Venturi Tubes in Wet Gas Improved Models for the Over- Reading and the Pressure-Loss Ratio Method

Similar documents
Flow measurement: some problems to solve and some surprises. Dr Michael Reader-Harris, NEL

Laboratory Testing of Safety Relief Valves

An Intercomparison between NEL, CMS/ITRI, SIPAI, KRISS, IPT and CENAM using a 200 mm Twin Orifice Plate Package in Water

VENTURI FLOW METER CALIBRATIONS SERIAL NUMBERS: , , , Prepared for. Imperial Flange and Fitting.

Effects of Pipe Wall Offsets on Differential Pressure Meter Accuracy

MEASUREMENT OF AIRFLOW

Pipe Flow Hydraulics

Clamp-on Two Phase Measurement of Gas Condensate Wells Using Integrated Equation of State Compositional Models

ISO INTERNATIONAL STANDARD

Permanent Pressure Loss Comparison Among Various Flowmeter Technologies

Tracer Dilution Measurements for Two-Phase Geothermal Production: Comparative Testing and Operating Experience

Universities of Leeds, Sheffield and York

Flow Conditioning Why, What, When and Where. Gas Flow Conditioning Why, What, When and Where

Dr. J. Wolters. FZJ-ZAT-379 January Forschungszentrum Jülich GmbH, FZJ

COIN. Flow Meters. Segmented Wedge. Your First Choice in Intelligent Flow Management...

An Intercomparison Between NEL, NRLM, Delft Hydraulics, Alden Research Laboratories, CENAM and NIST Using a 200 mm Twin Orifice Plate Package in Water

Effects of Geometrical Parameters on Performance Characteristics of Venturimeter

Journal of Mechanical Science and Technology 25 (8) (2011) 1961~ DOI /s

VENTURI FLOWMETERS. Your First Choice in Intelligent Flow Management...

Erosion Effects in Flowmeters

ASME PTC Flow Measurement

Numerical analysis of eccentric orifice plate using ANSYS Fluent software

ORIFICE MTERE BASIC SELECTION & DESIGN CONSIDERATIONS. All rights reserved to thepetrostreet.com

HYDRAULIC DEMONSTRATION CHANNEL

Problems with Pitots. Issues with flow measurement in stacks.

GUIDANCE NOTE. Performance of Electromagnetic Meters Designed for Use in Part-Filled Pipes.

Flow Meter Calibration

Best Practice Guide: Test protocol and approach to multiphase test facility intercomparisons utilising a MPFM transfer standard

The Paradigm Case Method of Flowmeter Selection

Custom Engineered Flow Meters. Differential Pressure Products

Gilflo flowmeters. for steam, liquids and gases

Design, Fabrication & CFD Analysis of Multi-Hole Orifice Plate

Utility Flow Metering for Steam and Heated/Chilled Water: A Tutorial. Richard Gruskos Flow Products Manager Kessler Ellis Products

Impact of Pitot tube calibration on the uncertainty of water flow rate measurement

FLUID MECHANICS PROF. DR. METİN GÜNER COMPILER

Master Meter Testing at Water Plants and Pump Stations. Jeff Cruickshank, PE

HIGH PERFORMANCE FLOW CONDITIONERS Michael P. Saunders Savant Measurement Corporation USA

CUSTODY TRANSFER FLOW MEASUREMENT WITH NEW TECHNOLOGIES. Stephen A. Ifft McCrometer Inc. Hemet, California, USA

A REVIEW OF STEAM FLOWMETERING TECHNOLOGY

Setting The Standard

I. CHEM. E. SYMPOSIUM SERIES NO. 85 THE SMALL-SCALE RELEASE RATE OF PRESSURISED LIQUEFIED PROPANE TO THE ATMOSPHERE

Gilflo ILVA flowmeters for steam, liquids and gases

February 5, 2013 Roy Ratcliffe, President RM Controls, Inc.

COOLING TECHNOLOGY INSTITUTE

Effect of Orifice Plate Shape on Performance Characteristics

Computational Fluid Dynamics (CFD) Simulations of Dispersed Flow of Viscous Oil in Water in a Horizontal Pipe

Level 6 Graduate Diploma in Engineering Hydraulics and hydrology

TVA Target Variable Area Flowmeter

Field Experiences with V Cone Technology. McCrometer Inc. Hemet, CA.

Final DRAFT API TECHNICAL REPORT. Carbon Content, Sampling, & Calculation

VERIS Accelabar. Superior Flow Measurement Accuracy

Naturally Entraining Solid Particle Injector

WHITE PAPER A New Approach to Accurate Water Flow Measurement - The Study of the FPI Mag Accuracy

COMPARATIVE STUDY ON ORIFICE VERSUS TURBINE METERS FOR GAS FLOW MEASUREMENT

Flow Test Data Book and Flow Handbook for 405 Compact Orifice Series and 1595 Conditioning Orifice Plate

Mexico Gas Flaring Reduction. EU Flaring Regulatory Measurement Requirements & Best Practice Lynn Hunter

WYATT Orifice flow PrOducTs

ISO 3966 INTERNATIONAL STANDARD. Measurement of fluid flow in closed conduits Velocity area method using Pitot static tubes

Carbon Dioxide as a Test Fluid for Calibration of Turbine Meters

Comparison of Four Gas Measurement Technologies Orifice/Turbine/Coriolis & Ultrasonic

VI.3 Application of Computational Fluid Dynamics to Simulate the Behaviour of Fluids inside Vertical Stack of Building Drainage System

Factors Affecting Air Entrainment of Hydraulic Jumps within Closed Conduits

Field Experiences with V -Cone Technology. Philip A. Lawrence McCrometer Inc O&G Office Houston TX.

Void Fraction of CO2 and Ammonia in Multiport Aluminum Microchannel Tubes

Analysis of Side Sluice in Trapezoidal Channel

Fluidised bed for stripping sand casting process. Guido Belforte, Massimiliana Carello, Vladimir Viktorov

Numerical and Experimental Modeling of Producer Gas Carburettor

Flow Measurement in Large Ducts & Pipes

Doc No.:FAD17 (2224)C Draft INDIAN STANDARD IRRIGATION EQUIPMENT RAIN GUN SPRINKLER Specification PART 2 TEST METHOD FOR UNIFORMITY OF DISTRIBUTION

flow measurement Methods

SCA : EXPERIMENTAL RESULTS FOR HIGH FLOW RATES OF OIL-WATER THROUGH HIGH PERMEABILITY MEDIA

Available online at ScienceDirect. Procedia Engineering 102 (2015 )

CFD SIMULATION AND EXPERIMENTAL VALIDATION OF FLUID FLOW IN LIQUID DISTRIBUTORS

Feedwater Flow Measurement with Venturi and Comparison to the other Parameters in NPP Krško

Lab #3 Conservation Equations and the Hydraulic Jump CEE 331 Fall 2004

RUNYI GROUP. Main Features. STLU Vortex Flow Meter

Research Article Flow Measurement Model of Ultrasonic Flowmeter for Gas-Liquid Two-Phase Stratified and Annular Flows

Determining Optimal Discharge and Optimal Penstock Diameter in Water Turbines

HORIZONTAL SHELL SIDE FLUIDIZED BED HEAT EXCHANGER, DESIGN CONSIDERATIONS AND EXPERIENCES FROM A PILOT UNIT

FLUID MECHANICS CIVIL ENGINEERING VIRTUAL LABORATORY

LECTURE 13. Fundamentals of Converter Steelmaking Technology. Key words: BOF steelmaking, jet penetration, refining reaction, soft and hard jet

x. ZHOU AND W. P. JEPSON

heat exchanger modelling for generator ventilation systems

ON-SITE PROVING OF GAS TURBINE METERS Edgar B. Bowles, Jr., Southwest Research Institute

Performance of an Air-Assist Nozzle Using Heated Air

Transient and Succession-of-Steady-States Pipeline Flow Models

Orifice Plates. All types of Orifice Plates and. relative products

SAM IL INDUSTRY CO.,LTD. IN THIS CHAPTER - 5

An Experimental Investigation into the Pressure Leakage Relationship of some failed water pipes

FLOMEKO 2004 Gulin Sept. 2004

This document is a preview generated by EVS

Comparative Analysis of Different Orifice Geometries for Pressure Drop

EMRP 2009 Metrology for Liquefied Natural Gas (LNG) ENG03 LNG. (WP1-Tasks and Final report)

The Integral Optimization Method of Oilfield Production System

Flow Characterization of a Piezo-Electric High Speed Valve

Experimental Investigations of Two-Phase Liquid-Liquid Horizontal Flows Through Orifice Plates

API Review. Copyright 2007, FMC Technologies Measurement Solutions, Inc. PR0A028I Issue/Rev. 0.0 (7/07) - Slide 1

MEASURMENT OF THE FILM THICKNESS, FILM VELOCITY AND ENTRAINMENT FRACTION IN A LIQUID-AIR ANNULAR FLOW USING A CONDUCTANCE FLOWMETER

Measurement of Two Phase Flows in Geothermal Pipelines Using Load-Cells: Field Trial Results

Comparison MPFM performances at NEL Multiphase facility

Transcription:

Venturi Tubes in Wet Gas Improved Models for the Over- Reading and the Pressure-Loss Ratio Method Michael Reader-Harris, TUV NEL Emmelyn Graham, TUV NEL 1 INTRODUCTION Venturi tubes are one of the most widely used meters for wet-gas flows. Reasons for this include their physical robustness to withstand erosion and the impact of liquid slugs at high velocities, familiarity with their use and the availability of standards for their use in dry-gas conditions. The presence of the liquid causes an increase in the measured differential pressure and results in the Venturi tube over-reading the actual amount of gas passing through the meter. This over-reading is usually corrected using available correlations derived from experimental data to determine the actual gas mass flowrate. This trend is observed in all differentialpressure meters. The flowrate of the liquid, which can be a combination of water and hydrocarbons, is normally determined by an external means such as from test separator data, tracer experiments or sampling etc. Information on the liquid flowrate and density is necessary to use the correlations. The correlations currently available for correcting the over-reading of Venturi tubes have been derived from a limited set of data and may only be suitable to cover restricted ranges of Venturi tube parameters, for example, a specific diameter ratio. Use of correlations outside the conditions used to define them can result in large errors in the calculation of the gas mass flowrate. This paper describes a new Chisholm/de Leeuw-type model for the over-reading, which covers a broader range of Venturi parameters such as diameter ratio and pipe diameter. The model also accounts for the behaviour of the over-reading with different liquids. 2 DEFINITIONS OF WET-GAS FLOW For the research presented in this paper wet-gas flow is defined as the flow of gas and liquids with a Lockhart-Martinelli parameter, X, in the range 0 < X 0.3. The Lockhart-Martinelli parameter, X m ρ liq gas = (1) mgas ρliq where m liq and m gas are the mass flowrates of the liquid and gas phase respectively and ρ liq and ρ gas are the densities of the liquid and gas phase respectively. In this work the density of the gas phase is that at the upstream pressure tapping, ρ 1,gas. The gas densiometric Froude number, Fr gas, is a dimensionless number directly proportional to the gas velocity. It is defined as the square root of the ratio of the gas inertia if it flowed alone to the gravitational force on the liquid phase. Gas densiometric Froude number, Fr gas = v gas gd ρ liq ρ 1,gas ρ 1,gas (2) 1

where v gas is the superficial gas velocity, g is the acceleration due to gravity and D is the pipe internal diameter. The superficial gas velocity is given by where A is the pipe area. v gas m gas = (3) ρ1,gas A The gas-to-liquid density ratio, DR, is defined as 1,gas DR = ρ (4) ρ liq The corrected gas mass flowrate, m gas, is given by m gas EAd Cεwet 2ρ1,gas pwet mgas,apparent = = (5) φ φ where E is the velocity of approach factor defined below, A d is the Venturi-tube throat area, C is the discharge coefficient in the actual (wet-gas) conditions, ε wet is the gas expansibility in wet-gas conditions, p wet is the actual (wet-gas) differential pressure, φ is the wet-gas overreading or correction and m gas,apparent is the apparent or uncorrected gas mass flowrate. ε wet was determined from ISO 5167-4 [1] using the actual value of pressure ratio. The velocity of approach factor, E, is defined as E = 1 1 β 4 (6) φ p wet-gas p gas (7) 3 BRIEF HISTORY OF WET-GAS CORRELATIONS Correlations for the use of orifice plates in wet-gas conditions have existed since the 1960s; the most commonly used correlations are those of Murdock and Chisholm. These correlations are still used and commonly referred to. These equations have been applied to other types of differential-pressure meter including Venturi tubes. Research by Murdock [2] in 1962 on orifice plates in wet-gas conditions stated that the wetgas over-reading was dependent on the Lockhart-Martinelli parameter. Murdock s correlation gave the over-reading as φ = 1+ 1.26 X (8) 2

Chisholm s research on orifice plates found that the wet-gas over-reading was dependent on the Lockhart-Martinelli parameter and the gas-to-liquid density ratio [3, 4]. Many of the available correlations for correcting the wet gas over-reading are based on the Chisholm model. Chisholm s correlation gave the over-reading as 2 φ = 1+ CCh X + X (9) where C Ch accounts for the density ratio and is given by the following equation: CCh n n ρliq ρ1,gas = + ρ 1,gas ρ liq (10) where n = 0.25. The most commonly used correlation for Venturi tubes is that of de Leeuw published in 1997 [5]. He used data collected from a 4-inch, 0.4 diameter-ratio Venturi tube and fitted the data using a modification of the Chisholm model. This research found that the wet-gas overreading was dependent on the Lockhart-Martinelli parameter, the gas-to-liquid density ratio and the gas Froude number. De Leeuw used Equations (9) and (10) but showed that n was a function of the gas Froude number: n = 0.41 for 0.5 Frgas < 1.5 (11) 0.746Frgas ( e ) n = 0.606 1 for Frgas 1.5 (12) The de Leeuw correlation or modifications of the Murdock and Chisholm correlations are used extensively throughout industry to correct for the differential-pressure over-reading from Venturi tubes and to determine the actual gas flowrate. However, it is known that the extrapolation of an empirical correlation derived from a set of data with a limited range of a particular parameter has risks and that this can increase the measurement errors. This risk can be accounted for by increasing the uncertainty of the measurements derived from the correlation. It is worth noting that increased errors are more likely if using correlations at pressures lower than that covered by the correlation, rather than at higher pressures. This is due to the fact that at lower pressure the density ratio (of the gas to the liquid) is lower, and hence the fluid combination is less homogeneous. Since the publication of de Leeuw s correlation it has been shown by Stewart et al. [6] that there is a diameter-ratio effect on the wet-gas over-reading. Reader-Harris et al. [7, 8] and Steven et al. [9, 10] have shown that the liquid properties can have an effect on the response of differential-pressure meters in wet-gas conditions. Other correlations have been published and an in-depth review is provided by ASME [11]. There are no openly available correlations based on data that cover the range of fluid conditions and parameters that are encountered by industry. 3

4 DERIVATION OF NEW CORRELATION Most of the available correlations are based on Chisholm s model, which produces an almost straight-line fit though the wet-gas data. This type of model generally provides an acceptable fit for orifice-plate data. However, with Venturi data it is noticeable that as the Lockhart- Martinelli parameter, X, tends towards zero the over-reading does not tend to zero in a linear fashion. The gradient changes as the liquid fraction and hence the Lockhart-Martinelli parameter, X, tend to zero. This is in contrast to data from orifice plates (although sometimes with orifice plates the straight line fails to go exactly through the origin). Figure 1 clearly illustrates the problem for a 0.6 diameter-ratio Venturi tube using different fluid combinations with either nitrogen or argon as the gas phase and water or Exxsol D80 (a kerosene-substitute fluid) as the liquid phase. 1.6 1.5 Venturi Meter Overreading, φ 1.4 1.3 1.2 1.1 1 Nitrogen-Exxsol D80 Argon-Exxsol D80 Nitrogen-Water Equation (13) 0 0.025 0.05 0.075 0.1 0.125 0.15 0.175 0.2 0.225 0.25 0.275 0.3 0.325 Lockhart-Martinelli Parameter, X Figure 1 Over-reading data for a 4-inch Venturi tube with β = 0.6, Fr gas = 1.5, ρ 1,gas /ρ liquid = 0.024 One solution to account for this effect would be to add an additional term to the model to provide a better fit to the data (e.g. as in [7]), but this has no obvious physical significance. For the data presented in Figure 1 (excluding data with X < 0.02) if a multiplicative term is acceptable the best fit of a Chisholm-type model is: φ = 1.0532 1+ C X + X, where Ch 2 0.3162 0.3162 ρliq ρ1,gas CCh = + ρ 1,gas ρ liq (13) The over-reading is corrected and provides a better fit to the data (with X > 0.02) by modifying the power index in the Chisholm constant (C ch ) to a value between those used by Chisholm and de Leeuw, and by adding a multiplicative constant to the over-reading equation. It is proposed here that the reason for the non-linearity is that in wet-gas conditions the discharge coefficient, C, is not equal to its dry-gas value, as is often assumed. As soon as even a very small quantity of liquid is added to the gas the discharge coefficient reduces. It is interesting to note that, whereas in dry gas a Venturi tube can often emit an audible tone (it is sometimes referred to as a singing Venturi), in wet-gas conditions Venturi tubes never sing ; even a tiny quantity of liquid seems to change the flow in such a way as to prevent the emission of an audible tone. 4

For the Venturi tube whose data are in Figure 1 the dry-gas discharge coefficient is a function of Reynolds number with a mean value of 1.009 over all its calibrations. However, the effective discharge coefficient in wet gas when calculated for X > 0.02 is more than 5% lower than the value in dry gas. The effective discharge coefficient was calculated by determining best-fit values of C and n in Equations (5), (9) and (10) for the data with X > 0.02. Following this observation the discharge-coefficient values in wet-gas conditions were calculated for more data sets to establish if the discharge coefficients in dry and wet gas were generally different. The discharge coefficients were calculated from Equations (5), (9) and (10) (allowing n to vary) for the data sets in Table 1. Table 1 Wet Gas Data Beta ratio Pipe size Gas phase Liquid phase Reference 0.4 4-inch nitrogen Exxsol D80 6 0.6 4-inch nitrogen water 7, 8 0.6 4-inch nitrogen Exxsol D80 7, 8 0.6 4-inch argon Exxsol D80 7, 8 0.75 4-inch nitrogen water 7, 8 0.75 4-inch nitrogen Exxsol D80 7, 8 0.75 4-inch argon Exxsol D80 7, 8 0.55 6-inch nitrogen Exxsol D80 12 The discharge coefficient in dry-gas conditions varies between the different Venturi tubes. So it is not surprising that there is a significant variation in the value of the discharge coefficient in wet-gas conditions. This variation makes it harder to see what parameters affect the value. Flow calibrations usually relate the discharge coefficient to the Reynolds number; however, from analysis of the data it seemed more reasonable to use the throat Reynolds number or throat Froude number. Of these the throat Froude number seems more reasonable to use on physical grounds. The throat Froude number is calculated as: Fr Fr gas gas,th = (14) 2.5 β Figure 2 shows the discharge-coefficient data plotted as a function of the throat Froude number. 5

1.0100 1.0000 0.9900 0.9800 C 0.9700 beta = 0.4 nitrogen/exxsol D80 6-inch beta = 0.55 nitrogen/exxsol D80 0.9600 beta = 0.6 nitrogen/exxsol D80 beta = 0.6 argon/exxsol D80 0.9500 beta = 0.6 nitrogen/water beta = 0.75 nitrogen/exxsol D80 0.9400 beta = 0.75 argon/exxsol D80 beta = 0.75 nitrogen/water 0.9300 0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 Fr gas,th Figure 2 Values of the discharge coefficient as a function of Fr gas, th. Data from Table 1 The power index, n, from the Chisholm correlation (in Equation (10)) has been calculated and plotted in Figure 3 against a suitable function of Fr gas. The function exp(-0.8fr gas /H) was used to linearise the data. The choice of the liquid has a significant effect and this has been accounted for in the use of an additional term, H. H depends on the liquid type and was defined as equal to 1 for Exxsol D80. H = 1 is found to be a satisfactory value for other hydrocarbon liquids, and H = 1.35 was determined for water from fitting the data. Analysis of the available data shows that the choice of gas has a negligible effect on the relationship between n and Fr gas, provided that the density ratio between the gas and the liquid is kept constant. 6

n 0.60 0.55 0.50 0.45 0.40 beta = 0.4 nitrogen/exxsol D80 6-inch beta = 0.55 nitrogen/exxsol D80 beta = 0.6 nitrogen/exxsol D80 beta = 0.6 argon/exxsol D80 beta = 0.6 nitrogen/water beta = 0.75 nitrogen/exxsol D80 beta = 0.75 argon/exxsol D80 beta = 0.75 nitrogen/water 0.35 0.30 0.25 0.20 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 exp(-0.8fr gas /H ) (H = 1 Exxsol D80; H = 1.35 water) Figure 3 Values of the power index, n, from the Chisholm constant, as a function of the gas Froude number. The strong effect of the liquid could suggest that the phase boundaries for a wet-gas flow in which the liquid is water are actually different from those in which the liquid is Exxsol D80 (or a general hydrocarbon liquid). Figure 4 shows the two-phase flow pattern map produced by Shell, which is commonly referred to in many wet-gas documents. This shows the flow conditions where certain flow patterns, for example stratified flow, are likely to exist. The phase boundaries, illustrated in this figure, between the flow regimes may depend on the liquid properties. This work and previous CFD [7] suggest that the effect of the liquid on the overreading of Venturi tubes is strongly related to the surface tension of the liquid. 10 X=1 Densiometric Liquid Froude No. (Fr l ) 1 0.1 0.01 0.001 Slug Stratified Annular Dispersed X=0.1 X=0.01 0.0001 0.001 0.01 0.1 1 10 Densiometric Gas Froude No. (Fr g ) Figure 4 Horizontal two-phase flow pattern map (courtesy of Shell) 7

The analysis presented so far established appropriate dependencies for the values of n and C to develop a new correlation based on the Chisholm correlation. The range of data used for development of the correlation was extended and is summarised in Table 2. Table 2 Wet gas data Diameter ratio Pipe size Gas phase Liquid phase Reference 0.6 2-inch natural gas Stoddard solvent 9 0.6 2-inch natural gas water 9 0.4 4-inch nitrogen Exxsol D80 6 0.4 4-inch natural gas decane 13 0.6 4-inch nitrogen water 7, 8 0.6 4-inch nitrogen Exxsol D80 7, 8 0.6 4-inch argon Exxsol D80 7, 8 0.6 4-inch nitrogen Exxsol D80-0.6 4-inch natural gas Exxsol D80 -* 0.7 4-inch steam very hot water 14 0.75 4-inch nitrogen water 7, 8 0.75 4-inch nitrogen Exxsol D80 7, 8 0.75 4-inch argon Exxsol D80 7, 8 0.55 6-inch nitrogen Exxsol D80 12 * data points with the r.m.s of the fluctuating component of the differential pressure greater than 0.98% of the mean differential pressure were excluded. The values for n determined from the data from Table 2 were plotted in a similar manner to those shown in Figure 3 and fitted to determine a formula for n. The value of n was determined as the maximum value from one of two equations. These equations describe the two patterns in the data that can be seen in Figure 3 with the initial negative gradient changing to a horizontal line. n is the larger of the values returned by 2 0.8 Frgas / H n = 0.583 0.18 0.578e (15) and β 2 n = 0.392 0.18. (16) β This is summarised in one equation as 2 0.8 Frgas / H 2 n = max(0.583 0.18 0.578 e, 0.392 0.18 ) (17) β As can be seen from Figure 1 the over-reading value changes its slope as X tends to zero. This is due to a change in discharge coefficient. Therefore an appropriate equation was fitted to the data from Table 2 to account for this change in the discharge coefficient, C. The discharge coefficient was fitted based on a threshold value of X, called X lim. X lim was defined as the value where the over-reading data showed a distinct change in gradient. Then C is given by β 8

Cfully wet X Xlim C = X Cdry ( Cdry Cfully wet ) X < Xlim Xlim (18) where, from the overall fit of the data, X lim = 0.016 An effective discharge coefficient for wet gas, C fully wet, was determined by fitting the data from Table 2. This was based on an exponential fit as a function of throat Froude number, Fr gas, th 0.05Frgas,th e Cfully wet = 1 0.0463 (19) where the value of 1 is a remarkably close approximation to the fitted value for the singlephase discharge coefficient, C dry, which should apply both to dry-gas flow and to homogeneous flow as Fr gas,th tends to. A summary equation to determine the discharge coefficient, C, accounting for the full range of X is C -0.05Frgas,th = 1-0.0463e min 1, X 0.016 (20) Figure 5 shows the errors in the gas mass flowrate determined when using these new equations as a function of the Froude number. The data from Table 2 are used. The percentage errors were calculated as σ 100 m correlation = m actual (21) mactual where σ is the percentage error in the gas mass flowrate, m correlation is the gas mass flowrate determined from using the correlation and m actual is the actual measured gas mass flowrate. 9

4 3 % Error in gas mass flowrate 2 1 0-1 -2-3 -4 0 1 2 3 4 5 6 7 8 Fr gas Figure 5 Errors in gas mass flowrate using Equations (17) and (20) as a function of Fr gas As stated earlier the liquid type affects the over-reading value. Using the data for water, hydrocarbons and very hot water (in a steam/water flow) in Table 2 the value of H was determined. This value is shown in relation to the liquid properties of surface tension and viscosity in Table 3. This shows that there is no obvious correlation of H with the liquid viscosity and that it is more likely that the surface tension is the dominant factor in the value of H. Table 3 Liquid properties Liquid H (-) Surface tension (N/m) Viscosity (mpa s) Water 1.35 0.060 1 Hydrocarbon 1 0.027 2.4 Very hot water 0.79 0.022 0.1 5 TESTING THE CORRELATION The correlation was mostly fitted to data recorded for research purposes in which accurate dimensions were measured to check compliance with ISO 5167-4. However it is important to test the correlation using data that were not used to derive the correlation. This illustrates the applicability of the correlation to other Venturi tubes and can provide confidence in the use of the correlation. Krohne very kindly agreed to allow their data on a large number of Venturi tubes calibrated at TUV NEL in nitrogen/exxsol D80 to be used. The data for 0.4 β 0.75, where β is the diameter ratio, are summarised in Table 4. 10

Table 4 Wet gas data from Krohne Diameter ratio Pipe size Gas phase Liquid phase Number of Venturi tubes 0.6 4-inch nitrogen Exxsol D80 6 off 0.47 4-inch nitrogen Exxsol D80 1 off 0.43 4-inch nitrogen Exxsol D80 1 off 0.4 4-inch nitrogen Exxsol D80 1 off 0.57 6-inch nitrogen Exxsol D80 6 off 0.61 6-inch nitrogen Exxsol D80 5 off 0.61 10-inch nitrogen Exxsol D80 2 off The data for one of the 4-inch and for one of the 6-inch Venturi tubes were not used as each had a mean discharge coefficient in dry gas below 0.97. On the basis of Table B.2 of ISO 5167-4 it is expected that the discharge coefficient will be equal to 1.010 ± 3% for 10 8 > Re d > 2 10 6, where Re d is the throat Reynolds number. Overall the data from 20 Venturi tubes were used to test the correlation. Figure 6 shows the percentage error in the gas mass flowrate of the data used to derive the correlation (Table 2) and of the validation data from Krohne (Table 4) as a function of the gas Froude number. 4 3 Derivation data (Table 2) Validation data (Table 4) % Error in gas mass flowrate 2 1 0-1 -2-3 -4 0 1 2 3 4 5 6 7 8 Fr gas Figure 6 Errors in gas mass flowrate using Equations (17) and (20) as a function of Fr gas It can be seen that the Krohne validation data show only very slightly increased errors in the gas mass flowrate compared with the derivation data. This provides confidence that the correlation is robust enough to be used for Venturi tubes that are within the tolerances of the standard ISO 5167. The standard deviation of the errors in gas mass flowrate is given in Table 5. 11

Table 5 Standard deviation of errors in gas mass flowrate Data fitted to give best-fit Data tested to give errors equations Table 2 a Table 2 0.86% Table 2 a Tables 2 and 4 0.980% Tables 2 and 4 b Tables 2 and 4 0.969% Standard deviation of errors in gas mass flowrate Table 2 a Table 4 1.34% a Equations (17) and (20) b Equations (17) and (20) with revised constants On the basis of Table 5 there is no benefit in using the Krohne data as derivation data as the standard deviation of the errors only reduces from 0.980% to 0.969%. Moreover, it is better to use the Krohne data only for validation purposes since no metrological information on the Venturi tubes was available and since it was good to have test data to which the constants in Equations (17) and (20) had not been fitted. The error in the gas mass flowrate as a function of the Lockhart-Martinelli parameter, X, is presented in Figure 7 as this may be more informative. It is interesting to note that when the errors for the Venturi tube with mean C dry = 0.9694 (omitted because it was less than 0.97) are added to Figure 7 they are approximately 3% for small X but are less for larger X. This supports the view that Equations (17) and (20) can be used to determine the gas mass flowrate with an uncertainty of 3% for X 0.15 and 2.5% for 0.15 < X 0.3. 4 3 All derivation and validation data Cdry = 0.9694 % Error in gas mass flowrate 2 1 0-1 -2-3 -4 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 X Figure 7 Errors in gas mass flowrate using Equations (17) and (20) as a function of X In summary the new correlation can be used to determine the discharge coefficient in wet-gas conditions and a value for n to use in determining the wet-gas over-reading based on the Chisholm model. This can be used to determine the gas mass flowrate. From this research the over-reading was found to be dependent on the Lockhart-Martinelli parameter, the gas-toliquid density ratio, the gas densiometric Froude number, the diameter ratio and the liquid properties. 12

This new correlation can be used to determine the gas mass flowrate for the following Venturi tube parameters and wet-gas conditions: 0.4 β 0.75 0 < X 0.3 3 < Fr gas,th 0.02 < ρ 1,gas /ρ liq D 50 mm with an uncertainty of 3% for X 0.15 2.5% for 0.15 < X 0.3 It has been assumed here that there is no need for a maximum limit on Fr gas,th as at higher values of Fr gas,th the flow becomes more homogeneous and less likely to deviate from the behaviour accounted for in the correlation. 6 TESTING THE CORRELATION USING DATA WITH A MIXED LIQUID COMPOSITION OF HYDROCARBON AND WATER Most data available for research purposes have only a single liquid phase of hydrocarbon or water. However, in reality natural gas flows are usually a mixture of natural gas, liquid hydrocarbon and water. It is recognised that any correlation for a Venturi tube should ideally have been tested to cover the range of conditions it is likely to encounter in the field. Unfortunately this is not always possible owing to the limited amount of data that is available to derive and test correlations and the limitations of some test facilities to generate data. This new correlation has been tested with a limited data set using a liquid mixture of hydrocarbon and water. Because of the small quantity of available data it is not claimed that Equations (17) and (20) can be used for mixtures of liquid with the uncertainty quoted in section 5. Details of the data are provided in Table 6. Table 6 Wet gas data using a mixed liquid phase of liquid hydrocarbon and water Diameter ratio Pipe size Gas phase Liquid phase Reference 0.6 2-inch Natural gas Stoddard solvent and water 9 The water cut of the liquid phase varied from 21% to 76%. The value of H used for calculations was based on a linear scale between H = 1 for pure liquid hydrocarbon and H = 1.35 for pure water. Figure 8 shows the percentage errors in the gas mass flowrate of wet-gas data with a liquid mixture of hydrocarbon and water. It is noticeable that there appears to be a positive error bias when using the correlation but without the availability of a more extensive range of data it seemed unwise to fit an additional function to the data to determine a non-linear value for H. The errors from using the new correlation to determine the gas mass flowrate for this data with a mixed liquid phase are all within 3%. The Lockhart-Martinelli parameter, X, is in the range 0.02 to 0.11. 13

4 % Error in gas mass flowrate 3 2 1 0-1 -2-3 Frgas gas = 2.2 Frgas gas = 4.3-4 0 0.2 0.4 0.6 0.8 1 Water cut (fraction) Figure 8 Errors in gas mass flowrate using wet gas data with a liquid mixture of Stoddard solvent and water using Equations (17) and (20), as a function of the water cut. 7 TESTING THE DE LEEUW CORRELATION WITH THE NEW DATA SETS Figure 9 shows the percentage errors in the gas mass flowrate from using the de Leeuw correlation to determine the wet-gas over-reading for Venturi tubes. The percentage errors in the gas mass flowrate can be as large as 12% at high values of β. De Leeuw s correlation provides a good fit to the data with β = 0.4 with all the errors in the gas mass flowrate within 3%. This is not surprising as the correlation was derived from data obtained from a β = 0.4 Venturi tube. Since the derivation of the de Leeuw correlation research has shown that the wet-gas over-reading is dependent on the β. The errors in the gas mass flowrate increase as β increases from β = 0.4. 14

6 4 % Error in gas mass flowrate 2 0-2 -4-6 -8-10 -12-14 Beta = 0.4 Beta = 0.43-0.47 Beta = 0.55-0.61 Beta = 0.7-0.75 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 X Figure 9 Errors obtained using the de Leeuw correlation to fit the derivation data (Table 2) and validation data (Table 4) 8 USING PRESSURE-LOSS MEASUREMENTS TO DETERMINE THE LIQUID CONTENT The pressure loss across a Venturi tube is a function of the wetness of the gas. In dry gas the pressure loss is generally in the range of 5 to 30% of the differential pressure for a divergent angle of 15 o and in the range of 5 to 15% for a divergent angle of 7. In wet-gas conditions the pressure loss can be much greater and this can be exploited to determine the wetness. Under certain circumstances the ratio of the pressure loss to the differential pressure can be used to determine X and hence determine the gas mass flowrate without a separate measure of the liquid flowrate. All the information presented in this paper is based on Venturi tubes with a divergent angle of 7.5. The downstream tapping is placed 5D to 9D downstream of the downstream end of the divergent of the Venturi tube. ϖ p 6D-9D Flow 3.75 o Figure 10 Schematic of Venturi tube illustrating total pressure loss ( ϖ) and the differential pressure ( p) to calculate the pressure loss ratio ( ϖ/ p). (Note diagram is not drawn to correct scale or dimensions) 15

Table 7 shows the sets of data that were used to derive a correlation between the pressure loss ratio and X. Table 7 Wet gas data Diameter ratio Pipe size Gas phase Liquid phase 0.4 4-inch nitrogen Exxsol D80 0.6 4-inch nitrogen water 0.6 4-inch nitrogen Exxsol D80 0.6 4-inch argon Exxsol D80 0.75 4-inch nitrogen water 0.75 4-inch nitrogen Exxsol D80 0.75 4-inch argon Exxsol D80 0.6 4-inch nitrogen Exxsol D80 0.6 4-inch natural gas Exxsol D80 From these data the ratio of the pressure loss, ϖ, to the differential pressure, p, was determined in dry gas as ϖ p dry 9 = 0.0896 + 0.48β (22) The increase in pressure loss due to wetness was defined as Y ϖ ϖ = p p dry (23) The maximum value of the increase in pressure loss due to wetness cannot be exactly determined from the database, but a good approximation is obtained by defining Y max, as Ymax ϖ ϖ = p p dry X 0.3 (24) Y max was first plotted as a function of ρ 1,gas /ρ liq. This is shown in Figure 10. 16

0.6 0.5 0.4 Nitrogen/Exxsol D80 Argon/Exxsol D80 Nitrogen/water Y max 0.3 0.2 0.1 0 0 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.1 ρ 1,gas /ρ liq Figure 11 Y max as a function of ρ 1,gas /ρ liq for nominal values of Fr gas in the range 1.5 to 4.5 Figure 11 shows that that Y max is dependent on the density ratio as well as on the liquid type but appears to show no effect of the gas type. The argon/exxsol D80 and nitrogen/exxsol D80 fluid combinations have overlapping data points, whereas when the liquid is water (as in the Nitrogen/water combination) Y max has a higher value. From examination of the data it appears that the same dependence on liquid as was found when determining the value of n (Equation (17)), is appropriate to use here. Therefore the data for Y max were plotted against a function of Fr gas /H in order to account for the liquid type (Figure 12). 0.6 0.5 0.4 Density ratio 0.024 Density ratio 0.046 Density ratio 0.090 Y max 0.3 0.2 0.1 0 0.7 0.75 0.8 0.85 0.9 0.95 1 exp(-0.045fr gas /H ) Figure 12 Y max as a function of Fr gas /H 17

Figure 12 clearly shows a dependence on the density ratio, ρ 1,gas /ρ liq, and this dependence can be represented by a simple function that becomes extremely small as ρ 1,gas /ρ liquid tends to 1. The following form for Y max was then assumed: ρ1,gas Ymax = a exp b cfrgas / H ρ liq (25) On fitting the available data from Table 7 Y max was determined as ρ1,gas Ymax = 0.61exp 11 0.045 Frgas / H ρ liquid (26) Y/Y max was then evaluated for each point and plotted in Figure 13. 1.2 1 0.8 Y /Y max 0.6 0.4 0.2 0 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 X Figure 13 Y/Y max as a function of X In Figure 13 the levelling off (tending to a zero gradient) of the graph at higher values of X confirms that Y reaches its maximum value around X = 0.3. Even if X = 0.3 did not give the true maximum of Y this would not invalidate the final formula as it is based on Equation (24), not the true maximum. However, Figure 13 is inadequate for practical use. For example, a value of Y/Y max = 0.6 could give a value of X anywhere between 0.015 and 0.07. Therefore the data were replotted for small Y/Y max divided by ranges of Fr gas /H (Figure 14). Data obtained with Fr gas,th < 4 increased the uncertainty and were excluded. 18

0.7 Y/Y max 0.6 0.5 0.4 0.3 0.2 0.1 0 Fr gas /H 0.5 1-1.1 1.4-1.5 1.8-2.2 2.3-2.6 2.8-3.1 3.3-3.6 4.2-4.6 5.6 7.1 1.5: Equation (28) 3.5: Equation (28) 5.5: Equation (28) 0 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.1 X Figure 14 Y/Y max as a function of X, for Y/Y max < 0.7 and Fr gas,th > 4 The data in Figure 14 are fitted using the following form: Y Ymax d cfrgas ( / H bx e ) = 1 exp (27) This gives the following equation: Y Ymax 0.75 gas ( 0.28 Fr / H X e ) = 1 exp 35 (28) Provided a value of the pressure loss is known from measurements it is then possible to use Equations (22), (23) and (26) to determine values for Y and Y max. A value of X can then be determined from Equation (28), which can be used to determine the wet-gas over-reading using Equations (17), (9) and (10). The gas mass flowrate can be determined from Equation (5) using the over-reading and the value for the wet-gas discharge coefficient, C, determined from Equation (20). The percentage error in the gas mass flowrate as a function of Y/Y max is shown in Figure 15. The results are remarkably good, but as soon as Y/Y max exceeds 0.7 the method becomes very inaccurate. 19

5 4 % error in gas mass flowrate 3 2 1 0-1 -2-3 -4-5 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 Y/Y max Figure 15 Errors in gas mass flowrate for Fr gas,th > 4 using pressure loss and Equations (22), (26), (28), (17) and (20) To use these equations with Venturi tubes other than those from which the equation was derived it is desirable to be cautious as the equation has not been validated against additional data, as was done for the equations for n and C. A reasonable estimate for the uncertainty in gas mass flowrate using pressure loss ratio measurements and Equations (22), (26), (28), (17) and (20) is Y 4% for 0.6 Ymax Y 5% for 0.6 < < 0.7 Ymax Additional limits to those for the use of Equations (17) and (20) are that the divergent angle shall be between 7 and 8 Y Ymax < 0.7 Fr gas /H 5.5 ρ 1,gas /ρ liq 0.09 and Fr gas,th > 4. 20

9 CONCLUSION 9 th South East Asia Hydrocarbon Flow Measurement Workshop The new correlation can be used to determine a value for n in the wet-gas over-reading based on the Chisholm model. In addition, the discharge coefficient in wet-gas conditions, which has been found to differ from the value in dry-gas conditions, can be used with the over-reading to determine the gas mass flowrate in wet-gas conditions. This research found that the overreading was dependent on the Lockhart-Martinelli parameter, the gas-to-liquid density ratio, the gas densiometric Froude number, the diameter ratio and the liquid properties. The correlation can be used to determine the gas mass flowrate for the following Venturi tube parameters and wet-gas conditions: 0.4 β 0.75 0 < X 0.3 3 < Fr gas,th 0.02 < ρ 1,gas /ρ liq D 50 mm with an uncertainty of 3% for X 0.15 2.5% for 0.15 < X 0.3 The ratio of pressure loss to the differential pressure can be used to determine the liquid content in the wet-gas stream using the equations derived in this paper. Under certain circumstances this can eliminate the need for a separate technique to determine the liquid content. The uncertainty in gas mass flowrate using the additional equations to determine the liquid content is Y 4% for 0.6 Ymax Y 5% for 0.6 < < 0.7 Ymax where Y is the increase in the pressure loss ratio due to wetness and Y max is the maximum value of Y. 10 ACKNOWLEDGMENTS The work described in this paper was carried out as part of the National Measurement System s Engineering and Flow Programme, under the sponsorship of the United Kingdom Department for Business Innovation and Skills (formerly Department for Innovation, Universities and Skills). Krohne kindly agreed to allow their data to be used. Their help is gratefully acknowledged. We would like to thank CEESI for the release of their data which were used in this paper. This paper is published by permission of the Managing Director, TUV NEL. 21

11 REFERENCES 9 th South East Asia Hydrocarbon Flow Measurement Workshop [1] INTERNATIONAL ORGANIZATION FOR STANDARDIZATION. Measurement of fluid flow by means of pressure differential devices inserted in circular-cross section conduits running full Part 4: Venturi tubes. ISO 5167-4:2003. Geneva: International Organization for Standardization, 2003 [2] MURDOCK, J. W. Two-Phase Flow Measurements with Orifices, Journal of Basic Engineering, Vol 84, pp 419-433, 1962. [3] CHISHOLM, D. Flow of Incompressible Two-Phase Mixtures through Sharp-Edged Orifices, Journal of Mechanical Engineering Science, Vol 9, No. 1, 1967. [4] CHISHOLM, D. Research Note: Two-Phase Flow through Sharp-Edged Orifices, Journal of Mechanical Engineering Science, Vol 19, No. 3, 1977. [5] De LEEUW, H. Liquid Correction of Venturi Meter Readings in Wet-Gas Flow, in Proc. of 15 th North Sea Flow Measurement Workshop, Norway, paper 21, October 1997. [6] STEWART, D. G. Application of Differential Pressure Meters to Wet Gas Flow, in Proc. of 2 nd International South East Asia Hydrocarbon Flow Measurement Workshop, March 2003. [7] READER-HARRIS, M. J., HODGES, D., GIBSON, J. Venturi-Tube Performance in Wet Gas Using Different Test Fluids, TUV NEL Report 2005/206, September 2005. [8] READER-HARRIS, M. J. Venturi-Tube Performance in Wet Gas Using Different Test Fluids, in Proc. of 24 th North Sea Flow Measurement Workshop, October 2006. [9] STEVEN, R., KINNEY, J., and BRITTON, C. Liquid property and diameter effects on Venturi meters used with wet gas flows, in Proc. 6 th International Symposium on Fluid Flow Measurement, Querétaro, Mexico, May 2006. [10] STEVEN, R. Horizontally Installed Differential Pressure Meter Wet Gas Flow Performance Review, in Proc. of 24 th North Sea Flow Measurement Workshop, October 2006. [11] AMERICAN SOCIETY OF MECHANICAL ENGINEERS, MFC, Report 19G, Wet gas flowmetering guideline, 2008. [12] STEVEN, R. Wet Gas Metering. PhD Thesis, Department of Mechanical Engineering, Strathclyde University, Glasgow, April 2001. [13] STEVEN, R., BRITTON, C. and STEWART, D. In CEESI Wet Gas JIP Data Release, December 2008. [14] HARRIS, D.M., and SHIRES, G. L. Two-phase pressure drop in a Venturi, in Proc. Two-phase Flow Through Orifices and Nozzles, Report of a Meeting at NEL, 29 th November 1972, NEL Report No 549, Paper 4, East Kilbride, Glasgow: National Engineering Laboratory, 1973. 22