TEX COTE 600 TEXTURED COATING MASONRY PROTECTIVE COATING

Similar documents
SECTION TEXTURED COATINGS. A. Section includes textured coating for tilt-up panels.

MDC MicroTex Eggshell Micro-Textured Ceramic Coating for Walls

MANUFACTURER S (SHORT FORM) SPECIFICATION / SECTION

MANUFACTURERS (SHORT FORM) SPECIFICATION / SECTION

ELASTOFLEX ELASTOMERIC TEXTURED ACRYLIC WALL COATING SPECIFICATION

This Section includes surface preparation and field application of anti-graffiti coating systems for the following vertical and horizontal surfaces:

A. Section includes surface preparation and the application of high-performance coating systems on the following substrates:

Union County Vocational - Technical Schools Scotch Plains, New Jersey

RENEW ELASTOMERIC ACRYLIC COATING (PAINT GRADE) MANUFACTURERS SPECIFICATION / SECTION

RD COATINGS -RD-ELASTOFLEX ELASTOMERIC ACRYLIC WALL COATING SPECIFICATION

SECTION (09941) - TEXTURED FINISHING

ARDEX GUIDE SPECIFICATION ARDEX CD Concrete Dressing and ARDEX CD FINE Concrete Dressing Polymer-Modified, Portland Cement-Based, Resurfacing Compound

A. Section includes surface preparation and application of wood finishes[.]

SECTION MULTICOLOR INTERIOR FINISHING

POLYURETHANE FOAM SAMPLE DESIGN GUIDELINES URETHANE

MONOBASE AAC/ SIDER-PLAST THE ULTIMATE EXTERIOR HARD COAT STUCCO SYSTEM FOR AUTOCLAVED AERATED CONCRETE

POLYURETHANE FOAM SAMPLE DESIGN GUIDELINE ACRYLIC

SPECIFIER SHALL REMOVE COMMENTS IN BOLD TEXT PRIOR TO SUBMITTING.

ERSYSTEMS ONESTEP PLUS

A. Supplier Qualifications: The ACRYSHIELD SPF Roofing System, as supplied by National Coatings Corporation, is approved for use on the project.

SECTION POLYPROPYLENE FABRIC WALL COVERING

RECOMMENDED DESIGN SPECIFICATION

SOLAR COATING SYSTEMS ACRYLIC RENOVATION ROOF 4.5. Specification for Built-Up Roofing SUMMARY

SECTION EPOXY RESIN FLOORING WITH INTEGRAL COVE BASE

Acrylitex Interior Texture and Coating Submittal Documentation

DRYVIT SYSTEMS, INC. MANUFACTURER'S SPECIFICATIONS CSI MASTERFORMAT SECTION WEATHERLAST WATERPROOFING PRODUCTS

SECTION EPOXY RESIN FLOORING WITH INTEGRAL COVE BASE

Protective Industrial Polymers - USA Manufacturer s Specification February 11, 2015

Stamped Asphalt Generic Specification

SIDER-BASE CONCENTRATE AAC/ MONOSIDERAL AAC THE ULTIMATE OLD-WORLD AERATED CONCRETE-AAC DECORATIVE STUCCO SYSTEM

PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960

SECTION RESINOUS FLOORING

Elastomeric Protected Membrane Roofing Fluid-Applied Protected Membrane Roofing. Restoration Coating System (RCS) over Cap Sheet

APPLICATION GUIDELINE

Pacific Polymers Elasto-Deck 5000X2 Guide Specification

1.04 REFERENCES STANDARDS.1 For reference standards tests & results refer to Manufactures Product Data Sheets

SECTION EPOXY RESIN FLOORING WITH INTEGRAL COVE BASE

Application Instructions for Dryvit Backstop NT For Use Beneath Claddings Other Than Dryvit EIFS

ROOFING APPLICATION STANDARD (RAS) No. 109

Specifications. Specifications (Architectual) Metallic System. Metallic System

Sample Specification

Section COATING RESTORATION

SECTION INSTALLATION AND/OR REPLACEMENT OF MASONRY UNITS AND REPOINTING

SECTION High Performance Coatings Field Applied Acrylic Urethanes (Solid Color, Pearl and Metallic Finishes)

Guideline Specification ACRYMAX ARS-1-C Reinforced Composite Elastomeric Membrane System for Concrete Roofs Fluid-Applied Roofing

80201R StoColor Acryl Flat Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

ROOFING APPLICATION STANDARD (RAS) No. 109

PERM-FLEX (JC) ASSEMBLY DIRECT APPLICATION TO CEMENT BOARD SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960

POLYACRYLATE MODIFIED THINSET TERRAZZO 1

1.02 SUMMARY A. Section Includes: 1. Repair of two-coat historic exterior vertical plasterwork (stucco)

Section COATING RESTORATION

APPLICATION GUIDELINE Recoating Spray Foam Acrylic System

SECTION WOOD WINDOWS

B. Samples: Submit, for verification purposes, samples of the following:

PRODUCT GUIDE SPECIFICATION

SECTION CONCRETE AND MASONRY COATINGS

GEOGARD LO Base Coat / GEOGARD Finish Coat

Pacific Polymers Elasto-Deck 5000MR Guide Specification

SAMPLE SPECIFICATION

SECTION FLUID-APPLIED WATERPROOFING

ZONE 7 WATER AGENCY CWS 5 TURNOUT REPLACEMENT PROJECT # ADDENDUM NO. 3 April 02, 2019

BAYBLOCK HT/BAYBLOCK HT BASE

SOLAR COATING SYSTEMS SYSTEM EMULSION /ACRYLIC. Specification for Built-Up Roofing MULSION/A 1.01 SUMMARY

Magna Wall. Elastomeric Coatings (Non-Textured) Product Overview, Instructions, & Data

ARDEX GUIDE SPECIFICATION ARDEX MC RAPID One-Coat Moisture Control System For Concrete to Receive ARDEX ARDIFLO Pump System Underlayments

SECTION Arisfor WallGuard

Insulating Concrete Form (ICF) Texture Finish

SKIMM /DUROFLOAT A High Performance Filling Compound For Interior Walls DST301. SKIMM / DUROFLOAT Specifications

FLUID APPLIED WATERPROOFING

1/16 Single Broadcast Polymer Flooring System

Gensler 2014/06/16 Hertz Global Headquarters ISSUE FOR BUILDING PERMIT Estero, Florida SECTION

ASH GROVE KOLORSTONE BROOMCOAT MIXING KIT. Spec Sheets Contents: Kolorstone Broomcoat Mixing Spec Sheet Kolorflex Admixture Spec Sheet

CUSTOM BRICK. Custom Brick Finish Polymer System Specifications For Use On Vertical Walls DS151. Architectural Finish for Use on Vertical Walls

80212R StoColor Lastic Acrylic-Based, Elastomeric Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

ACRYLIC. AGED (PVC, CPE, CPA) SINGLE-PLY (Thermoplastic) Membrane Restoration Sample Design Guideline

CUSTOM BRICK. Custom Brick Finish Polymer System Specifications For Use On Vertical Walls DS151. Architectural Finish for Use on Vertical Walls

SECTION VINYL-COATED FABRIC WALL COVERINGS

BENEFITS & ADVANTAGES:

A. Submit product data sheets and literature verifying fire ratings and physical properties of materials.

80648R StoCoat Acryl Plus Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

Associated Spec Consultants, Inc. February 27, 2014 SECTION ARCHITECTURAL COATINGS

Terra Cotta Glaze Repair System

80657R StoColor Texture Fine Textured Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

80657R StoColor Texture Fine Textured Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

SECTION mil thickness COLD FLUID-APPLIED WATERPROOFING

***********************************************************************************

80648R StoColor Acryl Plus Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

TOPCOAT Restoration Specifications Structural Concrete

Ger-Eck, LLC SCRIBIL Dry Erase Clear Coat Section July 12, 2013 SECTION SCRIBIL Dry Erase Clear Coat

80230 StoColor Coat Sand Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for New Concrete, Stucco, and Masonry Construction

Dist. by: BEST MATERIALS Ph:

ReCote Finish System over Concrete

CARLISLE DECK COATING INSTALLATION OVER EXISTING POLYURETHANE COATINGS

ACRYLIC Elastek #127 Solar One Plus

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DISTRIBUTION EQUIPMENT

SECTION INTUMESCENT FIREPROOFING

Kolorines Glass Mosaic Tiles Project Specification

ReflectiClean Acrylic/Urethane

Pacific Polymers Elasto-Deck BT Guide Specification

Transcription:

SECTION 09960 - TEXTURED COATINGS Coating System Submittals Guide Specification TEX COTE 600 TEXTURED COATING MASONRY PROTECTIVE COATING (SPLIT FACE OR SAND FINISH BLOCK) 1. TEX COTE 600, Textured Coating - A high build 100% acrylic terpolymer (water base) coating with elastomeric properties featuring rapid drying and adhesion. This coating is recommended over dense block and/or CMU systems. Masonry surfaces must cure a minimum of 28 days prior to coating. 1. Product data: Submit manufacturer's technical information including label analysis and application instructions for each material proposed for use. 2. Wall Sample: a. General: For each system specified, provide eight (8) foot by eight (8) foot wall sample for Architect's approval prior to beginning Project application of each TEXTURED coating system. 3. Manufacturer's recommended application procedures which, when approved by Architect, will become the basis for accepting or rejecting actual application procedures used on the Work. Delivery and Storage 1. Lids must be kept tightly sealed. Do not allow moisture to enter containers. 2. Store containers in a dry place, upright and airtight at temperatures of forty-five (45 F) degrees F. and not exceeding one hundred (100 F) degrees F. Skins formed on surface of material must be removed prior to moving containers, mixing or using. Job Conditions 1. Apply coating only when temperature of surfaces to be coated and surrounding air temperatures are between forty-five (45 F) degrees F. and one hundred (100 F) degrees F., unless otherwise permitted by manufacturer's printed instruction. 2. Do not apply over frozen or wet surfaces, or when rain is imminent. TEXTURED COATINGS 09960 1/6

Warranty Products 3. Incompatible substrate release agents, form oils, and any foreign material should be removed prior to priming and coating. 4. Roof and parapet top caps are installed and sealed against water penetration prior to priming and coating. 5. Primer or block filler shall not be exposed to ultra violet for more than four (4) weeks prior to application of coating. If exposure exceeds four (4) weeks, primer shall be re-coated. 6. Material use is above grade only. Do not use below grade. 7. Joint Sealants must cure a minimum of ten (10) days or per manufacturer s recommentdation. Excess sealant surface oils should be removed with a acetone solvent or approved cleanser. 1. On completion, in accordance with manufacturer's current written specifications, provide Owner with manufacturer's written "Limited Warranty" for product replacement. Acceptable Manufacturers Locations: Textured Coatings of America, Inc. 2422 East 15th Street Panama City, Florida 32405-6348 (850) 769-0347 Textured Coatings of America, Inc. 4101 Ravenswood Road, Suite 218 Fort Lauderdale, Florida 33312 (954) 581-0771 Textured Coatings of America, Inc. 5950 S. Avalon Blvd. Los Angeles, CA 90003 (323) 233-3111 TEXTURED COATINGS 09960 2/6

Materials Equipment Coating System: 1. TEX COTE 600 Textured Coating 2. Textures: As selected by Owner/Architect 3. Colors: To be selected by Owner/Architect 4. Primer: TEX COTE XL-70 Slush Cote or TEX COTE Latex Block Filler 5. Coating System Performance: a. Twin Arc Weatherometer (Hours) - 5,000 b. Federal Test TT-C-555b - Passes c. Freeze/Thaw Cycles - 300 d. Flame Spread Rating ASTM - E84 - Class A e. Wind-Driven Rain Test (98 MPH/24 Hours) - Passes f. Salt Spray Test ASTM B-117 64 (Hours) - 300 g. Alkali Resistance GSA Exception #1 to TT-C-555b - Passes TEX COTE 600 Textured Coating and TEX COTE XL-70 Slush Cote: Execution Inspection 1. Spray Equipment: Graco President 10:01 Pump with Graco 204-000 Spray Gun or Graco Tex-Spray GM 1030. 1. Applicator must examine areas and conditions under which TEXTURED coating work is to be applied and notify Contractor in writing of conditions detrimental to proper and timely completion of work. Do not proceed with work until satisfactory conditions have been corrected in a manner acceptable to applicator. a. Starting of TEXTURED coating will be construed as applicator's acceptance of surfaces and conditions within any particular area. TEXTURED COATINGS 09960 3/6

Surface Preparation 1. General: Perform preparation and cleaning procedures in accordance with coating system manufacturer's instructions and as herein specified, for each particular substrate and coating condition. a. Remove hardware, hardware accessories, machined surfaces, plates, lighting fixtures and similar items in place and not be finish coated, or provide surface applied protection prior to surface preparation and coating operations. Remove, if necessary, for complete coating of items and adjacent surfaces. Following completion of coating of each area, reinstall removed items. b. All surfaces shall be sound, clean, dry and cured a minimum of twentyeight days prior to the application of primer and coatings. Such surface contaminants as dust, dirt, mildew, form oils, loose substrate, etc., shall be removed. Excessive form oils, release agents and curing compounds may require a light sandblasting. c. Large cracks, holes and voids must be filled with cement patching compound and TCA Tex-Bond cement adhesive. Texture of patch shall match texture of existing surface. 1. Remove all loose material from area. 2. Vee out cracks. 3. Dampen areas with water. 4. Apply with brush, spray or roller to areas being patched. 5. Over dampened surface, using suitable tool such as a trowel, apply stucco or cement patching containing Tex-Bond in proper mix proportions as recommended by manufacturer. d. Cracks over one-sixteenth (1/16) inch and no greater than one-eighth (1/8) inch shall be filled with Flex-Patch patching compound. 1. Fine surface cracks shall be veed out prior to application of Flex-Patch. Surface must be clean and dry. 2. Stir Flex-Patch thoroughly before using. Do not thin. TEXTURED COATINGS 09960 4/6

Coating System Guide Specification 3. Use wide, broad knife for application over smooth surfaces. If rough stipple is required, use a short bristle brush. 4. Cure a minimum of forty-eight (48) hours before coating. e. Prior to the application of primer or coating, all existing areas should be examined and determined to be a sound, tightly bonded surface. Areas unsound, not tightly bonded should be repaired according to proper installation procedures. All joints and openings shall be sealed and roof shall be installed and sealed. f. Mask all glass, shrubbery and asphalt surfaces. 1. Interfacing wall joints shall be filled with two part urethane type sealant. 2. Over clean, dry surface apply primer per manufacturer's printed technical data. Materials Preparation Application 1. Mix and prepare coating materials in accordance with manufacturer's directions. 2. Store materials not in actual use in tightly covered containers. Maintain containers used in storage, mixing and application of coatings in a clean condition, free of foreign materials and residue. 3. Stir materials before application to product a mixture of uniform density, and stir into material. Remove film and if necessary, strain material before using. 1. Apply coating in accordance with manufacturer's directions. Use applicators and techniques best suited for substrate and type of material being applied. 2. Coating System: a. Apply XL-70 Slush Cote or TEX COTE Latex Block Filler at the manufacturer s specified coverage rate ensuring material is broomed or brushed into the pores of the block or CMU. TEXTURED COATINGS 09960 5/6

b. Material should be applied in a pinhole-free, continuous film over the entire surface to be coated. c. Over primed, clean, dry surface apply TEX COTE 600 with full coverage rate in desired texture and color with recommended spray equipment. d. Application of TEX COTE 600 shall be at a uniform film thickness over entire surface being covered. e. A wet edge shall be maintained at all times during spraying to prevent lapmarks, and that edge shall be feathered or fogged out widely. f. If applicator must stop mid-wall at end of day, an area up to four (4) feet wide should be fogged in. 3. Avoid starting and stopping midway on wall. Continue to a natural break such as a panel edge or corner. 4. On large areas, two (2) workers spraying simultaneously is recommended to avoid lapmarks and spray patterns. Cleaning and Protection 1. General: a. Clean-up: During progress of work, remove from site discarded coating materials, rubbish, cans and rags at end of each work day. b. Upon completion of coating work, clean window glass and other coating splattered surfaces. Protect work of other trades, whether to be coated or not, against damage by coating and finishing work. Correct any damage by cleaning, repairing or replacing, and recoating, as acceptable to Architect. c. Provide "wet paint" signs as required to protect newly-coated finishes. Remove temporary protective wrappings provided by others for protection of their work, after completion of coating operations. d. At the completion of work of other trades, touch-up and restore all damaged or defaced surfaces. TEXTURED COATINGS 09960 6/6

tc600gs.doc\10-98 TEXTURED COATINGS 09960 7/6