LISTING INFORMATION OF Fox Block Insulating Concrete Forms (Fox Block ICFs) SPEC ID: 32745

Similar documents
(800) (562) A Subsidiary of the International Code Council

LISTING INFORMATION OF International Beams - IB Series Joists SPEC ID: 27316

Sept 30, 2004 Page 1 PRODUCT DESCRIPTION PRODUCT FEATURES

LISTING INFORMATION OF Metl-Span, LLC THERMALSAFE 8" Thick 3 Hour Fire Rated Panels SPEC ID: 29868

Advantage ICF System Product Information Bulletin

LISTING INFORMATION OF Metl-Span, LLC THERMALSAFE 4" Thick 1 Hour Fire Rated Wall Panels SPEC ID: 29555

SECTION PERMANENT FORMS Insulating Concrete Forms Rev

LISTING INFORMATION OF ClarkDietrich Wall Assembly Design No. CD/WA SPEC ID: 26053

LISTING INFORMATION OF Epilay - Superior, Ultra and Platinum Roofing Underlayments SPEC ID: Epilay Inc S. Main Street, E1 unit C

LISTING INFORMATION OF Dryvit - Category 2 OUTSULATION NC EIFS Wall Systems SPEC ID: 29344

SECTION INSULATING CONCRETE FORMING (ICF)

Product Information Bulletin

The Perfect Block OEM ICC Equivalent Product Compliance Report

LISTING INFORMATION OF Dryvit - Category 1 OUTSULATION EIFS Wall Systems SPEC ID: 29311

Insulated Concrete Forms (ICFs)

LISTING INFORMATION OF CCI Manufacturing Inc. - HiBAR SPEC ID: CCI Manufacturing Inc Ave. Edmonton, AB T5V 1K5 Canada

LISTING INFORMATION OF International Fireproof Technology Inc. - Joint Systems SPEC ID: 43848

ICC-ES Evaluation Report Reissued September 1, 2010 This report is subject to renewal in two years.

Section 1 - Introduction 1.1 Introduction Welcome to Fox Blocks. You have made an excellent decision to use Fox Blocks Insulated Concrete Forms (ICFs)

LISTING INFORMATION OF ClarkDietrich Steel 'H' Stud and 'U' Track Fire-resistance-rated Area Separation Wall Assemblies SPEC ID: 26662

Arxx High Performance Wallsystems

LISTING INFORMATION OF Metl-Span, LLC THERMALSAFE 6" Thick 2-hour Fire Rated Panels SPEC ID: 29771

Code Compliance Research Report CCRR-1060

DIVISION: CONCRETE SECTION: INSULATING CONCRETE FORMING REPORT HOLDER: AMVIC INCORPORATED

ESR ICC Evaluation Service, Inc. Issued June 1, 2005 This report is subject to re-examination in one year.

LISTING INFORMATION OF Mitek Design No. MCI/WI SPEC ID: MiTek Canada, Inc. 100 Industrial Road Bradford, ON L3Z 3G7 Canada

LISTING INFORMATION OF SIPA - Structural Insulated Panels (SIPs) SPEC ID: Structural Insulated Panel Association (SIPA) P.O.

Code Compliance Research Report CCRR-0228

Code Compliance Research Report CCRR-0164

DIVISION: CONCRETE SECTION: INSULATING CONCRETE FORMING REPORT HOLDER: DIVERSIFOAM PRODUCTS EVALUATION SUBJECT:

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California

Issue Date: April 2003 Release: I. Product Specifications

High Performance Insulating Concrete Form

DIVISION: CONCRETE SECTION: INSULATING CONCRETE FORMING REPORT HOLDER: NUDURA CORPORATION EVALUATION SUBJECT:

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

SECTION PERMANENT FORMS - INSULATING CONCRETE FORMS Page 1 of 7

DS131 EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

ICC ES SYSTEM SYSTEM. Trusted DIVISION: 07 SECTION: AND FINISH REPORT HOLDER: ICC-ES Evaluation. Reissued 08/2016.

DIVISION: CONCRETE SECTION: INSULATING CONCRETE FORMING REPORT HOLDER: SUPERFORM PRODUCTS LTD. EVALUATION SUBJECT:

Code Compliance Research Report CCRR-0234

Polystyrene beads designated Neopor F5 Pro, F2200, F2300, F2400, F5300, F5300 Plus, F5200 Plus, KF2200, KF2300, KF2300S, KF2400

Code Compliance Research Report CCRR 0270

SECTION STAY-IN-PLACE INSULATED CONCRETE FORMING SYSTEM

Code Compliance Research Report CCRR 0241

October 12, Yours very truly, Gary G. Nichols, P.E., SECB Vice President. GGN/md Enclosure Evaluation Committee

UNIFIED FACILITIES GUIDE SPECIFICATIONS

MID-RISE DESIGN & CONSTRUCTION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: FOUR SEASONS BUILDING PRODUCTS, LLC

Code Compliance Research Report CCRR-0266

Code Compliance Research Report CCRR-0185

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

Code Compliance Research Report CCRR-0231

DRAFT - MOCA STANDARD for Fiber-Reinforced Magnesium Cement Board

Gold Bond BRAND Gypsum Sheathing

Polycrete Big Block Standard Specification

Code Compliance Research Report CCRR-0213

Code Compliance Research Report CCRR-0213

TYPICAL ENGINEERED COMMERCIAL / RESIDENTIAL DETAILS & TABLES

Code Compliance Research Report CCRR-0118

REPORT NUMBER: COQ-001 ORIGINAL ISSUE DATE: June 27, 2013 EVALUATION CENTER

REPORT NUMBER: COQ-003 ORIGINAL ISSUE DATE: July 19, 2013

Welcome. Integra Products

Code Compliance Research Report CCRR-0238

Steady-State R-Value Calculation. PS-4600 PolySteel Form

SECTION THERMAL INSULATION

Code Compliance Research Report CCRR-0223

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

I-STUD Shaftwall System

LISTING INFORMATION OF Weyerhaeuser - TJI Joists SPEC ID: 26948

The Advantage ICF System. Installation Detail Drawings. The Advantage ICF System. Recommendation: Review the Advantage ICF System Installation Videos.

PRODUCTION SPECIFICATIONS INSULATED CONCRETE FORMS

PRODUCTION SPECIFICATIONS INSULATED CONCRETE FORMS

Metal Roof Certification & Listing Program. 1. Program Licensee: This Certification Report was used to qualify Florida Product Approval FL

Code Compliance Research Report CCRR-0194

Code Compliance Research Report CCRR-0238

DIVISION: CONCRETE SECTION: SPECIALTY PLACED CONCRETE REPORT HOLDER: EMMEDUE S.P.A.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

Code Compliance Research Report CCRR-0106

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079") WET FILM ± 7.5 ± 5

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

Code Compliance Research Report CCRR-0257

Metal Roof Certification & Listing Program. 4. Evaluated Roof System Description: 1. Program Licensee: 2. Certified Roof Covering: 5.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: TRESPA NORTH AMERICA, LTD.

Metal Roof Certification & Listing Program

TER No Attachment of Exterior Wall Coverings Through Kingspan GreenGuard Extruded Polystyrene (XPS) Sheathing to Wood or Steel Wall Framing

SECTION FIBERGLASS SANDWICH PANEL ASSEMBLIES

USG Co. Plant # th Street Mediapolis, IA Atlantic Wallboard Ltd. # Jervis Lane St. John, NB E2J 0A9

INSTALLATION CHECKLIST 2 ND EDITION. Fox Blocks Abbott Drive Omaha, NE

Specification Document

TECHNICAL EVALUATION REPORT No. 27/2008/2060

RENDERED TO. CastleRock Building Products Incorporated P.O. Box 1258 Meridian, ID USA 83680

REPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION

The better way to build TM. Installation Manual NAILBASE PANELS

TEST REPORT. Report No.: H Rendered to: GEORGIA-PACIFIC WOOD PRODUCTS, LLC Atlanta, Georgia

Code Compliance Research Report CCRR-0153

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

REPORT HOLDER: OMEGA PRODUCTS INTERNATIONAL, INC CALIFORNIA AVENUE CORONA, CALIFORNIA EVALUATION SUBJECT:

ESR-1794* Reissued September 1, 2012 This report is subject to renewal November 1, 2014.

PART 1 GENERAL RELATED SECTIONS A. Section 03200: Concrete Reinforcement. B. Section 03300: Cast-In-Place Concrete.

Beginning of the Course

Transcription:

LISTING INFORMATION OF Fox Block Insulating Concrete Forms (Fox Block ICFs) SPEC ID: 32745 Fox Blocks, a Division of Airlite Plastics Co. 6110 Abbott Drive Omaha, NE 68110-2805 This report is for the exclusive use of Intertek s Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Fox Blocks, a Division of Airlite Plastics Co. 32745 Rev: Jan 20 2016 12:03PM Uncontrolled Copy Page 1 of 8

Fox Block ICFs are Insulated Concrete Form (ICF) systems that are formed of expanded polystyrene with polypropylene plastic cross-ties. Fox Block ICFs are pre-assembled ICF forms with a reversible, interlocking connection design. The systems are available in the following sizes and configurations: 4" Straight 4" 90 Corner 4" 45 Corner 6" Straight 6" 90 Corner 6" 45 Corner 6" Corbel Ledge 6" Taper Top 6" T-Block (Short) 6" T-Block (Long) 6" Radius Blocks (5',6',7',8',9' &10') 8" Straight 8" 90 Corner 8" 45 Corner 8" Corbel Ledge 8" Taper Top 8" T-Block (Short) 8" T-Block (Long) 8" Curb Block 10" Straight 10" 90 Corner 12" Straight 12" 90 Corner RATINGS Product/AssemblyStandard ASTM E119 CAN/ULC S101 Rating (if applicable) Design no. FXB/ICF 240-01 Fox Block ICFs ASTM E2634, including: ASTM C578 (EPS) ASTM D635 (cross-tie) ASTM D638 (cross-tie) ASTM D732 (cross-tie) ASTM D1761 (cross-tie) ASTM D1929 (cross-tie) ASTM E84 (EPS) UL 1715 (ICF) ICC-ES AC353 Type II EPS CC1 classification Min. tensile strength: 32.3 kn/m 2 (675 lb/ft 2 ) Min. shear strength: 3080 psi Refer to Table 2 of IRR-1010 Min. Ignition Temp. 350 C (662 F) FS 25, SD 450 Meets ASTM E2634 Section 6.3.1 IRR-1010 Fox Blocks, a Division of Airlite Plastics Co. 32745 Rev: Jan 20 2016 12:03PM Uncontrolled Copy Page 2 of 8

ASTM E283 (4 ICF) Max air infiltration 0.02 cfm/ft 2 No water leakage after 2 hours; ASTM E331 (4 ICF) 15 psf pressure differential CAN/ULC S717.1, including: CAN/ULC S701 (EPS) ASTM D635 (cross-tie) ASTM D638 (cross-tie) ASTM D732 (cross-tie) ASTM D1761 (cross-tie) ASTM D1929 (cross-tie) Type 2 EPS CC1 classification Min. tensile strength: 32.3 kn/m 2 (675 lb/ft 2 ) Min. shear strength: 3080 psi Refer to Table 2 of IRR-1010 Min. Ignition Temp. 350 C (662 F) MANUFACTURING LOCATIONS The following facilities are certified to manufacture Fox Block ICFs that comply with the ratings described in IRR- 1010 and the table in the section above. Airlite Plastics Co. 525 Kansas Avenue Omaha, NE 68110 Poly Foam Corporation 2355 Providence Road PO Box 906 Northbridge, MA 01534 FMI-EPS, LLC (Post Falls) 9456 N McGuire Road Post Falls, ID 83854 FMI-EPS, LLC (Jerome) 280 Rose Street Jerome, ID 83338 Modern Polymers Inc LLC 901 West Academy Cherryville, NC 28021 Airlite Plastics Co. 2860 Bath Pike Nazareth, PA 18064 Tegrant Diversified Brands 1100 Garden of the Gods Rd Colorado Springs, CO 80907 Cellofoam NA Inc. 11237 Astronaut Blvd Orlando, FL 32837 Polymos Inc. 3333 F.X. Tessier, Vaudreuil-Dorion, QC J7V 5V5 Canada Diversified Plastics Corp. 108 W Mt. Vernon St. Nixa, MO 65714 Fox Blocks, a Division of Airlite Plastics Co. 32745 Rev: Jan 20 2016 12:03PM Uncontrolled Copy Page 3 of 8

Schaumaplast Foam Molders LP 21 N.39 th Avenue Phoenix, AZ 85009 Insulfoam 628 Western Drive Anchorage, AK 99501 Downeast Plastics Ltd. 2598 Chemin Acadie Road Cap-Pele, NB E4N 1E3 Canada Foam Fabricators, Inc. 900 E. Parkway Keller, TX 76248 EFP Corp. 233 Middleton Run Rd. Elkhart, IN 46516 HW Manufacturing Inc. Mile Ten Road Starbuck, MB R0G 2P0 Canada Plymouth Foam Inc. 13900 Industry Ave. Becker, MN 55308 APTCO LLC 31381 Pond Road MacFarland, CA 93250 EFP Corp. 1102 Brooks St. SE Decatur, AL 35601 The following facilities are under Intertek inspection for the quality control of the Fox Blocks Cross-Ties: Airlite Plastics Co. 6110 Abbot Drive Omaha, NE 68110 Airlite Plastics Co. 2860 Bath Pike Nazareth, PA 18064 Attribute Value Code Reports Yes Criteria CAN / ULC S701 (2005) Criteria ASTM E283 (2004) Criteria CAN / ULC S101 (2007) Criteria ASTM C578 (2008) Criteria ICC-ES AC353 (2007) Criteria ASTM E331 (2009) Fox Blocks, a Division of Airlite Plastics Co. 32745 Rev: Jan 20 2016 12:03PM Uncontrolled Copy Page 4 of 8

Criteria ASTM C578 (2009e1) Criteria ASTM E119 (2010) Criteria CAN / ULC S701 (2011) Criteria ASTM C578 (2010a) Criteria ASTM C578 (2011) Criteria ASTM C578 (2012) Criteria CAN/ULC S717.1 (2012) Criteria ASTM E2634 (2011) CSI Code 03 10 00 Concrete Forming and Accessories Intertek Services Certification Listed or Inspected LISTED Listing Section CONCRETE FORMS 3103050; 3103255; 3114608; 3182745; 3186516; 3193147; 3193149; 100061415; 100146783; 100155912; 100412773; 100546682; 100675099COQ; 100756430MID; Report Number 100955609COQ; 100749979COQ; 101217382COQ; 101240281COQ; 101259075COQ; 101463741COQ; 101539455COQ; 101568946COQ; 101571230TOR; 101571239COQ; 101624180COQ; 101680922COQ; 101757474COQ, 101766167COQ, 101766276COQ Spec ID 32745 Fox Blocks, a Division of Airlite Plastics Co. 32745 Rev: Jan 20 2016 12:03PM Uncontrolled Copy Page 5 of 8

DRAWING INDEX FXB/ICF 240-01 Fox Blocks, a Division of Airlite Plastics Co. 32745 Rev: Jan 20 2016 12:03PM Uncontrolled Copy Page 6 of 8

FXB/ICF 240-01 Division 03 Concrete 03 11 00 Concrete Forming 03 11 19 Insulating Concrete Forming Page 1 of 2 Design Number FXB/ICF 240-01 FOX BLOCK INSULATED CONCRETE FORMS Fox Blocks, a Division of Airlite Plastics Co. ASTM E119-11a ULC / CAN S101-07 Fire Rating Only - Load Rating Not Within The Scope Of This Listing Assembly Rating 2, 3 and 4 hours FORMED WALL THICKNESS MAX FIRE RATING 4 in. (102 mm) 2 Hour 6 in. (152 mm) 4 Hour 8 in. (203 mm) 4 Hour 10 in. (254 mm) 4 Hour 12 in. (305 mm) 4 Hour 1. CONCRETE: Pour normal weight concrete (density typically between 145-155 pcf) having a minimum 21 MPa (3,000 psi) nominal compressive strength into the forming system (Item 2). 2. CERTIFIED MANUFACTURER: Airlite Plastics Co. CERTIFIED PRODUCT: Fox Block Insulated Concrete Forms (ICF) FORMING SYSTEM: The Fox Block ICF forming system consists of Type 2 (CAN/ULC S701) or Type II (ASTM C578) molded expanded polystyrene (EPS) foam panels with embedded polypropylene ties that come Date Revised: June 26, 2013 Project No: 100546682 Fox Blocks, a Division of Airlite Plastics Co. 32745 Rev: Jan 20 2016 12:03PM Uncontrolled Copy Page 7 of 8

FXB/ICF 240-01 (page 2 of 2) Division 03 Concrete 03 11 00 Concrete Forming 03 11 19 Insulating Concrete Forming Page 2 of 2 preassembled as blocks and are produced in nominal concrete core widths of 4 in. (102 mm), 6 in. (152 mm), 8 in. (203 mm), 10 in. (254 mm), and 12 in. (305 mm) widths. The Fox Block ICFs are produced in 48 in. length x 16 in. height (1220 mm x 410 mm) for all core thicknesses. All Fox Block ICF products have an EPS panel thickness of 2-5/8 in. (66.7 mm). The top and bottom of the EPS panels have an interlocking system which aligns the forms together as they are stacked together. Fox Block ICF systems have polypropylene ties spaced at 8 in. (203 mm) on center (oc) in the cavity of the ICF that include flanges acting as furring strips for mechanical fastening. 3. SHEATHING AND EXTERIOR FINISHES (OPTIONAL): Not required for the fire resistance ratings described in this listing. An approved thermal barrier may be installed subject to the requirements of the applicable Building Code. When desired, exterior finishes may be applied to the exterior side of the forming system (Item 2) wall assembly without diminishing the assembly rating. Exterior Insulation Finish System (EIFS), any exterior stucco, brick or brick veneer, stone or stone veneer, cultured stone and siding made from vinyl, aluminum, wood, or steel may be used. Apply exterior finishes in accordance with the manufacturer's instructions. 4. POLYPROPYLENE FORM TIES: Each 48 in. (1220 mm) of length, Fox Block ICF have six polypropylene ties. The polypropylene ties are spaced nominally 8 in. (203 mm) oc. The polypropylene ties are open to allow concrete to flow easily, and to allow seating for the placement of horizontal and vertical rebar placement. 5. STEEL REINFORCEMENT: Place the steel reinforcement before filling the forming system with concrete (Item 1). The rebar used is to be designed and placed per the applicable code requirements and approved by a registered design professional with the appropriate license for the Authority Having Jurisdiction. 6. WALL ASSEMBLY: The Fox Block ICF wall assembly may be used as either an interior or exterior wall. ICFs exposed to the interior of a building shall have a thermal barrier (item 3) attached. Exterior walls are only required to have a thermal barrier on the side facing the interior of the building. The fire resistance rating is applicable to the Fox Block ICF wall assembly from either side. Date Revised: June 26, 2013 Project No: 100546682 Fox Blocks, a Division of Airlite Plastics Co. 32745 Rev: Jan 20 2016 12:03PM Uncontrolled Copy Page 8 of 8