Fixations dans les maçonneries

Similar documents
European Technical Assessment. ETA-17/0237 of 15/05/2017. General Part. Technical Assessment Body issuing the. Instytut Techniki Budowlanej

ETA-11/0141 of 08/08/2016. European Technical Assessment. General Part. Technical Assessment Body issuing the. Instytut Techniki Budowlanej

European Technical Approval

European Technical Assessment. ETA-13/0088 of 20/03/2018. Egzemplarz archiwalny. General Part. Instytut Techniki Budowlanej

European Technical Assessment. ETA-12/0398 of 29/12/2017. General Part. Instytut Techniki Budowlanej. Technical Assessment Body issuing the

ETA-07/0291 of 30/06/2014. European Technical Assessment. Draft. General Part. Technical Assessment Body issuing the. Instytut Techniki Budowlanej

ETA-13/0584 of 24/09/2014. European Technical Assessment. General Part. Technical Assessment Body issuing the. Instytut Techniki Budowlanej

Designated according to Article 29 of Regulation (EU) No 305/2011 and member of EOTA (European Organisation for Technical Assessment)

English translation prepared by CSTB - Original version in French language. FRIULSIDER Via Trieste,1 I San Giovanni al Natisone (UDINE) ITALIE

English translation prepared by CSTB - Original version in French language

(English language translation, the original version is in French language) SORMAT LYT. SORMAT OY Harjutie 5 FIN Rusko Finlande.

English translation prepared by CSTB - Original version in French language. Throughbolt TX

Designated according to Article 29 of Regulation (EU) No 305/2011 and member of EOTA (European Organisation for Technical Assessment)

English translation prepared by CSTB - Original version in French language. Throughbolt PTB-ETA7-PRO

ITW Construction Products Italy S.r.l. V.le Regione Veneto, PADOVA (PD) ITALIEN. V.le Regione Veneto, PADOVA (PD) ITALIEN

(English language translation, the original version is in French language) SPIT SAS route de Lyon F BOURG-LES-VALENCE France

English translation prepared by CSTB - Original version in French language

English translation prepared by CSTB - Original version in French language

English translation prepared by CSTB - Original version in French language POWERS PB-PRO-S

English translation prepared by CSTB - Original version in French language. Smart expansion anchor types H / T / K

English translation prepared by CSTB - Original version in French language

European Technical Assessment. ETA-11/0336 of 17 July English translation prepared by DIBt - Original version in German language.

European Technical Assessment ETA-14/0454 of 11/12/2014

English translation prepared by CSTB - Original version in French language. PoSB-PRO Power Screwbolt

European Technical Assessment ETA 14/0075 of 14/04/2014

European Technical Assessment ETA 14/0077

European Technical Assessment ETA-14/0453 of 11/12/2014

Designated. according to. Article29 of. Regulation (EU) Nº 305/2011. English translation prepared by IETcc. Original version in Spanish language

European Technical Assessment ETA-15/0288 of 17/06/2015

English translation prepared by CSTB - Original version in French language SPIT MULTI-MAX. SPIT SAS Route de Lyon Bourg-Les-Valence FRANCE

Designated. according to. Article29 of. Regulation (EU) Nº 305/2011. English translation prepared by IETcc. Original version in Spanish language

Designated. according to. Article29 of. Regulation (EU) Nº 305/2011. English translation prepared by IETcc. Original version in Spanish language

European Technical Assessment ETA-16/0865 of 08/11/2016

from 01/02/2018 English translation prepared by CSTB - Original version in French language

Designated. according to. Article29 of. Regulation (EU) Nº 305/2011. English translation prepared by IETcc. Original version in Spanish language

English translation prepared by CSTB - Original version in French language. OUTIFIX 82, rue Saint Lazare Paris FRANCE

English translation prepared by CSTB - Original version in French language. Tecfi S.p.A. SS Appia km 193 Pastorano (CE) 81050, Italia

European Technical ETA-04/0023 Assessment of 17 October 2017 General Part

In der Stockwiese Bad Laasphe DEUTSCHLAND. Manufacturing plant EJOT Herstellwerk 1, 2, 3 und 4 manufacturing plant EJOT 1, 2, 3 und 4

English translation prepared by CSTB - Original version in French language

English translation prepared by CSTB - Original version in French language. SPIT EPCON C8 rebars

European Technical Assessment. ETA 15/0226 of General Part TCM400PE, TCM600PE. Trade name of the construction product

English translation prepared by CSTB - Original version in French language

Declaration of Performance

Declaration of Performance No1109-CPD-0080 According to the Regulation EU No 305/2011

English translation prepared by CSTB - Original version in French language. FM753 Crack

Designated. according to. Article29 of. Regulation (EU) Nº 305/2011. English translation prepared by IETcc. Original version in Spanish language

DECLARATION OF PERFORMANCE. No EN

System Components. Grades. General Information Installation Information

Declaration of Performance No. DPGEB1006 v2.1

European Technical Approval

English translation prepared by CSTB - Original version in French language SPIT EPOMAX. Société SPIT Route de Lyon F BOURG-LES-VALENCE FRANCE

SVM-PSC Polyester resin for use in concrete

English translation prepared by CSTB - Original version in French language. Stud anchor BOAX-FMC

(English language translation, the original version is in French language) SIKA Services AG Tüffenwies 16 CH-8048 Zürich, Switzerland

English translation prepared by CSTB - Original version in French language. Injection system DeWalt PURE110-PRO

Sormat ITH-Pe PRODUCT DATA SHEET. ITH-Pe - POLYESTER BASED RESIN STYRENE FREE. Polyester based injection resin, styrene free. ITH 165 Pe art.

European Technical Assessment. ETA-15/0540 of Member of. General part

EJOT Chemical Anchoring Systems. High strength anchoring of threaded resin studs into masonry blocks, cracked and non-cracked concrete

ETA-13/0058 Assessment

ETA-13/0772. fischer Bolt anchor FXA. Klaus-Fischer-Straße Waldachtal DEUTSCHLAND. fischerwerke. of this assessment EAD

English translation prepared by CSTB - Original version in French language. Simpson Strong-Tie ZAC. Les 4 chemins Sainte-Gemme-la-Plaine France

Declaration of Performance

European Technical Approval

R-KEM II with Threaded Rods for Masonry

Injection System Batifix VIFIX V. BATIFIX Z.A. La Gravière FAREINS FRANCE. Plant France 1

European Technical Approval ETA-08/0058


European Technical Assessment ETA-10/0422 of 08/01/2016

DECLARATION OF PERFORMANCE

R-KEM II with Threaded Rods for Masonry

(English language translation, the original version is in French language) AT-HP Stainless Steel

English translation prepared by CSTB - Original version in French language. Injection System ZETACHEM EPX 30 / 41

English translation prepared by CSTB - Original version in French language PB-PRO & PB-SS-PRO

European Technical Approval ETA-11/0126. RAWL SafetyPlus

European Technical Approval

Declaration of Performance No1109-CPD-0079 According to the Regulation EU No 305/2011 HXE01 - HXE02 - HXE12 - HXE85 - HXE03

(English language translation, the original version is in French language) SPIT FIX3. Société Spit Route de Lyon F BOURG-LES-VALENCE France

European Technical Approval

Pintakäsittely Mitat Tuotenro. Eurooppalainen arviointiasiakirja

Declaration of Performance

English translation prepared by CSTB - Original version in French language

SINGLE ANCHOR USE FOR NON-CRACKED CONCRETE

Type or serial number or any other element allowing identification of the construction product as

SUPERPLUS M8-M16. The undercut fixing system that does not require a special setting tool. FUNCTION BENEFITS

European Technical Approval

European Technical Approval ETA-11/0344

Permissible loads of a single anchor in cracked normal concrete (concrete tension zone) of strength class C20/25 ( B25) Permissible tensile load

(English language translation, the original version is in French language) SPIT V-MIX + Société SPIT Route de Lyon F BOURG-LES-VALENCE France


DECLARATION OF PERFORMANCE

PACTORep Fixer EASF AVAILABILITY. Working Hardening 3h 2h 1h30 1h Anchor Installation Resistance Admissible loads

Construction. Universal anchoring adhesive. Product Description 1 1/7. Product Data Sheet Edition _1 Sika AnchorFix -S

European Technical Assessment ETA-17/0346 of 07/06/2017

Trutek TCM380 PRO. Trutek Fasteners Polska Al. Krakowska 55 Sekocin nowy Rasxyn Poland T:

Injection Adhesive VM-PY

System Components. Grades. General Information. Installation Information Design Information Material Information Ordering Information

(English language translation, the original version is in French language) SPIT EPOMAX A4. Société SPIT Route de Lyon F BOURG-LES-VALENCE France

Type or serial number or any other element allowing identification of the construction product as

Declaration of Performance No. DPGEB1018 v2

Transcription:

Fixations dans les maçonneries AGRÉMENT TECHNIQUE EUROPÉEN ETE - 11/0506 ETAG 029 RÉSINE MÉTACRYLATE SANS STYRÈNE 300 ml DS I.N.G. Fixations - ZI de Chassende BP 90168 43005 Le Puy en Velay cedex France Tél: +33 (0)4 71 05 59 03 - Fax: +33 (0)4 71 09 35 46 - ing.fixations.info@orange.fr - www.ingfixations.fr Membre Adhérent n 586

INSTYTUT TECHNIKI BUDOWLANEJ PL 00-611 WARSZAWA ul. Filtrowa 1 tel.: (+48 22) 825-04-71 (+48 22) 825-76-55 fax: (+48 22) 825-52-86 www.itb.pl Designated according to Article 29 of Regulation (EU) No 305/2011 and member of EOTA (European Organization for ) Member of www.eota.eu European Technical Assessment General Part Egzemplarz archiwalny of 21/02/2017 (English language translation the original version is in Polish language) Body issuing the European Trade name of the construction product Instytut Techniki Budowlanej Product family to which the construction product belongs Injection anchors for use in masonry Manufacturer Manufacturing plant France Plant 1 Francois Inglese Ing Fixations BP168, Z.I. De Chassende F-43005 Le Puy-En-Velay, Cedex France This European contains This European is issued in accordance with regulation (EU) No 305/2011, on the basis of 14 pages including 3 Annexes which form an integral part of this Assessment Guideline for European Technical Approval of "Metal injection anchor for use in masonry", ETAG 029, Edition April 2013 used as European Assessment Document (EAD) This version replaces issued on 08/03/2012

Page 2, issued on 21/02/2017 This European is issued by the Body in its official language. Translations of this European in other languages shall fully correspond to the original issued document and shall be identified as such. Communication of this European, including transmission by electronic means, shall be in full. However, partial reproduction may only be made with the written consent of the issuing Body. Any partial reproduction has to be identified as such.

Page 3, issued on 21/02/2017 Specific Part 1 Technical description of the product The injection system is a bonded anchor (injection type) consisting of a mortar cartridge with injection mortar, a perforated sleeve and an anchor rod with hexagon nut and washer size M10. The steel elements are made of zinc coated carbon steel. The anchor rod is placed into a drilled hole filled with injection mortar and is anchored via the bond between steel element, injection mortar and masonry and mechanical interlock. The illustration and the description of the product are given in Annex A. 2 Specification of the intended use in accordance with the applicable European Assessment Document (EAD) The performances given in Annex C are only valid if the anchor is used in compliance with the specifications and conditions given in Annex B. The provisions made in this European are based on an assumed working life of the anchor of 50 years. The indications given on the working life cannot be interpreted as a guarantee given by the producer or Technical Assessment Body, but are to be regarded only as a means for choosing the right products in relation to the expected economically reasonable working life of the works. 3 Performance of the product and references to the methods used for its assessment 3.1 Performance of the product 3.1.1 Mechanical resistance and stability (BWR 1) Essential characteristic Characteristic resistance for tension and shear loads Characteristic resistance for bending moments Displacements under shear and tension loads Reduction Factor for job site tests (β-factor) Edge distances and spacings Performance Annex C1 Annex C1 Annex C1 Annex C2 Annex C2 3.1.2 Safety in case of fire (BWR 2) Essential characteristic Reaction to fire Resistance to fire Performance Anchorages satisfy requirements for Class A1 No performance assessed 3.1.3 Hygiene, health and the environment (BWR 3) Regarding dangerous substances there may be requirements applicable to the products falling within its scope (e.g. transposed European legislation and national laws, regulations and administrative provisions). In order to meet the provisions of the Construction Products Regulation, these requirements need also to be complied with, when and where they apply.

Page 4, issued on 21/02/2017 3.1.4 Safety and accessibility in use (BWR 4) For basic requirement safety in use the same criteria are valid as for basic requirement mechanical resistance and stability. 3.1.5 Sustainable use of natural resources (BWR 7) No performance assessed. 3.1.6 General aspects relating to fitness for use Durability and serviceability are only ensured if the specifications of intended use according to Annex B1 are kept. 3.2 Methods used for the assessment The assessment of fitness of the anchor for declared intended use in relation to the requirements for mechanical resistance and stability and safety in use in the sense of the Basic Requirements 1 and 4 has been made in accordance with the ETAG 029 Metal injection anchor for use in masonry. 4 Assessment and verification of constancy of performance (AVCP) system applied, with reference to its legal base According to the Decision 97/177/EC of the European Commission the system of assessment and verification of constancy of performance (see Annex V to Regulation (EU) No 305/2011) given in the following table is applied. Product Intended use Level or class System Metal injection anchors for use in masonry Fixing and/or support to masonry, structural elements (which contribute to the stability of the works) or heavy units such as cladding as well as installation 1 5 Technical details necessary for the implementation of the AVCP system, as provided in the applicable European Assessment Document (EAD) Technical details necessary for the implementation of the AVCP system are laid down in the control plan deposited in Instytut Techniki Budowlanej. For the type testing the results of the tests performed as part of the assessment for the European shall be used unless there are changes in the production line or plant. In such cases the necessary initial type testing has to be agreed between Instytut Techniki Budowlanej and the notified body. Issued in Warsaw on 22/08/2016 by Instytut Techniki Budowlanej

Page 5, issued on 21/02/2017 Schema of the anchor in use Product description Installation conditions Annex A1

Page 6, issued on 21/02/2017 Mortar cartridges and applicator guns: Cartridge Applicator gun coaxial cartridge: 150 ml side-by-side cartridge: 235 ml 345 ml 825 ml coaxial cartridge: 280 ml 380 ml 400 ml 410 ml two-layers cartridge with plastic insert 150 ml 165 ml 170 ml 280 ml 300 ml 410 ml Special mixing nozzle: Product description Injection system Annex A2

Page 7, issued on 21/02/2017 Anchor rods Perforated plastic sleeve Product description Threaded rods and sleeve Annex A3

Page 8, issued on 21/02/2017 Table A1: Materials Part Designation Material 1 Chemical mortar Epoxyacrylate, styrene free resine mortar, hardener, additive 2 Anchor rod Carbon steel class 5.8, EN ISO 898-1, zinc plated 5 µm, EN ISO 4042 3 Washer Carbon steel, zinc plated 5 µm, EN ISO 4042 4 Hexagonal nut Carbon steel class 5, EN ISO 898-2, zinc plated 5 µm, EN ISO 4042 5 Perforated sleeve Polyethylene Product description Materials Annex A4

Page 9, issued on 21/02/2017 Anchorages subject to: Static and quasi-static loads Specification of intended use Base materials: Perforated ceramic blocks masonry (use category c), according to Annex B2. Mortar strength class of the masonry M2,5 at minimum according to EN 998-2:2010. For other perforated, ceramic blocks the characteristic resistance of the anchor may be determined by job site tests according to ETAG 029, Annex B under consideration of the β-factor according to Annex C2, Table C4. Temperature range: Tb: -40 C to +80 C (max. short term temperature +8 0 C and max. long term temperature +50 C). Use conditions (Environmental conditions): Structures subject to dry internal conditions (zinc coated steel). Use categories: c base material. w/d installation and use. Design: Verifiable calculation notes and drawings are prepared taking account the relevant masonry in the region of the anchorage, the loads to be transmitted and their transmission to the supports of the structure. The position of the anchor is indicated on the design drawings. The anchorages are designed in accordance with to the ETAG 029, Annex C, design method A under the responsibility of an engineer experienced in anchorages and masonry work. Installation: Dry internal structures. Hole drilling by rotary drill mode. Anchor installation carried out by appropriately qualified personnel and under the supervision of the person responsible for technical matters of the site. Intended use Specifications Annex B1

Page 10, issued on 21/02/2017 Table B1: Base material Perforated ceramic blocks (LD) type HLz, 12/09 N + F, class 15 (tested f b 18 N/mm 2 ) density q m 900 kg/m 3 Type of base material Standard EN 771-1 Intended use Type of brick and dimensions Annex B2

Page 11, issued on 21/02/2017 Table B2: Installation parameters of anchor rods with perforated sleeves Size M10 Size of rod d nom [mm] 10 Size of sleeve d s x l s [mm] 16 x 85 Drill hole diameter d o [mm] 16 Depth of drilled hole to deepest point h 1 [mm] 90 Effective anchorage depth h ef [mm] 85 Torque moment T inst [Nm] 4 Table B3: Maximum processing times and minimum curing times of Résine SP, DS resine mortar Masonry temperature [ C] Maximum processing (working) time [Minutes] Minimum curing (loading) time [Minutes] -5 50 90 5 18 30 15 8 20 25 3 20 35 2 20 Intended use Installation parameters, processing and curing times Annex B3

Page 12, issued on 21/02/2017 1 2 6 3 7 4 8 5 9 1 Drill the hole to the correct diameter and depth using a rotary machine 2 Remove the sealing cap 3 Screw on the mixing nozzle 4 Place the cartridge into the applicator gun 5 Dispense the first part ( 10 cm) to waste until an even color is achieved 6 Introduce the sleeve of suitable dimensions 7 Insert the nozzle to the end of the sleeve and inject the resin so long till the sleeve will fill into 100% 8 Insert the anchor, slowly with a slight twisting motion into the sleeve 9 Remove excess resin and leave the fixing until minimum curing (loading) times has elapsed Intended use Installation instruction Annex B4

Page 13, issued on 21/02/2017 Table C1: Characteristic tension load and shear load values Brick parameters: Density q [kg/m 3 ] Compressive strength f b [N/mm 2 ] Sleeve Anchor size Effective anchorage depth h ef [mm] Characteristic resistance N Rk [kn] 1) Characteristic resistance 2), 3) V Rk [kn] q 900 f b 12 16 x 85 M10 85 3,50 1,25 Partial safety factor ϒ M = 2,5 4) 1) For design according to ETAG 029, Annex C N Rk = N Rk,p = N Rk,b = N R,pb = N Rk,s 2) For design according to ETAG 029, Annex C V Rk = V Rk,b = V Rk,c = V Rk,s 3) V Rk calculated according to ETAG 029 (Edition April 2013), Annex C, Section C.5.2.2.5 4) In absence of other national regulations Table C2: Characteristic bending moment Characteristic bending moment M Rk,s [Nm] 37,4 Partial safety factor γ Μs 1,25 1) 1) if no other national regulations exist Table C3: Displacements under tension and shear load N [kn] δ NO [mm] δ N [mm] V [kn] δ VO [mm] δ V [mm] 1,3 0,06 0,25 2,0 0,9 2,4 Performances Characteristic tension load and shear load values, characteristic bending moment, displacements Annex C1

Page 14, issued on 21/02/2017 Table C4: β-factor for job site tests according to ETAG 029, Annex B Temperature β-factor -40 o C to 80 o C 0,86 x 0,94 = 0,81 Table C5: Edge distances and spacings Size d nom + Φd x L [mm] s cr [mm] s min [mm] c min [mm] 10 + Φ16 x 85 l unit, max l unit, max c min 100 l unit, max maximal length of masonry unit Performances β-factor, edge distances and spacings Annex C2