Douglas County Traffic Signal Installation Guidelines (January 2013)

Similar documents
NORTHEASTERN REMC ELECTRIC STANDARDS MANUAL

NORTHEASTERN REMC ELECTRIC STANDARDS MANUAL

Solar Powered TS1000 Installation Pictures. (Trench and Fill Method) City of Vallejo, CA

SMALL CELL DESIGN GUIDELINES

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

PART 7 COMMUNICATIONS, LIGHTING, TRAFFIC CONTROL, POWER

GENERAL NOTES PEDERNALES ELECTRIC COOPERATIVE, INC. RESIDENTIAL AND COMMERCIAL AMP METER LOOP SPECIFICATIONS

A. Product Data shall be provided for each type of product indicated.

Public Works Division Lighting District Supplemental Specifications For Solar School Flashing Beacon Installation March 2007

TEMPORARY FACILITIES

CHAPTER 13 GROUNDING AND BONDING

CITY OF MOUNT DORA LIFT STATION CHAINLINK FENCE AND GATE SPECIFICATIONS

OVERHEAD SERVICES - SECONDARY

RESIDENTIAL QUICK REFERENCE

SECTION 1101 TRAFFIC SIGNALS AND APPURTENANCES END OF SECTION

SECTION 1208 CHAIN LINK FENCING DESCRIPTION

ITEM L-119 AIRPORT OBSTRUCTION LIGHTS DESCRIPTION

12/21/2018 WHAT S NEW SINCE What's New Since SPEC BOOK 2018 SPEC BOOK 2018 SPEC BOOK WHAT S NEW SINCE 2014

Huntsville Utilities Underground Residential Service Requirements

STREET LIGHTING GENERAL INFORMATION

Section 2: Underground

OVERHEAD SERVICE. Table of Contents - Section 400

ITEM 555 CHAIN LINK FENCING

3. Intermediate metal conduit (IMC). 4. Electric metallic tubing (EMT). 5. Flexible metal conduit (FLEX). 6. Polyvinyl chloride conduit (PVC).

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

WOOD POLE SPAN WIRE SIGNAL SYSTEMS

6. SECONDARY SERVICES (under 600 volts) 6.1 AVAILABILITY For the electrical characteristics of available secondary services see Section 3.4.

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION CHAIN LINK FENCING

OVERHEAD SERVICES - RESIDENTIAL & GENERAL SERVICE. See Chapter 3, Section 3.01 for more information about point of entrance (POE).

CONSTRUCTION STANDARDS SECTION CS 15 STREET LIGHTING

WIRING RULES AND REGULATIONS OF TOMBIGBEE ELECTRIC POWER ASSOCIATION

CONTENTS. B. System Design and Performance Requirements

UNDERGROUND SERVICES SECONDARY

Please check with your local inspection authority for any additional requirements before installation.

Section 7: Specifications

General Symbols, Ducts and Cables

1/5/2018 WHAT S NEW SINCE B & B QUALIFICATION OF WORKERS. What's New Since SPEC BOOK 2018 SPEC BOOK 2018 SPEC BOOK

Contact Clark Public Utilities Construction Services department at (360) to initiate a request for service.

UNDERGROUND SERVICES (RESIDENTIAL) SINGLE FAMILY RESIDENTIAL, DUPLEXES, OR TOWNHOUSES

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF POWER SUPPLY EQUIPMENT

OPERATING PROCEDURE NO. 310

Effective June, Eaton-Durham Model # UTRS223ACH. Siemens, Model # SUAS877-PG. (or Landis & Gyr # UAS877-PG) Milbank. Model # U1980-O.

General Symbols, Ducts and Cables

TS 805 POLES TTS CONSTRUCTION SPECIFICATION FOR POLE INSTALLATION TTS MATERIAL SPECIFICATION FOR STEEL POLES BASE MOUNTED

SECTION GROUNDING AND BONDING

ROOF MOUNT KIT OWNERS MANUAL

2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING

(Condensed from National Electric Code)

General Symbols, Ducts and Cables

SECTION CHAIN-LINK FENCES AND GATES 02821/1

SECTION GROUNDING

GLENWOOD PLACE 2 MAR 2015

Underground Exhaust System

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

ROOF MOUNT KIT OWNERS MANUAL

GV 001 Equipment Bases and Enclosures General Information

TITLE: CAMP JOHNSON OVERPASS / HWY 17 BYPASS SECURITY FENCE UPGRADES

SECTION CONDUITS AND BOXES

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF ROADWAY LUMINAIRES

CONSTRUCTION SPECIFICATION FOR GROUNDING

SECTION ELECTRICAL SITE UTILITIES

ASTM C857 A -16 AASHTO H -20 (for vaults beneath roadways) ASTM C857 A-8 (for vaults beneath incidental light truck traffic)

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DISTRIBUTION EQUIPMENT

ZG Scope. 2 Applicable Documents. 3 General. 4 Stock Item Numbers. Padvault Single-Phase Residential, 2.1 PacifiCorp Material Specifications

SECTION GROUNDING AND BONDING FOR ELECTRONIC SAFETY AND SECURITY

CONSTRUCTION SPECIFICATION FOR TRAFFIC ACTUATION EQUIPMENT

INSTALLING A POUR-IN-PLACE DOCK LEVELER (EH & RR)

6. SECONDARY SERVICES (under 600 volts) 6.1 AVAILABILITY For the electrical characteristics of available secondary services see Section 3.4.

SECTION CHAIN LINK FENCES

Mounting Screw. Channel Filler. Light Angle Adjustable Screw. LED Board Vertical stud and blocking Locking Nose. Driver.

CONSTRUCTION SPECIFICATION FOR POLE ERECTION

TYPICAL INSTALLATION INSTRUCTIONS

A. All materials shall be tested and listed by an OSHA approved Nationally Recognized Testing Laboratory (NRTL).

Colorado River Aqueduct Pumping Plants 230 kv Disconnect Switches Replacement

SPECIAL SPECIFICATION 6664 Level (3) Communications System

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

400 watt, high pressure sodium. Type C watt, high pressure sodium Collector Street Light Units

SPECIAL SPECIFICATION 6658 Time Warner Communications System

SECTION GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS

Rough-in frame and flush-mount panel installation instructions

SECTION CHAIN LINK FENCING

STANDARD DRAWINGS. September 2013 UPDATED FEBRUARY 2016

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF ROADWAY LUMINAIRES

Basic Service. This Section provides information regarding a. Introduction

UNM IT/Telecommunications Guide Specification Communications Underground Ducts, Raceways and Structures /27/06

UNIVERSITY OF MISSOURI Electrical Manholes and Handholes 2016 Q1

SECTION CONDUITS AND BOXES PART 1- GENERAL. A. Work covered by this section includes the furnishing and installation of conduits and boxes.

ELECTRICAL SERVICE UPGRADE RESIDENTIAL AND COMMERCIAL QUICK INFORMATION REFERENCE

Aegis Heavy Capacity 20K Floor Scale. MODEL: 6200 Series. Installation Manual

SECTION METAL STAIRS

SECTION CHAIN LINK FENCING

UNDERGROUND SERVICES - GENERAL SERVICE AND MULTI-UNIT RESIDENTIAL

SECTION CHAIN LINK FENCES AND GATES (PARK)

CONSTRUCTION SPECIFICATION FOR STEEL BEAM GUIDE RAIL AND CABLE GUIDE RAIL

Modular CABANA Kit 16 x 16 (6x6) Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16" long / 1/2" thick or 16 oz. copper

MERCHANTS METALS. A. ASTM F552 Standard Terminology Relating to Chain Link Fencing

CONDUITS AND FITTINGS

Repair Maintenance Hangar Phase II August 2010 SECTION LIGHTNING PROTECTION SYSTEM PART 1 GENERAL

SPECIAL SPECIFICATION 1924 Neighborhood Friendly High Mast Illumination System

[Type text] Heber Light & Power. Developers & Excavators. Electrical Service Requirements Manual

Transcription:

Douglas County Traffic Signal Installation Guidelines (January 2013) The following guidelines are minimum requirements for equipment installation. Section A. Poles and Foundations ( Wood, Concrete, Mast Arm, Or Steel Pole) 1. Poles are to be staked by the prime contractors surveyor on the same day that the prime or sub contractor intend to install foundations. If you intend on coming back the following day to install a foundation, the surveyor must come back out and restake the remaining pole locations as well OR you may drive metal fence post 12 into the ground and only leave 3 above ground and paint it orange. This method will not allow a person to remove your staking device. (If the contractor does not adhere to this method the contractor may face pulling and reinstalling a pole at a later date if the pole does not meet design criteria or falls off of right away). 2. All Mast Arm / steel pole foundations are to be poured continuously until each foundation is complete. A concrete test sample may be taken by Douglas County or GDOT personnel. NO partial pour foundations are accepted. All concrete foundation work is to be vibrated as it is being poured. Splices Inside of Poles 1. Splices are not permitted inside Mast Arm Poles unless directed to do so by Douglas County Traffic Signal Unit. Placement of Signal Equipment on Poles and Spanwire 1. Contractors must schedule a time with Douglas County Signal Unit to be onsite and designate all signal head/equipment locations on both Mast Arm and Spanwire signal installations. This includes any video detection equipment, signage, signal heads, and antennae. Wiring of Signal Heads and Equipment 1. Signal wire must run continuously from the cabinet to the furthest left head for any phase intended to be used. It shall then be placed onto a terminal block and then a jumper wire is used to go to the subsequent signal head. If (2) wires go under the same screw terminal they must be crimped into the same fork connector and then screwed under the same terminal location.

Section B Spanwire Installations 1. Spanwire intersections are to have bullring placements along with signal head placement designated by Douglas County Personnel. Contractors must schedule a time for Douglas County personnel to be onsite and site in this equipment. 2. Currently there is only one approved method for attaching signal wire to spanwire. Contractors must use Black UV resistant Heavy gauge tiewraps placed every 8 apart from each other.wiring must be kept straight and neat throughout the installation. 3. 7/8 x 5 ½ round weldless galvanized powder coated bullrings are required for ALL spanwire installations. ( no oval bullrings permitted) Section C. Pullboxes 1. Pullboxes are to be flush with surrounding grade and have 1 gravel inside as well as under the box for drainage purposes. Examples A. and B. below A. B. Section D. Conduit 1 Conduit in pullboxes is to come into pullboxes (excluding fiber runs) completely vertical and be gray conduit.the Distance between any conduit riser in a pull box and the lid is not to be closer than 6 at any time. All couplings are to be glued thoroughly. Refer to examples A.and B. above. 2. Directional bore conduit is NOT allowed to come directly into a pullbox unless the conduit is specifically for Fiber Optic Cable. The conduit must first terminate and a 90 degree turn must come up into a pullbox using gray conduit. When terminating a directional bore conduit and connecting a PVC conduit or elbow the only approved method to connect these different types of conduit is a solid aluminum serrated coupling that bites into both types of conduit. See example photo D 2 a) 1 and 2 sizes are available

Section E. Signal Heads 1. Signal heads are sighted in only by Douglas County Traffic Signal Personnel. Contractor personnel MUST use terminal blocks inside all signal heads to wire up signal heads. All connections that are to be jumpered to additional signal heads of the same phase,shall be from the furthest left head of the phase first, crimped together in the same terminal fork and then attached to a terminal block. 2. Signal heads are to be NO lower than 18 unless special conditions exist. Signal heads are to be NO higher than 20. Section F. Cabinet Bases 1. Cabinet bases SHALL be buried to a depth of no more than 8. The cabinet base shall be 90 degrees to the main street at all times. Battery Backup Equipment SHALL always face away from the roadway.cabinet doors shall always swing away from the roadway and NOT block the vision of a signal technician. 2. Locating a cabinet base at a 45 degree angle is NOT permitted 3. All cabinet bases Shall be BBS ready, one piece units that provide a mounting platform for BBS/UPS systems.

Section G. Cabinet Wiring 1. Cabinets shall be wired so that all wiring comes up to the access hole in the base and is still covered with black outer jacket on the wires. Each phase, ped, and loop wire shall be clearly and neatly marked as well as the neutral wire for each phase, any ped indication terminating on the on the neutral bus bar should have a number that corresponds to which phase it belongs to. See example C. below. Example C.Notice that the wiring is cut to length and neatly terminates on each terminal. This is the only accepted method for wiring the cabinet.

Section H. Loops 1. All loops are to be marked on the asphalt by temporary means. Temporary means can be temporary marking paint or chalk or other temporary means. Example D.Below 2. Loops are to be wet sawcuts. 3. Loops are to be cut at a precise depth of 3 into the asphalt or concrete. 4. Loops are to be perfectly straight lines. Example E. Below 5. Loops are to be sealed using Chemque sealant or approved equivalent and are NOT to exceed the sawcut. It is recommended to stop sealant at 1/8 from the top of any sawcut to prevent excessive sealant on the asphalt. Example F Below. 6. Each loop is to have its on lead in individually cut to the edge of the curd and drilled through the curb. Example G Below. 7. The nose of a loop should exceed the stop bar by only 24 at a maximum. Unless directed to by DCDOT staff. Example H. Below 8. Loops shall have precise cuts in all corners that are equal and a consistent depth for loop turns to be made. Typically the distance for a minimum cut is ½ of the sawblade at any corner of the loop. This keeps loop wires at a consistent depth through turns. Example I is a correct corner cut. Example J. is a poor cut example. Example J. will result in recutting the entire loop. Example D.. loops properly marked and straight cuts

Example E. Perfectly straight sawcuts at 3 depth Example F. Sealant being installed without spillage.

Example G. Each lead in has a separate cut out to the curb and are drilled through the curb. Example H. The nose of a loop passing the stop bar by only 24.

Example I. This is a properly cut loop with proper turn cuts for loop wire. Example J. This is an example of a poorly cut loop at turn points. This will result in re cutting the entire loop.

Section I. Installation of Metering equipment and disconnecting equipment. Below is a diagram from the local EMC power company clearly showing the route that power must go through to enter the signal cabinet and all appropriate measurements. Power must first be routed to the service disconnect. Next, the power must enter the meterbase. Finally the power should route into the traffic signal cabinet. The use of a disconnect after the meterbase is NOT allowed. A 60amp fuseable service disconnect shall be mounted no less than 16 below a transformer on a utility owned pole. If mounted on the signal pole then ask signal superintendent for proper mounting height to attach the disconnect. The meterbase shall be mounted so that the meter socket does not exceed 50 from ground level. Example A. Utility power diagram sheet.

The meterbase shall be a 200amp meterbase with built in bypass switch. Wiring inside the meterbase shall be ran so that all wiring is clearly visible and NOT twisted around each other.example B. below demonstrates proper wiring of the meterbase. BLACK 6awg stranded copper wire is used for HOT wire and WHITE 6awg stranded copper wire is used for neutral wire runs. Example. B. proper wiring of a meterbase

Section I. School Flasher Equipment School Flasher / Pedestrian Foundations 1. Foundations shall be Class A concrete poured into a round 24 diameter x 24 depth Sonotube form. 2. The Sonotube form shall be fastened to a square wood frame and wooden stakes securely fastened to the wood form to prohibit ANY movement of the Sonotube. 3. The concrete shall be electrically vibrated so all air pockets are removed. 4. 18 deep x ¾ anchor bolts shall be used to secure the ped base to the concrete and installed in the concrete PRIOR to the cement being poured. The cement shall be smooth across the top. 5. 1, 2 conduit and 1, 1 conduit shall be installed inside the ped foundation and run continuously to the nearest Type 1 Pullbox where a ground rod shall be installed. 6. All conduit are to be located at the center of the foundation and come out of the cement at 90 degrees to the ground. (no crooked pipes). School Flasher construction 1.Place octagonal ped base on cement foundation. 2. Place aluminum ped pole into base and COMPLETELY tighten and secure the pole into the base with the use of a CHAIN STRAP until the pole no longer rotates. 3. Locate a point 50 off of the ground and drill out the pole and install a 1 rubber grommet so that the rubber grommet faces opposite of oncoming traffic. This is the point at which the School Flasher cabinet wiring will be fed through. 4. Locate a point approximately 10 above ground and mark the pole. This point represents the bottom of the lowest signal indication. 5. Near the top of the pole drill out the pole and install a 1 rubber grommet for necessary wiring to pass through. 6. Route wiring from the flasher assembly down the pole and out of the previously drilled hole in the pole. 7. Pull wire out of the pole and into the cabinet. Mount and secure the cabinet to the pole. 8. Attach the school flasher assembly to the pole by use of the provided clamping pipe assemblies.

9. Near the top of the pole drill out a 1 hole and install a 2 nd 1 rubber grommet. This grommet is to be used for routing RTC antennae wire through later. 10. On the nearest wooden utility pole mount the 200 amp meterbase w/bypass switch as indicated in the attached document provided by the Utility company. Wire the meterbase as indicated earlier in this document in SECTION I. The completed installation should resemble the assembly below.