SECTION CHAIN-LINK FENCES AND GATES 02821/1

Similar documents
A. Product Data shall be provided for each type of product indicated.

Houston Community College 3200 Main Parking Garage November 15, 2010 Houston Community College

SECTION CHAIN LINK FENCING

SECTION CHAIN LINK FENCES AND GATES (PARK)

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

1. Fence and gate posts, rails, and fittings. 2. Chain-link fabric, reinforcements, and attachments.

SECTION CHAIN LINK FENCES

SECTION HIGH-SECURITY CHAIN LINK FENCES AND GATES

Bus Facility

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DISTRIBUTION EQUIPMENT

SECTION CHAIN LINK FENCES AND GATES

ITEM 555 CHAIN LINK FENCING

SECTION CHAIN LINK FENCES AND GATES (GALVANIZED) A. Fence framework, fabric, gates, and accessories.

CITY OF MOUNT DORA LIFT STATION CHAINLINK FENCE AND GATE SPECIFICATIONS

LS3P ASSOCIATES LTD. FCCC CHASSIS SHIPPING FACILITY

MO: Tl RSA: 1406B

SECTION 2831 ITEM F-162 CHAIN-LINK FENCES

MERCHANTS METALS. A. ASTM F552 Standard Terminology Relating to Chain Link Fencing

Colorado River Aqueduct Pumping Plants 230 kv Disconnect Switches Replacement

SECTION CHAIN LINK FENCES AND GATES

Copyright 2002 and 2005 AIA MASTERSPEC Full Length 08/02 (R 02/06)

TITLE: CAMP JOHNSON OVERPASS / HWY 17 BYPASS SECURITY FENCE UPGRADES

ANTI RAM SECURITY CHAIN LINK FENCE - 4, MPH SECTION

Bear Exhibit Fence Upgrades. The following modifications are hereby made part of the contract documents:

CHAIN LINK FENCES AND GATES

A. ASTM A121 Specification for Metallic-Coated Carbon Steel Barbed Wire. B. ASTM A392 Specification for Zinc-Coated Steel Chain-Link Fence Fabric

SECTION ORNAMENTAL WELDED STEEL FENCING

CITY OF FRIENDSWOOD TECHNICAL SPECIFICATIONS DOCUMENT 00085B ADDENDUM ADDENDUM NO. 1

LOCATION MAP Salzedo Street, Third Floor Coral Gables, FL (305)

SECTION CHAIN LINK FENCES AND GATES

SECTION CHAIN LINK FENCING

CHAIN LINK FENCES AND GATES

SECTION ORNAMENTAL ALUMINUM FENCING

CW 3550 Chain Link and Drift Control Fence TABLE OF CONTENTS

SECTION CHAIN LINK FENCES AND GATES

UNIFIED FACILITIES GUIDE SPECIFICATIONS

A NEW PRE-K BUILDING FOR BIG SPRING LAKE KINDERGARTEN SCHOOL FOR THE ALBERTVILLE CITY BOARD OF EDUCATION ALBERTVILLE, ALABAMA

Advisory Circular PAGECONTROLCHART. Remove Pages Dated II Inscr t Pages Dated l/2/ thru 258-l 7/6/ l/2/90

SECTION 1043 FENCE MATERIAL

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION CHAIN LINK FENCING

Fence SpecCheck. A53/A53M-12 Schedule 40 & Schedule 80 Pipe: Specification for Pipe, Steel, Black

1. Include plans, elevations, sections, details, and attachments to other work.

CONSTRUCTION SPECIFICATION FOR CHAIN-LINK FENCE

PROPOSAL FOR WROUGHT IRON PERIMETER FENCE WITH GATE TO CITY OF POMONA

Special Provision No. 541S01 October OPSS 541, Construction Specifications for Chain Link Fence, is deleted and replaced with the following:

SECTION METAL STAIRS

CONSTRUCTION SPECIFICATION FOR CHAIN LINK FENCE

SECTION 410 FENCES All materials shall be new and without flaws or defects of any type GENERAL

SECTION GROUNDING AND BONDING

SECTION SECURITY GRILLES 670 SERIES UPCOILING SECURITY GRILLE

TWINBAR FENCE SYSTEM ENTER PROJECT NAME HERE 12/2011

SECTION ACCORDION FOLDING PARTITIONS

SECTION 1208 CHAIN LINK FENCING DESCRIPTION

SECTION METAL STAIRS

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, EDITION 2007

SECTION GROUNDING AND BONDING

CONSTRUCTION SPECIFICATION FOR CHAIN-LINK FENCE

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

SECTION OVERHEAD COILING FIRE DOORS MODEL 662 OVERHEAD COILING COUNTER FIRE DOORS WITH INTEGRAL FRAME

SECTION ALUMINUM HANDRAIL SYSTEMS

MATERIAL SPECIFICATION FOR CHAIN-LINK FENCE COMPONENTS

SECTION GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS

LRGVDC Rio Transit Center Renovation & Expansion

AMEGO FENCE SYSTEM ENTER PROJECT NAME HERE 12/2011

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

.1 American Institute of Steel Construction (AISC) Specifications for Steel Buildings AISC

SECTION HANGERS AND SUPPORTS FOR PLUMBING

SECTION DECORATIVE METAL RAILINGS

SECTION SECURITY GRILLES 679 SERIES SUPERGARD SIDE FOLDING GRILLE

Essex County College - West Essex Campus Addition And Renovations dlb # / SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

CONSTRUCTION SPECIFICATION FOR CHAIN-LINK FENCE

SECTION SECTIONAL OVERHEAD DOORS

NORTHWESTERN UNIVERSITY PROJECT NAME JOB #

SECTION FENCING. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

SECTION METAL ATHLETIC LOCKERS

A. Coordinate chain link fence & gate work with work before and after. See especially: 1. Bollards on worksite that are more than 10 ft from fence.

Aluminum Perforated Rolling Door

Preassembled steel stairs with concrete-filled treads.

TRANSPORT LINK CHAIN LINK CANTILEVER GATES

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SECTION SECTIONAL OVERHEAD DOORS

SECTION MISCELLANEOUS METALS

SECTION (16071) - VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

Invitation to Bid MHM

Student Services & Classroom Addition

1. Seismic Loads: Reference structural drawings.

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011.

Metropolitan Parks of Tacoma Addendum #01 Waterfront Phase 1 GC/CM Guy F. Atkinson Construction Page 1 of 1

SECTION ROOF ACCESSORIES

SECTION DETENTION WINDOW SCREENS. 1. Detention screens for interior and exterior installations at exterior windows in existing buildings.

SECTION GROUNDING AND BONDING FOR ELECTRONIC SAFETY AND SECURITY

SECTION ELECTRIC FOUR FOLD DOORS MODEL 46 FLAT SHEETED

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SUPPORT AND ANCHORS SECTION 15090

SECTION ORNAMENTAL ALUMINUM RAILING

1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases.

.1 ANSI/ASME B31.1, Power Piping, (SI Edition)..2 American Society for Testing and Materials (ASTM)

SECTION METAL ATHLETIC LOCKERS

1. Vertical reciprocating conveyor, Hydraulic straddle VRC.

Transcription:

SECTION 02821 - CHAIN-LINK FENCES AND GATES 02821/1 PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Chain-Link Fences: 2. Gates: horizontal slide or swing. 3. Fences installed where indicated on plans with Evergreen Hedge shrub-like chain link filler. B. See Division 16 Sections for electrical service and connections for motor operators, controls, limit and disconnect switches, and safety features and for system disconnect switches. 1.2 REFERENCES A. Chain Link Fence Manufacturers Institute (CLFMI) Voluntary Standard for Chain Link Fence Installation. B. ASTM F1083 Black and Hot Dip Zinc Coated (Galvanized) Welded and seamless steel pipe. C. ASTM A123 Zinc (Hot Galvanized Coatings on Products Fabricated from Rolled, Pressed and Forged Steel Shapes, Bars and Strips). D. ASTM A392 Class 1 E. Fittings ASTM F626 Fencing, Wire and Post Metal (chain-link fence fabric). 1.3 SUBMITTALS A. Product Data: For each type of product indicated. B. Shop Drawings: Show locations, components, materials, dimensions, sizes, weights, and finishes of components. Include plans, gate elevations, sections, details of post anchorage, attachment, bracing, and other required installation and operational clearances. 1. Gate Operator: Show locations and details for installing operator components, switches, and controls. Indicate motor size, electrical characteristics, drive arrangement, mounting, and grounding provisions. 1.4 QUALITY ASSURANCE A. Electrical Components, Devices, and Accessories: Listed and labeled as defined in NFPA 70, Article 100, by a testing agency acceptable to authorities having jurisdiction, and marked for intended use. B. UL Standard: Provide gate operators that comply with UL 325.

SECTION 02821 - CHAIN-LINK FENCES AND GATES 02821/2 C. Emergency Access Requirements: Comply with requirements of authorities having jurisdiction for automatic gate operators serving as a required means of access. PART 2 - PRODUCTS 2.1 CHAIN-LINK FENCE FABRIC A. General: Height indicated on Drawings. Comply with ASTM A 392, CLFMI CLF 2445, and requirements indicated below: 1. Steel Wire Fabric: Metallic-coated wire with a diameter of 0.148 inch. a. Mesh Size: 2 inches. 2.2 INDUSTRIAL FENCE FRAMING A. Posts and Rails: Comply with ASTM F 1043 for framing, ASTM F 1083 for Group IC round pipe, and the following: 1. Refer to plans for installation of galvanized steel or aluminum. 2. Group: IA: round steel pipe, Schedule 40. 3. Fence Height: 6 feet. (unless noted otherwise) 4. Strength Requirement: industrial according to ASTM F 1043. 5. Horizontal-Slide Gate Post: According to ASTM F 1184. 6. Coating for Steel Framing: a. Metallic coating. 2.3 TENSION WIRE A. General: Provide horizontal tension wire at bottom of fence fabric. B. Location: Extended along top of barbed wire arms extended posts and top of fence fabric for supporting barbed tape. C. Metallic-Coated Steel Wire: 0.177-inch- ASTM A 817 and ASTM A 824. diameter, marcelled tension wire complying with 1. Metallic Coating: Type III, Zn-5-Al-MM alloy.

SECTION 02821 - CHAIN-LINK FENCES AND GATES 02821/3 2.4 INDUSTRIAL SWING GATES A. General: Comply with ASTM F 900 for single and double swing gate types. 1. Metal Pipe and Tubing: Galvanized steel. Comply with ASTM F 1083 and ASTM F 1043 for materials and protective coatings. B. Frames and Bracing: Fabricate members from round, galvanized steel tubing with outside dimension and weight according to ASTM F 900 and the following: 1. Gate Fabric Height: 2 inches less than adjacent fence height or as indicated on plans. 2. Leaf Width: As indicated on plans. 3. Frame Members: a. Tubular Steel: 1.90 inches round. C. Frame Corner Construction: 1. assembled with corner fittings and 5/16-inch- diameter, adjustable truss rods for panels 5 feet wide or wider. D. Extended Gate Posts and Frame Members: Extend gate posts and frame end members above top of chain-link fabric at both ends of gate frame 12 inches as required to attach barbed wire assemblies. E. Hardware: Latches permitting operation from both sides of gate, hinges, provide center gate stops and keepers for each gate leaf more than 5 feet wide. Fabricate latches with integral eye openings for padlocking; padlock accessible from both sides of gate. 2.5 INDUSTRIAL HORIZONTAL-SLIDE GATES A. General: Comply with ASTM F 1184 for single and double slide gate types. 1. Classification: Type II Cantilever Slide, Class 1 with external roller assemblies. 2. Metal Pipe and Tubing: Galvanized steel. Comply with ASTM F 1184 for materials and protective coatings. B. Frames and Bracing: Fabricate members from round, galvanized steel tubing with outside dimension and weight according to ASTM F 1184 and the following: 1. Gate Fabric Height: 6 feet. 2. Gate Opening Width: As indicated on plans. 3. Frame Members and Bracing Members: Tubular steel. 1.90 inches round. C. Frame Corner Construction:

SECTION 02821 - CHAIN-LINK FENCES AND GATES 02821/4 1. Welded frame with panels assembled with bolted or riveted corner fittings and 5/16-inchdiameter, adjustable truss rods for panels 5 feet wide or wider. D. Extended Gate Posts and Frame Members: Extend gate posts and frame end members above top of chain-link fabric at both ends of gate frame 12 inches as required to attach barbed wire assemblies. E. Overhead Track Assembly: Manufacturer's standard track, with overhead framing supports, bracing, and accessories, engineered to support size, weight, width, operation, and design of gate and roller assemblies. F. Roller Guards: As required per ASTM F 1184 for Type II, Class 1 gates. G. Hardware: Latches permitting operation from both sides of gate, locking devices, hangers, roller assemblies and stops fabricated from galvanized steel. Fabricate latches with integral eye openings for padlocking; padlock accessible from both sides of gate. 2.6 FITTINGS A. General: Comply with ASTM F 626. B. Finish: 1. Metallic Coating for Pressed Steel or Cast Iron: Not less than 1.2 oz. /sq. ft. zinc. 2.7 BARBED WIRE A. Zinc-Coated Steel Barbed Wire: Comply with ASTM A 121; 2-point round barbs spaced not more than four (4) inches o.c. 2.8 GATE OPERATORS (where indicated on plans) A. General: Provide factory-assembled automatic operating system designed for gate size, type, weight, and operation frequency. Provide operation control system with characteristics suitable for Project conditions, with remote-control stations, safety devices, and weatherproof enclosures; coordinate electrical requirements with building electrical system. B. Comply with NFPA 70. C. Motor Characteristics: Sufficient to start, accelerate, and operate connected loads at designated speeds, within installed environment, with indicated operating sequence, and without exceeding nameplate rating or considering service factor. Comply with NEMA MG-1 and the following: 1. Voltage: Horsepower and phase NEMA standard voltage selected to operate on nominal circuit voltage to which motor is connected. and as recommended by manufacturer. CAST-IN-PLACE CONCRETE D. Materials: Portland cement complying with ASTM C 150, Type I aggregates complying with ASTM C 33, and potable water.

SECTION 02821 - CHAIN-LINK FENCES AND GATES 02821/5 1. Concrete Mixes: Normal-weight concrete with not less than 3000-psi compressive strength (28 days), three (3)-inch slump, and one (1)-inch maximum size aggregate. 2.9 FENCE GROUNDING A. Conductors: Bare, solid wire for No. 6 AWG and smaller; stranded wire for No. 4 AWG and larger. 1. Material on or below Finished Grade: Copper. 2. Bonding Jumpers: Braided copper tape, one (1) inch wide, woven of No. 30 AWG bare copper wire, terminated with copper ferrules. B. Connectors and Grounding Rods: Comply with UL 467. PART 3 - EXECUTION 3.1 INSTALLATION A. General: Install chain-link fencing to comply with ASTM F 567 and more stringent requirements specified. B. Post Excavation: Drill or hand-excavate holes for posts to diameters and spacings indicated, in firm, undisturbed soil. C. Post Setting: Set posts in concrete with mechanical anchors at indicated spacing into firm, undisturbed soil. 1. Concrete Fill: Place concrete around posts to dimensions indicated and vibrate or tamp for consolidation. Protect aboveground portion of posts from concrete splatter. D. Terminal Posts: Locate terminal end, corner, and gate posts per ASTM F 567 and terminal pull posts at changes in horizontal or vertical alignment. E. Line Posts: Space line posts uniformly at 10 feet o.c. F. Post Bracing and Intermediate Rails: Install according to ASTM F 567. Install braces at end and gate posts and at both sides of corner and pull posts. G. Tension Wire: Install according to ASTM F 567, maintaining plumb position and alignment of fencing. H. Top Rail: Install according to ASTM F 567. I. Bottom Rails: Install, spanning between posts. J. Chain-Link Fabric: Apply fabric to outside of enclosing framework. Leave two (2) inches between finish grade or surface and bottom selvage, unless otherwise indicated. K. Tie Wires: Attach wire per ASTM F 626. Bend ends of wire to minimize hazard to individuals and clothing.

SECTION 02821 - CHAIN-LINK FENCES AND GATES 02821/6 L. Fasteners: Install nuts for tension bands and carriage bolts on the side of the fence opposite the fabric side. M. Privacy Slats: Not Applied. N. Barbed Wire: Uniformly spaced. Pull wire taut and install securely to extension arms and secure to end post or terminal arms. 3.2 GATE INSTALLATION A. Install gates according to manufacturer's written instructions, level, plumb, and secure for full opening without interference. Attach fabric as for fencing. Attach hardware using tamperresistant or concealed means. Install ground-set items in concrete for anchorage. Adjust hardware for smooth operation and lubricate where necessary. 3.3 GATE OPERATOR INSTALLATION A. General: Install gate operators according to manufacturer's written instructions, aligned and true to fence line and grade. B. Concrete Bases/Pads: Cast-in-place or precast concrete, depth not less than 12 inches, dimensioned and reinforced according to gate-operator component manufacturer's written instructions and as indicated on Drawings. C. Comply with NFPA 70 and manufacturer's written instructions for grounding of electricpowered motors, controls, and other devices. 3.4 GROUNDING AND BONDING A. Fence Grounding: Install at maximum intervals of 1500 feet. B. Fences within 100 Feet of Buildings, Structures, Walkways, and Roadways: Ground at maximum intervals of 750 feet. 1. Grounding Method: At each grounding location, drive a grounding rod vertically until the top is six ( 6) inches below finished grade. Connect rod to fence with No. 6 AWG conductor. Connect conductor to each fence component at the grounding location. C. Bonding Method for Gates: Connect bonding jumper between gate post and gate frame. 1. Connections: Make connections so possibility of galvanic action or electrolysis is minimized. D. Bonding to Lightning Protection System: If fence terminates at lightning-protected building or structure, ground the fence and bond the fence grounding conductor to lightning protection down conductor or lightning protection grounding conductor complying with NFPA 780. END OF SECTION