OSHA s Enforcement and Significant Changes in 2015 NFPA 70E. Presented by Doug Tellin Electrical Safety Specialists LLC.

Similar documents
OSHA s Enforcement and Significant Changes in 2015 NFPA 70E. Doug Tellin Title, Electrical Safety Specialists

NFPA 70E 2018 TOP CODE CHANGES

Setting up an electrical safety training program

110.2 Training Requirements.

NFPA 70E 2015 Changes

Arc Flash University, Session 2: NFPA 70E- 2012: Key Changes and Risk Reduction Strategies. Sponsored By:

NFPA 70E Compliance: A Systems Approach

Salisbury Assessment Solutions Electrical engineering services for a safe and compliant workplace

Sticklers for Safety. Sep 17, 2014Van Wilkins Electrical Construction and Maintenance

General Electrical Safety Awareness Course: E100

Electrical Safety ESWP and NFPA 70E Electrical Safe Work Practice

Is Your Electric Utility Prepared for the New Arc Flash Safety Regulation?

NFPA 70E Standard for Electrical Safety in the Workplace. EEI Safety and Health Meeting April 2010

What Are the Qualifications to Conduct Arc Flash Studies? Where Do You Begin?

electrical engineering division Arc Flash Study Planning Kit Everything You Need To Ensure The Success of Your Arc Flash Project

October 25 and 26, 2017

ENERGIZED ELECTRICAL WORK APPROVAL WORKSHEET INSTRUCTION August 2016

Implementing and Managing Electrical Safety Programs

Six Keys to Managing Workplace Electrical Safety

ELECTRICAL SAFE WORK PRACTICES

LOCKOUT TAGOUT STILL CRAZY AFTER ALL THESE YEARS?

Arc Flash Hazards in Metering

Arc Flash Hazards in Metering

Power City Electric Safety Management System. Job Name: Job #

NFPA 70E Standard for Electrical Safety in the Workplace. EEI Safety and Health Meeting April 2009

Plant Services Special Report. Assess the Threats; Train the Teams; Protect the People

Electrical Safe Work Practices Program

Optimize the Performance of New Electrical Equipment Installations

Schaedler Yesco Expo 2010

* All equipment grounding conductors shall be tested for continuity and shall be electrically continuous.

RISK CONTROL SOLUTIONS

PERSONAL PROTECTIVE EQUIPMENT

Standard for Electrical Safety in the. October 2009

Grounding Conductor & GFCI Employee Protection Program

Electrical Safety Programs

Top 2018 NFPA 70E Updates Worth Discussing

2 Program Requirement Document RECORD OF ISSUE/REVISION. Description of Changes

Electrical Safety. ESWP and NFPA 70E Electrical Safe Work Practice

OSHA PUBLISHED FIRST-EVER ARC FLASH PROTECTION REQUIREMENTS FOR THE ELECTRIC POWER INDUSTRY

Title: Lockout/Tagout Policy. University Division/Department: Environmental Health & Safety Effective Date : May, 1996 Revised: July, 2017

Building a Culture of Safety. RLI Design Professionals DPLE 185 November 1, 2017

Made by engineers for engineers

T08 - Maintaining Your Safety Plan

A Guide for Designing and Implementing Arc Flash Mitigation

TOOLS, EQUIPMENT, AND PERSONAL PROTECTIVE EQUIPMENT ASSOCIATED WITH THIS PROCEDURE

Session Ten: Arc Flash Protection Study Eskom Kendal Power Station

Enterprises. Current Course List July 2015 page 1 of Martin Ave. Salina, Ks

Individual Unit Function: Safety Procedure No.: SOP-0138 Page: 1 of 10

Revision Implementation

EEI Occupational Safety & Health Committee Spring Conference Louisville, KY April 27 30, 2008

Brian Moore. All Contractors. Regarding: Contractor Safety Introduction Letter and Packet. To Whom It May Concern:

Energy Control and Lockout Tagout

Ground Fault Circuit Interrupters (GFCI) & Assured Grounding Program

Advanced Electrical Safety Training

STANDARDIZING ARC FLASH PPE LABELS

ARC Frequently Asked Questions

IT S ALL ABOUT PROTECTING PEOPLE

SUBCONTRACTOR MANAGEMENT PLAN

Process Safety Management (PSM) Program. General Company Policy

Amendment A National Electric Code

Arc Flash Risk in Wind Energy Systems. Guidelines for analysis, mitigation and management

Safety Approach. September 2016

ESSENTIAL SAFETY RESOURCES

SECTION GENERAL ELECTRICAL REQUIREMENTS

Procedure. Procedure

Direct and Indirect Benefits

NZQA unit standard version 1 Page 1 of 5

SAMPLE PAGES. Construction Safety and Health Program. [Company name]

New Mexico Institute of Mining & Technology. Lockout/Tagout Policy

Personal Protective Equipment (PPE) Safety Program

Title: Lockout / Tagout Effective Date: 11/28/2014 Control Number: THG_0008 Revision Number: 1 Date: 10/8/2015 Annual Review Completed: 5/13/2015

Storm Response & Onboarding. Safety First and Always

CAL/OSHA ELECTRICAL HIGH VOLTAGE

TAMKO s Statement of Policy on Safety

INJURY AND ILLNESS PREVENTION PROGRAM. Adopted June 25, 1991 by Board Resolution 91-95

Hidden Risks of Aging Electrical Systems

Career Paths in Safety

Service plans enhance the benefits of preventive maintenance programs

Cranes & The Criminal Code of Canada

Effective Date: 10-January Table of Contents

4. Stationary scaffolds over 125 ft. in height and rolling towers over 60 ft. in height must be designed by a professional engineer.

A Practical Methodology to Arc Flash Mitigation Strategy

Section /Subpart Title Goes V Amendments Here

INJURY AND ILLNESS PREVENTION PROGRAM

Delaware State University

CUSP Base Exams and T&D Endorsement Exam Sample Questions and Format

Personal Protective Equipment (PPE) Program

Delaware State University

Critical Elements from the Arrium Codes of Practice (Including Arrium Mining Codes of Practice)

LOCKOUT / TAGOUT PROGRAM

Contractor EHS Program Attachments

JOB SAFETY ANALYSIS PROGRAM. Owner: Risk Management Revision No: 01. Document number: Q-001 Date last revised:

ECCS Information Form

LOCKOUT TAGOUT SAFETY PROGRAM

SWITCH GEAR SERVICE AND MAINTAINNANCE SAFETY MEASURES AND REQUIREMENTS

Tom Carpenter Crane Maintenance Technician

EHS Solutions Based in Reality

SAN FRANCISCO PUBLIC UTILITIES COMMISSION S WATER SYSTEM IMPROVEMENT PROGRAM (WSIP) SAFETY APPROACH

SUBCONTRACTOR MANAGEMENT PLAN

Laboratory Power Quality

Transcription:

OSHA s Enforcement and Significant Changes in 2015 NFPA 70E Presented by Doug Tellin Electrical Safety Specialists LLC.

Aristotle Educating the mind without educating the heart is no education at all.

1 out of 300 1 out of 10 Safety Overall 1 Fatality 30 Lost-Time Injuries 1 Fatality Electrical Safety 300 Recordable Injuries 30,000 Near Misses 10 Recordable Injuries 300,000 At-Risk Behaviors Electrical Safety should be a MAJOR concern! 3

Better to Plan and Prevent than to Repair and Repent 4

NFPA 70E 2015 And OSHA Have set the bar high! NPFA70, NFPA 70E, NFPA 70B, NFPA 99 are all trade marks of the National Fire Protection Association, INC 5

OSHA S mission is not SEEK AND DESTROY OSHA S mission is IDENTIFY AND FIX

OSHA S EXPECTATIONS Never work on live circuits unless it is absolutely necessary. OSHA has strict guidelines for working live circuits. Production or inconvenience is not justification for working energized. Not having the authority to shut off power, cannot be used as an excuse for workers.

OSHA S EXPECTATIONS 1. Was an arc flash hazard analysis performed? 2. Were flash protection boundaries established? 3. Were all other potential electrical hazards identified? 4. Was a shock hazard analyses performed? 5. Were shock hazard boundaries established? These are all Questions every EHS professional should have an answer to.

OSHA S EXPECTATIONS This can be a very complex task for most facilities. OSHA inspectors are trained to ask if these analyses were performed This is the only way for electrical hazards to be reduced to a manageable level.

OSHA S EXPECTATIONS Go Home the way you came to work today. Don t make your family the victim of complacency.

OSHA S EXPECTATIONS The employer must show proof of the appropriate training and certifications for a person to be deemed qualified in OSHA s Eyes This is achieved by training, even for the experienced electrician.

OSHA S INSPECTIONS Employer May Qualify for a "Focused Inspection" Inspector will "focus" on these four hazard areas: Falls Struck by Caught in/between Electrical

OSHA S INSPECTIONS Example OSHA Citation

NFPA 70E Standard for electrical safety in the workplace Arc Flash Assessments and reviews every 5 years! Only qualified persons working within the limited approach boundary energized parts! Retraining every 3 years! Annual audits of performance! CPR/AED annually! Release of victims training annually! 16

Electrical Arc Flash/Blast 35,000 F Molten Metal Pressure Waves Sound Waves Copper Vapor: Solid to Vapor Expands by 67,000 times Shrapnel Rapid Expansion of Hot Air Intense Light

130.5 Arc Flash Risk Assessment An arc flash risk assessment shall be performed and shall: (1) Determine if an arc flash hazard exists. If an arc flash hazard exists, the risk assessment shall determine: a. Appropriate safety-related work practices b. The arc flash boundary c. The PPE to be used within the arc flash boundary

Tables VS. Analysis 19

Tables VS. Analysis 20

Table 130.4(D)(a). 21

TIME CURRENT CURVE (TCC) CB 3 Square D QO 150 Amp 240 volt 1/0 awg 150 long 2.67KA 2.0 SEC 15.53 CAL/CM² HRC 3 CB 8 Square D QO 150 Amp 240 volt 1/0 awg 50 long 3.34KA.023 SEC.23 CAL/CM² HRC 0 CB 7 Square D QO 150 Amp 240 volt 1/0 awg 100 long 2.97KA.029 SEC.24 CAL/CM² HRC O

Arc Flash Boundary Incident Energy Analysis PPE Requirements Label Location Nominal Voltage Approach Boundaries Date

4 cal/cm²

ARC Rating of 8 cal/cm² Cotton

Hierarchy of Electrically Safe Workplace

110.1 (G) Risk Assessment Procedure (1) Identify hazards (2) Assess risks (3) Implement risk control according to a hierarchy of methods: (1) Elimination (2) Substitution (3) Engineering controls (4) Awareness (5) Administrative controls (6) PPE

110.1 Electrical Safety Program (B) Maintenance. The electrical safety program shall include elements that consider condition of maintenance of electrical equipment and systems.

What are we going to Cover Training Requirements Qualified Persons Retraining Requirements

Proper Use of Test Instruments Article 110.4(1) Testing Only qualified persons shall perform tasks such as testing, troubleshooting, and voltage measuring within the LAB or energized electrical conductors or circuit parts operating at 50 volts or more or where an electrical hazard exists.

There are many effective ways to train employees.

110.2 Training Requirements. (C) Emergency Response Training Employees shall be trained: (1) Contact Release. Employees exposed to shock hazards shall be trained in methods of safe release of victims from contact with exposed energized electrical conductors or circuit parts. Refresher training shall occur annually.

110.2 Training Requirements. (C) Emergency Response Training Employees shall be trained: (2) First Aid, Emergency Response, and Resuscitation. (a) Employees responsible for responding to medical emergencies shall be trained in first aid and emergency procedures. (Periodically) (b) Employees responsible for responding to medical emergencies shall be trained in cardiopulmonary resuscitation (CPR). Refresher training shall occur annually.

110.2 Training Requirements. (C) Emergency Response Training Employees shall be trained: (2) First Aid, Emergency Response, and Resuscitation. (Continued) (c) Employees responsible for responding to medical emergencies shall be trained in the use of an automated external defibrillator (AED) if an employer s emergency response plan includes the use of this device. Refresher training shall occur annually.

110.2 Training Requirements. (C) Emergency Response Training (3) Training Verification. Employers shall verify at least annually that employee training required by this section is current. (4) Documentation. The employer shall document that the training required by this section has occurred.

100 Definitions Qualified Person. One who has demonstrated skills and knowledge related to the construction and operation of electrical equipment and installations and has received safety training to identify and avoid the hazards involved.

OSHA Definitions Qualified Person. The latest revision of the OSHA definition for qualified person (1910.399 8/07) includes the phrase has demonstrated skills. To meet this requirement, the person has to actually demonstrate that he/she can perform the task.

Summary of Qualified Persons Skills Trained Taught Learned Demonstrated ability to Perform task safely

Summary of Qualified Persons Skills Is permitted to work Operating at 50 volts or more Within the limited approach boundary of Energized conductors and circuit parts (this is what system and equipment is made of)

110.2 Training Requirements. (D)(1) (e) Qualified Person. Employees shall be trained to select an appropriate test instrument and shall demonstrate how to use a device to verify the absence of voltage, including interpreting indications provided by the device. The training shall include information that enables the employee to understand all limitations of each test instrument that might be used.

110.2 Training Requirements. (D)(1) (f) Qualified Person. The employer shall determine through regular supervision or through inspections conducted on at least an annual basis that each employee is complying with the safety-related work practices required by this standard.

110.2 Training Requirements. (D)(3) Retraining Retraining in safety-related work practices and applicable changes in this standard shall be performed at intervals not to exceed three years.

110.2 Training Requirements. (E) Training Documentation The employer shall document that each employee has received the training required by 110.2(D). This documentation shall be made when the employee demonstrates proficiency in the work practices involved and shall be maintained for the duration of the employee s employment. The documentation shall contain the content of the training, each employee s name, and dates of training.

Questions? More Information? Doug Tellin dtellin@qualifiedtrainings.com Greg Windisch gwindisch@qualifiedtrainings.com Visit us on the web. Arcflashpro.com Call for a free consultation (816) 925-0443