Cellulose Insulation Products. Date: Submitted to: Submitted by: Job Reference: Job Name

Similar documents
SUBMITTAL FORM All GreenFiber Products Date: Submitted to: Submitted by: Job Reference: Job Name: GREENFIBER PRODUCT ATTRIBUTES

Product Guide Specification

Standard practice for installing cellulose building insulation

Product Specification

Save up to 40% on utility bills with Nu-Wool Premium Cellulose Insulation

Acoustical Surfaces, Inc.

JM SPRAY FOAM: A BETTER PRODUCT FROM A BETTER PARTNER

MATERIALS MATTER. Legendary innovation in every detail of every product. JM SPRAY FOAM: A BETTER PRODUCT FROM A BETTER PARTNER

12 MOST COMMONLY ASKED QUESTIONS ABOUT HOME INSULATION

Premium Blown-in Insulation System

Quality Insulation Installation (QII) Insulation Installation (Page 1 of 4)

PREP + INSULATION. DISCLAIMER: These tools are for illustrative purposes only and

EcoTouch Insulation with PureFiber Technology

Residential Product Selector Guide

New Approaches to Energy Efficiency & Green Building. Who is Icynene Inc.? World-Wide Distribution. The Icynene Insulation System

SECTION THERMAL INSULATION

Distinguish your homes with spray foam insulation from a name you can trust.

SECTION LOOSE-FILL INSULATION. 1.1 SUMMARY A. Section Includes: 1. Loose-fill insulation // with vapor barrier // at attic floors.

About Insulation & R Value - cmhc.ca

2015 MICHIGAN UNIFORM ENERGY CODE Effective: February 8, 2016

Insulation: Comparing the Facts. vs. vs.

Open and Closed Cell Spray Foam Insulation

HPW Protocol Reference Manual

Air Infiltration & the Knauf Insulation EcoSeal

10 Steps to Save Energy in Your House

FRM B4-59 Rev No: Page: Of: Thermal Insulation Program Certification Report

5 Inspiring Home Projects That Add Value to Your Home

THERMAL BATT INSULATION COMFORTBATT. Thermal Batt Insulation for Residential & Commercial Construction.

FIBER GLASS INSULATION. Thermal. Acoustical. Fire Resistant. Moisture Control. Recycled Content. Formaldehyde-free. Air Control FIBER GLASS INSULATION

ENERTITE. More Than Just Insulation Low Density Insulation. Raising Performance To New Heights

Submittal Packages Detailed with Items and Reviewers

ENERGY SAVINGS FOR LIFE

Chapter 4: Insulation

Attic Floor Installation Instructions for Contractors

BUILDING INSULATION. Residential Product Guide

Master Specification ENERTITE by BASF Canada Inc. Section SPRAY POLYURETHANE FOAM INSULATION Page 1

Document Title: Doc No: FRM B4-59 Rev No: Page: Of: Thermal Insulation Program Certification Report

CertaSpray Foam Insulation. Your dream. Your insulation.

Truss Heel Heights and Energy Code Requirements. Overview Revised 2/17/2017

INSULATION SUCCESS WITH 2012 IECC DELAWARE. for Builders & Trades. Recommended Practices for Optimized Energy Savings

EASY$ TIP SHEETS. Energy Advice Saving Yukoners Money. Adding insulation

SECTION Blown Insulation THERMAL INSULATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

Retrofitting & Weatherizing

Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Chapter 19 - Interior Insulation

JUST THE FACTS! EcoTouch PINK FIBERGLAS Insulation The best choice for home energy savings

Weather Resistant Barrier

INSIDE WHY SPRAY POLYURETHANE FOAM INSULATION?

L77 INSULATION THAT WORKS AS HARD AS YOU DO PRO PROPINK INTRODUCING

CERTIFICATE OF FIELD VERIFICATION & DIAGNOSTIC TESTING (Page 1 of 8)

Thermal Bypass Checklist: How We Got There?

Design Professionals. We ll change the way you think about. Insulation and your Designs

THE PERFORMANCE INSULATION SYSTEM THAT DELIVERS CLIMATE ISOLATION CONTRACTORS

SECTION SPRAY FOAM INSULATION

The Optimal Solution for MidFloor Applications

INSULATION INSTALLATION

Knauf Insulation & Sealing System Q&A

Project Name: Enforcement Agency: Permit Number:

Foamed-in-place insulation Sprayed insulation. Spray Foam Insulation for Residential Building Envelope Insulation

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ELASTOCHEM SPECIALTY CHEMICALS, INC.

ESR-1826 Reissued May 1, 2009 This report is subject to re-examination in one year.

6747 Campobello Road Mississauga, Ontario, Canada

All of Alaska in Zone 7 except for the following Boroughs in Zone 8: Northwest Arctic. Yukon-Koyukuk. North Slope ADD INSULATION TO ATTIC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: RHINO LININGS CORPORATION

Premium Loose Fill Fiber Glass Insulation

City of High Point Airport Overlay District Noise Level Reduction Design Standards

Master Specification WALLTITE Eco v.3 by BASF Canada Inc. Section SPRAY POLYURETHANE FOAM INSULATION Page 1

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: NATURAL POLYMERS, LLC

Foil Back Gypsum Board

Prescriptive Checklist for the 2015 Washington State Energy Code

Boulder City NV Prepared by (Print Name) Signature Date

Cathedral Ceiling Applications

Knauf Data Sheet BI-DS Thermal/Acoustical Insulation

Town/City: State: Zip: Town/City: State: Zip: Phone: Cell: Phone: Cell:

Master Specification WALLTITE ECO v.2 by BASF Canada Inc. Section SPRAY POLYURETHANE FOAM INSULATION Page 1

1 Exam Prep Florida Building Code-Energy Conservation Edition Tabs and Highlights

Lock In Energy Savings For Life

WORKING SMART WITH FIBER GLASS, ROCK WOOL AND SLAG WOOL PRODUCTS

We Have a Better Way to Keep You Safe and Comfortable. ENERTITE Open-Cell Spray Polyurethane Foam Insulation

SECTION PRE-ENGINEERED BUILDING INSULATION

Charter Township of Washington

SPRAY FOAM INSULATION. Where Innovative Design Meets Sustainability

15402 Vantage Parkway East, Suite 322 Houston, Texas

Thermal/Acoustical Insulation. Data Sheet BI-RL-DS 05-18

Accella Polyurethane Systems, LLC

Questar ThermWise Duct Technical Specifications

2015 Michigan Residential Code Energy Worksheet for New Single-family Residential Building

General Contractor: Company Name: Location of Proposed Structure: Tax Map #: Lot #:

Building Envelope

2015 Michigan Residential Code Energy Worksheet for New Single-family Residential Building

THERMAL AND MOISTURE PROTECTION

An Introduction to Spray Foam Insulation

Chapter 1: Compliance

Where to Draw the Line with Thermal Boundaries

GUIDE SPECIFICATION: DUCT LINER

insulation guide CertainTeed fiber glass Insulation Guide Ask Your Local Retailer for These Other Top Quality CertainTeed Building Products

DIVISION: 07- THERMAL AND MOISTURE PROTECTION Section: Thermal Insulation REPORT HOLDER:

THERMAL INSULATION

InSuLATInG YouR WoRLd SInCE 1979

Transcription:

Submittal Form Cellulose Insulation Products Date: Submitted to: Submitted by: Job Reference: Job Name This submittal form is provided to assist you in specifying and selecting the proper GREENSHIELD Cellulose Insulation Product. Basic product descriptions and performance data are included. For additional information or technical assistance, please contact your local GREENSHIELD representatiive or call 866-476-3278. 10CPF-I-14v0 Page 1 of 5

PRODUCT DESCRIPTION MINIMUM THICKNESS Depth in inches THERMAL RESISTANCE @ 3.7 per inch R-VALUE GREENSHIELD Performance Cellulose Formulations Dry, natural organic insulation made from a combination of paper fibers, dry adhesive or binder with a borate based fire retardant chemical system 1.5 2.5 3.5 4.0 R-6 R-9 R-13 R-15 4.5 R-17 5.0 R-19 5.5 R-20 6.0 R-22 8.0 R-30 PRODUCT INFORMATION GREENSHIELD cellulose insulation is manufactured from recycled paper fiber and treated with a borate based fire retardant chemical system. GREENSHIELD provides superior thermal performance when compared to many other insulation products. GREENSHIELD performance cellulose can be used in vertical assemblies and attics for residential and commercial structures as well as cathedral ceilings, interior walls and between floors. When GREENSHIELD stabilized cellulose is used in an attic application, there should be no slope restrictions. GREENSHIELD insulation products are provided for dry installation processes and for moisture added installation processes. GREENSHIELD Loose Fill insulation is installed dry with universal application for attics, dense pack vertical walls, cathedral ceilings, retrofit attics and sidewalls, and between floor applications. May be available in retail outlets and used in the DIY market. GREENSHIELD Stabilized Attic insulation is installed with a small amount of moisture, which activates a binder that creates a strong monolithic fiber matrix. (The moisture added during installation is released within a short time after installation). The application requires less installed inches [less material] to achieve the same R-value compared to the dry installation process. Recommended installation by a professional contractor. GREENSHIELD Stabilized Sidewall is designed for vertical installations, typically new construction open vertical cavities, and is spray applied with a small amount of moisture that activates a binder that creates a strong fiber matrix that stabilizes the material in the wall cavity. (The moisture added during installation is released within a short time after installation). 10CPF-I-14v0 Page 2 of 5

o o Spray applied GREENSHIELD is typically installed at between 2.6 and 3.0 lbs. ft 3. Installed moisture will measure between 25% and 35%. Installed moisture will be a function of the climate and the builder production schedule. The moisture level for GREENSHIELD spray applied needs to be less than 25% before being covered. Installers of GREENSHIELD spray applied insulation should have a moisture management system in place to assure installations are within manufactures guidelines. The moisture management system should include an oversight protocol with a random sampling of installations the following day. R-value Where GREENSHIELD is installed dry in a vertical assembly, the installed density is typically between 3.0 and 3.5 lbs. ft 3. Managing installed density is important to ensure a stable and complete cavity installation without settling. Where GREENSHIELD is installed between floors or in a dense pack retrofit applications, installed densities will be between 3.0 and 3.5 lbs. ft 3. GREENSHIELD R-value has been tested to be 3.7 per inch. Cellulose has been shown to maintain its R-value even at extreme temperatures as compared to other blown-in insulation products. This characteristic is important for an attic installation where the unconditioned space can see temperatures as low as 15 20 F or as high as 140-160 F. Cellulose provides an excellent monolithic thermal separation between conditioned and unconditioned space. GREENSHIELD in a wall assembly is a complete cavity fill system. The complete cavity fill system is a performance based installation that eliminates the chances for gaps, voids, compressions, or misalignment that can occur with a standard batt installation. This complete cavity fill system completely fills the cavity including hard reaching places like behind wiring, plumbing runs, and electrical boxes. The GREENSHIELD full cavity installation system improves the effective R-value for the assembly because the insulation fills the entire cavity and remains in contact with the air barrier (dry wall) which is necessary for the insulation to be effective and perform to the stated R-value. Full cavity installation plus higher density installed product reduces air infiltration through the cavity; reduces energy loss; reduces sound typically carries with air; reduces exterior and interior nuisance noise; improves fire safety due to less air available for combustion in the event of a fire, and provides optimal energy performance for the homeowner. This means less cost to heat and cool and more homeowner comfort. SOUND Higher installed density and the full cavity fill system with GREENSHIELD helps to significantly improve the sound transmission across the assembly. This reduces exterior and interior nuisance noise from bonus rooms, media rooms, laundry rooms, attached garages, or plumbing chases. 10CPF-I-14v0 Page 3 of 5

FIRE SAFETY GREENSHIELD cellulose is treated with a borate based fire chemical system for fire retardancy. GREENSHIELD cellulose is constantly tested for fire retardant protection according to ASTM test methods for cellulose manufacture. All chemicals used are non-toxic, non-corrosive and will not irritate the skin. ENVIRONMENTAL RESPONSIBILITY GREENSHIELD is manufactured from post consumer paper fiber with a recycled content of approximately 80% or more. GREENSHIELD can be considered a part of any environmentally responsible program because of its recycled content and because (1) it reduces the demand for landfill space; (2) is reduces overall energy demand for buildings, (3) its process is virtually emissions free, and (4) it requires less energy to produce per pound of insulation. GREENSHIELD can be a critical component of many Green Building initiatives and Performance Building programs. GUARANTEE GREENSHIELD insulation is tested by 3 rd party certified laboratories to assure it meets the stringent performance standards and meets or exceeds national building code requirements. offers a written limited lifetime warranty to meet the strong standards for the industry and those standards as established by the federal government. CONSIDERATIONS GREENSHIELD performance cellulose should be installed according to ASTM C-1015. The material should not be installed where temperatures will exceed 194 F or in areas of excessive or continuous moisture. Cellulose should not be installed in spaces where it will come in contact with heat sources such as light fixtures, stove pipers, chimneys, etc., which are not rated for zero clearance from combustibles. TESTING GREENSHIELD has been tested and complies with ASTM C-739 and HHI-515-E. GREENSHIELD is class 1 fire rated GREENSHIELD conforms with CSPC Standard 16 CFR Parts 1209 and 1404 R-value has been tested at 3.7 per inch. HANDLING AND STORAGE No special handling is required. Storage in dry indoor location is recommended. To insure the integrity of the product and optimal performance, material should be used on a first-in first-out basis. Storage conditions can be ambient. EXPOSURE CONTROLS AND PERSONAL PROTECTION No specific controls are necessary. Good housekeeping and engineering controls should be in place to manage nuisance dust levels. If nuisance dusts levels are not maintained, use a NIOSH approved air purification respirator. If the working environment is excessively dusty, use ANSI approved eye protection equipment. 10CPF-I-14v0 Page 4 of 5

If skin is broken or sensitive gloves should be used. Provide normal and adequate ventilation Cellulose is listed / regulated by OSHA, Cal/OSHA and ACGIH as Particulates Not Otherwise Classified or as Nuisance Dust. PHYSICAL AND CHEMICAL PROPERTIES Gray odorless fiber Cellulose is not soluble. Chemical additive is soluble at a rate of ±4.7% @ 20 C ph is measured @ ±7.4 (20% solution @ 25 C) GREENSHIELD for Attic Applications Monolithic layer of separation Performance at extreme temperatures Superior attic separation from unconditioned space Less energy loss Less cost to heat and cool More Homeowner COMFORT GREENSHIELD preferred specification for every attic installation GREENSHIELD for Wall Applications Installed R-value Installed density Install visual comparison In contact with air barrier (without gaps, voids, misalignments) Less air infiltration Less nuisance noise (exterior or interior) Less energy loss Less cost to heat and cool Improved fire safety due to less air available for combustion Improved sound Improved Peace of Mind Improved COMFORT GREENSHIELD Vertical Wall Considerations PO Box 624 Elkin, NC 28621 Office: 866-476-3278 Fax: 336-527-4145 info@carolinafibers.com Manufacturing 145 Factory Street Ronda, NC 28670 Energy Upgrade Option Sound and Energy Upgrade Option Builder Sales Training Most effective Full Cavity Installation System GREENSHIELD is a high performance insulation product and should be considered for energy performance homes and Green / Sustainable projects. As with any construction material GREENSHIELD should be used in compliance with all applicable building codes, sound building science processes and installed in compliance with manufacturers specifications. 10CPF-I-14v0 Page 5 of 5