Fully Extractive Vs. Dilution Extractive CEMS

Similar documents
Maintaining Continuous Emissions Monitoring Systems To Achieve High Reliability. a technical solution to meet every need

Continuous Emissions Monitoring Systems. Engineering & Design. For PetroChem Processes

A Higher Standard of Monitoring Systems & Customer Service

CEMS for Measurement of Ammonia, SO 3, and Low Level NOx

CONTINUOUS EMISSION MONITORING SYSTEM. Copyright Adage Automation Pvt Limited

John Downs Environmental Manager, B&W PGG, KVB-Enertec Products. January 29, 2015

Continuous Emissions Monitoring Systems. Engineering & Design. For PetroChem Processes. a technical solution to meet every need

TruePeak TDLS200. NH 3 Slip Measurement. <Document Number> Copyright Yokogawa Electric Corporation <date/time>

A global monitoring systems offering. A world of advantages. Thermo Scientific Continuous Emissions Monitoring Systems

Cross-effects and total gas clean-up system lay-out

SCR Control Strategy and CEMS for an Ultra-Low NO x Emitter

: Industrial Boiler MACT: CEM Requirements. Dan Kietzer: SICK Process Automation

Continuous Emissions Monitoring in Support of the Cement MACT

Combustion Control and Safety A comparison between Zirconium Oxide/Catalytic and Tunable Diode (TDL) Technologies Dr Stephen Firth / Rhys Jenkins

Common CEMS RATA Failures and Risks. Paula Metz Alliance Source Testing, LLC Technical Services Assistant Manager

Sampling Technology for Extractive CEMS & Maintenance Issues of CEMS Sanjeev Rai Perma Pure Aug 9, 2016

WHITEPAPER: AMMONIA MEASUREMENT FOR COMBUSTION SOURCES

Online Infrared Flue Gas Analyzer Gasboard 3000

Trace HCl measurements in coal-fired power plant emissions using Cavity Enhanced Laser Absorption Spectroscopy

Energy Production Systems Engineering

Fpollutant-free zero air for analytical

Continous Emission Monitoring: Methods, Regulations and QA/QC. Anders Arvidsson, Opsis AB, Sweden

ABB Measurement & Analytics Monitoring cement plant stack emissions using FTIR

ABB Measurement & Analytics Trace HCl measurements in coal-fired power plant emissions using Cavity Enhanced Laser Absorption Spectroscopy

PPC specializes in maximum efficiency air pollution control equipment using a variety of different

Particulate CEMs for Wet and Dry FGD applications. By William Averdieck, Managing Director, PCME Ltd, UK

New Requirements for the Measurement of Ammonia Emissions

PRODUCT CONFORMITY CERTIFICATE This is to certify that the

CANADA UNISEARCH founded in 1980

Measurement of Space-Heating Emissions. Prepared for:

Field Test Program to Evaluate Mercury Emissions from Coal-Fired Facilities with SCR-FGD Systems

Analysis systems. Analysis system for CO, Nox, O2, T. Analysis systems for CO, O2, T multiplexing, OPC

Gas Turbine Inlet Air Cooling System

Stack Sampling. requires airflow through the sampling probe to be at the same rate as that flowing in the waste gas stream isokinetic

Sorbents Evaluation Testing Facilities. 95% removal efficiency or an emission standard of lbs/gw h by 2012, while

Monitoring cement plant stack emissions using FTIR

Catalytic Activated Ceramic Dust Filter a new technology for combined removal of dust, NOx, dioxin, VOCs and acids from off gases.

Can your unit pass a Particulate Emission Compliance Test?

Mercury Monitoring in a Cement Kiln

Process Analytics Using Quantum Cascade Laser

Minimizing Ammonia Consumption in DeNOx Plants In situ Laser Gas Analyzer LDS 6 Monitors NH 3 Slip in Real-time

Chapter 9 Emission Measurement, Monitoring & Reporting

Acid Gas Control Systems. Spray-Dry Scrubbers and Dry Injection Systems. United McGill products. a McGill AirClean product

TUV Certified FTIR CEM and Ultra Low Level HCl CEM for Combustion Facilities

Analyzer Module Wet Chemiluminescence Detection (WCLD)

SCR for NO x Control in Coal-fired Power Plants

PORTABLE FLUE GAS ANALYZER

Portable Infrared Flue Gas Analyzer Gasboard 3800P

POWER PLANT AIR QUALITY CONTROL and FLY ASH QUALITY & AVAILABILITY

Technical Guidance Note (Monitoring) Medium Combustion Plant Directive and Generator Controls: monitoring point source emissions

Worldwide Pollution Control Association

GAS ANALYZERS. Digital Manometer

ASI MODEL DM 100 SERIES DILUTING MODULES

Standard Continuous Emissions Monitoring System (CEMS)

EPA vs. EN standards

Accurate determination of trace elements emissions using AFS. Dr Warren Corns. Coal Research Forum 2016 PSA. Slide 1

Industrial Gas Analyzers in Applications Information

Diode laser analyser LS4000 Ammonia slip measurement for DeNOx process

Multipoint Probes to Mitigate Stratification CEMTEK Users Meeting. September 28 th, 2016

Advances in NOx Compliance Testing with Portable Electrochemical Analyzers

W P C A. Worldwide Pollution Control Association. WPCA-Duke Energy FF/HAPS Seminar October 12-13, Visit our website at

Mercury Monitoring Technologies and Detection Principles

Performance Tests & RATAs. Our Mission: To protect and improve the health and environment of all Kansans

Continuous Emissions Monitoring (CEMS) Package With NGA 2000 Analyzers

Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000

CEMENT PLANT ENVIRONMENTAL TECHNOLOGY FOR ACHIEVING HIGH SO 2 REMOVAL

Mercury CEMS Sample Line Temperature Reduction Study

Worldwide Pollution Control Association

Process Analytical and Continuous Emissions Monitoring Systems

PRODUCT CONFORMITY CERTIFICATE

Overview of Mercury Monitoring Technologies and Regulatory Requirements

Control Device Technology

Advanced AQCS for Oxy-fuel Combustion System; Controlling Mercury & SO3

Drying of High-Moisture Coals For Power Production & Gasification

Worldwide Pollution Control Association

PM Compliance Options for MACT and MATS Rules. Ed McCall PCME

Mercury and SO3 Mitigation Issues for Scrubber Technology

Process Optimization & Plant Safety

Coal Fired Boiler Optimization and the Impact on Emission Control Devices

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

VOLATILE ORGANIC COMPOUNDS

Gas Flow How to Improve It to Enhance ESP, Boiler, FGD, SCR, SNCR Performance

Worldwide Pollution Control Association

EMO August 1, Bobby I.T. Chen Client Program Manager

Difficult CEMS Applications at Refineries & Chemical Plants

Comparison Continuous Emission Monitoring Techniques

This document is a preview generated by EVS

The Proper Mechanism for Field Validating Moisture Analyzers. GE Measurement & Sensing GE Oil & Gas

Continuous Mercury Monitoring at Cement Plant

Worldwide Pollution Control Association. August 3-4, 2010

Environmental Policies. Bruce Rising Siemens Westinghouse

Plasma-based cleaning of exhaust gases of combustion Plasma based cleaning of exhaust gases of combustion(wp4)

Tunable Diode Laser Technology. Direct Adsorbtion

Compliance Monitoring Using Continuous Emissions Monitoring Systems (CEMS)

Analysis campaign for measurement of oxy-combustion flue gas from Coal Fired Plants

Guidance for Portable Electrochemical Analyzer Testing Used for Compliance Monitoring

natcom burner solutions Advanced burner technology for stringent emissions requirements

State of the Art (SOTA) Manual for Stationary Gas Turbines

PRODUCT CONFORMITY CERTIFICATE

Transcription:

Fully Extractive Vs. Dilution Extractive CEMS Cemtek Environmental Emissions Seminar & Training Session Santa Ana, CA a technical solution to meet every need CEMTEK Environmental Inc. 3041 S. Orange Ave. Santa Ana, CA 92707 800-400-0200 www.cemteks.com

Continuous Emission Monitoring CEMS are required for a variety of different applications and can be found at facilities such as: Turbines-Gas & Oil Fired, Boilers-Gas, Oil & Coal Fired, IC Engines-Landfill Gas, Wastewater Treatment-Sewage Sludge Incinerators & IC Engines, Refinery, Waste to Energy, Cogeneration & Process Applications

CEMS & Process Monitors Ambient, Dilution, Full-Extractive Dry, Hot-Wet Extractive Chemiluminescence, Fluorescence, NDIR, GFC, Zirconia, Paramagnetic, Tunable Diode Laser, Heated FID (Flame Ionization Detection) and FTIR Low NOx/NO/NO 2 /NH3/SO 2 /SO 3 /CO/CO 2 /O 2 /VOCs, Mercury, Opacity, Flow, Ozone, Calibrators and PM

CEMS TYPES FULLY EXTRACTIVE (DRY BASIS) DILUTION EXTRACTIVE (WET BASIS) OTHERS: FULLY EXTRACTIVE (HOT/WET) IN-SITU (CROSS STACK or PROBE) EX-SITU (CLOSE COUPLED EXTRACTIVE)

FULLY EXTRACTIVE - Dry Basis Sample Gas Dried To A Dew-point Of +2 C Excellent Performance In Low Concentrations Good Performance In High Concentrations Requires Preventative Maintenance MEASUREMENT TYPES: Chemiluminescence, NDIR, UV Absorption, UV Fluorescence, Paramagnetic, Zirconia, FTIR, DOAS, IR-GFC Heated Probe Filter And Heated Sample Line Moisture Volume Needs to be Determined Constant or Measured

Sample Line Probe NOx Pump Cal Gas Inst. Air Cooler CO O2 Extractive Flow Schematic

SAMPLE CONDITIONING BAY

SAMPLE COOLER SAMPLE PUMP PERISTALTIC PUMP

Fully Extractive Heated Probe

SYSTEM CONTROL PANEL SAMPLE FLOW CONTROL PANEL

SAMPLE PROBE WITH HEATED FILTER

DILUTION EXTRACTIVE - Wet Basis DILUTES SAMPLE WITH CLEAN DRY AIR MINIMIZES MAINTENANCE USES HIGHLY SENSITIVE GAS ANALYZERS LOWER COST SAMPLE LINE FREEZE PROTECTED SIMPLE TO OPERATE MEASUREMENT TYPES: Chemiluminescence (NOx), UV Fluorescence (SO2), GFC-IR (CO), NDIR (CO2 diluent)

Dilution Extractive Flow Schematic

Blow Back Cal Bypass Dilution (purge) Gas Air Air Stack Vacuum Pressure Comp Diluted Sample Out DILUTION PROBE SCHEMATIC (Out-Of-Stack)

Side View Pressure Comp Cal Gas Vacuum Dilution Air Diluted Sample Out DILUTION PROBE ARRANGEMENT (Out-Of-Stack)

Bypass Air Top View Heated Filter DILUTION PROBE ARRANGEMENT (Out-Of-Stack)

Heated Block Bypass Air Blow Back Air DILUTION PROBE ARRANGEMENT (Out-Of-Stack)

DILUTION CONTROL PANEL GAS ANALYZERS

TRACE GAS SCRUBBERS ACCUMULATOR TANK HEATLESS AIR DRYER

CEMS SELECTION AND DESIGN Application Choices Dilution or Extractive Pollutant Concentrations Lowest constituent dictates May preclude dilution due to analyzer limitations Mass Emissions Requirement Dilution is a wet basis measurement Requires flow measurement

APPLICATION CHOICES Dilution or Fully Extractive Advantages Disadvantages Dilution Low maintenance Low concentrations Extractive More reliable (Ratios above 100:1) Coal fired Some oil fired Fully Low concentrations Higher maintenance Extractive Gas fired Lower availability Some oil fired Fuel flow meter

Continuous Emissions Monitoring Systems Engineering & Design Gas Turbines a technical solution to meet every need CEMTEK Environmental Inc. 3041 S. Orange Ave. Santa Ana, CA 92707 800-400-0200 www.cemteks.com

Gas Turbine Process Diagram Turbine Exhaust CEMS NO X CO O 2 NH 3 * SCR Inlet CEMS NO X Raw Material Dryer THC Regulatory Compliance CEMS Process CEMS

Natural Gas Fired Turbine Gas Turbine Air Quality Control Systems CO Catalyst SCR NO X Control

Conventional CEMS Ammonia Slip Measurement Techniques Differential NO X /NH 3 Converter Method Turbine Exhaust NO X + Converted NH 3 Turbine Exhaust NO X On Stack Converter 4 NH 3 + 5 O 2 = 4 NO + 6 H 2 O *High temperature catalyst NH 3 slip (ppm) = NO X (ppm) (total converted) NO X (ppm) (unconverted)

Conventional CEMS Ammonia Slip Measurement Techniques Inlet/Outlet Differential NO X Method Turbine Exhaust NO X SCR Inlet NO X NH 3 slip = NH 3 fed (NO X in NO X out)

Direct NH 3 Measurement Method Conventional CEMS Ammonia Slip Measurement Techniques Turbine Exhaust NH 3

Continuous Emissions Monitoring Systems Engineering & Design Coal Fired Utility Boilers a technical solution to meet every need CEMTEK Environmental Inc. 3041 S. Orange Ave. Santa Ana, CA 92707 800-400-0200 www.cemteks.com

Coal Fired Utility Boiler Process Diagram SCR/SNCR NO X NH 3 Slip Stack Exhaust CEMS NO X Regulatory Compliance CEMS FGD Inlet SO X Compliance/Process CEMS SO 2 CO PM Hg HCl Flow Process CEMS

Coal Fired Utility Boiler Air Quality Control Systems SCR/SNCR NO X Control Activated Carbon Injection Mercury Control Particulate/ Opacity Control WFGD/DFGD SO X Control

Wet & Dry FGD CEMS Application CEMS Design Considerations Coal Fired Boiler FGD Scrubber General CEMS Design Probe Design and Accessories Corrosion resistant materials for probe tube construction to prevent attack from acid gases (Hastelloy, Inconel, etc.) Heated probe tube in wet stack (saturated) conditions to help prevent corrosion Impingement shield on probe inlet to prevent clogging from wet particulate Demisters to knock down entrained water in sample prior to entering dilution orifice Probe accessibility for maintenance and service Stack clearances for probe installation and removal Temperature effects on the density of the flue gas minimized by the use of a heated orifice

Wet & Dry FGD CEMS Application CEMS Design Considerations Coal Fired Boiler FGD Scrubber General CEMS Design Sample Umbilical l Design Sample line routing and access. Keep in mind access for stack testers and maintenance personnel. Test Port ot Heated umbilical for low dilution ratios (higher moisture concentrations) Heated umbilical for low CO measurement applications in conjunction with stainless steel tubing

Wet & Dry FGD CEMS Application CEMS Design Considerations Coal Fired Boiler FGD Scrubber General CEMS Design Dilution Air Cleanup Design Plant air cleanup panel to condition air to instrument grade may be required Redundant dilution air cleanup for added system availability CO and trace gas scrubbers for removal of measured gases CO 2 Adsorbers & Trace Gas Scrubbers CO Scrubbers