3.17. PROCESS INTEGRATION AND PINCH TECHNOLOGY

Module 05: Pinch Design Method for HEN synthesis Lecture 27: Rules of Pinch Design Method (PDM) 2 nd Part Key words: PDM, HEN

Module 04 : Targeting. Lecture 11: PROBLEM TABLE ALGORITHM 1 st Part

Quiz Questions. For Process Integration. Fill in the blanks type Questions

HDA Process. compressor. Reactor. Flash. heat. cool. Stabilizer. Recycle. Product

Saturday 20 May C 180 C C 130 C C 60 C kw 50 C 30 C C 20 C

pinch 70 C 70 C 4 We want to cool both the hot streams to the pinch temperature. The next step is to find the duty for the two heat exchangers:

Process Integration: Unifying Concepts, Industrial Applications and Software Implementation

Retrofitting Heat Exchanger Networks Based on Simple Pinch Analysis

Debottlenecking and Retrofitting by Pinch Analysis in a Chemical Plant

DESIGN OF A HEAT EXCHANGER NETWORK BY GRAPH METHOD

Module 03 : Building blocks of PINCH Technology. Lecture 07 : Hot and Cold Composite Curves and The Pinch

Application of Heat Integration Techniques on Extract Column Section to reduce the cold utility requirements

Introduction to Pinch Technology

TEP Energy Utilization and Process Integration in Industrial Plants, or for short: Energy and Process

PINCH ANALYSIS: For the Efficient Use of Energy, Water & Hydrogen. PULP AND PAPER INDUSTRY Energy Recovery and Effluent Cooling at a TMP Plant

Reducing Hot and Cold Utility Requirements for Finishing Column Section Using Pinch Analysis Techniques

Researcher, 1(2), 2009, Energy Integration Of Crude Distillation Unit Using Pinch Analysis

Grand Composite Curve Module 04 Lecture 12

Pinch Analysis for Power Plant: A Novel Approach for Increase in Efficiency

Module 04: Targeting Lecture 14: No. of units target Key Words: HEN, Subset, Loop, Separate component, MER design

Heat Integration Improvement for Benzene Hydrocarbons Extraction from Coke-Oven Gas

Microeconomic Theory -1- Introduction and maximization

PINCH ANALYSIS: For the Efficient Use of Energy, Water & Hydrogen. PULP AND PAPER INDUSTRY Energy Recovery and Effluent Cooling at a TMP Plant

Minimizing Fresh and Wastewater Using Water Pinch Technique in Petrochemical Industries W. Mughees, M. Al-Ahmad, M. Naeem

On the use of heat pumps in total site heat integration

Energy Retrofit Studies in Diethyl Thiophosphoryl Chloride (DETC) Plant

Heat Exchanger Network Retrofit Comparison. Trevor Hallberg and Sarah Scribner

Wastewater Minimization in Process Industry Through Pinch Technology:

Energy efficiency and carbon footprint reduction for Croatian regions by Total Site integration

Retrofit of Crude Units Preheating Trains: Mathematical Programming versus Pinch Technology

Analysis of Heat Exchanger Network of Distillation Unit of Shiraz Oil Refinery

Energy Optimization Using Pinch Analysis

A Modified Energy Transfer Diagram for Heat Exchanger Network Retrofit Bridge Analysis

Combustion Chamber. Fig Schematic diagram of a simple gas turbine

Retrofit for a Gas Separation Plant by Pinch Technology

IDRIST Temporal pinch-point analysis for energy demand reduction in batch production. Thorsten Spillmann

Multi-effect distillation applied to an industrial case study

Energy Saving in Atmospheric Distillation Unit by Retrofit Design of Heat Exchanger Networks of Al Basra Refinery

An Energy Integration Approach on UHDE Ammonia Process

Heat Integration of Crude Organic Distillation Unit

Module 5: Process Integration of Heat and Mass Chapter 10. David R. Shonnard Department of Chemical Engineering Michigan Technological University

Module 05 Lecture 35 : Low temperature process design Key words: Refrigeration system

Steam System Network Analysis, Synthesis. and Optimisation. Sheldon Grant Beangstrom

Extended Total Sites with Multiple Energy Carriers

Energy Optimisation Of Upstream Separation And Stabilisation Plant Using Pinch Technology

Guidance page for practical work: optimization of combined cycles by the pinch method

Pinch analysis of Acrylic Acid Process Plant

A Novel Approach for Including Multi Phase Flows into Pinch Analysis The Heat Exchange Limits Estimated by the Advanced Composite Curves

Appendix A. The horizontal axis measures both GDP and Sales. The vertical axis measures the average price level.

Energy Efficiency Analysis Using Pinch Technology: A Case Study of Orbit Chemicals Industry

Targeting Minimum Heat Transfer Area for Heat Recovery on Total Sites

Effective Reduction of Industrial GHG Emissions via Energy Integration and Biomass Utilization

Modification of Preheating Heat Exchanger Network in Crude Distillation Unit of Arak Refinery Based on Pinch Technology

Application of combined pinch and exergy analysis in retrofit of an olefin plant for energy conservation

Optimized Heat Exchanger Network design of GTL (Gas-To-Liquid) process

Methodology for Batch Heat Integration and Storage System Design for Ideal Integration of Solar Process Heat

Utility-Heat Exchanger Grid Diagram: A Tool for Designing the Total Site Heat Exchanger Network

First Semester Course Handout (Part-II)

Optimising the Temperature of Heat Storage to Serve Processes with Varying Supply and Demand - Captured Solar Energy Curve

INVESTIGATION OF FLOW CHARACTERISTICS OF HELLER-TYPE COOLING TOWERS WITH DIFFERENT COOLING DELTA ANGLES

Pinch Analysis with crisscross optimization prior to design

Thermodynamics: An Engineering Approach, 6 th Edition Yunus A. Cengel, Michael A. Boles McGraw-Hill, 2008

Energy and water in the pulp and paper industry: the two solitudes

WATER AND ENERGY INTEGRATION: A COMPREHENSIVE LITERATURE REVIEW OF NON-ISOTHERMAL WATER NETWORK SYNTHESIS

Composite Table Algorithm - A Powerful Hybrid Pinch Targeting Method for Various Problems in Water Integration

Energy Balances and Numerical Methods Design Project. Production of Maleic Anhydride

1.4 Applications of Functions to Economics

Participant Plants and Streams Selection for Interplant Heat Integration among Three Plants

Indirect and mixed direct-indirect heat integration of batch processes based on Pinch Analysis

Energy Balances and Numerical Methods Design Project. Ammonia Production

HIGHER EFFICIENCY TARGETING IN A STEAM POWER PLANT BY USING PINCH TECHNOLOGY

Lecture 8. Design of cooling systems for effluent temperature reduction. L08-1 Energy System Design Update

Exploring inter-process heat integration opportunities for increased energy efficiency in industrial process clusters

Design of Crude Distillation Plants with Vacuum Units. II. Heat Exchanger Network Design

Practical Considerations. Richard Beaman, PE. Senior Chemical Process Engineer. Business Leader

Heat Exchanger Network Optimization using integrated specialized software from ASPENTECH and GAMS Technology.

Process Integration for Power-dominated Cryogenic Energy Systems 1. Introduction 2. Multi-period Synthesis of Power Systems

Fluid Mechanics, Heat Transfer, Thermodynamics Design Project. Production of Ethylbenzene

emissions reduction from smallscale utility system

Wastewater Minimization With Differentiated Regeneration of Contaminants using Water Source Diagrams (WSD)

Process intergration: Cooling water systems design

CN4205R Pinch Analysis and Process Integration

PINCH ANALYSIS : For the Efficient Use of Energy, Water & Hydrogen. NITROGEN-BASED FERTILIZER INDUSTRY Energy Recovery at an Ammonia Plant

University of Maiduguri Faculty of Engineering Seminar Series Volume 6, december 2015

OPTIMIZATION OF CRYOGENIC CARBON CAPTURE AND LNG PROCESSES BY SHAFTWORK TARGETING AND MATHEMATICAL PROGRAMMING

EconS 527 Homework 3 Answer Key. Consider a consumer with Cobb-Douglas utility function

Multi-Stage Cascade Refrigeration System

Fluid Mechanics, Heat Transfer, and Thermodynamics. Design Project. Production of Acetone

Chapter 4.3: Cogeneration, Turbines (Gas, Steam)

Energy Balances and Numerical Methods Design Project. Production of Methyl Tertiary-Butyl Ether

SYNTHESIS AND OPTIMIZATION OF DEMETHANIZER FLOWSHEETS FOR LOW TEMPERATURE SEPARATION PROCESSES

International Journal of Pure and Applied Sciences and Technology

Chapter 5 MASS AND ENERGY ANALYSIS OF CONTROL VOLUMES

Using this information, we then write the output of a firm as

Heat Integration Across Plants Considering Distance Factor

2 THINKING LIKE AN ECONOMIST

Methodology for the optimal thermo-economic, multi-objective design of thermochemical fuel production from biomass

Fluid Mechanics, Heat Transfer, Thermodynamics Design Project. Production of Styrene

CHAPTER 5 MASS AND ENERGY ANALYSIS OF CONTROL VOLUMES

Transcription:

3.1 INTRODUCTION... 2 3.2 DESIGN TOOLS: REPRESENTING HEAT -EXCHANGER NETWORKS... 4 3.2.1. The Grid Diagram...4 3.2.2. The Heat-Content Diagram...7 3.3 PRELIMINARY HEAT -EXCHANGER NETWORK DESIGN... 10 3.2.1 Pinch Subnetworks...13 3.3.2 Minimum Number of Heat-Exchange Units...16 3.3.4 Capacity-Flowrate Rule for Match Feasibility...22 3.3.5 Matches Away from the Pinch...26 3.3.6 Heaters and Coolers...27 3.3.7 Stream Splitting...35 3.4.1 Shifting Heat Loads around Network Loops...45 3.4.2 Shifting Heat Loads along Network Paths...49 3.5 SUMMARY... 53 REFERENCES... 55 NOMENCLATURE... 56

Chapter 3: Heat-Exchanger Network Design

3.1 Introduction In Chapter 2, we determined the minimum heating- and cooling-utility requirements for a heat-integration problem (Section 2.5), and compared it to the requirements for a similar system without heat integration (Section 2.4). Clearly, heat integration minimizes the use of heating and cooling utilities by maximizing heat transfer from hot streams to cold streams. Now that we have the system requirements, we turn our attention to heat-exchanger network design and explain how to construct a network that will accomplish the necessary heat transfer and satisfy the stream data using the least amount of heating and cooling utilities and the fewest number of heat-exchange units. Before developing heat-exchanger networks, this chapter first outlines some of the basic steps and key tools involved in designing any network (Section 3.2). From there, we will turn to the heat-exchanger network. Constructing a network for this system is a two-step process: 1. Design a preliminary heat-exchanger network guaranteed to accomplish the heat transfer from hot streams to cold streams (Section 3.3). 3-2

2. Simplify the preliminary network to reduce the number of heat-exchange units (e.g., heat exchangers, steam heaters and water coolers) through an evolutionary process (Section 3.4). 3-3

3.2 Design Tools: Representing Heat-Exchanger Networks We can represent a heat-exchanger network in a number of ways. Two common ones are grid diagram and the mass-content diagram. To illustrate these methods, let us look at a preliminary heat-exchanger network for Example 3.1 - a simple three-unit system consisting of one exchanger, one heater and one cooler. 3.2.1. The Grid Diagram The most common representation scheme is the grid diagram, in which each heatexchange unit is represented as a vertical line connecting two streams. In a grid diagram: Solid horizontal lines at the top of the diagram represent hot streams. These streams flow from the left (hot side) to the right (cold side) of the diagram. Solid horizontal lines at the bottom of the diagram represent cold streams. These streams flow from the right (cold side) to the left (hot side) of the diagram. Dashed horizontal lines at the top of the diagram represent heating utilities (e.g., steam). Multiple lines can, for example, represent high-pressure and low-pressure steam supplies. 3-4

Dashed horizontal lines at the base of the diagram represent cooling utilities (e.g., cooling water or refrigerants). Vertical lines represent heat-exchange unit. Each line can connect a hot and a cold stream, a hot stream and a cooling utility, or a cold stream and heating utility. We indicate the heat load of the unit (kw) within the circles connecting the lines, and also show the inlet and outlet temperatures of the hot and cold streams in each heat-exchange unit. Bold vertical dashed line(s) indicate the position of any pinch points for the system. Figure 3.1 shows the grid diagram for Example 3.1. 3-5

Pinch 75 C Steam 1000 (MC) p = 15 kw/ C 75 C 750 25 C (MC) p = 5 kw/ C 75 C 75 C 125 50 C (MC) p = 10 kw/ C 175 C 1000 750 0 C 125 Cooling Water Figure 3.1. Grid diagram of a preliminary heat-exchanger network for a simple three-unit example. Heat duties in kw. 3-6

As the next section makes clear, grid diagrams are an invaluable tool for designing and representing networks for heat integration. We may divide the grid diagram into subproblems across the regions defined by the pinch points. Within these regions, we apply simple design rules to achieve the minimum heating- and cooling-utility duties as well as the minimum number of heat-exchange units. 3.2.2. The Heat-Content Diagram Heat-content diagrams are yet another way to design and represent a heat-exchanger network (Nishida, et al., 1977). These diagrams provide an alternative to the grid diagrams and to give a visualization of each heat-exchange unit in the network. In a heat-content diagram: We represent each hot stream with a box on the hot side (above the x-axis), and each cold stream with a box on the cold side (below the x-axis). We label each corresponding pair of hot and cold boxes with the same letter. The top and bottom of a box on the hot side correspond to the supply and target temperatures of a hot stream, respectively. The width of the box, on the relative x-axis represents the heat-capacity flowrate of the hot stream. Therefore, the area of the box corresponds to the heat load of the hot stream. The bottom and top of a box on the cold side correspond to the supply and target temperatures of a cold stream, respectively. Once again, the width of the box, on the 3-7

relative x-axis represents the heat-capacity flowrate of the cold stream. Therefore, the area of the box corresponds to the heat load of the cold stream. Figure 3.2 shows the heat-content diagram for Example 3.1. 3-8

125 100 75 50 25 E1 750 kw 125 kw Temperature ( C ) 0 175 Enthalpy (kw) 150 125 1000 kw 100 75 50 25 E1 750 kw 0 Figure 3.2. Heat-content diagram for Example 3.1. 3-9

3.3 Preliminary Heat-Exchanger Network Design This section presents a method for designing preliminary heat-exchanger networks that guarantee to meet the minimum utility targets identified in Section 2.5. We examine the details of designing a preliminary heat-exchanger network for Example 2.1. In most cases, we first employ the shifted stream data to incorporate a minimum approach temperature into the design, and later adjust the temperatures to reflect the true approach temperatures within each heatexchange unit. We use Example 2.1 as a tutorial for designing preliminary heat-exchanger networks. Table 2.1 repeats the shifted stream data for Example 2.1. Through hot and cold composite curves (Figure 3.3) or a temperature-interval diagram (TID) (Table 3.2) we identify minimum heating- and cooling-utility duties of 1505 and 1375 kw, respectively. Table 2.1. Shifted stream data for Example 2.1. Temperatures shifted for a minimum approach temperature of 20 C. Stream T supply i T target i ( M & C p ) i DH i i (C) (C) (kw/c) (kw) 175 45 20 2600 125 65 40 2400 60 195 30 4050 80 152 15 1080 3-10

225 200 Heating-Utility Duty, 1505 kw 175 150 Shifted Temperature (C) 125 100 75 Hot Composite Curve Pinch Temperature, 125 C Cold Composite Curve 50 25 Cooling-Utility Duty, 1375 kw 0 0 1000 2000 3000 4000 5000 6000 7000 Enthalpy (kw) Figure 3.3. Hot and cold composite curves for Example 2.1. Temperatures shifted for a minimum approach temperature of 20 C. 3-11

Table 3.2. TID for Example 2.1. Temperatures shifted for a minimum approach temperature of 20 C. Hot Streams Cold Streams Shifted Temperature (C) 20 kw/c 40 kw/c Heat Surplus (kw) Cumulative Surplus (kw) 30 kw/c 15 kw/c Heat Deficit (kw) Cumulative Deficit (kw) Net Heat Surplus (kw) Cascaded Surplus (kw) Adjusted Surplus (kw) 45 0 0-130 1375 300 0 300 60 300 0-430 1075 100 150-50 65 400 150-380 1125 900 450 450 80 1300 600-830 675 2700 2025 675 125 4000 2625-1505 0 540 1215-675 152 4540 3840-830 675 460 690-230 175 5000 4530-600 905 0 600-600 195 5000 5130 0 1505 3-12

3.2.1 Pinch Subnetworks The nature of the pinch allows us to divide the design problem into subnetworks defined by the pinch temperature(s). Recall that no heat should be transferred across the pinch and that heating and cooling utilities should not be employed above and below the pinch, respectively. Beginning at the pinch and working away form the pinch, we select matches according to the design rules presented in Sections 3.3.2 and 3.3.4 to satisfy the stream data. Figure 3.4 is a grid diagram for Example 2.1. At this point, we have not identified heatexchange units. However, the problem is divided into two subnetworks above and below the pinch at a shifted temperature of 125 C. 3-13

Pinch 125 C Steam (MC) p = 20 kw/ C 175 C 45 C (MC) p = 40 kw/ C 125 C 65 C (MC) p = 30 kw/ C 195 C 60 C (MC) p = 15 kw/ C 152 C 80 C Cooling Water Figure 3.4. Grid diagram for designing a preliminary heat-exchanger network for Example 2.1 divided into two subnetworks above and below the pinch temperature. Temperatures shifted for a minimum approach temperature of 20 C. 3-15

3.3.2 Minimum Number of Heat-Exchange Units This section briefly presents Euler s graph theory for identifying the theoretical minimum number of heat-exchanger units from the number of process streams and utilities. Euler s graph theory gives us tools to evaluate heat-exchanger networks. Figure 3.5 illustrates simple diagrams with interconnected nodes (streams) linked with lines (heat-exchange units). In Figure 3.5a, five nodes are connected to each other through 5 lines. Here, four lines form a loop (ABCD). In contrast to Figure 3.5a, Figure 3.5b illustrates how five nodes can be connected via lines to form two independent components. Euler s graph theory relates the number of lines (units) to the number of nodes (streams), loops and independent components. In terms of heat-exchanger networks: N units = S + L C (3.1) where N units is the number of heat-exchanger units, S is the number of streams (including utilities), L is the number of loops and C is the number of independent components. Except in rare cases, loops can be eliminated (Section 3.4.2) and the number of independent components is one. Equation 3.6 becomes: N units = S 1 (3.2) 3-16

Node Loop Node Node Node Node Line (a) Node Node Node Node Node (b) Figure 3.5. Illustration of Euler's graph theory applied to heat-exchanger networks. 3-17

For systems where the pinch divides the design in to two separate components (see Section 3.3.2), the number of units is: N ( NH + HC + NHU 1) + ( NH + HC + NCU ) Abovethe Pinch Below thepinch units = 1 (3.3) where N H and N C are the number of hot and cold process streams, respectively, and N HU and N CU are the number of hot utilities above the pinch and cold utilities below the pinch, respectively. For the four process streams and two utilities of Example 2.1, Equation 3.3 gives the minimum number of units as: N units = = ( NH + HC + NHU 1) + ( NH + HC + NCU 1) Abovethe Pinch ( 1+ 2 + 1 1) + ( 2 + 2 + 1 1) = 7 Abovethe Pinch Belowthe Pinch BelowthePinch (3.4) 3.3.3 Maximize Exchanger-Heat Loads To minimize the number of heat-exchange units, we maximize the heat transferred in each exchanger by first identifying the total heat available from the hot stream and the heat required by the cold stream. Second, we choose the lesser of the two to maximize the heat transferred in the unit. Equations 3.3 and 3.4 modify Equations 3.1 and 3.2 to give the heat load available and required by hot and cold streams, respectively, above the pinch. Here, T * pinch is the pinch temperature. 3-18

Q kw = & p Hi Hi pinch (3.3) C supply * ( kw) ( MC ) [ T T ]( C) available Hi Q kw = & p Ci Ci pinch (3.4) C target * ( kw) ( MC ) [ T T ]( C) required Ci Similarly, Equations 3.5 and 3.6 give these heat loads below the pinch temperature. Q kw = & p Hi pinch Hi (3.5) C * target ( kw) ( MC ) [ T T ]( C) available Hi Q kw = & p Ci pinch Ci (3.6) C * supply ( kw) ( MC ) [ T - T ]( C) required Ci Figures 3.6 and 3.7 illustrate the two possible matches between hot and cold streams above the pinch for Example 2.1 (hot steam 1 to cold stream 1, and hot stream 1 to cold stream 2, respectively). In the figures, 500 kw are available from hot stream 1, while 1400 and 405 kw are required by cold streams 1 and 2, respectively. Figure 3.6 shows that to maximize the heat load of each unit, 500 kw are transferred from hot stream 1 to cold stream 1 (hot stream 1 limiting because 500 kw < 1400 kw). Figure 3.7 illustrates that only 405 kw are transferred from hot stream 1 to cold stream 2 (cold stream 2 limiting because 405 kw < 500 kw). 3-19

Pinch 125 C Steam 175 C 1000 (MC) p = 20 kw/ C 195 C 158.33 C 1000 (MC) p = 30 kw/ C 152 C (MC) p = 15 kw/ C Figure 3.6. Grid diagram of a match between hot stream 1 and cold stream 1 for Example 2.1 above the pinch. Temperatures shifted for a minimum approach temperature of 20 C. Heat duties in kw. 3-20

Pinch 125 C Steam 175 C 145.25 C 405 (MC) p = 20 kw/ C 195 C (MC) p = 30 kw/ C 152 C 405 (MC) p = 15 kw/ C Figure 3.7. Grid diagram of a match between hot stream 1 and cold stream 2 for Example 2.1 above the pinch. Temperatures shifted for a minimum approach temperature of 20 C. Heat duties in kw. 3-21

3.3.4 Capacity-Flowrate Rule for Match Feasibility With more than one possible match between a hot stream and a cold stream available, we select stream matches according to their capacity flowrates. A general rule for matching a hot stream to a cold stream is that the capacity flowrates of streams leaving the pinch temperature (i.e., hot streams above the pinch temperature or cold streams below the pinch temperature) must be greater than or equal to the capacity flowrate of streams approaching the pinch temperature (i.e., cold streams above the pinch temperature or hot streams below the pinch temperature). In other words, for matches at the pinch temperature: ( M Cp ) ( M& Cp ) out in & (3.7) For Example 2.1, Figure 3.8 illustrates the capacity flowrate rule. In the figure, the solid lines represent hot stream 1, and the dashed lines represent cold streams 1 and 2 in Figures 3.8a and b, respectively. In this case, we have drawn the streams in opposite directions (i.e., the hotside inlet is to the right and the outlet is to the left, while the cold-side inlet is to the left and the outlet is to the right) to better agree with the format of the grid diagram. Figure 3.8a illustrates the case where the capacity flowrate of the cold stream is greater than that of the hot stream (i.e., in agreement with the capacity-flowrate rule). Here, the streams diverge from right to left and heat transfer between the streams is always feasible. Recall that the capacity flowrate is equal to the slope of the stream on a T-Q diagram. However, in the case of Figure 3.8b, the capacity flowrate of the cold stream is less than that of the hot stream (i.e., against the capacity flowrate 3-22

rule). Now, we see that the cold stream is always above the hot stream on the T-Q diagram and heat transfer is infeasible. 3-23

175 (MC p) > (MC) p Temperature ( C) Feasible Heat Transfer 125 0 1000 Enthalpy (kw) (a) 175 (MC p) < (MC) p Temperature ( C) Infeasible Heat Transfer Temperature-Driving Force Violation 125 0 1000 Enthalpy (kw) Figure 3.8. T-Q diagram for matches between (a) hot stream 1 and cold stream 1 and (b) hot stream 1 and cold stream 2. (b) 3-24

3-25

A simple and effective technique for identify matches with respect to the capacity flowrates of streams entering and leaving the pinch is the tick-off table. Table 3.3 lists the capacity flowrates of the four streams of Example 2.1 above (left) and below (right) the pinch temperature. In the table, we match streams above the pinch by drawing lines from a cold stream to a hot stream (i.e. right to left) such that the line always points to a hot stream with a lower capacity flowrate. Conversely, below the pinch, we draw lines to identify matches from a hot stream to a cold stream (i.e., from left to right), such that the line always points to a cold stream with a lower capacity flowrate. Table 3.3. Tick-off table for Example 2.1. Above the pinch Below the Pinch Stream (MC p ) Hi (MC p ) Ci (MC p ) Hi (MC p ) Ci i (kw/ C) (kw/ C) (kw/ C) (kw/ C) 1 20 30 20 30 2-15 40 15 3.3.5 Matches Away from the Pinch Once we have identified the matches between hot and cold streams near the pinch temperature, the design problem is relaxed. In other words, away from the pinch temperature, we have greater latitude in selecting stream matches. It is at this point where we are likely to generate alternative designs for heat-exchanger networks. Here, we may consider other factors 3-26

like physical location, and stream compatibility to reduce network complexity or operational hazards. 3.3.6 Heaters and Coolers Figure 3.9 shows a preliminary heat-exchanger network for Example 2.1 where we have made all possible stream matches according to the design rules of Sections 3.2.1 to 3.3.5. Now, the remainder of the heat transfer must be accomplished through heating and cooling utilities. In Figure 3.10, we add 900 and 405 kw of heat to cold streams 1 and 2, respectively, with steam heaters above the pinch. In Figure 3.11, we remove 1100 and 125 kw of heat from hot streams 1 and 2, respectively, with water coolers below the pinch. Note that the total heating utility (900 kw + 405 kw = 1305 kw) and cooling utility (1100 kw + 125 kw = 1225 kw) agree with those determined through hot and cold composite curves (Figure 2.17) and a TID (Table 3.9). Figures 3.12 and 3.13 illustrate the complete heat-exchanger network for Example 2.1 on grid and heat-content diagrams, respectively. 3-27

Pinch 125 C Steam (MC p) H 1 = 20 kw/ C 175 C 1000 675 91.25 C 45 C (MC p) H 2 = 40 kw/ C 125 C 125 C 1950 76.25 C 65 C (MC p) = 30 kw/ C 195 C 158.33 C 1000 125 C 1950 60 C (MC p) = 15 kw/ C 152 C 675 80 C Cooling Water Figure 3.9. Grid diagram of a preliminary heat-exchanger network for Example 2.1 with all possible hot stream to cold stream matches. Temperatures shifted for a minimum approach temperature of 20 C. Heat duties in kw. 3-29

Pinch 125 C Steam 1100 405 175 C 1000 (MC) p H 1 = 20 kw/ C 195 C 1100 158.33 C 158.33 C 1000 (MC) p = 30 kw/ C 152 C 405 125 C (MC) p = 15 kw/ C Figure 3.10. Grid diagram of a preliminary heat-exchanger network for Example 2.1 above the pinch with two heaters. Temperatures shifted for a minimum approach temperature of 20 C. Heat duties in kw. 3-30

Pinch 125 C (MC) p = 20 kw/ C 675 91.25 C 91.25 C 925 45 C (MC) p = 40 kw/ C 125 C 1950 76.25 C 450 65 C (MC) p = 30 kw/ C 125 C 1950 60 C (MC) p = 15 kw/ C 675 80 C 450 925 Cooling Water Figure 3.11. Grid diagram of a preliminary heat-exchanger network for Example 2.1 below the pinch with two coolers. Temperatures shifted for a minimum approach temperature of 20 C. Heat duties in kw. 3-31

Pinch 125 C Steam 1100 405 (MC) p = 20 kw/ C 175 C 1000 675 91.25 C 91.25 C 925 45 C (MC) p = 40 kw/ C 125 C 125 C 1950 76.25 C 450 65 C (MC) p = 30 kw/ C 195 C 1100 158.33 C 158.33 C 1000 125 C 1950 60 C (MC) p = 15 kw/ C 152 C 405 125 C 675 80 C 450 925 Cooling Water Figure 3.12. Grid diagram of a complete preliminary heat-exchanger network for Example 2.1. Temperatures shifted for a minimum approach temperature of 20 C. Heat duties in kw. 3-33

200 175 175 C 150 E2 1000 kw 125 100 75 50 E1 675 kw 925 kw 20 kw/ C 125 C 91.25 C 45 C E3 1950 kw 40 kw/ C 125 C 450 kw 76.25 C 65 C 200 175 150 125 1100 kw E2 1000kW 195 C 158.88 C 152 C 405 kw 125 C 125 C Enthalpy (kw) 100 75 50 E3 1950 kw 30 kw/ C 60 C E1 675 kw 15 kw/ C 80 C 25 3-34

3.3.7 Stream Splitting For some problems, we may not be able to strictly follow the capacity-flowrate rule (Section 3.3.3) for stream matching. To illustrate this situation, we introduce Example 3.2. Here, we modify Example 2.1 so that we cannot follow the capacity flowrate rule for stream matching below the pinch. Tables 3.4 and 3.5 list the stream data and the shifted stream data, respectively, for Example 3.2 with a minimum approach temperature of 20 C. Table 3.4. Stream data for Example 3.2. Stream T supply i T target i ( M & C p ) i i (C) (C) (kw/c) 165 35 10 115 55 40 165 30 20 122 50 15 3-35

Table 3.5. Shifted stream data for Example 3.2 with a minimum approach temperature, D T min = 20 C. Stream T supply i T target i ( M & C p ) i i (C) (C) (kw/c) 155 25 10 105 45 40 175 40 20 132 60 15 Figure 3.14 and Table 3.6 are the composite curves and TID for Example 3.2, respectively. From either the figure or the table, we recognize that the pinch point remains at a shifted temperature of 125 C, while the minimum heating- and cooling-utility duties are increased to 1225 and 1305 kw, respectively. Figure 3.15 shows the streams and their capacity flowrates for Example 3.2. Table 3.7 lists the capacity flowrates of streams above and below the pinch for Example 3.2 for the tick-off matching procedure. We notice that above the pinch, there are two feasible matches - hot stream 1 to cold stream 2, or hot stream 1 to cold stream 2 (both 20 and 15 kw/c are greater than 10 kw/c). However, we are not so fortunate below the pinch. Table 3.7 shows that a match between hot stream 1 and cold stream 2 is infeasible (10 kw/c is less than 15 kw/c). 3-36

225 200 Heating-Utility Duty, 1305 kw 175 150 Temperature (C) 125 100 Hot Composite Curve Cold Composite Curve 75 Pinch Temperature, 125 C 50 25 Cooling-Utility Duty, 1225 kw 0 0 1000 2000 3000 4000 5000 6000 Enthalpy (kw) Figure 3.14. Hot and cold composite curves for Example 3.2. Temperatures shifted for a minimum approach temperature of 20 C 3-37

Table 3.6. TID for Example 3.2. Temperatures shifted for a minimum approach temperature of 20 C. Hot Streams Cold Streams Shifted Heat Cumulative Heat Cumulative Net Heat Cascaded Adjusted Temperature (C) 10 kw/ C 40 kw/ C Surplus (kw) Surplus (kw) 20 kw/ C 15 kw/ C Deficit (kw) Deficit (kw) Surplus (kw) Surplus (kw) Surplus (kw) 25 0 0-80 1225 150 0 150 40 150 0-230 1075 50 100-50 45 200 100-180 1125 750 300 450 60 950 400-630 675 2250 1575 675 105 3200 1975-1305 0 270 945-675 132 3470 2920-630 675 230 460-230 155 3700 3380-400 905 0 400-400 175 3700 3780 0 1305 3-38

Pinch 105 C Steam (MC p) = 10 kw/ C 155 C 25 C (MC ) = 40 kw/ C p 105 C 45 C (MC p) = 20 kw/ C 175 C 40 C (MC ) = 15 kw/ C p 132 C 60 C Cooling Water Figure 3.15. Grid diagram of hot and cold streams for Example 3.2. Temperatures shifted for a minimum approach temperature of 20 C. 3-39

Table 3.7. Tick-off table for Example 3.2. Above the pinch Below the Pinch Stream (MC p ) Hi (MC p ) Ci (MC p ) Hi (MC p ) Ci i (kw/ C) (kw/ C) (kw/ C) (kw/ C) 1 10 20 10 20 2-15 40 15 How do we supply the necessary heat to cold streams below the pinch? We have one hot stream available near the pinch (hot stream 2) and cannot use heaters below the pinch. We split the available hot stream and use a portion of its capacity flowrate to heat each cold stream. Figure 3.16 illustrates one method for splitting hot stream 2 to accomplish the heating of cold streams below the pinch. We supply a total of 1975 kw of heat to cold stream 1 (1300 kw) and cold stream 2 (675 kw) to raise the temperature of both to 125 C. We distribute the capacity flowrate of hot stream 2 to the cold streams in proportion to the heat loads of each unit: ( MC ) = ( MC ) p p 1300kW 1300kW + 675kW kw = 26.33 o C ( MC ) = ( MC ) p p 675kW kw = 13.67 o 1300kW + 675kW C 3-40

(MC) p = 10 kw/ C Pinch 105 C 31.25 C 25 C 105 C 26.33 kw/ C 1300 55.63 C (MC) p = 40 kw/ C 55.63 C 45 C 13.67 kw/ C 105 C 675 55.63 C (MC) p = 20 kw/ C 1300 40 C (MC) p = 15 kw/ C 675 60 C Cooling Water Figure 3.16. Grid diagram of a preliminary heat-exchanger network for Example 3.2 below the pinch featuring stream splitting. Temperatures shifted for a minimum approach temperature of 20 C. Heat duties in kw. 3-41

In the figure, we split hot stream 2 and supply 26.33 and 13.67 kw/c of its capacity flowrate to heat cold streams 1 and 2 from 40 to 105 C and from 60 to 125 C, respectively. The outlet temperatures from the two units are: T out = T in Q ( MC ) p o 1300kW = 105 C kw 26.33 o C o = 55.63 C ( kw ) kw o C T out = T in Q ( MC ) p o 675kW = 105 C kw 13.67 o C o = 55.63 C ( kw) kw o C The outlet temperatures for both units are equal because we distributed the capacity flowrate of hot streams 2 proportional to the heat duties of each unit. Figures 3.17 and 3.18 depict the entire preliminary heat-exchanger network for Example 3.2 including heating and cooling utilities on gird and heat-content diagrams, respectively. In Figure 3.18, we represent stream splitting with vertical lines. 3-42

Pinch 105 C Steam 900 405 (MC) p = 10 kw/c 155 C 500 31.25 C 800 25 C 105 C 26.33 kw/c 1300 55.63 C (MC) p = 40 kw/c 105 C 55.63 C 425 45 C 13.67 kw/c 105 C 675 55.63 C (MC) p = 20 kw/ 75 C 900 130 C 130 C 500 1300 40 C (MC) p = 15 kw/ C 132 C 405 105 C 675 60 C 800 Figure 3.17. Grid diagram of a complete preliminary heat-exchanger network for Example 3.2. Temperatures shifted for a minimum approach temperature of 20 C. Heat duties in kw. 425 Cooling Water 3-43

155 155 C 125 125 E1 500 kw 100 75 50 800 kw 105 C E1 1300 kw 40 kw/ C E3 675 kw 105 C 56.25 C 45 C 425 kw 25 10 kw/ C 25 C 175 175 C Enthalpy (kw) 150 125 100 75 50 25 900 kw E1 500 kw E3 675 kw 20 kw/ C 130 C 132 C 405 kw 105 C 105 C 40 C E3 675 kw 15 kw/ C 60 C 0 3-44

3.4 Network Evolution In this section, we present guidelines for optimizing preliminary heat-exchanger networks by identify loops and paths within preliminary designs and shifting heat loads away from small, inefficient heat-exchange units to create fewer, larger, more cost-effective units. We begin by relaxing the restrictions imposed on preliminary heat-exchanger networks and allowing individual exchangers to operate below minimum approach temperatures and/or transfer heat across the pinch. 3.4.1 Shifting Heat Loads around Network Loops Figure 3.19 shows a gr id diagram for a new example with a loop (bold dashed line) between heat-exchange units. To identify the loop, we begin at unit C and proceed toward the bottom of the diagram to cold stream 1. Following, the line representing cold stream 1, we reach unit F and follow the unit toward the top of the diagram to hot stream 1. Finally, we return to unit C along the line representing cold stream 1. In Figure 3.19, we shift a heat load, H, across exchangers to optimize the network design constrained only by feasible heat transfer (i.e., positive driving forces) and other practical guidelines (e.g., minimum and maximum exchanger areas). By doing so, we leave the heat balance over each stream, and the minimum heating- and cooling-utility duties, unchanged while opening a degree of freedom in the final network design. The shifting of heat loads across units within the loop can continue until the smallest unit in the loop is eliminated (unit F, 400 kw). Figure 3.20 shows a 3-45

simplified heat-exchanger network for Example 3.3 after eliminating unit F (0 kw). Note that unit C exhibits a MAT violation but he transfer remains feasible. 3-46

Steam 1150 (MC p) = 20 kw/ C 240 C 550 203.33 C 150 C 123.33 C 800 400 1400 + H - H 30 C (MC ) = 40 kw/ C p 190 C 1000 150 C 2000 70 C A B C D E F G (MC p) = 30 kw/ C 190 C 190 C + H 150 C 800 150 C 50 C 2000 400 - H 30 C (MC p) = 15 kw/ C 240 C 1150 201.67 C 550 183.33 C 1000 150 C 1400 Cooling Water Figure 3.19. Grid diagram of a preliminary heat-exchanger network for Example 3.3 with a network loop. Temperatures shifted for a minimum approach temperature of 20 C. Heat duties in kw. 3-47

Steam 1150 (MC p) = 20 kw/ C 240 C 550 203.33 C 123.33 C 123.33 C 1200 0 1400 30 C (MC ) = 40 kw/ C p 190 C 1000 150 C 2000 70 C A B C D E F G (MC p) = 30 kw/ C 190 C 190 C 1200 130 C 130 C 30 C 2000 0 30 C (MC p) = 15 kw/ C 240 C 1150 201.67 C 550 183.33 C 1000 150 C Figure 3.20. Simplified grid diagram for Example 3.3 first shown in Figure 3.19 after eliminating unit D within a network loop. Temperatures shifted for a minimum approach temperature of 20 C. Heat duties in kw. 1400 Cooling Water 3-48

3.4.2 Shifting Heat Loads along Network Paths Figure 3.21 shows a grid diagram for Example 3.4 with a path (bold dashed line) between heating steam and cooling water. To identify the path, we start at a heating utility (heater labeled unit A) and proceed toward the line representing cold stream 1. Following this line, we reach exchanger E. Continuing toward the top of the diagram, we reach hot stream 2. Traveling along hot stream 2, we reach a cooler, unit F, and finally stop at a cooling utility (cooling water). We use network paths to eliminate small, less cost-effective exchangers, heaters and coolers. In Figure 3.21, we again shift a heat load, H, along the network to optimize the network design constrained only by feasible heat transfer and other practical guidelines. However, we cannot shift heat loads along a network path and leave the heat balance over each stream, and the minimum heating- and cooling-utility duties, unchanged. For network paths, opening a degree of freedom always results in a change in the minimum heating- and cooling-utility duties. In this case, Figure 3.22 shows that we can eliminate heater F and reduce heating- and cooling-utility duties by 50 kw. However, we see a minimum approach-temperature violation in unit E. Note, heat transfer remains feasible as we have incorporated a minimum approach temperature of 20 C into the temperatures shown in Figure 3.22. 3-49

Steam 1100 405 - H (MC p) = 20 kw/ C 175 C 1000 675 91.25 C 91.25 C 925 45 C (MC p) = 40 kw/ C A B C 125 C 125 C + H 1950 76.25 C 50 - H 75 C D E (MC p) = 30 kw/ C 195 C 1100 158.33 C - H 158.33 C 1000 125 C + H 1950 60 C F G (MC p) = 15 kw/ C 152 C 405 125 C 675 80 C 50 - H 925 Cooling Water Figure 3.21. Grid diagram of a preliminary heat-exchanger network for Example 3.4 with a network path. Temperatures shifted for a minimum approach temperature of 20 C. Heat duties in kw. 3-51

Steam 1050 405 (MC p) = 20 kw/ C 175 C 1000 675 91.25 C 91.25 C 925 45 C (MC p) = 40 kw/ C A B C 125 C 125 C 2000 75 C 0 75 C D E (MC p) = 30 kw/ C 195 C 1050 160 C 160 C 1000 126.67 C 126.67 C 2000 60 C F G (MC p) = 15 kw/ C 152 C 405 125 C 675 80 C 0 925 Cooling Water Figure 3.22. Simplified grid diagram for Example 3.4 first shown in Figure 3.21 after eliminating heater F along a network path. Temperatures shifted for a minimum approach temperature of 20ÊC. Heat duties in kw. 3-52

3.5 Summary After targeting minimum heat- and cooling-utility duties, we design heat-exchanger networks that accomplish the necessary heat transfer and satisfy the stream data using the least amount of heating and cooling utilities and the fewest number of heat-exchange units. First, we design a preliminary heat-exchanger network guaranteed to accomplish the heat transfer from hot streams to cold streams (Section 3.3). Second, we simplify the preliminary network to reduce the number of heat-exchange units (e.g., heat exchangers, steam heaters and water coolers) through an evolutionary process (Section 3.4). The pinch divides the problem into subnetworks defined by the pinch temperature(s). No heat should be transferred across the pinch and that heating and cooling utilities should not be employed above and below the pinch, respectively. Beginning at the pinch and working away form the pinch, we select matches according to the design rules presented in Sections 3.3.2 and 3.3.4 to satisfy the stream data. Euler s graph theory gives us tools to evaluate heat-exchanger networks and identify the minimum number of heat-exchange units above and below the pinch temperature from the number of process and utility streams. 3-53

A general rule for matching a hot stream to a cold stream is that the capacity flowrates of streams leaving the pinch temperature (i.e., hot streams above the pinch temperature or cold streams below the pinch temperature) must be greater than or equal to the capacity flowrate of streams approaching the pinch temperature (i.e., cold streams above the pinch temperature or hot streams below the pinch temperature). When we can not strictly follow the capacity-flowrate rule for stream matching, we split streams into segments with capacity flowrates such that we can follow the capacity-flowrate rule for stream matching. We optimize preliminary heat-exchanger networks by relaxing the restrictions on preliminary networks and allowing individual exchangers to operate below minimum approach temperatures and/or transfer heat across the pinch. We shift heat within network loops to eliminate small exchangers, heaters and coolers without changing the heat balance on streams or the heating- and cooling-utility duties. We shift heat along network paths to eliminate small exchangers, heaters and coolers. This can change the heating- and cooling-utility duties. 3-54

References Linnhoff, B., and Hindmarsh, E., The pinch Design Method of Heat-Exchanger Networks, Chem. Eng. Sci., 38: 645 (1983) Linnhoff, B., Townsend, D. W., Boland, D., "A User Guide to Process Integration for the Efficient Use of Energy," IChemE UK (1982). Shenoy, U. V., Heat Exchanger Network Synthesis: Process Optimization by Energy and Resource Analysis, Gulf Publishing Company, Houston (1995). Smith, R., Chemical Process Design, McGraw-Hill, New York (1995). 3-55

Nomenclature C L ( MC p ) i Number of independent components Number of loops Capacity flowrate of stream i, kw/c N C N CU N H N HU N units S Number of cold process streams Number of cooling utilities below the pinch temperature Number of hot process streams Number of heating utilities above the pinch temperature Minimum number of units Number of units 3-56