INSULATORS NEW. See page J-4 for more information.

Similar documents
DISTRIBUTION SILICONE INSULATORS Deadend / Suspension 15 kv to 69 kv

Transmission Silicone Insulators Line Post 69 kv to 230 kv

Polymer Suspension Insulators 69kV to 765kV

GROUP A. Polymeric Insulators.

Energy Division Insulators

TRANSMISSION & DISTRIBUTION SILICONE INSULATORS InterPhase Spacers 15 kv to 400 kv

INSULATORS. Industry photo: should be a the same image as larger industry photo. Either a different crop or different angle.

CS type composite silicone insulators up to 750 kv overhead lines for all pollution of the atmosphere levels

Veri*Lite Deadend, Suspension & Line Post Insulators for 15-69kV Applications

DESIGN TEST REPORT. GAMMA Insulators 6184R-70 ANSI Class 55-3 Pin Type Insulator..

DESIGN TEST REPORT. GAMMA Insulators 7061R-70 ANSI Class 55-5 Pin Type Insulator.

DESIGN TEST REPORT. GAMMA Insulators 6183R-70 ANSI Class 55-4 Pin Type Insulator.

TEMPORARY PROTECTIVE GROUNDING EQUIPMENT

30-SDMS-01 SPECIFICATIONS FOR LOAD BREAK SWITCH

Polymer Station Post Insulators for 69 to 345 kv Applications

Data Sheet 110kV TD123II dry type outdoor termination

United States Department of Agriculture Rural Development Rural Utilities Service. RUS Bulletin 1724E-220

Power Systems 2 ELE3015. Lecture 1: Transmission Lines

General Requirements. Technical Specifications for Insulators of Transmission Lines

TRANSMISSION NEW PROJECTS DEPARTMENT TRANSMISSION LINES TOWER DESIGN AND SPECIFICATIONS SECTION ATHENS - GREECE SPECIFICATION TR-1

GSCH004 Rev /10/2016

8. Hydrophobicity classification guide STRI guide 1.92/1 9. Radio interference characteristics of overhead power lines and high-voltage equipment

TEMPERED GLASS INSULATORS

GUJARAT ENERGY TRANSMISSION CORPORATION LTD. TECHNICAL SPECIFICATIONS

SPECIFICATION FOR 11 & 33kV COMPOSITE INSULATORS Part 1: Pin Type

Notes Changed note Date. 1 (A) Changed template 09 / 07 / 2008

Composite insulators. Features. Sicat 8WL3068, 8WL3078 and 8WL3088 for overhead contact line systems. siemens.com/rail-electrification

Specification for Polymer Disc Insulator

General Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Substation Insulators (63 kv- 400 kv)

5 / 8" AFL NO. ULTIMATE STRENGTH (LBS.) APPROX. WEIGHT EACH (LBS.) APPLICATION SCE , HIBUS Double Suspension R1"

Composite Insulator Components

094: 2000 CEB STANDARD. MEDIUM VOLTAGE PIN INSULATORS & HARDWARE (12kV & 36 kv) CEYLON ELECTRICITY BOARD SRI LANKA

COMPOSITE INSULATORS

SPECIFICATION FOR POLYMER DISC INSULATOR

FIJI ELECTRICITY AUTHORITY BIDDING DOCUMENT

Veri*Lite Silicone Rubber Line Post Insulators for 15-72kV Applications

Polymer Post Insulators for 46 to 500kV Applications

IEEE T&D Insulators 101

Pins Insulator. Composite/Polymers Insulators

093 : 2000 CEB STANDARD MEDIUM VOLTAGE PIN POST INSULATORS AND HARDWARE CEYLON ELECTRICITY BOARD SRI LANKA

Height Pole Care and Maintenance

NATIONAL ELECTRIC POWER COMPANY (NEPCO) TENDERNO. 9/2013 FOR THE SUPPLY OF INSULATORS AND FITTINGS FOR DOUBLE AND QUADRUPLE CIRCUITS 132 kv OHTL's

Sediver composite suspension insulators

Technical Specification for Helical Fittings for Overhead Power Lines

HIGH VOLTAGE INSULATORS. By JP Holtzhausen. Glass. Bushings & hollow core insulators. Cap & pin insulators

Prototype Test Report ANSI C29.17 Quadri*Sil Line Post Insulators 2.5 Dia. Rod HPS Silicone rubber R

FOREWORD SCOPE NORMATIVE REFERENCES DEFINITIONS REQUIREMENTS... 4

TECHNICAL SPECIFICATION FOR 11KV COMPOSITE INSULATORS (SILICON RUBBER HOUSED)

Sediver toughened glass insulators for HVAC applications. Experts & Pioneers USA

Effect of UV-Rays and Salt Contamination on 33kV Silicon Composite Insulators

Data Sheet 110kV TP123-II Porcelain Insulator Outdoor Termination

TECHNICAL SPECIFICATIONS FOR. 11 KV, 45 KN, 320 mm. Creepage Distance, Long rod (B&S) type Composite (Polymer) Insulators

POST AND DISC INSULATOR

PART-II. TECHNICAL SPECIFICATIONS FOR 11 KV, 45KN, 320 Creepage Distance, Long rod (B&S) type Composite (Polymer) Insulator.

Technical Specification for Outdoor Porcelain Station Post Insulators

Polymer and FRP Technology - An Alternative to Conventional Porcelain for Future Power Sector

33-SDMS-02 SPECIFICATIONS FOR

SECTION N EQUIPMENT FOR SUBSTATION MAINTENANCE

11 KV, 45KN, 320 Creepage Distance, Long rod (B&S) type Composite (Polymer) Insulator

Suspension clamps. Contents. General Oscillating and trunnion type suspension clamps forged.. 3. Oscillating type suspension clamps cast...

HARYANA VIDYUT PRASARAN NIGAM LIMITED. TECHNICAL SPECIFICAION FOR POLYMER INSULATOR STRINGS FOR 220KV / 132KV/66KV TRANSMISSION LINES

BIDDING DOCUMENT FOR. Supply of Galvanized Steel Tubular Poles, 11KV Polymer Insulators and ACSR Conductors under Saubhagya Scheme

FIBRE REINFORCED PLASTICS IN HIGH VOLTAGE APPLICATIONS

Development of Composite Line Spacers for Distribution Lines

11KV PORCELAIN INSULATORS AND FITTINGS

CHAPTER 6 HIGH VOLTAGE ELECTRICAL TESTING RESULTS

Application Note FS Series PV Module Mounting

MGVCL/MM/1043/13-14/11 KV Disc Insulators (Porcelain)

Insulating Covers. Insulators: EPBI: Light Weight Polymeric Post Insulator. EPBI: Light Weight Polymeric Stand Off Insulator

TECHNICAL SPECIFICATION FOR 11 POST INSULATORS, 11 KV & 33 KV PIN INSULATORS AND 11 KV, B&S TYPE 45 KN & 70 KN DISC INSULATORS.

Design of MO Surge Arresters with Polymeric Housings

Technical Specifications for 11 KV, 45KN, 320 mm. Creepage Distance, Long rod, (B&S) type Composite (Polymer) Insulator

TECHNICAL SPECIFICATION SECTION- SWITCHYARD ERECTION REVISION -08

Composite Solutions for the Automotive Industry

Specification No. CSC- XXIX/DH/UH/P&D/

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY SPECIFICATIONS FOR HIGH PRESSURE SODIUM LUMINAIRES, CUTOFF TYPE

Heavy Wall Heat Shrinkable Tubing 5-7. Flame Retardant Heavy Wall Heat Shrinkable Tubing 8. Heat Shrinkable Ends Caps 9

and FIBERGLASS FOAM AND HOLLOW CORE BUILDING PANELS

SPECIFICATION FOR HT PIN (11KV & 22KV) AND 11KV DISC. INSULATORS:

1. Filled-in Supply Record Form.

INSULATOR REQUERIMENTS:

ENGINEERING SPECIFICATION EE SPEC

SAFETY LINE TEMPORARY PROTECTIVE GROUNDING EQUIPMENT

TM Series Induced Draft Cooling Tower Specifications

ISO Rules Part 500, Facilities Division 502, Technical Requirements Section Bulk Transmission Technical Requirements

Outdoor High Voltage Non-Ceramic Insulators

Technical Specification for 11 KV, 5KN, 340 Creepage Distance Pin type Composite (Polymer) Insulator with rod

NEW! PUPI Fiberglass Transmission & H-frame Products

ECONOMIC ANALYSIS OF 400 KV TRANSMISSION TOWERS WITH CROSS ARMS INSULATORS

SPECIFICATION FOR DISC INSULATORS (Standard Type)

ElectroStop. Monolithic Isolation Joints INNOVATIVE ENGINEERING FOR CORROSION PROTECTION

SURGE ARRESTERS kv in silicone shield

Design features - Polymer-housed arresters, PEXLIM

fire Charcoat Charcoat IC Passive Protection

SUPERIOR CAL-SHIELDS Features & Benefits FAST

IBC Compliant Seismic Rated Isolators

TECHNICAL SPECIFICATION FOR 11 KV & 33 KV POST INSULATORS, 11 KV & 33 KV PIN INSULATORS AND 11 KV, B&S TYPE 45 KN & 70 KN DISC INSULATORS.

TECHNICAL SPECIFICATION OF ELECTRICAL MATERIALS. Polymer Insulators

Artificial Accelerated Ageing Test of Silicone Rubber Housing Material for Lightning Arrester

SPECIFICATION FOR HT PIN (11KV & 22KV) AND 11KV DISC. INSULATORS: -

Transcription:

INSULATORS

INSULATORS NEW Improved 23613 Dead End/Suspension Insulator Salisbury s Improved 23613 Dead End/Suspension Insulator has aluminum end fittings. These new end fittings create a lightweight product that is easier to handle and provides a 15,000 pound ultimate tensile strength. The new aluminum end fittings withstands corrosion better than the previous galvanized steel SI series insulators, adding to the life of the insulator. 100% proof testing ensures trouble-free installation. The insulator was tested in accordance with ANSI C29 and IEC1109. See page J-4 for more information. L-2 Insulators. www.salisburybyhoneywell.com

SALVAR & Silicone Insulators SALVAR & Silicone Composite Insulators combine the technologies of fiberglass reinforced rod, metal fittings and our extensive knowledge of elastomeric insulation to produce a high quality composite insulator. Since 1980 thousands of SALVAR and Silicone Insulators have been installed by utilities worldwide in a variety of environments. Continued outstanding performance is proof of their superior quality and design. Design: Two designs are used to manufacture SALVAR and Silicone Insulators: Unibody and Modular. Unibody Design insulators are one-piece injection molded directly to the rod and sealed to the end fittings with a bead of silicone to give the insulator high dielectric strength and protect it from all environmental conditions. This design is used for standard distribution dead end/suspension insulators. Fiberglass Rod: A high quality fiberglass reinforced rod is the core of every insulator with ultimate mechanical strength at least twice the maximum working load. End Fittings: Standard distribution dead/end suspension units are supplied with clevis and tongue fittings meeting ANSI C29-2 specifications. Ball, socket, and eye fittings are also available. All are made of hot dipped galvanized high strength carbon steel and have an ultimate tensile strength rating of 15,000 pounds. All end fittings on dead/ end suspension insulators are attached by compression. Every insulator is proof tested to verify the crimp. Unibody insulators have end fittings sealed with silicone to eliminate any possibility of moisture or contamination from reaching the fiberglass rod. 101 E. Crossroads Pkwy., Ste. A Bolingbrook, IL 60440 toll free ph (USA):877.406.4501 toll free fax (USA):866.824.4922 ph:630.343.3800 L-3

SI Series Silicone Insulator & New Aluminum Option 15kV to 35kV Dead End/Suspension, Tongue & Clevis The SI Series of Silicone Insulators features a silicone formulation weathershed material. Salisbury combined the excellent hydrophobic and electrical qualities of silicone with an optimum weathershed design and corrosion resistant fiberglass rod to produce a state-of-theart insulator which meets or exceeds industry requirements. The insulators were tested in accordance with ANSI C29 and IEC1109. End fittings are hot dipped galvanized high strength carbon steel, providing a 15,000 pound ultimate tensile strength. 100% proof testing ensures trouble-free installation. RUS Accepted. Unibody insulators have end fittings sealed with silicone to eliminate any possibility of moisture or contamination from reaching the fiberglass rod. NEW Salisbury s Improved 23613 Dead End/ Suspension Insulator has aluminum end fittings. These new end fittings create a lightweight product that is easier to handle and provides a 15,000 pound ultimate tensile strength. The new aluminum end fittings withstands corrosion better than the previous galvanized steel SI series insulators, adding to the life of the insulator. 100% proof testing ensures trouble-free installation. This insulator includes the same silicone weathershed material as th SI Series. 23613 The insulator was tested in accordance with ANSI C29 and IEC1109. 9501U-SI 9502U-SI 23613 9503U-SI Class DS-15 DS-28 DS-28 DS-35 No. of Weathersheds 4 6 6 8 Length-in ( m ) 13.5 (.34 ) 17.5 (.45 ) 17.5 (.45 ) 21.3 (.54 ) Dia. of Weathersheds-in ( mm ) 3.8 ( 97 ) 3.8 ( 97 ) 3.8 ( 97 ) 3.8 ( 97 ) Leakage Distance-in ( m ) 17.1 (.44 ) 26(.66 ) 26(.66 ) 35.1 (.89 ) Dry Arc Distance-in ( m ) 8.4 (.22 ) 12.13 (.31 ) 12.13 (.31 ) 16 (.41 ) Flash Over Voltage Critical Impulse, Pos 173 217 217 258 Critical Impulse, Neg 250 310 310 340 Dry, 60 Hz 97 145 145 168 Wet, 60Hz 67 115 115 137 Radio Influence Test, kv Ground 15 25 25 25 Max RIV-1000kHz µv 1 1 1 1uV Ultimate Strength lbs. 15,000 15,000 15,000 15,000 FRP Rod Dia.-in ( mm ).73 ( 18.63 ).73 ( 18.63 ).73 ( 18.63 ).73 ( 18.63 ) Typ. Appl-kV, Ø-Ø 15 27 27 35 Net Weight ea.-lbs. ( kgs ) 2.6 ( 1.20 ) 3.1 ( 1.39 ) 2.2 (.99 ) 3.5 ( 1.57 ) L-4 Insulators. www.salisburybyhoneywell.com

The 9502L-EP Silicone Insulator 27kV The 9502L-EP Silicone Insulator combines two essential characteristics: PERFORMANCE - The 9502L-EP is the only composite insulator manufactured as a replacement for two 10 (254mm) porcelain disks. Installation is limited to horizontal dead-end applications only. INNOVATION - Unlike any other insulator on the market, the unique shed design of the 9502L-EP minimizes the material content without compromising electrical or dimensional requirements. End fittings are hot dipped galvanized high strength carbon steel. Must be used as a dead end insulator only. RUS Accepted. 9502L-EP No. of Weathersheds 5 Length-in ( m ) 11.5 (. 29 ) Dia. of Weathersheds-in ( mm ) 5 ( 127 ) Leakage Distance-in ( m ) 22 (.56 ) Electrical Critical Impulse 189 Ratings Dry, 60 Hz 116 kv Wet, 60 Hz 92 Radio Test--kV Ground 20 Influence Max RIV--1000Hz µv 1 Typ. Appl--kV, Ø-Ø 27 Ultimate Strength-SML- lbs / kn 15000 / 70 Net Weight ea.-lbs ( kgs ) 2.8 ( 1.3 ) 101 E. Crossroads Pkwy., Ste. A Bolingbrook, IL 60440 toll free ph (USA):877.406.4501 toll free fax (USA):866.824.4922 ph:630.343.3800 L-5