Agilent 7820A GC System THE EASY CHOICE FOR ROUTINE ANALYSES

Similar documents
Agilent 7820A GC and Agilent 5977E Series GC/MSD YOUR BEST VALUE FOR ROUTINE GC AND GC/MS ANALYSIS

Agilent 7820A GC Agilent 5975E GC/MSD. Your best value for routine GC and GC/MS analysis. The Mea sure of Confidence

easy. HPLC has never been so Agilent 1120 Compact LC Our measure is your success.

SCION GC Series. The Gas Chromatographers Choice for Separations

SCION GC Series. The Gas Chromatographers Choice for Separations

Agilent 7693A Series Automatic Liquid Sampler. Inject new performance into your gas chromotography

Agilent OpenLAB CDS. Manage your chromatography better than ever before

AGILENT INFINITYLAB. Maximum efficiency for your liquid chromatography workflows

SCION GC Series. The Gas Chromatographers Choice for Separations

Agilent OpenLAB Chromatography Data System IT S TIME TO ACHIEVE MORE

Agilent 7693A Series Automatic Liquid Sampler INJECT NEW PERFORMANCE INTO YOUR GAS CHROMATOGRAPHY

Agilent 218 Purification System. Purify your way

NATURALLY BETTER CHROMATOGRAPHY SOLUTIONS. Clarus Gas Chromatographs Clarus 680/580/480

Agilent 7693A Series Automatic Liquid Sampler Inject new performance into your gas chromatography. Our measure is your success.

INCREASING YOUR LABORATORY PRODUCTIVITY

Agilent 1260 Infinity II Prime LC ACHIEVE CONVENIENCE EVERY DAY IN EVERY WAY

Agilent 7693A Series Automatic Liquid Sampler INJECT NEW PERFORMANCE INTO YOUR GAS CHROMATOGRAPHY

Agilent 8355 Sulfur Chemiluminescence Detector REIMAGINED. REDESIGNED.

Agilent OpenLAB Chromatography Data System COMPLIANCE AND EASE OF USE, TOGETHER AT LAST

Agilent 1220 Infinity II LC GET ON THE FAST TRACK TO HIGHEST EFFICIENCY AT A PRICE YOU CAN AFFORD

Optimizing Productivity and Reliability for Monocyclic Aromatic Hydrocarbon Purity Analysis According to ASTM D7504 on the Agilent 8890 GC System

Agilent SD-1 Purification System. Purify your way SD-1

Agilent 7667A Mini Thermal Desorber MEASURE VOCS IN GAS MATRIX WHEN MOBILITY MATTERS

API 3200 LC/MS/MS system

Analytical HPLC solutions

Agilent 6000 Series LC/MS Solutions. Confidence in Quantitative and Qualitative Analysis

HIGHER IMPACT LC/MS DIAGNOSTICS AGILENT IN VITRO DIAGNOSTIC MEDICAL DEVICES FOR CLINICAL LABORATORIES

Chemical Analysis. DHA Analyzer Family. Optimized Solutions for Detailed Hydrocarbon Analysis. Gas Chromatography. think forward

The Agilent 7890A Gas Chromatograph All the elements for perfect chemistry. Our measure is your success. products applications soft ware services

DANI A SCENT OF FUTURE HIGH PRODUCTIVITY ACCURACY AND PRECISION FLEXIBILITY AND UPGRADEABILITY USER FRIENDLY INTERFACE FAST GAS C HROMATOGRAPH

Chrom-Card Data System. A simple, chemist-oriented data handling system...productive from the first day!

Meet the airgc. Ambient air carrier. Top performance. catalytics accelerated

Ultivo Triple Quadrupole Mass Spectrometer UNBELIEVABLY POWERFUL REMARKABLY SMALL

Agilent OpenLAB Enterprise Content Manager REALIZE THE FULL VALUE OF YOUR SCIENTIFIC DATA

Agilent Intuvo 9000 GC System DREAM BIGGER

Expanding the Versatility of Micro GC in the Shale Gas Play; The Agilent 490 Micro GC offers unprecedented reliability and flexibility

World-leading LC/MS/MS technology for quantitation and identification API LC/MS/MS System

Agilent 1260 Infinity LC & LC/MS Purification Systems. Purify your way

Agilent LC and LC/MS Purification Solutions. Purify your way

Top 10 GC Operation Tools That Drive Lab Productivity

ACCURACY THE FIRST TIME. Reliable testing with performance, productivity and value combined AB SCIEX 3200MD SERIES MASS SPECTROMETERS

Mach-RGA. The Fast Refinery Gas Analyzer. Analyzer

A New Horizon of Performance Agilent G1888 Network Headspace Sampler

The Agilent StreamSelect LC/MS Solution: Increasing the Throughput of a Triple Quadrupole Mass Spectrometer

Agilent 1220 Infinity LC. Infinitely more affordable

ACCURACY THE FIRST TIME. Bring Your Esoteric Assays In-House Routinely SCIEX DIAGNOSTICS MASS SPECTROMETERS

Agilent 1260 Infinity II LC ASPIRE TO NEW LEVELS OF EFFICIENCY EVERY DAY IN EVERY WAY

Prefractionator for Reliable Analysis of the Light Ends of Crude Oil and other Petroleum Fractions

A Rapid Method for Trace Analysis of Organophosphorus Pesticides in Drinking Water

Hydrocarbon Processing Industry Gas Chromatographs. Standard GC Analyzer Solutions

Purification, Purity Analysis, and Impurity Analysis Solutions. for Pharmaceutical Research and Development

Agilent 6400 Series Triple Quadrupole LC/MS. Breakthrough sensitivity now routine for your lab

Agilent InfinityLab LC/MSD Series EXTEND THE BOUNDARIES OF YOUR ANALYSIS

TurboMatrix. Thermal Desorption Solutions

Agilent 1260 Infinity Purification Systems. Infinitely better purity and recovery

Application Note. Author. Abstract. Pharmaceuticals. Detlef Wilhelm ANATOX GmbH & Co. KG. Fuerstenwalde, Germany mau

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

Agilent solutions for contract research and manufacturing organizations

GC8000 Process Gas Chromatograph. Bulletin 11B08A01-01E

Agilent 6490 Triple Quadrupole LC/MS System REACH ULTIMATE SENSITIVITY WITH BREAKTHROUGH IFUNNEL TECHNOLOGY

Agilent MassHunter Walkup Software SIMPLIFIED LC/MS FOR EVERYONE

CTC automated sample injectors for gas chromatography, distributed by Agilent Technologies

Agilent 5100 ICP-OES DUAL VIEW ICP-OES MINUS THE WAIT

Agilent LC Dissolution Software STREAMLINE LC DISSOLUTION ANALYSIS

Agilent Consumables Improve Performance with Shimadzu GC/MS

Gold Standard for recovery and purity

Designed for the Modern Chromatography Lab. Agilent OpenLab CDS

The Fast Track to Success. Pesticides Workflow Solutions for Intuvo GC/TQ

OpenLAB CDS Intelligent Reporting

NEW OUTSIDE DIAMETER FUSED SILICA FOR AGILENT J&W CP AND VF GC COLUMNS

performance and throughput

Performance Characteristics of the Agilent 1220 Infinity Gradient LC system

Performance characteristics of the 1260 Infinity Quaternary LC system

Direct Injection of Fish Oil for the GC-ECD Analysis of PCBs: Results Using a Deans Switch With Backflushing. Application. Author.

Automated Scouting of Stationary and Mobile Phases Using the Agilent 1290 Infinity II Method Development Solution

Capillary GC Troubleshooting: a Practical Approach

It works as hard as you do.

Agilent 7696A Sample Prep WorkBench LC GC LC/MS GC/MS. Automate your most. tedious sample preparation steps with one standalone instrument

APPLICATION NOTE. UOP : Analysis of Trace CO and CO 2 in bulk H 2 and Light Gaseous Hydrocarbons by GC

Faster, easier, flexible proteomics solutions

GC Troubleshooting. Frank Michel, Katherine K. Stenerson T HCE

Resolve Your Search for More Ions: The 5977B, 7000D, and 7010B GC/MS Instruments. Stephan Baumann ASTS Talk November, 2016

Altus UPLC IT S ALL ABOUT PEAK PERFORMANCE

Agilent 2200 TapeStation System ACCELERATE YOUR SAMPLE QC WITH CONFIDENCE

Using a Diode Array UV-Vis in Regulated Environments

2.1 This procedure provides steps and conditions for the determination of Vapor Space Organic Compounds in ground waters, and industrial waste waters.

Hydrogen Generators for Fuel Gas

Enabling routine characterization of proteins. Agilent MassHunter BioConfirm software

Exhibit 22L. Preventive Maintenance (PM), and upon availability, Agilent Remote Advisor is also included.

AOC Shimadzu Front End Automation for Gas Chromatography C189-E027E. Environmental. Foods/Beverages/ Consumer Products.

Please enclose a item wise compliance report along with the technical bid.

ANALYTICAL GAS GENERATORS INNOVATIVE GAS SOLUTIONS FOR YOUR LAB

Gas Generators. Parker Balston

Agilent 1290 Infinity II LC SET NEW BENCHMARKS IN EFFICIENCY WITH THE NEXT GENERATION OF UHPLC

Qualification of High-Performance Liquid Chromatography Systems

ANALYTICAL GAS GENERATORS

Agilent 1290 Infinity 2D-LC Solution. Selectable separation performance

ADVANCES IN MICRO GAS CHROMATOGRAPHY

Analyze more samples. faster. while maintaining resolution. NEW Agilent J&W High Efficiency Capillary GC Columns

Complete Success Begins with Sample Quality Control. Agilent 4150 and 4200 TapeStation Systems

Transcription:

Agilent 7820A GC System THE EASY CHOICE FOR ROUTINE ANALYSES

THE AGILENT 7820A GC SYSTEM FORWARD-THINKING INNOVATION, EVERYDAY RELIABILITY AND VALUE Is your lab looking for better, more reproducible results for all your standard GC analyses, run after run and day after day? Are you looking for proven quality in an affordable solution that maximizes uptime, minimizes maintenance, and provides the highest return on your investment? Here s exactly what you ve been looking for: the 7820A GC system from Agilent. Run after run, day after day, the affordable Agilent 7820A GC delivers the reliability you are looking for and performance you can count on. 2

An easy-to-own choice for labs like yours Now any lab can take advantage of innovative instrumentation, versatile software, and application-matched columns and supplies. This robust GC solution is designed to optimize routine performance, while minimizing complexity. And because it s from Agilent, it gives you the proven quality you expect from the GC industry leader. Consistent, dependable results The 7820A GC offers uncompromising GC performance for all your routine applications including those that must comply with regulatory requirements. Proven electronic pneumatic control (EPC) and digital electronics ensure excellent reproducibility, as well as reliable accuracy and precision. Electronic pneumatic regulation (EPR) provides a precise, easy-to-use, economical alternative to traditional manual pneumatics based systems. Simple 5-button keypad minimizes the chance of operator errors. Easy to learn and operate for all users With an intuitive user interface and minimalist 5-button keypad, the 7820A GC is very easy to operate, even for inexperienced or infrequent users. Because there are no gauges or manual gas knobs, errors are minimized. And with convenient, real-world design features and built-in self-diagnostics, the 7820A GC is also easy to maintain. Lab-proven quality and long-life Agilent reliability Why settle for good enough, when you can invest in quality? With a heritage of more than 50 years of GC innovation, Agilent has earned a worldwide reputation for reliability and uptime under the most demanding operating conditions. Flexible automatic selection for better repeatability and higher productivity With Agilent automated GC injectors and samplers, you can eliminate the variables of manual injection and increase your lab s throughput. These optional accessories offer unprecedented sample handling flexibility, and allow fully unattended operation from injection through final reporting. Proven OpenLAB CDS software platform running in chromatography labs around the world makes it easy for all users to set up and operate the 7820A GC system. (Shown is a 7820A GC method creation screen.) Maximize your uptime with built-in service and support The 7820A GC system s integrated hardware and software simplify your operations with features such as a guided system set-up that helps get you up and running without a visit by an Agilent service representative. And of course, our world-class customer service engineers and certified support partners are available to provide installation, familiarization, training, maintenance, contractual repair, and compliance services. The Agilent 7650A autoinjector provides capacity for up to fifty 2 ml vials To learn more about the Agilent 7820A GC System, visit www.agilent.com/chem/7820a 3

SIMPLIFIED OPERATION AND EXTRA VERSATILITY HELP YOU GET MORE DONE, EVERY DAY The goals that motivate Agilent innovation are your goals: maximum reliability and trouble-free operation under all conditions. And this spirit of innovation is reflected in the engineering features and technology of the 7820A GC. EPC: Setting the standard for performance and control Full electronic pneumatics control (EPC) available on all inlets and detectors ensures a better repeatability of retention times and peak areas. By using the software to set gas flows, you can now save all of the important parameters of your method. Digital electronics keep your set points constant from run to run, and operator to operator. So you get better retention time repeatability, more consistent results, and less rework. Standard high precision inlets Split/splitless (SSL) for large bore and all capillary columns Purged packed injection port (PPIP) for wide bore capillary and packed columns Programmable cool on-column (PCOC) for columns >= 0.250 mm id Automatic valve control For chemical and hydrocarbon processing applications, the 7820A GC system can automatically control up to two heated valves. Retention time and area repeatability split/splitless inlet and FID Compound Retention Time (min) Peak area (pa) 24 C 30 C 24 C 30 C C13 3.7843 3.7820 45.2143 44.5105 C14 4.4213 4.4190 45.5790 44.8429 C15 5.0369 5.0344 457.8670 449.3625 C16 5.6238 5.6211 456.6820 449.5554 Electronic Pneumatic Control (EPC) module for the 7820A GC. High-sensitivity Agilent detectors for every sample type Flame ionization detector (FID): Wide dynamic response range enhances accuracy and minimizes sample prep requirements for samples that contain very high or very low compound concentrations. Nitrogen-phosphorus detector (NPD): Offers superior sensitivity and selectivity for nitrogen- or phosphorus-containing compounds, such as pesticide residues in food and environmental samples. Thermal conductivity detector (TCD): Single-filament design provides lower noise and higher sensitivity for general purpose applications. Electron capture detector (micro-ecd*): Combines unprecedented sensitivity and linearity with ruggedness and reliability an ideal choice if your lab is analyzing halogenated organic compounds such as pesticides, PCBs, and chlorinated solvents. Single wavelength flame photometric detector (FPD Plus): High sensitivity detector specifically for sulphur or phosphorus containing compounds in food, environmental, or petrochemical samples. * Not available in Japan. Retention time and area count changes are minimal even as lab temperatures change throughout the day. 4

NEW EPR: The simplicity of manual operation with high precision digital display, electronic stability, and ease-of-use Electronic Pneumatics Regulation (EPR) provides a simple, precise, and cost-effective alternative to traditional manual pneumatics operation for select inlets and detectors. Based on industry-leading Agilent pneumatics technologies, EPR makes it easy to manually adjust gas pressures and flows electronically. What s more, EPR has built-in ambient temperature and pressure compensation, resulting in more stable retention times and detector baselines than traditional manual pneumaticsbased systems. Pressure (or flow) values are digitally displayed and adjusted manually. There are no pressure or flow set points that can be entered or saved to a method. With EPR, you manually adjust pressures (or flows) higher or lower using the + or - keys on the 7820A software keypad. You can also make these adjustments from a PC positioned near the GC or even remotely. No gauges or bubble meters needed EPR digitally displays pressure and flow significantly improving precision over manual pressure gauges and eliminating the need for inconvenient bubble meters to measure and adjust the flows. You can manually adjust gas pressures/flows electronically, avoiding mechanical regulators, which are susceptible to drift over time and temperature. PRESSURE CARRIER FLOW BUBBLE METER 5

SOFTWARE OPTIONS TO FIT YOUR APPLICATION, WORKFLOW, AND BUDGET Innovative Agilent software platforms help you make the most of every run, and every workday. Agilent OpenLAB CDS EZChrom Compact: Economical data acquisition and analysis Total control of up to two instruments including the 7820A GC, 6820 GC, 490 Micro GC, and Agilent 1220 Infinity LC from one PC Quick access to your most common tasks Pre-defined reports and built-in templates for customized report layouts The ability to upgrade to OpenLAB CDS EZChrom when your needs change View instrument status, current data, and run queue on a single screen Agilent OpenLAB CDS VL: Your choice for value OpenLAB CDS VL lets you choose between ChemStation and EZChrom Editions. Both provide a fully functional OpenLAB CDS workstation for controlling your 7820A GC. Agilent OpenLAB CDS: Comprehensive instrument control OpenLAB CDS Workstation and ChemStation Edition provide full control of Agilent instruments (LC, GC, CE, LC/MS, and CE/MS), while OpenLAB CDS EZChrom Edition adds multi-vendor instrument control. Both editions let you control Agilent Headspace Sampler(s), and allow optional integration with OpenLAB ECM for central data storage, GLP, and compliance features. Area Percent Report Data file: C:\Chem32\1\Data\SIG1000004.D Sample name: Reformate Description: Sample amount: 0.000 Sample type: Instrument: Location: Injection date: 5/1/2013 3:13:30 PM Injection: Acq. method: 40M_DHA_MATCH_CO Injection volume: MPARE.M Analysis method: def_gc.m Acq. operator: Last changed: 8/4/2016 12:25:19 PM Signal: FID1 A, Front Signal RT [min] Type Width [min] Area Height Area% Name 2.643 BB 0.0107 228.6434 354.0616 1.6575 2.839 BB 0.0103 167.7749 248.9219 1.2163 3.202 BB 0.0122 78.1139 101.5645 0.5663 3.593 BV 0.0156 78.2585 78.9631 0.5673 3.655 VB 0.0144 340.3260 382.0947 2.4672 3.883 BB 0.0136 261.5821 292.3715 1.8963 4.188 BV 0.0160 341.0115 330.7862 2.4721 4.680 BV 0.0170 61.4783 58.9600 0.4457 Sample 7 2 of 1 SYSTEM Agilent DA Express Data Analysis Software: Your most cost-effective choice with superior ease-of-use This innovative software simplifies data analysis, and makes it easy to perform integration, reporting, and calibration functions. Integrated into the 7820A GC software keypad, advantages include: Data analysis based on methods created and saved on a computer Data analysis for up to two 7820A GCs Data analysis functions using only 5 screens Common integration parameters, easy-to-build calibration tables, and basic report options The software keypad allows you to create and save GC methods to the 7820A GC 6

THE UNCOMPROMISING PERFORMANCE YOU EXPECT FROM AN INDUSTRY LEADER The 7820A GC offers performance you can depend on for all your routine analyses: outstanding sensitivity, reproducibility, accuracy, and precision. Exactly what you look for and what you know you ll find in every Agilent analytical solution. FID analysis for aromatic solvent An easy-to-use, single-column method for aromatic solvent purity analysis meets the requirements of ten separate ASTM methods. EPC control and automatic injection ensure excellent repeatability for both retention time and peak area. In a single run, the wide dynamic response range of the flame ionization detector (FID) enables quantitative analysis of samples containing both very high and very low concentrations. Overlay of 10 runs demonstrates the 7820A system s outstanding repeatability. Hz 158 156 154 152 150 148 146 144 Trace pesticides in drinking water The high sensitivity of the micro-ecd ensures confident detection, easily meeting stringent requirements of international regulatory agencies. In addition, the micro-ecd s reduced susceptibility to contamination enables analyses in a variety of complex matrices. In this example, using nitrogen in place of helium as the carrier gas dramatically reduces cost per sample. 142 140 138 136 134 132 12 14 16 18 20 22 24 26 28 30 32 Min Chromatogram of 500 ppt organochlorine pesticides run on the Agilent 7820A GC with ECD. 7

Agilent J&W GC capillary columns and supplies: consistent performance and reliability You can be confident that Agilent J&W GC columns will provide a leak-free, inert flow path for optimal signal-to-noise performance. They are engineered to deliver the lowest column bleed, the highest column inertness, and the tightest column-to-column reproducibility. Agilent CrossLab combines the innovative laboratory services, software, and consumables competencies of Agilent Technologies and elevates service for the entire lab, delivering vital, actionable insights that drive improved economic, operational, and scientific outcomes. Learn more: www.agilent.com/chem/7820a Find an Agilent customer center in your country: www.agilent.com/chem/contactus U.S. and Canada 1-800-227-9770 agilent_inquiries@agilent.com Europe info_agilent@agilent.com Asia Pacific inquiry_lsca@agilent.com For research use only. Not for use in diagnostic procedures. This information is subject to change without notice. Agilent Technologies, Inc. 2016 Printed in the USA August 17, 2016 5991-1772ENCN