Appliances: Range/Oven/Cooktop Appliance: Corrective Action(s) Finding # 1 **Range anti-tip bracket is not installed. Anti-tip brackets are safety devices installed to prevent the range from tipping forward. Electrical: Corrective Action(s) Electrical: Lights Finding # 2 **Light did not illuminate (Hallway). Electrical: Lights Finding # 3 **An incandescent light was noted in the (MBR Closet). This does not conform to installation practices due to the fact that the bulb could pop and increase a fire risk. We recommend that the light be replaced with a Enclosed or recessed incandescent light or a fluorescent light be installed. Electrical: Receptacles Finding # 4 **The outlet (receptacle) is not ground fault protected (Identified with a Green Label(s) (Kitchen; Rear Patio). Electrical: Receptacles Finding # 5 **The outlet (receptacle) is loose (Identified with a Label(s) (Rear Patio). Electrical: Receptacles Finding # 6 **The ground fault protected outlet (receptacle) was not energize (Identified with a Green Label(s) (Garage).d. Electrical: Receptacles Finding # 7 **The outlet (receptacle) is not energized (Identified with a Label(s) (Garage). Page 1 of 11
Electrical: Wiring Condition Electrical: Corrective Action(s) Finding # 8 **Electrical wiring is not located inside an approved junction box (Exterior North East). We recommend that a licensed electrician correct this condition. Electrical: Wiring Condition Finding # 9 **Extension cord that has been use for permanent wiring should either be removed or replaced with proper wiring (Rear Patio Ceiling Fans). Electrical: Wiring Condition Finding # 10 **The loose electrical conduit should be adequately supported (North East Exterior). Page 2 of 11
Electrical: Wiring Condition Electrical: Corrective Action(s) Finding # 11 **Electrical wiring is not located inside an approved junction box (Rear Patio). We recommend that a licensed electrician correct this condition. Exterior: Corrective Action(s) Exterior: Doors (Including Fire Seperation Doors) Finding # 12 **The self-closing mechanism does not close the door (Rear Patio Door; Garage Service Door). Exterior: Fascias Finding # 13 **Fascia is water damaged/rotted and does not appear to be roof related (South Side; SE Corner). Exterior: Garage Floor % Not Visible Finding # 14 ** Due to homeowner personal belongings we were unable to fully inspect this area. Page 3 of 11
Exterior: Corrective Action(s) Exterior: Garage Wall % Not Visible Finding # 15 ** Due to homeowner personal belongings we were unable to fully inspect this area. Exterior: Wall Covering Finding # 16 **The cracks in the stucco are cosmetic in nature and can be sealed for aesthetics (North Side). Interior: Ceilings Finding # 17 **The ceiling covering material does not meet todays required fire rating. We recommend that the material be replaced with sheetrock of the appropriate thickness for todays fire rating (Garage Ceiling attic access). Page 4 of 11
Exterior: Corrective Action(s) Garage: Corrective Action(s) Exterior: Garage Vehicle Door Opener Finding # 18 **The opener did not reverse when a resisting force was applied to the door while closing. Heating: Corrective Action(s) Heating: Fireplace #1 Finding # 19 **Flue is dirty and should be cleaned prior to use. Heating: Fireplace #1 Finding # 20 **We recommend installing some type of spark arrestor {i.e. mesh screen} on the chimney exit to prevent any embers from escaping the chimney. Insulation: Corrective Action(s) Insulation: Walls Finding # 21 **The insulation is misplaced at the walls in the house attic. Page 5 of 11
Insulation: Corrective Action(s) Interior: Corrective Action(s) Interior: Ceilings Finding # 22 **The ceiling is damaged (Garage). Interior: Doors Finding # 23 **The Closet Door is missing (SW Bedroom). Interior: Stairs/Railings Finding # 24 **Stairway railing is loose. Interior: Windows Finding # 25 **The window latch is not operable (SW Bedroom). Plumbing: Corrective Action(s) Page 6 of 11
Plumbing: Drain, Waster & Vent Piping Plumbing: Corrective Action(s) Finding # 26 **Vent pipe terminates less than the required 6" above the roof surface. Plumbing: Hose Bibbs Finding # 27 **Hose bibb does not have an anti-siphon device (East Side; West Side). Plumbing: Sinks Finding # 28 **Drain stopper is not functional (MBR Bathroom; Lower Level Hall Bathroom). Plumbing: Sinks Finding # 29 ** The sink drain is an unapproved propducts. (Flex PVC) We reccomend using solid PVC drain pipes. Seek further evaluation from a quality licensed contractor for this condition. Plumbing: Tubs Finding # 30 **Tub stopper is missing (MBR Bathroom; Lower Level Hall Bathroom). Page 7 of 11
Plumbing: Tubs Finding # 31 **Tub is corroded (MBR Bathroom). Plumbing: Corrective Action(s) Plumbing: Tubs Finding # 32 **Tub is corroded (Lower level Hall Bathroom). Pool: Corrective Action(s) Pool & Spa: Electrical Finding # 33 **We observed sub-standard wiring at the pool switch junction box. (Exposed wiring) We recommend replacement with wiring that meets approved methods. Pool & Spa: Miscellaneous Finding # 34 ** The pool gate and fence show signs of severe rusting. Seek further evaluation from a quality licensed contractor for this condition. Page 8 of 11
Pool: Corrective Action(s) Pool & Spa: Miscellaneous Finding # 35 ** The self closing hinge on the pool gate does not operate correctly. Seek further evaluation from a quality licensed contractor for this condition. Pool & Spa: Pumps & Motors Finding # 36 **The Pump is leaking. Structural: Corrective Action(s) Structural: Fences & Gates Finding # 37 **The boards/slats of the gate are missing; loose (South Gate). Structural: Fences & Gates Finding # 38 **Gate is difficult to lock/latch (South Gate). Structural: Patios & Decks Finding # 39 **Post is rotted where it contacts the floor/ground (Rear Patio). Page 9 of 11
Structural: Corrective Action(s) Structural: Patios & Decks Finding # 40 **Metal anchor used to secure the post to the ground is missing (Rear Patio). Structural: Patios & Decks Finding # 41 **Metal anchor used to support the post at the ground is corroded (Rear Patio). Page 10 of 11
Electrical: Wiring Condition Finding # 42 ** The open slot needs to be covered to prevent items from entering the area were there are live wires. (Pool junction box) Roof Corrective Action(s) Roof Area #1 Finding # 43 ** Roof edge J channel is missing. Seek further evaluation from a quality licensed contractor for this condition. Page 11 of 11