

Product quality review for listed Complementary Medicines

BSI Audits for MDR Certification

GUIDANCE NOTE FOR MANUFACTURERS OF CUSTOM-MADE MEDICAL DEVICES

Medical Device Regulatory Framework 9 SEPTEMBER 2015 FUNDISA CONFERENCE JANE ROGERS

QMS Aspects of the MDR (& IVDR)

Changes to the Medical Devices Directive and affect on Manufacturers

Essential Requirements Straumann Custom-made Dental Restorative Devices According to 93/42/EEC annex I as amended by 2007/47/EC

HOW TO APPLY FOR MEDICAL DEVICE REGISTRATION UNDER MEDICAL DEVICE ACT 2012 (ACT 737)

Due diligence in the European medical devices industry

Med-Info. Directive 98/79/EC on in-vitro diagnostic medical devices. TÜV SÜD Product Service GmbH

Guidance Document. Guidance for Risk Management Programme (RMP) Template for Dairy Processors. Liquid Milk, Domestic Supply.

Guide to the in-vitro diagnostic medical devices legislation

Regulatory Framework for Medical Device

COMMISSION RECOMMENDATION. of XXX. on the audits and assessments performed by notified bodies in the field of medical devices

Guidance Document. Guidance for Risk Management Programme (RMP) Template for Dairy Processors - Yoghurt Domestic Supply

The New EU Medical Device Regulation (MDR) An Active Device Lifecycle Approach Implementation and Remediation Activities

Specific Accreditation Criteria Infrastructure and Asset Integrity ISO/IEC and ISO/IEC Annex. Lifting equipment assessment

MEDICINES CONTROL COUNCIL

MEDICINES CONTROL COUNCIL

Guidance Document. Guidance for Risk Management Programme (RMP) Template for Dairy Processors - Cheese Domestic Supply

CRT 2 NEWS. Interpretative Documents from the Commission

Medical Devices. LATVIA LAWIN Klavins & Slaidins

Guide for Class I Manufacturers on Compliance with European Communities (Medical Devices) Regulations, 1994

PROPOSED REVISED DOCUMENT

GS1 Ireland Healthcare User Group (HUG) Information Day

Update to the Manufacturing Principles for Medicinal Products

Medical Device Regulatory Framework

Medical Device Regulatory Roadmap SAMED Conference 2-3 December 2015

Manufacturers. Factsheet for. of Medical Devices. Medical Devices Regulation (MDR) background. Act now to be ready on time!

CABINET OF MINISTERS OF UKRAINE

GUIDANCE ON THE GMP CLEARANCE OF OVERSEAS MEDICINE MANUFACTURERS

DRUG DRAFT GUIDELINE FOR REGISTRATION OF MEDICAL DEVICES FOR HUMAN USE IN UGANDA, SEPTEMBER 2009

Manufacturers. Factsheet for. of Medical Devices. Medical Devices Regulation (MDR) background. Act now to be ready on time!

GENERAL AND ORGANISATIONAL REQUIREMENTS

POSITION PAPER Moving from the MDD to the MDR

Update on the IVDR. Sue Spencer

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

ANMAT Order No 5260/2008

An introductory guide to the medical device regulation (MDR) and the in vitro diagnostic medical device regulation (IVDR)

The challenges of software medical device regulation.

Medical Device Directive

White Paper: Improvements to the Australian Regulatory System for Medical Devices. 23 May 2014

GUIDANCE NOTES FOR MANUFACTURERS OF CLASS I MEDICAL DEVICES

Bariatric Solutions Australia Quality Manual. for ISO 9001:2015 Quality Management System

Medicines (Database of Medical Devices) Regulations 2003

Guidance on the Information Required for Notified Body Medical Device Personnel Involved in Conformity Assessment

Medical Devices Regulation (MDR) Readiness Review

Inspection of the conduct of clinical evaluations on medical devices in the premises of healthcare providers

VIGILANZA E SORVEGLIANZA POST- COMMERCIALIZZAZIONE

Guide to field safety corrective actions for medical devices and in-vitro diagnostic medical devices

PART 1 DEVICE MASTER FILE

MEDICAL DEVICE GUIDANCE

Changes to the Regulation of IVDs in Europe. Copyright 2012 BSI. All rights reserved.

White paper: Code of GMP Chapter 4 Documentation - PIC/S versus EU

IVDR Breakout. Copyright 2017 BSI. All rights reserved.

ASEAN AGREEMENT ON MEDICAL DEVICE DIRECTIVE

Medical Device Regulatory Roadmap SAMED Conference 2-3 December 2015

Internationally harmonised requirements for batch certification

Medical Devices Directive Compliance Essential Requirements Checklist

Conformity Assessment of Medical Devices Under The New MDR

HANDLING AND SHIPPING OF INFECTIOUS SUBSTANCES FOR CLINICAL TRIALS

FINAL DOCUMENT. International Medical Device Regulators Forum. Medical Device Regulatory Audit Reports

EUROPEAN COMMISSION HEALTH AND CONSUMERS DIRECTORATE-GENERAL. EudraLex. The Rules Governing Medicinal Products in the European Union

Course Title ID Duration Basic Premium. Biological Evaluation of Medical Devices: A Risk-Based Approach N mins

Specific Accreditation Criteria

ASEAN Consultative Committee for Standards & Quality. Medical Device Product Working Group. Common Submission Dossier Template

MINISTRY OF HEALTH OF THE RUSSIAN FEDERATION (Minzdrav of Russia) Moscow

General Safety and Performance Requirements Regulation (EU) 2017/ 745 on medical devices (MDR) - Annex I I. GENERAL REQUIREMENTS

Ready or Not: The New Medical Device Regulations Are Here!

Purchase Order Quality Clause SCC20 Revision E, Effective 1/20/2015

Quality System Requirements for Medical Devices Reference Guide for Manufacturers Selling Medical Devices in Europe, Canada and the United States

Integrated Research Application System (IRAS)

Regulated Control Scheme for Deer Velvet Harvest 4 August 2017

Checklist for the assessment based on the standards

Handling and Shipping of Infectious Substances for Research/Clinical Trials

NZQA unit standard version 3 Page 1 of 5. Inspect export forest products for phytosanitary contamination as a site inspector

Medical Devices. The technical requirements also apply when the submitter is not the legal manufacturer 1 (i.e: a distribution company).

EUROPEAN INDUSTRIAL PHARMACISTS GROUP. Guidance on CPD for QUALIFIED PERSONS

Guide for Manufacturers and Sponsors on Clinical Investigations Carried Out in Ireland

QUESTIONNAIRE FOR COMPETENT AUTHORITIES TO BE USED FOR ASSESSMENT, REASSESSMENT AND SELF- EVALUATION

ANNEX I Annex III to Regulation (EC) No 1235/2008 is amended as follows: (1) After the heading "LIST OF THIRD COUNTRIES AND RELEVANT SPECIFICATIONS

NABH-PA (BB) PRE-ASSESSMENT GUIDELINES AND FORMS FOR BLOOD BANKS/ BLOOD CENTRES. Issue No. 1 Issue Date: 04/ 08 Page 1 of 10

Overview of Regulatory Framework for Medical Devices & IVDs and likely Implementation Roadmap. Jane Rogers SAAPI Conference 13 April 2016

ASEAN GOOD REGULATORY PRACTICE (GRP) GUIDE

Experience with Directive 93/42/EEC (MDD)

Implications of the new MDR from a Product Testing and Certification Perspective

Import Health Standard

MEDICAL DEVICE. Technical file.

Companion diagnostics and the IVD Directive 98/79/EC + revision

EudraLex. Part I1 Chapter 6: Quality Control

TUV SUD BABT PRODUCTION QUALITY CERTIFICATION SCHEME

EUROPEAN COMMISSION DIRECTORATE-GENERAL FOR HEALTH AND FOOD SAFETY. EudraLex. Volume 4

Good manufacturing practices

The 2018 Therapeutic Goods Advertising Code & associated guidance

Work plan for the GMP/GDP Inspectors Working Group for 2018

Author Signature: Date: 11 October 2017 The author is signing to confirm the technical content of this document

The Gap Analysis Checklist

AND GENERAL REQUIREMENTS

Medical Device Regulation Overview

Transcription:

AUSTRALIAN MEDICAL DEVICES GUIDANCE DOCUMENT NUMBER 5 The Declaration of Conformity 30 October 2003

DISCLAIMER This document is provided for guidance only. It should not be relied upon to address every aspect of relevant legislation. Please refer to the Therapeutic Goods Act, 1989 and the Therapeutic Goods (Medical Devices) Regulations, 2002 for legislative requirements. FURTHER INFORMATION The Medical Devices Information Unit of the Office of Devices, Blood and Tissues of the Therapeutic Goods Administration (TGA) can be contacted by: Telephone: 1800 141 144 Facsimile: (02) 6232 8299 Email: cab.medical.device.information@health.gov.au Website: www.tga.gov.au/devices/devices.htm Mail: PO Box 100 Woden ACT 2606 Commonwealth of Australia 2003 Page 2 of 16

Version Number Date of Amendment AMENDMENT SCHEDULE Summary of Amendments 1.6 30 October 2003 Cover page modified watermarks removed from the Attachment 1. Page 3 of 16

CONTENTS Disclaimer...2 Further information...2 Amendment schedule...3 Introduction...5 What is a declaration of conformity?...5 Who is responsible for the conformity assessment of a medical device and the declaration of conformity?...6 Choice of conformity assessment procedure and relevant declaration of conformity...7 Attachment 1...9 Page 4 of 16

INTRODUCTION This guidance document is one of a series that has been produced to help explain the new regulatory system for medical devices in Australia that commenced on 4 October 2002. The new system has been established by the Therapeutic Goods Act, 1989 as amended by the Therapeutic Goods Amendment (Medical Devices) Bill, 2002 and the Therapeutic Goods (Medical Devices) Regulations, 2002. Many other guidance documents are available in this series. The series was developed to assist a wide-ranging audience and additional documents can be included if there is enough demand. A separate guidance document is available describing the series. Although each guidance document has been developed to provide information about particular aspects of the new medical devices regulatory system in Australia, it is expected that a certain amount of cross-referencing to other documents in the series will be inevitable. WHAT IS A DECLARATION OF CONFORMITY? As part of the conformity assessment procedures, the manufacturer of a medical device will be required to make a declaration of conformity which, in most cases, declares that the medical device complies with: the applicable provisions of the essential principles; the classification rules; and the conformity assessment procedures; before being supplied in Australia. The declaration also requires the manufacturer to provide: their name and address; details of the: scope of the declaration (including product identification information); certification; classification; nomenclature code; conformity assessment standards (quality management standards); and medical device standards (product standards); relevant to the conformity assessment procedure and the manufacture of the medical device covered by the declaration. The essential principles of safety and performance, which apply to all medical devices, are detailed in Schedule 1 of the Therapeutic Goods (Medical Devices) Regulations 2002. There are two main categories. The general principles apply to all devices. The applicability of the principles dealing with design and construction will depend on the intended purpose and properties of the medical device. The essential principles include: Page 5 of 16

General Principles the use of a medical device must not compromise health and safety the design and construction of a medical device has to conform with safety principles medical devices are to be suitable for the intended purpose long term safety medical devices are not adversely affected by transport or storage the benefits of medical devices are to outweigh any side effects Principles about Design and Construction chemical, physical and biological properties infection and microbial contamination construction and environmental properties medical devices with a measuring function protection against radiation medical devices connected to or equipped with an energy source information to be provided with medical devices clinical evidence WHO IS RESPONSIBLE FOR THE CONFORMITY ASSESSMENT OF A MEDICAL DEVICE AND THE DECLARATION OF CONFORMITY? The responsibility for the classification and the conformity assessment of a medical device rests with the manufacturer of the medical device. The choice of an appropriate conformity assessment procedure, which will be governed by the class of the medical device, is left to the manufacturer. The role of the TGA, or an overseas conformity assessment body, is to issue certification after it has been confirmed that the conformity assessment procedures are appropriate and have been applied. This assessment will vary according to the class of the device. More information about these requirements can be found in the guidance document titled Conformity Assessment Procedures. Assessment by the TGA is also required for Australian manufacturers of medical devices intended for supply in Australia. In addition, the TGA will undertake assessments of overseas manufacturers when requested by sponsors of imported devices. The wording of the declaration of conformity will depend on the conformity assessment procedure chosen by the manufacturer. Templates for each of the six possible types of declarations of conformity have been included as attachments to this guidance document. The italicised comments in the templates enclosed in the brackets < > are not template fields but rather provide some indication of the possible options that should appear in the corresponding part of the declaration form. The manufacturer of the medical device can sign the declaration of conformity or a person authorised by the manufacturer. Evidence of the authorisation may be required for the declaration to be valid. Page 6 of 16

CHOICE OF CONFORMITY ASSESSMENT PROCEDURE AND RELEVANT DECLARATION OF CONFORMITY The table below summarises the options available to manufacturers when deciding which conformity assessment procedure and which declaration of conformity is appropriate for each class of medical device. The conformity assessment procedures and declarations of conformity are detailed in the parts and clauses of Schedule 3 of the Therapeutic Goods (Medical Devices) Regulations 2002. Comparisons of Alternatives for Conformity Assessment Procedures and the Required Declarations of Conformity under Schedule 3 of the Therapeutic Goods (medical Devices) Regulations 2002, for each Class of Medical Device Class or Category of Medical Device Minimum Conformity Assessment Procedures Alternatives Declaration of Conformity Required under Schedule 3 of Therapeutic Goods (Medical Devices) Regulations 2002 Class AIMD Part 1 (Full Quality Assurance Procedures) Clause 1.8 Part 2 (Type Examination Procedures) + Part 3 (Verification Clause 3.5 Procedures) Part 2 (Type Examination Procedures)+ Part 4 (Production Clause 4.7 Quality Assurance Procedures) Class III Part 1 (Full Quality Assurance Procedures) Clause 1.8 Part 2 (Type Examination Procedures) + Part 3 (Verification Clause 3.5 6Procedures) Part 2 (Type Examination Procedures) + Part 4 (Production Clause 4.7 Quality Assurance Procedures) Class IIb Part 1 excluding Clause 1.6 (Full Quality Assurance Clause 1.8 Procedures) Part 2 (Type Examination Procedures)+ Part 3 (Verification Clause 3.5 Procedures) Part 2 (Type Examination Procedures) + Part 4 (Production Clause 4.7 Quality Assurance Procedures) Part 2 (Type Examination Procedures) + Part 5 (Product Quality Clause 5.7 Assurance Procedures) Class IIb Part 1 excluding Clause 1.6 (Full Quality Assurance Clause 1.8 (sterile) Procedures) Part 2 (Type Examination Procedures) + Part 4 (Production Quality Assurance Procedures) Clause 4.7 Page 7 of 16

Comparisons of Alternatives for Conformity Assessment Procedures and the Required Declarations of Conformity under Schedule 3 of the Therapeutic Goods (medical Devices) Regulations 2002, for each Class of Medical Device (continued) Class or Category of Medical Device Class IIa Class IIa (sterile) Class I Class I (measuring) Class I (sterile) System or Procedure Packs Minimum Conformity Assessment Procedures Alternatives Part 1 excluding Clause 1.6 (Full Quality Assurance Procedures) Assessment by the Secretary) + Part 3 (Verification Procedures) Assessment by the Secretary) + Part 4 (Production Quality Assurance Procedures) Assessment by the Secretary) + Part 5 (Product Quality Assurance Procedures) Part 1 excluding Clause 1.6 (Full Quality Assurance Procedures) Assessment by the Secretary) + Part 4 (Production Quality Assurance Procedures) Assessment by the Secretary) Assessment by the Secretary) + Part 3 (Verification Procedures) Assessment by the Secretary) + Part 4 (Production Quality Assurance Procedures) Assessment by the Secretary) + Part 5 (Product Quality Assurance Procedures) Assessment by the Secretary) + Part 4 (Production Quality Assurance Procedures) Part 7 (Procedures for Medical Devices Used for a Special Purpose) Declaration of Conformity Required under Schedule 3 of Therapeutic Goods (Medical Devices) Regulations 2002 Clause 1.8 Clause 1.8 Clause 7.5 Page 8 of 16

ATTACHMENT 1 Templates for Declarations of Conformity under Schedule 3 of the Therapeutic Goods (Medical Devices) Regulations 2002 for: Clause 1.8 Clause 3.5 Clause 4.7 Clause 5.7 Clause 7.5 Page 9 of 16

MANUFACTURER S DECLARATION OF CONFORMITY AUSTRALIAN THERAPEUTIC GOODS (MEDICAL DEVICES) REGULATIONS 2002 FULL QUALITY ASSURANCE PROCEDURE This is a declaration made in accordance with the requirements of Clause 1.8 of Schedule 3 of the Australian Therapeutic Goods (Medical Devices) Regulations 2002 relating to the stated devices <or the devices stated in the attached Schedule> Reference: Manufacturer's Name: < If a schedule is attached, a reference to this declaration must be included in the Schedule> < Person responsible for design production packaging and labelling> Business Address: Medical Device(s): < Unique Product Identifier (eg product name or model number)> < OR See Attached Schedule for multiple products > Classification: < Class of Device covered by this Declaration (AIMD, III, IIb, IIa) > < OR See Attached Schedule for the class of multiple products > GMDN Code and Term: < Code and Preferred Term > < OR See Attached Schedule for the GMDN code and term of multiple products > Scope of Application: < All OR specific or ranges of batches, lots or serial numbers, OR times of manufacture OR See Attached Schedule for multiple batches, lots or serial numbers to which the approved Full Quality Assurance Procedures have been applied> Each kind of medical device to which the Full Quality Assurance Procedures have been applied complies with the applicable provisions of the essential principles, the classification rules, at each stage, from the design of the device until its final inspection before being supplied. Full Quality Management System Certificate: < Assessment Body and Certificate Number: Conformity Assessment Certificate(s) - Full Quality Management System; OR European Medical Devices Directive Annex II without Clause 4 Certificate(s); OR European Active Implantable Medical Devices Directive Annex II Certificate(s); OR Design Examination Certificate: Standards Applied: < Assessment Body and Certificate Number: Conformity Assessment Certificate(s) - Design Examination; OR European Medical Devices Directive Annex II Clause 4 Certificate(s); OR < A standard referenced in a Medical Device Standard Order or a Conformity Assessment Standard Order; OR European Harmonised Standard; OR See Attached Schedule for multiple standards > Authorised Signatory: Name, Position Date Page 10 of 16

MANUFACTURER S DECLARATION OF CONFORMITY AUSTRALIAN THERAPEUTIC GOODS (MEDICAL DEVICES) REGULATIONS 2002 VERIFICATION This is a declaration made in accordance with the requirements of Clause 3.5 of Schedule 3 of the Australian Therapeutic Goods (Medical Devices) Regulations 2002 relating to the stated devices <or the devices stated in the attached Schedule> Reference: Manufacturer's Name: < If a schedule is attached, a reference to this declaration must be included in the Schedule> < Person responsible for design production packaging and labelling> Business Address: Medical Device(s): < Unique Product Identifier > < OR See Attached Schedule for multiple products > Classification: < Class of Device covered by this Declaration (AIMD, III, IIb) > < OR See Attached Schedule for the class of multiple products> GMDN Code and Term: < Code and Preferred Term; OR > < See Attached Schedule for the GMDN Codes and Terms for multiple products > Scope of Application: < All OR specific or ranges of batches, lots or serial numbers, OR times of manufacture OR See Attached Schedule for multiple batches, lots or serial numbers to which the verification procedures have been applied> Each kind of medical device <or batch of devices> to which the Verification Procedures have been applied conforms to an approved Type and complies with the applicable provisions of the essential principles and the classification rules before being supplied. This declaration is being made on the basis of the following certificates: Type Examination Certificate: Verification Certificate: Standards Applied: <Assessment Body and Certificate Number: Conformity Assessment Certificate(s) - Type Examination; OR European Medical Devices Directive Annex III Certificate(s); OR European Active Implantable Medical Devices Directive Annex III Certificate(s); OR < Assessment Body and Certificate Number: Conformity Assessment Certificate(s) - Verification; OR European Medical Devices Directive Annex IV Certificate(s); OR < A standard referenced in a Medical Device Standard Order or a Conformity Assessment Standard Order; OR European Harmonised Standard; OR See Attached Schedule for multiple standards > Authorised Signatory: Name, Position Date Page 11 of 16

MANUFACTURER S DECLARATION OF CONFORMITY AUSTRALIAN THERAPEUTIC GOODS (MEDICAL DEVICES) REGULATIONS 2002 PRODUCTION QUALITY MANAGEMENT SYSTEM This is a declaration made in accordance with the requirements of Clause 4.7 of Schedule 3 of the Australian Therapeutic Goods (Medical Devices) Regulations 2002 relating to the stated devices <or the devices stated in the attached Schedule> Reference: Manufacturer's Name: < If a schedule is attached, a reference to this declaration must be included in the Schedule> < Person responsible for design production packaging and labelling> Business Address: Classification: < Class of Device covered by this Declaration (AIMD, III, IIb) > < OR See Attached Schedule for the class if multiple classes> GMDN Code and Term: < Code and Preferred Term > < OR See Attached Schedule for the GMDN Codes and Terms if multiple classes > Scope of Application: < All OR specific or ranges of batches, lots or serial numbers, OR kinds of medical devices OR times of manufacture OR See Attached Schedule for multiple batches, lots or serial no.s for which the production quality assurance procedures have been applied> For each kind of medical device to which the Production Quality Assurance procedures have been applied the Type Examination procedures have also been applied. The kind of device has been shown to conform to an approved Type and to the applicable provisions of the essential principles and the classification rules before being supplied. This declaration is being made on the basis of the following certificates: Type Examination Certificate: <Assessment Body and Certificate Number: Conformity Assessment Certificate(s) - Type Examination; OR European Medical Devices Directive Annex III Certificate(s); OR European Active Implantable Medical Devices Directive Annex III Certificate(s); OR Production Quality Management System Certificate: < Assessment Body and Certificate Number: Conformity Assessment Certificate(s) - Production Quality Management System; OR European Medical Devices Directive Annex V Certificate(s); OR Conformity Assessment Standards Applied: < A standard referenced in a Conformity Assessment Standard Order; OR European Harmonised Standard; OR Other Quality Management System or process Standard; OR See Attached Schedule if multiple standards have been applied > Authorised Signatory: Name, Position Date Page 12 of 16

MANUFACTURER S DECLARATION OF CONFORMITY AUSTRALIAN THERAPEUTIC GOODS (MEDICAL DEVICES) REGULATIONS 2002 PRODUCT QUALITY MANAGEMENT SYSTEM This is a declaration made in accordance with the requirements of Clause 5.7 of Schedule 3 of the Australian Therapeutic Goods (Medical Devices) Regulations 2002 relating to the stated devices <or the devices stated in the attached Schedule> Reference: Manufacturer's Name: < If a schedule is attached, a reference to this declaration must be included in the Schedule> < Person responsible for design production packaging and labelling> Business Address: Medical Device(s): < Unique Product Identifier > < OR See Attached Schedule for multiple products > Classification: Class IIb GMDN Code and Term: < Preferred Term and Code > < OR See Attached Schedule for the GMDN Codes and Terms for multiple products > Scope of Application: < All OR specific or ranges of batches, lots or serial numbers, OR times of manufacture OR See Attached Schedule for multiple batches, lots or serial numbers to which the product quality assurance procedures have been applied> For each kind of medical device to which the Product Quality Assurance Procedures has been applied the Type Examination Procedures have also been applied. The kind of device has been shown to conform to an approved Type, and to the applicable provisions of the essential principles and the classification rules before being supplied. This declaration is being made on the basis of the following certificates. Type Examination Certificate: <Assessment Body and Certificate Number: Conformity Assessment Certificate(s) - Type Examination; OR European Medical Devices Directive Annex III Certificate(s); OR European Active Implantable Medical Devices Directive Annex III Certificate(s); OR Product Quality Management System Certificate: < Assessment Body and Certificate Number: Conformity Assessment Certificate(s) - Product Quality Management System; OR European Medical Devices Directive Annex VI Certificate(s); OR Conformity Assessment Standards Applied: < A standard referenced in a Conformity Assessment Standard Order; OR European Harmonised Standard; OR Other Quality Management System or process Standard > See Attached Schedule if multiple standards have been applied > Authorised Signatory: Name, Position Date Page 13 of 16

MANUFACTURER S DECLARATION OF CONFORMITY AUSTRALIAN THERAPEUTIC GOODS (MEDICAL DEVICES) REGULATIONS 2002 This is a declaration made in accordance with the requirements of of Schedule 3 of the Australian Therapeutic Goods (Medical Devices) Regulations 2002 relating to the stated devices <or the devices stated in the attached Schedule> Reference: Manufacturer's Name: < If a schedule is attached, a reference to this declaration must be included in the Schedule> < Person responsible for design production packaging and labelling> Business Address: Medical Device(s): < Unique Product Identifier > < OR See Attached Schedule for multiple products > Classification: < Class I OR Class I supplied sterile OR Class I with a measuring function OR Class IIa > < OR See Attached Schedule for the class if multiple products > GMDN Code and Term: < Code and Template Term for Class I, where available > < Code and Preferred Term for Class IIa or where a template term is not available for a Class I product > < OR See Attached Schedule for the GMDN code and term if multiple products > Scope of Application: < All OR specific or ranges of batches, lots or serial numbers, OR times of manufacture OR See Attached Schedule for multiple batches, lots or serial numbers to which the Declaration of Conformity (not requiring assessment by the Secretary) Procedure has been applied> <For Class IIa sterile or Class I sterile:> For each kind of medical device that is supplied sterile and to which the Conformity Assessment Procedures (not requiring assessment by Secretary) have been applied the Production Quality Assurance Procedures have also been applied. Each kind of medical device complies with the applicable provisions of the essential principles and the classification rules before being supplied. <For Class IIa non-sterile or Class I non-sterile with a measuring function:> For each kind of medical device to which the Declaration of Conformity (not requiring assessment by Secretary) procedures have been applied the <select one: the verification procedures, the production quality assurance procedures; the product quality assurance procedures> have also been applied. Each kind of medical device complies with the applicable provisions of the essential principles, the classification rules before being supplied. <For Class IIa sterile or Class I sterile or Class I with a measuring function:> < Verification Certificate OR Production / Product Quality Management System Certificate:> < Assessment Body and Certificate Number: eg TGA issued Conformity Assessment Certificate(s) Verification Production Quality Management System; OR Product Quality Management System European Medical Devices Directive Annex IV Certificate(s); OR European Medical Devices Directive Annex V Certificate(s); OR European Medical Devices Directive Annex VI Certificate(s); OR Standards Applied: < A standard referenced in a Medical Device Standard Order or a Conformity Assessment Standard Order; OR European Harmonised Standard; OR See Attached Schedule for multiple standards > Authorised Signatory: Name, Position Date Page 14 of 16

MANUFACTURER S DECLARATION OF CONFORMITY AUSTRALIAN THERAPEUTIC GOODS (MEDICAL DEVICES) REGULATIONS 2002 <SYSTEM OR PROCEDURE PACK> This is a declaration made in accordance with the requirements of Clause 7.5 of Schedule 3 of the Australian Therapeutic Goods (Medical Devices) Regulations 2002 relating to the stated <system or procedure pack or the systems or procedure packs stated in the attached Schedule> Reference: Manufacturer's Name: < If a schedule is attached, a reference to this declaration must be included in the Schedule> < Person responsible for packaging and labelling> Business Address: <System or Procedure Pack>: <Name of System or Name of Procedure Pack Identification and Contents / Components of each system or procedure pack and each item in the system or procedure pack > < OR See Attached Schedule > Classification: < Class of System(s) or Class of Procedure Pack(s) covered by this Declaration > < OR See Attached Schedule > GMDNS Code and Term: < Template Term and Code for Class I, where available > < Preferred Term and Code in all other case > < OR See Attached Schedule for the code and term if multiple products > Scope of Application: < All OR specific or ranges of batches, lots or serial numbers, OR kinds of medical devices OR times of manufacture OR See Attached Schedule > Medicine Registration or Listing: < AUSTR or AUSTL numbers for each medicine included in the system or procedure pack > Other Registration of Listing: < AUSTR or AUSTL numbers for any other therapeutic good included in the system or procedure pack > Each kind of medical device included the above <system(s) OR procedure pack(s)> have been subject to the relevant conformity assessment procedures by the manufacturer of the medical device and each medical device included in the <system(s) OR procedure pack(s)> has been shown by its manufacturer to comply with the applicable provisions of the essential principles. Each medical device in the <system(s) OR procedure pack(s)> is intended to be used for its original intended purpose and each medicine or other therapeutic good in the package is intended to be used within the approved indications for use specified by the manufacturer of those items. The mutual compatibility of each medical device, medicine or other therapeutic goods, and any other goods, in the package has been verified in accordance with any instructions for use provided by the manufacturer of each item or the approved indications for use of each item. Where applicable, the system or procedure pack has been manufactured in accordance with the original manufacturer s instructions (if any) or indications. The information supplied with the system or procedure pack for the use of the system or procedure pack includes instructions for use provided by the manufacturer of each item in the package. The process of manufacturing the system or procedure pack, and the verification and packaging of the system or procedure pack, has been subjected to a documented method of internal control and inspection that ensures the safety, quality, performance and effectiveness of each item in the package. <For a system(s) or a procedure pack(s) that contains items that are sterilised by the manufacturer of the system or procedure pack> For each kind of medical device that is sterilised by the manufacturer of the system or procedure pack the production quality assurance procedures (other than Schedule 3 Clause 4.7) have been applied to the system or procedure pack in accordance with the manufacturer s instructions for use, or the approved indications for use, of each item in the package. Page 15 of 16

Production Quality Management System Certificate: < Assessment Body and Certificate Number: Conformity Assessment Certificate(s) - Production Quality Management System; OR European Medical Devices Directive Annex V Certificate(s); OR Conformity Assessment Standards Applied: < A standard referenced in a Conformity Assessment Standard Order; OR European Harmonised Standard; OR Other Quality Management System or process Standard > See Attached Schedule if multiple standards have been applied > Authorised Signatory: Name, Position Date Page 16 of 16