Precision Geosynthetic Laboratories

Similar documents
Marking and packing check Acceptable. Take photo during the goods Subject to buyer s evaluation. Sampling test at SGS lab Acceptable

PERFORMANCE EVALUATION TEST REPORT. Rendered to: CBT SUPPLY, INC. / D.B.A. SMARTDESKS

SGS MUSCOWPETUNG ABORIGINAL CONSTRUCTION MONITORING

SGS Germany GmbH. Test Report No.: H0RD0002

REPORT ON LEVEL 1 EARTHWORKS INSPECTION AND TESTING

BARGE SAMPLING AND ANALYSIS REPORT

SGS Korea Level II Data Report

14104 ORANGE AVENUE, PARAMOUNT, CALIFORNIA TELEPHONE (562) FAX (562) Website: AQLramtech.

REPORT NUMBER: SAT-004A ORIGINAL ISSUE DATE: April 13, 2017 REVISED DATE:

REPORT NUMBER: SAT-001A ORIGINAL ISSUE DATE: December 18, 2012 REVISED DATE:

REPORT NUMBER: SAT-001A ORIGINAL ISSUE DATE: April 30, 2013 REVISED DATE:

TYPICAL PHYSICAL STRENGTH PROPERTIES OF PRO TILE

SGS MUSCOWPETUNG ABORIGINAL CONSTRUCTION MONITORING

REPORT NUMBER: SAT-001A ORIGINAL ISSUE DATE: December 29, 2011 REVISED DATE:

REPORT NUMBER: SAT-001A Rev 1 ORIGINAL ISSUE DATE: November 16, 2010 REVISED DATE: June 20, 2011

Test Report No: (3) R1 Date: 06-Nov-17 Page 1 of 7

RENDERED TO. CastleRock Building Products Incorporated P.O. Box 1258 Meridian, ID USA 83680

ASTM E84-05 SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS

TEST REPORT. Acoustical Surfaces, Inc. ASTM E84-03 SURFACE BURNING CHARACTERISTICS. We Identify and S.T.O.P. Your Noise Problem.

TEST REPORT. Acoustical Surfaces, Inc. ASTM E84-03 SURFACE BURNING CHARACTERISTICS. We Identify and S.T.O.P. Your Noise Problems

REPORT NUMBER: SAT-001A ORIGINAL ISSUE DATE: March 13, 2017 REVISED DATE:

TEST REPORT. Acoustical Surfaces, Inc. ASTM E84-04 SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS. We Identify and S.T.O.P. Your Noise Problem

TEST REPORT. Acoustical Surfaces, Inc. ASTM E84-04 SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS. We Identify and S.T.O.P. Your Noise Problem

Alliance for Water Stewardship Assessment Report

REPORT NUMBER: SAT-001A ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

Shear Strength Evaluation of the EP Henry Cast Stone Wall System

REPORT NUMBER: SAT-002A ORIGINAL ISSUE DATE: August 16, 2017 REVISED DATE:

REPORT NUMBER: SAT-001D ORIGINAL ISSUE DATE: February 24, 2012 REVISED DATE:

INFRASTRUCTURE TECHNOLOGIES

SGS MUSCOWPETUNG ABORIGINAL CONSTRUCTION MONITORING

REPORT NUMBER: SAT-001A ORIGINAL ISSUE DATE: March 13, 2013 REVISED DATE:

DICKSON COATINGS FIRE TEST REPORT

Fire Testing Laboratory TEST REPORT FOR THERMORY USA, LLC Wilmette Avenue, Suite 208 Wilmette, IL 60091

DICKSON COATINGS FIRE TEST REPORT

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: October 30, 2014 REVISED DATE:

SHOWER WALLS S.A. DE C.V. FIRE TEST REPORT

ROOF PAVER SYSTEM National Distribution SPEC - SECTION 07760

Fire Testing Laboratory TEST REPORT

Prepared for: American Frame Manufacturing Co Bristow Court, Unit B San Diego, CA Phone: Web:


Test Report. Prepared For: Mr. Simone Furiato Ebrille S.r.l Strada Canelli, 53/a Nizza Monferrato (Asti)-Italy

Tech Spec 21. Capping and Compressive Strength Testing Procedures for Concrete Pavers. Background

AGA Roof Deck Pavers. AGA Concrete Paver. Technical. Pavers: Hydraulically pressed concrete pavers: 460 tons of pressure.

Code Compliance Research Report CCRR-0257

BRE Global Test Report

LISTING INFORMATION OF Epilay - Superior, Ultra and Platinum Roofing Underlayments SPEC ID: Epilay Inc S. Main Street, E1 unit C

Cornerstone R100 Segmental Retaining Wall Unit and SRW Products SRW5, SRW7, and SRW9 Series Geogrids Connection Strength Testing

Code Compliance Research Report CCRR-0118

IPE WOOD DECK TILES National Distribution SPEC - SECTION 07760

TEST REPORT. Rendered to: COLLINS LIMITED, LLC. For:

ACO Specification Information

TEST REPORT. Rendered to: All Weather Insulated Panels Vacaville, California. PRODUCT TYPE: Roofing Panels SERIES/MODEL: SR Series

FLEXURAL STRENGTH OF CONCRETE (THIRD-POINT LOADING METHOD) (Kansas Test Method KT-23)

KTA-TATOR, INC. 115 Technology Drive, Pittsburgh, PA July 7, 2011 Via

research report Cold-Formed Steel Walls with Fiberboard Sheathing Shear Wall Testing RESEARCH REPORT RP REVISION 2006

FINAL REPORT: CONNECTION STRENGTH TESTING TENSAR GEOGRIDS WITHIN MESA STANDARD BLOCKS AND MESA STANDARD CONNECTORS

Code Compliance Research Report CCRR-0187

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Concrete Strength Testing Technician Study Guide

Code Compliance Research Report CCRR-0194

WFCi Report # Conducted For: Supress Products LLC. 5/8 Supress Sound-Engineered Drywall SED58410C; U305 Design

TEST REPORT ON. TESTED FOR: Central States Manufacturing, Inc. 302 Jane Place Lowell, AR Telephone: (800) Fax: (800)

Test report of the room heater OVAL of PANADERO DENIA S.L.

SECTION PRECAST CONCRETE PAVERS AND PEDESTAL LOK DOWN SYSTEM

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES

P.O. Box ZN Bleiswijk Brandpuntlaan Zuid NZ Bleiswijk The Netherlands

ARCHITECTURAL TESTING, Inc. Code Compliance Research Report #0774 CCRR-0131

Structural Performance of 8-inch NRG Concrete Masonry Units. Report Compiled for: Niagara Regional Group. Date: January 28, 2013

Code Compliance Research Report CCRR-0225

TEST REPORT. Rendered to: TREMCO, INCORPORATED Beachwood, Ohio

Water Vapor Transmission for COVERAL PE Foam

SECTION INSULATING CONCRETE FORMING (ICF)

SouTHwEsT RESEARCH INSTITUTE

Report No Originally Issued: 05/2013 Revised: 07/17/2014 Valid Through: 05/2015

Prepared for: American Frame Manufacturing Co Bristow Court, Unit B San Diego, CA Phone: Web:

Report Number

REPORT NUMBER: SAT-001 ORIGINAL ISSUE DATE: March 23, 2010 REVISED DATE: NA

CSIRO Materials Science and Engineering 14 Julius Avenue, Riverside Corporate Park, North Ryde NSW 2113 Ph: Fax:

SUBJECT: Performance Testing of MCOR 5511; KTA-Tator, Inc. Project No

3.1 General. 3.2 Materials. 4.1 General. Page 1 of 6

Code Compliance Research Report CCRR-0153

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE Specification for Underground Enclosure Integrity

(Project Location) (your firm's name)

DS131 EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

NTPEP Evaluation of Spray Applied Non-Structural and Structural Pipe Liners for Storm Water Conveyance

NFP Epiradiateur Test. WF Report Number: (Issue 2) Test Sponsor: Fiba Tech Industries Limited. Date of original report:

AAMA/WDMA/CSA 101/I.S.2/A AAMA/WDMA/CSA 101/I.S.2/A AAMA TEST REPORT SUMMARY

ACCEPTANCE CRITERIA FOR METAL PLASTER BASES (LATH) PREFACE

Standard Test Method for Apparent Hoop Tensile Strength of Plastic or Reinforced Plastic Pipe by Split Disk Method 1

TEST REPORT. Report No.: G Rendered to: CR LAURENCE CO., INC. Vernon, California

TEST REPORT. Rendered to: ALL WEATHER INSULATED PANELS Vacaville, California. PRODUCT TYPE: Wall Panels SERIES/MODEL: DM45 Series

TEST REPORT ON. TESTED FOR: Central States Manufacturing, Inc. 302 Jane Place Lowell, AR Telephone: (800) Fax: (800)

COUNTY BLOCK. Construction Guidelines on County Block Steps. Special Considerations When Building Steps. Natural Beauty Absolute Strength

FROM: PROPOSED SUBSTITUTION: Use HILTI X-CW Ceiling Wire for Suspended Ceiling Systems

CONSTRUCTION MATERIALS

IMO Resolution MSC 307(88): Annex 1: Part 5

How to Design a Singly Reinforced Concrete Beam

GA GYPSUM BOARD TYPICAL MECHANICAL AND PHYSICAL PROPERTIES

Sept 30, 2004 Page 1 PRODUCT DESCRIPTION PRODUCT FEATURES

TEST REPORT ON 26 GA. PBR PANELS AT 5' 0" PANEL SPANS WITH 26 GA. SEALED N SAFE THERMAL BLOCKS IN ACCORDANCE WITH ASTM E AND AISI S907-08

Transcription:

Precision Geosynthetic Laboratories CLIENT: TILE TECH PAVERS Research Name: Flexural Strength of Tile Tech Pavers Mounted on Pedestal Paver Systems for City of Los Angeles Certification Application (PGL Job No. G080789) PRODUCT DESCRIPTION Tile specimen dimension is 18 x 18 x 1.75 complete with Pedestal system consisting of several components which includes: Top Cap, 4 diameter-12 height PVC pipe, Bottom Cap, and Buffer Pad. SAMPLE IDENTIFICATIONS: SAMPLE ID Research DATE RECEIVED ORIGIN CONTROL OF NUMBER MATERIAL 18 x 18 x 1.75 Tile Pavers 48543 7/15/08 Tile Tech Pavers 4 diameter PVC pipes 48545 7/15/08 Tile Tech Pavers Buffer Pad 48548 7/15/08 Tile Tech Pavers Top and Bottom Cover 48547 7/15/08 Tile Tech Pavers TESTS REQUIRED: TEST METHOD ASTM C293 - Modified DESCRIPTION Flexural Strength of Concrete (Modified for Tile Tech Pavers) TEST CONDITIONS: The samples were conditioned for a minimum of one hour in the laboratory at 22 + 2 o C (71.6 + 3.6 o F) and at 60 + 10% relative humidity prior to test. Preparation and Conduct of the Test: 1. Four (4) sets of Pedestal Paver Support Systems were arranged. 2. The support assemblies were properly positioned on top of the Compression Testing Equipment s base plate which acted as its foundation. 3. The 18 X18 Tile Paver specimen was placed on top of the equally spaced (square position) support assemblies sustaining each corner of the tile specimen. 4. The compression test was carried out by applying a normal concentrated load by way of lowering a one (1) inch diameter compression shaft/probe on the middle of the complete assembly at the rate of 0.04 inch/minute. 5. The apparatus read out at peak stress indicated that the specimen failed; readings were recorded to complete the test. 6. Steps 1 to 5 were performed on the remaining two (2) Tile Pavers. A total three (3) specimens were tested. 1160 North Gilbert Street, Anaheim, CA. 92801, Tel# 714-520-9631, Fax#714-520-9637 2015 Tile Tech Inc, All Rights Reserved. Page 1 of 6

Precision Geosynthetic Laboratories Other Attachments 1. Photos showing the performance of the test. TEST RESULTS: The test results are summarized in Table 1 indicated with the appropriate unit notations. PRECISION GEOSYNTHETIC LABORATORIES 7/23/08 Carmelo V. Zantua Technical/Laboratory Director 1160 North Gilbert Street, Anaheim, CA. 92801, Tel# 714-520-9631, Fax#714-520-9637 2015 Tile Tech Inc, All Rights Reserved. Page 2 of 6

TABLE 1. O BJECTIVE: Determination of Flexural Strength of Tile Paver s CLIENT: TILE TECH PAVERS P ROJECT NAME: Flexural Strength of Tile Paver s Date Started : 7/15/2008 Reported by: Date Reported: 7/23/2008 P GL Job No. : G08078 9 C lient Sample ID : Tile Pavers and Pedestal Paver Syste m M aterial Description: 18" x 18" x 1.75" Tile Pavers and Pedestal Paver Syste m SPECIMENS 1 2 3 Avg. Std. Dev. Min Ma x % RSD DESCRIPTION METHO D An 18" x 18" x 1.75" Tile Paver specimen was placed perpendic ular to the load-supplying and pedestal system. The specimens wer e placed on top of 4 sets of Pedestal Paver System. O ne set of the Pedestal Paver System consist of a top cap, 4" diameter-12" height PVC pipe, bottom cap, and buffer pad. The co mpression apparatus is equipped with a 1" pro be and tests were performed at a loading rate of 0.04"/min. A STM C293 F lexural Strength o f Concrete Sample 1 Sample 2 Sample 3 ( Modified for Tile Tech Pavers) A verage Width at the fracture, inch es 17.94 17.93 17.93 17.93 0.01 17.93 17.94 0.0 4 A verage Depth at the fracture, inches 1.82 1.78 1.77 1.79 0.03 1.77 1.82 1.51 Span length, inches 14.00 13.97 14.00 13.99 0.02 13.97 14.00 0.12 M odulus of Rapture, psi 775 874 778 809 57 775 874 7.0 M odulus of Rapture, psf 111545 125918 112045 116503 8158 111545 125918 7.0 L oad (lbs) 2189 2380 2071 2213 156 2071 23 80 7 E xtension ( in) 0.10 0.13 0.13 0.12 0.02 0.10 0.13 16.2 2 Precision Geosynthetic Laboratories 2015 Tile Tech Inc, All Rights Reserved. Page 3 of 6

CLIENT: TILE TECH PAVERS P.O. Box 5982 Los Angeles, CA 90055 Ronnie Tabibnia Test Report No: 914:015212 Date: September 4, 2008 SAMPLE ID: The following test material identified as Tile Tech Pedestal Bottom cap, nominal 3 mm thick. DATE OF RECEIPT: Entered into SGS USTC sample tracking system on September 2, 2008. TESTING PERIOD: September 4, 2008. AUTHORIZATION: TEST REQUESTED: Testing authorized by Ronnie Tabibnia. ASTM Designation D635-06 "Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position. TEST RESULTS: See page 2. CLASSIFICATION: The submitted sample is designated HB in accordance with para. X1.2.2. The submitted sample is classified CC1 in accordance with UBC Standard 26-7, SEC. 26.706.5 See classification requirements on page 2. Tested by Signed for and on behalf of SGS U.S. Testing Company Inc. Brian Ortega Greg Banasky Test Technician Supervisor Fire Technology Page 1 of 2 This document is issued by the Company under its General Conditions of Service for North America printed overleaf or accessible at http://www.sgs.com/terms_and_conditions.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company s findings at the time of its intervention only and within the limits of Client s instructions, if any. The Company s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This document can not be reproduced, except in full, without the prior written permission of SGS U.S. Testing Company Inc. Samples are not retained by the Company for more than 30 days, unless special arrangements are made. SGS U.S. Testing Company Inc. Consumer Testing Services 8385 White Oak Avenue Rancho Cucamonga, CA 91730 Member of SGS Group (Société Générale de Surveillance) 2015 Tile Tech Inc, All Rights Reserved. Page 4 of 6

Report No.: 914:015212 Date: September 4, 2008 CLIENT: TILE TECH PAVERS Page: 2 of 2 TEST RESULTS: Number of Specimens Tested: 10 Average Specimen Thickness: 3 mm nominal OBSERVATIONS: None specimens burned to the 25 mm mark. The specimens continued to burn after removal of the test flame for an average of 2 seconds. EVALUATION OF TEST FROM APPENDIX X1. X1.2: Category Designation- The behavior of the specimens can be classified HB (HB = Horizontal Burning) if, X1.2.1 There is no visible signs of combustion after the ignition source is removed, or X1.2.2 The flame front does not pass the 25 mm reference mark, or X1.2.3 The flame front passes the 25 mm reference mark but does not reach the 100 mm reference mark, or X1.2.4 The flame front reaches the 100 mm reference mark and the linear burning rate does not exceed 40 mm/min. for specimens having a thickness between 3 and 13 mm or 75 mm/min. for specimens having a thickness less than 3 mm. CLASSIFICATION REQUIREMENTS PER UBC STANDARD 26-7, SEC. 26.706.5 CC1: Plastic materials which have a burning extent of 1 inch (25mm) or less when tested in nominal.060-inch (1.5mm) thickness (or in the thickness intended for use) by this test. CC2: Plastic materials which have a burning rate of 2.5 inches per minute (64mm/min) or less when tested in nominal 0.060-inch (1.5mm) thickness (or in the thickness intended for use) by this test. ******** End of Report 2015 Tile Tech Inc, All Rights Reserved. Page 5 of 6

2015 Tile Tech Inc, All Rights Reserved. Page 6 of 6