IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 05, 2016 ISSN (online):

Similar documents
IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 09, 2014 ISSN (online):

A Study on Positioning of Different Shapes of Shear Walls in L Shaped Building Subjected to Seismic Forces

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 08, 2016 ISSN (online):

Effect of Partial and Central Opening of Masonry Infill Wall in Multi- Storey Building

Comparative Analysis of Moment Resisting Frames of Steel and Composite Materials

Seismic Behavior of High Rise Building for Soft Soil in All Seismic Zones Shaik Fayaz 1 Mrs. B.Ajitha 2

Seismic Analysis of a Multi-Storeyed Building with Irregular Plan Configuration Using ETABS N. Mohan Reddy 1 Dr. E. Arunakanthi 2

IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 07, 2014 ISSN (online):

SEISMIC BEHAVIOR OF RC BUILDING FRAME WITH STEEL BRACING SYSTEM USING VARIOUS ARRANGEMENTS

Seismic Performance of Multistorey Building with Soft Storey at Different Level with RC Shear Wall

Analytical Study on Seismic Performance of Hybrid (DUAL) Structural System Subjected To Earthquake

Linear and Non Linear (Pushover) Analysis of An Irregular Shape Multistorey Building with Different Shear Wall Position

ANALYSIS AND EVALUATION OF STRUCTURAL SYSTEMS WITH BRACING AND SHEAR WALL

Seismic Analysis of Earthquake Resistant Multi Bay Multi Storeyed 3D - RC Frame

Ajay H A 1, Vijay Kumar Y M 2, Suresh Chandra 3 1 P.G. Student, 2 Assistant Professor, 3 Professor. IJRASET: All Rights are Reserved

Effect of Mass and Stiffness of Vertically Irregular RC Structure

EFFECT OF DIFFERENT SHEAR WALL CONFIGURATIONS ON SEISMIC RESPONSE OF A MOMENT-RESISTING FRAME

DYNAMIC RESPONSE OF MULTISTORIED BUILDING WITH AND WITHOUT IN-FILL WALLS

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 07, 2016 ISSN (online):

Comparative Study of Multi-storeyed RC Building With Open Ground Storey Having Different Type Infill Walls

SEISMIC RESPONSE OF A MID RISE RCC BUILDING WITH SOFT STOREY AT GROUND FLOOR

International Journal of Scientific & Engineering Research, Volume 5, Issue 5, May ISSN

SEISMIC EVALUATION OF RC MULTISTOREY BUILDING OF ASYMMETRIC PLAN WITH VISCO-ELASTIC DAMPER

Comparison of Seismic Performance of Solid and Hollow Reinforced Concrete members in RCC framed Building using ETABS Software

Seismic Performance Of R C Flat-Slab Building Structural Systems

Studies on Regular and Irregular Tall Structures Subjected to Earthquake Loading

Research Article Volume 6 Issue No. 6

EARTHQUAKE ANALYSIS OF A G+12 STOREY BUILDING WITH AND WITHOUT INFILL FOR BHUJ AND KOYNA EARTHQUAKE FUNCTIONS

International Journal of Advance Engineering and Research Development

SEISMIC ANALYSIS OF SIX STOREYED RC FRAMED BUILDING WITH BRACING SYSTEMS

SEISMIC ANALYSIS OF SIX STOREYED RC FRAMED BUILDING WITH BRACING SYSTEMS

International Journal of Advance Engineering and Research Development SEISMIC ANALYSIS ON BUILDING WITH HORIZONTAL AND VERTICAL IRREGULARITIES

Linear Analysis of Multistorey Irregular RCC Buildings with Different Sections of X-Bracing

Seismic Retrofitting of Building with Soft Storey and Floating Column

Optimization of Multistory Building with Multi- Outrigger System and Belts Truss

Significance of Shear Wall in Multi-Storey Structure With Seismic Analysis

Pushover Analysis Of RCC Building With Soft Storey At Different Levels.

Seismic Analysis of Buildings with Shear Wall having Horizontal Irregularity

Seismic analysis of vertically geometric irregular structures

STUDY ON EFFECT OF OPEN GROUND STOREY ON SEISMIC PERFORMANCE OF HIGH RISE BUILDING

EARTHQUAKE LOADS ON MULTISTOREY BUILDINGS AS PER IS: AND IS: : A COMPARATIVE STUDY

Miss. Sayli S Kamble. 1, Prof. Dr. D. N. Shinde 2 1 Department of civil Engineering, PVPIT Budhgaon, Shivaji university, Maharashtra, India.

Effect of Shear Wall Area to Floor Area Ratio on the Seismic Behavior of Reinforced Concrete Buildings

Dynamic Analysis of High Rise Flat Plate Building with Different Retrofitting Systems

Earthquake Analysis of Multi Storied Residential Building - A Case Study

A Study on Seismic Analysis of High Rise Irregular Floor Plan Building with Different Position of Shear Walls

Behaviour of Multistory Steel Structure with Different Types of Bracing Systems (A Software Approach)

Seismic Behavior of Soft First Storey

International Journal of Advance Engineering and Research Development. Comparative study for Seismic Analysis of building using different software

Analysis of Flat Slab and Waffle Slab in Multistorey Buildings using ETABS

Parametric Study of Dual Structural System using NLTH Analysis Ismaeel Mohammed 1 S. M. Hashmi 2

Parasiya et al., International Journal of Advanced Engineering Research and Studies E-ISSN

SEISMIC DEMAND STUDY OF SOFT STOREY BUILDING AND IT S STRENGTHENING FOR SEISMIC RESISTANCE

PARAMETRIC STUDY ON VERTICAL IRREGULAR HIGH RISE REINFORCED CONCRETE FRAMED BUILDING

Seismic Analysis of RC Framed Building for Different Position of Shear wall

ANALYSIS OF G+15 RCC AND COMPOSITE STRUCTURE HAVING A SOFT STOREY AT GROUND LEVEL BY RESPONSE SPECTRUM AND EQUIVALENT STATIC METHODS USING ETABS 2013

SEISMIC PERFORMANCE OF HIGH-RISE BUILDING

COST MODELING OF RC BUILDINGS DESIGNED IN DIFFERENT SEISMIC EFFECTS

Project Title. Comparative Study of Shear wall in multistoried

Pushover Analysis of RC Bare Frame: Performance Comparison between Ductile and Non-ductile detailing

Seismic and Wind Effects on High Rise Structure Using ETABS

STUDIES ON LOCATION OF SHEAR WALL IN BUILDINGS FOR STRUCTURAL STABILITY

Comparative Study of Equivalent Static Analysis and Response spectrum analysis on Flat Slab Using Etabs

A Performance Based Evaluation of a Wall- Frame Structure Employing the Pushover Analysis Tool

EFFECT OF CHANGE IN THICKNESSES AND HEIGHTS IN SHEAR WALL ON DEFLECTION, STORY DRIFT AND STIFFNESS OF MULTISTORIED BUILDINGS

COMPARATIVE STUDY ON DESIGN RESULTS OF A MULTI-STORIED BUILDING USING STAAD PRO AND ETABS FOR REGULAR AND IRREGULAR PLAN CONFIGURATION

Seismic Base Isolation of RC Frame Structures With and Without Infill

Study of seismic effect on buildings modified with shear wall

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

SEISMIC EVALUATION OF HIGH RISE STEEL STRUCTURES WITH AND WITHOUT BRACING

SEISMIC BEHAVIOR OF DIFFERENT BRACING HIGH RISE RCC BUILDINGS

Effect of RC Shear Wall on Seismic Performance of Building Resting on Sloping Ground

Approximate Seismic Analysis Procedure for Multibay RC Framed Structures

Effect of Soft Storey on Structural Response of High Rise Building

Comparative Study on Concentric Steel Braced Frame Structure due to Effect of Aspect Ratio using Pushover Analysis

EFFECTS OF P-DELTA ON HIGH RISE BUILDINGS LOCATED IN SEISMIC ZONES

Dynamic analysis of RC frame braced tube structure

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 07, 2016 ISSN (online):

SEISMIC ANALYSIS OF HIGH RISE BUILDINGS WITH PLAN IRREGULARITY

Analysis of Reinforced Concrete Building with Different Arrangement of Concrete and Steel Bracing system

REVIEW OF BRICK MASONRY ON EARTHQUAKE PERFORMANCE OF STRUCTURE

A Comparative Study of Seismic Response of Flat Slab Structure and Conventional RC Framed Structure

International Journal of Advance Engineering and Research Development

Research Article Volume 6 Issue No. 7

Comparative Study of Seismic Analysis between Conventional RC Frame and Flat Slab with Drop Muniraju K.S 1 Subramanya K.G. 2

Study of Strength of RC Shear Wall at Different Location on Multi-Storied Residential Building

A Comparative Study of Stress Parameters Obtained by STAAD-Pro and ETAB

Modelling and Analysis of Irregular Geometrical Configured RCC Multi- Storey Building Using Shear Wall

SSRG International Journal of Civil Engineering ( SSRG IJCE ) Volume 4 Issue 6 June 2017

Seismic Analysis and Design of Regular and Irregular Framed Commercial Buildings

Study On Performance Of Regular And Vertically Irregular Structure With Dampers, Shear Wall And Infill Wall

Stability Analysis of Multi-story building with underneath Satellite Bus Stand having intermediate soft-story and Floating columns

ANALYSIS OF P-DELTA EFFECT ON HIGH RISE BUILDINGS

Static Analysis of Multistoreyed RC Buildings By Using Pushover Methodology

Seismic Behaviour Of Flat Slab Framed Structure With And Without Masonry Infill Wall

COMPARATIVE STUDY OF SEISMIC FORCES BASED ON STATIC AND DYNAMIC ANALYSIS AS PER IS:

TO STUDY THE PERFORMANCE OF HIGH-RISE BUILDING UNDER LATERAL LOAD WITH BARE FRAME AND SHEAR WALL WITH OPENINGS

International journal of scientific and technical research in engineering (IJSTRE) Volume 1 Issue 4 ǁ July 2016.

Lateral Stability Analysis of High Rise Building with the Effect of Outrigger and Belt Truss System

THE INTERNATIONAL JOURNAL OF SCIENCE & TECHNOLEDGE

Transcription:

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 05, 2016 ISSN (online): 2321-0613 Seismic analysis of RC Building Frame with Different Bracing Systems Mohammed Ali Khan 1 Prof S.M Hashmi 2 Prof Shaik Abdulla 3 1 P.G. Student 2 Associate Professor 3 Assistant Professor 1,2,3 Department of Civil Engineering 1,2,3 Khaja Banda Nawaz College of Engineering, Gulbarga, Karnataka State, India Abstract In multistoried buildings steel braced frames is used in resisting lateral loads. For strengthening or retrofitting seismically inadequate reinforced concrete frame the use of steel bracing is a viable solution for inducing seismic resistance. An analytical study is required to be performed to gain understanding into the behavior of braced frame under earthquake loading. By using steel bracings drift is controlled and collapse is prevented. Steel bracings system occupies less space, easy to erect and has flexibility to design for meeting the required strength and stiffness. In RC buildings strength and stiffness is increased by the use of steel bracings to be safe against natural forces like Earthquake. In this study G+15 building frame is analyzed with different bracing systems under seismic loading in seismic zones III, IV, V. as per IS 1893-2002. E-TABS Software is used for the analysis of the building frame. The results of various bracing systems (X-Bracing, V-Bracing, K- Bracing, Inverted V-Bracing, and Inverted K-Bracing) are compared with bare frame model analysis. The effectiveness of various types of bracing systems is studied in order to control the lateral displacement, storey drift & member forces in the frame. It is found that all the bracing systems control the lateral displacement very effectively. Therefore the object of the study is to determine the degree of effectiveness of different bracing arrangements to increase the sustainability of the RC frame against the effects of Earthquake. Key words: Different Bracing Systems, RC Building Frame I. INTRODUCTION Structures are built to facilitate the performance of various activities, and all the structures should be capable of sustaining the loads coming on them during the service life of the structure. Structure should have adequate strength, stiffness and durability. Strength of the structure depends on the quality of materials used for the construction and stiffness depends on the geometrical as well as cross sectional property of the structure. Earthquake happens when there is a disturbance at some depth below ground level causing the vibration of ground surface. These vibrations are totally uncertain and happen in all directions. Earthquakes are highly unpredictable. Earthquakes are generally a geological hazard or those living in earthquake prone areas. Earthquake cause ground to shake and structure support on it is subjected to vibration. Therefore the dynamic loading on the structure is not an exterior loading, but due to movement of the supports. Earthquake ground motion is a natural hazard which causes both financial and living losses. Most of these losses is a result of damage of structure or collapse of building. Hence it is necessary to design the structure to defend against reasonable to rigorous earthquake. Structure is subjected in the direction of seismic forces for the duration of an earthquake. The wave beginning the earthquake reaches the structure through soil or rock medium it produces motions inside the structure. These motions depend on the characteristic of the structure. For the structure to respond to this motion, it needs to conquer its own inertia, which results in an interaction among the structure and the soil. Soil structure interaction is the phenomenon which involves the study of the affiliation between structure and soil. Such a mutually dependent behavior among soil and structure regulating the overall response is known as Soil Structure Interaction. II. LITERATURE REVIEW Youssef et. al (2007)[5], has studied the efficiency of braced steel frames. They were conducted two cyclic load test on moment frame as well as a braced frame. Moment frame is designed according to existing seismic codes. They were observed that steel bracings are one of the successful systems in resisting lateral loads. Though it is used to promote the lateral load capability of existing RC frames has been the subject of various studies, guidelines for the use in recently constructed RC frames is still require to be developed. They adopt a rational design methodology to design the frame together with the associations between the brace members and the concrete frames. The investigation results showed the braced frame resist higher lateral loads than moment resisting frame and provide sufficient ductility. The adopted methodology for the designing the braced frame resulted in an reasonable seismic performance and represents the first step in the expansion of design guidelines for these types of frames. Vishwanath et. al (2010)[7], have analyzed an four storey structure for the seismic zone IV as per IS 1893-2002 by using E-Tabs Software. They examined usefulness of a variety of type of the steel bracing in rehabilitation a 4 storey building. They observed that the steel braced frame is one of the structural system used to counter earthquake load in multistoried building. The steel bracing is inexpensive, simple to erect, occupy less space and has flexibility to design for the necessary strength and stiffness. The bracings are provided for peripheral columns. They observed that x- type of steel bracings appreciably contribute to the structural stiffness and reduces the max inter storey drift of the frames. They conclude that the idea of using steel bracing is one of the beneficial concepts which can be used to strengthen or retrofit the existing structures. The building frames with x- bracing systems will have least possible bending moment in association to the other types bracing. R.K. Gajjar, Dhaval P. Advani (2011), investigated the design of the multi storied building to has superior lateral load resisting system along with the gravity load system because it govern the design. They demonstrate the effect of different types of bracing systems in multi the storied buildings. In support of this reason the 20 stories building model is used with same configuration and different bracing systems such as X bracing V bracing is All rights reserved by www.ijsrd.com 1269

used. A marketable package E-tabs is used for analysis and design and the different parameter are compared. Kevadkar, Kodag et al (2013), concluded that the structure in heavy susceptible to lateral forces may be concern to severe damage. In this they said along with gravity load (dead load, live load) the frames able to withstand to lateral load ( loads due to earthquake, wind, explosion, fire hazards etc) which can extend high stresses for that purpose they used bracing system to resist such type of loading like earthquake, wind etc. In study according to author R.C.C building is model, analyzed in E-Tabs & results are compared in terms of Lateral Displacement, Storey shear & storey drifts. Abhijeet Baikerikar (2014)[1], Braced frames can resist large amount of lateral forces and have reduced lateral deflection and thus reduced P-Delta effect. In the present study the author have use grid of 20m in each direction of 5m bay in each direction, software used is E-Tabs 9.7.0, he has compare the outcome of bare frame and braced frame and found the result that braced frame significantly lower the lateral displacements and drifts compared to bare frame and thus resisting earthquake forces efficiently. The study have been carried out for the zone V and soft soil as specified in IS 1893-2002. The analysis results showed that bare frame produces larger displacements and drifts compared to other frames with bracing systems. 7 Beam size in X 0.3 m x 0.70 m 8 Beam size in Y 0.3 m x 0.50 m 9 Slab thickness 150 mm 10 Unit weight of masonry wall 20 kn/m Table 1: Detailed Data for the Building V. LOADS Wall load in X-direction 11.8 kn/m Wall load in Y-direction 12.6 kn/m Floor finish 1 kn/m2 Live load 4 kn/m2 Earthquake Zone III, IV, V Response reduction Factor: 5 Importance factor: 1 Damping: 5% Soil type: Hard Soil VI. EARTHQUAKE LOADS III. MODELING E-TABS software is used for the 3D model and analysis of the building. The software is capable of predicting the behavior of space frame under different loading conditions, considering both geometric non linearity and material in elasticity. The software has the capacity to perform static analysis and as well as dynamic analysis. A. Model Description The building is model as a series of load resist elements. Based on the Indian standard code lateral loads are apply on the building. The study is performed for seismic zones III, IV, V as per IS 1893 (part 1): 2002. The building considered consists of reinforced concrete and brick masonry element. The building is assumed to be tightly fixed at the base storey. Fifteen storey building is analyzed for gravity loads and seismic forces. Model is analyzed for different bracing systems such as X Bracing, V Bracings, K-Bracings, Inverted V & Inverted K bracings. Both Equivalent static and Response spectrum method of analysis is been performed for analysis. IV. DETAILED DATA FOR THE BUILDING Sl. No. Description Parameter 1 Depth of foundation 2.5 m 2 Floor to floor height 3.5 m 3 Grade of concrete M 30 4 Grade of steel HYSD-500 5 Column size (bottom 3 storey s) 0.85 m x 0.85 m 6 Column size (top 12 storey s) 0.75 m x 0.75 m Fig. 1: Plan of Proposed Structural Frame Fig. 2: Elevation of proposed structural Frame Fig. 3: Bare Frame Fig. 4: X- Bracings All rights reserved by www.ijsrd.com 1270

Fig. 5: V-Bracings Fig. 6: K-Bracings A. Base Shear Base shear is the total lateral force on the structure. During the earthquake structures do not remain stiff, it deflects, and thus base shear is distributed all along the height of the building. The base shear of bare frame and different bracings systems of the frame for seismic zones III, IV, V are found. The values obtained from the analysis are tabulated in the Table 2 & 3 and in fig 7.1&7.2. Bare Frame 3192.92 4789.38 7184.03 X Bracing 3695.39 5543.09 8314.64 V Bracing 3713.76 5570.64 8355.97 K Bracing 3513.26 5269.89 7904.86 Inverted V Bracing 3746.45 5619.67 8429.51 Inverted K Bracing 3543.81 5315.71 7973.57 Table 2: Base Shear EQX (KN) Bare Frame 2559.54 3839.28 5758.92 X Bracing 3042.90 4564.35 6846.53 V Bracing 2941.62 4412.44 6618.66 K Bracing 2683.59 4025.39 6038.09 Inverted V Bracing 2976.99 4465.48 6698.23 Inverted K Bracing 2701.52 4052.28 6078.42 Table 3: Base Shear EQY (KN) Fig. 7: Inverted V-Bracings Fig. 9: Base Shear EQX (KN) Fig. 8: Inverted K-Bracings VII. RESULTS AND DISCUSSION The results for displacements, Base shear, storey Drift, Bending moment & Shear force in Beams and Columns for different building models are presented. Based on the results the most suitable type of bracing is suggested for strengthening of the structure. Hence effect of addition of different types of bracings systems is studied by performing seismic analysis. Fig. 10: Base Shear EQY (KN) From table 2 & 3 following observations are made. It has been observed that the base shear EQX and EQY is least for bare frames in all zones considered, as compared to different bracings systems. The base shear EQX is maximum in Inverted V- Bracings for all seismic zones considered. All rights reserved by www.ijsrd.com 1271

The base shear EQY is maximum for X-Bracings for all seismic zones considered. B. Max SF and BM in Columns and Beams The maximum SF and BM for Beams and Column are obtained in bare frames in seismic zones III, IV, V. and it is compared with all type of bracings considered. It is practical that bracings decrease the SF and BM in Beams and Columns. The values thus obtained are presented in the tables 4 to 5. Bare Frame 539.63 805.67 1204.72 X Bracing 623.95 918.44 1360.17 V Bracing 585.80 867.96 1291.20 K Bracing 545.93 815.49 1219.85 Inverted V Bracing 603.01 890.17 1320.90 Inverted K Bracing 545.82 808.74 1209.09 Table 4: Maximum moments M2 (KN-m) in Columns: K Bracing 308.77 375.26 555.84 Inverted V Bracing 311.22 323.29 478.03 Inverted K Bracing 309.62 372.47 551.65 Table 6: Maximum Shear Force V2 (KN) in Beams Fig. 7.5: Max Shear Force V2 in Beams Bare Frame 480.09 574.33 729.94 X Bracing 463.81 512.24 629.76 V Bracing 459.70 509.41 626.14 K Bracing 461.27 533.15 666.82 Inverted V Bracing 463.86 510.92 625.54 Inverted K Bracing 463.12 534.12 666.72 Table 7: Maximum Bending Moment M3 (KN-m) in Beams Fig 7.3: Max Moments M2 in Columns Bare Frame 483.12 714.21 1069.55 X Bracing 603.09 878.70 1292.10 V Bracing 595.17 872.66 1288.89 K Bracing 559.82 819.31 1208.56 Inverted V Bracing 628.01 910.38 1333.92 Inverted K Bracing 582.95 844.71 1237.35 Table 5: Maximum moments M3 (KN-m) in Columns Fig. 5: Max moments M3 in Columns Bare Frame 308.06 395.89 586.78 X Bracing 311.21 311.21 457.76 V Bracing 310.07 328.80 486.16 are made Fig. 7.6: Max moments M3 in Beams From the Table 4 to 7 the following observations It has been seen that shear force and bending moments are maximum in zone V as compared to zone III, IV. The seismic intensity of zone V is very severe. Shear force V2 in beams is least for X-Bracings as compared to other types of bracings. Shear force is maximum for bare frame in all seismic zones. Bending moments M3 in beams is maximum in bare frames while compare to other type of bracing systems. BM in beams is least in V-Bracings in all seismic zones. C. Lateral Displacements The maximum lateral displacements for different bracing systems in zones III, IV, V are presented in tables 7.7 to 7.10 for Equivalent Static Method and Response Spectrum Method. On behalf of enhanced comparability lateral displacements at each floor level for all bracings systems bare frame, X, V, K, Inverted V, Inverted K Bracing All rights reserved by www.ijsrd.com 1272

systems in all seismic zones considered in this analysis is presented in tables. Displacements (mm) Structure in X (Transverse) Direction Bare Frame 39.5 59.2 88.8 X Bracing 35.6 53.5 80.2 V Bracing 35.5 53.2 79.8 K Bracing 36.6 54.9 82.3 Inverted V Bracing 35.2 52.7 79.1 Inverted K Bracing 36.2 54.3 81.5 Table 8: Max Lateral Displacement in Frame: Equivalent Static Method Fig. 7.7: Max lateral displacement in X direction Displacements (mm) Structure in Y (Transverse) Direction Bare Frame 63.1 94.6 141.9 X Bracing 53.4 80.1 120.1 V Bracing 54.5 81.8 122.6 K Bracing 59.0 88.6 132.8 Inverted V Bracing 53.8 80.7 121.0 Inverted K Bracing 58.5 87.8 131.7 Table 9: Max Lateral Displacement in Frame: Equivalent Static Method Fig. 7.8: Max Lateral displacement in Y direction Displacements (mm) Structure in X (Transverse) Direction Bare Frame 19.2 28.9 43.3 X Bracing 17.1 25.6 38.4 V Bracing 17.0 25.6 38.3 K Bracing 17.7 26.5 39.7 Inverted V Bracing 16.9 25.3 38.0 Inverted K Bracing 17.5 26.2 39.4 Table 10: Max Lateral Displacement in Frame: Response Spectrum Method Fig. 7.9: Max lateral displacement ix X direction Displacements (mm) Structure in Y (Transverse) Direction Bare Frame 24.6 37.0 55.5 X Bracing 21.6 32.3 48.5 V Bracing 22.0 33.0 49.5 K Bracing 23.6 35.5 53.2 Inverted V Bracing 21.8 32.6 49.0 Inverted K Bracing 23.4 35.2 52.8 Table 11: max Lateral Displacement in Frame: Response Spectrum Method Fig. 7.10: Max lateral displacement in Y direction From Table 8 to 11 the following observations are made The lateral displacement is found to be maximum for zone V than the building located in zone III, IV. The seismic intensity of zone V is very severe. The lateral displacement is maximum for roof level and decreases gradually at lower storey s. The bare frames have greater lateral displacements than the frames with the different bracings systems in all seismic zones considered. X-Bracing system is found further effective in reducing lateral displacement in seismic zones III, IV, V. The building frames with X-Bracing systems have min probable lateral displacement as compared to other types of bracing systems. D. Storey Drift It is the displacement of one floor with respect to the other floor below or above. Is1893-2002 specifies the storey drift in any storey due to the min specific design lateral force, shall not go over 0.004 times the storey height. So the minimum damage would take place during the earthquake. All rights reserved by www.ijsrd.com 1273

The storey drift at each floor of different frame models for different bracing systems in seismic zones III, IV, V is presented in fig below. [6] IS 456-2000, Code of Practice for plain and Reinforced Concrete, Bureau of Indian Standards, New Delhi, India. [7] IS 875-1987 (Part 1) Code of Practice for design loads (other than Earthquake) for building and structures, Bureau of Indian Standards, New Delhi, India. [8] IS 875-1987 (Part 1) Code of Practice for design loads (other than Earthquake) for building and structures, Bureau of Indian Standards, New Delhi, India. Fig. 7.11: Seismic Zones VIII. CONCLUSIONS In the present work, behavior of braced RC frame has been studied by performing analytical investigations. A RC building frame has been analyzed bare frame model and by providing different bracing systems. The following are the conclusions, 1) The conception of using steel bracing is beneficial which can be used to resist the seismic forces. 2) By providing steel bracings lateral displacement is been considerably reduced when compared to bare frame. 3) Bracing reduces the forces in the members of the frame. 4) Steel bracings may be used as a retrofitting to the existing building. 5) By using steel bracings as a force resisting member the safety against collapse of the structure has been increased. 6) Bracing reduces storey drift more efficiently as compared to bare frame. 7) Bracings reduce the BM and SF in Beam and Column, and the lateral load is transferred axially. 8) The X-Bracing system has least lateral displacements in all seismic zones considered, as compare to other type of bracing systems. 9) Steel bracings for RC frame are the major lateral load resisting system for RC structure. REFERENCES [1] Pankaj Agarwal & Manish Shrikhande. Earthquake Resistant Design of Structures. [2] Prentice-Hall of India pvt ltd New Delhi India, 2014 [3] S.K Duggal Earthquake Resistant Design of Structures. [4] Oxford University Press, New Delhi, 2009 [5] IS 1893-2002 (part 1) Criteria for Earthquake Resistant Design of Structures, Part-1 General Provisions and buildings, fifth Revision, Bureau of Indian Standards, New Delhi, India. All rights reserved by www.ijsrd.com 1274