Build higher and faster with FIRM-FILL CMD (corrugated steel deck) from Hacker Industries, Inc., the leader in pourable floor underlayments.

Similar documents
GYP-SPAN RADIANT, a crack-resistant gypsum concrete is designed for use over hot water tubes or electric cables in radiant heat projects.

FIRM-FILL is Hacker Industries, Inc. s underlayment solution over plywood or OSB subfloors in apartments, condos, hotels and motels.

HACKER SOUND MAT II, to create a quieter living environment while meeting demanding project specifications in multi-family construction.

FIRM-FILL SCM-400 can be installed under a FIRM-FILL Gypsum Concrete Floor Underlayment to produce an exceptional vibration isolation floor system.

When demanding consistent quality, specify FIRM-FILL SCM-250 to assist in achieving highly improved IIC sound performance in multifamily

Division : Gypsum Cement Underlayment

FIRM-FILL High Strength

PRODUCT GUIDELINES Hacker. Industries, Inc.

Floor Underlayment Selector High-Strength Flooring Solutions

USG LEVELROCK BRAND SOUND REDUCTION BOARD SRB

GYP-SPAN Radiant 6/11

Floor Underlayment Selector High-Strength Flooring Solutions

Levelrock CSD. Floor Underlayment. The Lightweight Flooring Solution

A. Description of Work: Work of this section includes self leveling underlayment for interior finish flooring but is not limited to, the following:

Triton BK Backer Board & Tile Underlayment

SECTION GYPSUM CEMENT UNDERLAYMENT RECOMMENDED SPECIFICATION FOR DURA-CAP FLOOR UNDERLAYMENT OVER EXTRUDED OR EXPANDED POLYSTYRENE FOAM

Acoustic Treatment

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council

USG Tile & Flooring Solutions. Lightweight cement board. Easy to cut and fasten. Faster installation USG DUROCK BRAND CEMENT BOARD INSTALLATION GUIDE

Multifamily, Commercial, Single-Family, Renovation. A Reputation You Can Stand On

CGC DUROCK BRAND CEMENT BOARD WITH EDGEGUARD

Lightweight, superior performance. for multiple applications. MICORE Brand. Mineral Fiber Board

Triton WP Waterproof Membrane

A. Section includes hydraulic-cement-based, polymer-modified, self-leveling underlayment for application below interior floor coverings.

Kolorines Glass Mosaic Tiles Project Specification

DIVISION: FINISHES SECTION: ACOUSTIC TREATMENT REPORT HOLDER: ECORE INTERNATIONAL, INC.

LISTING INFORMATION OF International Beams - IB Series Joists SPEC ID: 27316

USG DUROCK BRAND SURFACE PRO SELF-LEVELING UNDERLAYMENT

A. Prepare formwork shop drawings using qualified professional engineer. Include detail of fabrication, assembly, and support of formwork.

CGC FIBEROCK BRAND AQUA-TOUGH AR INTERIOR PANEL

Chapter 2. Basic practices. Topics. 7 Basic practices. Notes. 2.5 Existing flooring and adhesive residue Job site conditions 8

USG DUROCK BRAND FLOOR PREP PORTFOLIO BROCHURE PATCHES AND SKIM COATS SELF-LEVELING UNDERLAYMENTS MOISTURE MITIGATION PRIMER-SEALERS

Normal, Medium And High Density Fireproofing Materials

Stark Truss Company, Inc. Revised December 14, 2018

FIRE-HALT SEALANT/SETTING COMPOUND

PLYCEM SX20/20 PREMIUM STRUCTURAL SUBFLOORING PLYCEM SX20/20 PREMIUM STRUCTURAL SUBFLOORING

FIRE & SOUND IN MULTIFAMILY FLOORS DESIGN CONSIDERATIONS

Triton DCI Decoupling Mat

ARDEX GUIDE SPECIFICATION ARDEX GS-4 Self-Leveling Repair Underlayment for Distressed Gypsum and Wood Subfloors

Design No. L565. Design No. L565

Submittal Transmittal

The original. insulation.

USG DUROCK BRAND NE FLOOR PATCH

Suggested Specification for Tri-Patch Versatile Concrete Patching Compound

ARDEX GUIDE SPECIFICATION ARDEX K 22 F High Flow, Fiber Reinforced, Self-Leveling Underlayment

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIRESTOPPING REPORT HOLDER: PASSIVE FIRE PROTECTION PARTNERS

RESILIENT CORK TILE 3 PART SPECIFICATION #Z 624

SECTION A. Schönox AP- Synthetic Gypsum Self Leveling Underlayment. B. Schönox VD-Primer for porous substrates

PLYCEM SX20/20 MODULAR BUILDING INDUSTRY FLOOR SYSTEM PLYCEM SX20/20 MODULAR BUILDING INDUSTRY FLOOR SYSTEM

CGC SECUROCK BRAND SHEATHING

ARCHITECTURAL GUIDE SPECIFICATIONS - DESCRIPTIVE

USG Tile & Flooring Solutions. USG DUROCK BRAND CEMENT BOARD WITH EDGEGUARD Installation Guide

FIRE & SOUND MANUAL ARCHITECT VERSION 4.16

FIRE & SOUND MANUAL ARCHITECT VERSION 6.17

The GlasRoc Shaftliner Type X advantage...

RESILIENT FLOORING: Select Step Wood

USG DUROCK BRAND ULTRACAP PRO SELF-LEVELING UNDERLAYMENT. USG Performance Flooring Solutions SUBMITTAL SHEET

SECTION INSULATION. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

TECHNICAL INFORMATION SCREED

CON-DEK ICC-ES ESR-2097 SYSTEM

Self-Leveling Repair Underlayment for Distressed Gypsum and Wood Subfloors

LISTING INFORMATION OF Mitek Design No. MCI/WI SPEC ID: MiTek Canada, Inc. 100 Industrial Road Bradford, ON L3Z 3G7 Canada

USG LEVELROCK BRAND 4500 PRE-SANDED FLOOR UNDERLAYMENT

Action QuickCourt R Modular Athletic Flooring

VERSAROC CEMENT BONDED PARTICLE BOARD SUBFLOORING VERSAROC CEMENT BONDED PARTICLE BOARD SUBFLOORING

Section Cementitious underlayment

Desco Granite Flooring Specifications

ICC ES SYSTEM SYSTEM. Trusted DIVISION: 07 SECTION: AND FINISH REPORT HOLDER: ICC-ES Evaluation. Reissued 08/2016.

RESILIENT FLOORING: Hot and Heavy - Secoya

MEMBRANE 510/510R Low VOC Flexibilized, Urethane Membrane mils

ASH GROVE KOLORSTONE BROOMCOAT MIXING KIT. Spec Sheets Contents: Kolorstone Broomcoat Mixing Spec Sheet Kolorflex Admixture Spec Sheet

UltraLight Panels. Submittal Sheet Sheetrock Brand

Rubber Flooring Installation Guidelines

Alkalinity Control Formula Primer PRODUCT DESCRIPTION. Reduces sweating of the concrete surface.

Sound Control Solutions in Floor/Ceiling Assemblies

SECTION RESINOUS FLOORING

High-performance structural cement-bonded particle board (CBPB)

ARDEX GUIDE SPECIFICATION ARDEX FEATHER FINISH Self-Drying, Cement-Based Finish Underlayment

Boise Cascade Company Revised June 25, 2018

SECTION Arisfor WallGuard

EcoTouch Insulation with PureFiber Technology

ARDEX GUIDE SPECIFICATION ARDEX SD-M Designer Floor Finish

COMMERCIAL BUILDING APPLICATIONS

Foamed-in-place insulation Sprayed insulation. Spray Foam Insulation for Residential Building Envelope Insulation

RAY-CORE Structural Insulated Roof and Wall Panels

SECTION mil thickness REINFORCED LIQUID-APPLIED WATERPROOFING

FOR: CEMCO - California Expanded Metal Products Co. Sound Transmission Loss Test

Floor Insulation Underlayment Section Sound Control Matting

GenieMat FF. Floating Floor Systems for Airborne & Impact Sound and Vibration Isolation. It s not magic, it s engineering. Impact Sound Control

PinkWood Ltd. Revised September 29, 2017

SECTION mil thickness COLD FLUID-APPLIED WATERPROOFING

DIVISION 3 - CONCRETE Section Concrete Toppings Concrete Resurfacing Concrete Rehabilitation

DIVISION: FINISHES SECTION: ACOUSTIC TREATMENT REPORT HOLDER: HOMASOTE COMPANY

CertainTeed. Tile Backer

TechLevel 125 Deep Pour Self-Leveling Underlayment

SECTION mil thickness REINFORCED LIQUID-APPLIED WATERPROOFING

Powerhold 850 Advanced Skim Coat

ARDEX A 38 MIX Rapid Set, Premixed Screed

Section Shotcrete

SECTION SPRAY FOAM INSULATION

Transcription:

Build higher and faster with FIRM-FILL CMD (corrugated steel deck) from Hacker Industries, Inc., the leader in pourable floor underlayments. Designed for use in multi-family, commercial and institutional buildings with light-gauge steel framing and a corrugated steel deck, FIRM-FILL CMD is a lightweight, high-strength gypsum concrete floor underlayment. Installed at 1 above the top of the flutes (1-9/16 total), FIRM-FILL CMD reduces dead loads, which can significantly lower costs. The lightweight solution for fast-track construction UL fire rated design floor/ceiling assembly G565, G568; 1, 1½ or 2 hour fire ratings Applied directly over primed corrugated steel deck Minimum compressive strength 3500 psi (24 MPa) Installed by trained Licensed Applicators

1 1 2 12 2 12 13 6 13 9 6 9 10 10 1 - FLOOR COVERING / 2 - FIRM-FILL CMD GYPSUM CONCRETE UNDERLAYMENT / 3 - FIRM-FILL SCM OR HACKER SOUND MAT / 4 - FIRM-FILL CMD GYPSUM CONCRETE UNDERLAYMENT TO FILL FULTES / 6 - BATT INSULATION / 9 - RESILIENT CHANNEL / 10 - GYPSUM WALLBOARD / 12-22 MSG GALVANIZED CORRUGATED STEEL DECK / 13-16 MSG GALVANIZED, CHANNEL-SHAPED, 9-1/4 (231MM) MIN. STEEL JOIST 0 psi 1000 psi 2000 psi 3000 psi 4000 psi 5000 psi 6000 psi 2016 Hacker Industries, Inc. FIRM-FILL and the associated logos are trademarks of Hacker Industries, Inc., Newport Beach, CA. Firm-Fill Gypsum Concrete Firm-Fill 2010+ Firm-Fill 3310+ Firm-Fill High Strength Use in coldformed steel construction with a corrugated steel deck Requires dryin (building must be fully enclosed before installation) 1200-2000 psi 2000-3200 psi 3000-3900 psi Gyp-Span Radiant 2000-3200 psi 2500-3800 psi 1 > FLUTES 2 LIFT Requires 1 over top of flutes; max. lift depth of 2 Not a wear surface; requires finished floor covering >3500 Provides compressive strengths over 3500 psi (24.1 MPa) L/360 Deflection must not exceed L/360 live or dead load Hacker Industries, Inc. Architect Binder Firm-Fill CMD 2017 Firm-Fill 4010+ Firm-Fill CMD True-Screed CLU Install with Hacker Sound Mat or FIRMFILL SCM for additional isolation Subfloor must be protected by vapor barrier if installed above crawl space 4000-5200 psi min. 3500 psi up to 6000 psi Contributes points to LEED project certification One component of an effective sound & fire control system Installed by Hacker Industries trained Licensed Applicators Wear appropriate personal protective equipment 71

TECHNICAL DATA PROPERTIES ASTM Weight Minimum 12.8 lb/ft² (62.47 kg/m²) at 1-9/16 (40 mm) C472 M Thickness 1 (25 mm) above the top of the flutes Compressive Strength Minimum 3500 psi (24.1 MPa) C472 M Fire Hazard Classification Flamespread index 0: Fuel contribution 0; Smoke density 0 E84 Sand 1/8 (3 mm) or less washed plaster or masonry sand C33 Benefits For use in cold-formed steel frame construction with a corrugated steel deck Install over a FIRM-FILL SCM or Hacker Sound Mat for additional sound isolation Lightweight solution for fast-track construction Rapid set time; can be walked on in 2 hours Helps contribute points to LEED project certification Creates a flat, durable surface for finished floor coverings Installed only by trained Licensed Applicators across North America Product Description FIRM-FILL CMD is designed for use in cold-formed steel frame buildings with a corrugated steel deck. FIRM- FILL CMD provides minimum compressive strengths of 3500 psi (24.1 MPa). FIRM-FILL CMD is mixed on the job site with local sand (per ASTM C33) and water to create a lightweight slurry. A 1 (25 mm) application is required above the top of the flutes. Maximum thickness is 2 (51 mm) in one lift. For residential and light commercial construction, FIRM-FILL CMD is a cost-effective method to build higher and faster. FIRM-FILL CMD creates a smooth, hard surface for finished floor coverings, while offering exceptional compressive strengths matched with superior acoustical control and fire resistance properties. For added sound isolation, use FIRM-FILL CMD with a FIRM-FILL SCM or Hacker Sound Mat. Limitations When considering the use of this floor system, a licensed structural engineer shall first evaluate the building loads and framing system to determine whether this corrugated steel deck system is appropriate. FIRM-FILL CMD is not a structural element and does not provide any contribution to the floor diaphragm. The corrugated steel deck shall be designed to address all floor diaphragm requirements and must conform to the Steel Deck Institute Standards. Reference SDI Manual of Construction with Steel Deck. For additional requirements, contact Hacker Industries, Inc. Shall not be used in exterior locations, below grade or where continuous exposure to moisture is likely. Shall not be used as a wear surface; must be covered by a finished floor covering. Structure shall be designed so that deflection does not exceed L/360 live or dead load. Certain floor coverings, such as marble, limestone, travertine and wood, may have more restrictive deflection limits. Consult the appropriate floor covering manufacturer for recommendations. No single application of FIRM-FILL CMD shall exceed 2 in depth. FIRM-FILL CMD is one component of an effective sound and fire control system. Care must be taken in the installation of all components to assure the ultimate design performance. Published acoustical and fire system tests were conducted under controlled laboratory or field conditions and reflect results applicable only to those specific assemblies. 72 Hacker Industries, Inc. Architect Binder Firm-Fill CMD 2017

Installation Before, during and after the installation of FIRM-FILL CMD, the building must be enclosed and the temperature maintained at a minimum of 50 F (10 C). Prior to the installation of FIRM-FILL CMD, the subfloor shall be structurally sound (L/360) and be broom cleaned, dry and free from oil, grease, parrafin, laitance, wax or other contaminants. Prime the corrugated steel deck with FIRM-FILL CMD Primer per recommended specifications before installing underlayment. Adequate ventilation shall be provided by the General Contractor (GC) to ensure proper drying of FIRM-FILL CMD. If necessary, the GC shall provide mechanical ventilation. Depending on thickness and drying conditions, the underlayment should dry within 10 to 14 days. To avoid potential problems during the drying process, the GC shall consult Hacker Industries, Inc. s Drying Conditions Flyer and information contained on Hacker Industries, Inc. s website for additional information concerning drying of this product. After installation, temporary wood planking shall be placed by the GC wherever the floor underlayment will be subject to wheeled or concentrated loads. Finished floor coverings can be installed when the FIRM-FILL CMD is completely dry. Consult flooring contractor for recommended procedures to test for dryness and acceptable levels of moisture. Reference Hacker Industries, Inc. s Guidelines for Installing Finished Floor Coverings. This guideline is not a warranty and shall be used as a guideline only. See ASTM F2419. Product Data Approximate Compressive Strength per ASTM C472 Modified: Approximate Dry Density (aggregated): Minimum 3500 psi* (13.8 to 22.8 MPa) 107 to 120 pcf *Note: Compressive strengths published herein were achieved under controlled laboratory conditions. Actual field results may differ due to environmental conditions, regional sand variations, or inconsistent proportioning of field-applied water, sand and Hacker Floor Underlayment, as well as differences in mixing/pumping equipment. Compliance ICC-ES ER-4147 City of Los Angeles Research Report No. 24540 FHA-HUD MR 1255 Tile Council of North America (F180, F200, RH111, RH122) Sound Test & UL Fire Rated Designs PURPOSE STATEMENT/DISCLAIMER These guidelines are designed to provide the architectural and building communities with detailed performance data on Hacker Industries, Inc. s comprehensive portfolio of sound attenuation tests and UL Fire Rated Designs. The tests for the assemblies included in these guidelines were conducted in a laboratory setting per ASTM C177, E84, E90, E492 and E2179. These guidelines are not warranties and should be used as guidelines only. The architects and general contractors recommendations supersede these guidelines. Field performance may vary. Subject to express Warranty stated on Hacker Industries, Inc. s website. Hacker Industries, Inc. regularly performs acoustical and fire (UL) testing to ensure performance standards for our products. Firm-Fill gypsum concretes, including Firm-Fill CMD, were tested acoustically with the following floor assemblies and performed as noted. Hacker Industries, Inc. Architect Binder Firm-Fill CMD 2017 73

Subfloor Topping Sound Mat 1 (25 mm) 1/4" FIRM- (6 mm) FILL CMD Hacker Gypsum Sound Concrete Mat II Firm-Fill CMD Corrugated Steel Deck Subfloor Insulation Truss Ceiling Isolation 14 mm 3-1/2" deep (89 mm) 22 msg unfaced galvanized fiberglass corrugated batt fluting insulation steel decking Contributes points to LEED certification. Dietrich Clark Dietrich RCSD Resilient Channel Ceiling Finish Sound Rating 1 layer 5/8" (16 mm) type C gypsum board 13 mm Quarry Tile Flooring Over 10 mm QT4010 13 mm Quarry Tile Flooring Over 10 mm QT4010 STC IIC Report # 61 -- 5008041 -- 58 7008100 Steel Deck Steel Joist UL Fire Rated Designs G230, G516, G524, G553, G561, G565, G566, G568, G587, G594, G595 L524, L527, L539, L543, L549, L551, L552, L564, M505, M511, M513, M515, M534 74 Hacker Industries, Inc. Architect Binder Firm-Fill CMD 2017

Related Products FIRM-FILL SCM sound control mats, FIRM-FILL CMD Primer, Hacker TopCoat SP and Hacker Floor Sealer are available for use with FIRM-FILL CMD Floor Underlayment. Contact Hacker Industries, Inc. at (800) 642-3455 or info@hackerindustries.com for more information. Warranty Subject to express warranty stated on Hacker Industries, Inc. s website. Submittal Approvals Project Name Contractor/Architect Signature Date PRODUCT INFORMATION See www.hackerindustries.com for current recommended product specifications and literature. WARNING When mixed with water, this product hardens and becomes extremely hot. DO NOT attempt to make a cast enclosing any part of the body using this material. Failure to follow these instructions may cause severe burns that may require surgical removal of affected tissue or amputation of limb. Portland cement is strongly alkaline. Direct contact can be corrosive and cause severe damage or chemical burns to eyes and wet, moist skin. Avoid contact with eyes and skin. Wear protective glasses and clothing. If eye contact occurs, immediately flush thoroughly with water for 30 minutes and seek medical advice. Inhalation of dust may be corrosive or cause chemical burns or irritation to nose, throat and respiratory tract. Avoid breathing dust. Use a NIOSH/MSHA-approved dust respirator. Wash thoroughly with soap and water after use. Do not ingest. If ingested, call a physician. Product safety, call (800) 642-3455. KEEP OUT OF REACH OF CHILDREN. TRADEMARKS FIRM-FILL, GYP-SPAN, Let Our Products Floor You and the associated logos are trademarks of Hacker Industries, Inc. LEED is a registered trademark of the U.S. Green Building Council. WARRANTY HACKER INDUSTRIES, INC. SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, DIRECTLY OR INDIRECTLY SUSTAINED, NOR FOR ANY LOSS CAUSED BY APPLICATION OF THESE GOODS NOT IN ACCORDANCE WITH CURRENT PRINTED INSTRUCTION OR FOR OTHER THAN THE INTENDED USE. OUR LIABILITY IS EXPRESSLY LIMITED TO REPLACEMENT OF DEFECTIVE GOODS. ANY CLAIM SHALL BE DEEMED WAIVED UNLESS MADE IN WRITING TO US WITHIN 30 DAYS FROM DATE IT WAS, OR REASONABLY SHOULD HAVE BEEN, DISCOVERED. SAFETY FIRST Follow good safety/industrial hygiene practices during installation. Wear appropriate personal protective equipment. Read specs, MSDS and literature prior to specification and installation. Hacker Industries, Inc. Architect Binder Firm-Fill CMD 2017 2017 Hacker Industries, Inc., Newport Beach, CA. 75