CALCULATING WIND LOADS ON LOW-RISE STRUCTURES PER 2015 WFCM ENGINEERING PROVISIONS (STD342-1)

Similar documents
Wood Shear Wall Design Examples For Wind

130 MPH EXPOSURE B WFCM GUIDE. Guide to Wood Frame Construction in High Wind Areas for One- and Two-Family Dwellings 2015 EDITION

WFCM 120 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

WFCM 130 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

WFCM 90 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

WFCM 110 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

WFCM 100 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

WFCM 130 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

WFCM WORKBOOK 2012 EDITION. Wood Frame Construction Manual for One- and Two-Family Dwellings

ROOF FRAMING ANCHORAGE FORCES: MWFRS

Wood Frame Construction Manual for One- and Two-Family Dwellings 2015 EDITION WORKBOOK

2012 Wood Frame Construction Manual: Wind Speed and Design Pressure Determination According to ASCE 7 10

WFCM WOOD FRAME CONSTRUCTION MANUAL. WOOD FRAME CONSTRUCTION MANUAL for One- and Two-Family Dwellings AMERICAN WOOD COUNCIL

Impact of C&C loads due to ASCE/SEI Overview Revised 3/23/2017

A REPORT ON THE EFFECTS OF WIND SPEED ON TIMBER CONSTRUCTION JOSHUA HUENEFELD. B.S., Kansas State University, 2012 A REPORT

STRUCTURAL ISSUES IN RESIDENTIAL CONSTRUCTION. Presented by: Susan L. Lasecki P.E., S.E.

What is Conventional Construction?

DESIGN OF LOADBEARING TALL WOOD STUDS FOR WIND AND GRAVITY LOADS (DES230)

research report Cold-Formed Steel Gable End Wall Design Using the Prescriptive Method for One and Two Family Dwellings RESEARCH REPORT RP05-2

STD302: Wood Frame Construction Manual 2001 National Edition

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2014 LARC)

Wind Load Report - Check for uplift

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2011 LARC)

Considerations for Outof-Plane. Design

Wind Load Report - Naples Residence

2012 Wood Frame Construction Manual: Wind Load Distribution on Buildings Load Paths

NCMA TEK RESIDENTIAL DETAILS FOR HIGH WIND AREAS. TEK 5-11 Details (2003)

COMPANION FOR THE 2001

Load Design Charts. R-CONTROL SIPs STRUCTURAL INSULATED PANELS. CONTROL, NOT COMPROMISE.

Building Division Informational Handout

CHAPTER 3 BUILDINGS WITH WOOD FRAMED EXTERIOR WALLS 301 SCOPE

APPENDIX A1 WIND AND SEISMIC BRACING GUIDELINE FOR ONE AND TWO FAMILY DWELLINGS AND TOWNHOUSES

R Code and Commentary for 2012 NC Residential Code final 03/06/13

Lateral load basics Code acceptance of Standard. Standard Overview 2008 Wind & Seismic Standard. Wind. Wind Load Path. IBC Section 1604.

2012 IRC Wood Wall Bracing

SECTION R614 STRUCTURAL INSULATED PANEL WALL CONSTRUCTION

INGHOUSE Page 1 of 48

Heel Blocking Requirements and Capacity Analysis. Overview Revised 3/22/2017

International Code Council

2015 Special Design Provisions for Wind and Seismic Philip Line, P.E., John Buddy Showalter, P.E., Michelle Kam-Biron, P.E., S.E., Jason Smart, P.E.

COPYRIGHT MATERIALS. Wind Solutions - Perforated Wood Structural Panel Shear Walls (DES 416)

RB104-09/10 R602.7, R (New), Table R (New), Figures R (1)-(2) (New)

Table 3. Detailed Comparison of Structural Provisions of IRC 2000 and 1997 NEHRP (Continued)

R CODE CHANGE PROPOSAL FORM (See instructions on page 2)

MAT109: Introduction to the Wood Frame Construction Manual

Applying IBC 2000 wind and snow loads to post-frame building posts

LATERAL LOADS ON BRICK VENEER RESIDENTIAL STRUCTURES

U.S. WALL GUIDE. Featuring Trus Joist TimberStrand LSL and Parallam PSL Wall Framing. Engineered to meet code requirements for walls up to 30' tall

MBOIA IRC Wall Bracing. Mark Halverson. Maine Building Officials and Inspectors Association. First Last

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings

Structural Design for Wind Loads: An Overview of Engineering Considerations for Wood

Framing & Building Basics. Architectural Drawing & Interior Design

Section Downloads. Background. Load Development Outline. Types of Loads ANSI/ASCE 7. Section 07: Load Development. Download & Print. Version 2.

16.4 FLORIDA BUILDING CODE BUILDING

Featuring Selection and Installation Information for Lateral Wind Loads

STRUCTURAL DESIGN CRITERIA

City of Bemidji Building Office City Hall 317 4th Street NW Bemidji, Minnesota Phone Fax emi mn s

2001 California Building Code (1997 UBC) -vs California Building Code (2006 IBC)

City of Republic Community Development Girder and Header Spans for Exterior Walls

ADVANCED FRAMING LUMBER

Calculation of Wind Loads on Structures according to ASCE 7-10

Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses (MPCWT) Design Guide Revised 11/17/2016

Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses. DD No

WALL CONSTRUCTION CHAPTER 6

OUR COMPANY OUR WARRANTY OUR GUARANTEE

Chapter 2 EARTHQUAKE-RESISTANCE REQUIREMENTS

LPI 56 Technical Guide

Designing Wood Frame Structures For High Winds. Ricky McLain, MS, PE, SE Technical Director WoodWorks SEAMASS Meeting

VOLUNTARY - EARTHQUAKE HAZARD REDUCTION IN EXISTING HILLSIDE BUILDINGS (Division 94 Added by Ord. No. 171,258, Eff. 8/30/96.)

Frame Wood Systems. Prepared for Forest Product Laboratory, Forest Service, U.S. Department of Agriculture National Association of Home Builders

Frame Wood Systems. Prepared for Forest Product Laboratory, Forest Service, U.S. Department of Agriculture National Association of Home Builders

GARAGES/ONE-STORY City of Grand Rapids Building Safety Division

Version 2.1 IBS 2010 Special Resource Edition

Individual Truss Marking Is it a Building Code Requirement?

PRESENTATION OUTLINE MUBEC & IRC APPLICABILITY & ADMIN. 6/17/2015 RESIDENTIAL STRUCTURAL SYSTEMS. Carmen B. Bombeke, P.E.

Fundamentals of Wood Design and Engineering

PRODUCT: Structural Insulated Panels (SIP) DIVISION: Wood and Plastics (06) SECTION: Structural Panels ( )

WIND LOADS ON BUILDINGS MWFRS (ENVELOPE PROCEDURE)

FIGURE R502.2 FLOOR CONSTRUCTION

5 Load Determination and Structural Design Criteria

Wall bracing panel requirements

APPENDIX. WOOD JOIST/RAFTER MAXIMUM SPANS ( for 16 o.c. spacing) WITH SINGLE ROW OF PV PANELS AT MIDSPAN (ft.) AND PANEL SUPPORT AT 32 o.c.

WIND & SEISMIC 2008 EDITION ASD/LRFD WITH COMMENTARY. American Forest & Paper Association. American Wood Council ANSI/AF&PA SDPWS-2008

Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses (MPCWT) Overview Revised 11/17/2016

GLOBAL LVL HEADERS, BEAMS AND COLUMNS. 1.9E-2850Fb. 1.9E-2850Fb. User guide User guide. lvlglobal.com

WIND & SEISMIC 2008 EDITION ASD/LRFD WITH COMMENTARY. American Forest & Paper Association. American Wood Council ANSI/AF&PA SDPWS-2008

Appendix I ESTIMATED DESIGN WIND PRESSURE AND STRENGTHS OF CONNECTIONS OF JOPLIN HOME DEPOT BUILDING

(b) Calculate the required nominal axial compression strength, Pn of the column.

Joint Evaluation Report

Joint Evaluation Report

STRUCTURAL DESIGN CRITERIA

SECTION PLATE CONNECTED WOOD TRUSSES

Figure 1 Shear wall segments with mono-sloped top plates

LVL Product Guide 2.0E LVL 1.5E LVL

PRODUCT: Structural Insulated Panels (SIPs) DIVISION: Wood and Plastics (06) SECTION: Structural Panels ( )

Residential Wood Deck Design

BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS

Murphy LVL Limit States Design Guide 2.0 E-LVL 2.2 E-LVL

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: LAMINATED VENEER LUMBER REPORT HOLDER: REDBUILT LLC EVALUATION SUBJECT:

OVERALL STRUCTURAL SYSTEM

Transcription:

CALCULATING WIND LOADS ON LOW-RISE STRUCTURES PER 015 WFCM ENGINEERING PROVISIONS (STD34-1) John Buddy Showalter, P.E. Vice President, Technology Transfer American Wood Council Description The Wood Frame Construction Manual (WFCM) for One- and Two-Family Dwellings (ANSI/AWC WFCM-015) is referenced in the 015 International Building Code and 015 International Residential Code. For WFCM wind load calculations, Minimum Design Loads for Buildings and Other Structures (ASCE 7-10) is used. The 015 WFCM includes design information for buildings located in regions with 700-year return period three second gust design wind speeds between 110 and 195 mph. ASD wind pressures for Main Wind-Force Resisting Systems (MWFRS) and Components and Cladding (C&C) are computed. Shear, uplift, and overturning loads are calculated for various building components. WFCM Chapter provides minimum loads for the purpose of establishing specific resistance requirements for buildings within the scope of the document. This presentation will provide background and examples for calculation of these forces which will enable designers and code officials to quickly determine wind design loads for projects. Learning Objectives Upon completion of this webinar, participants will: 1. Understand applicable wind loads from ASCE 7-10 for structures within the WFCM scope.. Be familiar with application of MWFRS versus C&C loads for various building components and systems. 3. Be familiar with shear, uplift, and overturning wind loads for various building components. 4. Be familiar with tabulated values and their basis in WFCM Chapter for wind loads.

GENERAL INFORMATION Table 1 Applicability Limitations Attribute Limitation Reference Section Figures BUILDING DIMENSIONS Mean Roof Height (MRH) 33' 1.1.3.1a 1. Number of Stories 3 1.1.3.1a Building Length and Width 80' 1.1.3.1b Partition Dead Load Wall Assembly Dead Load Floor Dead Load Roof/Ceiling Assembly Dead Load Floor Live Load Roof Live Load Ceiling Live Load Ground Snow Load Wind Load Seismic Load LOAD ASSUMPTIONS (See Chapter or Chapter 3 tables for load assumptions applicable to the specific tabulated requirement) Load Type Load Assumption 0 8 psf of floor area 11 18 psf 10 0 psf 0 5 psf 30 40 psf 0 psf 10 0 psf 0 70 psf 110 195 mph wind speed (700 yr. return period, 3 second gust) Exposure B, C, and D Seismic Design Category (SDC) SDC A, B, C, D 0, D 1, and D

WOOD FRAME CONSTRUCTION MANUAL 11 Figure 1.1 Basic Wind Speeds for One- and Two-Family Dwellings Based on 700 yr Return Period 3-second Gust Basic Wind Speeds 1 GENERAL INFORMATION (from ASCE 7-10 Figure 6.5-1A with permission from ASCE)

WOOD FRAME CONSTRUCTION MANUAL 15.1 General Provisions.1.1 Engineered Requirements The provisions of this Chapter provide minimum loads for the purpose of establishing specific resistance requirements for buildings within the scope of this document. This Chapter includes the results of engineering calculations for specific structural elements, in specific configurations, under specific loads. The tabulated information does not represent a complete engineering analysis as would be performed by a registered professional engineer, but is expected to result in significant time-savings for the design professional..1. Continuous Load Path A continuous load path shall be provided to transfer all lateral and vertical loads from the roof, wall, and floor systems to the foundation..1.3 Engineered Design Limitations Wood-frame buildings built in accordance with this document shall be limited to the conditions of this section (see Table ). Structural conditions not complying with this section shall be designed in accordance with accepted engineering practice..1.3.1 Adjustment for Wind Exposure and Mean Roof Height Tabulated wind requirements in this chapter are based on wind exposure category B and a mean roof height of 33 feet. The building shall neither exceed three stories nor a mean roof height of 33 feet, measured from average grade to average roof elevation (see Figure 1.). Additional loads from habitable attics shall be considered for purposes of determining gravity and seismic loads. For buildings sited in exposure category C or D, wind-related tabulated values shall be increased in accordance with specific adjustments as provided in table footnotes or per Table.1.3.1..1.3. Floor Systems a. Framing Member Spans Single spans of floor framing members shall not exceed 6 feet for lumber joists, I-joists, and floor trusses. Design spans shall consider both strength and serviceability limits. For serviceability, the computed joist deflection under live load shall not exceed L/360 (span divided by 360) or more stringent criteria as specified by the manufacturer. Table.1.3.1 Mean Roof Height (feet) Adjustment for Wind Exposure and Mean Roof Height Exposure B Exposure C Exposure D 0-15 1.00 1.18 1.43 0 1.00 1.5 1.50 5 1.00 1.31 1.56 30 1.00 1.36 1.61 33 1.00 1.39 1.64 b. Framing Member Spacings Floor framing member spacings shall not exceed 4 inches on center for lumber joists, I-joists, and floor trusses. c. Cantilevers Lumber floor joist cantilevers supporting loadbearing walls shall not exceed the depth, d, of the joists (see Figure.1a). Lumber floor joist cantilevers supporting non-loadbearing walls shall be limited to L/4 (see Figure.1b). I-joist cantilevers shall be in accordance with the manufacturer s code evaluation report. Truss cantilevers shall be in accordance with the truss design/ placement plans. Lumber joists, I-joists, and trusses shall be located directly over studs when used in cantilever conditions, unless the top plate is designed to carry the load. EXCEPTION: Lumber floor joist cantilevers supporting loadbearing walls shall be permitted to exceed these limits when designed for the additional loading requirements, but in no case shall they exceed four times the depth (4d) of the member (see Figure.1c). d. Setbacks Setbacks of loadbearing walls on lumber floor joist systems shall not exceed the depth, d, of the joists (see Figure.1d). Setbacks on I-joists shall be in accordance with the manufacturer s code evaluation report. Setbacks on floor trusses shall be in accordance with the truss design/placement plans. Lumber joists, I-joists, and trusses shall be located directly over studs when used in setback conditions supporting loadbearing walls, unless the top plate is designed to carry the load. EXCEPTION: Lumber floor joist setbacks supporting loadbearing walls shall be permit- ENGINEERED DESIGN

WOOD FRAME CONSTRUCTION MANUAL 35 Figure.a Typical Lateral Framing Connections Cross Sec on End View Ra er Ceiling Joist ENGINEERED DESIGN Stud Floor Joist Stud Floor Joist

36 ENGINEERED DESIGN Figure.b Shear Connection Locations

WOOD FRAME CONSTRUCTION MANUAL 37 Figure.c Typical Wind Uplift Connections Cross Sec on End View Ra er Ceiling Joist ENGINEERED DESIGN Stud Floor Joist Stud Floor Joist

38 ENGINEERED DESIGN Figure.d Overturning Detail

GENERAL INFORMATION C1.1 Scope C1.1.1 General The scope statement limits applicability of the provisions of the Wood Frame Construction Manual to one- and two-family dwellings. This limitation is related primarily to assumed design loads and to structural configurations. Code prescribed floor design loads for dwellings generally fall into the range of 30 to 40 psf, with few additional requirements such as concentrated load provisions. In these applications, use of closely spaced framing members covered by structural sheathing has proven to provide a reliable structural system. C1.1. Design Loads Unless stated otherwise, all calculations are based on standard linear elastic analysis and Allowable Stress Design (ASD) load combinations using loads from ASCE 7-10 Minimum Design Loads for Buildings and Other Structures. Dead Loads Unless stated otherwise, tabulated values assume the following dead loads: Roof 10 psf Ceiling Floor Walls Partitions 5 psf 10 psf 1 psf (for Seismic) 11 psf 8 psf (for Seismic) Live Loads Unless stated otherwise, tabulated values assume the following live loads: Roof 0 psf Floor (sleeping areas) Floor (living areas) 30 psf 40 psf Wind Loads Wind forces are calculated assuming a box-like structure with wind loads acting perpendicular to wall and roof surfaces. Lateral loads flow into roof and floor diaphragms and are transferred to the foundation via shear walls. Roof uplift forces are transferred to the foundation by direct tension through the wall framing and tension straps or wall sheathing. Shear wall overturning forces are resisted by the structure s dead load and by supplemental hold down connections. Implicit in the assumption of a box-like structure is a roughly rectangular shape, relatively uniform distribution of shear resistance throughout the structure, and no significant structural discontinuities. In addition, the buildings are assumed to be enclosed structures in which the structural elements are protected from the weather. Partially enclosed structures are subjected to loads that require further consideration. For wind load calculations, ASCE 7-10 is used. ASCE 7-10 calculations are based on 700-year return period three second gust wind speeds corresponding to an approximate 7% probability of exceedence in 50 years, and use combined gust and pressure coefficients to translate these wind speeds into peak design pressures on the structure. The 015 WFCM includes design information for buildings located in regions with 700-year return period three second gust design wind speeds between 110 and 195 mph. Basic Design Equations: ASD wind pressures, p max, for Main Wind-Force Resisting Systems (MWFRS) and Components and Cladding (C&C) are computed by the following equations, taken from ASCE 7-10: MWFRS Envelope Procedure: p max = q[(gc pf ) (GC pi )] (lbs/ft ) where: q = 0.60 q h q h = 0.0056K z K zt K d V (ASCE 7-10 Equation 8.3-1) GC pf = external pressure coefficients (ASCE 7-10 Figure 8.4-1) GC pi = internal pressure coefficients (ASCE 7-10 Table 6.11-1) C&C: p max = q[(gc p ) (GC pi )] (lbs/ft ) where: q = 0.60q h q h = 0.0056K z K zt K d V (ASCE 7-10 Equation 30.3-1) GC p = external pressure coefficients (ASCE7-10 Figures 30.4-1,30.4-A, B, &C) GC pi = internal pressure coefficients (ASCE 7-10 Table 6.11-1) The calculation of ASD velocity pressure, q, for various wind speeds and Exposures is shown in Table C1.1.

COMMENTARY TO THE WOOD FRAME CONSTRUCTION MANUAL 3 Table C1.1 ASD Velocity Pressure, q (psf), for Exposures B, C, and D and 33' MRH Exposure Category ASD Velocity Pressure, q (psf) 700-yr. Wind Speed 3-second gust (mph) 110 115 10 130 140 150 160 170 180 195 Exposure B 11.37 1.43 13.54 15.89 18.4 1.15 4.06 7.17 30.46 35.74 Exposure C 15.80 17.7 18.80.06 5.59 9.38 33.4 37.73 4.30 49.65 Exposure D 18.64 0.37.18 6.04 30.0 34.66 39.44 44.5 49.9 58.58 and q = 0.6 q h q h = 0.0056 K z K zt K d V K z (33 ft) = 0.7 K zt = 1.0 ASCE 7-10 Table 8.3-1 (MWFRS), Table 30.3-1(C&C) at mean roof height (MRH) of 33 ft No topographic effects K d = 0.85 ASCE 7-10 Table 6.6-1 1 GENERAL INFORMATION Design wind pressures in ASCE 7-10 are based on an ultimate 700-year return period. Since the WFCM uses allowable stress design, forces calculated from design wind pressures are multiplied by 0.60 in accordance with load combination factors per ASCE 7-10. For example, the ASD velocity pressure, q, at 150 mph for Exposure B is calculated as follows: q = 0.6 (0.0056)(0.7)(1.0)(0.85)(150) (lbs/ft ) = 1.15 (lbs/ft ) In order to use the 015 WFCM with basic wind speeds from the 015 International Residential Code (IRC), see the wind speed conversion Table C1. based on the following calculations: Equating wind pressures calculated using ASCE 7-10 wind speeds with those from the 015 IRC. Velocity pressure for the ASCE 7-05 basic wind speed of 90 mph (Exposure B) is calculated as follows: q = 0.0056(0.7)(0.85)90 = 1.7 psf ASD velocity pressure using the ASCE 7-10 wind speed of 116 mph (Exposure B) is calculated as follows: q = (0.60)[0.0056(0.7)(0.85)116 ] = 1.7 psf On the basis of equating wind pressures, the 90 mph ASCE 7-05 basic wind speed is equivalent to the 116 mph ASCE 7-10 basic wind speed. Table C1. Wind Speed Conversion Table ASCE 7-05 Basic Wind Speeds (mph) 85 90 100 110 10 130 140 150 Equivalent ASCE 7-10 Basic Wind Speeds (mph) 110 116 19 14 155 168 181 194 Wind speed contour maps in the 015 IRC show the 90 mph contour as covering approximately the same geographical area as that for the 115 mph wind speed contour in ASCE 7-10. The velocity pressure for the 115 mph (Exposure B) ASCE 7-10 wind speed (1.4 psf) however, is slightly less than the velocity pressure corresponding to the 90 mph 015 IRC (Exposure B) wind speed (1.7 psf). Note that the worst case of internal pressurization is used in design. Internal pressure and internal suction for MWFRS are outlined in WFCM Tables C1.3A and C1.3B, respectively. Pressure coefficients and loads for wind parallel and perpendicular to ridge are tabulated. Parallel to ridge coefficients are used to calculate wind loads acting perpendicular to end walls. Perpendicular-toridge coefficients are used to calculate wind loads acting perpendicular to side walls. Pressures resulting in shear, uplift, and overturning forces are applied to the building as follows:

4 GENERAL INFORMATION Shear Calculations The horizontal component of roof pressures is applied as a lateral load at the highest ceiling level (top of the uppermost wall). Windward and leeward wall pressures are summed and applied (on a tributary area basis) as lateral loads at each horizontal diaphragm. For example, in typical two story construction, one-half of the height of the top wall goes to the roof or ceiling level, a full story height goes to intermediate floor diaphragms (one-half from above and one-half from below) and one-half of the bottom story goes directly into the foundation. Lateral roof and wall pressures for determining diaphragm and shear wall loads are calculated using enveloped MWFRS coefficients. Spatially-averaged C&C coefficients are used for determining lateral framing loads, suction pressures on wall and roof sheathing, and exterior stud capacities. Uplift Calculations Uplift for roof cladding is calculated using C&C loads. Uplift connections for roof framing members are calculated using enveloped MWFRS loads. The rationale for using MWFRS loads for computing the uplift of roof assemblies recognizes that the spatial and temporal pressure fluctuations that cause the higher coefficients for components and cladding are effectively averaged by wind effects on different roof surfaces. The uplift load minus sixty percent of the roof and/or ceiling dead load is applied at the top of the uppermost wall. As this load is carried down the wall, the wall dead load is included in the analysis. The dead load from floors framing into walls is not included, in order to eliminate the need for special framing details where floors do not directly frame into walls. Overturning Calculations Overturning of the structure as a result of lateral loads is resisted at the ends of shear walls in accordance with general engineering practice, typically with hold downs or other framing anchorage systems. In the WFCM, overturning loads are differentiated from uplift loads. Overturning moments result from lateral loads which are resisted by shear walls. Uplift forces arise solely from uplift on the roof, and are transferred directly into the walls supporting the roof framing. ASCE 7-10 requires checking the MWFRS with a minimum 5 psf ASD lateral load on the vertical projected area of the roof and a 10 psf ASD lateral load on the wall. The 015 WFCM incorporates this design check. Snow Loads The 015 WFCM includes design information for snow loads in accordance with ASCE 7-10 for buildings located in regions with ground snow loads between 0 and 70 psf. Both balanced and unbalanced snow load conditions are considered in design. Seismic Loads The 015 WFCM includes seismic design information in accordance with ASCE 7-10 for buildings located in Seismic Design Categories A-D, as defined by the 015 IRC. C1.1..1 Torsion Design for torsion is outside the scope of this document. C1.1.. Sliding Snow Design for sliding snow is outside the scope of this document. C1.1.3 Applicability C1.1.3.1 Building Dimensions a. Mean Roof Height Building height restrictions limit the wind forces on the structure, and also provide assurance that the structure remains low-rise in the context of wind and seismic-related code requirements. The tables in the WFCM are based on wind calculations assuming a 33 ft mean roof height, (MRH). This assumption permits table coverage up to a typical 3-story building. Footnotes have been provided to adjust tabulated requirements to lesser mean roof heights. b. Building Length and Width Limiting the maximum building length and width to 80 feet is provided as a reasonable upper limit for purposes of tabulating requirements in the WFCM. C1.1.3. Floor, Wall, and Roof Systems See C.1.3. (Floor Systems), C.1.3.3 (Wall Systems), and C.1.3.4 (Roof Systems). C1.1.4 Foundation Provisions Design of foundations and foundation systems is outside the scope of this document. C1.1.5 Protection of Openings Wind pressure calculations in the WFCM assume that buildings are fully enclosed and that the building envelope is not breached. Interior pressure coefficients, GCpi, of +/-0.18 are used in the calculations per ASCE 7-10 Table 6.11-1. Penetration of openings (e.g. windows and doors) due to flying debris can occur in sites subject to high winds with a significant debris field. Where these areas occur,

COMMENTARY TO THE WOOD FRAME CONSTRUCTION MANUAL 5 opening protection or special glazing requirements may be required by the local authority to ensure that the building envelope is maintained. C1.1.6 Ancillary Structures Design of ancillary structures is outside the scope of this document. 1 Table C1.3A ASCE 7-10 Exposure B Main Wind-Force Resisting System (MWFRS) Loads, p (psf), for an Enclosed Building, 33' Mean Roof Height with Internal Pressure, 150 mph (700-yr. 3-second gust), Exposure B q = 1.15 psf (See Table C1.1) GENERAL INFORMATION with internal pressure Interior Zones Exterior Zones Roof Angle 1 3 4 5 6 1E E 3E 4E 5E 6E GC pf 0.40-0.69-0.37-0.9 0.40-0.9 0.61-1.07-0.53-0.43 0.61-0.43 0-5 GC pi 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 p (psf) 4.65-18.40-11.63-9.94 4.65-9.94 9.09-6.44-15.0-1.90 9.09-1.90 0 GC pf 0.53-0.69-0.48-0.43 0.40-0.9 0.80-1.07-0.69-0.64 0.61-0.43 GC pi 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 p (psf) 7.40-18.40-13.96-1.90 4.65-9.94 13.11-6.44-18.40-17.34 9.09-1.90 6.6 (6:1) GC pf 0.55-0.10-0.45-0.39 0.40-0.9 0.73-0.19-0.58-0.53 0.61-0.43 GC pi 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 p (psf) 7.8-5.84-13.6-1.06 4.65-9.94 11.58-7.73-16.17-15.11 9.09-1.90 30-45 GC pf 0.56 0.1-0.43-0.37 0.40-0.9 0.69 0.7-0.53-0.48 0.61-0.43 GC pi 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 p (psf) 8.04 0.63-1.90-11.63 4.65-9.94 10.79 1.90-15.0-13.96 9.09-1.90 90 GC pf 0.56 0.56-0.37-0.37 0.40-0.9 0.69 0.69-0.48-0.48 0.61-0.43 GC pi 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 p (psf) 8.04 8.04-11.63-11.63 4.65-9.94 10.79 10.79-13.96-13.96 9.09-1.90

6 GENERAL INFORMATION Table C1.3B ASCE 7-10 Exposure B Main Wind-Force Resisting System (MWFRS) Loads, p (psf), for an Enclosed Building, 33' Mean Roof Height with Internal Suction, 150 mph (700-yr. 3-second gust), Exposure B q = 1.15 psf (See Table C1.1) with internal suction Interior Zones Exterior Zones Roof Angle 1 3 4 5 6 1E E 3E 4E 5E 6E GC pf 0.40-0.69-0.37-0.9 0.4-0.9 0.61-1.07-0.53-0.43 0.61-0.43 0-5 GC pi -0.18-0.18-0.18-0.18-0.18-0.18-0.18-0.18-0.18-0.18-0.18-0.18 p (psf) 1.7-10.79-4.0 -.33 1.7 -.33 16.71-18.8-7.40-5.9 16.71-5.9 0 6.6 (6:1) GC pf 0.53-0.69-0.48-0.43 0.4-0.9 0.8-1.07-0.69-0.64 0.61-0.43 GC pi -0.18-0.18-0.18-0.18-0.18-0.18-0.18-0.18-0.18-0.18-0.18-0.18 p (psf) 15.0-10.79-6.35-5.9 1.7 -.33 0.73-18.8-10.79-9.73 16.71-5.9 GC pf 0.55-0.10-0.45-0.39 0.40-0.9 0.73-0.19-0.58-0.53 0.61-0.43 GC pi -0.18-0.18-0.18-0.18-0.18-0.18-0.18-0.18-0.18-0.18-0.18-0.18 p (psf) 15.44 1.78-5.65-4.45 1.7 -.33 19.19-0.1-8.55-7.50 16.71-5.9 30-45 GC pf 0.56 0.1-0.43-0.37 0.4-0.9 0.69 0.7-0.53-0.48 0.61-0.43 GC pi -0.18-0.18-0.18-0.18-0.18-0.18-0.18-0.18-0.18-0.18-0.18-0.18 p (psf) 15.65 8.5-5.9-4.0 1.7 -.33 18.40 9.5-7.40-6.35 16.71-5.9 90 GC pf 0.56 0.56-0.37-0.37 0.4-0.9 0.69 0.69-0.48-0.48 0.61-0.43 GC pi -0.18-0.18-0.18-0.18-0.18-0.18-0.18-0.18-0.18-0.18-0.18-0.18 p (psf) 15.65 15.65-4.0-4.0 1.7 -.33 18.40 18.40-6.35-6.35 16.71-5.9

WOOD FRAME CONSTRUCTION MANUAL 61 List of Tables.1 Lateral Framing Connection Loads from Wind... 6.A Uplift Connection Loads from Wind... 63.B Ridge Connection Loads from Wind... 64.C Rake Overhang Outlooker Uplift Connection Loads... 65.3 Thrust Connection Loads... 66.4 Roof and Wall Sheathing Suction Loads... 67.5A Lateral Diaphragm Loads from Wind - Perpendicular to Ridge... 68.5B Lateral Diaphragm Loads from Wind - Parallel to Ridge... 69.5C Lateral Diaphragm Loads from Wind - Parallel to Ridge (Attic/Floor/Ceiling)... 71.6 Lateral Loads from Seismic... 73.7A Floor Joist Spans for 30 psf Live Load... 74.7B Floor Joist Spans for 40 psf Live Load... 75.7C Floor Joist Bearing Stresses for Floor Loads... 76.8A Floor Framing Capacity Requirements for 30 psf Live Load... 77.8B Floor Framing Capacity Requirements for 40 psf Live Load... 78.9A Exterior Wall Stud Bending Stresses from Wind Loads... 80.9B Exterior Wall Stud Compression Stresses... 8.9C Interior Loadbearing Wall Stud Compression Stresses from Live Loads... 84.10 Exterior Wall Induced Moments from Wind Loads... 85.11 Loadbearing Wall Loads from Snow or Live Loads... 86.1A1- Ceiling Joist Spans for 10 psf Live Load... 87.1B1- Ceiling Joist Spans for 0 psf Live Load... 89.13A1- Ceiling Joist Framing Capacity Requirements (without storage)... 91.13B1- Ceiling Joist Framing Capacity Requirements (with limited storage)... 93.14A Rafter Spans for 0 psf Live Load... 96.14B Rafter Spans for 30 psf Ground Snow Load... 99.14C Rafter Spans for 50 psf Ground Snow Load... 100.14D Rafter Spans for 70 psf Ground Snow Load... 101.15A Roof Framing Capacity Requirements for 0 psf Roof Live Load... 103.15B Roof Framing Capacity Requirements for 30 psf Ground Snow Load... 106.15C Roof Framing Capacity Requirements for 50 psf Ground Snow Load... 107.15D Roof Framing Capacity Requirements for 70 psf Ground Snow Load... 108.16 Ridge Beam Capacity Requirements for Interior Center Bearing Roof and Ceiling.. 110.17 Hip and Valley Beam Capacity Requirements...111 ENGINEERED DESIGN

6 ENGINEERED DESIGN Table.1 Lateral Framing Connection Loads from Wind (For Roof-to-Plate, Plate-to-Plate, Plate-to-Stud, and Plate-to-Floor) 700 yr. Wind Speed 3 second gust (mph) 1 Wall Height (ft) 110 115 10 130 140 150 160 170 180 195 Unit Framing Loads (plf) 1,,3,4 8 67 73 79 93 108 14 141 159 178 09 10 79 87 94 111 19 148 168 190 1 49 1 91 100 109 18 148 170 193 18 45 87 14 103 11 1 144 167 191 18 46 75 33 16 114 14 135 159 184 1 41 7 305 358 18 14 136 148 174 01 31 63 97 333 391 0 135 147 160 188 18 50 85 31 360 43 Tabulated framing loads shall be permitted to be multiplied by 0.9 for framing not located within 3 feet of corners for buildings less than 30 feet in width (W), or within W/10 of corners for buildings greater than 30 feet in width. 3 4 Tabulated framing loads assume a building located in Exposure B with a mean roof height of 33 feet. For buildings located in other exposures, tabulated values shall be multiplied by the appropriate adjustment factor in Section.1.3.1. Tabulated framing loads are specified in pounds per linear foot of wall. To determine connection requirements, multiply the tabulated unit lateral framing load by the multiplier from the table below corresponding to the spacing of the connection: Connection Spacing (in.) 1 16 19. 4 48 Multiplier 1.00 1.33 1.60.00 4.00 When calculating lateral loads for ends of headers, girders, and window sills, multiply the tabulated unit lateral load by ½ of the header, girder, or sill span (ft).

COMMENTARY TO THE WOOD FRAME CONSTRUCTION MANUAL 13 Table.1 Lateral Framing Connection Loads from Wind Description: Lateral framing connection loads at base and top of wall expressed in pounds per linear foot of wall length. Procedure: Compute the lateral framing connection load at the top and bottom of studs based on tributary wind loads, using external (end zone) components and cladding pressure coefficients and internal pressure coefficients for enclosed buildings. Background: Components and cladding (C&C) coefficients result in higher wind loads relative to main wind force resisting system (MWFRS) coefficients. When determining C&C pressure coefficients (GC p ), the effective wind area equals the tributary area of the framing member. For long and narrow tributary areas, the area width may be increased to one-third the framing member span to account for actual load distributions. This results in lower average wind pressures. The increase in width applies only to calculation of wind force coefficients. Example: Given -150 mph, Exposure B, 33' MRH, 10' wall height, 16" o.c. connection spacing. The internal pressure coefficient (GC pi ) is taken from ASCE 7-10 Table 6.11-1. therefore: GC pi = +/- 0.18 p max = 1.15 (-1. - 0.18) = -9.61 psf (Negative pressure denotes suction) The pressure is multiplied by half the stud height to obtain the unit lateral framing connection load: = -9.61(10/) = -148 plf (WFCM Table.1) Required capacity of lateral framing connections spaced at 16" o.c. is: = 148plf (16 in./1 in./ft) = 197 lbs = 148 (1.33) (WFCM Table.1 Footnote 3) Footnote 1: Lateral framing connection loads are based on End Zone Coefficients (Zone 5) per the figure of Table.4. Where Interior Zones (Zone 4) occur, connection loads may be reduced. Adjustment of tabulated loads are conservatively based on a 0' wall height where A = 133 ft. ENGINEERED DESIGN p max = qgc p - qgc pi where: p max = pressure on the wall q = 1.15 psf (See Table C1.1) GC p = external pressure coefficients for C&C GC pi = +/- 0.18 internal pressure coefficient for enclosed buildings Stud tributary area equals 13.3 ft. The minimum required area for analysis is h /3=33.3 ft. The GC p equation is determined using ASCE 7-10 Figure 30.4-1. End Zones (See Zone 5 as shown in WFCM Table.4): GC p = -1.4 for A 10 ft GC p = -0.8-0.6[(log(A/500)) / (log (10/500))] for 10 < A 500 ft GC p = -0.8 for A > 500 ft therefore: End Zone GC p = -0.8-0.6[(log(A/500)) / (log (10/500))] = -0.8-0.6[(log(133/500)) / (log(10/500))] = -1.00 Interior Zone GC p = -0.8-0.3[(log(A/500)) / (log(10/500))] = -0.8-0.3[(log(133/500)) / (log(10/500))] = -0.9 The ratio of Zone 4 to Zone 5 loads is: (-0.9-0.18) / (-1.0-0.18) = 0.9 (WFCM Table.1 Footnote 1) Therefore, Interior Zone loads may be reduced to 9% of tabulated values. GC p = -0.8-0.6[(log(33.3/500)) / (log (10/500))] GC p = -1.

WOOD FRAME CONSTRUCTION MANUAL 63 Table.A Uplift Connection Loads from Wind (For Roof-to-Wall, Wall-to-Wall, and Wall-to-Foundation) 700 yr. Wind Speed 3 second gust (mph) 110 115 10 130 140 150 160 170 180 195 Roof/Ceiling Assembly Design Dead Load Roof Span (ft) Unit Connection Loads (plf) 1,,3,4,5,6,7 1 118 18 140 164 190 19 49 81 315 369 4 195 13 3 7 315 36 41 465 51 61 0 psf 8 36 7 98 34 380 441 506 576 650 79 856 48 350 383 417 489 567 651 741 836 938 1100 60 48 468 509 598 693 796 906 10 1146 1345 1 70 80 9 116 14 171 01 33 67 31 4 111 19 148 188 31 78 38 381 437 58 10 psf 36 15 178 04 60 31 386 456 530 609 736 48 194 7 61 333 411 495 585 680 78 944 60 36 76 317 406 501 604 714 830 954 1153 1 46 56 68 9 118 147 177 09 43 97 4 69 87 106 146 189 36 86 339 395 486 15 psf 36 9 118 144 00 61 36 396 470 549 676 48 116 149 183 55 333 417 507 60 704 866 60 140 180 1 310 405 508 618 734 858 1057 1 3 44 68 94 13 153 185 19 73 4 7 45 64 104 147 194 44 97 353 444 0 psf 36 3 58 84 140 01 66 336 410 489 616 48 38 71 105 177 55 339 49 54 66 788 60 44 84 15 14 309 41 5 638 76 961 1 8 0 44 70 99 19 161 195 49 4 3 6 105 15 0 55 311 40 5 psf 36 4 80 141 06 76 350 49 556 48 7 99 177 61 351 446 548 710 60 9 118 13 316 46 54 666 865 1 Tabulated unit uplift connection loads shall be permitted to be multiplied by 0.75 for framing not located within 6 feet of corners for buildings less than 30 feet in width (W), or W/5 for buildings greater than 30 feet in width. 3 4 5 6 7 8 Tabulated uplift loads assume a building located in Exposure B with a mean roof height of 33 feet. For buildings located in other exposures, the tabulated values for 0 psf roof dead load shall be multiplied by the appropriate adjustment factor in Section.1.3.1 then reduced by the appropriate design dead load. Tabulated uplift loads are specified in pounds per linear foot of wall. To determine connection requirements, multiply the tabulated unit uplift load by the multiplier from the table below corresponding to the spacing of the connectors: Connection Spacing (in.) 1 16 19. 4 48 Multiplier 1.00 1.33 1.60.00 4.00 Tabulated uplift loads equal total uplift minus 0.6 of the roof/ceiling assembly design dead load. Tabulated uplift loads are specified for roof to wall connections. When calculating uplift loads for wall to wall or wall to foundation connections, tabulated uplift values shall be permitted to be reduced by 73 plf (0.60 x 11 plf) for each full wall above. When calculating uplift loads for ends of headers/girders, multiply the tabulated unit uplift load by 1/ of the header/girder span (ft.). Cripple studs need only be attached per typical uplift requirements. For jack rafter uplift connections, use a roof span equal to twice the jack rafter length. The jack rafter length includes the overhang length and the jack span. Tabulated uplift loads for 0 psf design dead load are included for interpolation or use with actual roof dead loads. ENGINEERED DESIGN

14 ENGINEERED DESIGN Table.A Uplift Connection Loads from Wind Description: Uplift loads at the roof to wall connection. Procedure: Use Main Wind Force Resisting System (MWFRS) coefficients to calculate wind uplift forces. Sum moments to compute maximum uplift force at the roof to wall connection. Background: Per ASCE 7-10, worst case uplift loads occur at a 0 degree roof slope with wind perpendicular to the ridge and roof overhang uplift forces included. Roof/ceiling gravity loads are included to resist uplift forces. Example: Given - 150 mph, Exposure B, 33' MRH, 0 degree roof slope, 36' roof span, ' overhangs, 15 psf roof/ceiling dead load, 16" o.c. connection spacing. External pressure coefficients are taken from ASCE 7-10 Figure 8.4-1. Internal pressure coefficients are taken from ASCE 7-10 Table 6.11-1 and applied to the Windward Roof (WR) and Leeward Roof (LR). The pressure coefficient for the bottom surface of the Windward Overhang (WO) is computed using a gust factor (0.85) and a pressure coefficient (0.7) from sections ASCE 7-10 sections 6.9.1 and 8.4.3, respectively. The positive internal pressure coefficient was applied to the bottom surface of the Leeward Overhang (LO) to model background pressure. p roof = pressure on the roof portion p roof = q(gc pf - GC pi ), for each portion of the roof where: q = 1.15 psf (See Table C1.1) End Zone: GC pf = external pressure coefficients for MWFRS GC pi = +/- 0.18 internal pressure coefficient for enclosed buildings WO GC pf = -1.07, GC p = (0.85) (-0.7) = -0.60 WR GC pf = -1.07, GC pi = -0.18 LO GC pf = -0.69, GC pi = -0.18 LR GC pf = -0.69, GC pi = -0.18 Substituting: p LR = 1.15 (-0.69-0.18) = -18.4 psf p LO = 1.15 (-0.69-0.18) = -18.4 psf Since dead loads in this case are resisting uplift forces, they are multiplied by 0.6, per ASCE 7-10 section.4.1. Thus roof/ceiling dead loads are equal to: (15 psf) 0.6 = 9 psf Summing moments about the leeward roof-to-wall intersection, the uplift forces are calculated for a 1' wide section through the building. To parallel the notation above, the forces retain the WR, WO, etc., notation and are preceded by a V (for vertical) or H (for horizontal): VWO = -35.() = -70.4 lbs VWR = -6.4(36 / ) = -475. lbs VLR = -18.4(36 / ) = -331. lbs VLO = -18.4() = -36.8 lbs HWO = -35.()(tan(0 )) = -5.7 lbs HWR = -6.4(36 / )(tan(0 )) = -173.0 lbs HLR = -18.4(36 / )(tan(0 )) = -10.5 lbs HLO = -18.4()(tan(0 )) = -13.4 lbs The dead load of the roof, R, is also added: RWO = 9() = 18 lbs RWR = 9(18) = 16 lbs RLO = 9() = 18 lbs RLR = 9(18) = 16 lbs Summing moments about the leeward top of wall: ΣM L = 0 = [-70.4+18][1+36] + [-475.+16][9+18] + [-331.+16][9]- [-36.8+18][1] + [(-5.7) (0.364)] - [(-173.0)(3.76) ] + [(-10.5)(3.76)] - [(-13.4)(0.364)] - 36F W Solving for F W: F W = -36 plf Unit uplift connection load is: = 36 plf (WFCM Table.A) Required uplift capacity of connections spaced at 16" o.c. p WO = 1.15 (-1.07-0.60) = -35. psf = 36 plf (16 in./1in./ft) = 434 lbs = 36(1.33) (WFCM Table.A p WR = 1.15 (-1.07-0.18) = -6.4 psf Footnote 3)

COMMENTARY TO THE WOOD FRAME CONSTRUCTION MANUAL 15 Footnote 1: Tabulated loads are based on end zone pressures. Where the requirements of footnote 1 are met, tabulated loads may be decreased as follows: Given - 110 mph, Exposure B, 33' MRH, 0 degree roof slope, 1' roof span, ' overhangs, 0 psf roof/ceiling dead load, 1" o.c. End Zone uplift force is: 118 plf Interior Zone uplift force based on calculation similar to exterior zone is: 88 plf Reduction factor: = (88 plf) / (118 plf) = 0.75 ENGINEERED DESIGN Dead Load Wind Uplift Force Uplift Force Reaction (F W ) Leeward Wall

64 ENGINEERED DESIGN Table.B Ridge Connection Loads from Wind (Dead Load Assumptions: Roof Assembly DL = 10 psf) 700 yr. Wind Speed 3 second gust (mph) 110 115 10 130 140 150 160 170 180 195 1 3 4 5 Roof Pitch Roof Span (ft) Unit Connection Loads (plf) 1,,3,4,5 1 77 91 105 136 170 05 43 84 37 397 4 154 18 11 73 339 411 487 568 655 793 3:1 36 31 73 316 409 509 616 730 85 98 1190 48 308 364 4 545 678 81 974 1137 1309 1586 60 386 455 57 681 848 106 117 141 1636 1983 1 66 77 88 113 140 168 199 3 66 3 4 131 153 177 6 80 337 398 463 533 644 4:1 36 197 30 65 339 419 505 597 695 799 966 48 6 307 353 45 559 674 796 97 1065 188 60 38 384 44 565 699 84 995 1159 133 1610 1 51 60 69 88 109 13 156 18 09 53 4 10 119 138 177 19 64 31 364 418 506 5:1 36 153 179 07 65 38 396 468 545 67 758 48 04 39 76 353 437 58 64 77 836 1011 60 55 99 344 44 547 660 780 909 1045 164 1 48 55 63 81 99 119 141 164 188 7 4 95 111 17 16 199 39 8 37 376 453 6:1 36 143 166 190 4 98 358 43 491 564 680 48 190 1 54 33 398 478 564 655 751 907 60 38 77 317 404 497 597 704 818 939 1134 1 49 55 6 76 94 11 13 153 175 11 4 98 110 13 153 187 4 63 305 350 41 7:1 1:1 36 147 165 185 9 81 336 395 458 55 63 48 196 0 46 306 374 448 57 611 700 84 60 44 75 308 38 468 560 659 763 874 1053 Tabulated ridge connection loads shall be permitted to be multiplied by 0.70 for framing not located within 6 feet of corners for buildings less than 30 feet in width (W), or W/5 for buildings greater than 30 feet in width. Tabulated ridge connection loads assume a building located in Exposure B with a mean roof height of 33 feet. For buildings located in other exposures, the tabulated values shall be multiplied by the appropriate adjustment factor in Section.1.3.1. Tabulated ridge connection loads are specified in pounds per linear foot of ridge. To determine connection requirements, multiply the tabulated ridge connection load by the multiplier from the table below corresponding to the spacing of the connectors: Ridge Connection Spacing (in.) 1 16 19. 4 48 Multiplier 1.00 1.33 1.60.00 4.00 Tabulated ridge connection loads assume 0.6 of the roof assembly design dead load (0.6 x 10 psf). For buildings with roof slopes of less than 3:1, the roof framing members shall be attached to the ridge beam with connectors in accordance with Table.A.

16 ENGINEERED DESIGN Table.B Ridge Connection Loads From Wind Description: Procedure: Strap connection capacity required at ridge to resist separation due to wind uplift. Compute the wind uplift force using MWFRS coefficients. Sum moments to compute maximum horizontal tension force (T). T T where: p WR = pressure on windward roof p LR = pressure on leeward roof Since dead loads in this case are resisting uplift forces, they are multiplied by 0.6, per ASCE 7-10 section.4.1. Thus roof/ceiling dead loads are equal to: (10 psf) 0.6 = 6 psf Determining horizontal wind force at ridge: Background: Ridge straps restrain the ridge from separating under suction wind loads. Example: Given - 150 mph, Exposure B, 33' MRH, 7:1 roof pitch, 36' roof span, 10 psf roof dead load, 16" o.c. Wind pressures at ridge: where: p = qgc pf - qgc pi p = pressure on individual roof section GC pf = external pressure coefficient for that roof section. See Commentary Table.A q = 1.15 psf (See Table C1.1) p WR = 1.15[-1.07-0.18] = -6.4 psf Separating the roof system at the ridge and summing moments about the windward and leeward roof-to-wall intersection separately, the horizontal ridge forces needed to counterbalance the applied wind loads, designated F Rx (windward) and F Rx (leeward), can be determined. As in the commentary for Table.A, calculations are for a 1 foot wide section of roof and similar force notations; WR, WO, etc. are used. Subscripts V and H designate the direction of loads. WR V = -6.4(36 / ) = -475. lbs LR V = -15.0(36 / ) = -70.0 lbs WR H = -6.4(36 / )(7/1) = -77. lbs LR H = -15.0(36 / )(7/1) = -157.5 lbs Finally, the dead load R of each section of the roof is added. The dead loads act vertically: RWR V = 6.0(18) = 108 lbs RLR V = 6.0(18) = 108 lbs p LR = 1.15[-0.53-0.18] = -15.0 psf Dead Load Vertical Wind Component Horizontal Wind Component FRY FRX Leeward Wall

COMMENTARY TO THE WOOD FRAME CONSTRUCTION MANUAL 17 Summing moments about the windward top of wall: Required capacity of ridge connections spaced at 16" o.c. ΣM W = 0 = - [(-475.) + (108)][9] - [-77.][5.5] + 10.5F Rx + 18F Ry = 3304.8 +1455.3 + 10.5F Rx + 18F Ry Summing moments about the leeward top of wall: ΣM L = 0 = [(-70.0) + (108)][9] + [-157.5][5.5] - 10.5F Rx + 18F Ry = -1458.0 86.9-10.5F Rx + 18F Ry Setting 18F Ry (leeward) = 18F Ry (windward) ΣM W = 0 = 3304.8 +1455.3 + 10.5F Rx = -1458.0 86.9-10.5F Rx 1F Rx = 7045.0 = 336 plf (16 in./1in./ft) = 447 lbs = T(1.33) (WFCM Table.B Footnote 3) Footnote 1: For framing not located within W/5 or 6' of corners, wind pressures are reduced. Horizontal force at ridge: p WR = 1.15[-0.69-0.18] = -18.4 psf p LR = 1.15[-0.37-0.18] = -11.6 psf Using the reduced horizontal wind force and solving for F Rx : ENGINEERED DESIGN Solving for F Rx : F Rx = -336 plf Maximum horizontal tension force (T) per the figure of Table.B: T = 336 plf (WFCM Table.B) F Rx = 18 plf Dividing the reduced load by the tabulated load: = 18 / 336 = 0.65 WFCM Table.B specifies a slightly conservative multiplier of 0.70 to cover all cases.

WOOD FRAME CONSTRUCTION MANUAL 65 Table.C Rake Overhang Outlooker Uplift Connection Loads 700-yr. Wind Speed 3-second gust (mph) 110 115 10 130 140 150 160 170 180 195 Outlooker Spacing (in.) Uplift Connection Loads (lbs) 1,,3 1 187 05 3 6 304 349 397 448 50 589 16 50 73 98 349 405 465 59 597 669 786 4 375 410 446 54 607 697 793 896 4 1004 4 1178 4 1 Tabulated outlooker uplift connection loads assume a building located in Exposure B with a mean roof height of 33 feet. For buildings located in other exposures, or with mean roof heights less than 33 feet, the tabulated values shall be multiplied by the appropriate adjustment factor in Section.1.3.1. Tabulated outlooker uplift connection loads are based on foot overhangs. For overhangs less than feet, tabulated values shall be permitted to be multiplied by [(' + OH) / 4'] (OH measured in feet). 3 For overhangs located in Zone per the figures of Table.4, tabulated uplift loads shall be permitted to be multiplied by 0.65. 4 Outlooker overhang length shall be limited to 0 inches. See footnote to calculate reduced uplift connection load. ENGINEERED DESIGN 4 o.c. Nail Spacing L Connec on per Sec on...1 &..6.5 4 Perimeter Zone panel field nailing 4 Perimeter Zone panel edge nailing Lesser of L/ or Required Blocking Minimum x4 Outlooker Gable Endwall

18 ENGINEERED DESIGN Table.C Rake Overhang Outlooker Uplift Connection Loads Description: Uplift loads at the connection of the rake overhang outlooker to endwall or rake truss. Procedure: Calculate wind pressures based on C&C pressure coefficients assuming Zone 3 and Zone 3 Overhang wind loads per the Figure of Table.4. Sum moments about the first interior truss to calculate the uplift connection load. Background: Outlooker connection loads are based on Table.4 suction pressures. Example: Given - 150 mph, Exposure B, 4" o.c. outlooker spacing, 4" truss spacing, ' overhang. For Zone 3 Roof Overhangs the suction pressure is: From WFCM Table.4: 78.3 psf For Zone 3 Roof the suction pressure is: From WFCM Table.4: 63.0 psf Summing moments about the first interior truss, the uplift force at the connector: Thus, where Zone occurs, tabulated loads may be multiplied by the following factor: U zone /U zone 3 U zone /U zone 3 Required Blocking = (419 lbs) /(697 lbs) = 0.60 (a conservative multiplier of 0.65 is specified in Table. Footnote 3) Wind Uplift Forces Uplift Connector Gable Endwall First Interior Truss or Rafter Outlooker Footnote 4: For the footnoted cases in Table.C, the outlooker overhang length, L overhang, is limited to 0 inches based on the bending capacity of the outlooker. w = 13.3 psf ΣM = 0 = (78.3/1)(36 in.)(4 in.) + (63.03/1)(4 in.) (1 in.) - (U)(4 in. - 3.5 in.) U = [(78.6/1)(36 in.)(4 in.) + (63.03/1)(4 in.)(1 in.)]/(4 in. 3.5 in.) U = 349 lbs/ft Required capacity of connections spaced at 4" o.c. U = 349 lbs/ft (4 in./1 in./ft) U = 697 lbs (WFCM Table.C) Footnote 3: Tabulated loads may be reduced when they occur in Zone per the Figure of Table.4. The required capacity for a connector in Zone with Zone overhang wind loads for the overhanging section is: U zone = 419 lbs L overhang 1/ 3.5 M < F b S x L The bending moment, M, due to the uplift forces on the portion of the cantilevered outlooker is: M = (wl )/ = (13.3/1)(L )/ = 5.51 (L ) in.-lbs/ft

COMMENTARY TO THE WOOD FRAME CONSTRUCTION MANUAL 19 where: M Req. < F b ' S x w = 13.3 psf (WFCM Table.4 Zone 3 Overhang @ 195 mph) L = L overhang + 1/ in. (sheathing thickness) + 3.5 in. (width of stud) L overhang = L - 4 in. F b ' S x for a No., x4 Southern Pine Outlooker is: F b ' S x = F b C D C F C r S x = (1,100 psi)(1.6)(1.0)(1.15)(3.065) = 6,199 in.-lbs (Note: In the NDS Supplement, bending design values for Southern Pine are already size-adjusted, so the size factor, C F, is equal to 1.0.) For outlookers spaced at 4" o.c. (5.51)(L ) in.-lbs/ft (ft) 6,199 in.-lbs L 3.7 in. Therefore L overhang 3.7-4 in. = 19.7 in. ~0 in. WFCM Table.C limits outlooker overhang lengths to 0" for 4" outlooker spacing and the 195 mph, 180 mph, and 175 mph (700 yr, 3-second gust) Exposure B wind load cases. NOTE: WFCM Table 3.4C provides additional outlooker overhang limits for Exposure C wind load cases. ENGINEERED DESIGN

WOOD FRAME CONSTRUCTION MANUAL 67 Table.4 Roof and Wall Sheathing Suction Loads (For Sheathing and Sheathing Attachment) 700 yr. Wind Speed 3 second gust (mph) Sheathing Location 1 110 115 10 130 140 150 160 170 180 195 Zone 1 13.4 14.7 16.0 18.7 1.7 5.0 8.4 3.1 35.9 4. Zone.5 4.6 6.8 31.5 36.5 41.9 47.6 53.8 60.3 70.8 Zone 3 33.9 37.0 40.3 47.3 54.9 63.0 71.7 81.0 90.8 106.5 Zone 3 Overhang 4.1 46.0 50.1 58.8 68. 78.3 89.0 100.5 11.7 13.3 Zone 4 14.6 15.9 17.3 0.3 3.6 7.1 30.8 34.8 39.0 45.8 Zone 5 18.0 19.6 1.4 5.1 9.1 33.4 38.0 4.9 48.1 56.5 The dimension, a, is measured as 10% of the minimum building dimension, but not less than 3 feet. Tabulated framing loads assume a building located in Exposure B with a mean roof height of 33 feet. For buildings located in other exposures, the tabulated values shall be multiplied by the appropriate adjustment factor in Section.1.3.1. 1 Dual Slope Roof Suction Pressure (psf) ENGINEERED DESIGN

ENGINEERED DESIGN Table.4 Roof and Wall Sheathing Suction Loads Description: Procedure: Suction pressure on roof sheathing. Calculate wind pressures based on C&C pressure coefficients. Background: Roof sheathing suction loads are tabulated for dual-slope roofs based on ASCE 7-10 Figures 30.4-A, B, and C. The roof slope creating the greatest suction loads for slopes between 7 o and 45 o are tabulated. Wall sheathing suction loads are tabulated based on ASCE 7-10 Figure 30.4-1. Example: 150 mph, Exposure B, 33' MRH Zone 3 Overhang: GC p = -.5-1.([log(A/100)] / [log(10/100)]) = -3.7 For all Zones GC pi = +/- 0.18 Calculate roof pressures: (Negative pressures denote suction) Zone 1: p = 1.15 (-1.0-0.18) = -5.0 psf (WFCM Table.4) where: p = q(gc p - GC pi ) Zone : p = 1.15(-1.8-0.18) = -41.9 psf (WFCM p = pressure on the roof/wall Table.4) q = 1.15 psf (See Table C1.1) Zone Overhang: p = 1.15(-.) = -46.5 psf GC p = external pressure coefficient for individual roof/wall areas GC pi = +/- 0.18 internal pressure coefficient for enclosed buildings ASCE 7-10 states that for cladding and fasteners, the effective wind area shall not be greater than the tributary area for an individual fastener. Maximum loads occur for effective wind areas 10 ft or less. Sheathing suction loads are therefore based on an effective wind area of 10 ft for all roof and wall zones. From ASCE 7-10 Figures 30.4-A, B, and C: Zone 1: Zone : GC p = -0.9-0.1([log(A/100)] / [log(10/100)]) = -1.0 GC p = -1.1-0.7([log(A/100)] / [log(10/100)]) = -1.8 Zone Overhang: Zone 3: GC p = -. GC p = -1.7-1.1([log(A/100)] / [log(10/100)]) = -.8 Zone 3: p = 1.15(-.8-0.18) = -63.0 psf Zone 3 Overhang: (WFCM Table.4) p = 1.15(-3.7) = -78.3 psf (WFCM Table.4) From ASCE 7-10 Figure 30.4-1: Zone 5: Zone 4: GC p = -0.8-0.6[(log(A/100)) / (log(10/100))] = -1.4 GC p = -0.8-0.3[(log(A/100)) / (log(10/100))] = -1.1 For all Zones GC pi = +/- 0.18 Calculate wall pressures: (Negative pressures denote suction) Zone 4: Zone 5: p = 1.15(-1.1-0.18) = -7.1 psf p = 1.15(-1.4-0.18) = -33.4 psf (WFCM Table.4) (WFCM Table.4)

68 ENGINEERED DESIGN Table.5A Lateral Diaphragm Loads from Wind - Perpendicular to Ridge (For Calculating In-Plane Shear in Roof and Floor Diaphragm) Roof / Ceiling Diaphragm Shear Wall Floor Diaphragm w roof w floor w floor w floor B L 700 yr. Wind Speed 110 115 10 130 140 150 160 170 180 195 3 second gust (mph) Roof Pitch Roof Span (ft) Unit Lateral Loads for Roof Diaphragm, w roof, (plf) 1,3,4,5 0:1 1:1 4 60 60 60 60 6 7 8 94 106 118 139 4 6 6 65 76 88 101 115 130 146 17 :1 3:1 36 70 70 70 76 88 101 115 130 146 17 48 77 77 77 77 88 101 115 130 146 17 60 84 84 84 84 88 101 115 130 146 17 4 67 67 71 83 97 111 16 14 160 187 4:1 36 77 77 77 83 97 111 16 14 160 187 48 86 86 86 86 97 111 16 14 160 187 60 96 96 96 96 97 111 16 14 160 187 4 7 7 7 84 97 11 17 143 161 189 5:1 36 84 84 84 84 95 110 15 141 158 185 48 96 96 96 96 96 110 15 141 158 185 60 108 108 108 108 108 110 15 141 158 185 4 83 90 98 115 134 154 175 197 1 60 6:1 36 94 10 11 131 15 174 198 4 51 95 48 106 116 16 148 17 197 4 53 84 333 60 10 19 141 165 191 0 50 8 316 371 4 110 11 131 154 179 05 34 64 96 347 7:1 36 136 149 16 190 0 53 87 35 364 47 48 163 178 194 7 63 30 344 388 435 511 60 189 07 5 65 307 35 401 45 507 595 4 118 19 141 165 191 0 50 8 316 371 8:1 36 147 161 175 06 39 74 31 35 395 463 48 178 194 1 48 88 331 376 45 476 559 60 08 8 48 91 338 388 441 498 558 655 4 16 138 150 176 04 34 66 301 337 396 9:1 36 159 174 189 57 95 336 379 45 499 48 193 11 30 70 313 359 409 461 517 607 60 8 49 71 318 369 43 48 544 609 715 4 134 146 159 187 16 49 83 319 358 40 10:1 36 170 186 03 38 76 317 360 407 456 535 48 08 8 48 91 338 388 441 498 558 655 60 47 70 94 345 400 459 5 589 661 775 4 141 155 168 197 9 63 99 338 379 444 11:1 36 18 199 16 54 94 338 385 434 487 571 48 4 45 66 313 36 416 473 534 599 703 60 66 91 316 371 431 494 56 635 71 835 4 149 163 177 08 4 77 315 356 399 469 1:1 36 193 11 30 70 313 359 409 461 517 607 48 39 61 85 334 387 445 506 571 640 751 60 85 311 339 398 46 530 603 681 763 895 Unit Lateral Loads for Floor Diaphragm, w floor, (plf) 1,,3,5 135 148 161 189 19 51 86 33 36 45 See footnotes 1-5.

COMMENTARY TO THE WOOD FRAME CONSTRUCTION MANUAL 3 Table.5A Lateral Diaphragm Loads from Wind - Perpendicular to Ridge (Roof and Floor Shear) Description: For calculating lateral loads in roof and floor diaphragms from wind forces acting perpendicular to the roof ridge. Procedure: Compute wall and roof wind pressures. Collect forces into diaphragms. Background: Lateral loads are based on MWFRS and are a function of roof slope. For loads into floor diaphragms, the MWFRS coefficients are based on a worst case 0 degree roof slope. Minimum 10 psf (ASD) wall pressure and minimum 5 psf (ASD) roof pressure specified by ASCE 7-10 Section 8.4.4 are checked. Example: Given - 150 mph, Exposure B, 33' MRH, 6:1 roof slope, 4' roof span, 10' wall height. Since these pressures act in the same direction, they will sum to 19.9 psf at the interior zone and 6.7 psf at the end zone. Calculate the average pressure on the wall assuming a building length (parallel to ridge), L, equal to the roof span (4 ft): where: p = [19.9(L-X) + 6.7(X)] / L = [19.9 psf (18 ft) + 6.7 psf (6 ft)] / 4 = 1.59 psf L = Building Length (parallel to ridge) X = End Zone Length Calculate the roof pressures for a 6:1 roof pitch: ENGINEERED DESIGN Floor Diaphragm Roof Diaphragm B L w roof w floor w floor w floor Interior Zone End Zone Windward Leeward Windward Leeward GC pf -0.10-0.45-0.19-0.58 GC pi 0.18 0.18 0.18 0.18 p (psf) -5.9-13.3-7.9-16.3 Since these pressures act in opposite directions, they will sum to 7.4 psf at the interior zone and 8.4 psf at the end zone. Calculate the average pressure on the roof: Calculate wind forces in roof and floor diaphragms: p = q(gc pf - GC pi ) where: p = pressure on the roof/walls where: p = [7.4(L-X) + 8.4(X)] / L = [7.4(18 ft) + 8.4(6 ft)] / 4 = 7.65 psf W = Building Length (parallel to ridge) X = End Zone Length q = 1.15 psf (See Table C1.1) Calculate wall pressures: Interior Zone End Zone Windward Leeward Windward Leeward GC pf 0.55-0.39 0.73-0.53 GC pi 0.18 0.18 0.18 0.18 p (psf) 7.8-1.1 11.6-15.1 Calculate the lateral load on the roof diaphragm: The roof diaphragm will take load from half the wall below and load directly applied to the vertical projection of the roof diaphragm. w roof = 1.59(10/ ft) + 7.65[(6/1)(4/) ft] w roof = 1.59(5 ft) + 7.65(6 ft) = 154 plf (WFCM Table.5A)

4 ENGINEERED DESIGN Calculate average pressure on the wall given the maximum MWFRS coefficients occur at a 0 degree roof slope per ASCE 7-10. Interior Zone End Zone Windward Leeward Windward Leeward GC pf 0.53-0.43 0.80-0.64 GC pi 0.18 0.18 0.18 0.18 p (psf) 7.4-1.9 13.0-17.3 p = [0.3(18 ft) + 30.3(6 ft) +]/4 =.8 psf Summing the wall pressure for a 10' high wall and adding an extra 1' to account for the depth of the floor joists, calculate the lateral load on the floor diaphragm: w floor =.8(11) = 51 plf (WFCM Table.5A) Since these pressures act in the same direction, they will sum to 0.3 psf at the interior zone and 30.3 psf at the end zone.

WOOD FRAME CONSTRUCTION MANUAL 69 Table.5B Lateral Diaphragm Loads from Wind - Parallel to Ridge (For Calculating In-Plane Shear in Roof and Floor Diaphragm) w roof Roof / Ceiling Diaphragm Shear Wall w floor w floor w floor B L Floor Diaphragm ENGINEERED DESIGN 700 yr. Wind Speed 3 second gust (mph) Roof Pitch 0:1 1:1 :1 3:1 4:1 5:1 6:1 7:1 8:1 9:1 10:1 11:1 1:1 See footnotes 1-5. Roof Span (ft) 110 115 10 130 140 150 160 170 180 195 Unit Lateral Loads for Roof Diaphragm, w roofll, (plf) 1,3,4,5 4 60 60 60 61 7 83 96 109 13 138 16 4 6 6 65 76 88 101 115 130 145 170 36 70 70 71 84 97 111 16 143 160 188 48 77 77 79 9 107 13 140 158 177 07 60 84 84 86 101 117 134 153 17 193 7 4 67 67 70 8 95 109 14 140 156 184 36 77 77 79 9 107 13 140 158 177 07 48 86 86 88 104 10 138 157 177 199 33 60 96 96 98 115 134 153 174 197 1 59 4 7 7 74 87 101 116 13 150 168 197 36 84 84 86 101 117 134 153 17 193 7 48 96 96 98 115 134 153 174 197 1 59 60 108 108 110 130 150 173 196 48 9 4 77 77 79 93 108 14 141 159 179 10 36 91 91 93 109 17 146 166 187 10 46 48 106 106 108 17 147 169 19 17 43 85 60 10 10 13 144 167 19 18 46 76 34 4 8 8 84 99 115 13 150 169 190 3 36 98 98 101 118 137 157 179 0 6 66 48 115 115 118 138 160 184 09 36 65 311 60 13 13 135 158 184 11 40 71 304 356 4 86 86 89 105 1 140 159 179 01 36 36 106 106 108 17 147 169 19 17 43 85 48 15 15 18 150 174 199 7 56 87 337 60 144 144 147 173 00 30 6 95 331 389 4 91 91 94 111 18 147 168 189 1 49 36 113 113 115 135 157 180 05 31 59 305 48 134 134 137 161 187 15 44 76 309 363 60 156 156 159 187 17 49 84 30 359 41 4 96 96 99 117 135 155 177 199 3 6 36 10 10 13 144 167 19 18 46 76 34 48 144 144 147 173 00 30 6 95 331 389 60 168 168 17 0 34 68 305 345 386 454 4 101 101 104 1 14 163 185 09 35 75 36 17 17 130 153 177 03 31 61 93 343 48 154 154 157 184 14 45 79 315 353 415 60 180 180 184 16 50 88 37 369 414 486 4 106 106 109 18 149 171 194 19 46 89 36 134 134 137 161 187 15 44 76 309 363 48 163 163 167 196 7 61 97 335 375 441 60 19 19 196 30 67 307 349 394 44 518 Unit Lateral Loads for Floor Diaphragm, w floorii, (plf) 1,,3,5 9 100 109 18 149 171 194 19 46 89

COMMENTARY TO THE WOOD FRAME CONSTRUCTION MANUAL 5 Table.5B Lateral Diaphragm Loads from Wind - Parallel to Ridge (Roof and Floor Shear) Description: For calculating lateral loads in roof and floor diaphragms from wind forces acting parallel to the roof ridge. Procedure: Compute wall and roof wind pressures. Collect forces into diaphragms. Background: Lateral loads are based on MWFRS. For wind loads parallel to the ridge, MW- FRS coefficients are not dependent on roof slope. Lateral forces into the roof diaphragm shall include the contribution from the triangular portion of the gable end wall in addition to the tributary portion of the wall below. Minimum 10 psf (ASD) wall pressure specified by ASCE 7-10 Section 8.4.4 is checked. Example: Given - 150 mph, Exposure B, 33' MRH, 7:1 roof pitch, 4' roof span. Interior Zone End Zone Windward Leeward Windward Leeward GC pf 0.40-0.9 0.61-0.43 GC pi 0.18 0.18 0.18 0.18 p (psf) 4.7-9.9 9.1-1.9 Since these forces act in the same direction, they will sum to 14.6 psf at the interior zone and.0 psf at the end zone. Calculate the average pressure on the gable end wall. where: p = [14.6(B-X) +.0(X)] / B = [14.6(1 ft) +.0(3 ft)] / (4 ft.) = 15.53 psf B = Building Width (perpendicular to the ridge) X = End Zone Length ENGINEERED DESIGN w roof w floor Roof Diaphragm Floor Diaphragm Calculate the lateral load on the roof diaphragm: w roof = [p wall (A gable )/B] + [p wall (H wall /)] = [15.53(½)(4 ft)(7 ft)] / 4 + [15.53(10 ft/)] = 13 plf (WFCM Table.5B) w floor w floor B L Note: The calculation for w roof, assumes there is no attic/floor ceiling diaphragm. If an attic floor/ ceiling diaphragm is used, the lateral load on the roof diaphragm, w roof, can be reduced by subtracting the lateral load acting on the attic floor/ceiling diaphragm per Table.5C. Calculate the lateral load on the floor diaphragm: Calculate forces in roof and floor diaphragms: p = q(gc pf - GC pi ) where: p = pressure on the wall Summing this pressure for a 10' high wall and adding an extra 1' to account for the depth of the floor joists, calculate the lateral load on the floor diaphragm: w floor = 15.53(11) = 171 plf (WFCM Table.5B) q = 1.15 psf (See Table C1.1) Calculate wall pressures:

70 ENGINEERED DESIGN Footnotes to Tables.5A and.5b 1 The total shear load equals the tabulated unit lateral load multiplied by the building length perpendicular to the wind direction. Tabulated unit lateral loads are based on 10 foot wall heights and a 1 foot floor depth. For other wall heights, H, tabulated values for floor diaphragms shall be permitted to be used when multiplied by (H+1)/11. 3 Tabulated unit lateral loads assume a building located in Exposure B with a mean roof height of 33 feet. For buildings located in other exposures, the tabulated values shall be multiplied by the appropriate adjustment factor in Section.1.3.1. 4 Hip roof systems shall be designed using Table.5A for both orthogonal directions. 5 Shear capacity requirements for roof diaphragms, shear walls, and floor diaphragms shall be calculated as follows: Calculating Total Shear Capacity Requirements V roof, V floor Calculating Diaphragm Unit Shear Capacity Requirements v roof, v floor Calculating Total Shear Wall Shear Capacity Requirements V wall Wind Perpendicular to Ridge ( w from Table.5A) V w ( L) roof roof (lbs) Vfloor () i wfloor() i ( L) Wind Parallel to Ridge ( w from Table.5B) V ( ) roof wroof B V ( ) floor ( i) wfloor ( i) B Wind Perpendicular to Ridge Vroof vroof ( B) V floor( i) v floor( i) ( B) (plf) v v Wind Parallel to Ridge roof floor ( i) Vroof ( L) V floor ( i ( L) ) (plf) Wind Perpendicular to Ridge Wind Parallel to Ridge Shear Wall Bracing Roof & Ceiling V V V wall Vroof wall roof V V Shear Wall Bracing Roof/Ceiling & 1 Floor V wall V V roof floor (1) wall V V roof floor(1) Shear Wall Bracing Roof/Ceiling & Floors V wall V V V roof floor (1) floor () wall V V V roof floor(1) floor()

WOOD FRAME CONSTRUCTION MANUAL 71 Table.5C Lateral Diaphragm Loads from Wind - Parallel to Ridge (For Attic Floor or Ceiling Diaphragm When Bracing Gable Endwall) Tribut ary Area of Ceiling Diaphragm w 700 yr. Wind Speed 3 second gust (mph) Roof Pitch 0:1 1:1 :1 3:1 4:1 5:1 6:1 7:1 8:1 9:1 a c floor / ceiling 10:1 11:1 1:1 A c Floor / Ceiling Diaphragm Roof Span (ft) 110 115 10 130 140 150 160 170 180 195 Unit Lateral Loads for Attic Floor/Ceiling Diaphragm, w attic floor/ceiling (plf) 1,,3,4,5,6,7,8 4 60 54 54 55 65 75 86 98 111 14 146 4 55 55 57 67 78 89 10 115 19 151 36 59 59 60 71 8 94 107 11 135 159 48 6 6 64 75 87 100 113 18 144 168 60 66 66 67 79 9 105 10 135 15 178 4 58 58 60 70 81 93 106 10 134 157 36 6 6 64 75 87 100 113 18 144 168 48 67 67 69 81 94 107 1 138 155 181 60 7 7 74 86 100 115 131 148 166 194 4 60 60 6 73 84 97 110 15 140 164 36 66 66 67 79 9 105 10 135 15 178 48 7 7 74 86 100 115 131 148 166 194 60 78 78 80 94 109 15 14 160 179 11 4 6 6 65 76 88 101 115 130 145 170 36 70 70 71 84 97 111 16 143 160 188 48 77 77 79 9 107 13 140 158 177 07 60 84 84 86 101 117 134 153 17 193 7 4 65 65 67 79 91 105 119 135 151 177 36 73 73 75 88 10 117 133 150 168 198 48 8 8 83 98 114 130 148 167 188 0 60 90 90 9 108 15 144 164 185 07 43 4 67 67 70 8 95 109 14 140 156 184 36 77 77 79 9 107 13 140 158 177 07 48 86 86 88 104 10 138 157 177 199 33 60 96 96 98 115 134 153 174 197 1 59 4 70 70 7 85 98 113 18 145 16 190 36 80 80 8 96 11 18 146 165 185 17 48 91 91 93 109 17 146 166 187 10 46 60 10 10 104 1 14 163 185 09 35 75 4 7 7 74 87 101 116 13 150 168 197 36 84 84 86 101 117 134 153 17 193 7 48 96 96 98 115 134 153 174 197 1 59 60 108 108 110 130 150 173 196 48 9 4 74 74 77 90 105 10 137 154 173 03 36 88 88 90 105 1 140 159 180 01 36 48 101 101 103 11 140 161 183 07 3 7 60 114 114 117 137 159 18 07 34 6 308 4 77 77 79 93 108 14 141 159 179 10 36 91 91 93 109 17 146 166 187 10 46 48 106 106 108 17 147 169 19 17 43 85 60 10 10 13 144 167 19 18 46 76 34 W IND ENGINEERED DESIGN See footnotes 1-8.

7 ENGINEERED DESIGN Footnotes to Table.5C 1 The total shear load equals the tabulated unit lateral load multiplied by the endwall length. Tabulated unit lateral loads are based on 10 foot wall heights. 3 Tabulated unit lateral loads assume the attic floor/ceiling diaphragm is continuous between endwalls. When the diaphragm only resists loads from one endwall, the tabulated unit lateral load shall be multiplied by 0.84. 4 Tabulated unit lateral loads assume a building located in Exposure B with a mean roof height of 33 feet. For buildings located in other exposures, the tabulated values shall be multiplied by the appropriate adjustment factor in Section.1.3.1. 5 Attic floor or ceiling diaphragms shall not be used to brace gable endwalls used with cathedral ceilings. 6 Attic floor or ceiling diaphragms are not required for hip roof systems. 7 When a ceiling diaphragm is used to brace the gable endwalls, the unit lateral loads on the roof diaphragm, when the wind is parallel to the ridge, need not exceed the tabulated roof lateral load (from Table.5B) minus the ceiling lateral load (from Table.5C). 8 Shear capacity requirements for attic floor or ceiling diaphragms shall be calculated as follows: Calculating Total Shear Capacity Requirements V roof, V attic floor/ceiling (lbs) Calculating Diaphragm Unit Shear Capacity Requirements v roof, v attic floor/ceiling (plf) Vattic floor/ ceiling wattic floor/ ceiling ( B) V roof Vroof ( fromtable.5b) Vattic floor / ceiling v attic floor / ceiling v roof V attic floor / ceiling Vroof ( L) ( L)

6 ENGINEERED DESIGN Table.5C Lateral Diaphragm Loads from Wind - Parallel to Ridge Description: For calculating lateral loads in attic floor or ceiling diaphragms when bracing gable end walls. Procedure: Compute loads on end walls tributary to the attic floor/ceiling diaphragm. Background: Lateral loads are based on MWFRS. For wind loads parallel to the ridge, MW- FRS coefficients are not dependent on roof slope. Lateral forces into the attic floor/ceiling diaphragm shall include the tributary contribution from the triangular portion of the gable end wall in addition to the tributary portion of the wall below. Minimum 10 psf (ASD) wall pressure specified by ASCE 7-10 Section 8.4.4 is checked. Example: Given - 150 mph, Exposure B, 33' MRH, 6:1 roof slope, 4' building width (perpendicular to ridge). Tribut ary Area of Ceiling Diaphragm B A gable = (½) [½ (6 ft)(4 ft)] = 36 ft A wall = (5 ft)(4 ft) = 10 ft A total = 36+10 = 156 ft w W IND a c floor / ceiling Calculate the wall pressure: p = 15.53 psf A c Floor / Ceiling Diaphragm (See Commentary for Table.5B) Calculate the lateral load on the attic floor/ceiling diaphragm: When an attic floor or ceiling diaphragm is used to brace a gable end wall for wind, the loaded area equals half the area of the gable above plus half the wall below. The areas are calculated as: w attic floor/ceiling = [p wall (A total )] / W = [15.53 psf (156 ft )] / 4 ft = 101 plf (WFCM Table.5C) Footnote 3: Where the diaphragm resists loads from only one end wall the average pressure on the wall is a function of either the loads on the windward or leeward wall. For a gable end wall, the worst case MWFRS loads occur on the windward wall. Tabulated loads may be conservatively reduced by taking the ratio of the windward load for a single end wall to the windward and leeward wall loads. The table below shows the external MWFRS pressure coefficients and internal pressure coefficients for windward and leeward end walls. It can be shown that the most conservative case (least amount of reduction) when the attic/ceiling diaphragm resists loads from only one end wall, is to use a negative internal pressure for the interior zone as follows:

COMMENTARY TO THE WOOD FRAME CONSTRUCTION MANUAL 7 Interior Zone End Zone Windward Leeward Windward Leeward GC pf 0.40-0.9 0.61-0.43 GC pi ±0.18 ±0.18 ±0.18 ±0.18 positive internal pressure (psf) negative internal pressure (psf) 4.7-9.9 9.1-1.9 1.3 -.3 16.7-5. Reduction Factor = 1.3 / [1.3 - (-.3)] = 0.84 Footnote 7: The lateral load on the roof diaphragm from Table.5B may be reduced as follows using this example: w roof (with attic floor/ceiling diaphragm) = w roof (without attic floor/ceiling diaphragm) w attic floor/ceiling = 14 101 = 3 plf. ENGINEERED DESIGN

WOOD FRAME CONSTRUCTION MANUAL 81 Table.9A Exterior Wall Stud Bending Stresses from Wind Loads (Cont.) 700 yr. Wind Speed 3 second gust (mph) Stud Size Wall Height 8 ft 10 ft 1 ft 14 ft 16 ft 18 ft 0 ft 1 3 Stud Spacing 150 160 170 x4 x6 x8 x4 x6 x8 x4 x6 x8 x4 x6 x8 x4 x6 x8 Induced f b (psi) 1,,3 1 in. 903 366 11 108 416 40 1160 470 70 1301 57 303 157 618 356 16 in. 105 488 81 1371 555 319 1547 67 361 1735 70 404 036 84 474 4 in. 1807 73 41 056 833 479 31 940 541 60 1054 606 3054 137 71 1 in. 1365 553 318 1553 69 36 1754 710 409 1966 796 458 307 934 538 16 in. 180 737 44 071 839 483 338 947 545 61 106 611 3077 146 717 4 in. 731 1106 636 3107 158 74 3507 140 817 393 159 916 4615 1869 1076 1 in. 1906 77 444 168 878 505 448 991 570 744 1111 640 30 1304 751 16 in. 541 109 59 891 1171 674 363 13 761 3659 148 853 494 1739 1001 4 in. 3811 1543 888 4336 1756 1011 4895 198 1141 5488 179 608 1501 1 in. 519 100 587 866 1161 668 336 1310 754 368 1469 845 458 174 99 16 in. 3359 1360 783 38 1548 891 4314 1747 1006 4837 1959 117 5677 99 133 4 in. 5039 040 1174 5733 3 1336 61 1508 938 1691 3448 1985 1 in. 303 197 746 3644 1476 849 4113 1666 959 461 1868 1075 541 19 161 16 in. 470 179 995 4858 1967 113 5485 1 178 490 1433 9 168 4 in. 594 1493 951 1698 333 1917 3735 150 4383 53 1 in. 395 1600 91 4496 181 1048 5076 056 1183 5691 304 136 705 1556 16 in. 569 134 18 5995 48 1397 741 1577 3073 1768 3606 075 4 in. 301 184 364 096 4111 366 4609 65 5409 3113 1 in. 4764 199 1110 540 195 163 478 146 778 1599 360 1876 16 in. 57 1480 97 1684 3304 1901 3704 13 4347 50 4 in. 3859 1 4390 57 4956 85 5556 3198 3753 Tabulated bending stresses assume a building located in Exposure B with a mean roof height of 33 feet. For buildings located in other exposures, the tabulated values shall be multiplied by the appropriate adjustment factor in Section.1.3.1. Tabulated bending stresses shall be permitted to be multiplied by 0.9 for framing not located within 3 feet of corners for buildings less than 30 feet in width (W), or within W/10 of corners for buildings greater than 30 feet in width. The tabulated bending stress (f b ) shall be less than or equal to the allowable bending design value (F b '). 180 195 ENGINEERED DESIGN

COMMENTARY TO THE WOOD FRAME CONSTRUCTION MANUAL 33 Table.9A Exterior Wall Stud Bending Stresses from Wind Loads Description: Procedure: Bending stress in wall studs due to wind load. Compute wind pressures using C&C coefficients and calculate stud requirements. Background: As in Table.4, peak suction forces are very high. Defining the effective wind area and the tributary area of the wall stud is key to computing the design suction. Stud span equals the wall height minus the thickness of the top and bottom plates. For a nominal 8' wall, the height is: 97 1/8" - 4.5" = 9 3/8". Two cases have been checked in these tables. For C&C wind pressures, the bending stresses are computed independent of axial stresses. In addition, the case in which bending stresses from MWFRS pressures act in combination with axial stresses from wind and gravity loads must be analyzed. For buildings limited to the conditions in this Manual, the C&C loads control the stud design. Example: Given - 150 mph, Exposure B, 33' MRH, 10' wall height, x4 studs, 16" o.c. stud spacing. Calculations from Table.10 for exterior wall induced moments from wind loads showed the applied bending moment for this case to be 464.6 ft-lbs. Substituting this bending moment into a bending stress calculation: f b = M (tabulated) /S = 464.6 (1)/3.065 = 1,80 psi f b (Tabulated) = 1,80 psi (WFCM Table.9A) Footnote : See Commentary Table.1 for calculation of footnotes. ENGINEERED DESIGN

WOOD FRAME CONSTRUCTION MANUAL 85 Table.10 Exterior Wall Induced Moments from Wind Loads 700 yr. Wind Speed 3 second gust (mph) Wall Height 8 ft 10 ft 1 ft 14 ft 16 ft 18 ft 0 ft 1 Stud Spacing 110 115 10 130 140 150 160 170 180 195 Induced Moment (ft lbs) 1, 1 in. 14 136 148 173 01 31 6 96 33 390 16 in. 165 181 197 31 68 307 350 395 443 50 4 in. 48 71 95 346 40 461 55 59 664 779 1 in. 187 05 3 6 304 348 396 448 50 589 16 in. 50 73 97 349 405 465 59 597 669 785 4 in. 375 410 446 53 607 697 793 895 1004 1178 1 in. 6 86 311 365 44 486 553 65 700 8 16 in. 349 381 415 487 565 648 738 833 934 1096 4 in. 53 57 6 731 847 973 1107 149 1401 1644 1 in. 346 378 411 483 560 643 73 86 96 1087 16 in. 461 504 549 644 747 857 975 1101 134 1449 4 in. 69 756 83 966 110 186 1463 165 185 173 1 in. 440 480 53 614 71 817 930 1050 1177 1381 16 in. 586 641 697 819 949 1090 140 1400 1569 184 4 in. 879 961 1046 18 144 1635 1860 100 354 763 1 in. 54 593 645 758 879 1009 1147 195 145 1704 16 in. 73 790 861 1010 1171 1345 1530 177 1936 73 4 in. 1085 1186 191 1515 1757 017 95 591 905 3409 1 in. 654 715 778 913 1059 116 1383 156 1751 055 16 in. 87 953 1038 118 141 161 1844 08 334 740 4 in. 1308 149 1556 186 118 43 767 313 350 4110 Tabulated induced moments assume a building located in Exposure B with a mean roof height of 33 feet. For buildings located in other exposures, the tabulated values shall be multiplied by the appropriate adjustment factor in Section.1.3.1. Tabulated induced moments shall be permitted to be multiplied by 0.9 for framing not located within 3 feet of corners for buildings less than 30 feet in width (W), or within W/10 of corners for buildings greater than 30 feet in width. ENGINEERED DESIGN

36 ENGINEERED DESIGN Table.10 Exterior Wall Induced Moments From Wind Loads Description: Applied moment on wall due to wind loads. Procedure: Calculate the applied moment based on C&C wind pressures. Background: Applied suction force is dependent on tributary areas. Example: Given - 150 mph, Exposure B, 33' MRH, 10' wall height, 16" o.c. stud spacing. Substituting this uniform load, w, into a bending calculation for a simply supported member: M = wl 8 ( 39 48) 10 3.. ( 375 ) = 1 8 = 466 ft lbs p max = 9.61 psf (See Commentary to Table.1) w = p max (16 in./1in./ft) = 39.48 plf M (Tabulated) = 466 ft-lbs (A value of 465ft-lbs is shown in WFCM Table.10 difference due to rounding in calculation of p max )

96 ENGINEERED DESIGN Table.14A Rafter Spans for 0 psf Live Load L/D LL = 180 L/D LL = 40 L/D LL = 360 Attached Ceiling x4 x6 x8 x10 x1 DL = 10 psf DL = 0 psf No Attached Flexible Finish Brittle Finish Maximum Span 1,,3 Ceiling (including gypsum board) (including plaster and stucco) Rafter f b f b E 4 E 4 E 4 Spacing (psi) (psi) (psi) (psi) (psi) (ft-in.) (ft-in.) (ft-in.) (ft-in.) (ft-in.) 00 67 63,46 84,37 16,491 3-8 5-10 7-8 9-9 11-10 400 533 178,885 38,514 357,771 5-3 8-10 - 10 13-9 16-9 600 800 38,634 438,178 657,67 6-5 10-0 13-3 16-11 0-6 800 1,067 505,964 674,619 1,011,99 7-5 11-7 15-3 19-6 3-9 1,000 1,333 707,107 94,809 1,414,14 8-3 13-0 17-1 1-10 6-0* 1,00 1,600 99,516 1,39,355 1,859,03 9-0 14-18 - 9 3-11 6-0* 1,400 1,867 1,171,34 1,561,765,34,648 9-9 15-4 0-3 5-10 6-0* 1 in. 1,600,133 1,431,084 1,908,111,86,167 10-5 16-5 1-7 6-0* 6-0* 1,800,400 1,707,630,76,840 3,415,60 11-1 17-5 - 11 6-0* 6-0*,000,667,000,000,666,667 4,000,000 11-8 18-4 4-6-0* 6-0*,00,933,307,379 3,076,506 4,614,759 1-3 19-3 5-4 6-0* 6-0*,400 3,00,69,068 3,505,44 5,58,137 1-9 0-1 6-0* 6-0* 6-0*,600 3,467,964,456 3,95,608 5,98,91 13-4 0-11 6-0* 6-0* 6-0*,800 3,733 3,313,005 4,417,340 6,66,009 13-10 1-8 6-0* 6-0* 6-0* 3,000 4,000 3,674,35 4,898,979 7,348,469 14-3 - 5 6-0* 6-0* 6-0* 00 67 54,77 73,030 109,545 3-5 - 0 6-7 8-5 10-3 400 533 154,919 06,559 309,839 4-6 7-1 9-4 11-11 14-6 600 800 84,605 379,473 569,10 5-6 8-8 11-6 14-8 17-9 800 1,067 438,178 584,37 876,356 6-5 10-0 13-3 16-11 0-6 1,000 1,333 61,37 816,497 1,4,745 7-11 - 3 14-10 18-11 3-0 1,00 1,600 804,984 1,073,313 1,609,969 7-10 1-4 16-3 0-8 5-1,400 1,867 1,014,396 1,35,58,08,793 8-5 13-3 17-6 - 4 6-0* 16 in. 1,600,133 1,39,355 1,65,473,478,709 9-0 14-18 - 9 3-11 6-0* 1,800,400 1,478,851 1,971,801,957,70 9-7 15-1 19-10 5-4 6-0*,000,667 1,73,051,309,401 3,464,10 10-1 15-11 0-11 6-0* 6-0*,00,933 1,998,49,664,33 3,996,498 10-7 16-8 - 0 6-0* 6-0*,400 3,00,76,840 3,035,787 4,553,680 11-1 17-5 - 11 6-0* 6-0*,600 3,467,567,94 3,43,059 5,134,589 11-6 18-1 3-10 6-0* 6-0*,800 3,733,869,146 3,85,58 5,738,9 1-0 18-9 4-9 6-0* 6-0* 3,000 4,000 3,181,981 4,4,641 6,363,961 1-4 19-5 5-8 6-0* 6-0* 00 67 50,000 66,667 100,000-11 4-7 6-1 7-9 9-5 400 533 141,41 188,56 8,843 4-1 6-6 8-7 10-11 13-3 600 800 59,808 346,410 519,615 5-1 7-11 10-6 13-4 16-3 800 1,067 400,000 533,333 800,000 5-10 9-1 - 1 15-5 18-9 1,000 1,333 559,017 745,356 1,118,034 6-6 10-3 13-6 17-3 1-0 1,00 1,600 734,847 979,796 1,469,694 7-11 - 3 14-10 18-11 3-0 1,400 1,867 96,013 1,34,684 1,85,06 7-9 1-16 - 0 0-5 4-10 19. in. 1,600,133 1,131,371 1,508,494,6,74 8-3 13-0 17-1 1-10 6-0* 1,800,400 1,350,000 1,800,000,700,000 8-9 13-9 18-3 - 6-0*,000,667 1,581,139,108,185 3,16,78 9-3 14-6 19-1 4-5 6-0*,00,933 1,84,144,43,19 3,648,87 9-8 15-0 - 0 5-7 6-0*,400 3,00,078,461,771,81 4,156,9 10-1 15-11 0-11 6-0* 6-0*,600 3,467,343,608 3,14,811 4,687,17 10-6 16-6 1-9 6-0* 6-0*,800 3,733,619,160 3,49,14 5,38,30 10-11 17 - - 7 6-0* 6-0* 3,000 4,000,904,738 3,87,983 5,809,475 11-4 17-9 3-5 6-0* 6-0* 00 67 44,71 59,68 89,443-7 4-1 5-5 6-11 8-5 400 533 16,491 168,655 5,98 3-8 5-10 7-8 9-9 11-10 600 800 3,379 309,839 464,758 4-6 7-1 9-4 11-11 14-6 800 1,067 357,771 477,08 715,54 5-3 8-10 - 10 13-9 16-9 1,000 1,333 500,000 666,667 1,000,000 5-10 9-1 - 1 15-5 18-9 1,00 1,600 657,67 876,356 1,314,534 6-5 10-0 13-3 16-11 0-6 1,400 1,867 88,51 1,104,335 1,656,50 6-11 10-10 14-4 18-3 - 4 in. 1,600,133 1,011,99 1,349,38,03,858 7-5 11-7 15-3 19-6 3-9 1,800,400 1,07,477 1,609,969,414,953 7-10 1-4 16-3 0-8 5 -,000,667 1,414,14 1,885,618,88,47 8-3 13-0 17-1 1-10 6-0*,00,933 1,631,564,175,418 3,63,17 8-8 13-7 17-11 - 10 6-0*,400 3,00 1,859,03,478,709 3,718,064 9-0 14-18 - 9 3-11 6-0*,600 3,467,096,187,794,916 4,19,374 9-5 14-9 19-6 4-10 6-0*,800 3,733,34,648 3,13,531 4,685,96 9-9 15-4 0-3 5-10 6-0* 3,000 4,000,598,076 3,464,10 5,196,15 10-1 15-11 0-11 6-0* 6-0* * Spans (horizontal projection) are limited to 6 feet in length. Check sources for availability of lumber in lengths greater than 0 feet. See footnotes 1-4.

WOOD FRAME CONSTRUCTION MANUAL 97 Footnotes to Table.14A 1 Tabulated rafter spans assume ceiling joists or rafter ties are located at the bottom of the attic space to resist thrust. When ceiling joists or rafter ties are located higher in the attic space and are used to resist thrust, the rafter spans shall be reduced using the factors given in the following table: Ceiling Height/Top Plate to Roof Ridge Height (H C / H R ) 1/ 1/3 1/4 1/5 1/6 Rafter Span Adjustment Factors 1/7.5 and less 1.00 Note: Lateral deflection of the rafter below the rafter ties may exceed 3/4 inch when rafter ties are located above one third of the top plate to roof ridge height, H R, or when H c is greater than feet and may require additional consideration. 0.58 0.67 0.76 0.83 0.90 ENGINEERED DESIGN Tabulated rafter spans (horizontal projection) in Table.14A shall be permitted to be multiplied by the sloped roof adjustment factors in the following table for roof pitches greater than 4:1: Roof Pitch 8:1 10 psf Dead 0 psf Dead Adjustment Factor For Sloped Roofs 5:1 1.0 1.01 6:1 1.04 1.03 7:1 9:1 1:1 1.05 1.04 1.07 1.10 1.14 1.05 1.07 10:1 1.1 1.08 11:1 1.10 1.17 1.1 3 700 yr. Wind Speed 3 second gust (mph) 4' End Zone Interior Zone 4' End & Interior Zone Tabulated rafter spans (horizontal projection) in Table.14A are based on roof dead and live loads only. To determine the maximum rafter span from wind loading, multiply the span from Table.14A by the appropriate wind uplift load span adjustment factor from the tables below as well as by the rafter span adjustment factor for ceiling joist/rafter tie location from Footnote 1 and the appropriate sloped roof adjustment factor from Footnote. The wind load span shall not exceed the live and dead load span. RAFTER SPAN ADJUSTMENT FOR EXPOSURE B WIND LOADS Exposure B Roof Pitch 110 115 10 130 140 150 160 170 180 195 Factor to adjust Table.14A tabulated rafter spans (once adjusted per Footnotes 1 & as appropriate) 0:1 3:1 1.17 1.11 1.05 0.96 0.88 0.8 0.76 0.71 0.67 0.6 4:1 1.15 1.09 1.04 0.94 0.87 0.80 0.75 0.70 0.66 0.61 5:1 1.09 1.04 0.99 0.90 0.83 0.77 0.7 0.67 0.63 0.58 6:1 1.03 0.98 0.93 0.85 0.79 0.73 0.68 0.64 0.60 0.55 0:1 3:1 1.5 1.43 1.35 1. 1.1 1.03 0.96 0.89 0.84 0.77 4:1 1.47 1.39 1.31 1.19 1.09 1.00 0.93 0.87 0.8 0.75 5:1 1.39 1.3 1.5 1.13 1.04 0.96 0.89 0.83 0.78 0.71 6:1 1.31 1.4 1.18 1.07 0.98 0.91 0.84 0.79 0.74 0.68 7:1 1.5 1.43 1.35 1. 1.11 1.0 0.95 0.88 0.83 0.76 8:1 1.41 1.33 1.6 1.14 1.04 0.96 0.89 0.83 0.78 0.71 9:1 1.31 1.4 1.17 1.06 0.97 0.90 0.84 0.78 0.73 0.67 10:1 1. 1.15 1.09 0.99 0.91 0.84 0.78 0.73 0.69 0.63 11:1 1.13 1.07 1.0 0.93 0.85 0.79 0.73 0.68 0.64 0.59 1:1 1.05 1.00 0.95 0.86 0.79 0.73 0.68 0.64 0.60 0.55

COMMENTARY TO THE WOOD FRAME CONSTRUCTION MANUAL 41 Table.14A Rafter Spans for 0 psf Roof Live Load Description: Calculation of maximum permissible spans for lumber rafters. Procedure: Perform span calculation for a given set of E and f b properties. Adjust spans for rafter tie locations, roof pitch, and wind uplift. Background: Based on simple bending calculations, assuming the rafter is simply supported at each end. Span is assumed to be equal to the horizontal projection of the rafter. A more sophisticated approach would take the following into account: Compression stresses in a rafter when a ridge board replaces a ridge beam. Additional bending and compression load capacity provided by roof sheathing. Increased length of a sloped rafter relative to the horizontal projection. Reduced loads using a sloped rafter length relative to the horizontal projection. The magnitude of error introduced by ignoring additional compression is a function of load magnitude, span, and roof slope. Example: Given - x8 rafter, 16" o.c. rafter spacing, f b = 1,600 psi, 10 psf dead load, Δ LL < L/180 (no attached ceiling). L = 18 ft-9 in. (WFCM Table.14A) Calculate the modulus of elasticity required to limit live load deflection: 4 L 5wliveL = 180 384 EI E = ( ) = 5 ( 180) w 384I ( 5)( 180) live L 6 = 1. 39 x 10 psi E = 1.39 x 10 6 psi 3 6. 67 ( 4. 6) 1 384( 47. 63) 3 (WFCM Table.14A) Footnote 1: When ceiling joists are located higher in the attic space, the rafter span shall be reduced. Assuming the maximum moment occurs at the rafter tie location, the maximum applied moment is: M max = wlx wx / where: x = the horizontal distance from the edge of the top plate to the location of the rafter tie ENGINEERED DESIGN w dead = 10 psf(16 in./1) = 13.33 plf w live = 0 psf(16 in./1) = 6.67 plf w total = 3.33 + 6.67 = 40 plf Calculate the moment-limited span: f b wtotall 8S L = 8S( fb) w total 8 1314. ( 1, 600) = ( )( ) 40 / 1 = 5 in. = 18 ft 9 in. Based on similar triangles: x/h C = L/H R Substituting x into the equation and solving for maximum moment yields: M wl H L w C H L C max = H R H R The maximum tabulated moment is: M w L 8 maxtabulated =

COMMENTARY TO THE WOOD FRAME CONSTRUCTION MANUAL 43 The equation for horizontal deflections does not account for dead load contributions to deflection. The following amplification factor may be used to account for dead loads. ( DL + LL) A = LL Footnote 3: For rafters, the tabulated spans in Table.14A shall be adjusted for wind uplift loads. Adjustments for wind uplift loads shall be applied after adjustments are applied for Footnote 1 (for ceiling joist/rafter tie location), and Footnote (for roof pitch). Wind Uplift Dead Load Wind pressure, p, acts normal to the roof surface along the actual roof span. Since the horizontal projected span is used as the basis of the adjustments, the wind load is increased as follows in order to maintain the same effect: p = [-58.8 psf] / [(cos(6/1))(cos(6/1))] = 73.5 psf Adjusting for 16 in. rafter spacing: p = -73.5(16 in./1) = -98.0 plf Accounting for dead load: w DL = 10 psf(0.6)(16 in./1) = 8 plf Determining net uplift load: ENGINEERED DESIGN Rafter The following examples are shown for a rafter span adjustment factor for 150 mph Exposure B, 33' MRH, for the 4' End Zone, Interior Zone, and 4' End & Interior Zone, respectively for a x8 rafter, 16" o.c., f b = 1,600 psi, and 10 psf dead load. Components and cladding (C&C) wind exposure coefficients are used: Example for 4' End Zone (6:1 roof pitch): where: p = q(gc p - GC pi ) q = 1.15 psf GC p = -.6 (See Table C1.1) (ASCE 7-10 Figure 30.4-B) GC pi = +/-0.18 (internal pressure coefficient for enclosed buildings) = p - w DL = 98.0 plf 8 plf = 90.0 plf Load duration factors are used to account for the difference in roof live and wind loads. wtotall fb 8S L = = 8S( fb) w total., 16. ( ) 15. 90. 0 / 1 ( 8)( 1314)( 1 600) = 169. 4 in. = 14. 1 ft From Table.14A, the maximum tabulated rafter span is 18ft 9 in. or 18.75 ft. The adjustment factor for a 10psf dead load and 6:1 roof pitch is 1.04 per Footnote, therefore the adjusted rafter span is calculated as follows: Max. span = 18.75 ft (1.04) = 19.5 ft p = 1.15(-.6-0.18) psf = -58.8 psf (negative pressure denotes suction)

44 ENGINEERED DESIGN Dividing the maximum span for wind loading by the maximum span adjusted for roof slope: (14.1 ft) / (19.5 ft) = 0.7 (WFCM Table.14A Footnote 3 for 4' End Zone lists a multiplier of 0.73. The difference results from rounding in intermediate calculations.) Example for Interior Zone (6:1 roof pitch): where: p = q(gc p - GC pi ) q = 1.15 psf GC p = -1.7 GC pi = +/-0.18 p = 1.15(-1.7-0.18) psf (See Table C1.1) (ASCE 7-10 Figure 30.4-B) (internal pressure coefficient for enclosed buildings) = -39.8 psf (negative pressure denotes suction) Wind pressure, p, acts normal to the roof surface along the actual roof span. Since the horizontal projected span is used as the basis of the adjustments, the wind load is increased as follows in order to maintain the same effect: p = [-39.8 psf] / [(cos(6/1))(cos(6/1))] = -49.75 psf Adjusting for 16 in. rafter spacing: f b wtotall 8S L = = = 8S( fb) w total., 16. ( ) 15. 58. 331 / ( 8)( 1314)( 1 600) 10. 45 in. = 17. 5ft From Table.14A, the maximum tabulated rafter span is 18 ft 9 in. or 18.75 ft. The adjustment factor for a 10 psf dead load and 6:1 roof pitch is 1.04 per Footnote, therefore the adjusted rafter span is calculated as follows: Max. span = 18.75 ft (1.04) = 19.5 ft Dividing the maximum span for wind loading by the maximum span adjusted for roof slope: (17.5 ft) / (19.5 ft) = 0.90 (WFCM Table.14A Footnote 3 for Interior Zone lists a multiplier of 0.91. The difference results from rounding in intermediate calculations.) Example for 4' End & Interior Zone (10:1) roof pitch: p = -49.75(16 in./1) = -66.33 plf where: p = q(gc p - GC pi ) Accounting for dead load: q = 1.15 psf (See Table C1.1) w DL = 10 psf(0.6)(16 in./1) = 8 plf Determining net uplift load: = p - w DL = 66.33 plf 8 plf = 58.33 plf GC p = -1. (ASCE 7-10 Figure 30.4-C) GC pi = +/-0.18 (internal pressure coefficient for enclosed buildings) p = 1.15(-1.-0.18) psf = -9. psf (negative pressure denotes suction) Load duration factors are used to account for the difference in roof live and wind loads.

COMMENTARY TO THE WOOD FRAME CONSTRUCTION MANUAL 45 Wind pressure, p, acts normal to the roof surface along the actual roof span. Since the horizontal projected span is used as the basis of the adjustments, the wind load is increased as follows in order to maintain the same effect: p = [-9. psf] / [(cos(10/1))(cos(10/1))] = -49.48 psf Adjusting for 16 in. rafter spacing: p = -49.48(16 in./1) = -65.97 plf Accounting for dead load: w DL = 10 psf (0.6)(16 in./1) = 8 plf From Table.14A, the maximum tabulated rafter span is 18 ft 9 in. or 18.75 ft. The adjustment factor for a 10psf dead load and 10:1 roof pitch is 1.1 per Footnote, therefore the adjusted rafter span is calculated as follows: Max. span = 18.75 ft (1.1) = 1.0 ft Dividing the maximum span for wind loading by the maximum span adjusted for roof slope: (17.6 ft) / (1.0 ft) = 0.84 (WFCM Table.14A Footnote 3 for 4' End & Interior Zone ) ENGINEERED DESIGN Determining net uplift load: = p - w DL = 65.97 plf 8 plf = 57.97 plf Load duration factors are used to account for the difference in roof live and wind loads. wtotall fb 8S L = = = = 8S( fb) w total., 16. ( ) 15. 57. 97/ 1 ( 8)( 1314)( 1 600) 11. 10 in. 17. 6 ft