Pallet Safe: Installation Supplement Rev

Similar documents
SMARTSCAN INFORMATION 8000 SERIES PRODUCT GUIDE

SMARTSCAN 8000 SERIES MUTE MODULES Series Mute Accessories Installation Sheet ( CD174A and CD174B )

>Safety PRODUCT GUIDE

SECTION VEHICLE LIFTS. B. Section Basic Electrical Materials and Methods: Power and controls wiring.

TF20 Tray Feeder. Instruction Manual. for JEDEC and IEC Standard Trays

Saphyr System Safety Guide for Saphyr P/N 60325

INSULATION GUARD MEG (Code ) INSTRUCTION MANUAL ( M / 99A ) (c) CIRCUTOR S.A.

POWER FACTOR REGULATOR. Computer-12e-xx INSTRUCTION MANUAL ( M / 02A ) (c) CIRCUTOR S.A.

Application Report AS-Interface

WLC60 Heavy Duty LED Light

ISIMET. E Series Enclosure. Custom Assemblies Installation, Maintenance, and Operation Instructions

3 PHASE ENERGY ELECTRONIC METERS MKB-363-M INSTRUCTION MANUAL ( M / 00 B

SAFE STACK TURNERS AND LOGISTICS SYSTEMS IN THE PRINTING SECTOR

Quick Guide. CSN950 MultiHead Dimensioner _v2d_MAN_QG_CSN950MH_EN

OptoLum MegaLine RGBW Luminaire

XBDM-HW63. 63A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

MODEL NC405 MULTI-FUNCTION TOUCH-TONE* DECODER INSTRUCTION MANUAL

Continuous Wave Single Frequency Lasers. SYMPHONY Series. 532nm 2000mW

Model 3185E DUAL TONE DECODER INSTRUCTION MANUAL

MANUFACTURING TECHNICAL INSTRUCTIONS SAFETY Subject: DESIGN, MAINTENANCE AND INSPECTION OF SECONDARY ELECTRICAL DISTRIBUTION SYSTEMS

Precision Automatic Vacuum Control (PAVC+)

WLB32 Industrial LED Light Bar (DC)

Agilent Technologies SP50 Operator Mode Manual

RSD250 Unwind Dancer Package WEB CONTROL PRODUCTS FORM NO. L B User Manual. MTY (81)

MATERIAL SPECIFICATION FOR UNINTERRUPTIBLE POWER SUPPLY SYSTEMS FOR LED TRAFFIC SIGNALS

Continuous Wave Single Frequency Lasers. SCHERZO Series. 532nm 300mW

AUTOMATIC FOLDING DOOR

Conveyor Safe Operating Procedures

SUPPLY NETWORK ANALYZER CVM-SP SERIES INSTRUCTION MANUAL ( M / 01A

Stopwatch Display Timer Owner s Manual

MAN488 Issue 3 WBS/FBS MAINTENANCE BYPASSES AUTOMATIC VERSION

Multi-door Networking Controller

MODELS MB1K-1, MB1K-2 MB2K-1, MB2K-2 MB3K-1, MB3K-2

FIXED-WINDOW POWER DEMAND CONTROLLER BY ENERGY PULSES CVM-R8D-CPP INSTRUCTION MANUAL

DESCRIPTION. S-PAPI-1.3. Contractor shall be present and make adjustments as necessary during the FAA Flight Check. EQUIPMENT AND MATERIALS

Concepts that return a machine to a running state as quickly as possible after an interruption requiring maintenance or a demand on the safety system

Quick Guide. TLX Basic DWS System

FAST POWER FACTOR REGULATOR. Computer-14df - xx - 144a INSTRUCTION MANUAL ( M / 00A ) (c) CIRCUTOR S.A.

SafeDesign: Machine Safety Validation

10810 W. LITTLE YORK RD. #130 - HOUSTON, TX VOICE (713) FAX (713) web: IMPORTANT!!!

Gelovit 200 en English

Atlona VGA over CAT5 Extender w/stereo Audio and RS-232

SECTION ELECTRIC FOUR FOLD DOORS MODEL 46 FLAT SHEETED

Mechanical Ratings. Description Plastic (800EP/ES) Metal (800EM/EB) 1/2 cycle sine wave for 11 ms and no damage at 100 G

Delta Level 1000 Hinged Lip Pit Mounted & Suspended Frame Dock Leveller

SUGGESTED SPECIFICATION for Low Voltage (600V) Generator Paralleling Switchboard

Table of contents. 1. Introduction

Photoelectric Distance Sensors

Model 5200 Cargo Lift Installation and Operation Manual

Delta Part Liber Superthermic Insulated Bi-Folding Door. Product Data Sheet 7 / 4

k e e p t h e i r l o a d i n g d o c k s s a f e. T h a t s w h y w e v e d e v e l o p e d a

TallSlateTM Grandee Installation Manual

PROPOSAL: Q July 9, 2018

MTTC User Manual. Innovative Technology for a Connected World. General Description. Specifications and features

Guideline for Fire Safety. Elements of Solar. Photovoltaic Systems

1 HR 550FS Handwheel. 1.1 Handwheels

WP200e Wallbox to CD Changer Adapter

PD6770 VANTAGEVIEW LOOP-POWERED PROCESS METER

CM-v-3 module. GSM/GPRS/EDGE communication module for MT880 meters. Technical description

Xerox Nuvera Xerox Production Stacker Operator Manual

TM Wallbox Power Module HWI-WPM-6D VAC, 50/60Hz HWI-WPM-6D VAC, 50/60Hz

Design Your Safety System for Improved Uptime

SECTION SECURITY GRILLES 670 SERIES UPCOILING SECURITY GRILLE

SECTION FIELD PANELS

Ceiling Camera Lift 2015

PCB Mount VIA Soldering Guidelines

C60 Standby UPS. 800VA Models. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

110 mm 4.3. Description Salvo Glad Hand Lock

Guidelines for Solar Photovoltaic Installation

J1939 to NMEA2000 Adaptor Part Numbers: 3185 USER MANUAL

SECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how?

OWNER S MANUAL. Model 845. RFV Dye Marking System /15

SECTION 16496A MTS MANUAL TRANSFER SWITCH (MANUAL CONTROL ONLY) Note to Spec Writer: { } Denotes EATON Feature reference number

User s Manual. June 23, 2017 P/N Revision D. TURNER DESIGNS 1995 N. 1 st Street San Jose, CA Phone: (408) FAX: (408)

Anneal the element right on the spot

SECTION Coiling Doors and Grilles Model 4320

PD662 LOOP-POWERED METER Instruction Manual

USER MANUAL MODEL 1019 and 1019S DB-9 Async. Short Range Modem With Transformer Isolation

Drag Chain Conveyor Installation and Operation Manual

J60 Lithium Ion UPS 350VA Model User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

VIDEOTRONIK 2.0 CANBUS and RESISTIVE steering wheel commands adapter, Parking Sensor and climate control systems displaying

Original instructions JSNY7 Magnetic switch

Specification & Procurement Guide for Automatic Rising Bollards Model - VP100

Low Maintenance AC Powered Security Gate

DESIGNERS AND BUILDERS OF CURRENCY CHANGERS AND ALLIED SYSTEMS SINCE 1921 FOR RLC-2 / RLC-3. Manual Part No Revision No.

3. Dimensions, weights Placement and Assembly Statement of installations Electrical Components, Connection Diagrams...

Change-over and monitoring unit For medical locations acc. to DIN VDE 0100 Part 710

Intelligent Drivesystems, Worldwide Services. Decentralised inverters control cyclic operation and positioning DRIVESYSTEMS

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

Model 5000 Cargo Lift Installation and Operations Manual

PD662 LOOP-POWERED METER

SECTION Coiling Counter Shutters

IEC Functional Safety Assessment

Four Stacker Card Dispenser

Installation, Operation & Maintenance Manual

SECTION Coiling Counter Shutters

Omnicomm LLS 4 Fuel Level Sensors

HS-429 Vibration Trip Manual


A. Section includes busway and fittings including plug-in units.

Transcription:

Pallet Safe: Installation Supplement Rev. 4-1-13 Smartscan Incorporated, 33083 Eight Mile Road, Livonia MI 48152 Tel: (248)477-2900 Fax: (248) 477-7453 Web: www.smartscaninc.com

SMARTSCAN INCORPORATED Livonia, MICHIGAN Pallet Safe series The use of this document is reserved exclusively for the use of Smartscan Incorporated customers and personnel. The information and drawings contained herein are the sole property of Smartscan Incorporated, and shall not be disclosed to any third party without the prior written consent for Smartscan Incorporated. Smartscan Incorporated makes no warranty of any kind with regard to this material, including but not limited to, implied warranties or fitness for a particular purpose. The information in this document is subject to change without notice. Smartscan shall not be liable for any errors contained herein for incidental or consequential damages in connection with the performance of use of this material. In order for machinery to be guarded by the Smartscan Pallet safe light curtain system, the machinery must be capable of stopping at any point in the machine cycle. The guarded machine must be wired such that any interruption of the defined area will cause immediate arrest of the dangerous motion of the guarded machine. Smartscans Pallet Safe s ability to perform this function depends upon the appropriateness of the application and upon the Smartscan Pallets Safe s proper mechanical and electrical installation and interfacing to the machine being guarded. If all mounting, installation, interfacing and commissioning procedures are not followed properly the Smartscan Pallet Safe system cannot provide the protection for which it was designed. The user has the responsibility to ensure all local, state, national laws, rules, codes or regulations relating to the installation and use of this system in any particular application are satisfied. The user has the sole responsibility to ensure that the Smartscan Pallet Safe system is installed and interfaced to the guarded machine by qualified persons in accordance with this manual and applicable safety regulations. A qualified person is defined as a person or persons who, by possession of a degree or certificate of professional training, or who, by extensive knowledge, training and experience has successfully demonstrated the ability to solve problems relating to this subject matter and work (ANSI/AME B30.2-1983) www.smartscaninc.com 1

Curtain Mounting Considerations Light Curtain Orientation - Transmitter - Receiver Proximity to reflective surfaces Object d >d X Reflective surface X > 130 mm & X d /16 X is minimum distance between the light and the reflective surface. The closest distance of or to the object approaching the light curtain is d. Use with Mirrors Light Curtain Alignment 40 A 120 Range 20% per mirror A Y ± 2 X ± 2 Z ± 2 Optical Short Circuit Prevention Light Curtain Mounting IR 880 nm - 940 nm IR 800 nm-1000 nm Light curtain must be securely mounted such that the operator cannot reach the hazard without passing through the light curtain sensing region. The operator should not be able the reach over, reach under or walk past the protective devise without interrupting its sensing region. Additional guarding may be required to achieve this task. Warning: Do not repair or modify the Pallet Safe Light curtain. The Pallet Safe safety light curtain is not cite/field repairable and can only be repaired at the Smartscan. 2

Principle of Operation The Smartscan sensing unit consists of a transmitter and a receiver column that face each other across an area to be safeguarded. The transmitter contains a row of infrared, light emitting diodes that sequentially transmit parallel beams of energy to corresponding receiving diodes in the receiver column. When the control/monitoring unit detects an obstruction in the optical path of one, or more of the beams that form the sensing field, the output signal switching devices (OSSD s) will turn-off immediately. Receiver Transmitter Status Indictors Mute 1 (Yellow) mute sensor clear Blocked (Red) System Blocked Mute 2 (Yellow) mute sensor clear Clear (Green)- System Clear Diagnostic LED s Status (Yellow) Status relay open Mute (Yellow) System Muted Safety Relay OFF (Red) OSSD s OPEN Safety Relay ON (Green) OSSD s Closed Mute Enable (Red) Mute Enable ON EDM (Red) EDM ON Activate (Red) Activate ON Blue Indicator Lamp Diagnostic Indicators For diagnostic purposes visible red LED indicators adjacent to each infrared transmitting diode are provided, in the transmitter column. 3

Status Indicators The physical location of these indicators can be viewed on page 5. Guard clear indicator - A green LED indicator located in the top cluster of the receiver unit illuminates when the light curtain is clear of obstruction. Guard block indicator - A red LED indicator located in the top cluster of the receiver unit illuminates when the light curtain is blocked. Mute clear indicators Mute 1 and Mute 2 - Yellow LED indicators located in the top cluster of the receiver unit extinguish when mute sensors mute 1 and mute 2 are blocked. Mute condition on indicator - Yellow LED indicator located in the center cluster of the receiver unit illuminates when the light curtain output relays are in a muted condition. Status output indicator A Yellow LED indicator located in the center cluster of the receiver unit is illuminated when the status relay is de-energized, but extinguishes when the status relay energizes. Safe output on - A green LED indicator located in the bottom cluster of the receiver unit illuminates when the safe output switching relays are ON (Closed). Safe output off - A red LED indicator located in the bottom cluster of the receiver unit illuminates when the safe output switching relays are OFF (Open). Mute Enable on - A red LED indicator located in the bottom cluster of the receiver unit illuminates when the mute enable signal is applied. EDM on - A red LED indicator located in the bottom cluster of the receiver unit illuminates when the EDM circuit is complete. Activate on - A red LED indicator located in the bottom cluster of the receiver unit illuminates when the activate signal is applied. Indicator Lamp Indicator lamp is ON Solid when the light curtain is muted Indicator lamp is ON Solid when the light curtain is in Guard Override mode. 4

Pallet Safe Controls Qualified Persons Red Black +L = 24VDC@.5A 10% -L = 0VDC SHIELD A CABLE Connects to Transmitter column CLEAR BLOCKED OSSD s ON OSSD s OFF Orange Pink Turquoise The OSSD s can be series together by connecting the Pink & Turquoise wires. Gray SMM Out SMM In STATUS Green/ White Green Brown/ White or The SMM circuit should be connected together if a normally closed contact of the controls final switching device is not being monitored. MUTE OUTPUT Black/White Violet +L MUTE 1 MUTE 2 Yellow White -L -L Straight light curtains only Mute Enable Red/White -L Global mute enable Activate Heater Guard Override Blue Orange/White -L -L Activate key switch User supplied Guard Override Manual and Auto reset are defined by dip switches in column. Do not connect the activate wire in while in automatic restart mode Heater Brown +L RH systems ONLY Indicator Lamp ON when Muted or Guard Override 5

Pallet Safe Series: Controls Power supply - Use a regulated supply +24V DC, 1A ±10%. Protect the +24V input with a.5a fuse. Connect the power supply to cable B as follows: The RED wire to +24V DC and BLACK wire to 0V DC. Connect the shield to ground. EDM (External Device Monitoring) - This input is used to monitor external switching devices to ensure those devices respond each and every time the light curtain is interrupted. A red LED in the receiver column of the light curtain illuminates when the EDM circuit is complete. The EDM circuit must receive continuity to function properly; no external voltage should be applied. When monitoring a switching device one side of the Normally Closed circuit will connect to wire GREEN/WHITE wire (cable B), the other to wire GREEN. If the EDM function is not required connect wire GREEN/WHITE directly to wire GREEN otherwise the system will remain tripped and will not reset. Reset Modes: Dipswitches located in the horizontal section of the transmitter column controls the reset modes. There are two reset modes automatic reset and manual reset. Manual Start- A push button or key switch is recommended. Turning the activate switch to ON and then releasing the switch will restart the safety outputs (OSSD s) to an ON condition, providing the light curtain is clear of obstruction. If a PLC is used to manually reset the light curtain a minimum pulse width of 150 ms is required. Dipswitches in are in the OFF position. Activate: BLUE wire to 0V DC. Automatic Restart - No manual reset is needed; the light curtain restarts itself once the obstruction is cleared. The activate signal must be disconnected in this mode. Dipswitches in are in the ON position. Note: - The reset mode of the system is set upon initial power up. Power must be cycled to change from Automatic Restart Mode to Manual Restart Mode or visa-versa. Guard Override: Turning and holding the guard override switch in the ON state will automatically turn-on the safe output relay switching contacts for a period of 3 minutes, providing the light curtain is in a tripped condition e.g. with the curtain blocked by a loaded pallet. As soon as the loaded pallet clears the light curtain the safety system will automatically reactivate to a fully guarded condition. Now, release the guard override switch and restart the safety system in the normal manner. Blue indicator will turn ON solid when system is in Guard Override. Guard Override: ORANGE/WHITE wire to 0V DC. Use guard override when: (a) The reason for the blockage has been established (b) The light curtain is in view (c) No danger to any person can be caused. 6

Pallet Safe Series: Controls Safety Relay Outputs (OSSD s) These two safety outputs respond to interruption of the light curtain (unless muted). The relays close (ON) when the curtain is clear and open (OFF) when the curtain is blocked. They are cross-monitored voltage free contacts with a maximum contact switching power 110V, 2A. LED indicators located in the receiver column illuminate when the OSSD s are ON (green) or OFF (red). OSSD1 (Safety Output 1): ORANGE wire & PINK wire: OSSD2 (Safety Output 2): TURQUOISE wire & GRAY wire. Status Relay Output The status output is a voltage free NON-SAFETY contact that is ON (closed) when the safety relays are ON (closed) and OFF (open) when the safety relays are OFF (Open). The status contact has a maximum switching 110V, 1A. A yellow LED in the receiver column illuminates when the status output signal is OFF. Status Output: BROWN/WHITE wire & BLACK/WHITE wire Mute Output - Some machines require a mute signal to indicate that the light curtain is muted. To monitor the mute status of the light curtain the VIOLET wire (cable B) must receive 24V DC. This electronic output is rated 24VDC@100mA. A yellow LED in the receiver column illuminates when the mute output is ON. Mute Inputs (mute 1, mute 2). When both inputs are active ON within 2 seconds of each other, the light curtain will mute, e.g. the guard output switches will not respond to an interruption of the light curtain. There are also mute LED indicators located in the receiver column that extinguish when the mute signals are applied. If the mute inputs do not agree with in 2 seconds of each other the system will trip The blue indicator lamp located on the transmitter column will turn ON solid. Straight Light Curtains ONLY Mute 1: YELLOW wire to 0V DC. Mute 2: WHITE wire to 0V DC. External mutes Mute 1 & Mute 2 are only available in straight light curtains Mute enable input This signal must be applied for muting to occur. It may be used as a 3 rd mute signal. When self-muting light curtains are used on conveyor systems Conveyor Run can start the muting sequence. This technique makes deliberate bypass of the light curtain more difficult. A red LED in the receiver column illuminates when the mute enable signal is applied. Mute Enable: Connect RED/WHITE wire to 0V DC. Heater Units (only) The letters RH at the end of the part number designate heater units. These systems are typically used in freezer type applications and can be used in temperatures that do not extend below - 30 C = - 22 C. Heater (ON): Connect the BROWN wire (cable B) to +24Vdc 7

Pallet Safe Series: MUTING T Style To ensure correct operation of the safety system both mute beams must be interrupted by a loaded pallet within 2 seconds of each other and both must remain interrupted during the entire period the palletized load is transferring through the light curtain. Once both cross-beams are blocked the system will remain muted unit the product exits the cross beams. The cross-beam muting configuration is suitable for scanning a range between 1.25m and 3.5m. 8

Pallet Safe Series Muting: L Style System The L type module must NOT be used at infeed zones. To ensure correct operation of the safety system both mute beams must be interrupted by a loaded pallet within 2 seconds of each other and both must remain interrupted during the entire period the palletized load is transferring through the light curtain. Once both cross-beams are blocked the system will remain muted until the cross beams are cleared. There is a short period of time when the trailing edge of a pallet load clears the detection field of both mute sensors but is still interrupting the light curtain. A timer is incorporated within the safety control system that allows a period of 2 seconds between the pallet load clearing the mute sensors and clearing the light curtain. If the 2 second period is exceeded the safety system will trip. Suitably position the light curtain to ensure a pallet load does not stop after clearing the mute beams but still interrupting the light curtain. Top view of light curtain cable orientation (L1 or L2) B Cable Danger PALLET A Cable L Style Type 1 A Cable Danger PALLET L Module L Style Type 2 B Cable 9

Pallet Safe Series: Physical Set-up A Cable - Connects the transmitter (Tx) column to the receiver (Rx) column B Cable - This cable connects the light curtain to the user equipment e.g. control panel. At one end it has an 18 pin connector enabling it to be plugged into the receiver (Rx) and the other end has open (un-terminated) wires to connect to the control panel. B Cable Pin Out B Range Pallet Safe B Cable, Color Code Pin Color Function Signal I/O 1 Black -L Volts 0V DC 0VDC 2 Red +L Volts +24V DC +24V DC 3 Green EMD EDM Out Input 4 White Mute 2 Mute 2 input (Straight Only) Input 5 Brown Heater +24V DC to turn ON heater Input 6 Blue Activate Manual reset Input 7 Orange OSSD1 Safety Output 1 Output 8 Pink OSSD1 Safety Output 1 Output 9 Gray OSSD2 Safety Output 2 Input 10 Violet Mute Out Mute Output Output 11 Yellow Mute 1 Mute 1 input (Straight Only) Input 12 Brown/White Status Status Output (non-safety) Output 13 Orange/White G.O. Guard Override Input 14 Black/White Status Status Output (non-safety) Output 15 Red/ White Mute Enable Mute Enable Input 16 Shield Ground/Earth 17 Turquoise OSSD2 Safety Output 2 Input 18 Green/White EMD External Device Monitoring Input 10

Pallet Safe Series: Specifications Pallet Safe Series Light Curtains Number of beams 2 4 Object Detection 2, 3 & 4 beam systems Detection height 600, 900, and 1200mm Range Perimeter 0.5 40m (model dependent) Cross-beam muting 1.25 3.5m Light type IR 880nm Response time 40ms Operating temperature 0 C to +50 C (Heaters: -30 C to 25 C) Light curtain enclosure *IP54 Power supply 24V DC 0.5A 10% Current consumption 250mA Light curtain connection 18 pin Circular, bayonet locking connector Finish Aluminum chromate treated, yellow polyester powder coated Classification BS EN 61496-1 Type 2 BS IEC 61496-2 Type 2 BS EN 954-1 Category 3 IEC 62061 SIL 2 EN ISO 13849-1 PLd Warranty 1 Year OUTPUTS Safety Outputs OSSD1 & OSSD2 Status Output Relay Status Indication Mute Output 2 X N/O fail-safe switching contacts each rated at 110 V 2A 1 x N/O non-safety switching contact rated at 110V 1A Status & condition LED s on Light Curtain Electronic output. MUTE ON = 0V INPUTS Safety Monitoring (EDM) Connected GREEN/ WHITE to GREEN wire Activate Restart ON = 0V DC Guard Override Override ON = 0V DC Muting M1 and M2 Mute ON = 0V DC (Straight Only) Mute Enable 3 rd mute channel ON = 0V DC * For more information about IP ratings please contact Smartscan, inc. 11

Pallet Safe Series: Dimensions 61.5 61.5 31.5 Self-muting L Light Curtains Range 1.25 3.5m Model number Number of beams Detection Capability (mm) Centers (C) mm Overall length (O) mm Weight ( + ) Kg PS-903APL( 1 or 2) 3 440.4 958 969 4.2 PS-1204APL(1 or 2) 4 409.9 1263 1274 5.2 Self-muting T Light Curtains Range 1.25 3.5m Model number Number of beams Detection Capability (mm) Centers (C) mm Overall length (O) mm Weight ( + ) Kg PS-903APT 3 440.4 958 969 4.7 PS-1204APT 4 409.9 1263 1274 5.7 Straight Light Curtains Range 0.5 15m Model number Number of beams Detection Capability (mm) Centers (C) mm Centers (C) mm Overall length (O) mm Overall length mm Weight ( + ) Kg PS-903AP 3 440.4 958 1068 969 1079 3.7 PS-1204AP 4 409.9 1263 1373 1274 1384 4.7 Extended range straight lights available upon request. 12

Pallet Safe Series: Cables A Extension B Extension Model Number Description Overall length (L) m PSA05 Cable A 5m PSB05 Cable B 5m PSAX05 Extension (Cable A) 5m PSAX15 Extension (Cable A) 15m PSBX10 Extension (Cable B) 10m PSBX20 Extension (Cable B) 20m 13