Modelling a grid connected Photovoltaic system with an aerogenerator through labview

Similar documents
Monitoring, modelling and simulation of PV systems using LabVIEW

Estimation and monitoring of grid connected PV system generation

USE OF PV PLANTS MONITORING TO CHARACTERIZE PV ARRAYS POWER

Journal of American Science 2014;10(8) Software Design of Photovoltaic Grid-Connected Power Plants

A study for an optimization of a hybrid renewable energy system as a part of decentralized power supply

ME590 Report (2013 winter)

Modelling Photovoltaic Systems using PSpice

ANN-Based Sizing of Battery Storage in a StandAlone PV System

Design and Simulation of Photovoltaic System in Matlab using Simulink

Applied Energy 86 (2009) Contents lists available at ScienceDirect. Applied Energy. journal homepage:

Grid-connected photovoltaic module and array sizing based on an iterative approach

Solar cell junction temperature measurement of PV module

PV DOMESTIC HOT WATER SYSTEM

Steady-State and Dynamic Study of Photovoltaic (PV) System in University of New Haven: Towards to a Green and Secure Campus

Performance evaluation of hybrid solar parabolic trough concentrator systems in Hong Kong

Investigating the Shading Impact of Rail on the Energy Output of a PV System in Hong Kong

Design of Enhanced MPPT Techniques for Solar and Wind Energy Conversion Systems in a Microgrid

A Distributed Maximum Power Point Control For Efficiency Enhancement Of Photovoltaic System

A technique for accurate energy yields prediction of photovoltaic system

Design and Development of a GUI for an Optimal Hybrid Energy System

AUTOMATIC DETECTION OF PV SYSTEM CONFIGURATION

Fuzzy Logic Controller Based Maximum Power Point Tracking for PV panel using Boost Converter

Testing of a Predictive Control Strategy for Balancing Renewable Sources in a Microgrid

Bringing Renewable Energy to the Electrical Engineering Undergraduate Education and Research at UPRM

A Performance Model for Bifacial PV Modules

Solar Photovoltaic Electric System Protection. Prof. Brian Norton Dr. Sarah McCormack Mr. Kevin O Farrell. Ayda Esfandyari 28/02/2014

The Impact of Irradiance Time Behaviors on Inverter Sizing and Design

Mathematical Modeling of Solar PV Panels

Establishment of Output Models and Constraints Analysis for Independent Wind/PV/Storage System

International Journal of Applied Science and Technology Vol. 2 No. 3; March 2012

Garg Vishakha, International Journal of Advance Research, Ideas and Innovations in Technology.

Measured Versus Predicted Performance of Building Integrated Photovoltaics

TERRA NOVA Wind + Solar Energy Premium Kit

Operation and performance of grid-connected solar photovoltaic power system in Kocaeli university

Integrated Solar PV and Thermoelectric Energy System

Levy Senior Center Solar Panel Installation RFP # ADDENDUM No. 1

Webpage: Volume 6, Issue VI, July 2018 eissn

Micro-generation using LMS Imagine.Lab AMESim

DESIGN AND SIMULATION OF GRID-CONNECTED PV SYSTEMS WITH GENERATION OF CONSTANT POWER USING FUZZY LOGIC CONTROLLER

Solar PV Performance and New Technologies in Northern Latitude Regions

Design and Simulink of Intelligent Solar Energy Improvement with PV Module

Modeling and Simulation of a Solar Photovoltaic System, Its Dynamics and Transient Characteristics in LABVIEW

THE EFFECT OF SOILING ON LARGE GRID CONNECTED PHOTOVOLTAIC SYSTEMS IN CALIFORNIA AND THE SOUTHWEST REGION OF THE UNITED STATES

INACCURACIES OF INPUT DATA RELEVANT FOR PV YIELD PREDICTION

A Novel Power Output Model for Photovoltaic Systems

6KW Grid Interactive Photovoltaic System

Performance analysis of PV panel under varying surface temperature

Kinetic and Solar energy

MODELING AND SIMULATION OF RENEWABLE HYBRID POWER SYSTEM USING MATLAB/SIMULINK ENVIRONMENT

Reference: Photovoltaic Systems, p. 229

Design and Performance Analysis of a Grid Connected Solar Photovoltaic System

Performance loss rates of grid-connected photovoltaic technologies in warm climates

A SIZING TOOL FOR PV STANDALONE SYSTEM

Investigation on Temperature Coefficients of Three Types Photovoltaic Module Technologies under Thailand Operating Condition

PV Emulator. Denis Pelin. Jelena Jukić Antolović. Vjekoslav Rapčan. Case Study

NEW COURSE DEVELOPMENT OR EXISTING COURSE ASSESSMENT REPORT

Australian Journal of Basic and Applied Sciences. Hybrid Control Method for Maximum Power Point Tracking (MPPT) of Solar PV Power Generating System

A Novel Intelligent Fuzzy Controller for MPPT in Grid-connected Photovoltaic Systems

A statistical-based approach for fault detection and diagnosis in a photovoltaic system

Volume 10 - Number 17 - May 2014 (19-25) Effect of Tilt Angle Orientation on Photovoltaic Module Performance. Salih Mohammed Salih, Laith Awda Kadim

Modeling and Simulation of Solar and Wind Hybrid Power System Using Matlab

Study on Load Profiling and Energy Management Systems

Electrical/thermal performance of hybrid PV/T system in Sharjah, UAE

Impact Study on Power Generation from Photovoltaic System due to Change in Local Irradiance and Temperature at Kathmandu Valley, Nepal

AGENDA. I. Photovoltaics Basics: What is really going on in a Solar Cell?

Performance Analysis of grid connected PV Wind Hybrid Power System

The Impact of Grid Connected Photovoltaic Generation System to Voltage Rise in Low Voltage Network

INVESTMENT PROPOSAL ON THE FORMER LANDFILL IN SCHISTO AREA - MUNICIPALITY OF PERAMA

Quality Assessment of PV systems by Analysis of System Performance

Microgrid Energy Management System Using Fuzzy Logic Control

This is an electronic reprint of the original article. This reprint may differ from the original in pagination and typographic detail.

SOLAR MODULES FOR ROOFTOP SYSTEMS AND SOLAR PARKS ENGLISH

Design of a Multiparameter Acquisition System for Photovoltaic Panels

PERFORMANCE OF BP SOLAR TANDEM JUNCTION AMORPHOUS SILICON MODULES

KEYWORDS: Renewable energy system, Hybrid,Rural electrification, PV, Wind

Solar Energy Modeling for Residential Applications

DESIGN AND TECHNICAL ANALYSIS OF HYBRID RENEWABLE ENERGY SYSTEM WITH HOMER SOFTWARE. K L University, Vaddeswaram, Guntur (Dt), Andhra Pradesh, India

The Master of IEEE Projects. LeMenizInfotech. 36, 100 Feet Road, Natesan Nagar, Near Indira Gandhi Statue, Pondicherry

Design and Implementation of Grid Connected Hybrid PV and Wind Energy Generation System

Development of a Smart Grid Simulation Environment 1

PV*SOL. The future is here. Simulation programs from Valentin Software. New: PV*SOL advanced

Shunt Active Power Filter Wind Energy Conversion System

Quality Control Applied to the Photovoltaic Systems of the Galapagos Islands: The Case of Baltra and Santa Cruz. Andrea Alejandra Eras Almeida

PVS - Photovoltaic Systems

PVSST 1.0 sizing and simulation tool for PV systems

Laboratory experience in power engineering at the University of Queensland

Ali Bashiri, Pooya Najafi, Sasan Hosseinalizadeh and Mojgan Bashiri

SIMSCAPE Model of Solar PV Cell with Partial

The Challenges of Accurately Predicting PV System Performance

Photovoltaic Efficiency of a Grid Connected 10 kwp System Implemented in the Brasov Area

THE ZERO ENERGY POOL SOLAR ELECTRICITY + POOL HEATING NATIONAL

IN-GRID SOLAR-TO-ELECTRICAL ENERGY CONVERSION SYSTEM MODELING AND TESTING

University of Strathclyde Faculty of Engineering

Fault Management in Renewable Energy Resources

PhD Dissertation Defense Presentation

A Comparison of Perturb & Observe and Fuzzy-Logic Based MPPT Methods for Uniform Environment Conditions

Application of IEC Standards to Analyze PV System Performance in Different Climates

Off-Grid Hybrid Energy System Incorporating Renewable Energy: The Case of Remote Coastal Area of Bangladesh

Analysis of mismatch and shading effects in a photovoltaic array using different technologies

Grid-connected photovoltaic (PV) systems with batteries storage as solution to electrical grid outages in Burkina Faso

Transcription:

Modelling a grid connected Photovoltaic system with an aerogenerator through labview 1 B. Taghezouit*, K. Abdeladim*, A. Hadj Arab*, A. Chouder** and S. Bouchakour* *CDER, Algiers, Algeria, E-mail : 1 bi.taghezouit@cder.dz **Université de M Sila, Algeria Abstract In this paper, we propose a methodology based on virtual instrumentation in order to model a grid connected PV system of the Centre de Développement des Energies Renouvelables (CDER), Algiers, which is running since 2004, a wind energy system was also considered for the study. Note that this task was achieved under LabVIEW environment. It can be seen that dataacquisition systems are widely used in renewable energy source (RES) applications in order to collect data regarding the installed system (radiometric and electrical), for evaluation purposes. Therefore, a datalogger (Agilent 34970 A) was setup in order to monitor the whole installation, in view to evaluate its performance. Our system is able to store and display both PV plant electrical output measurements and collected variables environmental data. Performance of the PV system are then evaluated and displayed through an attractive and convivial user-interface. The first part of this work concerns the extraction of electrical and radiometric data in text format file, already measured with a data acquisition; afterwards implementing model including PV system connected to the grid and the wind generator equations under LabVIEW The second part of the work is devoted to the development of a graphical program that evaluates the energy balance, the performance of the PV system. This program will allow us to create a user-friendly interface with all useful information, leading to a creation of a database. Keywords Meteorological Data, LabVIEW; Measurements, Virtual Instrument, Database; PV System, Monitoring I. INTRODUCTION The analysis of data including their monitoring and treatment has become more friendly, flexible and attractive with the development of modern instruments and testing technology such as LabVIEW (Laboratory Virtual Instrument Engineering Workbench). LabVIEW is a graphical programming language by National Instruments that uses icons instead of lines of text to create applications. It should be noted that several laboratories use this kind of technology since it offers several advantages. Therefore, the conception of virtual instruments has become a popular program tool for test and measurement domain, in particular for photovoltaic (PV) systems. The aim of this work is to evaluate the performance of the grid connected system installed at the level of the CDER, using LabVIEW platform. Many applications of LabVIEW for monitoring PV systems have been reported before in the literature [1-5]. In this paper, a description will be given for each step leading us for the design of such program. Our task is to monitor data which are needed in order to calculate the different characteristics of the installation such as different yields and other parameters. In this study, we put emphasis on how to develop a friendly interface, which includes all information gathered from the PV system. In the same interface, another part is dedicated to the results obtained from simulations we have performed using the called platform. II. EXPERIMENTAL DETAILS A. Wind energy modelling A precise determination of the mean wind speed is crucial for the evaluation of the wind potential, since this last depends on the cube of the mean wind speed. 1) Weibull distribution In order to calculate the mean power from a wind turbine over a range of mean wind speeds, a statistical expression which gives a good fit to wind data known as the Weibull distribution was used. In non-dimensional form, this can be written as: (1) v: is the wind speed, k is the shape factor and c is the scale factor. The mean wind velocity can be obtained by the expression: (2) Also, the available power in the wind can be expressed as: Where is the air density, equal to 1,225 kg/m 3. B. PV system modelling (3) The objective of the simulation of the grid connected PV system is to obtain expected evolution of voltages and currents at the DC side of the system as well as at the AC side and at the inverter output. Therefore, 68

simulation results will give the expected behaviour, in a dynamic way of the whole system taking into account real climatic conditions. The simulation of the whole grid connected PV system is based on the models presented below for both PV modules and for the inverter and is carried out in LabVIEW environment. The flowchart of the simulation process is illustrated in figure 1. E i is the effective solar irradiation in W/m² with nominal effective solar irradiance E in = 1000W/m². TCv is the temperature coefficient of V oc in V/ C. TCi is the temperature coefficient of I sc in A/ C. The variable s is the number of PV panels with the same electrical characteristics connected in series and p is the number of PV panels with the same electrical characteristics connected in parallel. TABLEAU I CHARACTERISTICS OF THE PV MODULE Fig.1: Simulation process 1) Photovoltaic module modelling The model proposed [7-8] was used. It s takes into consideration the manufacturer data sheet, the air temperature, and the irradiation value, it s possible to model the generation system for a photovoltaic installation. It is expected that this model will be used for future applications in the area of power systems where most of the existing models cannot be used to calculate power flow, harmonic analysis, optimal load for maximization of the power, etc. The current - voltage relationship is given by: (4) The model includes a short circuit current I sc_x at any solar irradiance and temperature conditions, an open circuit voltage V oc_x at any solar irradiance and temperature condition and an I-V characteristic constant b which is defined between 0.01 and 0.18, where smaller is the b, greater is the produced power. I sc_x and V oc x can be obtained using equations: (5) (6) I sc_ref and V oc_ref are the short circuit current and open circuit voltage at Standard Test Conditions (25 C and 1000W/m²) respectively. V oc_max is the open-circuit voltage at 25 C and more than 1200W/m² (slightly superior to V oc_ref ). T cell is the solar cell temperature in C with nominal temperature T n = 25 C. Physical Characteristics dimensions Weight number of cells in series 36 number of cells in parallels 2 TONC (800 W/m², 20 c, am 1.5, 1m/s) Electrical Characteristics 1 310*654*39,5 mm 11,5 kg 47 C Standard Test Conditions : 1000 W/m 2, 25 ºC, AM=1,5 I sc_ref [A] 6.54 V oc_ref [V] 21.6 I mpp_ref [A] 6.03 V mpp_ref [V] 17.6 The PV panel characteristic constant is b = 0,098, which was calculated using the Fixed Point Theorem (6) and STC parameters (table 1). The variable ε is the maximum allowed error to stop the iteration. While: (7) Using Linear Reoriented Coordinates Method (LRCM) [9-10], the current and voltage equations at the maximum power point (MPP) are given as follows: 2) Inverter model (8) (9) The following equations define the behavioural model developed by Sandia National Laboratories [11,12]. As independent variables, the both DC power and DC voltage are used to calculate the inverter AC power. The parameters with the o subscript are constant values that define a reference or nominal operating condition. (10) 69

Where: (11) (12) (13) The values of performance parameters given by recognized testing laboratory (SANDIA, CEC, Spec ) are shown in table II [13-1]. TABLEAU II INVERTER PERFORMANCE PARAMETER, SANDIA NATIONAL LABORATORIES DATABASE Parameters of inverter model maximum AC-power at reference 2700 operating condition, P aco [W] DC-power level at which the AC-power is achieved at the reference operating 2879 condition P dco [W] DC-voltage level at which the AC-power is achieved at the reference operating 277 condition V dco [V] self-consumption by inverter, P so [W] 27.9 Constant parameters of inverter model C 0 [1/W] -1.009e-5 C 1 [1/V] -1.367e-5 C 2 [1/V] -3.587e-5 C 3 [1/V] -3.421e-3 1. C. PV system performance The yields of the PV system are expressed as reference yield (Y r ), given in [hr], array yield (Y a ) given in [hr] and final yield (Y f ) given in [hr], as well as the performance ratio (PR) expressed in [%], they can be obtained from the simulation results using the following formulas [14] III. RESULTS & DISCUSSION (14) (15) (16) (17) The layout of the developed virtual instrument can be viewed in front panel format for an interactive user interface, including the weather station, PV system & wind energy analysis. In figure 2, is shown the interface devoted to the description of the PV system and its configuration. Fig. 2 PV system description panel including configuration Fig. 3 Measured and simulated data represented in indicators. 70

Fig. 4.a DC power (simulated Vs Measured) Fig. 5 Daily performance ratio Fig. 4.b AC power (simulated Vs measured) Meanwhile, in figure 4, is presented the interface where indicators displaying all the radiometric data measured with electrical data measured and simulated including the gain in CO 2 emission. Simulated DC and AC power are shown in figure (4.a) and (4.b), as we notice a good agreement between data obtained from simulation and those obtained from measurements. Concerning the performance ratio, the graphical presentation is given in figure 5, a good agreement is found between simulation results and monitored data. For the wind energy part, the Weibull distribution estimation is given with simulation performed using an aerogenerators, the results of these simulations are given respectively in figures 6 and 7. Fig. 6 Fitted Weibull distribution. 71

Fig. 7 Aerogenerator simulated energy and power. IV. CONCLUSION The PV system and the weather station existing at the level of our establishment was monitored, modelled and performance were computed thanks to the reliable and friendly LabVIEW platform. The results obtained by the simulation were validated using measured data; the comparison has shown a good agreement, approving then the models we have chosen. By developing a platform under LabVIEW has enabled us the acquisition and control of data for the PV system. A friendly display has made the platform more attractive. The aim was also to create a data base for measurements which are performed since 2004, giving a huge amount of recordings, currently existing at the level of our laboratory, for future utilization. Furthermore, the work will be exploited in future for web page design. V. REFERENCES [1] Chouder A., Santiago S., Taghezouit B., Karatepe E., Monitoring, modelling and simulation of PV systems using LabVIEW. Sol. Energy, Vol.91 (2013), pp. 337-349. [2] De Asmundis R., Labview modeling, programming and simulations, In Tech, (2011). [3] Travis J., Kring J., LabView for everyone, Edition Prentice Hall, 3ème edition 2007. [4] Koutroulis, E., Kalaitzakis, K. Development of an integrated data acquisition system for renewable energy sources systems monitoring. Renewable Energy Vol. 28 (2003), pp. 139 152. [5] Forero, N., Herna ndez, J., Gordillo, G, Development of a monitoring system for a PV solar plant. Energy Conversion and Management. Vol. 47, (2006), pp. 2329 2336. [6] Hadj Arab, A., Cherfa, F., Chouder, A., Chenlo, F., Grid connected photovoltaic system at CDER-Algeria. In: Proceedings of the 20th European Solar Energy Conf. and Exhibition, Barcelona, Spain, (2005). [7] The Institute of Electrical and Electronics Engineers, IEEE Recommended practice for utility Interface of photovoltaic (PV) systems, IEEE Std. 929-2000, NY, (2000). [8] Ortiz-Rivera E., Peng F., Analytical model for a photovoltaic module using the electrical characteristics provided by the manufacturer data sheet, in Power Electronics Specialists Conference. IEEE 36th, pp. 2087 2091. (2005) [9] Ortiz-Rivera E., Modelling and Analysis of Solar Distributed Generation, PhD, 2006, East Lansing, MI, USA. [10] Ortiz-Rivera E., Peng F., A Novel Method to Estimate the Maximum Power for a Photovoltaic Inverter System, Proceedings of the 35th IEEE Power Electronics Specialists Conference,, pp. 2065-2069, Aachen, Germany. (2004) [11] David L. King, Sigifredo Gonzalez, Gary M. Galbraith, William E. Boyson, Performance Model for Grid- Connected Photovoltaic Inverters, SAND2007-5036, Sandia National Laboratories,, Albuquerque, NM, (2007). [12] David L. King, Boyson W.E., Kratochvill J.A., Photovoltaic Array Performance Model, SAND2004-3535, Sandia National Laboratories, Albuquerque, NM, (2004). [13] Chouder A., Silvestre S. Sadaoui N., Rahmani L., Modelling and simulation of a grid connected PV system based on the evaluation of main PV module parameters, Simulation Modelling Practice and Theory, Vol. 20 (2012), pp. 46 58. [14] Haeberlin, H., Beutler, Ch., Normalized representation of energy and power for analysis of performance and online error detection in PV systems, 13th EUPV Conference on Photovoltaic Solar Energy Conversion, Nice, France, (1995) pp. 934 937 72