PlusICE DAY NIGHT. Phase Change Material Passive Cooling Products PHASE CHANGE MATERIAL PRODUCTS LIMITED

Similar documents
12 th International Conference on Sustainable Energy technologies (SET-2013) 26-29th August, 2013 Hong Kong Paper ID: SET

Zafer URE.

12 th International Conference on Sustainable Energy technologies (SET-2013) 26-29th August, 2013 Hong Kong Paper ID: SET

ASHRAE 2004, ANAHEIM WINTER MEETING

Introduction to Geothermal Comfort Systems in INDIA

save save Advanced Phase Change Materials

GREENERGIZE your packaging

Phase Change Materials

Figure 1: Uncovered and covered PVT collectors

EXPERIENCES WITH LOWEX PCM CHILLED CEILINGS IN DEMONSTRATION BUILDINGS

CHAPTER 1 INTRODUCTION

THERMAL ENERGY STORAGE FOR SUPERMARKETS. Z. Ure CEng., MSc., MASHRAE, MCIBSE. M.InstR (1) C.B. Beggs BSc, MPhil, PhD, CEng, MCIBSE (2)

Green Data Center CRYOGEL Ice Ball Thermal Storage

Temperature regulation: Phase change materials (PCMs)

Although electricity is efficient at heating water it is expensive and not available everywhere.

The surface receives about 47% of the total solar energy that reaches the Earth. Only this amount is usable.

Available online at ScienceDirect. Energy Procedia 91 (2016 )

CEILING TILE. Thermal Mass. Passive Cooling. Thermal Comfort

The Impact of VISIONWALL High Performance Windows on the Northern Telecom Building in Ottawa, Ontario

Introduction to Geothermal Comfort Systems in INDIA

COOLZONE LIGHTWEIGHT THERMAL MASS FOR CLASSROOM COMFORT

Experimental Study to Evaluate the Performance of Iraqi Passive House in Summer Season

THE INSTITUTE OF REFRIGERATION

ARPAN JOHARI. Architect. 13/08/10 AW Design. Ahmedabad

PCM s in application for acclimatization of buildings. Nick Barnard, Faber Maunsell VSK2008, Workshop on heat storage

// Generator Hostel Amsterdam

REPORT ON THE BENEFITS OF ICE- BASED THERMAL STORAGE FOR DISTRICT COOLING IN THE UAE MARKETS

Chilled Water Plant Redesign

Welcome Everyone. Not Quite this kind! Geothermal Heat Pumps are a indirect solar heating system! Introduction to Geothermal

ICE THERMAL STORAGE AND LEED GOLD

PCM Plasterboard Knauf Comfortboard Phase change plasterboard thermal mass without the weight

Absorption Chillers in Industry

SorTech package solution description

B E Y O N D I N S U L AT I O N

Chapter 5 THE SECOND LAW OF THERMODYNAMICS

PHASE-CHANGE FRAME WALLS (PCFWS) FOR PEAK DEMAND REDUCTION, LOAD SHIFTING, ENERGY CONSERVATION, AND COMFORT

Passively-cooled shelters for remote equipment in hot and arid climates

ENRG Blanket goes to work immediately to save energy costs and reduce carbon emissions.

Eco ice systems mean you use innovative technology for cost-effective and environmentally friendly production of heat and cold.

DELTA -COOL 24. Phase Change Material Thermal Storage Mass for a Comfortable Interior Climate. PREMIUM QUALITY

IMPROVEMENT IN THERMEL STORAGE BY USING PCM AND NANO ADDICTIVE S

Digging Deeper SOLAR ENERGY. Forms of Solar Energy

Project Description. Projected build start date 15 Aug 2011 Projected date of occupation 19 Dec Existing external wall construction

Experimental Study on PCM-Air Heat Exchanger Used For Building Ventilation System

YORK PASSIVE CHILLED BEAMS ENGINEERING GUIDE

Geothermal Heating & Cooling in Health Care Applications

3C.1 Passive Solar Design National Sustainable Building Advisor Program

LITTLEPITS PASSIVHAUS PLUS

Energy-Efficient Passive House using thermal mass to achieve high thermal comfort

use Solar thermal for hot water production

PassiveDesign.org. Passive Construction. Name:...

St Loyes Extra Care Facility PHPP Pre-Assessment Report

use Solar thermal for hot water production DESIGN APPROACHES

Solutions for Office Buildings. E f f i c i e n t H e at i n g, C o o l i n g, a n d P l u m b i n g

Thermal Energy Storage Using Phase Change Material

Reducing The Carbon Output Of A Modern Commercial Building

Pilkington Suncool One Handling and Processing Guidelines

ACTIVE SOLAR SYSTEMS

PassiveDesign.org. Principles of Passive Design

CMR Journal of Engineering and Technology Vol.2 Issue.2 April, 2018

Sustainable Building Façade and Advanced Fenestration Systems

The Renner Residence 2009 Mike and Elida Renner

Laird Thermal Systems Application Note. X-ray Cooling in Industrial Scanners

Sloped Roofs vs Walls. Problems. Review Roof Components. University of Waterloo and Balanced Solutions

Module 13 Assignment. Integrating Landscape and Buildings. For one of the projects listed below, describe the methods used by the designers

Second Law of Thermodynamics

Simulation Study of Discharging PCM Ceiling Panels through Night - time Radiative Cooling

*Corresponding authors. Tel.: x415, address: (N. Zhu)

Draft proposals for Test methods for close-coupled solar water heating systems - Reliability and safety

Application technology, 5th edition. Volume III: Fonterra radiant heating and cooling

Thermal Storage Vessel Sizing

Modernization of Pusher Type Furnace #2 and #3 at Erdemir, Eregli, Turkey. Reining Heisskühlung For more than 65 years: the name says it all

Project name Gentoo Retrofit Bid 1 Project summary Refurbishment of 2no. Semi Detached houses using Passivhaus principles

Thermal comfort in a 21st century climate

Section 5. Renewable Energy Sources Solar and Wind. What Do You See? Think About It. Investigate. Learning Outcomes

Audit your energy use and identify savings

Change of Phase. Heat added. Start: ice at - 20 C. Temperature in C 100 C 0 C -20 C. boil water. heat water. heat steam. melt ice.

Experimental investigation of photovoltaic-thermal hybrid solar collector

Endless Possibilities Use of Heat Pipe for Global Warming Reduction

Olivet Nazarene University Student Life and Recreation Center Project By Elara Engineering

!"#$%&"#'"$( (% +, -

1. Heat Pumps contribute to Environmental Protection and Energy Security Heat Pumps Ambient Heat 23.5 Recycling Grid electricity + Heat pump

ABOUT ICERTECH OUR RANGE TILE-BOX & EASI-CHILL FOIL-BOX & ICER-PACK MOULDED SOLUTIONS ICER-ENVELOPE ICE SHEETS & SUB-ZERO FOIL LINERS SUNDRY PACKAGING

546: High Altitude Design, Optimising Residential Architecture in the Alborz Mountains, Iran

Small thermal energy storage units filled with microencapsulated PCMs for building applications

Mid Street - Achieving Code Level 5

Solar Energy Technologies

Natural Ventilation in Schools and Commercial Buildings (CPD No. 31) Issue 2 May 2017

NATURAL VENTILATION STRATEGIES FOR COMMERCIAL BUILDINGS

Slurry-Based Semi-Solid Die Casting

The PowerOptimal Elon TM The Most Cost-Effective Solar Water Heating Solution

The Heat Rejection System of the ITER Reactor

EcoCore. Phase Change Technology for Energy Efficiency

Figure 1(a) The maximum mass of ice melted (m) for difference mass of liquid X (M) are obtained and recorded in Table 1.

UCARSOL AP 804 and AP 806 Solvents

Andrew Bissell CEO Sunamp

WINERY ENERGY SAVER TOOLKIT SUPPLIER CHECKLIST COMPRESSED AIR

Sonoma County Energy Independence Program APPENDIX A ELIGIBLE IMPROVEMENTS

Passivhaus Introduction

Solar Passive Techniques: Earth Air Tunnel

Transcription:

TM PlusICE Phase Change Material Passive Cooling Products DAY NIGHT PHASE CHANGE MATERIAL PRODUCTS LIMITED

NATURAL ALTERNATIVE TO REDUCE ENERGY THERMAL ENERGY STORAGE; Thermal Energy Storage (TES) is the temporary storage of high or low temperature energy for later use. It bridges the gap between energy requirement and energy use. A thermal storage application may involve a 24 hour or alternatively a weekly or seasonal storage cycle depending on the system design requirements. Whilst the output is always thermal, the input energy may be either thermal or electrical. Phase Change Materials (PCMs) are products that store and release thermal energy during the process of melting & freezing (changing from one phase to another). When such a material freezes, it releases large amounts of energy in the form of latent heat of fusion, or energy of crystallisation. Conversely, when the material is melted, an equal amount of energy is absorbed from the immediate environment as it changes from solid to liquid. For the majority of applications, PCM solutions have to be encapsulated in sealed containers. To this end, PCM Products Ltd. have developed many different standard type containers as well as custom-made containers for special applications. These containers can be applied to any water or air based TES systems and can be manufactured using our PlusICE Phase Change Materials (PCM) solutions which have operating temperatures between -40ºC (-40ºF) and +117 ºC C (+273 ºF) F). TubeICE TM FEATURES; TubeICE concept is based on custom-made plastic containers filled with our PlusICE Phase Change Materials (PCM) solutions which have operating temperatures between -40ºC (-40ºF) and +117 ºC C (+273 ºF) F). They can be stacked in either cylindrical or rectangular tanks for atmospheric / pressurized systems for a variety of thermal energy storage applications. Once the TubeICE containers are filled with PCM they weigh between 2~3 kg (4.4~6.6 lbs) each depending on PCM type and by simply using standard 50mm (2 ) pipe brackets they can be suspended from the ceiling area to act like a heat absorbing sponge to soak up the rising heat within the enclosure. TubeICE Bracket Using conventional basketry it is possible to hang 12 TubeICE containers per m2 ceiling area and the overall total weight could be in the region of 40kg and in return these tubes can provide anywhere between 1.7 ~2.2 kwh/m2 (0.046~0.057 TRh/ft2) energy storage depending on the PCM type. 1,000mm 250mm 500mm 1,000mm 250mm 150 ~250 mm CEILING Direct Bracket Concealed Bracket 1,000 mm Strip Approx. 12 Tubes / m run Weight = 40 kg Although TubeICE containers are manufactured in 50mm (2 ) diameter by 1,000 mm (~40 ), any other size or shape containers can be manufactured to suit the site requirements. Please consult our technical team for any special and custom-made applications.

INNOVATION FOR ENERGY SAVING TECHNOLOGIES BUILDING SERVICES PASSIVE COOLING APPLICATIONS Warm Absorbed by Cooler Ceiling Tiles PlusICE Cells Cooler Falls Solar Gains Warm Room Rises Cooler Falls DISCHARGE PERIOD Cool Outside PlusICE Cells CHARGE PERIOD Passive cooling relies on naturally occurring night and day time temperature swings. The cool energy available over-night is stored within the PCM and later the stored energy is used to absorb the internal and solar heat gains during day-time for an energy free passive cooling system. University of Westminster, London Passive Office Cooling TubeICE behind Tiles Although we can accommodate 12 TubeICE per m2 (~1 TubeICE / ft2) but for building applications ceiling area is also used for other services, the practical limit could be anywhere between 40~70% of the ceiling area. Design Example; Lets say we have a 100 m2 (1,000 ft2) office space and using 27ºC (81ºF) PCM in 1m (~40 ) long TubeICE which provides us with 0.145 kwh (0.041 TRh) thermal energy storage. Using standard brackets one can accommodate 12 Tube ice per m2 (12 TubeICE per 10 ft2). TubeICE Beams within the false ceiling area Pendle Vale School, Lancs., UK A wide range of PlusICE solutions offer a numerous of air conditioning and comfort cooling applications. PlusICE solutions have been applied for passive cooling tiles, plaster boards and heat pipe passive cooling units as a direct air cooling applications. PlusICE solutions are also successfully applied for passive cooling applications such as chilled ceiling / cooling tower free cooling circuits as well as heat rejection systems. Solar House, Passive Cooling USA Nottingham University Passive Cooling Units In other words, every 1m2 (10ft2) area covered with TubeICE filled with 27ºC (81ºF) PCM provides 1.74 kwh (0.49 TRh) energy storage for the occupied space area. If we assume one could only cover 50% of the ceiling area with TubeICE, the design provides just about 87 kwh (24.7 TRh) energy storage capacity for 100 m2 (1,000 ft2) space. As long as the occupied space temperature goes below 20~22 ºC (70~74ºF) over-night, that would be more than enough to freeze the 27ºC (81ºF) PCM solution and in return this stored free energy is used to absorb heat from the occupied area during day-time. If the high level ceiling temperature during peak day-time remains 4~6 hours above 27ºC (81ºF) PCM which acts like a heat sponge to soak up the heat and that means the stored passive energy could provide as much as equivalent to a 15~22 kw (4.3~6.2 TR) mechanical cooling system.

NATURAL ALTERNATIVE TO REDUCE ENERGY FABRIC ENERGY STORAGE; Many organic solutions can be converted to dust, granule, powder or even rubber forms thereby offering new horizons to Granule accommodate and embed the PCM Rubber solution as part of the building fabric and façade. The addition of as little as 25% PCM into the building fabric increases the building thermal performance 14 times in comparison with the same Beads amount of conventional building materials. As almost all organic solutions do not cause any concern for corrosion they can be simply Seats mixed with the building materials as part of the fabric both externally and internally. Alternatively, PCM mixture can be incorporated as part of the furnishing. Any passive cooling entirely relies on the temperature swing between day and night and as such the selection of the PCM temperature is critical to stay within the middle of high daytime and low night-time temperatures. By simply utilising free cold energy absorbed during night-time used to cool the space during high ambient periods i.e. during day-time or alternatively storing the hot energy during day-time and utilising this stored free energy during night cold periods, one can simply stabilise the space temperature swing and Furniture minimise or may even completely eliminates the energy usage. ENCLOSURE PASSIVE COOLING APPLICATIONS o 45 C Shelter CELLS 0 30 C 0 55 C TUBES Any electrical components generates heat whilst running, if these components are housed in a confined space, the internal temperature of the enclosure can rise well above the upper operational limit of the components, resulting in either shut down or burn out for the system. This is exacerbated if the enclosure is exposed to solar gains, for examples in telecom shelters or gas pipeline stations, exposed control panels etc. Hence, if these electrical enclosures / shelters / mobile phone transmitting boxes are located near to a power source, they are provided with 100% run / stand-by mechanical cooling systems for a safe and reliable operation all year round. However, if the same enclosures are located in remote areas whereby no electricity source is available, one can run the electronics using solar energy / battery set up BUT solar energy can not run a mechanical cooling system. A passive cooling relies on simple the swing between day and night ambient temperatures and by simply storing night free cold energy to use during daytime to keep the shelter inside temperature below the design limits.

INNOVATION FOR ENERGY SAVING TECHNOLOGIES TELECOM SHELTERS PASSIVE COOLING If the telecom shelters are located in remote areas, one can run the electronic systems using solar PV cells and battery packs without the mains power but as the mechanical cooling requires far greater power requirements than the electronic solar power driven mechanical cooling is almost impossible to operate. Heat generated by the electronics plus the solar gains during day time results in the enclosure temperatures exceeding the upper safety limit of the electronic circuits and as result the system shut downs for safety. By simply storing the cold night-time energy in the form of passive cooling PCM beams one can over-come this over heating risk. As the energy is naturally stored free of any primary energy use such as gas, oil or electric it has no running cost. As there are no moving parts, it is also maintenance free and at the end of its useful life it can be fully recycled or disposed of without any environmental issues. TubeICE PCM Beams PCM can be encapsulated either in TubeICE or Beams or any other suitable formats and positioned at high level within the shelter to act as passive cooling modules. ELECTRICAL PANEL PASSIVE COOLING All electrical components and batteries generates heat during no rmal operation and when these components placed in air tight or even ventilated spaces the heat generated by the components accumulate with the enclose and cause over-heating problems. In order to overcome this over-heating risk a PCM passive cooling concept can be applied to regulate the internal temperatures and ensure that the enclosure stays within the design limits. REMOTE PUMP STATIONS PASSIVE COOLING Main oil or gas pipeline pumps and monitoring stations are generally located in very remote areas whereby the mains power generally not available. LIBYAN DESERT PASSIVE COOLING SHELTER Typical Telecom Shelter in Remote Location PCM Products worked with many large petrochemical companies developing custom-made passive cooling applications for their pipeline remote location shelter and electrical / control panels providing either a back-up cooling for the mechanical cooling plant or alternatively a stand alone passive cooling system simply utilising the cold night-time energy to keep the enclosure below its upper operating limit during day-time operation. MAIN FRAME & COMPUTER ROOMS BACK UP PASSIVE COOLING It is common practice to install 100% stand-by air conditioning units for any shelter and computer / data installation but the lack of regular operating hours for the stand-by units result in very high maintenance and risk of none-starter units. PCM based passive cooling back up unit where by the standard mechanical cooling charges the PCM-based secondary unit and in the event of power failure or long weekend periods with no central A/C supply, the PCM-based unit requires only a small DC/AC power provided from the back up system to circulate the air and the energy stored within the PCM can keep the enclosure below its upper limits up to 4~6 hours without any mains power requirement. 14 kwh (4 TRh) BACK--UP MODULE BACK

WORLD LEADER IN ENERGY SAVING TECHNOLOGIES ELECTRONIC PASSIVE COOLING APPLICATIONS When main circuit boards and processors are in operation, they generate considerable heat and if this heat is not removed it accumulates within the confined space and the surrounding temperature rises and if it goes above the maximum operating limit of the electronics ( generally +45 ºC (112 ºF)) the system shuts itself down from the safety protection units. By selecting a PCM that changes phase at a temperature between ambient and the upper operational limit, cool energy can be stored during unused periods. Later this stored energy acts like a heat sponge to soak up the heat from the circuit. Heat generated by the electrical equipment is absorbed by the PCM and in return the enclosure temperature is maintained below the upper limit of the system for a safe and reliable operation. In particular, organic solutions are non-conductive as well as non-corrosive and therefore they are safe to contact directly any electrical component. The recently developed thermoformed version of our organic PCM solutions or solid-solid PCM products can be moulded into any shape and as it does not turn liquid even during phase change it offers a leak and effectively risk free operation. Alternatively, PCM solutions can be encapsulated in either metal or plastic containers / pouches to act as heat sinks to suit a variety of temperature range and applications. DATA PROTECTION HEAT SHIELD DATASAFE PLATES When a data logger is placed in excessively hot locations like engine tests, ovens, furnaces etc., it may be exposed to temperatures greater than the recommended maximum operating temperatures. Some logger can cope as high as 110 ºC (240 ºF) but beyond that they are damaged beyond repair. Insulation delay this heat conduction and offers limited time, but by simply adding PCM as part of the insulation kit the standard time delay of this heat migration can be increased by as much as 10~20 times and effectively the logger can be kept within the high temperature environment far longer than by using conventional insulation alone. A number of manufacturers offer safes for data back up. Although they offer protection against direct combustion of the content, the internal temperature of the safe may rise to excessive levels if exposed to fire for any length of time. This can render sensitive storage media such as data disks, tapes, CDs and DVDs useless. By simply incorporating a PCM thermal shield in to the safe, the contents can be protected from the outside temperatures for much longer. BATTERY COOLING Battery Cell During their charging and discharging period all batteries generates heat and if the batteries are located within a sealed enclosure this heat can become excessive. Battery Packs The higher the temperature the greater the life of the battery is reduced. Additionally, the holding power as well as the output during discharge are reduced significantly. By simply incorporating PCM heat sinks which are charged under standard ambient conditions and later this stored PCM energy absorbs the heat generated by the batteries during charging or discharging periods. PCM heat sinks overcome the fluctuation of the battery temperatures which can be stabilised for a reliable, safe operation and extended life. BATTERY COOLING TECHNICAL SUPPORT For additional information contact; PCM Products offers full system design support to assist in proper selection and integration into existing or new installations as well as product development services from conception to completion as part of our customer commitment. We offer full consultancy basis and the possibility of for local manufacturing. sales@pcmproducts.net www.pcmproducts.net on product development on a strict confidentiality Licensee, know-how and technology transfer options Please consult our technical sales team at for your specific application or visit our web site Distributor / Installer Stamp PHASE CHANGE MATERIAL PRODUCTS LIMITED Unit 32, Mere View Industrial Estate, Yaxley, Cambridgeshire, PE7 3HS, United Kingdom Tel: +44-(0)-1733 245511 Fax:+44-(0)-1733 243344 e-mail:info@pcmproducts.net www.pcmproducts.net 2010 Phase Change Material Products Ltd. Printed in England; Passive Cooling 2010-1