Paver and Ground lights - Anchor Plate

Similar documents
Inigo Console Table INSTALLATION INSTRUCTIONS P74300, P A Page 1 of 5

22.1 USED FOR: MATERIALS: all regular length 22 components stainless steel tool, silicon protective cover. DESCRIPTION

SpaVault TM Installation Guide for Bullfrog Spas (7-10 x 7-10 x 38 )

INSTALLATION INSTRUCTIONS FOR BALCO, INC. TRENCH AND ACCESS COVER TSA/ACA-X-250 W/O LINER FOR CAST-IN-PLACE INSTALLATION

FLO-THRU ACCESSORIES Above are some of the trench drain components typical to an installation. Double check your order to ensure that you have all com

10 EXTREME BASEMENT PANELS

1.52mm 1.52mm. Exterior Siding Sheet: Fabricated from Z275 steel material conforming to ASTM A653M grade 230 steel

4 EXTREME FOUNDATION PANELS

Underground Exhaust System

The professionals choice. Installation instructions Torridon. shower tray

PRODUCT INFORMATION Dero Hoop Rack

assembly and installation guide

4 EXTREME FOUNDATION PANELS

IMPORTANT: Levelness of the walk-in floor is critical. If the floor is not level, vertical panels cannot be aligned properly.

ZURN INDUSTRIES, INC., FLO-THRU DIV.,

Heartland Perma-Column 1841 E 1450 Rd. Lawrence, KS (785)

Infinity - Century Combination Installation Instructions Gelcoat & Solid Surface Bathware

INSTALLATION MANUAL IN-GROUND

36" CRESTONE FIRE RING

Residential Deck Safety, Construction and Repair. Juneau Permit Center, 4 th Floor Marine View Center,(907) February 2016

Universal frame fixing SXR-T

CRESTONE STRAIGHT FIRE PIT SKU:

INSTALLATION GUIDE PLEASE READ ENTIRE INSTRUCTION MANUAL BEFORE PROCEEDING!

FreeStyle Linear Drain with Full Mortar Bed Adapter Kit

PLEASE READ ENTIRE INSTRUCTION MANUAL BEFORE PROCEEDING!

F500 Steeplechase Waterjump with Valve Option

SINGLE BOWL VESSEL VANITY

Linear Drainage ZF806 ZF812

PRODUCT INFORMATION Dero Rolling Racks

LymTal International, Inc.

DRAINAGE SOLUTIONS SINCE 1908 SURFACE DRAINAGE. Installation Guide ARMTEC.COM

RUSTIC FIRE PIT SIENNA QUARRY GRAY TAN AUTUMN BLEND.

H50. DYNAMIC BARRIER Bench Fume Hood. Fume Hoods. Installation Instructions. 48"- 60"- 72"- 96" long

INSTALLATION MANUAL FOR WOOD ALUMINIUM GLAZED STRUCTURES. AILE COto

28 BELGIAN WEDGE FIRE RING

II TECHNICAL INSTALLATION GUIDE

FLOORING INSTALLATION INSTRUCTIONS

ACO DRAIN Site Installation Manual

Frame fixing SXS-F US

The high-performance frame fixing with SX-technology VERSIONS. zinc-plated steel stainless steel BUILDING MATERIALS

Rough-in frame and flush-mount panel installation instructions

Install & Maintenance Instructions

SECTION FLAT WALK-ON TYPE ALGAE CONTROL/LAUNDER COVERS

Precast Concrete Trench Drain Systems INSTALLATION INSTRUCTIONS

STORAGE AND TRANSPORTION

PHB TechBullet #8. Edge Restraints

INSTALLATION MANUAL. FOOTWALL/SINKWALL (floor mount)

MONUMENT SIGN INSTALL

H07 H09. BENCH FUME HOOD with Combination Sash. Fume Hoods. Installation Instructions. 48"- 60"- 72"- 96" long

INSTRUCTIONS FOR THE ASSEMBLY AND INSTALLATION OF THE VORTOX LIQUID SAMPLER

Claremont Fireplace Kit

Premier Outlast MicroShield Scratch-Resist Stainless Steel Undermount Kitchen Sink

Solar Powered TS1000 Installation Pictures. (Trench and Fill Method) City of Vallejo, CA

Linear Drainage Z886. Perma-Trench. Installation Instructions. 100mm Clear Opening

TABLE OF CONTENTS. 1.0 INTRODUCTION 1.1 Greenstone Structural Engineered Panels 1.2 Drawing and Element Numbers

EXOTIC WOOD DECKING INSTALLATION MANUAL

Above are some of the trench drain components typical to an installation. Double check your order to ensure that you have all components particular to

ASHWELL FIRE PIT SIENNA QUARRY GRAY TAN AUTUMN BLEND. Plan Date: June 2016

Short Form Guide Specification. Specifying Extruded Polystyrene Roof Insulation- STYROFOAM DECKMATE Plus Tapered

NATIONAL GYPSUM COMPANY 3-Hour Area Separation Wall System

TRUSSCORE PVC INTERLOCKING LINER PANEL

fermacell Powerpanel H 2 O Linear Shower Outlet 2.0

TREE GRATE (4x8) (DOWNTOWN AREA)

E-Spike All Stainless Steel Economy Bird Spikes Includes specifications for: E-Spike Full Row and Half Row Bird Spike Models.

SINGLE BOWL SEMI-RECESSED VANITY

Revision Date: April 01, Premier Vinyl Enclosure

ROOF MOUNT KIT OWNERS MANUAL

De Montfort Mark 7 Incinerator (Flatpack)

Zero-Radius Handmade Stainless Steel Kitchen Sinks (Pax and R0 PRO Series)

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

Proudly Made in the U.S.A. 5-Year Warranty. Wayfinding Products

(G) DOORS & WINDOWS LIST OF BUREAW OF INDIAN STANDARD CODE OF PRACTICE (ISI)

ROOF MOUNT KIT OWNERS MANUAL

MATHIS WALL-MOUNT FAUCET

Royal Corinthian, Inc. FRP COLUMN COVER INSTALLATION INSTRUCTIONS

Construction Specification for Utility Adjustments

Silva Cell. Silva Cell Two-Deep Installation Instructions. Helping Trees Live in the Urban Environment

SQUARE SUN TUNNEL INSTALLATION INSTRUCTION

Original Scandinavian rainwater system

SECTION INTERIOR STONE INTERIOR STONE

Installation Guide DURABLE, VERSATILE, ECONOMICAL

MODULAR ACOUSTIC FENCING INSTALLATION GUIDE

Special Applications. Dorn Equipment, Corporation 27 Upham Street Melrose, MA Phone: Fax:

138 H-STUD AREA SEPARATION WALL SYSTEM

TETON PATIO COVER INSTALLATION INSTRUCTIONS

SILVA CELL TWO-DEEP INSTALLATION INSTRUCTIONS HELPING TREES LIVE IN THE URBAN ENVIRONMENT

NATIONAL GYPSUM COMPANY 2-Hour Area Separation Wall System

ThermaSteel Corporation ASSEMBLY MANUAL

Prime Shower Enclosure & Base Kit

CW 3235 RENEWAL OF EXISTING MISCELLANEOUS CONCRETE SLABS TABLE OF CONTENTS

SPECIFICATIONS PORTER No PORTABLE BASKETBALL BACKSTOP SYSTEM (FOR INDOOR OR OUTDOOR USE) WITH FAN FIBERGLASS BACKBOARD

STANDARD DESIGN NOTES 1 / 2

TFX - Toggle Lock Installation Guide

EJOT frame anchor. Direct fastening of windows in masonry and concrete, without any anchors.

FASTENERS FOR EVERY TASK

INSTALLATION AND OPERATING INSTRUCTIONS

Multi-Piece Shower with Trench Drain

LINEAR DRAINAGE. Z886 Perma-Trench. 6" Perma-Trench Installation Instructions

FORM FOOTWALL. FORM FOOTWALL (floating) (floating) Installation Manual

EXIRA EXPOSED PIPE SHOWER INSTALLATION

Transcription:

Paver and Ground lights - Anchor Plate Meteor Ground and Paver lights come equipped with anti-theft Anchor Plate (Models: SH-130, SH-170, SH-180, SH-190, SH-220, SH-260, SH-270) or a set of anti-theft L-Bracket (Model: SH-230). The anti-theft Anchor Plate and L-Bracket not only deter theft, they also help prevent post-installation movement due to erosion or frost heaves. 1. Align holes on Anchor Plate to holes on bottom of Housing. Fasten Anchor Plate to Housing with provided screws. For SH-230, fasten L-Bracket to sides of housing. 2. Place assembled Housing with Anchor Plate in desired location. Refer to following video for installation instructions https://www.youtube.com/watch?v=njnwpkgvprc SH-130C/170C SH-180C SH-190C SH-220C SH-230C SH-260C/270C * SH-200 does not have Anchor Plate. 17 V1 Page 1 of 5

Stonework Surfaces Please be sure to consider how much sunlight the installation location receives before installing Meteor Solar LED fixtures. direct sunlight charge to operate at full capacity. 2 Step Installation Process To prevent damage to main units during construction process, Meteor Housing and Anchor plate can be installed first. When construction is complete, remove Styrofoam filler so Main Units can be installed. *Note: Meteor fixtures cannot be installed without Housing Step 1 Step 2 Before installing Housing with Anchor Plate in final location, make sure adjacent stones have been cut and placed properly. Add or remove bedding sand beneath Housing to ensure top of Housing is flush with stonework surface. Remove foam from Housing. Install Main Unit. Fasten stainless steel rim to housing with provided anti-theft screws. 17 V1 Page 2 of 5

New Construction - Concrete Pour Please be sure to consider how much sunlight the installation location receives before installing Meteor Solar LED fixtures. direct sunlight charge to operate at full capacity. 2 Step Installation Process For concrete pour, Meteor Housing and Anchor Plate can be installed first without main fixture. Housing comes with Styrofoam filler. When construction is complete, remove Styrofoam filler. Install Main Units. Refer to following video for installation instructions https://www.youtube.com/watch?v=njnwpkgvprc Step 1 Step 2 Confirm Housing and Anchor plate are positioned at the correct location. Housing and Anchor Plate must be fixed in position or they will shift during concrete pour. Please make sure Styrofoam filler stays in Housing during concrete pour. Make sure top of Housing is flush with concrete surface. Make adjustments as needed. Step 3 FLUSH WITH TOP OF CONCRETE After construction is finished, remove Styrofoam filler. Install Main Units. Secure rim to housing with provided anti-theft screws. 17 V1 Page 3 of 5

Wooden Surface (SH-220) Please be sure to consider how much sunlight the installation location receives before installing Meteor Solar LED fixtures. Silicone Sealants * Step 1 Mark and cut two-tiered hole into the wood for Housing. First, trace and cut hole to fit the base of the Housing, NOT top circumference of Housing. Step 2 Counterbore hole with dimensions of top circumference of Housing. Depth to match thickness of upper lip on Housing so fixture sits flush with wooden surface. *Recommendation: Down Corning 737 Step 3 Fasten Main Unit to housing with provided anti-theft screws. 17 V1 Page 4 of 5

Existing Concrete and Asphalt (SH-200) Please be sure to consider how much sunlight the installation location receives before installing Meteor Solar LED fixtures. Step 1 Mark area where light will be installed. Step 2 Use concrete core drill to bore hole in desired location. Drill 2.2 deep so top of housing will be flush with surface. If hole is too deep, pad with bedding sand. Silicone Sealants* Step 3 Step 4 Apply sealant along inside edge of hole. *Recommendation: Down Corning 737 Lower SH-200 into hole and push down until rim is flush with surface. Refer to following video for installation instructions https://www.youtube.com/watch?v=puzcr7mcpwi 17 V1 Page 5 of 5