Measure the Crack Instead of Construction Vibrations

Similar documents
COMPARISON OF MICRO-INCH IN-PLANE AND OUT-OF-PLANE RESPONSE OF CRACKS TO BLAST VIBRATION AND WEATHER

APPENDIX NFII Naples, Florida (2009) Phase II - Quarry Blasting

Albuquerque, New Mexico (2012) Vibratory Roller Compaction Abeel_2012

Instrumental Detection of a Climatologically-Induced Cosmetic Crack in Wall Covering

Effect of Blast Design on Crack Response

RESPONSE OF UN-CRACKED DRYWALL JOINTS AND SHEETS TO BLAST VIBRATION AND WEATHER

Autonomous Crack Measurement for Comparison of Vibratory Compaction Excitation and Climatological Effects

Response of Historic Structure to Long-term Environmental and Construction Vibration Effects

Structure Response to Trench and Road Blasting

Blast Induced Micrometer Response of Cracks in Concrete Block Structures

Planning and Growth Management Committee. Chief Building Official and Executive Director, Toronto Building. P:\2007\\Cluster B\BLD\CBO Office\PGM004

VIBRATION AND STRUCTURAL INTEGRITY

Bat Monitoring, Fort Leonard Wood, Missouri: Sound and Seismic Effects

Ambient Vibration Testing of Three Unreinforced Brick Masonry Buildings in Vancouver, Canada

4.4 Vibration. Table 4.24 FTA and Swiss Standard SN a Construction Vibration Damage Criteria

Keywords: damaging vibrations, construction activities, Forensic Engineering

Subject: Ellis Commons Senior Housing Blasting Noise and Vibration Evaluation, City of Perris

October 1, Re: Contract ID A Plans, Proposal, EBS, Questions & Answers October 8, 2013 Letting

Preliminary Analysis of Potential Vibration Impact to Old Hickory Lock & Dam from Proposed Quarry Operations

Preliminary Analysis of Potential Vibration Impact to Old Hickory Lock & Dam from Proposed Quarry Operations

INVESTIGATION ON TECHNIQUES TO CONTROL STRUCTURAL DAMAGE DUE TO BLASTING ACTIVITIES

GUIDELINES FOR CONSTRUCTION VIBRATIONS. How Much Rattle Is Too Much? JULY/AUG GROUND VIBRATIONS. By Sandy Figuers, PE, EG, GP, HG

Analysis III Mold & Moisture Research

EVALUATION OF NONLINEAR STATIC PROCEDURES FOR SEISMIC DESIGN OF BUILDINGS

A New Approach to Blasting Induced Ground Vibrations and Damage to Structures

Ventilation and Cooling

The entire document shall be read and understood before proceeding with a test.

OVERVIEW OF PROCEDURE 2A

TABLE 3-24 SUMMARY OF EXISTING AMBIENT NOISE MEASUREMENT RESULTS

Project Findings: Appendix 2

OVERVIEW OF PROCEDURE 2B

SIGNIFICANCE OF SHEAR WALL IN FLAT SLAB MULTI STORIED BUILDING - A REVIEW. Vavanoor, India

PERIODS OF REINFORCED CONCRETE FRAMES DURING NONLINEAR EARTHQUAKE RESPONSE

Analysis and experimental studies of building glass facade

DEMOLITION BY USE OF EXPLOSIVES

7. BASIC GROUND-BORNE VIBRATION CONCEPTS

Response of Test House to Vibroseis Vibrations and Environmental Forces

Fundamentals of Jointing for Volume Change in Concrete

Maintenance of NDE Websites

Design of bridges with modular expansion joints for prevention of earthquake-induced girder poundings

The entire document shall be read and understood before proceeding with a test.

Testing Packaged Products Weighing More Than 150 Lbs.

CYCLIC BEHAVIOR OF AN INNOVATIVE STEEL SHEAR WALL SYSTEM

THE SEISMIC PERFORMANCE OF FLOORING SYSTEMS EXECUTIVE SUMMARY. Dene Cook 1

CITY OF TORONTO. BY-LAW No

EXPERIMENTAL INVESTIGATION ON THE INTERACTION OF REINFORCED CONCRETE FRAMES WITH PRECAST-PRESTRESSED CONCRETE FLOOR SYSTEMS

What Is The True Cost of Final Finish Tire Testing?

Investigation of Wind Projectile Resistance of Insulating Concrete Form Homes. by Ernst W. Kiesling, Ph.D., P.E. Russell Carter, BSCE, EIT

THE STRATA UNIT May 25, 2008

Investigating Tile Failures on Wood-Frame Floor Systems 1 by Frank Woeste and Peter Nielsen

Direct Measurement of Inter-Story Drift Displacements of Scale Model

Performance Monitoring of a Short-Span Integral-Abutment Bridge Using Wireless Sensor Technology

Vibration monitoring of long bridges and their expansion joints and seismic devices

Analysis of Seismic Waves Generated by Blasting Operations and their Response on Buildings

CSE Engineering, Inc.

Super pave Mix Design (Permanent Deformation of Flexible Pavement)

APRIL 2017 UNDER CONSTRUCTION

EFFECTS OF STRONG-MOTION DURATION ON THE RESPONSE OF REINFORCED CONCRETE FRAME BUILDINGS ABSTRACT

Nonlinear Dynamic Analysis a Step Advance

Effects of Mine Blasting on Residential Structures

SCHEDULE 17 Cultural Heritage Monitoring Program

SMART STRUCTURES: FIBER-OPTIC DEFORMATION AND DISPLACEMENT MONITORING

Eidem Farm Brooklyn Park, MN

Draft Environmental Impact Statement 3-59 Chapter 3 Affected Environment

FULL-SCALE VERIFICATION TEST OF DYNAMIC RESPONSE CONTOROL TECHNIQUES FOR STRONG EARTHQUAKES

STRUCTURAL EVALUATION OF DOVER ELEMENTARY SCHOOL WEST CONTRA COSTA UNIFIED SCHOOL DISTRICT (WCCUSD)

STRUCTURAL EVALUATION OF WASHINGTON ELEMENTARY SCHOOL WEST CONTRA COSTA UNIFIED SCHOOL DISTRICT (WCCUSD)

Earthquakes 101. Instructor: Stanton Smith, P.E.

Engineering Geology and Seismology. Structural Geology

Optimizing Building Energy Performance

Seismic Design and Performance of Metal Buildings

Vibration-Induced Fatigue Failure of Discharge Bottle Fitting Connections A Case Study

MOISTURE CONDITIONS IN WALLS AND CEILINGS OF A SIMULATED OLDER HOME DURING WINTER

Vibration Generated Due To Pile Driving In Water And Soil

WESTSIDE PURPLE LINE EXTENSION PROJECT, SECTION 2 ADVANCED PRELIMINARY ENGINEERING Contract No. PS

STRUCTURAL EVALUATION OF TARA HILLS ELEMENTARY SCHOOL WEST CONTRA COSTA UNIFIED SCHOOL DISTRICT (WCCUSD)

Integrated Performance Based Design of Tall Buildings for Wind and Earthquakes

Field Commander. Overview. Operations. Custom Solution. Building Startup/Shutdown

Warwick FRP Bridge: Design and Performance

The entire document shall be read and understood before proceeding with a test. ISTA 3B Page 1 of 35

North Hanover Township School District North Hanover Township, New Jersey

This document is an OVERVIEW ONLY

Testing and analysis of masonry arches subjected to impact loads

Development and Application of Seismic Isolation and Response Control of Buildings in Japan

Applications (Rubber/Rubber) (Acrylic/Acrylic)

Shaking Table Model Test of a HWS Tall Building

EFFECT OF FLUID VISCOUS DAMPERS IN MULTI-STOREYED BUILDINGS

Second Revised Seismic Certification of WRK Series 19-inch Multi-Bay Rack Enclosures installed with Seismic Anchoring Kit

WHAT YOU SHOULD KNOW ABOUT CONTROLLED BLASTING LAS VIRGENES MUNICIPAL WATER DISTRICT WATER STORAGE TANK PROJECT

APPENDIX D EXISTING ROADWAY NOISE, AIR QUALITY AND GROUND VIBRATION ANALYSIS

LIFE-CYCLE MONITORING AND MAINTENANCE OF BRIDGES: THE ROLE OF REMOTE SHM SYSTEMS

QBE Restoration Program Highlights

REPORT ON VIBRATION MONITORING GRANGEGORMAN CAMPUS CENTRAL & EAST QUAD, DUBLIN 7

STATISTICAL ENERGY ANALYSIS OF A HIGH SPEED ELEVATOR CAB AND FRAME

RESILIENT INFRASTRUCTURE June 1 4, 2016

Determination of damage location in RC beams using mode shape derivatives

Soil-Structure Interaction (SSI) Testing Facility and Capabilities at Lehigh University

Lighthouse Engineering, L.L.C.

Literature Review of Wood-frame Structure Tests

Spatial Inspection of Steel Pile Driving Operations using Laser Scan Data

Transcription:

Measure the Crack Instead of Construction Vibrations by Charles H. Dowding, Ph.D., P.E. Figure 1 - Typical instrumented room with detail of crack and sensor Construction is omnipresent in modern-day America. It's the sound and vibration of a nation scrambling to keep up with its burgeoning population. In most states, allowable constructioninduced ground motions range from 0.5 to 1.0 inches per second (in/sec) and under certain conditions up to 2.0 in/sec. However, ground motion as low as 0.02 in/sec can be perceived, and repeated motions throughout the day as low as 0.1 in/sec can cause annoyance. Even responsible construction activity produces motions that may startle people. Sharing close quarters with housing, businesses, and industrial complexes, construction activity often becomes a lightening rod for more complaints than it deserves. Many people incorrectly believe that construction vibration causes damage to their homes or buildings. What these people tend to focus on are cracks like that in Figure 1.

Because many people interpret the response of buildings in their own terms, they tend to believe that if the vibration can be felt, it must be having a negative effect on the structure. The fact is, cosmetic cracking from construction vibrations has not been observed below peak particle velocities of 0.8 in/sec. Currently, complaints are addressed by measuring peak ground motions outside the structure with a blasting seismograph. These measured peak ground motions are then compared with a standard developed by the federal or state government. Motions that people truly believe are harmful usually turn out to be below the government standard. These standards, developed by some unknown government officials or researchers, are met with skepticism. Furthermore, it's difficult to convince skeptics that the "silent crackers" - temperature and humidity - produce more cracking than a phenomena that is felt and heard. MEASURE THE CRACK All homes are cracked to some extent. Advances in sensor technology and computerized data acquisition now make it possible to address fears of vibration-induced cracking by directly measuring crack response. Relatively inexpensive systems to monitor both crack response and ground motion have been developed that involve the manual downloading of data on a periodic basis. These systems can be combined with telecommunications for display on the Internet. The public can then access the data, which increases their confidence in the information. Measuring the crack response directly has several advantages over the current approach of measuring ground motion. First, the response of the cracks that are the most visible to owners are directly involved. Second, ground motion complexities and their indirect relationship to damage are avoided. Third, and most important, crack response to vibratory events can be compared to that produced by long-term factors such as changes in the weather. A special dual-purpose sensor like that shown in Figure 1 can be placed across a crack to simultaneously measure long-term and vibratory changes in crack width. This direct measurement, termed "crack displacement" is simple to understand and requires no reliance upon empirical guidelines. HOUSE AND CRACK RESPONSE TO VIBRATIONS Crack measurement concepts are illustrated by the response of a wood-frame house in central Indiana subjected to repeated blasts from a nearby surfact coal mine. The house was heavily instrumented by the author to assess the effects of environmental changes (temperature, humidity, soil volume change, and frost heave, for example), and to compare them with those produced by blasting and human activity. The house was purchased from its owner, who had constructed two additions to the original midsection. Thus it was built of materials and was in a condition typical of many older houses. The house was vacant during testing. However, the vibration system was so sensitive it could detect the arrival of the cleaning service. A similar house has been instrumented on the Northwestern University campus and is linked to the Internet at http://www.iti.northwestern.edu/acm. Accessing this site allows observation of the response of cracks to changes in temperature and humidity, as well as occupant-induced motions.

The time history of response to a blast is shown in Figure 2. By comparing timing of the peaks, it can be seen that the initial higher frequency portion of the ground motion - "Long" (longitudinal), "Tran" (transverse) and "Vert" in figure 2 - produces the greatest velocity response (d1 and d2) at the center of an interior and an exterior wall, while the trailing lower frequency portion produces the largest super-structure response (d3 and d4) at the corner of the second story. Figure 2 - Time histories of ground motions, as well as house and crack response from a typical blast. Crack displacements on an exterior wall of the single story portion of the house (c10) are produced by both high and low frequency portions of the motions, whereas those at the corner of an interior doorway immediately below sotry (c7) are larger during the low frequency portion. All sensors were placed on the inside of the house. Regardless of the crack sensor location, the measurements research demonstrate a very important point about vibration-induced cracking displacement: Crack displacements do not necessarily result in permanent offset. As long as the ground motion is within allowable limits, the ground motion after it passes, excitation dies out and so does the building and crack response. Thus there is no residual or long-term impact because the crack width returns to its pre-blast opening. The same cannot be said for weather and other long-term effects.. WEATHER-INDUCED CRACKING

The same crack width sensors that responded to vibratory excitation were also able to detect response to changes in crack width caused by changes in temperature and humidity. Seasonal and weather front-induced variations in crack displacement can be seen in Figure 3, which compares crack displacements to outside humidity over an eight month period. Figure 3 - Comparison of displacement response of cracked tape joint (c7), un-cracked dry wall (c6) and un-cracked tape joint (c10) with changes in outside humidity.

Unusually large changes in humidity are circled in the lower graph of outside humidity for comparison with the corresponding displacement response of wall cracks, which are circled in the upper graph of crack displacement. The weather front-induced crack responses with a duration of about a week are equal and sometimes greater than the seasonal responses that have a length of several months. Three sensor positions were chosen to demonstrate the effects of differences in drywall detail wall deformation over an eight-month period. Position c6, the least responsive, is located on the middle of a continuous drywall sheet on an interior wall and did not span a crack or a joint between drywall sheets. Sensor c7 spans the most active drywall crack located at a tape joint between drywall sheets on an exterior wall. WEATHER AND VIBRATION DISPLACEMENTS COMPARED In Figure 4, environmental and vibration-induced displacements are compared directly for transducer location c7 in units of mils (l/l000th of an inch or 0.025 millimeters). Transducer c7 showed the most response to both environmental and vibration effects as a function of time, and most clearly shows the relative effect of each. Figure 4 - Comparison of long-term (silent) weather induced crack response to that from blasting. The weather effects, measured two to three times daily, appear as a continuous function. Blasting events occurred on average less than once per day and appear as individual point events marked by the plus signs. During the eight months of observation, mining advanced toward the test house as reflected by the increase in blast-induced displacement.

The greatest blast-induced vibration during this period was 0.75 in/sec. Despite this significant vibration level, the induced crack displacement was a good deal less than the average change produced by the passage of a significant weather front. The maximum weather induced deformation was some 3.5 times that of the maximum produced by blasting. Thus, approximately once a week this house is naturally subjected by changes in the weather to deformations that produce crack displacements equal to those produced by ground motions of at least 0.5 in/sec. Every week, season by season, houses deform significantly more than they would from a typical blast. The difference between environmental and vibration phenomena is that the weather effect occurs slowly and without noise. It is therefore undetectable by the home owners and neighbors. But with new crack displacement techniques, owners can see the effects of weather-induced cracking with their own eyes. They can also see that vibration-induced cracking may not be "all that it's cracked up to be." # # # Charles H. Dowding is a professor of Civil Engineering at Northwestern University. His continuing work in automated micro-inch crack measurement is sponsored by the Infrastructure Technology Institute at Northwestern University, which is funded by a grant from the U.S. Department of Transportation. Chuck can be reached at c-dowding@northwestern.edu. # # #