New Developments in Measuring Low Silicon in Process Piping Using Handheld X-ray Fluorescence (XRF)

Similar documents
New Advances using Handheld XRF Technology for the Prevention of Flow-Accelerated Corrosion (FAC)

Thermo Scientific Niton Portable XRF Analyzers. Rapid, precise metal alloy identification for maximum performance and productivity

PMI in the Petrochemical

Thermo Scientific Niton XRF Analyzers Latest Developments in PMI Tools for Alloy Verification. Mark Lessard Business Development Manager

VANTA Rugged. Revolutionary. Productive.

VANTA Rugged. Revolutionary. Productive.

Extending the Capability of Portable XRF Smarter, Smaller and Faster GALM 2016

X-MET7000 Series. Why compromise? Choose Oxford Instruments. New look, new feel, new fast user interface, new reporting power

X-MET8000. Trust but verify: ensure safety and compliance at plants world-wide. Fast and reliable on-site testing for the:

X-Ray Fluorescence Measurements of Molten Aluminum Elemental Composition

ElvaX Light for Petrochemical analysis

API 570 Certification Prep API 578 Study Questions

Trust but verify: Ensure product quality at all stages of production

Positive Material Identification (PMI) by Spectrochemical Analysis The essential tool for infrastructure integrity testing in the process industries

Advancements in Handheld XRF Technology Improve Scrap Sorting and Segregation

Manufacturing and Quality Control Thermo Scientific Niton XRF Analyzers

Enhancing Aluminum Scrap Sorting with Handheld XRF

With X-MET8000 you get laboratory quality results in seconds, reducing testing costs and time.

X-MET8000 Series. Sort scrap metal accurately, fast and maximise profits

Guidelines for Avoiding Sulfidation (Sulfidic) Corrosion Failures in Oil Refineries

SEMASPEC Test Method for Metallurgical Analysis for Gas Distribution System Components

Advanced Materials Analysis with Micro-XRF for SEM

MATERIALS OF CONSTRUCTION FOR PROCESS EQUIPMENT AND PIPING SYSTEMS

X-5000 X Laboratory EDXRF with Field Portability

X-Ray Fluorescence Lab Report

X-MET8000. Trust but verify: Ensure product quality with Oxford Instruments latest handheld XRF analyser

DELTA Handheld XRF. DELTA Series. for Positive Material Identification (PMI) Fast, Nondestructive Inspections for QA/QC, Safety and Maintenance

ElvaX ProSpector in Exploration & Mining

SPECTRO XRF Report. SPECTRO xsortxhh03. Analysis of Solid Metal Samples. Summary

Sulfur Unit Equipment Problems and Low Silicon Carbon Steel Corrosion Gerald W. Wilks Lemont Refinery CITGO Petroleum

The X-MET8000 is a handheld X-ray fluorescence (XRF) analyser that delivers ultimate on-site alloy analysis for safety critical applications.

ujjbq for PMI (Positive Material Identification) Fast QC!

Bruker Elemental S1 SORTER

SECTION 2.0 REFERENCES

DELTA Handheld XRF. DELTA Series. for Positive Material Identification (PMI) Fast, Nondestructive Inspections for QA/QC, Safety and Maintenance

S1 TITAN. Innovation with Integrity. Definition of Precision. Handheld XRF

X-MET8000. Sort scrap metal fast and maximise profits with Oxford Instruments latest handheld XRF analyser. Maximise productivity and profits with:

ANALYTICAL PERFORMANCE OF A HANDHELD EDXRF SPECTROMETER WITH MINIATURE X-RAY TUBE EXCITATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Analysis of Copper and Copper Base Alloys, Using Shimadzu PDA-7000

Results are presented in Table 1. The tube was fabricated from a Type 347 and no unusual conditions were noted.

S2 RANGER LE: Analysis of Light Elements in Cement, Slags and Feldspar

Incoloy Alloy 800H/800HT (UNS N08810/088011)

Damage Occurring in FCC Hexmesh Systems Jerry Wilks Senior Corrosion & Materials Engineer Lemont Refinery

Prevent Alloy Mix-ups and Take Control of Your Supply Chain: Handheld XRF For Fast, Easy Alloy Identification and Chemistry

Analysis of inhomogeneous samples and trace element detection in alloys using QUANTAX Micro-XRF on SEM

The Convenience Stores For Metal

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. WN GLOBAL LABORATORY South Main Street Houston, TX Lester Burgess Phone:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. WN GLOBAL LABORATORY South Main Street Houston, TX Lester Burgess Phone:

The X-MET8000 is great when you need accurate on-site alloy identification and chemistry in metal recycling and scrap yards.

On site heavy metal testing and monitoring using monochromatic XRF methods

Reducing the Risk of High Temperature Hydrogen Attack (HTHA) Failures

Sample preparation for X-ray fluorescence analysis V. Fusion bead method part 2: practical applications

INCOLOY 800H / 800HT

EDXRF Portable Spectrometer

INCOLOY DATA SHEET

Standard Recommended Practice

Experimental apparatus

Quantitative X-ray Microanalysis Of Submicron Carbide Formation In Chromium (III) Oxide Rich Scale

MAXXI 6. Robust / Flexible / Total Reliability / High Precision. High performance, non-destructive, rapid coating thickness and materials analysis

Training Course Explained on API RP-578. By Don Mears Analytical Training Consultants September 19,2007

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB/T Translated English of Chinese Standard: GB/T

Portable Elemental Analysis Food safety and agriculture solutions. Innovation with Integrity. Handheld XRF

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. WN GLOBAL LABORATORY South Main Street Houston, TX Lester Burgess Phone:

Trace Elements in Petrochemical Samples: Achieving Excellent Analytical Results

SULFIDATION. From Rolled Alloys Report Number 94-72

S8 TIGER Series 2. Lab Report XRF 144. Innovation with Integrity. Accurate Quality Control of Tool Steels XRF

Electron Probe Micro-Analysis (EPMA)

Bridging new frontiers in Lab - to - Field analysis

Benchtop XRD diffractometer. MiniFlex. Analysis of materials by X-ray diffraction

MiniFlex. Analysis of materials by X-ray diffraction. Benchtop XRD diffractometer

Portable XRF for. Scrap Processing & Alloy/Metal Identification. High Speed Sorting. Light Element Analysis. Best Aluminum Analysis

In situ studies of carbon formation leading to metal dusting in syngas processes

Applied Comparison in Coating Analysis Micro-XRF and Handheld XRF

September 2012 EGO Stainless Steel Tubes - Technical Details page 1 of 9

X-MET7000 Series. Grade and trade Designed for your environment. New look, new feel, new fast user interface, new reporting power

X-ray Fluorescence Spectrometry X-ray Fluorescence Spectrometry (XRF) is a non-destructive, quantitative technique for determining chemical

Wavelength Dispersive XRF Spectrometer

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

AMERICAN PETROLEUM INSTITUTE API RP 581 RISK BASED INSPECTION METHODOLOGY BALLOT COVER PAGE. Title: MODIFICATION OF API 581 CARBONATE CRACKING

Core Analysis with the Tracer

Analysis of Cast Iron Using Shimadzu PDA-7000

These elements are in carbon steels in minimal amounts, usually less than 1%.

Metallurgy, Alloys, and Applications p. 1 Introduction and Overview p. 3 Major Groups of Copper and Copper Alloys p. 3 Properties of Importance p.

X-RAY FLUORESCENCE (XRF):

Thermo Scientific Niton XL2 100G XRF Analyzer

ATI 418 SPL alloy is readily forgeable and has fair machinability and cold formability in the annealed condition.

Handheld XRF. DELTA Series. DELTA Handheld XRF. for Environmental Inspection. The Powerful Handheld XRF for Fast, Decisive Results

SPECIFICATION FOR CONSUMABLE INSERTS

S4 T STAR Biopharmaceutical production: Rapid nutrient and contaminant analysis of cell culture media by TXRF spectroscopy

Minimize the Risk of Fire During Distillation Column Maintenance

A newly developed XRF-Sensor with high sensitivity for increased sorting efficiency.

Standard Specification for Seamless and Welded Ferritic and Martensitic Stainless Steel Tubing for General Service

STRESS CORROSION CRACKING OF STAINLESS STEELS IN HIGH PRESSURE ALKALINE ELECTROLYSERS

Failure Analysis of Cracked Reducer Flange

Expanded Coating Analysis Performance for electroless Ni Plating and Bath Analysis with Micro-XRF

SWAGELOK COMPANY FINAL,

A Case Study on Using Corrosion Analysis in Forensic Engineering. Reza Mirshams. Journal of Failure Analysis and Prevention

CALVERT GROUP SEAMLESS PIPE

ASTM Standards B127 B160 B161 B162 B163 B164 B165 B166 B167 B168 B333 B335 B407 B408 B409 B423

Transcription:

New Developments in Measuring Low Silicon in Process Piping Using Handheld X-ray Fluorescence (XRF) Presented by: Mark Lessard Business Development Manager Thermo Fisher Scientific mark.lessard@thermofisher.com

Outline Introduction- Corrosion Failures in Oil and Gas Sulfidation / Sulfidic Corrosion Elemental Analysis and Positive Material Identification (PMI) Principals of XRF Advances in handheld XRF PMI tools for Sample Preparation Interactive Demonstration of XRF Questions and Answers

Corrosion Failures in Process Piping 41% of the largest losses in the hydrocarbon processing industry resulted from failures in piping systems Corrosion is one of the leading causes of piping failures OSHA s National Emphasis Program (NEP) includes positive material identification (PMI) Recognized And Generally Accepted Engineering Practices or RAGAGEP Example RAGAGEP for PMI: API RP 578, Material Verification Program for New and Existing Alloy Piping Systems, Section 4.3 CSB, Safety Bulletin Positive Material Verification: Prevent Errors During Alloy Steel Systems Maintenance, BP Texas City, TX Refinery Fire Second International Symposium on the Mechanical Integrity of Process Piping January 1996, Houston, TX, USA

Sulfidation/Sulfidic Corrosion Two mechanisms: Hydrogen-free sulfidation H 2 /H 2 S Corrosion Result of naturally occurring sulfur compounds found in crude oil Causes accelerated corrosion in steel fittings, piping, heater tubes, and pressure vessels when the oil is heated for separation A significant cause of leaks and failures of piping systems within the refining industry

Sulfidation/Sulfidic Corrosion The rate of sulfidation corrosion is a function of many factors including Temperature Total sulfur concentration in the oil Types of sulfur compounds present Type of stream (light gas or heavy oil) Velocity Heat transfer conditions The presence or absence of hydrogen The material of construction

Using Elemental Analysis to Prevent Hydrogen Free Sulfidation Sulfidation Corrosion Increasing chromium content has a substantial effect of lowering the rate of sulfidation When carbon steel components are exposed to hydrogen-free sulfidation, those components with low Si content (<0.10%) may corrode at a significantly higher rate ( API 939-C ) H 2 /H 2 S Corrosion Carbon and low-alloy steels are ineffective in combating sulfidation below alloying levels of 12Cr-1Mo It is most common to use 18Cr-8Ni (300-series stainless) or higher alloyed steels in these environments

In-Situ Elemental Analysis of Piping Systems 2 Primary Technologies for Portable Analysis: Optical Emission Spectroscopy (OES) Technique of vaporizing sample surface and analyzing the emitted light spectra. The wavelength of the light corresponds to the elements present, while the intensity is a function of quantity of that element. X-ray Fluorescence Spectroscopy (XRF) Technique of exciting and ejecting atoms inner shell electrons with x-ray radiation and analyzing the fluorescent x-rays emitted when the atoms return to a stable state. X-ray energies emitted correspond to the individual elements, while the intensity is a function of quantity.

Pros: Accurate Handheld XRF Spectroscopy Portable - The handheld XRF analyzer weighs approximately 1.3 kg (3 lbs.) and is transported in a belt holster at the user s side Reduced sample preparation Completely nondestructive Simplicity - XRF technology is user-friendly, allowing relatively unskilled operators to participate in the inspection process Cons: Can measure elements only down to Mg on the periodic table (cannot do carbon) Stricter regulation and licensing requirements

How XRF Works Each individual element produces its own set of characteristic x-rays; the basis for qualitative analysis By counting the number of characteristic x-rays of a given element we can determine its concentration; the basis for quantitative analysis

XRF Evolution in Performance Since late 1960s, XRF has evolved through 7 generations; each generation has added new measurement capabilities as indicated by the (3) groups below Smaller, Faster, Better performance & Easier to use Today, nearly all alloys can be tested with these powerful tools. This addresses PMI Concerns in the Upstream /Downstream & Transportation Markets Measured (1) Element at a time to: >= 1.00% Chemistry in >/= 1 to 2 minutes Measured ( 16 to18 ) Elements at a time to: >= 0.01% Chemistry in </= 30 to 60 seconds Measures ( 25 to 30 ) Elements at a time to: >/= 0.003% Chemistry </= 3 to 12 seconds

New Ultra Detector Technology The Specs 25mm 2 to 45mm 2 Silicon Drift Detector (SDD) Greater surface area allows for maximization of tube current and greater overall light element X-Ray flux. Optimized voltage- By reducing voltage (with larger detector) it allows for excitation of Si without measuring Fe for improved Limits of Detection ( LOD ) Thinner window to maximize Mg-Si detection of returning fluorescence X-Ray energy Higher count rate of crucial light elements ( 400K counts per second ) The Results Next evolution in light element analysis in air (Mg, Al, Si, P, S) Detection limit for Silicon approximately 350 ppm in air. Increased sensitivity for tramp & trace elements in all alloys Even FASTER analysis of alloy and metals testing New Technology Old Technology

Auto Filters for Different Groups of Elements

Elements of Interest: Limits of Detection (LOD) Si Mn Ni Cu Cr Mo Detection Limits 210 160 100 70 35 15 Limits of detection for advanced handheld XRF analyzers in ppm (mg/kg) SDD detector, 60 seconds per filter without He purge Main Filter is for: All Elements Low Filter for: Cr, V, Ti Light Filter is For: S, P, Si, Al, Mg

Existing Piping Systems ( Retro-Active PMI ) Programs Priority for API RP 578 2 nd Edition High Temperature Sulfidic Corrosion - API RP 939-C Process Units Susceptible to Sulfidation: Carbon Steels with low silicon (0.10%) content can corrode at an accelerated rate Assets at risk from this type of degradation should apply PMI control to determine Silicon levels. (Retro-Active PMI is suggested and to follow API 578.) See API 571 and API RP 939-C See Section 7.1.4 & 5 Sample Preparation is Required Low Si-33%,PMI-18%,Specification Break-17%

Corrosion Rate of Low-Si Carbon Steel

Measuring Low Silicon in the Field Current Technologies both ( XRF/OES) have limits for the Process Temperature Range. Proper Sample preparation is required. Most material of concern for Sulfidation is Carbon Steel piping installed before 1985. This material was usually double/tripled stamped ( A53/A106/API 5LB,& A285 Plates ). Typically, fittings have higher Si content, whereas piping straight runs have less Si. Specification breaks are also a contributing factor ( 5Cr welded to 9Cr ). Other Concerns for high temperature process ( 650 F and greater ) is using 5 Cr and 9Cr with both low Cr & Si.

Sample Preparation for Low Si Typical metal alloys used in the petrochemical industry will oxidize when exposed to atmospheric conditions. This oxide coating can affect the accuracy of the reading when performing an XRF analysis and must be removed. Sample contamination can occur if you prepare with the wrong abrasive disc. It is recommended to use grinding discs made from zirconium aluminum oxide. Zirconium is a metal not commonly found in steel alloys, so trace amounts found on the surface will not negatively affect test results. As a recommended starting point, the following grit sizes are suggested: Stainless Steel 120 grit Cr/Mo Steel 80 grit Carbon & Low Alloy Steel 60 grit. Rubber backing wheel Abrasive discs Handheld, right angle grinder