January 28, Innovative Technology: Development of the Self-cleaning. Wet-well. Robert Domkowski Engineering Consultant

Similar documents
Innovative Technology: Development and implementation of a self-cleaning wet-well

Contents Page. Foreword... xi. 9.8 Pump intake design Introduction Purpose Scope...1

Presentation Outline. Historical Perspective on Wet Wells. Historical Perspective on Wet Well Design. The Trench-Type Self-Cleaning Wet Well

When confronted with increasing peaking. Managing the deluge

TOP Optimal pump sumps for wastewater Zbigniew Czarnota

A SIMPLE SOLUTION TO BIG SNAIL PROBLEMS - A CASE STUDY AT VSFCD S RYDER STREET WASTEWATER TREATMENT PLANT

INITIAL TREATMENT By Kenny Oyler. Headworks:

ENGINEERED SOLUTIONS. CDS Inspection and Maintenance Guide New Jersey

Wastewater treatment for single houses. D. O Dowd

Terre Kleen Maintenance Procedures

SEPTIC TANK CONSTRUCTION GUIDELINES

FAYOUM CITY SEWAGE TREATMENT PLANT, DEVELOPMENT STAGES, CASE STUDY

CHAPTER 5 SEWAGE PUMPS AND LIFT STATIONS

Energy Efficiency in Pump Stations Part 2 Wastewater

Advanced Grit Removal Technology

Pit Systems & Accessories. Water Treatment Systems. Mi-T-M Water Treatment Systems provide a better tomorrow by protecting our environment today.

TECHNICAL SPECIFICATION FOR CURED-IN-PLACE MANHOLE REHABILITATION LINER SYSTEM

Liquid Stream Fundamentals: Grit Removal

City of Muskogee Pollution Control Department POLICY STATEMENT FOR GREASE AND OIL CONTROL

SECTION 820 PUMP STATION DEMOLITION AND SITE RESTORATION

Akiki Engineering Est.

Tank Functions. Solids removal by settling & floatation. Anaerobic digestion Storage of solids % solids removal

June 19, 2013 Annual OWEA Conference Steven Reese, P.E.

SECTION 10.3 PREROSTAL FLOW MATCHING & SUMP CLEANING SYSTEM PREROSTAL VERSUS ARCHIMEDEAN SCREW PUMPS SECTION 10 [10.3]

HUBER Sewerage Program

14. SCREENS. in the Figure 8.1. BARS TROUGH

A Homeowner s Guide to. Septic Systems

Bioreactor Landfill Design

The EHS SMART-Treat On Site Wastewater Treatment System Site Location & Installation Manual

Lagoon Pumping and Irrigating Equipment

Rugged, reliable and efficient sump pumps... your assurance of a dry basement!

Types of Hydropower Facilities

COLLECTION AND DISTRIBUTION OF WATER

Water2014 is essential to life

بسم هللا الرحمن الرحيم

A Homeowner s Guide to Septic Systems

Misan University - College of Engineering Civil Engineering Department

Maintenance Procedures

Experior as an Energy Savings Solution for Wastewater Lift Stations. Lisa Riles NA Marketing and Business Development Manager Xylem

MWMC Eugene-Springfield WPCF Facility Plan Secondary Clarifier Enhancement Alternatives

SECTION SLUDGE HOLDING TANK DEWATERING

Module 9 : Sewage And Storm water Pumping Stations. Lecture 11 : Sewage And Storm water Pumping Stations

Aqua-Swirl Stormwater Treatment System

SECTION PRECAST CONCRETE MANHOLES

Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form - Not for Voluntary Assessments

Aqua-Swirl Stormwater Treatment System

TYPICAL INSTALLATION INSTRUCTIONS

Supplemental Pumps Pay Off During Low River Conditions

HAZOP Checklist for Sewage Treatment Plant

FAIRBANKS NIJHUIS SUBMERSIBLE SOLIDS HANDLING PUMPS.

UPGRADING GAZA WASTEWATER TREATMENT PLANT. Gaza City is populated with 550,000 inhabitants and it forms 45% of the Gaza strip population.

Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form - Not for Voluntary Assessments

STORM DRAINAGE CHAPTER 11

Installation Guidelines for Flygt Pumps Pump Anchoring Recommendations

Sanitary Sewer Extensions, Lift Stations, and Force Mains Engineering Report Form. I. General Information. 1. Name of Facility:

Well and Septic Standards. Tom McCarty Penn State Extension May 13, 2010

FAIRBANKS NIJHUIS SUBMERSIBLE SOLIDS HANDLING PUMPS.

Table of Contents Introduction... 3

WASTE WATER TREATMENT SYSTEM

Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form - Not for Voluntary Assessments

L3. Design Criteria of wastewater collection system

Commonwealth of Massachusetts Title 5 Official Inspection Form. Subsurface Sewage Disposal System Form - Not for Voluntary Assessments

Start and Finish Dates: You will have 90 days from this date in order to complete this course

Wastewater Treatment Works... The Basics

Self-Cleaning Trench-Type Wet Well Design

SECTION TRENCHING

INSTALLATION OF A STEP-SCREEN & VORTEX GRIT REMOVAL SYSTEM AT THE GRIFFITH SEWAGE TREATMENT PLANT. Peter Shanahan. Griffith City Council

THIS IS A COURTESY COPY OF THIS RULE. ALL OF THE DEPARTMENT S RULES ARE COMPILED IN TITLE 7 OF THE NEW JERSEY ADMINISTRATIVE CODE.

Domestic Waste Water (Sewage): Collection, Treatment & Disposal

Figure 1. Report of Inspection Process Flowchart.

Optimizing Wastewater Upgrade Projects with Improved Hydraulics

AQUATEK rainwater harvesting systems can reduce mains water consumption in the average domestic dwelling by up to 50%."

Flygt N-Pumps 3085, 3102 & For reliable and efficient wastewater handling

BIOROCK also provide systems for domestic wastewater treatment for communities ranging from 20 to150 persons.

STANDARD SPECIFICATION FOR OIL GRIT SEPARATOR (OGS) STORMWATER QUALITY TREAMENT DEVICE

Jet Aeration Systems

LAKESIDE Water Purification Since Bulletin #1218 Revised June Spiravac Clarifier. Peripheral Feed Center Takeoff Suction Sludge Removal

HUBER Sewerage Program

City of Malibu Stuart Ranch Road Malibu, California Phone (310) Fax (310)

INSTALLATION INSTRUCTIONS. MODEL Version W SUBMERSIBLE SUMP PUMP

MUNCIE WASTEWATER TREATMENT PLANT 5150 KILGORE AVE. MUNCIE, IN 47304

City of Grosse Pointe Park Sanitary Sewer System Inflow and Infiltration Investigation Smoke Testing

1 Construction The sewage treatment plant (STP) is to be an Icon-Septech Pty Ltd Turbojet 4000 as described below and as shown on the drawings.

Model T Professional Series 1/2HP 2 YEAR WARRANTY SUBMERSIBLE SUMP PUMP

1 Construction The sewage treatment plant (STP) is to be an Icon-Septech Pty Ltd Turbojet 5000 as described below and as shown on the drawings.

TECHNICAL SPECIFICATION

STORM DRAINAGE CHAPTER 11

Section 401. PIPE CULVERTS

t y p e V S A S E W A G E P U M P

Thornton Sewer Plant Operations Manual -DRAFT-

/ /

Flygt Advanced Low Pressure Sewer System Package

Capacity Analysis for the Hartsburg Wastewater Lagoon

DRAFT PTP-06. Activity: Water Quality Units

Appendix D Index. SWM/BMP Facility Site Photographs. Subshed 440 Facility Photo #

1 Construction The sewage treatment plant (STP) is to be an Icon-Septech Pty Ltd Turbojet 2000 as described below and as shown on the drawings.

Modal Analysis as a Tool to Resolve Pump Vibration Issues

200 Series In-Slab Pool Fittings

EFFECTIVE AND EASILY MAINTAINED TREATMENT SOLUTIONS

SECTION SANITARY WASTE INTERCEPTORS

Transcription:

January 28, 2015 Innovative Technology: Development of the Self-cleaning Wet-well Robert Domkowski Engineering Consultant

Overview Over the years, little investigative work has been attempted in advancing modern wet well designs The result: end-users have continued to endure poorly operating sumps

Project introduction: Summary of an investigation into the optimum shape and performance of circular sumps with submersible solids-handling pumps in sewage applications Providing an in-depth look at the ability of circular sumps to deal with solids normally found in domestic sewage

Project background: Simple circular, flat-bottomed wet wells have been employed for decades End-users have suffered with pump sumps that became fouled with trash, sludge and settled solids Owners routinely spend operating funds cleaning and maintaining wastewater pumps and wet wells

Project objective: Evaluate how effectively solids can be removed from wet-wells by pumps in two different sumps (a) A standard 5-4 dia. flat-bottom circular wet-well (b) A wet-well having the geometry of the proto- typical IT station (c) The effectiveness of a sump mixing device was also tested in both sump examples.

Driving force behind laboratory investigation: Fouled wet wells Sludge bank deposits Foul odor generation Choking of pumps Need for frequent station cleaning

A view of the basic conventional pump sump

Initial investigation: Solids-handling pumps w/ 4 dia. suction inlet Test clearance dimensions between two pumps while in simultaneous operation - Pump clearances of 36-in down to 0-in were examined - No noticeable change in pump performance was measured Clearance varied

Initial investigation: Solids-handling pumps w/ 4 dia. suction inlet Test various pump inlet-to-floor clearance dimensions -Pump performance was measured as floor clearance was varied from 16-in through 1-in. -Floor clearance ratio (Clearance / Inlet dia.) of >/= 0.4 delivered unaffected performance (>1.6 clearance) -For solids-handling pumps a 3 to 4 clearance is used Clearance varied

The area of influence: 2-3 x Pump inlet diameter Typical pump station flat bottom Area of pump suction influence Pump inlets

Modification 1: Place one sloping wall, downstream of pumps Result: Power consumption increased 5% due to pre-swirl rotation

Modification 2: Two sloping walls, one downstream, one up stream from pump Result: Power consumption increased 10% due to pre-swirl rotation

Modification 3: Four vertical walls surround pump Result: Slight decrease in power consumption, higher n hyd %; no rotation around pump

Cantilever type Submersible type

Cantilever type Submersible type

Adapting circular sumps to sewage solids Various densities of solids enter wet wells: Floating solids form surface blankets Sinking solids accumulate on sump floor in stagnant zones Solids can be removed from station if they come close enough to the influence of the pump intake The influence of the pump intake stretches only 2-3 inlet diameters for both floating and sinking solids

Adapting circular sumps to sewage solids Development test #1 Floating items Two wet well types are chosen for comparison - Conventional wet-well with 5-4 diameter - TOP 100 wet-well Place 8 # of 2 types of plastic beads in each wet-well - Measure the mass of floating beads pumped out of a 5-4 dia. sump and a TOP 100 sump - Fill each sump 12 x with 200 gal and empty the sump - Use pump-off level at the bottom of the volute Compare results from the two sumps

Adapting circular sumps to sewage solids 8 7 90% Dry mass (lbs.) 6 5 4 3 2 1 75% 23% 25% PS PE 0 TOP 100 Conventional 5'-4"

Adapting circular sumps to sewage solids Developmental test #2 Sanitary items Two wet-well situations are chosen for comparison -TOP 100 wet-well -TOP 100 wet-well along with sump mixing device 200 gallons of water were introduced each cycle - Sump was filled / emptied in 12 cycles - Compare results of the tests

Adapting circular sumps to sewage solids TOP sump, pumps w/o sump mixing device 10 9 8 Items 7 6 5 4 3 2 1 Tampons Sm rags Lg rags Condoms 0 Initial 6 Cycles 12 Cycles

Adapting circular sumps to sewage solids TOP sump, pumps with sump mixing device 10 9 8 Items 7 6 5 4 3 2 1 Tampons Sm rags Lg rags Condoms 0 Initial 6 Cycles 12 Cycles

Adapting circular sumps to sewage solids Developmental test #3 Sand / grit settling solids Two wet wells are chosen and inter-connected - Conventional 5-4 diameter wet well - TOP 100 wet well 110 pounds of sand and floating plastics are placed into each wet-well (220 total pounds) - The system is filled with 200 gallons of water - Each wet well is emptied back into the other a total of 10 times each

Adapting circular sumps to sewage solids 5-4 dia. wet-well TOP 100 wet-well 10 x

Adapting circular sumps to sewage solids Conventional wet-well 207 # of the sand remained in the conventional wet well

Adapting circular sumps to sewage solids TOP 100 wet well Just 3 # of sand remained in the TOP 100 wet well

Adapting circular sumps to sewage solids 100.00% 90.00% 98.6% 80.00% % Sand remaining 70.00% 60.00% 50.00% 40.00% 30.00% 20.00% 10.00% 1.4% Sand 0.00% Conventional 5'-4" TOP 100

Program Conclusions 1 TOP sump design proven to be more effective in transporting all types of tested solids than the conventional sump Difference was greatest for settling and floating solids Sump bottom was the most important characteristic to affect transport Pump stop level in also an important factor, lower levels provide greater floating solids transport

Program Conclusions 2 Repeated pumping cycles at lower pump-off levels proved most effective Sump mixing device was effective in enhancing the transport of settling solids (sand, grit and sludge), especially in the conventional wet-well TOP sump proved even more effective in handling solids than the conventional wet-well equipped with a sump mixing device

Self-cleaning sumps: Installation types Retrofit applications Pre-engineered fiberglass pump stations Pre-engineered concrete pump stations

TOPS utilization

Retrofit application

Upgrade an existing circular pump station 1. Remove station mechanicals. 2. Hose-clean and vacuum clean station interior 3. Lay leveling bed of fairly dry concrete

4. Lower TOP station insert onto stiff concrete base

5. Seat and level basin. 6. Restrain basin 7. Fill void area with grout. (~ 3 yds)

60 0 8. Finish with grout at 45 0 to 60 0 to PS side-wall

Completed station 9. Re-install piping and mechanical equipment

Plan view: Typical completed self-cleaning lift station retrofit

Before Completed Retrofit

Self-Cleaning Current new construction, utilization methods

Fiberglass pre-engineered pump station

Concrete pre-engineered pump station

Conclusions 1 The IT sump design has proven to be far more effective in transporting all types of solids and rags than the traditional circular sump. The IT sump exhibited the greatest sump improvement: removal of floating type and settling type solids Sump diameter and bottom configuration are the characteristics that most affect the transport of solids

Conclusions 2 Pump off levels are an important factor in maintaining a clean wet-well The lower the sump level, the greater the amount of solids that are transported Repeated cycles of low pump-off levels proved to be most effective

Conclusions 3 A sump mixing device was very effective in enhancing the transport of settling solids and the prevention of grease build-up in the station The benefits of sump mixing were greatest in the traditional large diameter, flat bottom design sump

Conclusions 4 The IT sump w/o sump mixing device was significantly more effective at handling solids than the traditional sump The IT sump was even more effective when the mixing device was employed

Sump design recommendations for common circular concrete wet well 2 H H Elevation view

Sump design recommendations for common circular concrete wet well Plan view

Question and Answer Period

January 28, 2015 Innovative Technology: Development of the Self-cleaning Wet-well Robert Domkowski Engineering Consultant