Review on Agriculture and Rural Development vol. 2. (1) ISSN

Similar documents
The Determination of Toxic Metals in Waters and Wastes by Furnace Atomic Absorption

EPA Primary. (mg/l as CaCO3) (mg/l as CaCO3)

DETERMINATION OF ELEMENTS IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS 10500, & USING THE AGILENT 5100 ICP-OES

The Determination of Trace Elements in Stainless Steel by Forked Platform GFAAS

PINAACLE 500/900 AA AND SUPPLIES CONSUMABLES. Consumables and Supplies Reference Guide

TITLE: SABS PROFICIENCY TESTING SCHEME, RSA

ELEMENTS by ICP 7301 (Aqua Regia Ashing)

CERTIFICATE OF ANALYSIS

ELEMENTS by ICP 7301 (Aqua Regia Ashing)

SUB-Programs - Calibration range Fe Base for "PMI-MASTER Pro" Spark - mode Fe 000

PinAAcle 900 AA Flame AA

Bottom Ash Data Week 45

RECOMMENDED SCOPE OF ACCREDITATION (For Testing Laboratories) * Test Method / Standard against which tests are performed

Bottom Ash Data Week 52

Increased Sample Throughput for ICP-OES Applied to U.S. EPA Method 200.7

Bottom Ash Data Week 47

EPA Methods Update. What s new and what s coming in EPA ICP-MS methods?

Raw Potable Well Water Analysis: Grid Water Analysis: 2009 & 2016

The heavy metals analyses in canned tomato paste

CERTIFICATE OF ANALYSIS

Determination of some trace elements in water samples within kano metropolis

Analysis of Metals in Water, Stream Sediments and Floodplain Soils Collected March 21-23, 2005 from the Bayou Creek System. David J.

ELEMENTS by ICP 7300 (Nitric/Perchloric Acid Ashing)

Standard Solutions (Traceable to NIST)

Standard Solutions (Traceable to NIST)

Amplifying ICPMS Productivity Using Discrete Sampling Technology

Environment Agency. The determination of metals in solid environmental samples (2006) Methods for the Examination of Waters and Associated Materials

SUB-Programs - Calibration range Fe Base for "FOUNDRY-MASTER UV"

Fields of Application / Industry:

US EPA Method using the Thermo Scientific icap 7600 ICP-OES Duo

Dr. Jianfeng Cui, Thermo Fisher Scientific, Bremen, Germany APPLICATION NOTE AN43384

Schedule of Accreditation

The Determination of Trace Elements in Waters using the US EPA Method and the Thermo Scientific icap 6500 ICP-OES (Duo)

High-Purity Acids & Reagents

Analysis of an OTC Multivitamin Tablet Using X-ray Fluorescence Spectroscopy and Atomic Absorption Spectroscopy

METAL PARAMETERS METAL PARAMETER METHOD CODE TECHNOLOGY. EPA SM 18 th, 19 th 3113 B SM 18 th, 19 th 3111 D SW B EPA 200.

The objective of this document is to specify the chemicals characteristics and properties of the material Steel AISI Carbon Steel.

Atomic Absorption Spectrometry. The Analyzer 4 You novaa 800

EDX 600. Atomic Absorption Spectrometry

Appendix U. Mapping of Water Quality Concentration Contours across the Province

National Food Safety Standard

Improved Antimony Recoveries in Soil Matrices by 3050B/6010B. DataChem Laboratories, Inc. Robert P. Di Rienzo Jeffery S. Ward John T.

Background Statement for SEMI Draft Document 4795 (Yellow Ballot) NEW STANDARD: SPECIFICATIONS FOR NITRIC ACID, USED IN PHOTOVOLTAIC APPLICATIONS

Photochemical studies of Eichhornia crassipes (Water Hyacinth)

Inorganic Trace Analysis. Pure confidence

CERTIFICATE OF ANALYSIS REVISED REPORT

CERTIFICATE OF ANALYSIS

ISO INTERNATIONAL STANDARD. Iron ores Determination of various elements by X-ray fluorescence spectrometry Part 1: Comprehensive procedure

CERTIFICATE OF ANALYSIS

SEMI C SPECIFICATIONS AND GUIDELINES FOR HYDROGEN PEROXIDE

CERTIFICATE OF ANALYSIS 1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION

CERTIFICATE OF ANALYSIS 1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION

Background The document will be revised for its five year review and updated per the committee agreed upon changes.

CERTIFICATE OF ANALYSIS REVISED REPORT

US EPA Method using the Thermo Scientific icap 7600 ICP-OES Duo

Research Article. Assessment of heavy metal contamination in Chemberambakkam lake water, Chennai, Tamil Nadu, India

VHG Labs. Standards and Supplies for Spectrochemical Analysis QUALITY. TRACEABILITY. DEPENDABILITY. WORLDWIDE

DRINKING WATER ANALYSIS SUMMARY

ph, hardness and elemental profile if rain water (zinc roofing sheet vs open air collection)

Appendix C: Water Quality Data

CERTIFICATE OF ANALYSIS

Background Statement for SEMI Draft Document 4546A REVISION OF SEMI C , with title change to SPECIFICATIONS FOR HYDROGEN PEROXIDE

Schedule of Accreditation

CERTIFIED REFERENCE MATERIALS (CRM)

Trace elements determination AAS

Soil Sampling, Preparation and Analysis

Composition Analysis of Animal Feed by HR ICP-OES

SEMI C SPECIFICATIONS AND GUIDELINES FOR AMMONIUM HYDROXIDE

Passive Water Distillation: Water QualityAnalysis

Annex 7.1 National Ambient Air Quality Standards for Nepal, 2003

Analysis of Cast Iron Using Shimadzu PDA-7000

Method (0.1 to 8.0 mg/l Cu) TNTplus 860

ARC XL Series. Broadband g-line & i-line Anti-Reflective Coatings

Why Hach Reagents? Alphabetical Listing of Reagents

High-Purity Acids & Reagents

CERTIFICATE OF ANALYSIS

Fly Ash Testing Results PEI Energy Systems Waste Combustion Ash

Flame Atomic Absorption Spectrometer (FAAS) Brand : PERKINALMER Model : PinAAcle 900T Custodian : PRADUP MESAWAT SOOKRUTHAI WONGSUBIN

EU Water Analysis Using the Thermo Scientific icap 7400 ICP-OES Duo

Trace Metals in Waters by GFAAS, in Accordance with U.S. EPA and Health Canada Requirements

Radial, Axial or Dual View ICP: Which Do You Choose? Manny Almeida Teledyne Leeman Labs, Inc. Hudson, NH

Analysis of Copper and Copper Base Alloys, Using Shimadzu PDA-7000

EPA Methods Update 2. What s new and what s coming in EPA ICP-MS methods? 200.8

Rubber and plastics gloves for food services Limits for extractable substances

INTERNATIONAL STANDARD

Multi-Element Analysis of Trace Metals in Animal Feed using ICP-OES

Safety Data Sheets (SDSs) Soon To be Avalable for Purchase from AFS

Madhya Pradesh Waste Management Project Laboratory, Plot No. 104, Industrial Area No. II, Pithampur, Dhar, Madhya Pradesh

EU water analysis using the Thermo Scientific icap 7400 ICP-OES Duo

High Purity Acids Trace Elemental Analysis. Detect as low as 1 to 100 ppt

SILLIKER, Inc. Southern California Laboratory 6360 Gateway Drive, Cypress, CA Tel. 209/ Fax. 714/

ADDITIONAL SCIENCE/CHEMISTRY. A.M. TUESDAY, 14 January hour

ADDITIONAL SCIENCE/CHEMISTRY. A.M. TUESDAY, 14 January hour

This method is applicable to the following parameters: Nitric Hydrochloric acid digestion, Instrumental analysis.

Concentration of Metals (Cd, Hg, Ag; mean +SD) in sediment samples collected from Pit Specific Sediment Chemistry Monitoring for CMP 1 in May 2014.

Analysis of Trace Metals in Tobacco and Tobacco Ash using Atomic Emission Spectroscopy

ICP-AES Determination of 15 Kind of impurity elements in the Vanadium-aluminum alloy

ABSTRACT: Clean sampling and analysis procedures were used to quantify more than 70 inorganic chemical constituents (including 36 priority

Appendix V6-2A Analytical Results of the Umwelt Westbay Groundwater Sampling Program

Assessment of Water Quality of Three Different Aquatic Environments Over Three Seasons

Transcription:

Review on Agriculture and Rural Development 2013. vol. 2. (1) ISSN 2063-4803 245 QUANTITATIVE DETERMINATION BY ATOMIC ABSORPTION SPECTROMETRY FOR MICRO ELEMENTS OF MINERAL WATERS FROM ROMANIA GABRIEL HEGHEDŰŞ-MÎNDRU 1, RAMONA CRISTINA HEGHEDŰŞ-MÎNDRU 1, PETRU NEGREA 2, DUCU SANDU ŞTEF 1, RADU LIVIU ŞUMĂLAN 1, LUCIAN MIRCEA RUSNAC 2 1 University of Agricultural Sciences and Veterinary Medicine of Banat of Timisoara Faculty of Food Products Technology Timisoara 300645 Calea Aradului No.119 Romania 2 Polytechnic University of Timisoara Faculty of Industrial Chemistry and Environmental Engineering Timisoara 300006 P-ta Victoriei No. 2 Romania. gabone2003@yahoo.com ABSTRACT The aim of this paper is to present the results of studies for some microelements from mineral water. Mineral water was collected from three different regions of Romania (West Region, Centre Region and North Region). The microelements: lead (Pb), nickel (Ni), manganium (Mn), iron (Fe), cooper (Cu), chromium (Cr), and cadmium (Cd) were analyzed by atomic adsorption spectrometry determination, using the graphite tubular electrothermic owen method VARIAN GTA 110. As a conclusion, the lead (Pb) maximum value recorded for the west region waters was in sample A1 (18.6 µg/l), the nickel (Ni) exhibits maximum value in center region, in sample C2 (54.15 µg/l), the manganium (Mn) reaches the maximum in the west region in sample A1 (360 µg/l), the iron (Fe) exhibits maximum value in sample B3 (6.25 µg/l) from north region, and for the cadmium (Cd), the maximum value was reached in sample A1 (8.18 µg/l) from the west region. When comparing the allowable limits for heavy metals, (ORDER NO. 975 OF 16 DECEMBER 1998 ON THE APPROVAL RULES OF THE SANITARY HYGIENIC FOOD) were not observed exceedances of microelements concentrations studied. Keywords: mineral water, atomic adsorption spectrometry (AAS), micro elements, tubular owen, geographical regions INTRODUCTION For the determination of trace metals in natural and mineral waters different spectrochemical methods are used. However, flame atomic absorption spectrometry (FAAS) is one of the most extensively used techniques for determining various elements with significant precision and accuracy. This analytical technique is remarkable for its selectivity, speed and fairly low operational cost.9 However, in some cases there are many difficulties in determining traces of heavy metals in environmental samples due to insufficient sensitivity or matrix interferences. (TAUTKUS, 2004) The water contains some amount of mineral constituents which iron (Fe), magnesium (Mg), lithium (Li), zinc (Zn), copper (Cu), chromium (Cr), nickel (Ni), cobalt (Co), vanadium (V), arsenic (As), molybdenum (Mo), selenium (Se), lead (Pb) and so many others. The quality required of water varies with the use to which the water is to be put. Some people prefer bottled water to sachet water as they believe that it is hygienically prepared. Some people drink only bore hole water or well water as it is the only available source especially in rural areas where bottled and sachet are not produced or too expensive to buy. (OGBONNA, 2011; *** ISO 9174, 1990; *** ISO 8288, 1986) Atomic spectroscopy is one of the most widely used methods for quantitative elemental analysis. There are a number of situations where elemental composition is important e.g., how much iron in an ore sample, how much lead in your drinking water, calcium in intracellular fluids. In a sense, it s the simplest type of analysis, since there are only about 120 possible analytes. But to do the analysis, the sample has to be completely destroyed

Review on Agriculture and Rural Development 2013. vol. 2. (1) ISSN 2063-4803 246 (chemically and physically) and reduced to individual gas phase atoms (or related species, like ions) in well defined states that you can do spectroscopy on. Obviously this requires a very highly energetic environment and a lot of modification of the sample, both of which lead to a number of complications. These problems can be addressed if their presence is anticipated and the physical mechanism is understood. In addition to giving you a little experience with AAS (Atomic Absorption Spectrophotometry) and AES (Atomic Emission Spectrophotometry) for quantitative determination of a few elements. (HTTP://WEB.PDX.EDU/~ATKINSDB/TEACH/427/EXPT-ATOMICSPEC.PDF) The Flame Atomic Absorption Spectrometry (F-AAS) and Flame Atomic Emission Spectrometry (F-AES) are the most often used instrumental techniques for the determination of many elements in different types of natural waters, including rain waters, fresh waters, mineral waters, brines and wastewaters. (JOŃCA, 2004; *** DRINKING-WATER QUALITY, 2004) MATERIAL AND METHOD Spectrophotometer VARIAN Spectr AA 110; Electro thermal graphite tubular oven VARIAN GTA 110 type; Flame type: air/acetylene; Protection gas: argon; air flow: 3,50L/min; acetylene flow: 1,50L/min. The water samples were taken from three different regions of Romania, as follows: West Region: Mineral water source 1 (A1); Mineral water source 2 (B1); Mineral water source 3 (C1); Centre Region: Mineral water source 1 (A2); Mineral water source 2 (B2); Mineral water source 3 (C2). North Region: Mineral water source 1 (A3); Mineral water source 2 (B3); Mineral water source 3 (C3). The lead (Pb), nickel (Ni), manganium (Mn), iron (Fe), cooper (Cu), chromium (Cr), and cadmium (Cd) elements determination was performed with the graphite tubular electrothermal oven because this method exhibits a greater sensitivity towards ppb concentration (µg/l) The work parameters obtained on apparatus calibration in order to determinate lead (Pb), nickel (Ni), manganium (Mn), iron (Fe), cooper (Cu), chromium (Cr), and cadmium (Cd) elements, are shown in table 1 and the afferent calibration curves are shown in figure 1. Table 1. Work parameters at Pb, Ni, Mn, Fe, Cu, Cr, Cd by atomic adsorption spectrometry determination, using the graphite tubular electrothermic owen method VARIAN GTA 110 Experimental conditions Analyzed element Pb Ni Mn Fe Cu Cr Cd Sample taking Automatic Calibration way Concentration Measure units µg/l Method used Graphite tubular electrothermic owen Protection gas Argon Measurement method Pick height Standard precision [%] 1 5 1 1 5 1 1 Samples precision [%] 1 5 1 1 5 1 1 Expansion factor 1 1 1 1 1 1 1 Mediating degree, points 5 5 5 5 5 5 5 Wavelength, [nm] 283.3 232.0 403.1 372.0 327.4 429.0 228.8 Slot width, [nm] 0.5 0.2 0.2 0.2 0.5 0.5 0.5 Voltage on lamp, [V] 38 32 40 45 39 23 50 Electricity on lamp [ma] 10 4 5 5 4 7 4 Standard 1, [µg/l] 10 10 50 50 20 10 2 Standard 2, [µg /L] 20 20 75 75 40 20 4 Standard 3, [µg /L] 30 30 100 100 60 20 6 Standard 4, [µg /L] 40 40 - - 75 40 8 Standard 5, [µg /L] 50 50 - - - 50 10 Measurement time, [s] 68 68 68 68 68 68 68 Working temperature ºC 85-2100 85-2400 85-2400 85-2300 85-2300 85-2600 85-1800 The injected sample volume [µl] 20 20 20 20 20 20 20

Review on Agriculture and Rural Development 2013. vol. 2. (1) ISSN 2063-4803 247 Calibration curves for Pb Calibration curves for Ni Calibration curves for Mn Calibration curves for Fe Calibration curves for Cu Calibration curves for Cr Calibration curves for Cd Figure 1. Calibration curves obtained for the analyzed elements Pb, Ni, Mn, Fe, Cu, Cr, Cd elements determination by graphite tubular electrothermic own, has led to the following results, shown in table 2. Table 2. Atomic adsorption determination of Pb, Ni, Mn, Fe, Cu, Cr, Cd elements Mineral water samples West Region Centre region North Region A1 B1 C1 A2 B2 C2 A3 B3 C3 Chemical element µg/l Pb 18.60 5.40 1.70 6.90 1.45 4.27 2.43 9.11 5.51 Ni 31.74 12.66 4.89 21.04 9.81 54.15 12.61 14.16 4.78 Mn 360 327 0.81 144 241 260 352 334 4.395 Fe 4.84 6.00 1.67 5.07 2.36 1.96 4.40 6.25 0.34 Cu - - - - - - - - - Cr 4.10 - - 1.35-1.55-6.13 - Cd 8.18 6.05 3.07 - - - 1.91 1.13 - The atomic absorption analysis, using the graphite tubular electrothermic owen, allowed the quantitative determination of (Pb, Ni, Mn, Fe, Cu, Cr, Cd) elements, from the three region of Romania, as follows: West region (A1, B1, C1) samples - Pb, Ni, Mn, Fe, Cu, Cr, Cd Regarding the west region, head exhibits the maximum in sample A1 (18.60 µg/l), for sample B1 the value recorded was 5.40 µg/l, and the minimum of 1.70 µg/l obtained was in sample C1. Nickel reaches the maximum in sample A1 (31.74 µg/l), the minimum for nickel

Review on Agriculture and Rural Development 2013. vol. 2. (1) ISSN 2063-4803 248 being recorded in sample C1 (4.89 µg/l), and for sample B1 there was obtained a value of 12,66 µg/l nickel. For manganium, the maximum reached was in sample A1 (360 µg/l), sample B1 reaches 327 µg/l value, and the minimum recorded for this element was 0.81 µg/l in sample C1. The iron element, for the west region, exhibits the maximum value in sample B1 (6.00 mg/l), the minimum reached for iron being 1.67 µg/l in sample C1, while for sample a1 a value of 4.84 µg/l iron was obtained. The performed analysis for this region in the case of cooper, have led to negative results. The chromium element exhibits a single value in sample A1 (4.10 µg/l), for sample B1 and C1, respectively, the chromium is absent. Cadmium exhibits the maximum value in sample A1 (8.18 µg/l), sample b1 recorded a value of 6.05 mg/l, and the minimum obtained value for this element was recorded in sample C1 (3.07 µg/l). Center region (A2, B2, C2) samples - Pb, Ni, Mn, Fe, Cu, Cr, Cd The lead reaches the maximum of this region, in sample A2 (6.90 µg/l), sample C2 exhibits a 4.27 µg/l value, the minimum of lead being recorded in sample B2 (1.45 µg/l). For nickel, the maximum value was recorded in sample C2 (54.15 µg/l), sample A2 exhibits a value of 21.04 µg/l, the minimum recorded being of 9.81 µg/l in sample B2. The manganium exhibits the maximum value in sample C2 (260 µg/l), the minimum value being recorded in sample A2 (144 µg/l), and for sample B2 a value of 241 µg/l was obtained. The iron, in this region, reaches the maximum in sample A2 (5.07 µg/l), sample B2 exhibits a 2.36 µg/l value, and the minimum reached is recorded in sample C2 (1.96 µg/l). The analysis performed for this region, in the case of cooper have led to negative results. The chromium records the maximum value vas of 1.35 µg/l, and for sample B2 the recorded results were negative. For cadmium, no positive results were recorded for this region. North region (A3, B3, C3) samples - Pb, Ni, Mn, Fe, Cu, Cr, Cd The lead reaches the maximum value for this region in sample B3 (9.11 µg/l), the minimum value for this element being recorded in sample A3 (2.43 µg/l), while sample C3 exhibits a value of 5.51 µg/l. The maximum value recorded for nickel was in sample B3 (14.16 µg/l), sample A3 exhibits a value of 12.61 µg/l, the minimum being recorded for nickel in sample C3 (4.78 µg/l). manganium reaches the maximum value for the North region, in sample A3 (352 µg/l), the minimum value being obtained in sample C3 (4.395 µg/l) and for sample B3 a value of 334 µg/l. In the case of iron, the maximum value was recorded in sample B3 (6.25 µg/l), sample A3 exhibits a 4.40 µg/l value, and the minimum recorded for this elements was in sample C3 (0.34 µg/l). The analysis performed in this region for cooper, have led to negative results. The chromium exhibits a single value in this region, in sample B3 (6.13 µg/l), the other analyses samples have exhibited negative results. For cadmium, the maximum value was recorded in sample A3 (1.91 µg/l), the minimum being 1.13 µg/l in sample B3, while sample C3 does not exhibit positive results in cadmium analysis. The lead reaches the maximum in waters from west region, in sample A1 (18.60 µg/l), sample A2 (6.90 µg/l) exhibits the maximum for centre region, and sample B3 exhibits the maximum value 9.11 µg/l for north region. (Figure 2) For nickel, the maximum recorded value in waters from west region was 31.74 µg/l in sample A1, the centre region exhibits the maximum in sample C2 (54.15 µg/l), and sample B3 exhibits the maximum 14.16 µg/l in north region. (Figure 3) Manganium reaches the maximum for waters from west region in sample A1 (360 µg/l), the centre region maximum for this element in sample C2 (260 µg/l), and the maximum value for north region is for sample A3 (352 µg/l). (Figure 4) For iron the maximum for waters from west region in sample B1 (6 µg/l), the centre region maximum for this element in sample A2 (5.07 µg/l), and the maximum value for north region is for sample B3 (6.25 µg/l) (Figure 5).

Review on Agriculture and Rural Development 2013. vol. 2. (1) ISSN 2063-4803 249 Cooper was not identified in the analyzed mineral waters. The chromium was identified in the west region waters and in north region in one sample A1 (4.1 µg/l) and B3 (6.13 µg/l) respectively, in centre region the chromium exhibits maximum in sample C2 (1.55 µg/l). (Figure 6) Cadmium exhibited the maximum for waters in west region, in the case of sample A1 (8.18 µg/l), in the center region was not identified, and for the north region the maximum value was 1.91µg/L in sample A3. (Figure 7) As a conclusion, the leads maximum value recorded for the west region waters was in sample A1 (18.6 µg/l), the nickel exhibits maximum value in centre region, in sample C2 (54.15 µg/l), the manganium reaches the maximum in the west region in sample A1 (360 µg/l), the iron exhibits maximum value in sample B3 (6.25 µg/l) from north region, and for the cadmium, the maximum value was reached in sample A1 (8.18 µg/l) from the west region. (Figure 8) Figure 2. Pb concentration in the mineral Figure 3. Ni concentration in the mineral Figure 4. Mn concentration in the mineral Figure 5. Fe concentration in the mineral

Review on Agriculture and Rural Development 2013. vol. 2. (1) ISSN 2063-4803 250 Figure 6. Cr concentration in the mineral Figure 7. Cd concentration in the mineral water samples, taken into discussion Figure 8. Pb, Ni, Mn, Fe, Cu, Cr, Cd concentration in the mineral water samples from three regions of Romania ACKNOWLEDGEMENTS This work was carried out during the project Post-doctoral School of Agriculture and Veterinary Medicine Posdru/89/1.5/S/62371 co-financed by the European Social Fund the Sectorial Operational Programme for the Human Resources Development 2007-2013. REFERENCES JOŃCA, Z. LEWANDOWSKI, W. (2004): Verification of Measurement Capabilities of Flame Atomic Spectrometry for the Determination of Sodium, Potassium, Magnesium, and Calcium in Natural Fresh Water Part I. Comparison of Recommended Methods, Polish Journal of Environmental Studies, Vol. 13, No. 3, pp. 275-280. OGBONNA, O. JIMOH, W.L. AWAGU, E.F. BAMISHAIYE, E.I. (2011): Determination of some trace elements in water samples within kano metropolis, Pelagia Research Library, Advances in Applied Science Research, 2 (2). pp. 62-68, www.pelagiaresearchlibrary.com TAUTKUS, S. STEPONENIENE, L. KAZLAUSKAS, R. (2004): Determination of iron in natural and mineral waters by flame atomic absorption spectrometry, Journal of the Serbian Chemical Society 69(5) pp. 393 402.

Review on Agriculture and Rural Development 2013. vol. 2. (1) ISSN 2063-4803 251 *** DRINKING-WATER QUALITY (2004): Guidelines for Third Edition Volume 1, World Health Organization, Geneva, pp. 515. *** ORDER NO. 975 OF 16 DECEMBER 1998 ON THE APPROVAL RULES OF THE SANITARY HYGIENIC FOOD *** ISO 9174 (1990): Water quality - Determination of chromium - Atomic absorption spectrometric method (In Romanian). *** ISO 8288 (1986): Water quality - Determination of cobalt, nickel, copper, zinc, cadmium and lead - Method using flame atomic absorption spectrometry (In Romanian). HTTP://WEB.PDX.EDU/~ATKINSDB/TEACH/427/EXPT-ATOMICSPEC.PDF