Federal and State Residential Garage Door Operator Legislation Guidelines For Dealers and Installers

Similar documents
Rationale Behind the Provisions of ASTM F 2200 & Illustration Guidelines Based on the Provisions of ASTM F 2200

#267. Rolling Door Labels

LOCAL LAW 88: LIGHTING UPGRADES AND SUB-METERING Version 1: May 2015

RISK CONTROL SOLUTIONS

Form I-9 completion guide

Rationale Behind the Provisions of ASTM F 2200 & Illustration Guidelines Based on the Provisions of ASTM F 2200

Rationale Behind the Provisions of ASTM F 2200 & Illustration Guidelines Based on the Provisions of ASTM F 2200

2015 HOLLAND FARMERS MARKET RULES & REGULATIONS

NEW HIRE REPORTING INFORMATION FOR MINNESOTA

Guide Specification for High Performance Doors

Manual Rotary Heat Sealers. Type: F108TX. List of content : Introduction 2. General description 3. Application 4. Safety precautions 5

SECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how?

NEW HIRE AND INDEPENDENT CONTRACTOR REPORTING INFORMATION FOR CONNECTICUT

EMPLOYMENT DISCRIMINATION CHARGE QUESTIONNAIRE

NEW HIRE REPORTING INFORMATION FOR NORTH CAROLINA

SECTION SECTIONAL OVERHEAD DOORS 416 SERIES SECTIONAL STEEL DOORS

SECTION SECTIONAL OVERHEAD DOORS 424 SERIES SECTIONAL STEEL DOORS

Lockout/Tagout Program (Control of Hazardous Energy)

NEW HIRE REPORTING INFORMATION FOR NEBRASKA

NEW HIRE REPORTING INFORMATION FOR VIRGINIA

IMPORTANT NOTICE- RESPONSE REQUESTED 2014 California Proposition 65 Requirements for Wood Product Warnings to Consumers

DEPARTMENT OF PUBLIC UTILITIES

SECTION SECTIONAL OVERHEAD DOORS 418 SERIES INSULATED STEEL DOORS

SECTION SECTIONAL OVERHEAD DOORS 422 SERIES INSULATED STEEL DOORS

SECTION SECTIONAL OVERHEAD DOORS 432 SERIES INSULATED STEEL DOORS

SECTION SECTIONAL OVERHEAD DOORS 511 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

NEW HIRE REPORTING INFORMATION FOR INDIANA

Ontario Building Code Compliant Door Activation Switches

PROPOSITION 65 1 CLEAR AND REASONABLE WARNINGS QUESTIONS AND ANSWERS FOR BUSINESSES

INTRODUCTION Copyright

AMERICAN NATIONAL STANDARD. Door & Access Systems Manufacturers Association, International ANSI/DASMA

Series - 1

Consumer Rights Act 2015

NEW HIRE REPORTING INFORMATION FOR NORTH DAKOTA

WASTE LEGISLATION - THE COST OF NON-COMPLIANCE

DOES YOUR PRODUCT CONTAIN CHEMICALS THAT REQUIRE A WARNING?

Procedure: Fixed plant and equipment - machine guarding

California employers are burdened with more wage and hour gotchas than any other

Exempt vs. Non Exempt

UL ENVIRONMENT TECHNICAL BRIEF CARB FORMALDEHYDE RISKS

NEW HIRE REPORTING INFORMATION FOR MARYLAND

Operation and Safety Manual for Single Skin roller shutters supplied by Paramount 26 LTD,

Qualification of Suppliers of Safety Critical Engineering Products and Services

OPERATING POLICY MANUAL

Minnesota State Colleges and Universities. Prevailing Wage Payroll Collection Procedure Facilities Construction Contracts July 2009

2015 Top Ten List of Wage and Hour Violations in New Hampshire (and how to avoid them in 2016)

CITY OF LOS ANGELES RULES AND REGULATIONS IMPLEMENTING THE FAIR CHANCE INITIATIVE FOR HIRING (BAN THE BOX) ORDINANCE EFFECTIVE JANUARY 22, 2017

PERSONNEL ISSUES: DISCIPLINE AND TERMINATION

AUTOMATIC FOLDING DOOR

Poisonings from Housing. A Regulatory Update

LEGAL OBLIGATIONS OF NON- PROFIT BOARDS

Mourant Ozannes Jersey - Channel Islands

Title 10: COMMERCE AND TRADE

CHAPTER 4. Solid Waste Management

Useful Information for Crews

2200 LOCK-OUT TAG-OUT PROGRAM. Document History. Version Date Comments

LOWE S INSTALLER LRRP CHECKLIST FOR RENOVATIONS PERFORMED IN PRE-1978 HOUSING AND CHILD-OCCUPIED FACILITIES

ENGLISH Compact Half Coupler 50 mm, SWL: 50 kg

Innovative Marketing Ideas That Work

Operation and Maintenance Manual

EMPLOYEE SAFETY HANDBOOK

SECTION SECTIONAL OVERHEAD DOORS

TRUCK HOIST A TOP Safety Requirements Please Read!

California Grocers Association Proposition 65 New Clear and Reasonable Warning Regulation Webinar

ASSEMBLY, No STATE OF NEW JERSEY. 217th LEGISLATURE PRE-FILED FOR INTRODUCTION IN THE 2016 SESSION

EPA s Lead Program Rule At-A-Glance

RECRUITMENT & SELECTION POLICY

Consumer Products: The Latest on the CPSIA, Recalls and Product Testing Tuesday, September 28, 2010 Presented By the IADC Product Liability Committees

NEW HIRE REPORTING INFORMATION FOR KENTUCKY

ENVIRONMENTAL PROTECTION, COMPLIANCE AND REPORTING

Procedure. Procedure

Policy No Northwest Louisiana Technical College

2012 International Building Code Errata (Portions of text and tables not shown are unaffected by the errata)

U.S. OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 (HAZARD COMMUNICATION)

Sample Written Program. for. Control of Hazardous Energy (Lockout/Tagout) OSHCON

Instructions for the Use of the. SMB SOLAR MULTIBOARD (also referred to as SMB or board below) on Photovoltaic Arrays with Framed Modules

SECTION SECTIONAL OVERHEAD DOORS

Proposition 65 New 2018 Clear and Reasonable Warnings

NEW HIRE REPORTING INFORMATION FOR ILLINOIS

TEXAS DEPARTMENT OF TRANSPORTATION PROCUREMENT DIVISION PRESS, GYRATORY, ASPHALT, PORTABLE PUBLICATION

VISTA OWNER S MANUAL ATLAS. VISTA RESIDENTIAL & COMMERCIAL Rev: March 20, 2018 p/n:

1. Section Steel Doors and Frames. 2. Section Flush Wood Doors 3. Section Aluminum Storefront Doors.

COUNCIL ORDER No

KEEP FOR FUTURE REFERENCE FORKLIFT ADAPTER FOR MRTA6 AND MRTA8 LIFTERS READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT

Drag Chain Conveyor Installation and Operation Manual

New and Young Workers Blitz

HOUSE BILL No. UTILITY METER FREEDOM OF CHOICE AMENDMENT. A bill to amend Chapter 460 Michigan Public Act 3 of 1939, entitled

Kansas Pharmacy Act Amendments; Filling and Refilling Prescriptions; Biological Products; Senate Sub. for HB 2055

County College of Morris. Hazard Communication Program

Continuous Wave Single Frequency Lasers. SCHERZO Series. 532nm 300mW

NEW HIRE REPORTING INFORMATION FOR ARKANSAS

DOCK LEVELLER USER MANUAL

2. General Regulations 2.1 Application of Tariff

NEW HIRE REPORTING INFORMATION FOR MISSISSIPPI

NEW HIRE REPORTING INFORMATION FOR GEORGIA

LOCKOUT TAGOUT SAFETY PROGRAM

Emergency Preparedness Act (Estonia)

MEDICINES CONTROL COUNCIL

HAZARDOUS COMMUNICATION PROGRAM VERMILION COUNTY

Continuous Wave Single Frequency Lasers. SYMPHONY Series. 532nm 2000mW

Transcription:

Federal and State Residential Garage Door Operator Legislation Guidelines For Dealers and Installers Following are some questions asked by dealers and installers about federal and state laws related to residential garage door operators (GDO's). Many of these laws changed effective January 1, 1993, and affect the way you do business now and in the future. What Changed in 1993 Federal law required manufacturers of residential GDO's to change the way they make their products. Residential GDO's manufactured on and after January 1, 1993 must: 1. Have an automatic inherent reverse feature that reverses after 2 seconds upon sensing an obstruction; 2. Have a 30 second reverse timer that moves the door upward 30 seconds after sensing the door has not reached the fully closed position; 3. Have a secondary entrapment protection system, which may be either an attached and working external device (example: edge sensor or photoelectric eye) or an inherent secondary system (example: combination sectional door and operator system with the entire door system acting as a force sensing device); and 4. Close the door using the manufacturer's suggested devices (either a wall switch or a push button remote control). May I Continue to Purchase, Sell and Install Old Units? The federal law applies only to the manufacture of residential units beginning in 1993. It does not prohibit you from purchasing, selling or installing older GDO's; however, all dealers and installers are also affected by state and local laws and court rulings, which may include civil penalties for installations found to be non-compliant. Laws and rulings differ from state to state, some of which are briefly summarized below: 2/8/06; Rev. 01/14. Page 1 of 6This sheet is reviewed periodically and may be updated. Visit www.dasma.com for the latest version.

Minnesota and New York: On and after January 1, 1993, you may not sell, purchase or install a GDO for a single or multi-family residence in Minnesota or New York unless it complies with the new standards. California: Since January 1, 1991, you may not sell, purchase or install a GDO for a single or multifamily residence in California unless it complies with the new standards. In addition, since January 1, 1993, you may not sell, purchase or install a GDO for a single or multifamily residence in California unless, in order to operate, it requires the inclusion of a tactile garage door edge sensor, an optical sensor, or a similar device that when activated is designed to cause the closing door to open and prevent an open door from closing. Under the California statute, a GDO manufactured prior to January 1, 1993, and that was in the possession of a retailer or wholesaler on January 1, 1993, may have been purchased, sold, offered for sale, and installed on or before July 1, 1993, provided the GDO was in compliance with the new standards in effect as of January 1, 1993. Indiana: You may not install a GDO for a residence in Indiana unless it has the automatic reverse feature and 30-second reverse timer. This requirement took effect January 1, 1993. All Other States: No other states have specific installation requirements, but your city or county may. Check with your attorney. In addition to any specific GDO laws, each state has general product liability laws and court rulings that may affect your decision on what to install. You should note that DASMA does not support the installation of non-compliant or "old" products, even if there is no state regulation outlawing such products. Supporting this assertion is the knowledge that compliance to the new regulations reduces injuries. How do I know if a GDO complies with the New Standard For residential units manufactured before January 1, 1993, consult your distributor or manufacturer to find out how to identify the new units. For residential units manufactured after January 1, 1993, look for the following: a. a label showing a manufacture date on or after Jan. 1, 1993 and the listing agency logo; or b. a label showing a manufacture date on or after Jan. 1, 1993 and stating that the unit is manufactured in accordance with UL 325 or federal standards. Different manufacturers will use different labels. When in doubt, check with your distributor or manufacturer. 2/8/06; Rev. 01/14. Page 2 of 6This sheet is reviewed periodically and may be updated. Visit www.dasma.com for the latest version.

Am I Permitted To Repair Existing GDO's That Do Not Comply With The New Requirements #351 Currently, there are no federal laws that prohibit repair of non-compliant existing GDO's. You should check your state and local laws that may govern this issue. DASMA does not support the installation of non-compliant or "old" products, even if there is no state regulation outlawing such products. Supporting this assertion is the knowledge that compliance to the new regulations reduces injuries. You should advise the owner of the non-compliant GDO and ask the owner to consider replacing the existing GDO with one that meets the current safety requirements. You should mark in writing on the owner's work order the status of the existing GDO with respect to the new requirements and whether or not the owner decided to replace the GDO. The owner should sign the work order acknowledging the above. When Should I Test the Automatic Reverse Feature? Always test the GDO's automatic reverse feature whenever you install, service, or repair any GDO, garage door, or any hardware or remote controls. The testing and tagging procedure recommended by DASMA is described in the attached statement. This is for the customer's protection, and yours. Testing and tagging are mandatory under California, New York, Minnesota and Indiana state laws. These laws are briefly described below; however, even if you are not in one of those states, you should always test the operator. California: When you are hired to service or repair a residential GDO (or to replace a garage door), you must test the operator for reversal on a 2-inch block (a wood 2x4 laid flat is acceptable) on the floor in the center of the door. If the door does not reverse when it strikes the block (or 2x4), it does not meet the test. You must place a red warning tag on the unit. There is a specific form for the tag - ask your trade association or check the law for the required form. Indiana: When you are hired to service or repair a residential GDO, you must test the operator for reversal on a 2-inch block (a wood 2x4 laid flat is acceptable) on the floor in the center of the door. If the door does not reverse when it strikes the block (or 2x4), it does not meet the test. You must place an orange warning tag on the unit. There is specific information that must be on the tag, including the word "WARNING" in black on an orange background - ask your trade association or check the law for the required form. You must notify the occupant in writing within 10 working days that the unit is not in compliance. This law came into effect January 1, 1994. Minnesota: When you are asked to service or repair a residential GDO, you must first test it to make sure it reverses on a 1-inch block within 2 seconds. If it does not, you may not service or 2/8/06; Rev. 01/14. Page 3 of 6This sheet is reviewed periodically and may be updated. Visit www.dasma.com for the latest version.

repair. You must attach a red tag to units that do not pass this test - ask your trade association or check the law for the required form. You must also notify the occupant in writing within 10 working days that the unit is not in compliance. New York: When you are asked to service or repair a residential GDO, you must first test it to make sure it reverses on a 1-inch block within 2 seconds. If it does not, you may not service or repair. You must attach a red label to units that do not pass this test - ask your trade association or check law for the required form. You must also notify the occupant in writing within 10 working days that the unit is not in compliance. Please note that the materials given to the customer often recommend that the customer test by using a wood 2 x 4 laid flat; however, in New York and Minnesota, different test procedures apply to the installer or service personnel. Do I Need to Leave Any Materials with the Customer You should always leave a full set of the manufacturer's written materials with the customer when you install any GDO. California law specifically requires this, and DASMA recommends that dealers and installers in all states follow this practice. Even on a service call, ask customers if they have the owner's manual. If not, advise them to get a copy from the manufacturer. You should also put up any wall labels and use safety brochures provided by the manufacturer with the product. These help remind the customer of the risk of entrapment and the need to regularly test the door. Extra wall labels and brochures may be obtained from DASMA or the International Door Association (IDA). You should use the pamphlet and wall label as an opportunity to educate the customer on the proper use, maintenance and testing of the GDO. This is for customer's protection, and yours. Customers can get a free safety brochure by calling 1-800-276-3919 or by accessing the brochure at www.dasma.com. If you do not have a supply, you should suggest that the customer call or access the web for this free information. What Do I Do about Commercial and Industrial Operators? When installing commercial or industrial door operators, the safety devices used should be appropriate for the application. Commercial or industrial operators can never be installed in a single family residence without first complying with regulations of UL 325 regarding residential operators. If a residential installation requires commercial/industrial duty equipment, consult the operator manufacturer for operators suitable for both residential and commercial/industrial needs. When servicing commercial/industrial operating systems, test all safety devices and document the results of the test, just 2/8/06; Rev. 01/14. Page 4 of 6This sheet is reviewed periodically and may be updated. Visit www.dasma.com for the latest version.

as you would with a residential unit. California, New York, Indiana and Minnesota have laws that include specific requirements for operators. If you work in one of those states, check with your attorney. THIS IS A BRIEF SUMMARY FOR YOUR REFERENCE. IT IS NOT DETAILED OR COMPLETE, AND DOES NOT CONSTITUTE LEGAL ADVICE. CONSULT WITH YOUR ATTORNEY FOR MORE DETAILS. 2/8/06; Rev. 01/14. Page 5 of 6This sheet is reviewed periodically and may be updated. Visit www.dasma.com for the latest version.

STATEMENT OF TESTING FOR AUTOMATIC REVERSE FEATURES OF GARAGE DOOR OPERATORS The Door & Access Systems Manufacturers Association (DASMA) has prepared the following statements for dealers regarding the testing of automatic reverse features for garage door operators upon each installations, service or repair: 1. Garage doors and garage door operators should be installed, maintained, tested and operated in accordance with the instructions contained in the owner's manual. 2. All instructions included by the manufacturer with the operator must be left with the customer upon completion of any installation. A receipt should be obtained for your records. 3. All garage door operators manufactured on or after January 1, 1991 must be in compliance with the automatic reverse requirements for garage door operators, as published by Underwriter's Laboratories in UL 325. All garage door operators manufactured on or after January 1, 1993 must be in compliance with the secondary entrapment device requirements (such as the use of photoelectric sensors or edge sensors) for garage door operators, as published by Underwriters Laboratories in UL 325. To make sure the operator you are installing is in compliance, look for the UL listing mark, or other listing mark or statement that indicates the operator is in compliance with the UL 325 reversing requirements. 4. Each time you are called upon to install or service a garage door operator, garage door, or related components, you should always test the garage door operator to ensure that it automatically reverses off of a 1 inch or 2 inch block (see manufacturer's instructions) placed flat under the center of the door. You should document that the test was performed, and retain the document in your permanent records. The customer should be advised to repeat this test every month. 5. If a garage door operator cannot be adjusted to reverse on a 1 inch or 2 inch obstruction as described above, the customer should be advised verbally and in writing that the operator as tested on site does not comply with the current federal standard for new operators and that the garage door operator (or, if necessary to make the operator work correctly, the door or related components) should be repaired or replaced. You should document this advice, obtain a receipt from the customer showing the customer received the advice and the document, and retain the document in your permanent records. THESE GENERAL GUIDELINES ARE FOR YOUR ASSISTANCE IN EDUCATING CUSTOMERS AND TESTING OPERATORS FOR AUTOMATIC REVERSE FEATURES. THEY DO NOT PURPORT TO BE EXHAUSTIVE OR COMPLETE, OR TO BE A SUBSTITUTE FOR DOOR INSTALLATION AND REPAIR PRACTICES. THE RECOMMENDED TEST DOES NOT PURPORT TO ENSURE COMPLETE COMPLIANCE WITH UL STANDARDS - THAT CAN ONLY BE DONE IN A LABORATORY. STATE, AND LOCAL LAWS MAY CONTAIN ADDITIONAL OR DIFFERENT REQUIREMENTS, SO PLEASE CONSULT YOUR ATTORNEY. If you have any questions concerning these guidelines, please contact the manufacturer of the garage door operator. For further information, you may contact DASMA at (216) 241-7333 or via e-mail at dasma@dasma.com. 2/8/06; Rev. 01/14. Page 6 of 6This sheet is reviewed periodically and may be updated. Visit www.dasma.com for the latest version.