INVESTIGATIONS ON THE DYNAMIC FRACTURE TOUGHNESS OF HEAVY-SECTION DUCTILE CAST IRON FOR TRANSPORT AND STORAGE CASKS

Similar documents
DYNAMIC FRACTURE TOUGHNESS BEHAVIOUR OF DUCTILE CAST IRON WITH RESPECT TO STRUCTURAL INTEGRITY ASSESSMENT

OPTIMIZATION OF WASTE CONTAINERS MADE OF DUCTILE CAST IRON BY USING RECYCLED SCRAP FROM THE NUCLEAR INDUSTRY

Fracture Properties of Ductile Cast Iron used for Thick-Walled Components

Effect of the pearlite content of ferritic cast iron material on the crack resistance behaviour under dynamic load

Meghan Oaks, Applied Process

Draft Fracture Mechanics Code Case for American Society of Mechanical Engineers NUPACK Rules

ELASTIC-PLASTIC BEHAVIOUR OF ADVANCED ADI STUDIED BY IN-SITU SEM TENSILE TEST

Edward W. Russell and Brian L. Anderson Lawrence Livermore National Laboratory Prepared by LLNL under Contract DE-AC52-07NA27344

Some Peculiarities in Deformation and Fracture Behaviour of Austempered Ductile Cast Iron

MECHANICAL ASSESSMENT CRITERIA OF SPENT FUEL ASSEMBLIES BASKET DESIGN. Christian Kuschke Viktor Ballheimer Frank Wille Steffen Komann

USE OF THE MASTER CURVE APPROACH FOR THE DYNAMIC TOUGHNESS CHARACTERIZATION OF PRESSURE VESSEL STEELS

SOME ISSUES USING THE MASTER CURVE CONCEPT

Fundamental Study on Impact Toughness of Magnesium Alloy at Cryogenic Temperature

Fracture Mechanics experimental tests (ASTM standards and data) 2/2

Recent experiences in mechanical design assessment of spent fuel and HLW casks by Competent Authority in Germany

Subject Index. STP 1207-EB/Dec. 1994

Fractomechanical Properties of As-Cast and Austempered SG Cast Iron Between -40 C and +20 C

ME 207 Material Science I

ENGINEERING MATERIAL 100

26. Irradiation Induced Mechanical Property Changes: Hardening and Embrittlement

Fracture Mechanism of Ferritic Ductile Iron under Instrumented Impact Load at Low Temperatures

2067-1d. Joint ICTP/IAEA Workshop on Irradiation-induced Embrittlement of Pressure Vessel Steels November 2009

Compression characteristics of spheroidal graphite cast iron pipe members

Strain Rate and Temperature Insensitiveness of Notch-bend Strength for High Si Ductile Cast Iron

MECHANICAL PROPERTIES

APPLICATION LIMITS OF LOW-DUCTILE CAST IRON FOR RADIOACTIVE WASTE CONTAINERS

Introduction to Joining Processes

The micro-mechanisms of failure of nodular cast iron

EFFECT OF MATERIALS HETEROGENEITIES ON MICROSTRUCTURE AND MECHANICAL PROPERTIES AT IRRADIATED STATE

THE MECHANICAL PROPERTIES OF STAINLESS STEEL

MECHANICAL PROPERTIES AND TESTING TECHNIQUES

MECHANICAL PROPERTIES OF AN ULTRAFINE GRAINED C-MN STEEL

FIBER REINFORCED ROUND PANELS SUBJECTED TO IMPACT LOADING

BFF1113 Engineering Materials DR. NOOR MAZNI ISMAIL FACULTY OF MANUFACTURING ENGINEERING

Assessment of Plastic Flow and Fracture Properties with Small Specimen Test Techniques for IFMIF-Designed Specimens

26. Irradiation Induced Mechanical Property Changes: Hardening and Embrittlement

Mechanical behavior of crystalline materials - Stress Types and Tensile Behaviour

OXIDATION EFFECTS ON THE STRENGTH AND FRACTURE TOUGHNESS OF THE SELECTED NUCLEAR GRAPHITE GRADES AT 600 C. Abstract

Ductile and Brittle Fracture of 1018 Steel and. 304 Stainless Steel Using Charpy Impact Test. Eman Mousa Alhajji. North Carolina State University

FEATURES ON THERMAL FATIGUE OF FERRITE MATRIX DUCTILE CAST IRON

MATERIALS SCIENCE-44 Which point on the stress-strain curve shown gives the ultimate stress?

True Stress and True Strain

Fracture Behaviour of Three-layer PE-HD Pipe

CE 221: MECHANICS OF SOLIDS I CHAPTER 3: MECHANICAL PROPERTIES OF MATERIALS

Fracture toughness characterization of ductile phase containing in-situ

TI Typical HDPE raw material and pipe test methods EDITION 0607 PAGE 1/10

APPLICATION OF INSTRUMENTED CHARPY METHOD IN CHARACTERISATION OF MATERIALS

Fatigue Crack Paths in Ferritic-Perlitic Ductile Cast Irons

Zanardi Fonderie S.p.A. INFORMATIONAL SHEET ON AUSTEMPERED DUCTILE IRON - ISO JS/ and ISO JS/ RT -

ISO INTERNATIONAL STANDARD. Metallic materials Determination of plane-strain fracture toughness

APPLICATION OF MASTER CURVE METHODOLOGY IN THE DUCTILE TO BRITTLE TRANSITION REGION FOR THE MATERIAL 20MnMoNi55 STEEL

Chapter 14 Fracture Mechanics

Effect of Ti on Charpy Fracture Energy and Other Mechanical Properties of ASTM A 710 Grade B Cu-Precipitation-Strengthened Steel

ME 354, MECHANICS OF MATERIALS LABORATORY FRACTURE

MECHANICAL PROPERTIES AND TESTS. Materials Science

MAE 171A MECHANICAL ENGINEERING LABORATORY Materials Testing Laboratory Week 1 - LINEAR ELASTIC FRACTURE MECHANICS

Evaluation of Crashworthiness for SAE Materials under Ductile to Brittle Transition Temperature (DBTT)

IMPACT CHARACTERIZATION OF POLYMER COMPOSITES BASED ON PEEK AND CARBON FIBRES

Fracture Toughness of SE(B) Specimens of Steel in the Presence of Splitting. Pablo J. Lara Melcher, Enrique M. Castrodeza*

Available online at Procedia Engineering 00 (2009) Procedia Engineering 2 (2010)

Tensile/Tension Test Fundamentals

Effect of orientation and loading rate on the toughness transition curve of a ship steel

The Weibull Stress Parameters Calibration upon the Toughness Scaling Model between Cracks Having Different Constraint

3. A copper-nickel diffusion couple similar to that shown in Figure 5.1a is fashioned. After a 700-h heat treatment at 1100 C (1373 K) the

In-situ Heating and Cooling of Charpy Test Specimens 2

High strength fine grained structural steel. Quenched and tempered. Product description. 890 a product brand of Dillinger 1/6

High strength fine grained structural steel. Quenched and tempered. Product description. 965 a product brand of Dillinger 1/6

Stainless steel properties for structural automotive applications

ME 354, MECHANICS OF MATERIALS LABORATORY MECHANICAL PROPERTIES AND PERFORMANCE OF MATERIALS: CHARPY V-NOTCH IMPACT*

Workshop Practice TA 102

ACCELERATED THRESHOLD FATIGUE CRACK GROWTH EFFECT POWDER METALLURGY ALUMINUM ALLOY

SIGNIFICANCE OF DWT TESTING FOR LINE PIPE SAFETY

EN 1563:2012. Founding - Spheroidal Graphite Cast Irons Sfero Dökme Demir Standardı Teknik İrdelemesi Met.Y.Müh.Seyfi Değirmenci

Evaluation of the Fracture Parameters for SA Grade 70 Material

Influence of Grain Size on the Ductile Fracture Toughness of Ferritic Steel

Determination of the crack propagation direction of fractured ductile cast iron based on the characteristic features of the surface

RECOMMENDATIONS FOR OBTAINING SAMPLES OF CASTING PARTS MECHANICAL CHARACTERISTICS FUNDICIONES FUMBARRI-DURANGO. 15/04/2013 Rev.

Properties of Various Malleable Iron Powder Grades François Chagnon, Julie Campbell-Tremblay and Maryam Moravej

ME -215 ENGINEERING MATERIALS AND PROCESES

MECHANICS OF MATERIALS. Mechanical Properties of Materials

BRITTLE-TO-TOUGH TRANSITION IN TOUGHENED POLYPROPYLENE COPOLYMERS

POLITECNICO DI TORINO Repository ISTITUZIONALE

Prediction of fatigue crack propagation in aluminum alloy with local yield strength gradient at the crack path

Abstract. 1. Introduction

Quality of ductile iron

Standard Test Method for Linear-Elastic Plane-Strain Fracture Toughness K Ic of Metallic Materials 1

SURFACE VEHICLE STANDARD

Recent Developments in Through-Process Modelling of Aluminium Die-Castings

C. T. Liu Air Force Research Laboratory AFRRL/PRSM 10 E. Saturn Blvd. Edwards AFB CA

Steel Castings in Architecture PDH Code: AIA A781 AISC G295

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Characteristics affecting each stage of fatigue fracture

LABORATORY EXPERIMENTS FOR ASSESSING THE DETECTABILITY OF SPECIFIC DEFECTS BY ACOUSTIC EMISSION TESTING

The Production Technology of a Modern Material for Heavy Automotive Vehicles - A Compacted Graphite Iron (C.G.I.)

Introduction. 1. Testing procedure. 1.1 Specimen shape

11/2/2018 7:58 PM. Chapter 6. Mechanical Properties of Metals. Mohammad Suliman Abuhaiba, Ph.D., PE

Material properties of old steel bridges

Marc King. Hiler Industries LaPorte, IN

Static strength and High and Low-Cycle Fatigue at room temperature 1/2

STUDY OF SENT SPECIMENS WITH A TILTED NOTCH TO EVALUATE DUCTILE TEARING IN SPIRAL WELDED PIPELINE APPLICATIONS

Transcription:

INVESTIGATIONS ON THE DYNAMIC FRACTURE TOUGHNESS OF HEAVY-SECTION DUCTILE CAST IRON FOR TRANSPORT AND STORAGE CASKS Karsten Müller, Wolfram Baer and Peter Wossidlo, Department of Materials Engineering, Federal Institute for Materials Research and Testing (BAM), D-1225 Berlin, Germany ABSTRACT In consideration of the specific demands required for heavy-section ductile cast iron (DCI) for transport and storage casks the fracture mechanics research programme of BAM is focused on a systematic material characterization under static and dynamic loading conditions with respect to such parameters as microstructure, test temperature, sample size and loading rate. In the present study, ductile cast iron from an original DCI container with a wide variety of microstructure was investigated in order to determine the materials fracture toughness under dynamic loading conditions in the temperature range from -5 C to +22 C using three-point bending specimens with thicknesses of 14 mm and 15 mm, respectively. In contrast to static fracture behavior, the fracture toughness values of thick-walled DCI at higher loading rates show a remarkable reduction with decreasing temperature between +22 C and -5 C and a significant shift of the transition range from -4 C up to +22 C. On the other hand, the lower bound fracture toughness value used in the design code for transport and storage casks of DCI in Germany was confirmed for dynamic loading conditions by these first investigations using large specimens. Furthermore, at present, BAM works on a research program which comprises systematic investigations of the mechanical and fracture mechanical behavior of heavy section DCI at elevated loading rates. INTRODUCTION For more than twenty years ductile cast iron has been used very successfully for spent fuel casks in Germany. During this period the mechanical behavior of hundreds of containers has been investigated. Based on the BAM acceptance criteria for transport and storage containers, material specifications for DCI were established [1-3]. Now, new developments in cask design as well as efforts to extend the application limits require further investigations, especially in the field of fracture mechanical assessment of DCI at elevated loading rates. The materials toughness of DCI in terms of fracture mechanics characteristics is strongly influenced by microstructural parameters, especially the pearlite content as well as size, morphology and distribution of graphite nodules in the ferritic matrix. Furthermore, it has to be taken into account that in large DCI castings the microstructure is often not homogeneously distributed over the wall thickness. The International Atomic Energy Agency (IAEA) standard requires that containers certified for transport have to withstand hypothetical accidents, for example, a 9 meter free drop onto an essentially unyielding target at the lowest service temperature of -4 C without the loss of radioactive contents [4]. Therefore, under these accident conditions, the influence of strain rate at the crack tip on the material behavior has to be considered within design and safety analysis of containers and relevant material characteristics have to be provided.

INVESTIGATED NODULAR CAST IRON MATERIAL The nodular cast iron investigated in this study was taken from a container which had not totally fullfilled the required material specifications. Due to the cooling conditions in this large casting the microstructure was not homogeneously distributed over the wallthickness. The investigated specimens represent a wide variety of microstructure in terms of pearlite content of the matrix as well as size and distribution of the graphite nodules. Therefore, the mechanical properties vary either, as it can be seen from Figure 1. The materials strength, given by the,2 %-offset yield strength, R p,2, seems to be on a comparabel level for pearlite contents not exceeding 2 %. However, an increasing amount of pearlite results in reduced ductility values. As expected, an increase in loading speed leads to higher strength values. Concerning the ductility, the limited available data does not indicate a clear influence of the loading speed. 6 dynamic 3 dynamic quasi-static quasi-static R p,2 [N/mm²] 4 2 A [%] 2 1 1 2 3 Pearlite [%] 1 2 3 Pearlite [%] Figure 1, Yield strength, R p,2, and ultimate elongation, A, of DCI as a function of pearlite content at T = 22 C under quasi-static and dynamic (ε 1 1² s -1 ) loading conditions, respectively. EXPERIMENTAL PROCEDURE The fracture mechanical investigations included the testing of large (thickness 14 mm) and small (thickness 15 mm) single edge bend specimens (SE(B)) at elevated loading rates. A schematic outline and characteristic dimensions of the specimens are given in Figure 2. Prior to testing, all specimens were fatigue precracked providing initial a /W ratios of.5. The experimental determination of fracture toughness values using SE(B)14 bend specimens was carried out in a test stand for shock loading, Figure 3. The test stand is operated by a servohydraulic test cylinder of 1 kn maximum force and 4 m/s maximum speed. In the fracture mechanical tests a maximum force of 7 kn was reached at an impact speed of 2.5 m/s. As shown in Figure 3, the specimens were instrumented with a set of foil strain gauges as well as crack extension sensors in the ligament area. By means of this instrumentation, the crack initiation could reliably be deduced and dynamic fracture toughness values were determined. Within the analysis of the results the requirements of ASTM E 182 standard [5] for rapid loading K Ic determination were adopted and met so that

valid dynamic fracture toughness values K Id were determined. The average stress intensity rate, K, was about 5 1 4 MPa m/s. Specimen geometry SE(B)15 specimen SE(B)14 specimen Thickness B [mm] 15 14 Width W [mm] 3 28 Length L [mm] 16 135 Mechanical crack starter notch M [mm] 1 112 Initial crack length a [mm] 15 14 Span S [mm] 12 112 Figure 2, SE(B) specimen dimensions Figure 3, Test stand for experimental determination of dynamic fracture toughness values of DCI materials using SE(B)14 specimens, (Yellow arrows mark strain gages.) 25 mm 25 mm 1 mm

The experiments for the determination of dynamic crack resistance curves on SE(B)15 specimens were performed with a 75 kj Charpy impact testing machine using an instrumented 15 J hammer and by practising the low-blow multiple specimen technique, Figure 4. Within these configuration impact speeds in the range of 1 to 2 m/s were realised. By analysis of the registered force - deflection curves dynamic crack resistance curves were deduced by application of the J-integral concept. Dynamic crack initiation toughness values JIc were determined from these dynamic J-R curves based on the regulations of ASTM E 182 standard. Pendulum impact direction Figure 4, Experimental determination of dynamic crack resistance curves of DCI materials using SE(B)15 specimens RESULTS AND DISCUSSION The fracture toughness values of ductile cast iron at elevated loading rates show a remarkable decrease with decreasing temperature between +22 C and -5 C (Figure 5, Table 1). This material response describes the transition behavior of dynamic fracture toughness of DCI in dependence on the test temperature. In the upper transition range of fracture toughness towards ambient temperature elastic-plastic material behavior gains growing influence. At test temperatures of -4 C and -5 C the lower shelf of fracture toughness - characterised by fully linear-elastic material behavior and brittle fracture - is almost reached. It should be stressed that in the investigated temperature range all fracture mechanics characteristics of the SE(B)14 specimen met the requirements for valid KIc or KId values, respectively.

Fracture Toughness, K Id [MPa m] 15 1 5 Ductile Cast Iron Pearlite content at ¼B B ¾B 6-1 % 18-21 % -6-4 -2 2 4 Temperature [ C] Figure 5, Dynamic fracture toughness of DCI as a function of temperature and pearlite content at test temperatures from 5 C to +22 C and loading rate K 5 1 4 MPa m/s, SE(B)14 specimens. Table 1, Fracture mechanics values of DCI under impact loading conditions, SE(B)14 specimens, loading rate K 5 1 4 MPa m/s. Temperature T [ C] Dynamic fracture toughness K Id [MPa m] Pearlite content ± s [%] at ¼B B ¾B -5 21 ± 6, 46 21 ± 6,6 56 18 ± 1,6 56-4 9 ± 3,3 62 7 ± 3, 58 8 ± 3,7 61-2 8 ± 3,6 73 8 ± 3,3 65 9 ± 3,7 66 1 ± 4,8 111 22 6 ± 3,6 11 At static loading conditions, the transition region where ductile fracture changes to brittle fracture is supposed to be between -8 C and -1 C for small specimens [6], and for larger thicknesses between -4 C and -8 C as pictured in Figure 6. In Figure 6, the results of the present investigations show that in comparison to quasi-static loading conditions the transition range is shifted to higher

temperatures between about -4 C and +22 C due to the elevated loading rates. The levels of fracture toughness values in the lower and upper shelf are nearly equal to those of static loading conditions. Nevertheless, there should be a certain increase in thoughness in the upper shelf region as a result of increased material strength in the case of dynamic loading. 14 Ductile Cast Iron 12 Fracture Toughness [MPa m] 1 8 6 4 2 quasi-static: K 1-1 MPa m/s) C(T)1 dynamic: K 5 1 4 MPa m/s S(E)B 14 SE(B)14 28 135 mm³ Pearlite content 1-5 % 6-1 % 18-22 % 6-1 % 18-21 % -12-1 -8-6 -4-2 2 4 Temperature [ C] Figure 6, Fracture toughness behavior of ductile cast iron as a function of test temperature and loading rate (specimen dimensions and loading rate are noted in the figure), [2, 3]. Fracture mechanics characteristics of DCI are required for structural safety analysis within the container design and - with respect to the relevant material specification in case of irregularities of the cast iron quality - for production control and quality assurance programs. In the latter case, the fracture mechanical evaluation procedure is restricted to the results of relatively small specimens which can be machined from samples taken directly from the container without totally destroying the component. Therefore, smaller bend type specimens of SE(B)15 geometry, Figure 2, were investigated in the present study. Due to the elastic-plastic fracture behaviour of these specimens dynamic crack resistance curves could be determined and crack initiation toughness values J Id could be deduced. If required, these data can be converted to toughness values in terms of fracture toughness, K, according to ASTM E 182, for instance. Figure 7 shows that both, the crack initiation values, J Id, as well as the fracture resistance curves, J d - a, are strongly affected by the pearlite content. Increasing pearlite content leads to lower crack resistance. The same way, a decrease of the test temperature results in lower fracture toughness as indicated in Figure 8 for ferritic DCI.

J d -Integral [kj/m²] 2 15 1 Ductile Cast Iron Construction Line Pearlite content [%] 1 6 12 2 J Id [kj/m²] 76 6 6 45 5,2 mm Offset Line,5 1 1,5 2 2,5 3 Crack Extension, a [mm] Figur 7, Crack resistance behavior of DCI under impact loading conditions as a function of pearlite content at ambient temperature: Low-blow test with v 1 m/s, SE(B)15 specimens, regression according to ASTM E 182 (definition of J Id similar to J Ic at static loading). J d -Integral [kj/m²] 2 15 1 Ductile Cast Iron Pearlite content 1 % Construction Line Temperature [ C] + 22-2 J Id [kj/m²] 76 51 5,2 mm Offset Line,5 1 1,5 2 2,5 3 Crack Extension, a [mm] Figure 8, Crack resistance behavior of ferritic DCI under impact loading conditions as a function of test temperature: Low-blow test with v 1 m/s, SE(B)15 specimens, regression according to ASTM E 182 (definition of J Id similar to J Ic at static loading).

SUMMARY AND OUTLOOK In comparsion to static test results an increasing loading rate is predominantly responsible for a higher transition temperature and the change from elastic-plastic to linear-elastic material behavior in ductile cast iron. The lower bound fracture toughness value of 5 MPa m used for DCI in the design code for transport and storage casks in Germany was confirmed by the first investigations at elevated loading rates. However, further research work requires the determination of dynamic fracture toughness values especially on small-size specimens and a statistical assessment procedure according to the materials behavior. At present, BAM works on a research programme which comprises systematic investigations of the mechanical and fracture mechanical behavior of heavy section DCI at elevated loading rates taking parameters into account like variation of microstructure, test temperature, sample and component size and loading rate. REFERENCES [1] D. Aurich, R. Helms and K. Wieser, Das sicherheitstechnische Konzept der BAM für Spärogußbehälter (The BAM safety concept for nodular cast iron containers), Amts- und Mitteilungsblatt der Bundesanstalt für Materialforschung und -prüfung (BAM), 17 (1987), Nr. 4, pp. 657-663. [2] B. Rehmer, H.D. Kühn, S. Weidlich, H. Frenz, BAM production control programme for containers for transport and storage of nuclear materials, RAMTRANS, 6 (1995), Nos. 2/3, pp. 25-219. [3] K. Müller and B. Rehmer, Dynamic fracture toughness of ductile cast iron for transport and storage casks Proc. of the Annual Meeting on Nuclear Technology 2, Bonn, Germany, Mai 23-25, 2, pp. 69-612. [4] International Atomic Energy Agency, Regulations for the safe transport of radioactive material, IAEA-Safety Standard Series No. ST-1: Requirements, Vienna, 1996 edition. [5] ASTM E 182-99, Standard Test Method for Measurement of Fracture Toughness, American Society for Testing and Materials, July 1999. [6] J.A. Smith, D. Salzbrenner, K. Sorenson and P. McConnel, Fracture mechanics based design for radioactive material transport packagings - Historical review, Sandia Report SAND-98-764, Sandia National Laboratories, Albuquerque, New Mexico, April 1998.