Prefabricated Light Weight Steel Structures. Systems Guide WALLS, FLOORS, TRUSSES

Similar documents
UL-listed fire ratings 1, 2 and 3 hours Excellent sound ratings STC and IIC Manufactured from recycled steel. 48" to 72" joist spacing, longer spans

STEEL STRUCTURAL SYSTEMS

SECTION COLD-FORMED METAL FRAMING

HAMBRO COMPOSITE FLOOR SYSTEM

SECTION COLD-FORMED METAL FRAMING

PRESENTATION PLAN A MODEL COMPARISON FLOOR CONSTRUCTION

HAMBRO COMPOSITE FLOOR SYSTEM

Structural Technical Report #2 By Robert Whitaker

SECTION COLD-FORMED METAL FRAMING

The Perfect Choice for Mezzanines in Custom Metal Buildings

Building Division Informational Handout

SECTION (formerly 05425) PRE-ENGINEERED, PRE-FABRICATED COLD-FORMED STEEL ROOF & FLOOR TRUSSES

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

UL Design System HW-D-1012 continued

A. Product Data: For each type of cold-formed steel framing product and accessory.

SECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents.

RSIC THE REVOLUTION IN NOISE CONTROL

Retain "Preinstallation Conference" Paragraph below if Work of this Section is extensive or complex enough to justify a conference.

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SECTION PRE-ENGINEERED COLD-FORMED METAL ROOF AND FLOOR TRUSSES

assembly an open space between the roof and ceiling of a building attic balloon frame a joist constructed of steel with bars in the verticle web space

ENGINEERS ENGINEERED SOLUTIONS DEEP-DEK COMPOSITE COMPOSITE LONG SPAN FLOOR DECK.

Technical Report #2. Matthew R Peyton

North Shore at Canton Baltimore, MD Beau Menard Technical Report 1

The Structural Redesign of Boyds Bear Country and its Related Systems. Boyds Bear Country, Pigeon Forge, Tennessee

WOOD I-JOIST AWARENESS GUIDE

BEARING METAL STUD FRAMING

SECTION COLD-FORMED METAL FRAMING

THE STEELFORM GOLD STANDARD. Product Data Sheet. Non-loadbearing Steel Studs (NLB)

DIVISION 5 METALS SECTION COLD-FORMED METAL FRAMING

SECTION WOOD FRAMING. A. Includes But Not Limited To: 1. Furnish and install wood framing and blocking as described in Contract Documents.

DIVISION 5 METALS SECTION METAL DECKING

DIVISION 5 METALS BUSHEY FEIGHT MORIN ARCHITECTS INC. 473 NORTH POTOMAC STREET HAGERSTOWN, MARYLAND FAX:

Table 3. Detailed Comparison of Structural Provisions of IRC 2000 and 1997 NEHRP (Continued)

COFS Mission. AISI Standards Hierarchy. North American Standards for Cold-Formed Steel Framing. Member versus System Design. Specification 10/21/2016

Attachment A. USG Minimum Design and Construction Requirements for Wood Framed Structures

RSIC-1 THE REVOLUTION IN NOISE CONTROL

Crossroads at Westfields Building II

Issue Date: April 2003 Release: I. Product Specifications

Thesis Proposal Structural Redesign / Cost, Schedule and Coordination Analysis / Architectural Impact

LISTING INFORMATION OF International Beams - IB Series Joists SPEC ID: 27316

NATIONAL GYPSUM COMPANY 2-Hour Area Separation Wall System

SECTION (05400) - COLD-FORMED METAL FRAMING

On Cold-Formed Steel Construction. Light Gauge Steel Engineers Association Washington, D.C Toll Free (866)

SUGGESTED COST-EFFECTIVE COLD-FORMED STEEL FIRE AND ACOUSTIC-RATED WALL AND FLOOR/ CEILING ASSEMBLIES FOR MULTI-UNIT STRUCTURES

The Contractor is responsible for quality control, including workmanship and materials furnished by his subcontractors and suppliers.

HACKER SOUND MAT II, to create a quieter living environment while meeting demanding project specifications in multi-family construction.

SECTION NON-STRUCTURAL METAL FRAMING

Project No: Pakenham Branch Library, Pakenham, Ontario Section DECEMBER, 2016 Page 1 of 6

Assemblies Evaluated For 1. Non Axial Load Bearing Wall 2. Transverse Load Capacity 3. Fire Resistance 4. Abuse Resistance

Insulated Cold-Formed Steel Wall Panels: A case study of a contractor-manufacturer

151 First Side. Technical Assignment 2 November 16 th, William J. Buchko. AE 481w Senior Thesis The Pennsylvania State University

Table of Contents.2. Introduction...3 Gravity Loading and Deflections..4. Existing Structural System..8

SJI Updates Expanded Load Tables for Noncomposite Joists / Joist Girders and Development of New Composite Joist Series

Assemblies Evaluated For 1. Non Axial Load Bearing Wall 2. Transverse Load Capacity 3. Fire Resistance 4. Abuse Resistance

OF THREE NEW BUILDINGS BEING CONSTRUCTED TO REPLACE THE EXISTING COMPLEX. THE FLOOR SYSTEM OF GEORGE READ HALL IS A HAMBRO COMPOSITE SYSTEM

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

SECTION NON-STRUCTURAL METAL FRAMING

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings

NATIONAL GYPSUM COMPANY 3-Hour Area Separation Wall System

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

CHAPTER 3 BUILDINGS WITH WOOD FRAMED EXTERIOR WALLS 301 SCOPE

Design No. P725 December 10, Restrained Assembly Rating-1, 1-1/2 or 2 H (See Item 8) Unrestrained Assembly Rating-1, 1-1/2 or 2 H (See Item 8)

George Read Hall. The University of Delaware. Eric Alwine Structural Option Thesis April 2006 Dr. Boothby

AISC Steel & Timber Research for High-Rise Residential Buildings

Copyright. magazine. CFS Load Bearing Construction

Danielle Shetler - Structural option Courtyard by Marriott Lancaster, PA

Home Depot Page 1 of 5 HDPB Humacao, PR 10/19/09

SECTION COLD-FORMED METAL TRUSSES

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

Jonathan R. Torch Technical Report 2 Columbia University. Technical Report 2. Pro-Con Structural Study of Alternate Floor Systems

Specifying Pre-Engineered CFS Floor and Roof Trusses 551f-98

SECTION COMPOSITE METAL DECKING

Statement of Special Inspections Michigan Building Code 2012 (MBC 2012)

TECHNICAL EVALUATION REPORT No. 27/2008/2060

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2011 LARC)

DEEP-DEK COMPOSITE A VERSA-FLOOR SYSTEM

THE FORENSIC MEDICAL CENTER

D500TM. SPC No ( )

Caitlin Ferrell Structural Option Dr. Boothby, AE Faculty Consultant. Erie Convention Center and Sheraton Hotel

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES

SECTION NON--STRUCTURAL METAL FRAMING

Structural Technical Report #2 Pro/Con Study of Alternate Floor Systems

Part 1: Vocabulary Select the best answer and write the corresponding letter in the space provided.

R-Matte Plus-3: Insulation for the Building Envelope

Residential Building Inspections

DIVISION 5 - STRUCTURAL STEEL AND IRON WORK

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

FIRM-FILL SCM-400 can be installed under a FIRM-FILL Gypsum Concrete Floor Underlayment to produce an exceptional vibration isolation floor system.

STEEL STUD, TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION MONTREAL TORONTO CALGARY EDMONTON VANCOUVER THE STRENGTH WITHIN

SECTION COLD-FORMED METAL FRAMING

Matthew Kutzler. Structural Option Spring Buildings C and D Campus Square, Lehigh University Bethlehem, PA

MOUNTAIN STATE BLUE CROSS BLUE SHIELD HEADQUARTERS

Project. San Jose City College Physical Education Building. Prepared For. Prepared By PLACE IMAGE HERE. Ken Bauer, AIA Principal

DIVISION 05 METALS Commissioning of Metals STRUCTURAL METAL FRAMING Structural Steel Framing

SECTION COMPOSITE METAL DECKING

LISTING INFORMATION OF Mitek Design No. MCI/WI SPEC ID: MiTek Canada, Inc. 100 Industrial Road Bradford, ON L3Z 3G7 Canada

SECTION FABRICATED WALL PANEL ASSEMBLIES. A. American Institute of Steel Construction (A.I.S.C.) "Manual of Steel Construction.

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

STATEMENT OF SPECIAL INSPECTION FORM

Transcription:

Prefabricated Light Weight Steel Structures WALLS, FLOORS, TRUSSES www.psiincusa.com 14869 Persistence Drive Woodbridge, Virginia 22191 Phone: 703.550.1466 Fax: 703-550-0486 Systems Guide

Introduction to PSI Company Overview Established in 1979, Panel Systems, Inc. provides the ultimate in Load Bearing, Light Gauge, Panelized Structures. Our In-House Engineering, Fabrication, Delivery, and Installation Departments optimizes cost, efficiency, quality and speed while our ultimate goal is to meet our commitments, do what s best for the job and provide an excellent product. Our Design Teams Light Gauge experience stems from the on-set of the product as a Structural Component. We provide full specialty engineering services for our structures in accordance with the generally accepted rules governing the relationships between the Structural Engineer of Record (SER) and the Specialty Engineer. We are eager to participate in the early design phase to assist in selecting the most economical structural system for the project. Our Walls Typically, PSI includes all (Cold-Formed Metal) Exterior Walls, Interior Load Bearing Walls as well as all Shear Walls and Shear Wall hardware. This normally encompasses all work described under CSI Specification Section 05400. In addition, Structural Steel components such as HSS posts, distribution plates and/or corridor beams are often included in this wall package. PSI panels are factory-fabricated with all GMAW (Mig) welded connections, performed by Welders who have been Qualified in accordance with American Welding Society guidelines for the specific equipment and materials employed. We utilize the state-of-the-art Vertex BD Framer for Light Gauge Steel Program for our design/material procurement, quality control and labeling procedures for each individual panel. Distributed by Argos Systems, Vertex BD is a highly customizable BIM application continuously employed by PSI since 1999. Batts Insulation is factory-installed in exterior wall headers/ boxed assemblies that otherwise would be inaccessible after fabrication. Typically, we exclude wall insulation, interior drywall and all finishes from our bid. Structural (non gauge-metal) Steel is also excluded, except for members which can readily be integrated into the wall panel installation. DESIGN FABRICATION INSTALLATION 2 Panel Systems Inc. www.psiincusa.com 14869 Persistence Drive Woodbridge, Virginia 22191 phone: 703-550-1466 Fax: 703-550-0486

Our Walls Submittals We employ a two-part submittal process. First, an overall engineering submittal is made, including Design Criteria and calculations in an 8 ½ x 11 format, as well as Large Scale Plans, Sections & Details. Second, we prepare all the individual panel elevations and site layout plans which are submitted for record following approval of the Engineering Submittal. LATERAL BRACING DESIGN The SER defines load paths in the structure, in accordance with the AISI Code of Standard Practice, PSI will then design each Shear Wall accordingly. It is assumed that the SER will designate an adequate quantity of Shear Wall locations to allow the use of Light Gauge Straps for the Typical conditions. (PSI is capable of integrating Structural Steel Posts and/or K-Frames at select conditions). BRIDGING-BRACING Horizontal Bracing in the Panels is designed to incorporate the latest AISI requirements including diagonal members to brace the bracing. Our standard Horizontal Bridging technique, (for studs up to 6 ) thick, is to thread 16 ga. Cold Rolled Channel (CRC), through punch-outs and weld the flanges to the studs. BLAST RESISTANCE & PROGRESSIVE COLLAPSE Panelized Light Gauge Framing lends itself well to these new structural requirements for Government Buildings. Enhanced Jambs, Sills, Headers and Slab Connections around openings, help meet blast design requirements. Proper bottom-chord bracing and reinforcing fabric in concrete decks afford the necessary strength to resist upward blast pressures. Continuous HSS distribution plates, rebar, and vertical straps provide the horizontal and vertical ties required to prevent progressive collapse. LEEDS Considerations Cold-Formed Metal Framing is a 100% Recyclable product. Under Leed-NC standards, Total Points Available are 69, with Platinum Certification requiring a minimum of 52 points. Local manufacturing plants and low product weight minimize the carbon footprint of shipping. Fabrication, Delivery & Installation PSI manufactures and installs its own Wall Panels. Field Welders are trained and Qualified per AWS Standards. We utilize a custom designed Quality Control program for every panel. We have the experience and equipment to guarantee on-time Deliveries and Installation in accordance with the strictest Safety & Scheduling standards. Panel Systems Inc. www.psiincusa.com 14869 Persistence Drive Woodbridge, Virginia 22191 phone: 703-550-1466 Fax: 703-550-0486 3

PSI System A 3 Composite Metal Deck System A consists of load-bearing structural stud (braced) walls with a 3 inch deep, 18 gauge metal deck acting as a permanent form to receive a composite concrete slab. Key to the system is the alignment of the vertical studs (@ 24 oc), with the corresponding flutes of the floor deck, thus eliminating the need for load-distribution plates at the top of the stud walls. Given the span characteristics of the 18 gauge metal deck, this system is especially suited for multi-story hotels, dormitories and apartments with stacked bearing walls up to 14 feet apart. ADVANTAGES: Speed (No Shoring 14 Span) Cost (Non Proprietary Pricing) Quantity of Walls Included Floor-to-Floor Height CONSIDERATIONS: Relatively Short Span Open Deck Flutes Bulkheads for HVAC END/BEARING WALL INTERIOR/BEARING WALL SIDE WALL/ ELEVATION 1. 3 Composite Deck 2. Pour-Stop (16 Ga. Typ.) 3. 3 5/8, 4 or 6 Studs @ 24 o.c. 4. Wire mesh reinforcing 5. Line of Drywall 6. Head of Wall Fireproofing as required 7. Load Bearing Framing beyond 8. 5 1/2 to 7 1/2 Slab thickness 9. Rebar FIRE PROTECTION - WALLS: Load-Bearing Wall UL ratings are achieved through the use of layers of 5/8 Firecode sheathing on each side; (one layer = 1 hr/ul #U-425). UL DESIGN # D913 Restrained Concrete Concrete Unit Concrete Assembly Rating Hr (Type) Weight pcf Thkns In. 1 Normal Weight --- 3-1/2 1-1/2 Normal Weight --- 4 2 Normal Weight --- 4-1/2 1 Lightweight 107-113 2-1/2 2 Lightweight 107-113 3-1/4 2 Lightweight 107-120 3-1/2 REF: PCSI FIRE PROTECTION - FLOOR: UL ratings for the Composite Deck system range from 1 hour to 3 hours per UL #D913, and are achieved without protection of the deck by an additional fire-rated ceiling assembly. FIREPROOFING OF FLUTES Firestopping Properties UL Wall Floor Hourly system construction construction rating XHBN.HW- 1 hr. Steel S-0040 gypsum wall fluted deck 1 XHBN.HW- 2 hr. Steel S-0040 gypsum wall fluted deck 2 REF: IBM FIRENAM " 4 Panel Systems Inc. www.psiincusa.com 14869 Persistence Drive Woodbridge, Virginia 22191 phone: 703-550-1466 Fax: 703-550-0486

PSI System B Dovetail Deck System B consists of load-bearing structural stud (braced) walls with a 2 inch deep, Dovetail formed metal deck acting as a permanent form to receive a composite concrete slab. This system affords long spans, typically 16 to 20 feet, with continuous bearing, eliminating the need for load distribution members. The longer spans allow more flexibility in locating loadbearing walls, suitable for almost any type of multi-story residential construction. ADVANTAGES: Long Spans Thin Slabs (less concrete) Standard Wall Fireproofing techniques CONSIDERATIONS: Shoring/Re-shoring requirements. Negative reinforcing steel. 1. 2 DOVETAIL DECK 2. POUR-STOP (16 GA. TYP.) 3. 3 5/8, 4 OR 6 STUDS 4. WIRE MESH REINFORCING 5. REBAR SIDE WALL INTERIOR/BEARING WALL END/BEARING WALL FIRE PROTECTION - FLOOR: UL ratings for the Dovetail composite deck system range from 1 hour to 3 hours per UL #D904, and are achieved without protection of the deck by an additional fire-rated ceiling assembly. FIRE RESISTANCE Restrained Total Depth Total Depth Ratings (Hr.) Normal-weight Concrete Light-weight Concrete 1 Hr. 4 NA 2 Hr. 5.25 4.5 3 Hr. 6.75 5.25 SOUND TRANSMISSION Dovetail Deck Grade I Grade II Grade III 6 Total Depth STC (min) STC (min) STC (min) normal weight concrete 58 55 52 48 LINKS: www.marlynsteel.com www.3m.com/firestop www.metaldek.com Panel Systems Inc. www.psiincusa.com 14869 Persistence Drive Woodbridge, Virginia 22191 phone: 703-550-1466 Fax: 703-550-0486 5

PSI System C Composite Joists System C consists of load-bearing structural stud (braced) walls supporting a composite floor system consisting of bar joists at 48 oc., which receive a steel deck fastened with Shear screws that provide a verifiable composite lock between the joists and a 3 1/2 (standard) concrete slab. The floor system is manufactured by Vulcraft under the trade name Ecospan This system provides great economy at spans of 20 to 35 feet and permits the most floor plan flexibility, without shoring or formwork. ADVANTAGES: Long Spans Fewer Bearing Walls Plenum Space for Mechanicals Joists manufactured locally for LEED calculations. Standard Concrete-over-Deck installation techniques. No down-time for other trades once concrete is poured. CONSIDERATIONS: Distribution Plate may be required Floor-to-Floor height greater than with Composite Deck. LINKS: www.ecospan-usa.com END/BEARING WALL INTERIOR/BEARING WALL SIDE WALL/ELEVATION 1. 1 26 GA. (TYP.) FORM DECK 2. POUR-STOP 3. 3 5/8, 4 OR 6 STUDS (TYP.) 4. WELDED WIRE FABRIC REINF. 5. ECOSPAN STEEL JOIST (2 1/2 MIN. BRG.) 6. SHEARFLEX SHEAR CONNECTOR 7. E-CLOSURE CONCRETE STOP 8. 7/8 FURRING CHANNEL AT 24 o.c. 9. 5/8 GYPSUM BOARD 10. COMPOSITE DECK AT CORRIDOR FIRE PROTECTION - FLOOR: The Ecospan Composite Floor System is listed by Underwriters Laboratories Inc. with multiple Fire Ratings (1 hr. to 3hrs.) for Acoustical and Gypsum ceiling applications. The most common UL code encountered in construction utilizing the Ecospan Composite Floor System is UL Code G561 SOUND TRANSMISSION Flooring Materials/Thickness IIC STC Bare Concrete 26, 30* 57 Carpet 1. 6 PCF PAd (0.4 ) 77 57 2. 100% Pet polyester carpet (0.438 ) Ceramic Tile 1. Loose-laid cork (0.235 ) 51 2. Thinset mortar 54* N/A 3. Glazed ceramic tile (0.3 ) 6 Panel Systems Inc. www.psiincusa.com 14869 Persistence Drive Woodbridge, Virginia 22191 phone: 703-550-1466 Fax: 703-550-0486

PSI System D Cold Formed Joists System D comprises load-bearing structural stud (braced) walls with a light gauge C-Joist Floor framing assembly topped with (either) poured gypsum-cement on metal deck, or reinforced interlocking 3/4 thick Structural Cement Panels fastened directly to the joists. This system eliminates all concrete on the elevated decks, while providing a two hour rated floor assembly (poured gyp) with only one layer of Firecode Gypsum Board. It is suitable for all medium (± 20 ft.) span applications. ADVANTAGES Installation Plenum space Fire Ratings No Concrete Prefab Floors CONSIDERATIONS: Floor-to-Floor Height No Floor Diaphragm 1. 9 1/4 (MIN) 16 GAUGE JOISTS @ 24 o.c. 2. WEB STIFFENER 3. 3 5/8, 4 OR 6 WALL STUDS 4. 9/16 22 GA. GALV. METAL DECK 5. 1 9/16 POURED GYPSUM TOPPING 6. 3 1/2 FR GLASS FIBER INSULATION 7. 1/2 25 GA. RESIL. CHANNELS @ 12 o.c. 8. 5/8 FC GYPSUM BOARD 9. 3/4 STRUCTURAL CEMENT PANEL END/BEARING WALL W/ POURED GYPSUM INTERIOR BEARING WALL W/ POURED GYPSUM SIDE NON-BEARING WALL W/CEMENT PANELS FIRE RESISTANCE Materials HR RATING UL # Poured Gyp 2 G-563 One layer 5/8 FC Gyp Bd. G-574 G-559 Structural Cement Panels One layer 5/8 FC Gyp Bd. 1 G-556 Two layers 5/8 FC Gyp. Bd. 2 G-557 SOUND TRANSMISSION Flooring Materials STC IIC Ceramic Tile & mat 58 46 (Poured Gyp) Carpet & Pad 56 65 (Poured Gyp) Carpet & Pad 52 67 Structural Cement Panel LINKS: www.cemcosteeel.com www.marinoware.com Panel Systems Inc. www.psiincusa.com 14869 Persistence Drive Woodbridge, Virginia 22191 phone: 703-550-1466 Fax: 703-550-0486 7

PSI System E Precast Concrete Plank System E consists of load-bearing structural stud (braced) walls with precast plank of various thicknesses. The plank can have a structural toping applied before the next level of bearing walls is set, or non-structural gypsum concrete leveling can be applied after the structure is complete. Six inch studs are used at the exterior bearing wall while eight inch studs are used at interior walls to provide adequate bearing length for the plank. Stud spacing can be 16 or 24 inches oc depending on the requirements of sheathing. Given the span characteristics of plank bearing walls can be spaced up to 30 feet apart. This system is especially suited for suite type hotels were plenum spaces or highly finished ceilings are not required. 1. POUR STOP 2. GROUT FOR STUD BEARING 3. GROUT PLANK VOIDS 4. DEFLECTION TRACK 5. BEARING STUDS 6. INFILL FRAMING Trusses Panel System Trusses Panel Systems originated cold-formed steel truss design and fabrication in the DC Metropolitan Region. Starting with C-Stud trusses, and now the TrusSteel system utilizing Alpine software. With higher relative stiffness than competitive products, TrusSteel requires less horizontal bracing and is easier and safer to handle, resulting in less damage to the trusses during unloading, hoisting and installation. When necessary, Tube Steel (HSS) Girder trusses may be integrated into the design. ADVANTAGES OVER WOOD NON-COMBUSTIBLE INSECT AND ROT RESISTANT DIMENSIONALLY STABLE. INSPECTION FRIENDLY CURVED CHORD OPTION LEEDS CHARACTERISTICS MR 4.1 (1 POINT) MR 4.2 (1 POINT) MR 3.1 & 3.2 (100% RECYCLABLE) POST CONSUMER RECYCLED CONTENT: 30.9% PRE-CONSUMER RECYCLED CONTENT: 11% FIRE RATED ASSEMBLIES UL File Design Assembly Number Number Description BXUV.P525 P525 TrusSteel Roof Trusses-1, 1-1/2 and 2 Hour Assemblies with a SINGLE layer of gypsum wallboard (steel roof deck). BXUV.P526 P526 TrusSteel Roof Trusses-1 Hour Assembly with a SINGLE layer of gypsum wallboard (plywood as roof deck). 8 Panel Systems Inc. www.psiincusa.com 14869 Persistence Drive Woodbridge, Virginia 22191 phone: 703-550-1466 Fax: 703-550-0486