NEW HARMONI (3mm) Technical Specification Sheet

Similar documents
SECTION and/or Resilient Sheet Flooring and/or Resilient Tile Flooring

SECTION Rubber Tile Flooring

Advance NG (6mm) Technical Specification Sheet

SECTION and/or Resilient Sheet Flooring and/or Resilient Tile Flooring

Sport Impact (10mm) Technical Specification Sheet

Harmoni (3 mm) Technical Specification Sheet

MondoArmor (18mm) Technical Specification Sheet

SECTION Resilient Athletic Flooring

1.02 RELATED REQUIREMENTS NOTE:

1.02 RELATED REQUIREMENTS NOTE:

Control XT SECTION Resilient Athletic Flooring

Division 9 Resilient Athletic Flooring

Performance Rolls GUIDE SPECIFICATIONS Manufactured in the U.S.A. by:

Powerdek Fleck. SECTION Resilient Athletic Flooring

SECTION Resilient Athletic Flooring

UPOFLOOR Quartz Tile Architectural Guide Specification CSI/CSC Section Format [3-part] CSI Page Format

CSI Exceed PART 1.0 GENERAL. plae.us SUMMARY 1.2 REFERENCES

ECOfit Rolls GUIDE SPECIFICATIONS ECORE Commercial Flooring

GUIDE SPECIFICATIONS IN CSI FORMAT: RESILIENT FLOORING

Ecore Athletic Elevate BOUNCE 2 GUIDE SPECIFICATIONS Ecore

Training Ground with Nike Grind RubberX GUIDE SPECIFICATIONS Ecore

CONNOR Control XT Page 1

ECOfit Rolls GUIDE SPECIFICATIONS Ecore Commercial Flooring

Everlast Basic Rolls and Tiles GUIDE SPECIFICATIONS Ecore

RESILIENT FLOORING: Select Step Wood

1. Amarco Products Athletic Recycled Rubber Sports Flooring Rolls and Interlocking Tiles 2. Adhesives

1. CONCRETE SUBFLOORS.SECTION a. Slab Depression: Equal to thickness of selected flooring (6, 8,10,12,13 or 14mm).

RESILIENT FLOORING: Hot and Heavy - Secoya

Fastrack Rolls and Interlocking Tiles GUIDE SPECIFICATIONS Centaur

FOREST RX / TERRAIN RX GUIDE SPECIFICATIONS ECORE COMMERCIAL FLOORING

Division 9: Section RESILIENT ATHLETIC SURFACING (Regupol AktivLok Recycled Rubber)

Pinnacle 2 Carpet Tile GUIDE SPECIFICATIONS Ecore

ARCHITECTURAL GUIDE SPECIFICATIONS - DESCRIPTIVE

Regupol Aktiv RESILIENT ATHLETIC SURFACING REGUPOL RECYCLED RUBBER

Ecore Athletic Stacked Performance Collection Rolls and Interlocking Tiles GUIDE SPECIFICATIONS Ecore

CONNOR PowerDek Page 1

Vinyl Rx GUIDE SPECIFICATIONS Ecore Commercial

MONDO MP 1000 ACRYLIC ADHESIVE DISCLAIMER: Refer to page 5 of this document.

The complete installation of a prefabricated rubber sports surface including adhesive and game line striping as manufactured by Connor Sports Flooring

Section RESILIENT TILE FLOORING INCLUDING ECONATURALS RUBBER FLOOR TILE

The complete installation of a prefabricated rubber sports surface including adhesive and game line striping as manufactured by Connor Sports Flooring

Tennant Company October North Lilac Drive Minneapolis, Minnesota Guide Specification

Ecore Athletic Elevate Roster Interlocking Carpet Tile GUIDE SPECIFICATIONS Ecore

SECTION RESINOUS FLOORING

Regupol AktivPro RESILIENT ATHLETIC SURFACING REGUPOL RECYCLED RUBBER MOLDED TILES

Page 1 of 5 PART 1 GENERAL

A. This section includes pre-finished Higuera Hardwoods bamboo flooring and accessories for floors and stairs.

QT 4003 (3mm), QT 4005 (5mm) & QT 4010 (10mm)

*************************************************************************************

Section STATIC DISSIPATIVE RESILIENT FLOORING

1.2 SUMMERY A. Section Includes: 1. High-Performance Polyurethane Resinous flooring systems. 2. Decorative Polyurethane Resinous flooring systems.

GUIDE SPECIFICATIONS IN CSI FORMAT: RESILIENT FLOORING

1. ASTM D412 Standard Test Methods for Vulcanized Rubber and Thermoplastic Rubbers and Thermoplastic Elastomers-Tension.

A. Section Cast-in-Place Concrete: Concrete subsurface. A. ASTM D Standard Test Methods for Rubber Property Compression Set.

RESILIENT CORK TILE 3 PART SPECIFICATION #Z 624

ECOrx GUIDE SPECIFICATIONS Ecore

Section RESILIENT SAFE-T VINYL SHEET FLOORING

Section RESILIENT TILE FLOORING INCLUDING SOLID VINYL FLOOR TILE

SECTION (09620) - RESILIENT ATHLETIC FLOORING

PRODUCT GUIDE SPECIFICATION

.2 Section Waste Management and Disposal. 1.2 REFERENCES.1 Codes and Standards referenced in this section refers to the latest edition thereof.

ECOnights Rolls and Tiles GUIDE SPECIFICATIONS Ecore Commercial Flooring

CONDUCTIVE RESILIENT FLOORING

ECORE Athletic Stacked Ultimate Turf Rolls GUIDE SPECIFICATIONS ECORE International

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SECTION RESILIENT ATHLETIC SURFACING. B. Related Sections: Section(s) related to this section include:

RESILIENT PHOTOLUMINESCENT STAIR TREADS

Section SECTION RESINOUS FLOORING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

RESILIENT ECO NATURALS, DEFIANT, AND PHOTOLUMINESCENT STAIR TREADS

Section RESILIENT TILE FLOORING INCLUDING VINYL COMPOSITION TILE

CONDUCTIVE RESILIENT FLOORING

SECTION ATHLETIC AND RECREATIONAL SURFACING. A. ASTM C 67 - Standard Test Methods for Sampling and Testing Brick and Structural Clay Tile.

Product Guide Specification Pliteq GenieMat RST-02, RST-05, RST-10, RST-12, RST-15

Chapter 2. Basic practices. Topics. 7 Basic practices. Notes. 2.5 Existing flooring and adhesive residue Job site conditions 8

FLEXMAR 3-Coat High-Build Colored Quartz System

SECTION SUBSURFACE PREPARATION FOR FLOOR FINISHES

American Guild Vinyl Flooring - Steadcrest Collection Installation Instructions

GUIDE SPECIFICATION

System Specification CEM-DYE 250 SYSTEM Division 9 Finishes Section Staining and Transparent Finish

SECTION RESINOUS FLOORING

ECOsurfaces Classic Rolls and Tiles GUIDE SPECIFICATIONS Ecore Commercial Flooring

SECTION ELASTOMERIC LIQUID FLOORING

Suggested Specification for Tri-Patch Versatile Concrete Patching Compound

Product Guide Specification Pliteq GenieMat FF06, GenieMat FF10, GenieMat FF17, GenieMat FF25, GenieMat FF50, GenieMat FF75

GUIDE SPECIFICATION

DIVISION 9 - SECTION ECOSilence Recycled Rubber Sound Underlayment US Patent No. RE 41,945

ARCHITECTURAL SPECIFICATIONS GUIDELINES RUBBER/CORK FLOORING TILES INDOOR APPLICATIONS PRISM & EARTH TILES

SECTION TERRAZZO FLOOR TILE

Sample Specifications

Product Guide Specification

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Technical data noraplan

DIVISION 9 - SECTION QTscu Re-bonded Recycled Rubber Impact Sound Insulation Patent No. RE 41,945

LINOLEUM SHEET FLOORING

RESINOUS FLOORING

SECTION PREFINISHED FSC MAPLE FLOORING. This is a template: edit this specification carefully to suit specific project requirements.

SECTION RESILIENT TILE FLOORING

09652 RESILIENT TILE FLOORING

Transcription:

SECTION 09 65 16 RESILIENT SHEET FLOORING OR SECTION 09 65 19 RESILIENT TILE FLOORING 1 General SPECIFIER NOTE: This Specification has been created to assist in preparing a Project or Master Specification. It follows guidelines established by Construction Specifications Canada (CSC) and can be used with most Master Specifications with simple editing. SPECIFIER NOTE: This Specification describes the resilient flooring system to be installed. The number and title of the section may be changed if the Specifier deems necessary; in any circumstance, it will belong to the general CSC Section 09 65 00: Resilient Flooring. 1.1 SECTION INCLUDES A. Resilient rubber commercial flooring. B. Adhesive and accessories required for installation, maintenance and repair. 1.2 RELATED SECTIONS SPECIFIER NOTE: These sections serve as a guide to what is essential information needed to determine the acceptability of the site conditions required for the installation of resilient flooring and related products. The Specifier may choose to include additional sections he/she deems necessary..1 Section 02 25 00 Existing Material Assessment..2 Section 03 05 00 Common Work Results for Concrete..3 Section 06 05 00 Common Work Results for Wood, Plastics, and Composites..4 Section 07 05 00 Common Work Results for Thermal and Moisture Protection..5 Section 07 10 00 Dampproofing and Waterproofing. 1.3 REFERENCES.1 GERMAN COMMITTEE FOR HEALTH-RELATED EVALUATION OF BUILDING PRODUCTS (AGBB):.1 AgBB: Evaluation of Emissions of Volatile Organic Compounds (VOC and SVOC) from Building Products..2 ASTM INTERNATIONAL:.1 ASTM D412 Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers Tension..2 ASTM D2047 Standard Test Method for Static Coefficient of Friction of Polish-Coated Floor Surfaces as measured by the James Machine..3 ASTM D2240 Standard Test Method for Rubber Property (Durometer Hardness)..4 ASTM D3389 Standard Test Method for Coated Fabrics Abrasion Resistance (Rotary Platform Abrader)..5 ASTM E648 Standard Test Method for Critical Radiant Flux of Floor Covering Systems Using a Radiant Heat Energy Source. R101713 Page 1 of 8

.6 ASTM E662 Standard Test Method for Specific Optical Density of Smoke Generated by Solid Materials..7 ASTM E1643 Standard Practice for Selection, Design, Installation, and Inspection of Water Vapor Retarders Used in Contact with Earth or Granular Fill Under Concrete Slabs..8 ASTM E1745 Standard Specification for Water Vapor Retarders Used in Contact with Soil or Granular Fill under Concrete Slabs..9 ASTM F710 Standard Practice for Preparing Concrete Floors to Receive Resilient Flooring..10 ASTM F925 Standard Test Method for Resistance to Chemicals of Resilient Flooring..11 ASTM F970 Standard Test Method for Static Load Limit..12 ASTM F1344 Standard Specification for Rubber Floor Tile (sections 7.1-7.6, 8.4-8.6)..13 ASTM F1514 Standard Test Method for Measuring Heat Stability of Resilient Flooring by Color Change..14 ASTM F1515 Standard Test Method for Measuring Light Stability of Resilient Flooring by Color Change.15 ASTM F1859 Standard Specification for Rubber Sheet Floor Covering without Backing (sections 7.1-7.6, 8.4-8.6)..16 ASTM F1869 Standard Test Method for Measuring Moisture Vapor Emission Rate of Concrete Subfloor Using Anhydrous Calcium Chloride..17 ASTM F2170 Standard Test Method for Determining Relative Humidity in Concrete Floor Slabs Using in situ Probes..18 ASTM G21 Standard Practice for Determining Resistance of Synthetic Polymeric Materials to Fungi..3 THE BLUE ANGEL:.1 RAL-UZ 120: Elastic Floor Coverings. German standard for eco-labeling. Blue Angel products meet a list of criteria considering environmental and health-related aspects..4 GERMAN INSTITUTE FOR STANDARDIZATION (DIN):.1 DIN 51130: Testing of floor coverings Determination of the anti-slip property..2 DIN 52612: Testing of thermal insulating materials Determination of thermal conductivity..5 EUROPEAN COMMITTEE FOR STANDARDIZATION (CEN):.1 EN 423: Resilient floor coverings. Determination of resistance to staining..2 EN 425: Resilient and laminate floor coverings. Castor chair test..3 EN 433: Resilient floor coverings. Determination of residual indentation after static loading..4 EN 434: Resilient floor coverings. Determination of dimensional stability and curling after exposure to heat..5 EN 435: Resilient floor coverings. Determination of flexibility..6 EN 1081: Resilient floor coverings. Determination of electrical resistance..7 EN 1815: Resilient and textile floor coverings. Assessment of static electrical propensity..8 EN 1817: Resilient floor coverings. Specification for homogeneous and heterogeneous smooth rubber floor coverings..9 EN 13501-1: Fire classification of construction products and building elements Part 1: Classification using data from reaction to fire tests..10 EN 13893: Resilient, laminate and textile floor coverings. Measurement of dynamic coefficient of friction on dry floor surfaces..6 GREENGUARD ENVIRONMENTAL INSTITUTE (GEI):.1 GREENGUARD Certification: Compliant with stringent emission levels for over 360 VOCs, plus a limit on the total of all chemical emissions combined (TVOC). R101713 Page 2 of 8

.2 GREENGUARD Gold: Compliant with safety factors to account for sensitive individuals (such as children and the elderly) and ensures that a product is acceptable for use in environments such as schools and healthcare facilities..7 INTERNATIONAL ORGANIZATION FOR STANDARDIZATION (ISO):.1 ISO 105-B02: Textiles. Tests for colour fastness - Part B02: Colour fastness to artificial light: Xenon arc fading lamp test..2 ISO 4649: Determination of abrasion resistance using a rotating cylindrical drum device..3 ISO 7619: Determination of indentation hardness Part 1: Durometer method (Shore hardness)..4 ISO 9001: Requirement for Quality Management Systems..5 ISO 10140-3: Acoustics. Laboratory measurement of sound insulation of building elements Part 3: Measurement of impact sound insulation..6 ISO 14001: Requirements with Guidance for Use for Environmental Management Systems. 1.4 SUBMITTALS SPECIFIER NOTE: The following are typical submittals. The Specifier may choose to include other submittals he/she deems necessary..1 Provide Manufacturer s current printed data sheets on specified products (flooring, adhesives, accessories, etc.)..2 Provide samples, 6 inches x 6 inches, for verification of such characteristics as color, texture and finish for each specified resilient flooring product..3 If heat welding of seams for sheet goods has been specified, provide samples of welding rod for verification of color match..4 As necessary, provide shop drawings prepared for project illustrating layouts, details, dimensions and other data. 1.5 INFORMATIONAL SUBMITTALS.1 Provide current subfloor preparation guidelines, as published by the Manufacturer..2 Provide current installation guidelines, as published by the Manufacturer..3 If heat welding of seams for sheet goods has been specified, provide current heat welding instructions, as published by the Manufacturer. 1.6 CLOSEOUT SUBMITTALS.1 Provide current maintenance guidelines, as published by the Manufacturer..2 Provide current standard warranty, as published by the Manufacturer. 1.7 MAINTENANCE MATERIAL SUBMITTALS.1 Provide extra stock materials for use in facility operation and maintenance. Provide amount of approximately 2% of the total floor surface, of each type, color and dye lot. 1.8 QUALITY ASSURANCE.1 Manufacturer must be certified ISO 9001 and ISO 14001..2 Manufacturer must have a minimum of fifteen (15) years of experience in the manufacturing of prefabricated resilient commercial flooring..3 Installer must have performed installations of the same scale in the last three (3) years..4 Installer to be recognized and approved by the resilient flooring Manufacturer. R101713 Page 3 of 8

SPECIFIER NOTE: Specify mock-up dimensions as instructed by Owner or Architect..5 Installation of mock-up is highly recommended and must be deemed acceptable by Owner and Architect. Mock-up is to be installed following the same procedures and utilizing the same specified materials that will be used for the actual project. 1.9 DELIVERY, STORAGE AND HANDLING - Mock-up size: [XX x XX (XX cm x XX cm)]..1 Materials must be delivered in Manufacturer s original, unopened and undamaged containers with identification labels intact..2 Store resilient sheet goods upright on a clean, dry, flat surface protected from all possible damage and from exposure to harmful weather conditions. Store resilient tiles on a clean, dry, flat surface, carefully protecting corners and edges from all possible damage and from exposure to harmful weather conditions..3 Recommended environmental condition for storage is a minimum of 55 o F (13 o C)..4 Material need not suffer damage during handling (i.e. edge chipping, excessive warping, etc.). 1.10 SITE CONDITIONS.1 The General Contractor or Construction Manager shall be responsible for ensuring all site conditions meet the requirements of the resilient flooring Manufacturer, as referenced herein at sections 3.2 and 3.3..2 Concrete subfloors on or below grade must be installed over a permanent effective vapor retarder, as per current versions of ASTM E1643 and ASTM E1745. The vapor retarder must be placed directly underneath the concrete slab, above the granular fill, as per Manufacturer s instructions. The vapor retarder must have a perm rating of 0.1 or less and must have a minimum thickness of 10 mils..3 No concrete sealers or curing compounds are applied to or mixed into the concrete (refer to Section 03 05 00 Common Work Results for Concrete of Division 3)..4 Installation to be carried out no sooner than the specified curing time of concrete subfloor (normal density concrete curing time is approximately 28 days for development of design strength). Refer to current version of ASTM F710..5 The subfloor surface must be free of any paint, wax, oil, grease, sealer, curing compound, solvent or any other contaminants that may inhibit bond. All contaminants must be removed from the surface via mechanical abatement..6 Smooth, dense finish, highly compacted with a tolerance of 1/8" in a 10 ft radius (3.2 mm in 3.05 m radius). Floor Flatness (FF) and Floor Levelness (FL) numbers are not recognized..7 Moisture and alkalinity tests must be performed on all concrete substrates, under in-service conditions. It is recommended to turn on the HVAC unit prior to performing moisture testing, in order to ensure stable testing conditions and accurate results. The concrete s surface ph should be between 7 and 10. Relative humidity of the concrete slab must not exceed the tolerance of the adhesive specified, in accordance with ASTM F2170 (in situ probes). Moisture vapor emissions from the concrete slab must not exceed the tolerance of the adhesive specified, in accordance with ASTM F1869 (anhydrous calcium chloride)..8 If installing over wood subfloors, Mondo recommends exterior grade plywood with at least one good side, such as: APA (Engineered Wood Association) Exterior grade plywood (A-A Exterior, A-B Exterior or A-C Exterior) and CANPLY (Canadian Plywood Association) Exterior certified plywood (Canada: Grade G2S A-A or G1S A-C. USA: G2S A-A, A-B, B-B, or G1S A-C, B-C). There must be proper underfloor ventilation, plywood must be dry and should have a moisture content ranging between 6 and 12%, when measured with a quality wood moisture meter (electronic hygrometer)..9 Maintain a stable room and subfloor temperature within the recommended range of 65 o F to 86 o F (18 o C to 30 o C), 48 hours prior to installation, during the installation, and 48 hours after the installation. Recommended ambient humidity control level is between 35% and 55%..10 Installation of resilient flooring will not commence unless all other trades in the building are completed. It is the General Contractor or Construction Manager s responsibility to maintain a secure and clean working area before, during and after the installation of the resilient flooring. R101713 Page 4 of 8

1.11 WARRANTY.1 Provide Manufacturer s current standard warranty..2 The resilient flooring is warranted to be free from manufacturing defects for a period of one (1) year from the date of shipment from the Manufacturer..3 The resilient flooring is warranted against excessive wear under normal usage for a period of ten (10) years from the date installation. 2 Products 2.1 MANUFACTURER.1 MONDO S.p.A.: Artigo S.p.A., 17014 Cairo Montenotte (SV), Loc. Carpeneto Italy. 2.2 MATERIALS SPECIFIER NOTE: Specify format and color of product used in project..1 HARMONI is prefabricated resilient rubber commercial flooring, calendered and vulcanized with a base of synthetic rubbers, stabilizing agents and pigmentation, as manufactured by Artigo S.p.A. or approved equal..2 Thicknesses: 0.118" (3mm)..3 Vulcanized dual durometer construction: the shore hardness of the top layer (wear layer) will be greater than that of the bottom layer. Shore hardness of layers to be recommended by the Manufacturer and to respect limits specified..4 Colors: Provided in standard, solid background colors with randomly colored chips throughout the wear layer s entire depth..5 Surface texture: Smooth..6 Finish: Factory applied low-gloss finish, cured by ultraviolet (UV) processing..7 Formats available: Sheet goods are 6'2" (1.90m) wide and 32'8" (10m) long. Tiles are 24" x 24" (61cm x 61cm). 2.3 PERFORMANCE.1 Product tested in accordance to ASTM F1859 for rubber sheet floor and ASTM F1344 for rubber floor tile..2 Product tested in accordance to EN 1817 for smooth rubber floor coverings..3 Performance of the resilient flooring to conform to the following criteria: Performance Criteria Test Method Result VOC Emissions AgBB Compliant Modulus at 10% elongation ASTM D412 300 psi Coefficient of Friction ASTM D2047 0.60 Hardness Shore A ASTM D2240 85 Taber Abrasion (H18 wheel, 1000g, 1000 cycles) ASTM D3389 <0.4g loss Critical Radiant Flux ASTM E648 0.45 W/cm 2, Class I Optical Density of Smoke ASTM E662 <450 Chemical Resistance ASTM F925 Compliant Static Loading ASTM F970 <0.005 in. (tested at 800lbs) Resistance to Heat ASTM F1514 Compliant Color Light Stability ASTM F1515 Compliant R101713 Page 5 of 8

Performance Criteria Test Method Result Fungal Resistance Test ASTM G21 No growth Anti-Slip Characteristics DIN 51130 6 (R9) Thermal Resistance DIN 52612 0.020 m 2 K/W Effects of Stains EN 423 Resistant (based on concentrations) Effect of Castor Chairs EN 425 Suitable with wheels type W. Residual Indentation (after static loading) EN 433 0.08mm Dimensional Stability EN 434 ±0.30% Flexibility (Method A) EN 435 No fissuring Electrical Resistance EN 1081 >10 10 ohm Electrostatic Charge EN 1815 2 kv (antistatic) Fire Classification EN 13501-1 Class B fl s1 Dynamic Coefficient of Friction EN 13893 0.30 (DS) Colour Fastness to Artificial Light (Method 3) ISO 105-B02 6 degree blue scale Abrasion Resistance (Method A) ISO 4649 160mm 3 Hardness (Shore A) ISO 7619 90 ± 5 Impact Sound Insulation ISO 10140-3 10db Environment and Health, Blue Angel RAL-UZ 120 Certified GREENGUARD Certification Yes GREENGUARD Gold Yes 2.4 ACCESSORY PRODUCTS SPECIFIER NOTE: Specify adhesive suitable for application and intended use, as well as all accessories required for the project..1 Provide suitable adhesive certified by the Manufacturer: MP 965 acrylic adhesive, PU 105 polyurethane adhesive or EP 55 epoxy adhesive. Refer to instruction manual of adhesives provided by resilient flooring Manufacturer for suitability..2 Patching or leveling compound to be supplied and/or recommended/approved by resilient flooring Manufacturer..3 If heat welding of seams for sheet goods has been specified, heat welding rod to be supplied and/or recommended/approved by resilient flooring Manufacturer. 3 Execution 3.1 INSTALLERS.1 Refer to section 1.8 of this document for requirements for installers. 3.2 EXAMINATION SPECIFIER NOTE: The following must be ensured prior to installation of resilient flooring. R101713 Page 6 of 8

.1 Ensure that concrete subfloors on or below grade are installed over a permanent effective vapor retarder, as per current versions of ASTM E1643 and ASTM E1745. The vapor retarder must be placed directly underneath the concrete slab, above the granular fill, as per Manufacturer s instructions. The vapor retarder must have a perm rating of 0.1 or less and must have a minimum thickness of 10 mils..2 Installation to be carried out no sooner than the specified curing time of concrete subfloor (normal density concrete curing time is approximately 28 days for development of design strength). Refer to current version of ASTM F710..3 Ensure that no concrete sealers or curing compounds have been applied to or mixed into the concrete (refer to Section 03 05 00 Common Work Results for Concrete of Division 3)..4 The subfloor surface must be free of any paint, wax, oil, grease, sealer, curing compound, solvent or any other contaminants that may inhibit bond. All contaminants must be removed from the surface via mechanical abatement..5 Smooth, dense finish, highly compacted with a tolerance of 1/8" in a 10 ft radius (3.2 mm in 3.05 m radius). Floor Flatness (FF) and Floor Levelness (FL) numbers are not recognized..6 Moisture and alkalinity tests must be performed on all concrete substrates, under in-service conditions. It is recommended to turn on the HVAC unit prior to performing moisture testing, in order to ensure stable testing conditions and accurate results. The concrete s surface ph should be between 7 and 10. Relative humidity of the concrete slab must not exceed the tolerance of the adhesive specified, in accordance with ASTM F2170 (in situ probes). Moisture vapor emissions from the concrete slab must not exceed the tolerance of the adhesive specified, in accordance with ASTM F1869 (anhydrous calcium chloride)..7 If installing over wood subfloors, Mondo recommends exterior grade plywood with at least one good side, such as: APA (Engineered Wood Association) Exterior grade plywood (A-A Exterior, A-B Exterior or A-C Exterior) and CANPLY (Canadian Plywood Association) Exterior certified plywood (Canada: Grade G2S A-A or G1S A-C. USA: G2S A-A, A-B, B-B, or G1S A-C, B-C). There must be proper underfloor ventilation, plywood must be dry and should have a moisture content ranging between 6 and 12%, when measured with a quality wood moisture meter (electronic hygrometer)..8 Maintain a stable room and subfloor temperature within the recommended range of 65 o F to 86 o F (18 o C to 30 o C), 48 hours prior to installation, during the installation, and 48 hours after the installation. Recommended ambient humidity control level is between 35% and 55%..9 Installation of resilient flooring will not commence unless all other trades in the building are completed. 3.3 SUBFLOOR PREPARATION SPECIFIER NOTE: Subfloors are to be prepared according to resilient flooring Manufacturer s written instructions; it is recommended that the Specifier review all recommendations. A copy of the current Subfloor Preparation Guide can be obtained from the Technical Department at Mondo America, Inc. The following are considered common practice subfloor preparations to receive resilient flooring, and as such should not be omitted or altered in any case..1 Prepare concrete subfloor in accordance with Manufacturer s current printed Subfloor Preparation Guide. 3.4 INSTALLATION SPECIFIER NOTE: Resilient flooring products are to be installed according to resilient flooring Manufacturer s written instructions; it is recommended that the Specifier review all recommendations. A copy of the current Commercial Installation procedures can be obtained from the Technical Department at Mondo America, Inc. The following procedures may be altered to accommodate special project cases, as deemed necessary by the Specifier and after he/she has consulted the Technical Department at Mondo America, Inc. to ensure suitability..1 Install resilient sheet goods in accordance with Manufacturer s current printed Installation Manual..2 If heat welding of seams for sheet goods has been specified, weld seams in accordance with Manufacturer s current heat welding instructions..3 Install resilient tiles in accordance with Manufacturer s current printed Installation Manual. R101713 Page 7 of 8

3.5 REPAIR.1 Refer to section 1.7 for extra stock materials..2 Repair flooring using same dye lot as original materials supplied for the initial installation..3 Repairs are to be performed by qualified installers/technicians only. 3.6 CLEANING.1 Initial cleaning should not be performed until a minimum of 72 hours after the complete installation of the resilient flooring..2 Maintain resilient flooring according to Manufacturer s current maintenance instructions for specified product. 3.7 PROTECTION.1 As needed, resilient flooring can be protected with 1/8 Masonite during and after the installation, prior to acceptance by the Owner. R101713 Page 8 of 8