To whom it may concern, February 21, 2011

Similar documents
Demonstration of Relationship between CO2 and ph Instructions

Evaluation copy. Chloride and Salinity. Computer INTRODUCTION

Ocean Water. Evaluation copy

LABORATORY INVESTIGATION

OCEAN ACIDIFICATION. Grade Level: This kit is appropriate for students in grades 6 12.

Sampling Day Activities

Hydrogen rich water bottle instruction manual. Model: PEM+

Project PARKA (Planting AntaRctica in KAnsas) Ocean Acidification: Whats and Hows

Forensics with TI-Nspire Technology

Biochemical Oxygen Demand

An Insulated Cola Bottle

Collecting a Surface Water Sample

Experiment B-38 Monitoring Yeast Growth

Dissolved Oxygen Probe (Order Code: DO-BTA)

seven mm screw top bottles Vernier computer interface shallow pan Vernier Dissolved Oxygen Probe scissors Logger Pro

Hydrogen rich water bottle instruction manual

Family Secrets. Part 4 Testing for the HD Gene

Photo tour of the monitoring activities found in the Stream Side Science manual

Human DNA Alu Amplification by Polymerase Chain Reaction (PCR)* Laboratory Procedure

Reverse Osmosis Purifiers

Phase Diagrams Revised: 1/27/16 PHASE DIAGRAMS. Adapted from Bill Ponder, Collin College & MIT OpenCourseWare INTRODUCTION

Solar Homes. Evaluation copy. empty bottle with screw-on cap

An Oxidation-Reduction Titration: The Reaction of Fe 2+ and Ce 4+

WESTPAC Training Workshop Research and Monitoring of the Ecological Impacts of Ocean Acidification on Coral Reef Ecosystems

edna PROTOCOL SAMPLE COLLECTION Caren Goldberg and Katherine Strickler, Washington State University Revised November 2015

A natural impurity in water. The test will measure the amount of free oxygen "gas" dissolved in your water sample in ppm (mg/l).

Dissolved Oxygen. LabQuest INTRODUCTION

A Water Field Study. Table 1: Water Temperatures of Selected Rivers Site Season Temperature ( C)

Basic Biotechnology Kit

Evaluation copy. Total Dissolved Solids. Computer INTRODUCTION

Collecting a Surface Water Sample

PLANS for the Chesapeake Bay A Teacher s Guide

With Discovery Incubator.

edna PROTOCOL SAMPLE COLLECTION Caren Goldberg and Katherine Strickler, Washington State University Revised January 2017

ecosphere water purifier 3in1 USER MANUAL

DETERMINATION of the EMPIRICAL FORMULA

FIELD PROCEDURE: TURBIDITY

Cell Respiration (Method 1 CO 2 and O 2 )

Instruction Manual HI Portable ph/ec/tds/ C Meters

Module 2, Add on Lesson Turbidity Sensor. Teacher. 90 minutes

Electroelution. Teachers Handbook. (Cat. # BE 602) think proteins! think G-Biosciences

HYDROLOGY INVESTIGATION Electrical Conductivity. What is Conductivity?

HEATING AND COOLING OF LAND AND WATER STANDARDS 3.1.7A 3.2.7B, 3.2.7C 3.5.7C, 3.5.7D 3.7.7A, 3.7.7B

EXTRA CREDIT - EXPERIMENT G ELECTROCHEMISTRY ACTIVITY OF METALS

Acid Rain. Evaluation copy. Figure 1: Typical rain ph in United States.

Chemistry 102 Freezing Point Depression Dr. Caddell. Depressing the Freezing Point of Cyclohexane

Enzyme Activity Lab. Grade 12 University Preparation Biology. Performed By:

LABORATORY INVESTIGATION Light and Photosynthesis - Teacher Instructions

Oyster ph - Conductivity - TDS - Temperature Meters

COPPER CYCLE EXPERIMENT 3

Quick Start Guide. Water Activity Data Logger System. Indoor Moisture Monitoring System

Lab #7H Photosynthesis and Respiration

Skills in Science. Lab equipment. (Always draw 2D) Drawings below are NOT to scale. Beaker - A general purpose container with a pouring lip.

Evaluation copy. Energy Content of Fuels. computer OBJECTIVES MATERIALS

One to two class periods depending on how much of the lab set-up is done before hand and the length of the pre-lab and follow-up discussions.

Part A: Carbonic Acid and CO2 Equilibrium

USER MANUAL. ExStik CL200A. Waterproof Total Residual Chlorine Tester. Patent Pending. Additional User Manual Translations available at

Just Passing Through. Suggested Grade Level 6-8. Estimated Time 45 minutes. Objectives Students will be able to:

A. Introduction. Figure 1 Figure 2

Experiment 13: Determination of Molecular Weight by Freezing Point Depression

Instruction Manual. HI HI Portable ph/ec/tds/ C Meters

The Varying Density of Sea Water Based on

D A T A L O G G I N G

APPENDIXES. Appendix 1A. Preparation of a 1% Agarose Gel for Gel Electrophoresis

Experiment: The Incredible Mass Lifting Heat Engine

HOBO U24 Conductivity Logger (U C) Manual

HOBO U24 Conductivity Logger (U C) Manual

Kansas Corn: Ethanol - Corn Mash and Distillation High School Student Lab Packet

BIOLOGY 163 LABORATORY. RESTRICTION MAPPING OF PLASMID DNA (Revised Fall 2017)

The following are the completed but unbalanced equations. Each equation is numbered to match each step of the cycle:

Vernier Software & Technology

Salinity Sensor PS Salinity Sensor Probe. Salinity Sensor Probe, 10 X, Conductivity/Temperature PASPORT Extension Cable

Methods and Materials Manual Of Ion Chromatography Using DX-100 IC. Collecting Samples. LDPE bottle with cap (pre-rinsed with DI water)

ESSENTIAL FOR SURVIVAL

User's Guide. ExStik CL200A. Waterproof Total Residual Chlorine Tester Patent Pending

Eutrophication Using Up Oxygen In Water

Module 2, Add on Lesson Conductivity Sensor. Student. 90 minutes

Thermo Scientific Orion Dissolved Oxygen Probes

Water-Water Titration for the MicroCal ITC200

HOBO U24 Conductivity Logger (U24-001) Manual

HOBO Plug Load Logger (UX ) Manual

MSES consultants, inc.

Module 2, Add on Lesson Conductivity Sensor. Teacher. 90 minutes

Kansas Corn: Fermenting Fuel- Designing a Procedure for Fast Fermentation

The Ocean Acidification Lab IV: CO 2 Concentration/Type of Water DV: Shell Strength/Color of Water

Standard Operating Procedure

Episode 608: Latent heat

Energy Conservation and Transformation

Cadmium Testing and On Site Calibration for Water Testing Detection Range: ppm

Zinc Testing and On Site Calibration for Water Testing Detection Range: 1 15ppm

Kansas Corn: Ethanol - Corn Mash and Distillation High School Student Lab Packet

Chem 355 Jasperse DISTILLATION

Geologic Sequestration Science

Algaculture & Biofuels: Exploration Experiments with Algae

Building a Thermometer

Refractometer Calibration, Use and Maintenance Stephen Vasquez and Shannon Mueller

Quick Start Guide. AquaLab TDL Water Activity Meter

Module 2, Add on Lesson Turbidity Sensor. Student. 90 minutes

Effect of Temperature on Cold-Blooded Organisms

Transcription:

To whom it may concern, February 21, 2011 The following is an evaluation of the GEMS grant that I received to start my own C-MORE lab kits, specifically ocean acidification, plankton, marine debris and ocean conveyor belt. I had to make some modifications on the ocean acidification lab kit due to equipment issues. The marine debris lab kit was just copying the information given to me, no equipment was needed. The plankton lab kit was used to collect plankton via a plankton net here in Guam but the product was not what I expected it to be. I had a preserved sample of plankton from Virginia which worked out well. The ocean conveyor belt lab kit worked out real well with the purchased salinity meter. We also used it to test other samples of water throughout the island. Overall the kits worked well with the power points and lab activities with worksheets. My students developed a greater understanding of the problems our oceans face. Thank you for the opportunity to develop these kits. Below are some pictures. Susan Hieter St. Johns School of Guam 911 N. Marine Corps Dr. Tumon, GU 96913 671-646-8080 OCEAN ACIDIFICATION OCEAN CONVEYOR BELT

STUDENT INSTRUCTIONS (ph & CO 2 group) Lesson 2: Yeast Experiment In this experiment, you will be activating yeast, which creates carbon dioxide (CO 2 ). The CO 2 gas will be bubbled into a sample of water, where you will measure how the ph of the water changes over time. The other members of your group will be doing the same experiment, but they will measure the change in CO 2 concentration over time in an air sample. At the end of the experiment, you will exchange data with the other members of your group. Set up the LabPro 1. First download the Logger Pro 3 disc onto your computer. Then, if you have windows 7 or windows vista, you need to go to the website (www.vernier.com ) to download the update. Click on downloads at the top, then click on Logger Pro 3.8.3 free update and down for your specific computer type. 2. The equipment you will use in this experiment is very expensive. Each set-up costs approximately $750, so make sure to treat the equipment with care. A LabPro (photo at right). 3. For the ph of the experiment, gather 1 packet of yeast, 2 packets or teaspoons of sugar, and the following items: ph probe 1 round 500 ml bottle 1 square 125 ml bottle 1 piece of rubber tubing connected with a straight connector at one end to a large, white stopper

4. Fill the square bottle to the black line with room temperature water. To remove the ph probe from its storage container, UNSCREW THE LID FIRST and then gently pull the sensor out of the top. Be careful not to spill the storage solution. Insert the sensor into the square bottle as in the photo to the right. The tip (blue end) of the probe should be submerged in the water. The rest of the probe should remain dry! It is NOT waterproof! 5. For the CO 2 of the experiment, gather 1 packet of yeast, 2 packets or teaspoons of sugar and the following items: CO 2 probe 1 round 500 ml bottle 1 BioChamber 1 piece of rubber tubing connected with straight connectors to a black stopper at one end and a black stopper at the other end 6. Make sure the CO 2 probe is set to high (switch is at the top of the probe). Place the CO 2 probe horizontally in the BioChamber. The bottle will be on its side, and the probe will enter the bottle through the bottle top, as in the photo at right. The CO 2 probe cannot get wet. Make sure it stays dry! 7. Collect your piece of rubber tubing with the stoppers at both ends. Place the black stopper in the hole in the side of the BioChamber, as in the photo at right. Make sure the seal is tight.

8. Open up your Logger Pro 3 on your computer. Plug in the LabPro with the electrical adapter to the electric outlet. Connect the ph probe to the port labeled CH1 on the side of the LabPro. Connect your CO 2 probe to the port labeled CH2. Connect the USB cord to your computer and let the computer/logger Pro 3 program read the CO 2 and ph levels. FOR THE CO 2 GRAPH, CLICK ON THE 5,000ppm AND CHANGE IT TO 100,000ppm. TO CHANGE THE TIME TO MINUTES, CLICK ON THE CLOCK ICON AND ENTER 24 MINUTES. 9. GENTLY swirl the ph probe in the water for 3 minutes; during this time the ph should rise. After 3 minutes, stop swirling. Watch the readings on the computer, and wait for the ph reading to settle. The ph reading should be stable for approximately 1 minute before beginning the experiment. It is very important that the sensor equilibrate, so be patient! The sensor should give a ph of approximately 6 8. The ph of pure water is 7, but tap water often contains harmless, dissolved minerals that can affect its ph. 10. As you are waiting for the sensors to equilibrate, make a prediction as to what will happen to the ph and CO 2 levels during the course of the experiment (question 1 on the STUDENT WORKSHEET). Activate the Yeast 11. You will start your experiment at the same time as the CO 2 group. When both groups have their equipment set up, fill your round 500 ml bottle up to the blue line with water that is hot to the touch. Your set-up should look like the picture below. 12. At the same time as the CO 2 group, use a paper funnel to add 2 packets or teaspoons of sugar to the hot water, and then add 1 packet of yeast. Stir by swirling the bottle for 5 seconds (This is the only time you need to stir the solution. Do not overmix!), then QUICKLY insert the both black, rubber stopper into the top of each bottle. Make sure the seal is tight. Place the attached rubber tubing into the room-temperature water with your ph sensor.

Data Collection 13. Record your initial ph and CO 2 readings from the computer in the table on your STUDENT WORKSHEET. The yeast solution should begin to foam as in the picture below. In a few minutes, the gas being produced by the yeast should travel through the rubber tubing, producing bubbles in the water where ph is being measured. If you do not observe bubbles after the yeast solution has started to foam, you probably have a leak in your bottle or tubing. Check your rubber stopper seal. 14. Follow the instructions on your STUDENT WORKSHEET for collecting your data. You will be making observations and recording the ph every 3 minutes. 15. When the foam reaches the black line on the bottle (or after 24 minutes whichever comes first), stop the experiment by removing the stopper from your bottle and unplug your probes from the LabPro. Do not let the foam pass the black line. When the foam reaches the black line, stop the experiment. Don't let the foam rise above the black line, as shown here! 16. After the experiment is over, click on the A icon which will automatically scale your graphs. Print your graphs if you desire to. 17. Rinse and dry the round 500ml bottles that had the yeast in it, the funnel, and the 125 ml bottle that had the water in it. DO NOT rinse the ph probe! To store the ph probe, make sure the cap of the storage bottle is unscrewed before inserting the probe through the cap, then tighten the cap back onto the storage bottle. The tip of the sensor should be immersed in the storage solution, but should not touch the bottom of the container. Throw away your empty yeast and sugar packets. Return all supplies to your teacher for inspection. Double check that all items are included. Please tell your teacher if there are any missing, broken, or damaged items so that they can be replaced.