Central Snap. Condition Details C SNAPDETAILS

Similar documents
* Other widths available upon request. 24 Gauge Galvalume - Standard Surface. Other gauges and aluminium available upon request.

IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE WEATHER GUARD PANEL.

EVERSEAM 20 APPLICATION GUIDE

StrongSeam SSFF1 Panel

Product Guide HELPFUL INFORMATION ON PANELS, TRIMS, GUTTERS AND ACCESSORIES

RESIDENTIAL LIGHT GAUGE APPLICATION GUIDE

KBS-100 SNAP-LOCK PANEL & 5V PANEL I N S T A L L A T I O N M A N U A L

Table of Contents. Notes to Designer/User Map of Typical Roof Conditions...3 Fastener Placement...4 Fastener Selection...5

ALLMET CONTINENTAL INSTALLATION GUIDE

Standing Seam Installation Guide

Pacific Tile Counter Batten and Batten

Pacific Tile Counter Batten and Batten

Classic and NB Tile Counter Batten and Batten

INSTALLATION GUIDE.

Installation Guide MATTERHORN METAL ROOFING TO LAST A LIFETIME. MATTERHORN Tile

Classic Rib Roofing Panels DETAIL MANUAL

TRIAD CORRUGATED METAL, INC.

BARREL VAULT Tile Counter Batten and Batten Installation Guide

TYPICAL ROOF CONDITION LAYOUT

Roofing Installation Manual: Concealed Fastener Panels Material Data, Trim Details, and Step-by-Step Instructions

Prior to ordering and installing materials, all dimensions should be verified by field measurements.

Black s Metals Installation Guide

Brava Spanish Tile. Installation Manual. Brava Roof Tile Phone: Fax:

PROLOK EAVE PROLOK ROOFING PANEL ROOFING NAIL

4572 N Old US 31, Rochester, IN Toll Free: Fax: Installation Guide SUPER-LOC 16 STANDING SEAM

SHURLOC 150 STANDARD DETAILS

4572 N Old US 31, Rochester, IN Toll Free: Fax: Installation Guide SUPER-LOC 16 STANDING SEAM

For Metal Roofing Systems Fascia, Mansards,& Soffits

Western States 7/8 Corrugated

WESTERN RIB. Installation, Flashings & Shop Drawing Detail Guide.

2120 SW Poma Drive; Palm City, Florida Phone Fax

ABSeam Panel Overview and Installation Instructions

a division of NCI Standing Seam Roof Systems

ENERGY STAR PARTNER. PBR & R Panel

4572 N Old US 31, Rochester, IN Toll Free: Fax: DETAIL MANUAL. and guide to Ramco Supply products

R PANEL / PBR PANEL. Installation, Flashings & Shop Drawing Detail Guide.

5V Crimp DESIGN/INSTALLATION INFORMATION

Installing the Sno-free Panel Eave System for New Roofs

Installation Guide. Mission Tile. Distributed by: BEST MATERIALS LLC, Phoenx AZ

Agenda. Safety Decking Basics Decking Issues Felt Kick Out Flashing Fascia

SIDEWALL/ENDWALL STANDING SEAM TRIMS SIDEWALL/ENDWALL CROSS SECTION NTS SIDING OR OTHER WALL CLADDING, TYP LOW PROFILE FASTENER, TYP

w w w. s a q u l i t y m e ta l s. c o m

2120 SW Poma Drive; Palm City, Florida Phone Fax

Architectural Roof and Wall Products Guide Specifications

SECTION PREFORMED CLADDING. A. Part A and DIVISION 1 of PART B are hereby made a part of this SECTION.

DL-200. Specifications

Architectural Roof and Wall Products Guide Specifications

Resysta Gold and Platinum Decking Installation Guidelines

Installation Guide. Titan Slate. Rev102606

Flat. Ribbed Striated and 1 ½ TCM-Lok Installation Manual

Architectural Wall Products Guide Specifications

Architectural Roof Products Guide Specifications

Architectural Roof Products Guide Specifications

CONTOUR CORRUGATED PANEL

SSL-175. Specifications

TRIAD CORRUGATED METAL, INC.

Recla Metals RCM INSTALLATION GUIDELINES

SLATE ROOFING INSTALLATION PROPOSAL [Last updated 10/08/2017]

ROOF OWNER'S OPERATION AND MAINTENANCE MANUAL

SNAP-LOK 1 1/2 Installation Manual

PBR & PBU PANELS. Technical/Installation Information

INSTALLATION MANUAL Heritage Series

6x5. Assembly Manual CAUTION. Sharp Edges PATENTS ARE PENDING. Building Dimensions. Approximate Size. Storage Area. Interior Dimensions

PATENTS ARE PENDING. Building Dimensions. Exterior Dimensions Roof Edge to Roof Edge

JUNIOR HF Steel Roof Panels

FF100 SNAPLOCK INSTALLATION MANUAL

Central Seam Plus. Central-Loc

PATENTS ARE PENDING. Building Dimensions. Exterior Dimensions Roof Edge to Roof Edge

Guide Specifications ADP Series SECTION SHEET METAL ROOFING

Battenless. Installation Guide BATTENLESS INSTALLATION GUIDE 1

CONSTRUCTION DETAILS HANDBOOK

1 1/2" SSR. FABRAL The pursuit of excellence since 1967

w w w. s a q u l i t y m e ta l s. c o m

TECHNICAL INFORMATION

ROOFING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION

Chapter 7. Roof Framing

SECTION METAL ROOF AND SOFFIT PANELS

TABLE OF CONTENTS PRODUCT CATALOGUE fax OVERVIEW PBR 7.2 LONGSPAN ECONORIB

3' COMMERCIAL RIB PREFORMED METAL SIDING

DEXERDRY INSTALLATION INSTRUCTIONS - PAGE - 1

Architectural Roof and Wall Products Guide Specifications

SECTION COPPER STANDING SEAM ROOFING

SIDEWALL/ENDWALL EXPOSED FASTENER TRIMS. Details master.dwg 2/15/2017 GULF COAST SUPPLY & MFG., LLC

Revision Date: April 01, Premier Vinyl Enclosure

FABRAL The pursuit of excellence since 1967

RIB PANEL INSTALLATION

STONE COATED METAL ROOF SHINGLE

1. Selective Demolition Section Adhered PVC Roofing System Section Sealants and Caulking Section 07920

CS-100 Guide Specifications

PV Mounting System 2703 SERIES 200 UL GROUND MOUNT SYSTEM. SnapNrack Residential PV Mounting Systems Code Compliant Installation Manual

Central Snap. Product Guide. 16" or 18" COVERAGE 1¾" HELPFUL INFORMATION ON PANELS, TRIMS, GUTTERS AND ACCESSORIES

Section STRAIGHT BARREL MISSION ROOFING TILE PART 1 - GENERAL 1.1 SUMMARY

METAL ROOFING: RE-ROOFING QUESTIONS & ANSWERS

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION METAL ROOF PANELS

ML-150. w w w. s a q u l i t y m e ta l s. c o m. san antonio branch 210 W. Peden San Antonio TX P. (210) F.

SECTION PRE-ENGINEERED METAL BUILDING

STILE. Panel Information. Design/Installation Considerations. Flashing Profiles. Detail Conditions. Notes. Accessory Profiles. Testing Information

Conergy SolarFamulus II

C. Counterflashings at roof-mounted mechanical equipment, vent stacks, curbs, and miscellaneous roof penetrations.

Metafor Panel System Installation Guide

Transcription:

Central Snap Condition Details D C SNAPDETAILS150612.2

The men and women at Central States Manufacturing, Inc. would like to welcome you. OUR MISSION Central States Manufacturing, Inc. is a 100% employee-owned company devoted to the personal growth and well being of our owners. We are dedicated to increasing the value of our company by making Raving Fans of our customers through exceeding their expectations, being easy to do business with, demonstrating excellence in all aspects of our business and being committed to improving their business. It is our promise to maintain honesty and integrity with everyone our lives may touch. With thanksgiving for the blessings we have been given, we are committed to serving the communities where we live and work by giving back a portion of our time, talents and profits. Effective 06/2015 Information subject to change 3

INDEX Information in the catalog may vary by plant location. Please call your salesperson to verify product availability. Product Information...5 Important Information & Safety...6 Foot Traffic...7 Field Cutting...7 Roof Preparation Tips...7 Substructure Condition...8 Installation Overview...8 Panel Installation...9 Trim Installation...9 Eave Termination...10 Eave Detail/Flying Gable...11 Gutter Detail...12 Gable/Rake Detail...13 Gable - Option 2...14 Sidewall Detail...15 Sidewall - Option 2...16 Endwall Detail...17 Valley Detail...18 Pitch Change Detail...19 High Eave Detail...20 Ridge/Hip Detail...21 Vented Ridge Detail - Option 1...22 Vented Ridge Detail - Option 2...23 This document illustrates conditions and details that are recommended for this product to minimize the number of potential water penetrations; alternative methods may be acceptable. 4 Effective 06/2015 Information subject to change

CENTRAL SNAP Central Snap is a performance rated non-structural, architectural standing seam roof system. It has an easy to install 13/4 high snap-lock joint making it ideal for architectural and light commercial applications. Central Snap is available in net coverage widths of 16 or the economical 18. It offers an architecturally pleasing look over metal or wood decking. 3:12 pitch or greater. Snap-together panel, no field seaming required. Available in 16" or 18" coverage. Factory applied sealant insures a weather-tight and secure lap. Available with a 11/8" notch on either end of the panel for the ease of turning under; reducing installation labor and costs. Should be installed over solid substrates but can be installed over framing depending upon the panel width and support member spans. Effective 06/2015 Information subject to change 5

IMPORTANT INFORMATION This manual contains suggestions and guidelines on how to install Central Snap panels. The drawings in this guide are for illustration purposes only and may not apply to all building designs or product applications. The installation details shown are proven methods of construction, but are not intended to cover all instances, building requirements, designs, or codes. It is the responsibility of the designer/installer to ensure that the details meet particular building requirements. The designer/installer must be aware of, and allow for, expansion/contraction of roof panels. The details may require changes or revisions due to each project s conditions. There are certain minimum live, snow, dead, collateral, and wind loads that a roof must generally be designed to support. Consult local building officials to determine the appropriate building design load requirements. A professional engineer should be consulted for all roof system designs. It is the buyer s responsibility to verify all applicable code requirements, check all measurements, and determine suitability of product for the job. The buyer is also responsible for determining lengths and quantities needed. Prior to ordering and installing materials, all dimensions should be verified with field measurements. Implied warranties of merchantability and fitness for a particular purpose are disclaimed. All Central Snap instructions assume that a qualified firm or individual has been contacted regarding application of this product. Failure to comply with stated recommendations relieves the manufacturer of responsibility for any damage or deterioration of the product incurred and voids any applicable warranty. Central States Manufacturing reserves the right to modify, without notice, information in this guide. If you have questions regarding proper installation of Central Snap or information not included in this guide, contact your salesperson. SAFETY Each job site presents different hazards; therefore it is the responsibility of the buyer/installer to determine the safest way to install the Central Snap roof panel system based on the recommended instructions contained in this guide. Provide crew members working on the roof with required safety railing, netting or safety lines. If you must walk on a metal roof, take great care. Metal panels can become slippery, so always wear shoes with nonslip soles. Avoid working on metal roofs during wet conditions when the panels can become extremely slippery. Walking or standing on a metal roof which does not have a plywood or other deck beneath it is not recommended. However, if you must do so, always walk on the purlins, never between. Central Snap is designed to be installed over solid plywood decking. OSHA safety regulations should be complied with at all times. CAUTION Always wear heavy gloves when working with steel panels to avoid cuts from sharp edges. When power cutting or drilling steel panels, always wear safety glasses to prevent eye injury from flying metal fragments. 6 Effective 06/2015 Information subject to change

FOOT TRAFFIC Care of metal panels and flashings must be exercised throughout erection. Foot traffic can cause distortion of panel and damage to finish. Traffic over the installed system must be kept to an absolute minimum. If continuous foot traffic is necessary for maintenance over certain areas of the roof, then a permanent walkway should be installed. If continuous foot traffic is necessary during installation, provide walking platforms to avoid any panel damage, or leave panels off where there is easiest access to roof until projects is almost complete. Then install panels in this area. When walking on the roof panels is unavoidable, walk only in the flats of the panel. Walking on the ribs can cause damage to the panels. All applicable safety regulations, including OSHA regulations, should be complied with during the panel installation process. CAUTION FIELD CUTTING There are a number of ways to cut sheet metal quickly and accurately. Tin snips or a nibbler type electric tool are recommended for field cutting Central Snap panels. Cutting over a trash barrel will help catch the tiny metal shavings that the machine produces. Although CSMI discourages it, if a power saw is used, the blade will generate slivers of metal chips. These slivers and metal chips must be immediately removed from the Central Snap panels because they will damage the finish and shorten the life of the product. One method of preventing this problem is to flip the panels over when cutting. This allows the slivers and metal chips to be brushed from the back and avoids damaging the paint on the top of the panels. Make sure that stacks of panels are away from the cutting area so shavings do not blow onto other panels. All product surfaces should be free of debris at all times. Installed surfaces should be wiped clean at the end of each work period. Never cut panels over metal surfaces. Metal shavings will rust on the surface, voiding the warranty. When cutting metal panels, always wear heavy gloves to avoid cuts from sharp edges and safety glasses to prevent eye injury. CAUTION ROOF PREPARATIONS TIPS Central Snap is designed to be installed over solid decking. We recommend a minimum 1/2 plywood sheathing Make sure any existing decking is smooth, level and in good condition. Replace any decking not meeting those requirements. If there is an existing asphalt shingle roof it must be removed. Make sure the roof is clear of any debris that might interfere with installation. Use minimum 30 lb. felt or synthetic underlayment. Use an alignment or chalk line where the first panel is installed. Central States recommends that this line be vertical and 1/4 from the rake edge of the roof deck and square with the eave. Other methods of confirming the squareness can also be used. Effective 06/2015 Information subject to change 7

SUBSTRUCTURE CONDITION Panel distortion may occur if not applied over properly aligned and uniform substructure. The installer should check the roof deck for squareness before installing Central Snap panels. Several methods can be used to verify squareness of the structure for proper installation of the panels. Method A One method for checking the roof for squareness is to measure diagonally across one slope of the roof from similar points at the ridge and eave and obtain the same dimension. Method B The 3-4-5 triangle system may also be used. To use this system, measure a point from the corner along the edge of the roof at a module of three (3). Measure a point from the same corner along another edge at a module of four (4). Then, by measuring diagonally between the two points established, the dimension should be exactly a module of five (5) to have a square corner. Multiple uses of this system may be required to determine building squareness. If the endwall cannot be made square the roof system cannot be installed as shown in these instructions. INSTALLATION OVERVIEW Familiarize yourself with all installation instructions before starting work. Before beginning installation, you should examine the substrate or framing to ensure that all supporting members are straight, level, and plumb to avoid any panel distortion. Substructures should be designed to meet all necessary code requirements. Some field cutting and fitting of panels and trims is to be expected by the installer and minor field corrections are a part of normal installation work. It is the responsibility of the installer to ensure a suitable substrate prior to the application of Central Snap. Distortion in the panel caused by an uneven substrate, ripples, or laps in the vapor barrier, debris, protruding nails and staples, etc., are not defects in the materials and are not the responsibility of Central States Manufacturing. All trims, closures, and accessories shown on the installation drawings are available from Central States Manufacturing unless noted otherwise. Oil canning in the flat area of the panels is common to the industry and does not affect the integrity of the panel. Therefore, oil canning is not a reason for rejection. The panels should be installed plumb, straight, and square to the eave. To keep the bottom edge of the roof perfectly straight and even, the panels must be installed square to the bottom edge. Begin by checking the roof for square; if it is square, you may pull the layout marks directly from the edge of the rake. If the roof isn t perfectly square, install the first panel parallel to your square line, making sure that the first rib does not hang over the gable edge of the roof sheathing. (Any overhang can prevent the gable trim from fitting tight against the rake.) NOTE: Copper metallic panels must be installed in the same direction! See directional arrows or stickers provided with your metal panel order. 8 Effective 06/2015 Information subject to change

1. Align the female edge of the first panel with the chalk line that was snapped at the rake edge. This line can be 0 1 3/4 from the rake. Panel should hook onto roof cleat or RDC trim. 2. Panels should be installed perpendicular to ridge for ridge trim attachment. Check panel alignment. If panel is properly aligned proceed. 3. Align the second panel female edge with the starter panel male edge. Panels must be flush to one another. Remember, panels should hook onto the male section at the eave. 4. Lightly compress and snap panels together at seam. Snap panels from eave to ridge. Put next set of clips in place. 5. Continue to apply panels as in steps 3 and 4. 6. Panels at the eave can be terminated in two ways; with fasteners and without. Each will depend on aesthetic conration determined by the installer or building owner. PANEL INSTALLATION FASTENER SPACING Maximum clip spacing 3' on center, for 16 wide 24 gauge panels with wind loads up to 90 mph On runs of more than 10 2 that require more than one length of trim, overlap the pieces by 2". The material is thin enough that the overlaps are not noticeable. Trim is attached with rivets or gasketed screws; take care to drive the screws enough to flatten the neoprene washer but not enough to deflect the roofing or the trim. The tricky part is finishing the ends of each trim run. It may take a bit more time, but cutting and folding the ends of the trim will give the roof a more finished look. When hooking the hem, measure over on hem 3 from end of trim piece. Cut hem 1/8 up from the bend to 3 mark. Cut off back of hem. On lap piece, open up hem with screwdriver. Insert piece. Slide together. Use rivets and sealant on lap where needed. TRIM INSTALLATION Effective 06/2015 Information subject to change 9

EAVE TERMINATION NOTE: Panels can be ordered with optional factory notch to save you time. STEP 1: Place the hemming tool over the notched tab in the panel. STEP 2: For eave conditions: Using hemming tool, bend the tab down 90 to engage drip edge (CSLRDC) style (position 1), using the lip on the Drip Edge trim to secure the panel in place at the eave as shown on page 11. Then hand finish the hem to 180. For transition and valley conditions: Using the hemming tool, bend under to 180 (position 2). 2 1 LAP SEAL PANEL HEM 10 Effective 06/2015 Information subject to change

EAVE/FLYING GABLE DETAIL REQUIRED TRIMS: EAVE FLASHING CSLRDC102(color) TRIM CLEAT CSLTC102 FIXED CLIP CSLCLP Effective 06/2015 Information subject to change 11

GUTTER DETAIL REQUIRED TRIMS: BOX GUTTER CSLGU102(color) EAVE FLASHING CSLRDC102(color) GUTTER STRAP CSLGS102(color) 12 Effective 06/2015 Information subject to change

GABLE/RAKE DETAIL REQUIRED TRIMS: GABLE TRIM ANGLE VSRGTA102(color) GABLE FLASHING CSLGA102(color) TRIM CLEAT CSLTC102 ROOF CLEAT CSLRCL102 FIXED CLIP CSLCLP Effective 06/2015 Information subject to change 13

GABLE/RAKE DETAIL OPTION 2 3/16" X 7/8" TAPE SEALANT CSLGJ GABLE TRIM REQUIRED TRIMS: GABLE FLASHING CSLGJ102(color) 17 8" TRIM CLEAT CSLTC102 FIXED CLIP CSLCLP 5" 14 Effective 06/2015 Information subject to change

SIDEWALL DETAIL REQUIRED TRIMS: GABLE TRIM ANGLE VSRGTA102(color) RAKE FLASHING CSLRA102(color) COUNTER FLASHING CSLCF102(color) FIXED CLIP CSLCLP Effective 06/2015 Information subject to change 15

SIDEWALL DETAIL OPTION 2 J-CLOSURE 3/16" X 7/8" TAPE SEALANT REQUIRED TRIMS: RAKE FLASHING CSLRA102(color) COUNTER FLASHING CSLCF102(color) J CLOSURE CSLJC ¾" 1 ½" 1 ¾" FIXED CLIP CSLCLP 4" 16 Effective 06/2015 Information subject to change

ENDWALL DETAIL REQUIRED TRIMS: ZEE CLOSURE CSLZEE102(color) ENDWALL FLASHING CSLEW102(color) COUNTER FLASHING CSLCF102(color) FIXED CLIP CSLCLP Effective 06/2015 Information subject to change 17

VALLEY DETAIL REQUIRED TRIMS: VALLEY CSLVAL102(color) ROOF CLEAT CSLRCL102 FIXED CLIP CSLCLP 18 Effective 06/2015 Information subject to change

PITCH CHANGE DETAIL REQUIRED TRIMS: TRANSITION FLASHING CSLTR102(color) ZEE CLOSURE CSLZEE102(color) ROOF CLEAT CSLRCL102 FIXED CLIP CSLCLP Effective 06/2015 Information subject to change 19

HIGH EAVE DETAIL REQUIRED TRIMS: HIGH EAVE FLASHING VSRGA102(color) TRIM CLEAT CSLTC102 FIXED CLIP CSLCLP ZEE CLOSURE CSLZEE102(color) 20 Effective 06/2015 Information subject to change

RIDGE/HIP DETAIL REQUIRED TRIMS: RIDGE CAP CSLHR102(color) ZEE CLOSURE CSLZEE102(color) FIXED CLIP CSLCLP Effective 06/2015 Information subject to change 21

VENTED RIDGE DETAIL OPTION 1 REQUIRED TRIMS: RIDGE CAP CSLHR102(color) PROFILE RIDGE VENT CSLVENT CSLHR102 PROFILE RIDGE VENT CLIP CSLVENTCLIP CSLVENT CSLVENTCLIP 22 Effective 06/2015 Information subject to change

VENTED RIDGE DETAIL OPTION 2 REQUIRED TRIMS: VENTED RIDGE CAP CSLVRDG102(color) ZEE CLOSURE CSLZEE102(color) PREVENT PREVENT FIXED CLIP CSLCLP Effective 06/2015 Information subject to change 23

NOTES 24 Effective 06/2015 Information subject to change

www.centralstatesmfg.com Copyright 2015 by Central States Manufacturing, Inc.