SIDEWALK & RAILING REPLACEMENT BOARD OF ED BUILDING

Similar documents
City of Des Moines. Permit and Development Center 602 Robert D Ray Drive Des Moines, IA Phone: Fax:

APPLICATION NUMBER:, TAX MAP KEY: STREET ADDRESS:, PRPOJECT: APPLICANT:, PHONE NO: MAILING ADDRESS:, FAX NO:

Document G808. Project Data CONSTRUCTION DOCUMENTS DATE IDENTIFICATION DESIGN DEVELOPMENT DATE IDENTIFICATION INITIAL INFORMATION DATE IDENTIFICATION

Applying the Building Code During Design

City of Pekin- Zoning and Inspections Department 111 S. Capitol Street, Pekin, Illinois (309)

LEAD DESIGN PROFESSIONAL:

2018 APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS (EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES)

Name of Project: Address: Zip Code Owner/Authorized Agent: Phone # ( ) - Owned By: Select one Code Enforcement Jurisdiction: Select one

Name of Project: Address: Zip Code Owner/Authorized Agent: Phone # ( ) - Owned By: Select one Code Enforcement Jurisdiction: Select one

CODE COMPLIANCE PLAN REVIEW PROCEDURES

The Building Codes A.R.E. Building Design and Construction Exam Prep

2018 APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS (EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES)

NOTE: For construction other than new commercial or additions (renovations), only those areas below describing the scope of work will be applicable.

Design and Construction AN ISO 9001:2008 CERTIFIED ORGANIZATION

Building Codes and Ordinances ARC 227

Code Requirements for Existing Buildings. R. W. Sullivan, Inc. 529 Main St., Suite 203 Charlestown, MA (617)

Schedule A. a representative appointed from among persons nominated by the Nova Scotia Accessibility Advisory Board.

Following contains common verbiage found in major model building codes and has been edited for the purpose of inclusion on this CD.

General Building Information

* RESIDENTIAL PLAN REVIEW *

UCC Permit Application Procedures

Worksheet for Commercial Building Planning

One & Two Family Residential ADDITIONS

Code Requirements for Existing Buildings. R. W. Sullivan, Inc. 529 Main St., Suite 203 Charlestown, MA (617)

SPARTANBURG COUNTY BUILDING CODES DEPARTMENT

COMMUNITY & DEVELOPMENT SERVICES 840 Northgate Drive, Richland, WA Phone: Fax:

One & Two Family Residential NEW CONSTRUCTION Plan Review Checklist

What is a Won-Door FireGuard Door?

This worksheet must be signed by the architect or engineer of record for the entire project for commercial or mixed-use buildings.

City of Walnut Creek Development Review Services 1666 N. Main Street, Walnut Creek, CA (925) phone (925) fax

FIRE AND SMOKE PROTECTION FEATURES

COMMERCIAL TENANT IMPROVEMENT PERMIT APPLICATION

2007 Title 24 Accessibility Code Updates and ADA Issues

SECTION 702 DEFINITIONS

DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS. Public Safety Services ADA-ABA COMMENT ASSISTANCE GUIDE

4. Number of drawings required: ( ) Locations of nearest streets

A minimum of 25% of any money spent upgrading areas of primary function shall be devoted to ADA upgrades. Existing non-compliant areas include:

Uniform Building Code For Head-of-Wall, Vertical Shaft Walls and Wall Backing Excerpts from the 1997 Uniform Building Code

Adult Family Home Inspections

FS , 712, 713, 714

CHAPTER 34 EXISTING BUILDINGS

Architect and Engineer: Friar Associates inc.

Commercial Remodel Permit

HERMIT S REST GRAND CANYON NATIONAL PARK BUILDING CODE REVIEW

Code Compliance for Fire Resistance-Rated Assemblies in Light-Frame Buildings. John Buddy Showalter, PE VP, Technology Transfer American Wood Council

Minimum Requirements for Residential Occupancy Codes and FAQs

Building Code 8 th Edition

Common Plan Review Rejection Reasons

CITY OF COOPER CITY BUILDING DEPARTMENT

BUILDING DIVISION 120 Malabar Road, S.E., Palm Bay, FL Phone: (321) Fax: (321)

CALIFORNIA BUILDING PLANS EXAMINER CONTENT OUTLINE 01. GENERAL ADMINISTRATION 3 % Project Administration 3%

INTERNATIONAL CODE INTERPRETATIONS

Common Plan Review Rejection Reasons

Code Compliance for Fire Resistance-Rated Assemblies in Light-Frame Buildings

South Windsor Public Schools. Elementary School Facilities Existing Condition Survey & Master Plan. Executive Summary 10/22/13

2012 Code Update Training

AIR CRE Industrial Building Standards

STRUCTURAL ABBREVIATIONS S-001 GENERAL NOTES CONCRETE MASONRY NOTES DESIGN NOTES SOF NSWG-10 UAS SUPPORT FACILITY FY 2016 MILCON P-225

RESIDENTIAL BUILDING PERMIT APPLICATION ( MINIMUM Building Requirements-Page 6)

Town of Pawling Residential Building Permit Application

ORDINANCE. APPROVED EMERGENCY: (Yes) (No) VETOED: Date

CODE ANALYSIS REPORT SECOND FLOOR

Code Compliance for Fire Resistance-Rated Assemblies in Light-Frame Buildings

Tenant Fit-Out for PLCB / Waynesboro Mall

Coastal LINCOLN VOLVO OF NEW BERN RENOVATIONS. Architecture NEW BERN, NORTH CAROLINA. Coastal Architecture. Coastal Architecture,

&02.1. Level 3 Alterations. Level 3 Alterations shall comply with Sections & and &

COMMERCIAL BUILDING PLAN REVIEW CHECKLIST

CITY OF CALABASAS RESIDENTIAL PLAN REQUIREMENTS 1 OF 5 8/2017 PLAN INFORMATION

INSTRUCTIONS FOR COMPLETING THE BUILDING PERMIT APPLICATION FOR COMMERCIAL PROJECTS

Town of Pawling Residential Building Permit Application

0103 Plan Reading 4% Read plans to verify the project conforms with the code, approved plans, and construction documents.

City of Westerville Guide to Commercial Inspections

EFFECTIVE USE OF THE IBC/CBC

FIRE AND SMOKE PROTECTION FEATURES

Accessible Means Of Egress

CALIFORNIA COMMERCIAL BUILDING INSPECTOR CONTENT OUTLINE 01. GENERAL ADMINISTRATION 6% Project Administration 1%

Company Overview. Significant Code Changes Massachusetts State Building Code 9 th Edition (2015 International Code)

FRAMING INSPECTION GENERAL

PENNSAFE BUILDING INSPECTION SERVICES LLC Deck and Roof Cross Section Submittal

Shaft Wall Solutions for Wood-Frame Structures. Ricky McLain, PE, SE WoodWorks Wood Products Council Boston & Waltham Workshops, December 6 & 7, 2017

CITY OF DANA POINT WINDOW REPLACEMENTS FOR R-3 B030 WINDOWS

Minimum Requirements For One & Two Family Structures FBC 6 th Edition (2017)

FIRE AND SMOKE PROTECTION FEATURES

PENNSAFE BUILDING INSPECTION SERVICES LLC PERMIT APPLICATION

Pulaski County, Virginia

Building Division Informational Handout

SPACE TYPE: OUTSIDE PARKING (STRUCTURE)

Chapter 4-16 SPECIAL DESIGN STANDARDS FOR TYPE V CONSTRUCTION

Administrative Changes

VERTICAL OPENINGS STUDY GROUP REPORT TO CTC MEETNG CHICAGO, IL - OCTOBER 13-14, 2011 CODE CHANGES

Shaft Wall Solutions for Wood-Frame Structures. Ricky McLain, PE, SE WoodWorks Wood Products Council Charlotte WSF, November 2, 2017

The Building Code for Rookies

Fire Inspection and Code Enforcement, 7 th Edition. Chapter 6 Building Construction: Components Inspector II

RESIDENTIAL BUILDING PERMIT GUIDE FOR MULTI-FAMILY DWELLINGS

Bonadio Residence. Renovations to Existing Dwelling: new kitchen. 23 Albert Street Waltham, MA. Addition to existing structure.

RESIDENTIAL NEW CONSTRUCTION PLAN REVIEW CHECKLIST

Contractor/Owner initials are verification that items #1 and #2 and items (a) thru (g) above are included in the submitted plan/drawing.

CODE 101 How To Read The California Building Code

Minnesota Healthcare Engineers Association, Fall Conference. Bob Dehler, P.E. Engineering Program Manager September 14, 2017

WCU ALUMNI TOWER MASONRY & ENVELOPE REPAIRS

Transcription:

PROJECT: 25 E 5 S SALT LAKE CITY, UTAH 84111 CODE ANALYSIS APPLICABLE CODES 675 E. 5 S. Suite 4 DFCM PROJECT NUMBER: 182782 DFCM CONTRACT NUMBER: 18793 STRUCTURAL ENGINEER: REAVELEY ENGINEERS + ASSOCIATES 675 East 5 South, Suite 4 Salt Lake City, Utah 8412 PH#: (81) 4863883 FAX: (81) 485911 CONTACT: Mark Thimm, PE, LEED AP DRIVEWAY 5 SOUTH (CESAR E. CHAVEZ BLVD) FOOTNOTES: 1) In case of conflict with the U.S. Department of Justice Federal Registers Parts through ADA Guidelines and specific reference to the International Building Code Accessibility Chapters, the more restrictive requirement shall govern. 2) Additional Code Information shall be provided at the discretion of the Building Official for Complex Buildings. Including, but not limited to: a) High Rise Requirements. b) Atriums. c) Performance Based Criteria. d) Means or Egress Analysis. e) Fire Assembly Locator Sheet. f) Exterior and Interior Accessibility Route. g) Fire Stopping, Including Tested Design Number. SYMBOL LEGEND ELEVATION REFERENCE DETAIL NUMBER SHEET NUMBER DETAIL REFERENCE CUT DETAIL NUMBER SHEET NUMBER DETAIL REFERENCE DETAIL NUMBER SHEET NUMBER NORTH NORTH ARROW MATCH LINE GRID LINE BREAK LINE CENTER LINE REVISION DESIGNATION REVISION NUMBER REVISION CLOUD Special Use and Occupancy (e.g. High Rise, Covered Mall): B. Seismic Design Category: C. Type of Construction (circle one): G: I: J: International Building Code International Mechanical Code International Fuel Gas Code International Plumbing Code International Fire Code International Energy Conservation Code Change in Use: Yes No X Mixed Occupancy: Yes X No A B North: South: East: West: F: Sprinklers: Required: Provided: Yes H: Actual Area Tabular Area: b) Sum of the Ratio Calculations for Mixed Occupancies: Actual Area Allowable Area _< c) Total Allowable Area for: 1) One Story: 2) Two Story: A (2) 3) Three Story: A (3) A E. Mixed Occupancies: Existing Nonseparated Uses: Existing Area Modifications: a a 1 B Year 215 A. Occupancy and Group: Civic Admin. B Number of Stories: 3 Building Height: A National Electrical Code Uniform Code for Building Conservation ADA Accessibility Guildelines Design Wind Speed: D. Fire Resistance Rating Requirements for the Exterior Walls based on the fire separation distance (in hours): Type of Sprinkler System (IBC 93.3.1) Existing a) d) Unlimited Area Building: Yes No Code Section: B HT per Floor (square feet): (table 53): A B Year 13 S GORDON LANE SALT LAKE CITY, UT 8417 DRAWING INDEX K. Fire Resistance Rating Requirements for Building Elements (hours). Element Hours Assembly Listing Element Hours Assembly Listing SHEET INDEX PAGE PARKING LOT TITLE SHEET & SITE PLAN GENERAL STRUCTURAL NOTES SPECIAL INSPECTIONS, TESTING, & OBSERVATIONS SPECIAL INSPECTIONS, TESTING, & OBSERVATIONS CONT. GROUND LEVEL PLAN ENLARGED SOUTH BRIDGE PLAN & SECTIONS ENLARGED ENTRY PLAN ELEVATIONS GI1 SE1 SE2 SE3 SF11 SF12 SF13 SF21 Exterior Bearing Walls Interior Bearing Walls Exterior NonBearing Walls Structural Frame Partitions Permanent Fire Barriers L. Design Occupant Load: Exit Width Required: Exit Width Provided: M. Minimum Number of Required Plumbing Facilities: Floors Ceiling Floors Roofs Ceiling Roofs Exterior Doors and Windows Shaft Enclosures Fire Walls Fire Partitions Smoke Partitions TITLE SHEET & SITE PLAN BOARD OF EDUCATION BUILDING SITE PLAN NORTH GUARDRAIL DETAILS HANDRAIL DETAILS CONCRETE REPAIR DETAILS SCHEDULES SF51 SF52 SF53 SF61 a) Water Closets: b) Urinals: c) Lavatories: d) Bath Tubs or Showers: e) Drinking Fountains: Service Sinks: GI1

13 S GORDON LANE SALT LAKE CITY, UT 8417 ABBREVIATIONS 675 E. 5 S. Suite 4 12/1/217 GENERAL STRUCTURAL NOTES 12/4/217 SE1

13 S GORDON LANE SALT LAKE CITY, UT 8417 675 E. 5 S. Suite 4 12/1/217 SPECIAL INSPECTIONS, TESTING, & OBSERVATIONS 12/4/217 SE2

13 S GORDON LANE SALT LAKE CITY, UT 8417 675 E. 5 S. Suite 4 12/1/217 SPECIAL INSPECTIONS, TESTING, & OBSERVATIONS CONT. SE3

1 GROUND LEVEL PLAN 2 3 4 5 6 7 NORTH 8 A B C D E F G H J K SHEET NOTES SHEET LEGEND ALTERNATE NOTES 13 S GORDON LANE SALT LAKE CITY, UT 8417 675 E. 5 S. Suite 4 12/1/217 GROUND LEVEL PLAN SF11

ENLARGED SOUTH BRIDGE PLAN SOUTH BRIDE SECTION NORTH SHEET NOTES SHEET LEGEND ALTERNATE NOTES SOUTH BRIDE SLAB REPLACEMENT SECTION @ DOOR SOUTH BRIDE SLAB REPLACEMENT SECTION @ STAIRS 13 S GORDON LANE SALT LAKE CITY, UT 8417 675 E. 5 S. Suite 4 12/1/217 ENLARGED SOUTH BRIDGE PLAN & SECTIONS SF12

ENLARGED ENTRY PLAN NORTH SHEET NOTES SHEET LEGEND ALTERNATE NOTES 13 S GORDON LANE SALT LAKE CITY, UT 8417 675 E. 5 S. Suite 4 12/1/217 ENLARGED ENTRY PLAN SF13

NORTH ELEVATION EAST ELEVATION SOUTH ELEVATION WEST ELEVATION 13 S GORDON LANE SALT LAKE CITY, UT 8417 675 E. 5 S. Suite 4 12/1/217 ELEVATIONS SF21

675 E. 5 S. Suite 4 12/1/217 TYPICAL GUARDRAIL ELEVATION @ MASONRY WALL TYPICAL GUARDRAIL ELEVATION @ WALL END 13 S GORDON LANE SALT LAKE CITY, UT 8417 GUARDRAIL ELEVATION ON EAST SIDE OF BUILDING GUARDRAIL ELEVATION ON SOUTH SIDE OF BUILDING RAILING EXPANSION JOINT DETAIL GUARDRAIL DETAILS TYPICAL POST DETAIL IN 8" WALL TYPICAL POST DETAIL IN 12" WALL TYPICAL POST DETAIL IN 12" WALL TYPICAL POST DETAIL IN 12" WALL SF51

RAMP HANDRAIL ELEVATION RAMP HANDRAIL ELEVATION RAMP HANDRAIL ELEVATION RAMP HANDRAIL ELEVATION RAMP HANDRAIL ELEVATION RAMP HANDRAIL ELEVATION 13 S GORDON LANE SALT LAKE CITY, UT 8417 675 E. 5 S. Suite 4 12/1/217 HANDRAIL DETAILS SF52

CONCRETE REPAIR STEPS CONCRETE REPAIR STEPS CONCRETE REPAIR STEPS CONCRETE REPAIR NOTES CONCRETE REPAIR STEPS CONCRETE REPAIR NOTES 675 E. 5 S. Suite 4 12/1/217 MINOR CONCRETE DELAMINATION (DEPTH: 1/2" TO 11/2") REINFORCING PREPARATION STEPS (VERTICAL) PREPARATION OF DETERIORATED EXISTING REINFORCEMENT MODERATE CONCRETE DELAMINATION (DEPTH: 1" TO 3") CONCRETE REPAIR STEPS TYPE A1 CONCRETE REPAIR.1".25" (EPOXY INJECTION) (VERTICAL) TYPE D CONCRETE REPAIR (1"2.1/2" DEEP) CONCRETE EDGE REPAIR RECESS EXISTING ANCHORS & EMBEDS RECESS EXISTING ANCHORS & EMBEDS 13 S GORDON LANE SALT LAKE CITY, UT 8417 DETAIL "A" CONCRETE REPAIR DETAILS TYPICAL ROUT & SEAL CRACK OR JOINT COVE SEALANT JOINT DETAIL SF53

CONCRETE REINFORCING BAR DEVELOPMENT AND LAP SPLICE LENGTH SCHEDULE DOWEL SIZE REINFORCING BAR ADHESIVE ANCHORS IN CONCRETE SCHEDULE EMBEDMENT LENGTH (SEE NOTE #2) SIZE (DIA) THREADED ROD EMBEDMENT LENGTH (SEE NOTE #2) 675 E. 5 S. Suite 4 12/1/217 ADHESIVE ANCHORS IN CONCRETE SCHEDULE CONCRETE REINFORCING BAR LAP SPLICE SCHEDULE 13 S GORDON LANE SALT LAKE CITY, UT 8417 SCHEDULES SF61